elero Antriebstechnik 285XX0901 RC System for rolling shutters / awnings and venetian blinds User Manual Combio 915 120 V USA CA Combio 915 USA 11 05
elero GmbH Antriebstechnik RC System for rolling shutters / awnings and venetian blinds Combio 915 120 V USA CA Combio 915 USA 11 05
Contents
- 1. User Manual
- 2. User Manual Annex
User Manual
Combio-915/120 V Combio-915 JA 285000906 Combio-915 RM 285200906 elero Bedienungsanleitung Bitte bewahren Sie die Bedienungsanleitung auf ! Operating Instructions Please keep the instructions in a safe place. PT Instrucciones de servicio ¡Por favor, conserve estas instrucciones de servicio! PT Instruções de serviço Por favor conserve as instruções em lugar seguro. elero GmbH Antriebstechnik Linsenhofer Str. 59–63 D-72660 Beuren Tel.: +49 (0) 7025-13-01 Fax: +49 (0) 7025-13-212 www.elero.com info@elero.de 181106606/0510 EN/ES/PT Safety tips USA CA Contents Safety tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . USA/CA- 2 Important safety indications! Observe the following Instructions. General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . USA/CA- 3 Use in accordance with the regulations . . . . . . . . . . . USA/CA- 3 Optimal use of the radio signal . . . . . . . . . . . . . . . . . USA/CA- 4 Mounting options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . USA/CA- 5 Combio-915 JA for venetian blind drives . . . . . . USA/CA- 6 Combio-915 RM for tubular motors . . . . . . . . . . . USA/CA- 7 Connection and installation . . . . . . . . . . . . . . . . . . . . . . USA/CA- 8 Combio-915 JA for venetian blind drives . . . . . . USA/CA- 8 The Combio-915 RM for elero tubular motors with plug-in cable (limit switch drive) . . . . . . . . . . USA/CA- 9 Combio-915 RM for tubular motors with plug-in cable (ACS-E electronic drive). . . . . . . . . USA/CA-10 Warning! Danger of injury due to electric shocks. Connections to the 120 V mains supply must be carried out by authorized, specialized personnel. • Check the installations regularly for wear and tear or damage. • The regulations stipulated by the local power supply company should be observed during connection work, as well as the regulations for wet and damp areas in accordance with NFPA. • Observe country-specific regulations. • Only use unaltered elero original parts. Combio-915 RM for tubular motors with fixed cable (limit switch drive) . . . . . . . . . . . . USA/CA-11 Combio-915 RM for elero tubular motors with fixed cable (CSM-E electronic drive) for textile sun protection. . . . . . . . . . . . . . . . . . . . . . . USA/CA-12 • Ensure that nobody is within the vicinity of the installation until it is brought to a standstill. • When carrying out work on the installation (e.g. maintenance), always disconnect the installation from the mains supply. Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . USA/CA-13 • Keep children away from controls. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . USA/CA-13 • The control unit must be installed so that it is not exposed to rain. EC-Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . USA/CA-14 USA/CA-1 USA/CA-2 regulations Optimal use of the radio signal USA CA General/Use in accordance with the General information Optimal use of the radio signal The Combio-915 JA/RM radio receiver allows the extension of alternating current drives to a radio drive. • Do not bend the antenna. Use in accordance with the regulations • If reception is poor, adjust the antenna. The Combio-915 JA/RM can only be used for controlling roller shutters and sun protection systems such as venetian blinds. • Install the antenna so that it is as exposed as possible. • Please observe that radio equipment cannot be operated in areas with a high interference risk level (e.g. hospitals, airports). • Using a number of receivers may cause interference. • The remote control is only allowed for devices and installations in which a malfunction in the hand-held transmitter or the receiver does not represent a threat to persons, animals or things or for installations in which this risk is excluded by other safety systems. • Do not shorten or extend the antenna. • Antenna is not to rest on metal. Note: Radio installations which transmit with the same frequency can cause reception interferences. Please observe that the radio signal range is restricted by the legislator and structural measures. • The user does not have any protection from interferences from other telecommunication and terminal equipment (e.g. including radio equipment which is operated in accordance with the corresponding regulations in the same frequency range). • Connect radio receivers only to the devices and installations authorized by the manufacturer. USA/CA-3 USA/CA-4 Combio-915 JA Mounting options Combio-915 JA for venetian blind drives (28 500.0001) Combio-915 JA 1. Put the Combio-915 into the mounting clamp. Combio with clip 2. Fasten the Combio-915 JA + clamp to the inside or outside of the channel. USA CA Mounting options The Combio-915 JA is suitable for the use with venetian blind drives. In order to carry out an exact slat tilting, the Combio-915 JA has a dead-man operating mode. If the button on the hand-held transmitter is pressed until the LED goes out, the receiver activates the self-locking operating mode. The handheld transmitter can be used to save an intermediate position and tilting position for the slats (D refer to the transmitter instructions). Antenna Combio with clip inner Combio with clip outer Drive Mounting options Mains 230 V/50 Hz N PE Combio-915 RM Combio-915 JA 1. Stick the enclosed adhesive strip onto the Combio-915 RM. Note: Do not shorten or lengthen the antenna. Combio with clip USA/CA-5 USA/CA-6 Connection and installation (Combio-915 JA) Combio-915 RM for tubular motors (28 520.0001) Combio-915 JA for venetian blind drives The Combio-915 is suitable for the use with tubular motors for roller shutters and sun protection systems. If a command is sent, the receiver immediately activates the selflocking operating mode. The hand-held transmitter can be used to program an intermediate position. For sun protection systems it is possible to additionally program a fabric tautening and a ventilation position for roller shutters (D refer to the transmitter instructions). 1. Put the drive into operation with the installation cable and set the upper and lower limit switch. 2. Move the hangings with the installation cable to an intermediate position. 3. Switch off the mains voltage. 4. Unplug the installation cable. 5. Connect the female Hirschmann-plug of the radio receiver with the drive plug. 6. Connect the Hirschmann-plug of the radio receiver with the female plug of the mains cable. Antenna Drive Mains 230 V/50 Hz N USA CA Combio-915 RM 1~ 1 2 3 Combio-915 RM Antenna PE Pin designation PE Wire colour Brown Blue Green/yellow Note: Do not shorten or lengthen the antenna. USA/CA-7 Mains 230 V/50 Hz N PE Combio-915 JA 7. Fasten the radio receiver. 8. Switch the mains voltage on again. 9. Programme the transmitter (D refer to the transmitter instructions). USA/CA-8 Connection and installation (Combio-915 The Combio-915 RM for elero tubular motors with plug-in cable (limit switch drive) Combio-915 RM for tubular motors with plug-in cable (ACS-E electronic drive) 1. Switch off the mains voltage. 1. Switch off the mains voltage. 2. Press the locking mechanism of the drive plug towards the cable with a screwdriver. 3. Pull out the plug. 3. Pull out the plug. 4. Plug the motor cable of the radio receiver into the drive. 5. Connect the mains cable of the Combio-915 RM correctly with the mains voltage. 1~ Mains 230 V/50 Hz N Combio-915 RM Wire colour Brown Blue Green/yellow 6. Fasten the radio receiver. 7. Switch the mains voltage on again. 8. Programme the transmitter (D refer to the transmitter instructions). 9. Mount the hangings and set the limit switch. USA/CA-9 4. Plug the motor cable of the radio receiver into the drive. 5. Connect the mains cable of the Combio-915 RM correctly with the mains voltage. 1~ Antenna PE Pin designation PE 2. Press the locking mechanism of the drive plug towards the cable with a screwdriver. Mains 230 V/50 Hz PE Antenna Combio-915 RM Pin designation PE Wire colour Brown Blue Green/yellow 6. Fasten the radio receiver. 7. Switch the mains voltage on again. 8. Programme the transmitter (D refer to the transmitter instructions). Note: Rotate the winding shaft manually in the corresponding direction. 9. Mount the hangings and operate the drive in the self-programming mode. USA/CA-10 USA CA Connection and installation (Combio-915 RM) Connection and installation (Combio-915 RM for CSM-E) Combio-915 RM for tubular motors with fixed cable (limit switch drive) Combio-915 RM for elero tubular motors with fixed cable (CSM-E electronic drive) for textile sun protection. 1. Switch off the mains voltage. Note: CSM-E drives must not be connected using the connector located on the Combio-915 RM. 2. Cut off the plug of the radio receiver. 3. Prepare the cable for connection (remove cable jacket and strip). 4. Connect the motor cable of the drive and the cable of the Combio-915 RM correctly (connect the same colours). 5. Connect the mains cable of the Combio-915 RM correctly with the mains voltage. PE br. bl. 1~ Pin designation B/V V/B PE Wire colour Pin designation PE Wire colour Brown Black Blue Green/yellow 1. Put the drive into operation with the installation cable (programme the end positions). 2. Move the hangings with the installation cable to an intermediate position. 3. Switch off the mains voltage. 4. Disconnect the installation cable. 5. Cut off the plug of the radio receiver. 6. Prepare the cable for connection (remove cable jacket and strip). 7. Connect the motor cable of the drive and the cable of the Combio-915 RM correctly (connect the same colours). 8. Connect the mains cable of the Combio-915 RM correctly with the mains voltage. Antenna PE Combio-915 RM PE br. bl. Mains 230 V/50 Hz 1~ Brown Blue Green/yellow 6. Fasten the radio receiver. 7. Switch the mains voltage on again. 8. Programme the transmitter (D refer to the transmitter instructions). 9. Mount the hangings and set the limit switch, provided that the limit switches have not already been set using the installation cable. USA/CA-11 Antenna Mains 230 V/50 Hz PE Combio-915 RM Pin designation B/V V/B PE Wire colour Pin designation PE Wire colour Brown Black Blue Green/yellow Brown Blue Green/yellow 10. Fasten the radio receiver. 11. Switch the mains voltage on again. 12. Programme the transmitter (D refer to the transmitter instructions). USA/CA-12 USA CA Connection and installation (Combio-915 RM) Technical data EC-Declaration of conformity E C - D E C LARAT I O N O F C O N F O R M I T Y Combio-915 JA Combio-915 RM (venetian blind drives) (tubular motors) Nominal voltage 120 V 120 V Frequency 60 Hz 60 Hz Max. 450 W 450 W Protection class IP 54 IP 54 Permitted ambient temperature –20 to +80°C Radio frequency –20 to +80°C 915 MHz frequency band Mains cable 0,5 m with Hirschmann plug 3m Motor cable 0,25 m with 0,25 m with Hirschmann female plug plug Dimensions in mm L 100 x B 44 x H 15 L 100 x B 44 x H 15 Max. number of transmitters 16 We hereby declare that the following mentioned product/s meet/s the standards of the European Community. Product designation: ProLine x Combio-868/ -915/ -433 all versions x VarioTec-868 /-915 all versions x Revio-868 all versions x AeroControl-868 x UniLogic-868/ -915 Description: Radio receiver for controlling roller shutters, blinds and other shading systems The conformity of the above mentioned products with the relevant requirements is approved by the following directives and standards: 16 Troubleshooting Problem Cause Solution No radio reception 1. Transmitter is 1. Program the not programmed. transmitter. 2. No mains 2. Switch on the mains voltage. supply again. Bad radio reception Unsuitable receiver Change the location of position. the receiver or the antenna. Inverted sense Sense are program- Delete transmitter and of rotation med incorrectly. program correctly. USA/CA-13 EMC Directive 2004/108/EC EN 60335-1, EN 61000-6-2, EN 61000-6-3, EN 61000-4-5 Low Voltage Directive 2006/95/EC EN 61000-4-4, EN 61000-4-2 EN 61000-4-11, EN 61000-4-5 R&TTE-Directives 1999/5/EC ETSI EN 301 489-3 V1.4.1 ETSI EN 300 220-3 V2.3.1 DIN EN 60730-1 (VDE 0631 part 1); EN 30730-1 +A1 +A2 +A11 bis A17 DIN EN 60730-2-7 (VDE 0631 part 2-7); EN 60730-2-7 +A1 +A11 +A12 +A13 +A14 Beuren, 29.12.2009 Ulrich Seeker – CE Officer – – Representative – elero GmbH Antriebstechnik Linsenhofer Str. 59–63 D-72660 Beuren USA/CA-14 USA CA Technical data/Troubleshooting
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 8 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Creator Tool : QuarkXPress 7.31 Create Date : 2010:05:20 14:46:46+02:00 Modify Date : 2010:05:20 14:46:46+02:00 Title : Combio-915/120 V USA/CA:Combio-915 USA 11.05 Creator : G5_Protype Producer : Acrobat Distiller 9.3.2 (Macintosh) Author : G5_ProtypeEXIF Metadata provided by EXIF.tools