iControl Networks SMCTB01Z Zigbee Alarm Takeover Module User Manual SMCMT02 Z Motion Sensor Quick Start Guide

iControl Networks, Inc. Zigbee Alarm Takeover Module SMCMT02 Z Motion Sensor Quick Start Guide

User manual

Download: iControl Networks SMCTB01Z Zigbee Alarm Takeover Module User Manual SMCMT02 Z Motion Sensor Quick Start Guide
Mirror Download [FCC.gov]iControl Networks SMCTB01Z Zigbee Alarm Takeover Module User Manual SMCMT02 Z Motion Sensor Quick Start Guide
Document ID1431749
Application IDcCRcLCntM11dGSIJfsUclQ==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize13.47kB (168359 bits)
Date Submitted2011-03-15 00:00:00
Date Available2011-09-11 00:00:00
Creation Date2011-03-09 13:13:59
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2011-03-09 13:14:47
Document TitleSMCMT02-Z Motion Sensor Quick Start Guide
Document CreatorAcrobat PDFMaker 9.1 for Word
Document Author: SMC Networks

iControl OpenHome™ Converge Panel Interface
Quick Start Guide
Congratulations on purchasing your Panel Interface.
The iControl Networks, Inc. OpenHome Converge Panel Interface is a professional state-of-the-art device that allows you to manage your
Honeywell Vista 20P system and sensors from your TouchScreen.
For UL/ETL applications:
•
•
The Panel Interface module MUST be located
behind the Vista 20P keypad and installed
within an industry standard PVC box. This box
must be designed and listed for use with nonmetallic sheathed cable in accordance with
Article 314 of the National Electrical Code®.
All boxes must be listed to UL514C. This box is
not provided as part of the installation kit. It
must be provided by the installer.
Note: If 10 seconds have passed with no key entry, the
keypad automatically exits address mode. You must power
down, power up and start address mode again.
B. Remove AC power and the red and flying leads from the battery
located in the Vista 20P alarm panel.
C. Remove the existing Vista20P keypad(s) from the mounting surface.
D. Cut the cable that connects the Vista 20P keypad to the alarm
panel using care to not allow the wire coming from the alarm panel
to fall back into the wall.
The Panel Interface module must be installed in the same room as
the alarm control panel and keypad.
Installation Guidelines
Important: The Panel Interface module must be installed at least 0.3
inches (0.8 cm) away from any metal structure and be used at
distances of more than 8 inches (20 cm) away from the user.
A. Prior to installation of the Panel Interface module, each Vista 20P
keypad must be programmed to unique keypad address of 16-23, or
to the non-addressable mode (31).
Do the following to change the address of the Vista 20P keypad:
1. Enter address mode.
2. Power up the keypad.
3. Within 60 seconds of power-up, press and hold down the [1]
and [3] keys at the same time for 3 seconds.
E. Strip cable ends and attach the cut ends of the cable to the
iControl Panel Interface as illustrated.
Note: If unable to enter the Address mode, power up and try
again.
The current keypad address is displayed. The cursor is under the
tens digit.
Connect cable wires based on their color as in the diagram above.
The wire colors identify their functions:
Panel Interface Quick Start Guide
•
•
•
•
Yellow
Green
Red
Black
Transmit from key pad to panel
Transmit from panel to key pad
A/C power from the panel to
the key pad
K. When the Vista 20P alarm panel is powered, the Panel interface(s)
are in search mode and ready to be paired with the Touchscreen.
Note: If the LED on a Panel Interface does not blink three
times each five seconds, there is a possibility that the Panel
Interface must be reset to factory default. See section 3.
F. Snap the Panel Interface into a
industry-standard PVC box (not
included) and attach the box to the
mounting surface.
Technical Details
Physical Dimensions
Device
G. If the existing Vista 20P keypad was
not mounted on an approved
recessed electrical enclosure box,
then use the included Panel
Interface plastic holder as a guide
to cut a recess opening to mount
the device.
Height
Width
Depth
Printed circuit
board assembly
(PCBA)
1-7/8 in (4.8 cm)
2-3/4 in (7 cm)
½ in (1.3 cm)
PCBA in holder
2 in (5.1 cm)
2-3/4 in (7 cm)
7/8 in (2.2 cm)
Voltage
12VDC (power-limited)
H. Reattach the Vista20P
Current
I. Repeat each of the
LED Status
85mA (LED lit)
keypad to the
mounting surface.
above steps for each
Panel Interface.
Remember one
Interface is required
for each operational
Vista 20P keypad.
Condition
Description
On solid
Panel Interface is in boot-up mode.
Blinking
Panel Interface is in locate mode and can
be paired with the TouchScreen.
Off
Normal operation
J. Return AC power and then the red and black flying lead from the
battery located in the Vista 20P alarm panel.
261-00016-60
02/11
Rev A
©
Copyright 2011 iControl Networks
All Rights Reserved
Page | 2
Panel Interface Quick Start Guide
on the keypad to restart the process or cycle power to the Panel
Interface.
Setting the Panel Interface to Factory
Default
Perform the following steps within 10 minutes of power-up to set the
Panel Interface to factory default.
F. Touch Next, and the system scans the premises for Panel Interfaces
that can be added, which must meet the following requirements:
- Defaulted
- Not currently paired with another TouchScreen.
- In Search Mode (LED blinking 3 times every 5 seconds)
A. Press and hold the [1] and [*] keys at the same time until the
keypad beeps.
B. Press and hold the [3] and [#] keys at the same time until the
keypad beeps.
G. Follow the system prompts to complete the add process and pair
the key pad with the TouchScreen.
C. Press and hold the [1] and [*] keys at the same time until the
Note: If no available Panel Interfaces are found, tap Done to
return to the Technician Settings menu without adding.
keypad beeps.
D. Press and hold the [3] and [#] keys at the same time until the
keypad beeps.
The keypad should then display either “Welcome to uControl SMA” or
“iControl OpenHome.” If so, the Panel Interface has been defaulted.
H. When all the Panel Interfaces are found, tap Next. The
TouchScreen begins locating the Zones connected to the Panel
system. This operation can take a few minutes. When all the zones
are found, an icon for each is displayed in the Configure Panel
Interface Sensors screen.
I. Tap a Zone icon to configure the following:
Adding a Panel Interface
A. From the TouchScreen Home screen, tap the Settings app.
B. When the TouchScreen Keypad screen appears, tap the numbers to
enter the Installer keypad code (this code is the same for all
TouchScreens installed by your company).
Display icon (such as a window or door icon)
Zone Function (Entry/Exit, Perimeter, or 24-Hour Inform)
Zone Label (a user-defined identifier for the zone)
J. After all the zones are configured, tap Next.
C. When the Technician keyboard pad appears, enter your Technician
ID and touch Done.
D. When the Technician Settings menu appears, tap Home Devices.
The Home Devices menu appears.
E. Tap Panel Interface > Add Panel Interface Boards. The Locating
Congratulations!
You have successfully added your panel interfaces. The Vista
20P system key pad can now be used to enter key pad codes
to disarm the iControl OpenHome Converge system during
Entry delay. Additionally, the key pad information screen
displays messages from the iControl system.
Key Pads screen appears.
The Panel Interface can be located only within the first 90 seconds
of being powered up. The Alarm Panel Alphanumeric Keypad should
be displaying “Scanning for Network.” If not, then press any button
261-00016-60
02/11
Rev A
©
Copyright 2011 iControl Networks
All Rights Reserved
Page | 3
Panel Interface Quick Start Guide
Compliances
Deleting a Panel Interface
Deleting a panel interface from the premises removes all the zones
connected to the associated panel system.
To delete a panel interface from the TouchScreen:
A. Perform steps A through D in step 2, “Adding a Key Pad to the
TouchScreen”.
B. When the Technician Settings menu appears, select Panel
Interface > Delete Panel Interface Boards. The Remove Panel
Interface Boards and Zones screen appears.
C. Tap Next. A confirmation dialog is displayed that says “Are you
sure you want to remove all panel interface boards and zones?
D. Tap Yes.
The all the panel interface boards added to the system are deleted.
Additionally, all zones connected to the Vista 20P are also removed
from the iControl environment.
Bypassing Zones
The exterior of the device should be labeled with the following
instructions “Zigbee Panel Interface is integrated with “Contains FCC
ID: Y6Q-SMCTB01Z” and “Contains IC ID 9454A-SMCTB01Z”.
This device complies with Part 15 of the FCC rules. Operation of this
device is subject to the following two conditions:
1) This device may not cause harmful interference, and
The “IC” designation preceding the radio certification number indicates
that this device complies with the Industry of Canada specifications.
Limitations of Security Products
A. Enter your user code.
B. Press Bypass (or 6, if there is no dedicated bypass key).
C. Press the two-digit zone number.
Security products and alarm systems do not offer guaranteed
protection against burglary, fire, or other emergencies. They may fail
to warn for diverse reasons, including (but not limited to): power
failure, dead batteries, improper installation, coverage, coverage areas
overlooked during installation, defeat by technically sophisticated
intruders, component failure, or inadequate maintenance. Alarm
systems should be checked weekly to ensure that all devices are
working properly.
uControl, Inc.
Model: SMCTB01Z
FCC ID Y6Q- SMCTB01Z
IC: 9454A-SMCTB01Z
02/11
This device has been designed, constructed, and tested for compliance
with FCC Rules that regulate intentional and unintentional radiators. As
the user of this device, you are not permitted to make any alterations
or modifications to this equipment or to use it in any way that is
inconsistent with the information described in this quick-start guide,
without the express written permission of SMC Networks. Doing so will
void your warranty to operate this equipment.
2) This device must accept any interference received, including
interference that may cause undesired operation.
To use the Honeywell keypad to bypass a zone:
261-00016-60
FCC No tic e
AN ALARM SYSTEM IS NOT A SUBSTITUTE FOR INSURANCE
Rev A
©
Copyright 2011 iControl Networks
All Rights Reserved
Page | 4
Panel Interface Quick Start Guide

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : SMC Networks
Company                         : Microsoft
Create Date                     : 2011:03:09 13:13:59-06:00
Modify Date                     : 2011:03:09 13:14:47-06:00
Source Modified                 : D:20110309190909
Subject                         : 
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2011:03:09 13:14:47-06:00
Creator Tool                    : Acrobat PDFMaker 9.1 for Word
Document ID                     : uuid:c4b75d14-751d-4f61-99fa-6fbe2540861b
Instance ID                     : uuid:34713862-0158-414c-b0ba-c94f2119b70f
Format                          : application/pdf
Title                           : SMCMT02-Z Motion Sensor Quick Start Guide
Description                     : 
Creator                         : SMC Networks
Producer                        : Adobe PDF Library 9.0
Keywords                        : 
Page Layout                     : OneColumn
Page Count                      : 5
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Y6Q-SMCTB01Z

Navigation menu