u blox San Diego LISAC200A CDMA 1xRTT Cellular Module User Manual
u-blox San Diego, Inc. CDMA 1xRTT Cellular Module Users Manual
Contents
- 1. Users Manual
- 2. Host Unit Manual
Users Manual
CDMA 1xRTT Wireless Modules System Integration Manual Abstract This document describes the features and the integration of u-blox LISA-C200 and FW75-C200 CDMA2000 1xRTT wireless modules. These modules are complete and cost efficient CDMA solutions offering 153 kb/s data speed dual-band 800/1900 MHz data transmission technology in compact form factors. www.u-blox.com locate, communicate, accelerate LISA-C200 & FW75-C200 LISA-C200 & FW75-C200 - System Integration Manual Document Information Title LISA-C200 & FW75-C200 Subtitle CDMA 1xRTT Wireless Modules Document type System Integration Manual Document number CDMA-2X-11004-3 Document status Preliminary Document status information This document contains target values. Revised and supplementary data will be published Objective Specification later. This document contains data based on early testing. Revised and supplementary data will Advance Information be published later. Preliminary This document contains data from product verification. Revised and supplementary data may be published later. Released This document contains the final product specification. This document applies to the following products: Name Type number Firmware version PCN / IN LISA-C200 LISA-C200 FW75-C200 FW75-C200 LISA-C200-01S LISA-C200-21S FW-C200-01S FW-C200-21S E0.S.03.00.10R E0.V.03.00.02R E0.S.03.00.10R E0.V.03.00.02R UBX-TN-12041 UBX-TN-12041 UBX-TN-12041 UBX-TN-12041 This document and the use of any information contained therein, is subject to the acceptance of the u-blox terms and conditions. They can be downloaded from www.u-blox.com. u-blox makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to mak e changes to specifications and product descriptions at any time without notice. u-blox reserves all rights to this document and the information contained herein. Reproduction, use or disclosure to third parties without express permission is strictly prohibited. Copyright © 2012, u-blox AG. ® u-blox is a registered trademark of u-blox Holding AG in the EU and other countries. CDMA-2X-11004-3 Page 2 of 43 LISA-C200 & FW75-C200 - System Integration Manual Preface u-blox Technical Documentation As part of our commitment to customer support, u-blox maintains an extensive volume of technical documentation for our products. In addition to our product-specific technical data sheets, the following manuals are available to assist u-blox customers in product design and development. AT Commands Manual: This document provides the description of the supported AT commands by the LISA-C200 & FW75-C200 module to verify all implemented functionalities. System Integration Manual: This Manual provides hardware design instructions and information on how to set up production and final product tests. Application Note: document provides general design instructions and information that applies to all u-blox Wireless modules. See Section Related documents for a list of Application Notes related to your Wireless Module. How to use this Manual The LISA-C200 & FW75-C200 System Integration Manual provides the necessary information to successfully design in and configure these u-blox wireless modules. This manual has a modular structure. It is not necessary to read it from the beginning to the end. The following symbols are used to highlight important information within the manual: An index finger points out key information pertaining to module integration and performance. A warning symbol indicates actions that could negatively impact or damage the module. Questions. If you have any questions about u-blox Wireless Integration, please: Read this manual carefully. Contact our information service on the homepage http://www.u-blox.com Read the questions and answers on our FAQ database on the homepage http://www.u-blox.com Technical Support Worldwide Web Our website (www.u-blox.com) is a rich pool of information. Product information, technical documents and helpful FAQ can be accessed 24h a day. By E-mail Contact the nearest Technical Support office by email. Use our service pool email addresses rather than any personal email address of our staff. This makes sure that your request is processed as soon as possible. You will find the contact details at the end of the document. Helpful Information when Contacting Technical Support When contacting Technical Support please have the following information ready: Module type (e.g. LISA-C200) and firmware version Module configuration Clear description of your question or the problem A short description of the application Your complete contact details CDMA-2X-11004-3 Preliminary Preface Page 3 of 43 LISA-C200 & FW75-C200 - System Integration Manual Contents Preface ................................................................................................................................3 Contents..............................................................................................................................4 System description .......................................................................................................6 1.1 Overview .............................................................................................................................................. 6 Architecture.......................................................................................................................................... 7 1.2 Functional blocks........................................................................................................................... 7 1.2.1 1.3 Pin description ...................................................................................................................................... 8 1.4 Power management ........................................................................................................................... 10 1.4.1 Power supply circuit overview ...................................................................................................... 10 1.4.2 Module supply (VCC) .................................................................................................................. 11 1.4.3 Current consumption profiles ...................................................................................................... 17 System functions ................................................................................................................................ 18 1.5 1.5.1 Module power on ....................................................................................................................... 18 1.5.2 Module power off ....................................................................................................................... 20 1.5.3 Module reset ............................................................................................................................... 20 1.6 RF connection ..................................................................................................................................... 20 Serial communication ......................................................................................................................... 21 1.7 Serial interfaces configuration ..................................................................................................... 21 1.7.1 1.7.2 Asynchronous serial interface (UART)........................................................................................... 22 USB interface............................................................................................................................... 24 1.7.3 1.7.4 MUX Protocol (3GPP 27.010) ...................................................................................................... 25 1.8 Reserved pins (RSVD) .......................................................................................................................... 25 Schematic for LISA-C200 and FW75-C200 modules integration ......................................................... 26 1.9 Approvals........................................................................................................................................ 27 1.10 1.10.1 Declaration of Conformity for products marked with the FCC logo - United States only .............. 27 1.10.2 Modifications .............................................................................................................................. 27 Design-In .....................................................................................................................28 2.1 Design-in checklist .............................................................................................................................. 28 2.1.1 Schematic checklist ..................................................................................................................... 28 2.1.2 Antenna checklist ........................................................................................................................ 28 2.2 Connectors (FW75) ............................................................................................................................. 29 2.2.1 FW75-C200 modem connector ................................................................................................... 29 FW75-C200 Board to Board host connector ................................................................................ 29 2.2.2 FW75-C200 RF antenna connector.............................................................................................. 30 2.2.3 2.3 Design Guidelines ............................................................................................................................... 31 2.3.1 Layout guidelines per pin function ............................................................................................... 31 2.4 Antenna guidelines ............................................................................................................................. 32 2.4.1 Antenna termination ................................................................................................................... 33 CDMA-2X-11004-3 Preliminary Contents Page 4 of 43 LISA-C200 & FW75-C200 - System Integration Manual 2.4.2 Antenna radiation ....................................................................................................................... 34 ESD immunity test precautions ........................................................................................................... 35 2.5 General precautions .................................................................................................................... 36 2.5.1 2.5.2 Antenna interface precautions..................................................................................................... 37 2.5.3 Module interfaces precautions..................................................................................................... 38 Features description...................................................................................................39 3.1 3.2 3.3 Firmware (upgrade) Over The Air (FOTA.............................................................................................. 39 UDP/IP ................................................................................................................................................ 39 HTTP................................................................................................................................................... 39 Appendix ..........................................................................................................................40 A Glossary ......................................................................................................................40 Related documents...........................................................................................................42 Revision history ................................................................................................................42 Contact ..............................................................................................................................43 CDMA-2X-11004-3 Preliminary Contents Page 5 of 43 LISA-C200 & FW75-C200 - System Integration Manual 1 System description 1.1 Overview u-blox C200 wireless modules integrate a complete CDMA 1xRTT 153 kb/s packet data modem into a single module solution. These modems are certified to operate on US CDMA carriers. In addition they can operate on carriers requiring a SIM data card interface. 3G CDMA 2000 1xRTT Characteristics CDMA Terrestrial Radio Access Frequency Division Duplex (FDD) operating mode Dual-band support: Band Class 0 – US Cellular Band Class 1 – US PCS CDMA Packet Switched data up to 153 kb/s DL/UL Table 1: 3G CDMA 2000 1xRTT characteristics These modems are US CDMA certified to support 1xRTT data speeds on US CDMA carriers Sprint and Verizon. FW75-C200 is strictly a data modem for embedded solutions while LISA-C200 also supports audio (analog and digital) functionality. Data communication is through 2 data interfaces; 5 wires UART and Full Speed USB. The interfaces are intended to support a vast quantity of AT commands that will enable easy adoption to existing host application processors. Power on is initiated by HW logic and Power down by HW logic and SW control. LISA-C200 antenna interface is provided through a 50 ohm pad while FW75-C200 uses the popular “U.FL” RF connector. Other key components are the extensive SW AT commands meeting the needs of : Carrier AT commands Industry standard AT command both 3GPP and 3GPP2 u-blox AT Commands CDMA-2X-11004-3 Preliminary System description Page 6 of 43 LISA-C200 & FW75-C200 - System Integration Manual 1.2 Architecture ANT Digital and analog voice (**) Diplexer RF Transceiver UART 3G PA 19.2 MHz 3G PA LNA SAW Filter 32.768 kHz Wireless Base-band Processor USB GPIOs (**) LNA Memory Power On Vcc (Supply) Power Management Unit HW shutdown (*) HW Reset (**) V_INT (I/O) (*): FW75 (**): LISA-C200 Figure 1: Block diagram 1.2.1 Functional blocks LISA-C200 & FW75-C200 modules consist of the following internal functional blocks: RF front-end, RF transceiver, Baseband section and Power Management Unit. RF Front-End The Antenna connector is directly connected to the Diplexer which separates the 800 and 1900 MHZ bands. Each 800 & 1900 MHz RF chain are connected to their respective transceiver paths via duplexers as shown in prior block diagram. Each duplexer provides the filtering and Rx/Tx path separation before connecting to the LNA and RF PA devices. A separate shield compartment houses the 800 MHZ and 1900 MHZ RF power amplifiers. This compartment provides high Tx signal isolation, preventing de-sensing of the Rx frontend circuitry. RF Transceiver The transceiver includes the following key components: Dual-band 800 & 1900 MHz CDMA transceiver, excluding the RF Power Amplifiers, duplexers and diplexer. 19.2 MHz Crystal Oscillator While operating, the RF transceiver performs direct up-conversion and down-conversion of the baseband I/Q signals, with the RF voltage controlled gain amplifier being used to set the uplink TX power. In the downlink path, the internal LNA enhances the RX sensitivity. An internal automatic gain control amplifier optimizes the signal levels before delivering to the analog I/Q to baseband for further digital processing. CDMA-2X-11004-3 Preliminary System description Page 7 of 43 LISA-C200 & FW75-C200 - System Integration Manual In all the modes, Tx & Rx RF synthesizers are an on-chip voltage controlled oscillator are used to generate the local oscillator signal. The frequency reference to RF synthesizers are provided by a free running 19.2 MHz XO. The Rx path locks and tracks to the base station carrier. An learning algorithm is implemented to capture the temperature characteristic of the xtal, comparing the XO and carrier frequencies, while measuring the thermistor in close proximity to the crystal oscillator. A lookup table is saved over temperature and time. The known frequency difference of the free running crystal oscillator is corrected in the baseband processor enabling quick acquisition. Baseband section and power management unit Another shielding section includes all the digital circuitry and the power supplies, basically the following functional blocks: Wireless baseband processor, a mixed signal ASIC which integrates: Microprocessor for controller functions, CDMA upper layer software ARM9 coprocessor and HW accelerator for CDMA Layer 1 control software and routines Dedicated HW for peripherals control, as UART, USB, etc Memory system in a Multi-Chip Package (MCP) integrating two devices: NOR flash non-volatile memory DDR SRAM volatile memory Power Management Unit (PMU), used to derive all the system supply voltages from the module supply VCC 1.3 Pin description Table 2 provides a summary of the module pin names and descriptions. For the exact specification including pin numbering and additional information see the LISA-C200 Data Sheet [1] or the FW75-C200 Data Sheet [2]. Name Module Power domain I/O Description Remarks VCC All VCC Module supply Module supply input V_INT FW75-C200 Digital I/O Interfaces supply output LISA-C200 Digital I/O Interfaces supply output V_INT = 2.85V (typical) generated by the module when it is switched-on and the RESET_N (external reset input pin) is not forced to the low level. V_INT = 1.8V (typical) generated by the module when it is switched-on and the RESET_N (external reset input pin) is not forced to the low level. PWR_ON All POS Power-on input PWR_ON pin has Internal pull-up resistor. GPIO1..10 LISA-C200 GDI I/O GPIO GPIO6..10 Reserved. RESET_N LISA-C200 ERS External reset input RESET_N pin has Internal pull-up resistor. HW_SHUTDOWN FW75-C200 ERS External Shutdown input HW_SHUTDOWN pin has Internal pull-up resistor. ANT All ANT I/O RF antenna STATUS FW75-C200 GDI LED Indicator Indicated by buffered External LED : Off – Not Powered On – Powered, associated, and authenticated but not transmitting or receiving. Slow Blink but not associated or authenticated; searching. Intermittent Blink - activity proportional to transmitting/receiving speed. For voice applications, turning off and on the intermittent blink based on the ring pulse cycle can indicate a ring event. CDMA-2X-11004-3 Preliminary System description Page 8 of 43 LISA-C200 & FW75-C200 - System Integration Manual Name Module RI Power domain GDI I/O Description Remarks UART ring indicator Circuit 125 (RI) in ITU-T V.24. Value at internal reset: T/PU. Use to wake up host processor. The output signal is active low. Internal active pull-up to 1.8 V. Internal active pull-up to 2.85 V GDI UART clear to send Circuit 106 (CTS) in ITU-T V.24. Internal active pull-up to 1.8 V. Internal active pull-up to 2.85 V. GDI UART ready to send GDI UART received data GDI UART transmitted data Circuit 105 (RTS) in ITU-T V.24. Internal passive pull-up to 1.8 V. Internal passive pull-up to 2.85 V. Circuit 104 (RxD) in ITU-T V.24. Internal active pull-up to 1.8 V. Internal active pull-up to 2.85 V. Circuit 103 (TxD) in ITU-T V.24. Internal passive pull-up to 1.8 V. Internal passive pull-up to 2.85 V. LISA-C200 FW75-C200 CTS LISA-C200 FW75-C200 RTS LISA-C200 FW75-C200 RXD LISA-C200 FW75-C200 TXD LISA-C200 FW75-C200 VUSB_DET All USB USB detect input Input for VBUS (5 V typical) USB supply sense. USB_D- All USB I/O USB Data Line D- 90 Ω nominal differential impedance. Pull-up or pull-down resistors and external series resistors as required by the USB 2.0 high-speed specification [9] are part of the USB pad driver and need not be provided externally. USB_D+ All USB I/O USB Data Line D+ 90 Ω nominal differential impedance. Pull-up or pull-down resistors and external series resistors as required by the USB 2.0 high-speed specification [9] are part of the USB pad driver and need not be provided externally. MIC_N LISA-C200 AUDIO Differential analog audio input (negative) MIC_P LISA-C200 AUDIO Differential analog audio input (positive) Differential analog microphone input. Internal DC blocking 0.1 µF capacitor. Differential analog microphone input. Internal DC blocking 0.1 µF capacitor. SPK_P LISA-C200 AUDIO Differential analog audio output (positive) SPK_N LISA-C200 AUDIO Differential analog audio output (negative) PCM_SYNC LISA-C200 GDI Digital Sync Differential analog audio output shared for all path modes: earpiece, headset and loudspeaker mode. Differential analog audio output shared for all path modes: earpiece, headset and loudspeaker mode. Digital Audio Sync pulse. PCM_DO LISA-C200 GDI Data Output Digital Audio Output. PCM_CLK LISA-C200 GDI Clock Output Digital Audio Clock Output. PCM_DI LISA-C200 GDI Data Input SCL LISA-C200 DDC I C bus clock line SDA LISA-C200 DDC I/O I2C bus data line SIM_CLK All SIM SIM clock SIM_IO All SIM I/O SIM data SIM_RST All SIM SIM reset VSIM ALL SIM supply output SIM_GND FW75-C200 SIM SIM GROUND RSVD All RSVD RESERVED pin Unless otherwise specified, leave unconnected. GND All GND Ground All GND pads must be connected to ground. Digital Audio Input. Fixed open drain. No internal pull-up. Value at internal reset: T. Fixed open drain. No internal pull-up. Value at internal reset: T. Value at internal reset: L. Internal 4.7 kΩ pull-up resistor to VSIM. Value at internal reset: L/PD. Value at internal reset: L. 1.80 V typical or 2.90 V typical generated by the module according to the SIM card type. Table 2: Pin description summary CDMA-2X-11004-3 Preliminary System description Page 9 of 43 LISA-C200 & FW75-C200 - System Integration Manual 1.4 Power management 1.4.1 Power supply circuit overview LISA-C200 & FW75-C200 modules feature a power management concept optimized for the most efficient use of supplied power. This is achieved by hardware design utilizing a power efficient circuit topology (Figure 2), and by power management software controlling the module’s power saving mode. 2 x 3G Power Amplifier(s) u-blox C200 Memory NOR Flash RF Transceiver DDR SRAM Linear LDO VCC Linear LDO EBU Switching Step-Down I/O Switching Step-Down CORE Linear LDO Analog Linear LDO SIM Linear LDO RTC 42 µF VCC VCC Power Management Unit Baseband Processor V_INT VSIM 4.7 µF 2.2 µF Figure 2: Power management simplified block diagram Pins with supply function are reported in Table 3. LISA-C200 & FW75-C200 modules must be supplied via the VCC pins. There is only one main power supply input, available on the three1 or five2 VCC pins that must be all connected to the external power supply LISA-C200. CDMA-2X-11004-3 Preliminary System description Page 10 of 43 LISA-C200 & FW75-C200 - System Integration Manual The VCC pins are directly connected to the RF power amplifiers and to the integrated Power Management Unit (PMU) within the module: all supply voltages needed by the module are generated from the VCC supply by integrated voltage regulators. When a 1.8 V or a 3 V SIM card type is connected, LISA-C200 & FW75-C200 modules automatically supply the SIM card via the VSIM pin. Activation and deactivation of the SIM interface with automatic voltage switch from 1.8 to 3 V is implemented, in accordance to the ISO-IEC 7816-3 specifications. The 2.8 voltage domain used internally also available on the V_INT pin, to allow more economical and efficient integration of the LISA-C200 & FW75-C200 modules in the final application. The integrated Power Management Unit also provides the control state machine for system start up and system shut down control. 1.4.2 Module supply (VCC) LISA-C200 & FW75-C200 modules must be supplied through the VCC pins by a DC power supply. Voltages must be stable: during operation, the current drawn from VCC can vary by some orders of magnitude. Name Description Remarks VCC Module power supply input VCC pins are internally connected, but all the available pads or pins must be connected to the external supply in order to minimize the power loss due to series resistance. Clean and stable supply is required: low ripple and low voltage drop must be guaranteed. Voltage provided must always be above the minimum limit of the operating range. GND Ground GND pins are internally connected but a good (low impedance) external ground can improve RF performance: all available pads or pins must be connected to ground. Table 3: Module supply pins Higher ESD protection level can be required if VCC is externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin. The voltage provided to the VCC pins must be within the normal operating range limits as specified in the LISA-C200 Data Sheet [1] or FW75-C200 Data Sheet [2]. Complete functionality of the module is only guaranteed within the specified minimum and maximum VCC voltage operating range. Ensure that the input voltage at the VCC pins never drops below the minimum limit of the operating range when the module is switched on. Operation above the operating range maximum limit is not recommended and extended exposure beyond it may affect device reliability. Stress beyond the VCC absolute maximum ratings can cause permanent damage to the module: if necessary, voltage spikes beyond VCC absolute maximum ratings must be restricted to values within the specified limits by using appropriate protection. When designing the power supply for the application, pay specific attention to power losses and transients. The DC power supply must be able to provide a voltage profile to the VCC pins with the following characteristics: Voltage drop during transmission must be lower than 250 mV FW75-C200. CDMA-2X-11004-3 Preliminary System description Page 11 of 43 LISA-C200 & FW75-C200 - System Integration Manual Any degradation in power supply performance (due to losses, noise or transients) will directly affect the RF performance of the module since the single external DC power source indirectly supplies all the digital and analog interfaces, and also directly supplies the RF power amplifier (PA). 1.4.2.1 VCC application circuits LISA-C200 & FW75-C200 modules must be supplied through the VCC pins by one (and only one) proper DC power supply that must be one of the following: Switching regulator Low Drop-Out (LDO) linear regulator Rechargeable Li-Ion battery Primary (disposable) battery Main Supply Available? No, portable device Battery Li-Ion 3.7 V Yes, always available Main Supply Voltage >5 V? No, less than 5 V Linear LDO Regulator Yes, greater than 5 V Switching Step-Down Regulator Figure 3: VCC supply concept selection The switching step-down regulator is the typical choice when the available primary supply source has a nominal voltage much higher (e.g. greater than 5 V) than the LISA-C200 & FW75-C200 modules operating supply voltage. The use of switching step-down provides the best power efficiency for the overall application and minimizes current drawn from the main supply source. The use of an LDO linear regulator becomes convenient for a primary supply with a relatively low voltage (e.g. less than 5 V). In this case the typical 90% efficiency of the switching regulator will diminish the benefit of voltage step-down and no true advantage will be gained in input current savings. On the opposite side, linear regulators are not recommended for high voltage step-down as they will dissipate a considerable amount of energy in thermal power. If LISA-C200 & FW75-C200 modules are deployed in a mobile unit where no permanent primary supply source is available, then a battery will be required to provide VCC. A standard 3-cell Lithium-Ion battery pack directly connected to VCC is the usual choice for battery-powered devices. During charging, batteries with Ni-MH chemistry typically reach a maximum voltage that is above the maximum rating for VCC, and should therefore be avoided. The use of primary (not rechargeable) battery is uncommon, since the most cells available are seldom capable of delivering the peak current due to high internal resistance. Keep in mind that the use of batteries requires the implementation of a suitable charger circuit (not included in LISA-C200 & FW75-C200 modules). The charger circuit should be designed in order to prevent over-voltage on VCC beyond the upper limit of the absolute maximum rating. The following sections highlight some design aspects for each of the supplies listed above. CDMA-2X-11004-3 Preliminary System description Page 12 of 43 LISA-C200 & FW75-C200 - System Integration Manual Switching regulator The characteristics of the switching regulator connected to VCC pins should meet the following requirements: Power capability: the switching regulator with its output circuit must be capable of providing a voltage value to the VCC pins within the specified operating range and must be capable of delivering greater than 1.2 Amps for safe design margin Low output ripple: the switching regulator together with its output circuit must be capable of providing a clean (low noise) VCC voltage profile High switching frequency: for best performance and for smaller applications select a switching frequency ≥ 600 kHz (since L-C output filter is typically smaller for high switching frequency). The use of a switching regulator with a variable switching frequency or with a switching frequency lower than 600 kHz must be carefully evaluated since this can produce noise in the VCC voltage profile. An additional L-C low-pass filter between the switching regulator output to VCC supply pins can mitigate the ripple on VCC, but adds extra voltage drop due to resistive losses on series inductors PWM mode operation: select preferably regulators with Pulse Width Modulation (PWM) mode. While in active mode Pulse Frequency Modulation (PFM) mode and PFM/PWM mode transitions must be avoided to reduce the noise on the VCC voltage profile. Switching regulators able to switch between low ripple PWM mode and high efficiency burst or PFM mode can be used, provided the mode transition from idle mode (current consumption approximately 2 mA) to active mode (current consumption approximately 100 mA): it is permissible to use a regulator that switches from the PWM mode to the burst or PFM mode at an appropriate current threshold (e.g. 60 mA) Output voltage slope: ( not necessary for CDMA solution, ok to delete-RJC) the use of the soft start function provided by some voltage regulator must be carefully evaluated, since the voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 1 ms to allow a proper switch-on of the module Figure 4 and the components listed in Table 4 show an example of a high reliability power supply circuit, where the module VCC is supplied by a step-down switching regulator capable of delivering 2.5 A current pulses with low output ripple and with fixed switching frequency in PWM mode operation greater than 1 MHz. The use of a switching regulator is suggested when the difference from the available supply rail to the VCC value is high: switching regulators provide good efficiency transforming a 12 V supply to the typical 3.8 V value of the VCC supply. 12V u-blox C200 VIN R1 RUN BD BOOST VC 10 RT C1 R2 C2 C3 C4 C5 7 PG R3 C6 SW D1 FB SYNC L1 U1 VCC L2 C7 R4 C8 C9 GND R5 11 GND Figure 4: Suggested schematic design for the VCC voltage supply application circuit using a step-down regulator CDMA-2X-11004-3 Preliminary System description Page 13 of 43 LISA-C200 & FW75-C200 - System Integration Manual Reference Description Part Number – Manufacturer C1 47 µF Capacitor Aluminum 0810 50 V MAL215371479E3 – Vishay C2 10 µF Capacitor Ceramic X7R 5750 15% 50 V C5750X7R1H106MB – TDK C3 10 nF Capacitor Ceramic X7R 0402 10% 16 V C4 680 pF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71C103KA01 – Murata GRM155R71H681KA01 – Murata C5 22 pF Capacitor Ceramic COG 0402 5% 25 V GRM1555C1H220JZ01 – Murata C6 10 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71C103KA01 – Murata C7 C8 470 nF Capacitor Ceramic X7R 0603 10% 25 V 22 µF Capacitor Ceramic X5R 1210 10% 25 V GRM188R71E474KA12 – Murata C37 330 µF Capacitor Tantalum D_SIZE 6.3 V 45 mΩ T520D337M006ATE045 - KEMET D1 Schottky Diode 40 V 3 A MBRA340T3G - ON Semiconductor L1 10 µH Inductor 744066100 30% 3.6 A 744066100 - Wurth Electronics L2 1 µH Inductor 7445601 20% 8.6 A 7445601 - Wurth Electronics R1 470 kΩ Resistor 0402 5% 0.1 W 2322-705-87474-L - Yageo R2 15 kΩ Resistor 0402 5% 0.1 W 2322-705-87153-L - Yageo R3 22 kΩ Resistor 0402 5% 0.1 W 2322-705-87223-L - Yageo R4 390 kΩ Resistor 0402 1% 0.063 W RC0402FR-07390KL - Yageo R5 100 kΩ Resistor 0402 5% 0.1 W 2322-705-70104-L - Yageo U1 Step Down Regulator MSOP10 3.5 A 2.4 MHz LT3972IMSE#PBF - Linear Technology GRM32ER61E226KE15 – Murata Table 4: Suggested components for the VCC voltage supply application circuit using a step-down regulator Low Drop-Out (LDO) linear regulator The characteristics of the LDO linear regulator connected to the VCC pins should meet the following requirements: Power capabilities: the LDO linear regulator with its output circuit must be capable of providing a proper voltage value to the VCC pins and of delivering 1.2 A Power dissipation: the power handling capability of the LDO linear regulator must be checked to limit its junction temperature to the maximum rated operating range (i.e. check the voltage drop from the max input voltage to the min output voltage to evaluate the power dissipation of the regulator) Figure 5 and the components listed in Table 5 show an example of a power supply circuit, where the VCC module supply is provided by an LDO linear regulator capable of delivering 1.2 Amps, with proper power handling capability. The use of a linear regulator is suggested when the difference from the available supply rail and the VCC value is low: linear regulators provide high efficiency when transforming a 5 V supply to the 3.6 V typical value of the VCC supply. u-blox C200 5V IN OUT VCC U1 C1 R1 R2 SHDN ADJ GND C2 R3 GND Figure 5: Suggested schematic design for the VCC voltage supply application circuit using an LDO linear regulator CDMA-2X-11004-3 Preliminary System description Page 14 of 43 LISA-C200 & FW75-C200 - System Integration Manual Reference Description Part Number - Manufacturer C1 10 µF Capacitor Ceramic X5R 0603 20% 6.3 V GRM188R60J106ME47 - Murata C2 10 µF Capacitor Ceramic X5R 0603 20% 6.3 V GRM188R60J106ME47 - Murata R1 47 kΩ Resistor 0402 5% 0.1 W RC0402JR-0747KL - Yageo Phycomp R2 4.7 kΩ Resistor 0402 5% 0.1 W RC0402JR-074K7L - Yageo Phycomp R3 2.2 kΩ Resistor 0402 5% 0.1 W RC0402JR-072K2L - Yageo Phycomp U1 LDO Linear Regulator ADJ 3.0 A LT1764AEQ#PBF - Linear Technology Table 5: Suggested components for VCC voltage supply application circuit using an LDO linear regulator Rechargeable Li-Ion battery Rechargeable Li-Ion batteries connected to the VCC pins should meet the following requirements: Maximum pulse and DC discharge current: the rechargeable Li-Ion battery with its output circuit must be capable of delivering 1.2 A to the VCC pins and must be capable of delivering a DC current greater than the module maximum average current consumption to VCC pins. The maximum pulse discharge current and the maximum DC discharge current are not always reported in battery data sheets, but the maximum DC discharge current is typically almost equal to the battery capacity in Amp-hours divided by 1 hour DC series resistance: the rechargeable Li-Ion battery with its output circuit must be capable of avoiding a VCC voltage drop greater than 250 mV during peak currents (Max Tx Power). Primary (disposable) battery The characteristics of a primary (non-rechargeable) battery connected to VCC pins should meet the following requirements: Maximum pulse and DC discharge current: the non-rechargeable battery with its output circuit must be capable of delivering 1.2 A to the VCC pins and must be capable of delivering a DC current greater than the module maximum average current consumption at the VCC pins. The maximum pulse and the maximum DC discharge current is not always reported in battery data sheets, but the maximum DC discharge current is typically almost equal to the battery capacity in Amp-hours divided by 1 hour DC series resistance: the non-rechargeable battery with its output circuit must be capable of avoiding a VCC voltage drop greater than 250 mV during peak currents (Max Tx Power). Additional recommendations for the VCC supply application circuits To reduce voltage drops, use a low impedance power source. The resistance of the power supply lines (connected to the VCC and GND pins of the module) on the application board and battery pack should also be considered and minimized: cabling and routing must be as short as possible in order to minimize power losses. Three3 or five4 pins are allocated for VCC supply. Another seven pins are designated for GND connection. Even if all the VCC pins and all the GND pins are internally connected within the module, it is recommended to properly connect all of them to supply the module in order to minimize series resistance losses. The placement ceramic capacitors on the VCC line on the main board close to the connector will benefit operation. To reduce voltage ripple and noise, place the following near the VCC pins: 100 nF capacitor (e.g Murata GRM155R61A104K) to filter digital logic noise from clocks and data sources 22 µF capacitor (e.g. Murata GRM31CR60J226K) to supply local DC energy. Figure 6 shows the complete configuration but the mounting of each single component depends on the application design. LISA-C200. FW75. CDMA-2X-11004-3 Preliminary System description Page 15 of 43 LISA-C200 & FW75-C200 - System Integration Manual u-blox C200 3.6V VCC VCC VCC VCC VCC C1 C2 LISA-C200 FW75 GND Figure 6: Suggested schematic design to reduce voltage ripple and noise and to avoid undershoot/ overshoot on voltage drops Reference Description Part Number - Manufacturer C1 22 µF Capacitor Ceramic 6.3 V 45 GRM31CR60J226K - Murata C2 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata Table 6: Suggested components to reduce voltage ripple and noise and to avoid undershoot/ overshoot on voltage drops CDMA-2X-11004-3 Preliminary System description Page 16 of 43 LISA-C200 & FW75-C200 - System Integration Manual 1.4.3 Current consumption profiles During operation, the current drawn by the LISA-C200 & FW75-C200 modules through the VCC pins can vary by several orders of magnitude. This ranges from continuous high current drawn in CDMA connected mode, to the low current consumption during in idle mode. 1.4.3.1 CDMA connected mode During a CDMA connection, the module can transmit and receive continuously due to the Frequency Division Duplex (FDD) mode of operation with the Code Division Multiple Access (CDMA). The current consumption depends again on output RF power, which is always regulated by network commands. These power control commands are logically divided into a slot of 1.25 ms, thus the rate of power change can reach a maximum rate of 800 Hz. Since transmission and reception are continuously enabled due to FDD CDMA implemented in the 3G that differs from the TDMA implemented in the 2G case. In the worst scenario, corresponding to a continuous transmission and reception at maximum output power (approximately 250 mW or 24 dBm), the current dra wn by the module at the VCC pins is in the order of continuous 600-700 mA. Even at lowest output RF power (approximately 0.01 µW or -50 dBm), the current is in the order of less than 100 mA due to module baseband processing and transceiver activity. An example of current consumption profile of the data module in CDMA continuous transmission mode is shown in Figure 7. Curre nt [mA] 610 mA 700 600 500 Depends on TX pow er 400 Not actual data f or illustration 300 <100 mA 200 100 1 slot 3G frame Time [ms] Figure 7: VCC current consumption profile versus time during a CDMA connection, with VCC=3.8 V When a packet data connection is established, the actual current profile depends on the amount of transmitted packets; there might be some periods of inactivity between allocated slots where current consumption drops about 100 mA. Alternatively, at higher data rates the transmitted power is likely to increase due to the higher quality signal required by the network to cope with enhanced data speed. CDMA-2X-11004-3 Preliminary System description Page 17 of 43 LISA-C200 & FW75-C200 - System Integration Manual 1.5 System functions 1.5.1 Module power on The module power on sequence is initiated in one of these ways: Rising edge on the VCC pin to a valid voltage for module supply AND if the PWR_ON pin is permanently low when VCC is applied Falling edge on the PWR_ON pin (pin must be held low for >150 msec) Name Description Remarks PWR_ON Power on input PWR_ON pin has internal pull up resistor. Recommended to use open collector or drain configuration to pull down. Table 7: Power on pin The PWR_ON pin ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the line is externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin. 1.5.1.1 Rising edge on VCC \When a supply is connected to VCC pins, the module supply supervision circuit controls the subsequent activation of the power up state machines: the module is switched on when the voltage rises up to the VCC operating range minimum limit (3.4 V) starting from a voltage value lower than 2.25 V (See LISA-C200 Data Sheet [1] or the FW75-C200 Data Sheet [2]), provided that the PWR_ON pin is permanently low when VCC is applied. 1.5.1.2 Falling edge on PWR_ON The module power on sequence starts when a falling edge is forced on the PWR_ON input pin. After applying a falling edge, it is suggested to hold a low level on the PWR_ON signal for at least 300 ms to properly switch on the module. The electrical characteristics of the PWR_ON input pin are different from the other digital I/O interfaces: the high and the low logic levels have different operating ranges and the pin is not-tolerant to voltages up to the battery voltage. The detailed electrical characteristics are described in the LISA-C200 Data Sheet [1] or the FW75-C200 Data Sheet [2]. Once the module has been turned on, PWR_ON pin has no effect. On the other hand it makes no sense to keep this pin low once the module has been turned on: if the pin is kept low it will draw unnecessary current. Following are some typical examples of application circuits to turn the module on using the PWR_ON input pin. The simplest way to turn on the module is to use a push button that shorts the PWR_ON pin to ground. If the PWR_ON input is connected to an external device (e.g. application processor), it is suggested to use an open drain output on the external device. CDMA-2X-11004-3 Preliminary System description Page 18 of 43 LISA-C200 & FW75-C200 - System Integration Manual u-blox C200 Power-on push button PWR_ON ESD Application Processor u-blox C200 Open Drain Output PWR_ON Figure 8: PWR_ON application circuits using a push button and an open drain output of an application processor Reference Description Remarks ESD CT0402S14AHSG - EPCOS Varistor array for ESD protection Table 8: Example of pull-up resistor and ESD protection for the PWR_ON application circuits 1.5.1.3 Additional considerations The module is switched on when the voltage rises up to the VCC operating range: the first time that the module is used, it is switched on in this way. Then, the proper way to switch off the module is by means of the AT+CPWROFF command. When the module is in power-off mode, i.e. the AT+CPWROFF command has been sent and a voltage value within the operating range limits is still provided to the VCC pin, the digital inputoutput pads of the baseband chipset (i.e. all the digital pins of the module) are locked in tri-state (i.e. floating). The power down tri-state function isolates the module pins from its environment, when no proper operation of the outputs can be guaranteed. The module can be switched on from power-off mode by forcing a proper start-up event (i.e. a falling edge on the PWR_ON pin). After the detection of a start-up event, all the digital pins of the module are held in tri-state until all the internal LDO voltage regulators are turned on in a defined power-on sequence. Then, as described in Datasheet the baseband core is still held in reset state for a time interval: the internal reset signal (which is not available on a module pin) is still low and any signal from the module digital interfaces is held in reset state. The reset state of all the digital pins is reported in the pin description table of the LISA-C200 Data Sheet [1] or the FW75-C200 Data Sheet [2]. When the internal signal is released, the configuration of the module interfaces starts: during this phase any digital pin is set in a proper sequence from the reset state to the default operational configuration. Finally, the module is fully ready to operate when all interfaces are configured. The Internal Reset signal is not available on a module pin. CDMA-2X-11004-3 Preliminary System description Page 19 of 43 LISA-C200 & FW75-C200 - System Integration Manual 1.5.2 Module power off The correct way to switch off LISA-C200 & FW75-C200 modules is by means of +CPWROFF AT command (more details in u-blox C200 AT Commands Manual [3]): in this way the current parameter settings are saved in the module’s non-volatile memory and a proper network detach is performed. An under-voltage shutdown will be done if the VCC supply is removed, but in this case the current parameter settings are not saved in the module’s non-volatile memory and a proper network detach cannot be performed. 1.5.3 Module reset The module reset can be performed: Forcing a low level on the RESET_N input pin, causing an “external” or “hardware” reset (LISA-C200 only) AT+CFUN command (more details in u-blox C200 AT Commands Manual [3]): in this case an “internal” or “software” reset is performed, causing an asynchronous reset of the baseband processor 1.6 RF connection The ANT connector has 50 nominal characteristic impedance and must be connected to the antenna through a 50 transmission line to allow transmission and reception of radio frequency (RF) signals in the Cell and PCS operating bands. Name Description Remarks ANT FW75 LISA-C200 RF connector Zo = 50 nominal characteristic impedance. U.FL connector Surface Mount pad Table 9: Antenna connector The ANT port ESD immunity rating is 500 V (according to IEC 61000-4-2). Higher protection level could be required if the line is externally accessible on the application board. Choose an antenna with optimal radiating characteristics for the best electrical performance and overall module functionality. Focus on minimizing the insertion loss between radiating antenna and the module RF connector. Overall system performance depends on antenna reception and transmission. See section 2.4 for further details regarding antenna guidelines. CDMA-2X-11004-3 Preliminary System description Page 20 of 43 LISA-C200 & FW75-C200 - System Integration Manual 1.7 Serial communication LISA-C200 & FW75-C200 modules provide the following serial communication interfaces where AT command interface and Packet-Switched Data communication are concurrently available: One asynchronous serial interface (UART) that provides RS-232 functionality conforming to ITU-T V.24 Recommendation [4], with limited data rate. One full-speed USB 2.0 compliant interface, with maximum data rate of 12 Mb/s. Only one interface is active. Default is USB, if no USB is detected then it is assumed that the UART interface is desired. LISA-C200 & FW75-C200 modules are designed to operate as a CDMA wireless modem, which represents the data circuit-terminating equipment (DCE) as described by the ITU-T V.24 Recommendation [4]. A customer application processor connected to the module through one of the interfaces represents the data terminal equipment (DTE). All the interfaces listed above are controlled and operated with: Sprint required AT Commands Verizon required AT Commands AT commands according to 3GPP TS 27.010 [7] AT commands according to 3GPP TS 27.005 [6] AT commands according to 3GPP TS 27.010 u-blox AT commands For the complete list of supported AT commands and their syntax refer to the u-blox C200 AT Commands Manual [3]. The USB interface, using all the lines provided (VUSB_DET, USB_D+ and USB_D-), can be used for firmware upgrade: To directly enable PC (or similar) connection to the module for firmware upgrade, provide direct access on the application board to the VUSB_DET, USB_D+ and USB_D- lines of the module . Also provide access to the PWR_ON & HW_SHUTDOWN pins, or enable the DC supply connected to the VCC pin to start the module firmware upgrade The following sub-chapters describe serial interface configuration and provide a detailed description of each interface for the application circuits. 1.7.1 Serial interfaces configuration UART and USB serial interfaces are available as AT command interface and for Packet-Switched Data communication. The serial interfaces are configured as described in Table 10 (for information about further settings, please refer to the u-blox C200 AT Commands Manual [3]). Note : The UART is 5 wire implementation therefore DTR, DSR and DCD functions are not available. CDMA-2X-11004-3 Preliminary System description Page 21 of 43 LISA-C200 & FW75-C200 - System Integration Manual Interface AT Settings Comments UART interface Enabled Multiplexing mode can be enabled by AT+CMUX command providing following channels: Channel 0: control channel Channel 1: AT commands Channel 2: data connection AT+IPR=115200 Baud rate: 115200 b/s AT+ICF=0,0 Frame format: 8 bits, no parity, 1 stop bit USB interface Enabled Table 10: Default serial interfaces configuration 1.7.2 Asynchronous serial interface (UART) The UART interface is a 5-wire unbalanced asynchronous serial interface that provides AT commands interface and PSD data communication. UART interface provides RS-232 functionality conforming to the ITU-T V.24 Recommendation (more details available in ITU Recommendation [4]), with CMOS compatible signal levels: 0 V for low data bit or ON state, and 2.8 V for high data bit or OFF state. One external voltage translators (e.g. Maxim MAX13234E) could be used to provide RS-232 (5 lines) compatible signal levels. This chip translates the voltage levels from 1.8 V (module side) to the RS-232 standard. For detailed electrical characteristics refer to LISA-C200 Data Sheet [1] or the FW75C200 Data Sheet [2]. FW75-C200 logic levels are 2.8 V interface. LISA-C200 logic levels are 1.8 V interface. The LISA-C200 & FW75-C200 modules are designed to operate as a CDMA wireless modem, which represents the data circuit-terminating equipment (DCE) as described by the ITU-T V.24 Recommendation [4]. A customer application processor connected to the module through the UART interface represents the data terminal equipment (DTE). The signal names of the LISA-C200 & FW75-C200 modules UART interface conform to the ITU-T V.24 Recommendation [4]. UART interfaces include the following lines: Name Description Remarks RI Ring Indicator Module output RTS Ready to send Module hardware flow control input Circuit 105 (Request to send) in ITU-T V.24 FW75 - Internal active pull-up to V_INT (2.8 V) interface. LISA-C200- Internal active pull-up to V_INT (1.8 V) interface. CTS Clear to send Module hardware flow control output Circuit 106 (Ready for sending) in ITU-T V.24 FW75-C200 - Internal active pull-up to V_INT (2.8 V) interface. LISA-C200- Internal active pull-up to V_INT (1.8 V) interface. TxD Transmitted data Module data input Circuit 103 (Transmitted data) in ITU-T V.24 Internal active pull-up to V_INT (2.8 V) enabled. FW75-C200- Internal active pull-up to V_INT (2.8 V) interface. LISA-C200- Internal active pull-up to V_INT (1.8 V) interface. RxD Received data Module data output Circuit 104 (Received data) in ITU-T V.24 FW75-C200- Internal active pull-up to V_INT (2.8 V) interface. LISA-C200- Internal active pull-up to V_INT (1.8 V) interface. GND Ground Table 11: UART interface signals CDMA-2X-11004-3 Preliminary System description Page 22 of 43 LISA-C200 & FW75-C200 - System Integration Manual The UART interface pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the lines connected to these pins. UART application circuits Providing the TxD, RxD, RI, RTS and CTS lines only (not using the complete V.24 link) Modem DSR, DCD and DTR lines is not available in the application, the application circuit described in Figure 9 must be implemented: u-blox C200 (DCE) Application Processor (DTE) TxD RxD RTS CTS 0Ω TP 0Ω TP 0Ω TP 0Ω TP TXD RXD RTS CTS DTR DSR RI RI DCD GND GND Figure 9: UART interface application circuit with partial V.24 link (5-wire) in the DTE/DCE serial communication Additional considerations If the module USB interface is connected to the application processor, testpoints can be added on the lines to accommodate the access and a 0 Ω series resistor must be mounted on each line to detach the module pin from any other connected device. Otherwise, if the USB interface is not connected to the application processor, it is highly recommended to provide direct access to VUSB_DET, USB_D+, USB_D- lines for execution of firmware upgrade over USB and for debug purpose. In both cases, provide as well access to RESET_N pin, or to the PWR_ON pin, or enable the DC supply connected to the VCC pin to start the module firmware upgrade. CDMA-2X-11004-3 Preliminary System description Page 23 of 43 LISA-C200 & FW75-C200 - System Integration Manual 1.7.3 USB interface LISA-C200 & FW75-C200 modules provide a full-speed USB interface at 12 Mb/s compliant with the Universal Serial Bus Revision 2.0 specification [9]. It acts as a USB device and can be connected to any USB host such as a PC or other Application Processor. The USB-device shall look for all upper-SW-layers like any other serial device. This means that LISA-C200 & FW75-C200 modules emulate all serial control logical lines. If the logical DTR line isn't enabled by the USB host, the module doesn’t answer to AT commands by the USB interface. Name Description Remarks VUSB_DET USB detect input Apply 5 V typical to enable USB USB_D+ USB Data Line D+ 90 Ω nominal differential impedance. Pull-up or pull-down resistors and external series resistors as required by the USB 2.0 high-speed specification [9] are part of the USB pad driver and need not be provided externally. USB_D- USB Data Line D- 90 Ω nominal differential impedance. Pull-up or pull-down resistors and external series resistors as required by the USB 2.0 high-speed specification [9] are part of the USB pad driver and need not be provided externally. Table 12: USB pins The USB interface pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting a very low capacitance (i.e. less or equal to 1 pF) ESD protection (e.g. Tyco Electronics PESD0402-140 ESD protection device) on the lines connected to these pins. LISA-C200 & FW75-C200 module identifies itself by its VID (Vendor ID) and PID (Product ID) combination, included in the USB device descriptor. VID and PID of LISA-C200 & FW75-C200 modules are the following: VID = 0x1546 PID = 0x1121 1.7.3.1 USB application circuit Since the module acts as a USB device, the USB supply (5.0 V typ.) must be provided to VUSB_DET by the connected USB host. The USB interface is enabled only when a valid voltage as USB supply is detected by the VUSB_DET input. Neither the USB interface, nor the whole module is supplied by the VUSB_DET input: the VUSB_DET senses the USB supply voltage and absorbs few microamperes. The USB_D+ and USB_D- lines carry the USB serial data and signaling. The lines are used in single ended mode for relatively low speed signaling handshake, as well as in differential mode for fast signaling and data transfer. USB pull-up or pull-down resistors on pins USB_D+ and USB_D- as required by the Universal Serial Bus Revision 2.0 specification [9] are part of the USB pad driver and do not need to be externally provided. External series resistors on pins USB_D+ and USB_D- as required by the Universal Serial Bus Revision 2.0 specification [9] are also integrated: characteristic impedance of USB_D+ and USB_D- lines is specified by the USB standard. The most important parameter is the differential characteristic impedance applicable for odd-mode electromagnetic field, which should be as close as possible to 90 differential: signal integrity may be degraded if the PCB layout is not optimal, especially when the USB signaling lines are very long. CDMA-2X-11004-3 Preliminary System description Page 24 of 43 LISA-C200 & FW75-C200 - System Integration Manual USB DEVICE CONNECTOR u‐blox C200 VBUS VUSB_DET D+ USB_D+ D- USB_D- D1 D2 D3 C1 GND GND Figure 10: USB Interface application circuit Reference Description Part Number - Manufacturer D1, D2, D3 Very Low Capacitance ESD Protection PESD0402-140 - Tyco Electronics C2 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata Table 13: Component for USB application circuit If the USB interface is not connected to the application processor, it is highly recommended to provide direct access to the VUSB_DET, USB_D+, USB_D- lines for execution of firmware upgrade over USB and for debug purpose: testpoints can be added on the lines to accommodate the access. Provide access to RESET_N pin, or to the PWR_ON pin, or enable the DC supply connected to the VCC pin to start the module firmware upgrade If the USB interface is not used, the USB_D+, USB_D- and VUSB_DET pins can be left unconnected, but it is highly recommended to provide direct access to the lines for execution of firmware upgrade and for debug purpose. 1.7.4 MUX Protocol (3GPP 27.010) LISA-C200 & FW75-C200 modules have a software layer with MUX functionality, 3GPP TS 27.010 Multiplexer Protocol [7], available on the UART physical link. The USB interface doesn’t support the multiplexer protocol. This is a data link protocol (layer 2 of OSI model) which uses HDLC-like framing and operates between the module (DCE) and the application processor (DTE) and allows a number of simultaneous sessions over the UART: the user can concurrently use AT command interface on one MUX channel and Packet-Switched Data communication on another MUX channel.. Each session consists of a stream of bytes transferring various kinds of data such as SMS, PSD, AT commands in general. This permits, for example, SMS to be transferred to the DTE when a data connection is in progress. The following virtual channels are defined: Channel 0: control channel Channel 1: AT commands Channel 2: data connection 1.8 Reserved pins (RSVD) LISA-C200 & FW75-C200 modules have pins reserved for future use. All the RSVD pins/pads must be left unconnected on the application board. CDMA-2X-11004-3 Preliminary System description Page 25 of 43 LISA-C200 & FW75-C200 - System Integration Manual 1.9 Schematic for LISA-C200 and FW75-C200 modules integration Figure 11 shows the integration of a LISA-C200 / FW75-C200 modules into an application board, using all the module interfaces. FW75-C200 3V6 Antenna Connection FW75 – U.FL Connector LISA-C200 SMT PAD ANT VCC VCC SIM Card Holder VCC VCC 22µF 100nF VCC 1k V_INT SW1 GPIO5 SW2 CCVCC (C1) VSIM CCVPP (C6) GND CCIO (C7) SIM_IO Application Processor SIM_CLK CCCLK (C3) SIM_RST CCRST (C2) GND (C5) PWR_ON Open Drain Output 470k 47pF 47pF 47pF 47pF 100nF ESD ESD ESD ESD ESD ESD Ferrite Bead Open Drain Output HW_SHUTDOWN (FW75-C200) RESET_N (LISA-C200) 47pF DTE FW75 2.8V LISA – 1.8V GPIO2 TXD RXD RTS CTS 0Ω TP 0Ω TP 0Ω TP 0Ω TP GPIO3 TXD GPIO4 RXD RTS CTS LISA‐C200 only DTR DTR DSR DSR RI RI GND GND USB 2.0 Host VBUS VUSB_DET D+ USB_D+ D- USB_D100nF GND GND 3V8 Network Indicator GPIO1 Figure 11: Example schematic integrating FW75-C200/LISA-C200 module in an application board, using all the interfaces UART FW75-C200 and LISA-C200 pins use different voltage levels (1.8V LISA-C200, 2.8V FW75-C200) CDMA-2X-11004-3 Preliminary System description Page 26 of 43 LISA-C200 & FW75-C200 - System Integration Manual 1.10 Approvals LISA-C200 & FW75-C200 modules have been or will be approved under the following schemes: CDG1 CDMA Development Group 1 Radio Conformance Testing CDG2 CDMA Development Group 2 Inter-operability Sprint Carrier Certification Verizon Carrier Certification FCC (Federal Communications Commission) IC (Industry Canada) 1.10.1 Declaration of Conformity for products marked with the FCC logo - United States only Radiofrequency radiation exposure Information: this equipment complies with FCC radiation exposure limits prescribed for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. 1.10.2 Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by u-blox could void the user's authority to operate the equipment. Manufacturers of mobile or fixed devices incorporating the LISA-C200 & FW75-C200 modules are authorized to use the FCC Grants and Industry Canada Certificates of the LISA-C200 & FW75C200 modules for their own final products according to the conditions referenced in the certificates. The FCC Label shall in the above case be visible from the outside, or the host device shall bear a second label stating: for FW75: “Contains FCC ID: XU9-FW75” And for LISA C200 “Contains FCC ID: R5Q-LISAC200A” The IC Label shall in the above case be visible from the outside, or the host device shall bear a second label stating for FW75: “Contains IC: 8694A-FW75” And for LISA C200 “Contains IC: 8595B-LISAC200A” Canada, Industry Canada (IC) Notices Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Canada, avis d'Industrie Canada (IC) Les changements ou modifications n'ont pas était expressément approuvés par la partie responsable de la conformité, ils pourraient annulée l'autorité de l'utilisateur pour exploiter l'équipement. CDMA-2X-11004-3 Preliminary System description Page 27 of 43 LISA-C200 & FW75-C200 - System Integration Manual 2 Design-In 2.1 Design-in checklist 2.1.1 Schematic checklist The following are the most important points for a simple schematic check: DC supply must provide a nominal voltage at VCC pin above the minimum operating range limit. VCC supply should be clean, with very low ripple/noise: suggested passive filtering parts can be inserted. Provide appropriate access to USB interface and/or to UART RxD, TxD, CTS, RTS lines for debugging. Insert the suggested passive filtering parts on each used analog audio line. Check 50 nominal characteristic impedance of the RF transmission line connected to ANT coax connector or Printed Circuit Board 50 transmission line impedance for LISA-C200 Follow the recommendations of the antenna producer for correct antenna installation and deployment. DC supply must be capable of supporting 1.2 A, providing a voltage at VCC pin above the minimum operating range limit and with a maximum 250 mV voltage drop from the nominal value. Connect only one DC supply to VCC: different DC supply systems are mutually exclusive. Don’t apply loads which might exceed the limit for maximum available current from V_INT supply. Check that voltage level of any connected pin does not exceed the relative operating range. Capacitance and series resistance must be limited on each SIM signal to match the SIM specifications. Insert the suggested low capacitance ESD protection and passive filtering parts on each SIM signal. Check UART signals direction, since the signal names follow the ITU-T V.24 Recommendation [4]. Provide appropriate access to USB interface and/or to UART RxD, TxD lines and access to PWR_ON and/or HW_SHUTDOWN lines on the application board in order to flash/upgrade the module firmware. Add a proper pull-up resistor to a proper supply on each DDC (I2C) interface line, if the interface is used. Capacitance and series resistance must be limited on each line of the DDC interface. Use transistors with at least an integrated resistor in the base pin or otherwise put a 10 kΩ resistor on the board in series to the GPIO when those are used to drive LEDs. Provide proper precautions for ESD immunity as required on the application board. All unused pins can be left floating on the application board Layout checklist The following are the most important points for a simple layout check: Ensure no coupling occurs with other noisy or sensitive signals (primarily SIM signals). VCC line should be wide and short. Ensure proper grounding. Consider “No-routing” areas for the Data Module footprint. Optimize placement for minimum length of RF line and closer path from DC source for VCC. Design USB_D+ / USB_D- connection as 90 differential pair. 2.1.2 Antenna checklist Antenna should have 50 impedance, V.S.W.R less then 3:1, recommended 2:1 on operating bands in deployment geographical area. Follow the recommendations of the antenna producer for correct antenna installation and deployment (PCB layout and matching circuitry). CDMA-2X-11004-3 Preliminary Design-In Page 28 of 43 LISA-C200 & FW75-C200 - System Integration Manual 2.2 Connectors (FW75) The following design information is to aid the design for proper selection of mating connectors and antennas. 2.2.1 FW75-C200 modem connector Manufacturer Molex Series Name SlimStack Part No. 52991-0808 Specification PS-54-167-002 Description Receptacle 80 pins, 0.50mm pitch, 4mm stacking height Remarks Website : www.molex.com Drawing: 529910708_sd.pdf (mechanical, land pattern and reel specifications) Data sheet : 05339160208_PCB_RECEPTABLES.pdf Table 14: FW75-C200 modem connector Figure 12: FW75-C200 modem connector 2.2.2 FW75-C200 Board to Board host connector Manufacturer Molex Series Name SlimStack Part No. 53916-0808 Specification PS-54-167-002 Description Header 80 pins, 0.50mm pitch, 4mm stacking height Remarks Website : www.molex.com Drawing: 539160208_sd.pdf (mechanical, land pattern and reel specifications) Data sheet : 05339160208_PCB_HEADERS.pdf Table 15: FW75-C200 host mate connector Figure 13: FW75-C200 host mate connector CDMA-2X-11004-3 Preliminary Design-In Page 29 of 43 LISA-C200 & FW75-C200 - System Integration Manual 2.2.3 FW75-C200 RF antenna connector Manufacturer Molex Series Name 73412 Part No. 73412-0110 Specification PS-73598-02 Description Microcoaxial RF, 50 Ω, PCB Vertical Jack Receptacle, SMT, 1.25 mm (0.049”) Mounted Height Remarks Website : www.molex.com Drawing: 734120110_sd.pdf (mechanical, land pattern and reel specifications) Data sheet: 0734120110_RF_COAX_CONNECTORS.pdf Table 16: FW75-C200 antenna connector Figure 14: FW75-C200 antenna connector CDMA-2X-11004-3 Preliminary Design-In Page 30 of 43 LISA-C200 & FW75-C200 - System Integration Manual 2.3 Design Guidelines The following design guidelines must be met for optimal integration of LISA-C200 module on the final application board. 2.3.1 Layout guidelines per pin function This section groups the u-blox C200 module pins by signal function and provides a ranking of importance in layout design. See 1: FW75-C200 : LISA-C200 Table 17 for a list of pins ranked by their importance in layout design. See the LISA-C200 Data Sheet [1] or the FW75 Data Sheet [2] for the complete pin lists. Rank Function st RF Connector nd Main DC Supply rd USB Signals th Ground th Sensitive Pin : Power On HW_SHUTDOWN th Pin(s) ANT VCC USB_D+ USB_DGND Remarks Very Important Design for 50 Very Important VCC line should be wide and short. Route away from sensitive analog signals. characteristic impedance. Very Important Route USB_D+ and USB_D- as differential lines: design for 90 differential impedance. Careful Layout Provide proper grounding. Careful Layout Avoid coupling with noisy signals. Common Practice Follow common practice rules for digital pin routing. PWR_ON HW_SHUTDOWN Digital pins and supplies: SIM Card Interface VSIM, SIM_CLK, SIM_IO, SIM_RST UART External Reset TXD, RXD, CTS, RTS, RI HW_SHUTDOWN RESET_N General Purpose I/O Layout USB detection GPIO1, GPIO2, GPIO3, GPIO4, GPIO5 VUSB_DET Supply for Interfaces V_INT : FW75-C200 : LISA-C200 Table 17: Pin list in order of decreasing importance for layout design CDMA-2X-11004-3 Preliminary Design-In Page 31 of 43 LISA-C200 & FW75-C200 - System Integration Manual 2.4 Antenna guidelines Antenna characteristics are essential for good functionality of the module. Antenna radiating performance has direct impact on the reliability of connections over the Air Interface. A bad termination of ANT can result in poor performance of the module. The following parameters should be checked: Item Recommendations Impedance 50 Ω nominal characteristic impedance Frequency Range Depends on the Mobile Network used. LISA-C200: - Cell Band B0: 824..894 MHz - PCS Band B1 B2: 1850..1990 MHz Input Power V.S.W.R >2 W peak <2:1 recommended, <3:1 acceptable Return Loss S11<-10 dB recommended, S11<-6 dB acceptable Gain <3 dBi Table 18: General recommendation for CDMA antenna To preserve the original u-blox FCC ID, antenna gain shall remain below 3 dBi. CDMA antennas are typically available as: Linear monopole: typical for fixed applications. The antenna extends mostly as a linear element with a dimension comparable to lambda/4 of the lowest frequency of the operating band. Magnetic base may be available. Cable or direct RF connectors are common options. The integration normally requires the fulfillment of some minimum guidelines suggested by antenna manufacturer Patch-like antenna: better suited for integration in compact designs (e.g. mobile phone). These are mostly custom designs where the exact definition of the PCB and product mechanical design is fundamental for tuning of antenna characteristics For integration observe these recommendations: Ensure 50 Ω antenna termination by minimizing the V.S.W.R. or return loss, as this will optimize the electrical performance of the module. See section 2.4.1 Select antenna with best radiating performance. See section 2.4.2 If a cable is used to connect the antenna radiating element to application board, select a short cable with minimum insertion loss. The higher the additional insertion loss due to low quality or long cable, the lower the connectivity Follow the recommendations of the antenna manufacturer for correct installation and deployment Do not include antenna within closed metal case Do not place antenna in close vicinity to end user since the emitted radiation in human tissue is limited by S.A.R. regulatory requirements Do not use directivity antenna since the electromagnetic field radiation intensity is limited in some countries Take care of interaction between co-located RF systems since the RF transmitted power may interact or disturb the performance of companion systems Place antenna far from sensitive analog systems or employ countermeasures to reduce electromagnetic compatibility issues that may arise CDMA-2X-11004-3 Preliminary Design-In Page 32 of 43 LISA-C200 & FW75-C200 - System Integration Manual 2.4.1 Antenna termination The LISA-C200 & FW75-C200 modules are designed to work on a 50 load. However, real antennas have no perfect 50 load on all the supported frequency bands. Therefore, to reduce as much as possible performance degradation due to antenna mismatch, the following requirements should be met: Measure the antenna termination with a network analyzer: connect the antenna through a coaxial cable to the measurement device, the |S11| indicates which portion of the power is delivered to antenna and which portion is reflected by the antenna back to the module output. A good antenna should have an |S11| below -10 dB over the entire frequency band. Due to miniaturization, mechanical constraints and other design issues, this value will not be achieved. An |S 11| value of about -6 dB – (in the worst case) - is acceptable. Figure 15 shows an example of this measurement: Figure 15: |S11| sample measurement of a penta-band antenna that covers in a small form factor the 4 bands (850 MHz, 900 MHz, 1800 MHz and 1900 MHz) Figure 16 shows comparable measurements performed on a wideband antenna. The termination is better, but the size of the antenna is considerably larger. Figure 16: |S11| sample measurement of a wideband antenna CDMA-2X-11004-3 Preliminary Design-In Page 33 of 43 LISA-C200 & FW75-C200 - System Integration Manual 2.4.2 Antenna radiation An indication of the antenna’s radiated power can be approximated by measuring the |S 21| from a target antenna to the measurement antenna, using a network analyzer with a wideband antenna. Measurements should be done at a fixed distance and orientation, and results compared to measurements performed on a known good antenna. Figure 17 through Figure 18 show measurement results. A wideband log periodic-like antenna was used, and the comparison was done with a half lambda dipole tuned at 900 MHz frequency. The measurements show both the |S11| and |S21| for the penta-band internal antenna and for the wideband antenna. Figure 17: |S11| and |S21| comparison between a 900 MHz tuned half wavelength dipole (green/purple) and a penta-band internal antenna (yellow/cyan) The half lambda dipole tuned at 900 MHz is known and has good radiation performance (both for gain and directivity). Then, by comparing the |S 21| measurement with antenna under investigation for the frequency where the half dipole is tuned (e.g. marker 3 in Figure 17) it is possible to make a judgment on the antenna under test: if the performance is similar then the target antenna is good. Figure 18: |S11| and |S21| comparison between a 900 MHz tuned half wavelength dipole (green/purple) and a wideband commercial antenna (yellow/cyan) Instead if |S21| values for the tuned dipole are much better than the antenna under evaluation (like for marker 1/2 area of Figure 18, where dipole is 5 dB better), then it can be argued that the radiation of the target antenna (the wideband dipole in this case) is considerably less. The same procedure should be repeated on other bands with half wavelength dipole re-tuned to the band under investigation. CDMA-2X-11004-3 Preliminary Design-In Page 34 of 43 LISA-C200 & FW75-C200 - System Integration Manual For good antenna radiation performance, antenna dimensions should be comparable to a quarter of the wavelength. Different antenna types can be used for the module, many of them (e.g. patch antennas, monopole) are based on a resonating element that works in combination with a ground plane. The ground plane, ideally infinite, can be reduced down to a minimum size that must be similar to one quarter of the wavelength of the minimum frequency that has to be radiated (transmitted/received). Numerical sample: frequency = 1 GHz wavelength = 30 cm minimum ground plane (or antenna size) = 7.5 cm. Below this size, the antenna efficiency is reduced. 2.5 ESD immunity test precautions The immunity of the device (i.e. the application board where LISA-C200 & FW75-C200 module is mounted) Electrostatic Discharge must be certified in compliance to the testing requirements standard [12], and the requirements for radio and digital cellular radio telecommunications system equipment standards [12] and [14]. The ESD test is performed at the enclosure port referred to as the physical boundary through which the EM field radiates. If the device implements an integral antenna, the enclosure port is seen as all insulating and conductive surfaces housing the device. If the device implements a removable antenna, the antenna port can be separated from the enclosure port. The antenna port comprises the antenna element and its interconnecting cable surfaces. The applicability of the ESD test depends on the device classification, as well the test on other ports or on interconnecting cables to auxiliary equipments depends to the device accessible interfaces and manufacturer requirements. Contact discharges are performed at conductive surfaces whereas air discharges are performed on insulating surfaces. Indirect contact discharges are performed on the measurement setup horizontal and vertical coupling planes. Implement the following precautions to satisfy ESD immunity test requirements performed at the device enclosure in compliance to the category level and shown in the following table. Application Category Immunity Level All exposed surfaces of the radio equipment and ancillary equipment in a representative configuration Contact Discharge 4 kV Air Discharge 8 kV Table 19: Electromagnetic Compatibility (EMC) ESD immunity requirement, standards “EN 61000-4-2, EN 301 489-1 V1.8.1, EN 301 489-7 V1.3.1” Although EMC certification (including ESD immunity testing) must be performed in the final application of the radio equipment EUT, results are provided for LISA modules performing the test with a representative configuration to show that requirements can be met. Since an external antenna is used, the antenna port can be separated from the enclosure port. The reference application is not enclosed in a box so the enclosure port is not indentified with physical surfaces. Therefore, some test cases cannot be applied. Only the antenna port is identified as accessible for direct ESD exposure. The reference application implements all precautions described in the sections below. ESD immunity test results and applicability are reported in Table 20 according to test requirements [12], [12] and [14]. CDMA-2X-11004-3 Preliminary Design-In Page 35 of 43 LISA-C200 & FW75-C200 - System Integration Manual Category Application Immunity Level Contact Discharge to coupling planes (indirect contact discharge) Enclosure +2 kV / -2 kV +4 kV / -4 kV Contact Discharges to conducted surfaces (direct contact discharge) Enclosure port Not Applicable Contact Discharges to conducted surfaces (direct contact discharge) Antenna port Not Applicable6 (only antenna with completely insulating surface can be used) Air Discharge at insulating surfaces Enclosure port Not Applicable Air Discharge at insulating surfaces Antenna port +2 kV / -2 kV (only antenna with completely insulating surface can be used) +4 kV / -4 kV +8 kV / -8 kV Table 20: Enclosure ESD immunity level result, standards “EN 61000-4-2, EN 301 489-1 V1.8.1, EN 301 489-7 V1.3.1” for LISA application reference design. 2.5.1 General precautions The following module interfaces can have a critical influence in ESD immunity testing, depending on the application board handling. The following precautions are suggested: HW_SHUTDOWN pin (FW75-C200 only) Sensitive interface is the reset line (HW_SHUTDOWN pin): A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470JA01) have to be mounted on the line termination connected to the HW_SHUTDOWN pin to avoid a module reset caused by an electrostatic discharge applied to the application board enclosure A series ferrite bead (e.g. Murata BLM15HD182SN1) must be added on the line connected to the HW_SHUTDOWN pin to avoid a module reset caused by an electrostatic discharge applied to the application board enclosure It is recommended to keep the connection line to HW_SHUTDOWN as short as possible Reset_N pin (LISA-C200 only) Sensitive interface is the reset line (Reset_N pin): A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470JA01) have to be mounted on the line termination connected to the Reset_N pin to avoid a module reset caused by an electrostatic discharge applied to the application board enclosure A series ferrite bead (e.g. Murata BLM15HD182SN1) must be added on the line connected to the Reset_N pin to avoid a module reset caused by an electrostatic discharge applied to the application board enclosure It is recommended to keep the connection line to Reset_N as short as possible LISA mounted on application design: Not Applicability -> EUT with insulating enclosure surface, EUT without enclosure surface Applicability -> EUT with conductive enclosure surface LISA mounted on application design: Not Applicability -> Antenna with insulating surface Applicability -> Antenna with conductive surface LISA mounted on application design: Applicability -> EUT with insulating enclosure surface Not Applicability -> EUT with conductive enclosure surface, EUT without enclosure surface CDMA-2X-11004-3 Preliminary Design-In Page 36 of 43 LISA-C200 & FW75-C200 - System Integration Manual u-blox C200 Reset push button FB1 HW_SHUTDOWN ESD C1 Application Processor u-blox C200 Open Drain Output FB2 HW_SHUTDOWN C2 Figure 19: HW_SHUTDOWN application circuits for ESD immunity test Reference Description Remarks ESD Varistor for ESD protection. CT0402S14AHSG - EPCOS C1, C2 47 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H470JA01 - Murata FB1, FB2 Chip Ferrite Bead for Noise/EMI Suppression BLM15HD182SN1 - Murata Rint 10 kΩ Resistor 0402 5% 0.1 W Internal pull-up resistor Table 21: Example of components as ESD immunity test precautions for the HW_SHUTDOWN line SIM interface Sensitive interface is the SIM interface (VSIM pin, SIM_RST pin, SIM_IO pin, SIM_CLK pin): A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470J) have to be mounted on the lines connected to VSIM, SIM_RST, SIM_IO and SIM_CLK to assure SIM interface functionality when an electrostatic discharge is applied to the application board enclosure It is suggested to use as short as possible connection lines at SIM pins SIM card interface is hardware ready but not supported by the current software 2.5.2 Antenna interface precautions The antenna interface ANT can have a critical influence on the ESD immunity test depending on the application board handling. Antenna precaution suggestions are provided: If the device implements an embedded antenna and the device insulating enclosure avoids air discharge up to +8 kV / -8 kV to the antenna interface, no further precautions to ESD immunity test should be needed If the device implements an external antenna and the antenna and its connecting cable are provided with a completely insulating enclosure to avoid air discharge up to +8 kV / -8 kV to the whole antenna and cable surfaces, no further precautions to ESD immunity test should be needed CDMA-2X-11004-3 Preliminary Design-In Page 37 of 43 LISA-C200 & FW75-C200 - System Integration Manual If the device implements an external antenna and the antenna or its connecting cable are not provided with completely insulating enclosure to avoid air discharge up to +8 kV / -8 kV to the whole antenna and cable surfaces, the following precautions to ESD immunity test should be implemented on the application board A higher protection level is required at the ANT port if the line is externally accessible on the application board. ESD immunity test requires protection up to +4 kV / -4 kV for direct Contact Discharge and up to +8 kV / -8 kV for Air Discharge applied to the antenna port. 2.5.3 Module interfaces precautions All the module pins that are externally accessible should be included in the ESD immunity test since they are considered to be a port as defined in [12]. Depending on applicability, and in order to satisfy ESD immunity test requirements and ESD category level, pins connected to the port should be protected up to +4 kV / -4 kV for direct Contact Discharge, and up to +8 kV / -8 kV for Air Discharge applied to the enclosure surface. The maximum ESD sensitivity rating of all the pins of the module, except the ANT pin, is 1 kV (Human Body Model according to JESD22-A114F). A higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array or CT0402S14AHSG). For the USB interface a very low capacitance (i.e. less or equal to 1 pF) ESD protection (e.g. Tyco Electronics PESD0402-140 ESD protection device) can be mounted on the lines connected to USB_D+ and USB_D- pins. For the SIM interface a low capacitance (i.e. less than 10 pF) ESD protection (e.g. Infineon ESD8V0L2B-03L or AVX USB0002) must be placed near the SIM card holder on each line (VSIM, SIM_IO, SIM_CLK, SIM_RST). CDMA-2X-11004-3 Preliminary Design-In Page 38 of 43 LISA-C200 & FW75-C200 - System Integration Manual 3 Features description 3.1 Firmware (upgrade) Over The Air (FOTA LISA-C200 & FW75-C200 modules will support this feature. Sprint Carrier requirement. Not supported nor required for Verizon Carrier. 3.2 UDP/IP LISA-C200 & FW75-C200 modules will support this feature in the upcoming FW version. 3.3 HTTP LISA-C200 & FW75-C200 modules will support this feature in the upcoming FW version. CDMA-2X-11004-3 Preliminary Features description Page 39 of 43 LISA-C200 & FW75-C200 - System Integration Manual Appendix A Glossary ADC Analog to Digital Converter AP Application Processor AT AT Command Interpreter Software Subsystem, or attention CBCH Cell Broadcast Channel CS Coding Scheme CSD Circuit Switched Data CTS Clear To Send DC Direct Current DCD Data Carrier Detect DCE Data Communication Equipment DCS Digital Cellular System DDC Display Data Channel DSP Digital Signal Processing DSR Data Set Ready DTE Data Terminal Equipment DTM Dual Transfer Mode DTR Data Terminal Ready EBU External Bus Interface Unit CDMA CODE Division Multiple Access FDD Frequency Division Duplex FEM Front End Module FOAT Firmware Over AT commands FTP File Transfer Protocol FTPS FTP Secure GND Ground GPIO General Purpose Input Output GPS Global Positioning System HF Hands-free HTTP HyperText Transfer Protocol HTTPS Hypertext Transfer Protocol over Secure Socket Layer HW Hardware I/Q IC In phase and Quadrature Inter-Integrated Circuit IS Inter IC Sound IP Internet Protocol IPC Inter Processor Communication LNA Low Noise Amplifier MCS Modulation Coding Scheme NOM Network Operating Mode CDMA-2X-11004-3 Preliminary Appendix Page 40 of 43 LISA-C200 & FW75-C200 - System Integration Manual PA Power Amplifier PBCCH Packet Broadcast Control Channel PCM Pulse Code Modulation PCS Personal Communications Service PFM Pulse Frequency Modulation PMU Power Management Unit RF Radio Frequency RI Ring Indicator RTC Real Time Clock RTS Request To Send RXD RX Data SAW Surface Acoustic Wave SIM Subscriber Identification Module SMS Short Message Service SMTP Simple Mail Transfer Protocol SRAM Static RAM TCP TDMA Transmission Control Protocol Time Division Multiple Access TXD TX Data UART Universal Asynchronous Receiver-Transmitter UDP User Datagram Protocol USB Universal Serial Bus CDMA-2X-11004-3 Preliminary Appendix Page 41 of 43 LISA-C200 & FW75-C200 - System Integration Manual Related documents [1] [2] [3] LISA-C200 Data Sheet, Docu No CDMA-2X-11001 FW75 Data Sheet, Docu No CDMA-1X-11006 u-blox C200 AT Commands Manual, Docu No CDMA-2X-11002 [4] ITU-T Recommendation V.24, 02-2000. List of definitions for interchange circuits between data terminal equipment (DTE) and data circuit-terminating equipment (DCE). http://www.itu.int/rec/T-REC-V.24-200002-I/en 3GPP TS 27.007 - AT command set for User Equipment (UE) (Release 1999) 3GPP TS 27.005 - Use of Data Terminal Equipment - Data Circuit terminating; Equipment (DTE - DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS) (Release 1999) 3GPP TS 27.010 - Terminal Equipment to User Equipment (TE-UE) multiplexer protocol (Release 1999) 3GPP TS 23.060 - General Packet Radio Service (GPRS); Service description; Stage 2 (Release 1999) Universal Serial Bus Revision 2.0 specification, http://www.usb.org/developers/docs/ [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] I2C-Bus Specification Version 2.1 Philips Semiconductors (January 2000), http://www.nxp.com/acrobat_download/literature/9398/39340011_21.pdf GPS Implementation Application Note, Docu No GSM.G1-CS-09007 CENELEC EN 61000-4-2 (2001): “Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test”. ETSI EN 301 489-1 V1.8.1: “Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements” ETSI EN 301 489-7 V1.3.1 “Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS)“ Some of the above documents can be downloaded from u-blox web-site (http://www.u-blox.com). Revision history Revision Date Name Status / Comments 11/24/11 rcam Initial Release 5/23/2012 smoi Updated product names 7/9/2012 smoi Unification of SIM nomenclature 8/20/2012 smoi Document status change CDMA-2X-11004-3 Preliminary Related documents Page 42 of 43 LISA-C200 & FW75-C200 - System Integration Manual Contact For complete contact information visit us at www.u-blox.com u-blox Offices North, Central and South America u-blox America, Inc. Phone: +1 (703) 483 3180 E-mail: info_us@u-blox.com Regional Office West Coast: Phone: +1 (703) 483 3184 E-mail: info_us@u-blox.com Headquarters Europe, Middle East, Africa u-blox AG Phone: +41 44 722 74 44 E-mail: info@u-blox.com Support: support @u-blox.com Technical Support: Phone: E-mail: +1 (703) 483 3185 support_us@u-blox.com Asia, Australia, Pacific u-blox Singapore Pte. Ltd. Phone: +65 6734 3811 E-mail: info_ap@u-blox.com Support: support_ap@u-blox.com Regional Office China: Phone: +86 10 68 133 545 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office Japan: Phone: +81 3 5775 3850 E-mail: info_jp@u-blox.com Support: support_jp@u-blox.com Regional Office Korea: Phone: +82 2 542 0861 E-mail: info_kr@u-blox.com Support: support_kr@u-blox.com Regional Office Taiwan: Phone: +886 2 2657 1090 E-mail: info_tw@u-blox.com Support: support_tw@u-blox.com CDMA-2X-11004-3 Preliminary Contact Page 43 of 43
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : alaudani Create Date : 2012:12:19 15:09:02-08:00 Modify Date : 2012:12:19 15:09:02-08:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : alaudani Title : Microsoft Word - LISAC200-FW75C200_SystemIntegrationManual_(CDMA-2X-11004).docx Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 10.1.4 (Windows) Document ID : uuid:b9508aac-0012-419b-bbd6-fe56277208b0 Instance ID : uuid:62fada52-f3f0-49c1-9c09-75cbca7671a2 Page Count : 43EXIF Metadata provided by EXIF.tools