u blox San Diego LISAC200A CDMA 1xRTT Cellular Module User Manual

u-blox San Diego, Inc. CDMA 1xRTT Cellular Module Users Manual

Contents

Users Manual

Download: u blox San Diego LISAC200A CDMA 1xRTT Cellular Module User Manual
Mirror Download [FCC.gov]u blox San Diego LISAC200A CDMA 1xRTT Cellular Module User Manual
Document ID1864736
Application IDvqY9BpFEpUfczveILcdSfg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize56.2kB (702445 bits)
Date Submitted2012-12-20 00:00:00
Date Available2012-12-20 00:00:00
Creation Date2012-12-19 15:09:02
Producing SoftwareAcrobat Distiller 10.1.4 (Windows)
Document Lastmod2012-12-19 15:09:02
Document TitleMicrosoft Word - LISAC200-FW75C200_SystemIntegrationManual_(CDMA-2X-11004).docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: alaudani

CDMA 1xRTT
Wireless Modules
System Integration Manual
Abstract
This document describes the features and the integration of
u-blox LISA-C200 and FW75-C200 CDMA2000 1xRTT wireless
modules.
These modules are complete and cost efficient CDMA solutions
offering 153 kb/s data speed dual-band 800/1900 MHz data
transmission technology in compact form factors.
www.u-blox.com
locate, communicate, accelerate
LISA-C200 & FW75-C200
LISA-C200 & FW75-C200 - System Integration Manual
Document Information
Title
LISA-C200 & FW75-C200
Subtitle
CDMA 1xRTT
Wireless Modules
Document type
System Integration Manual
Document number
CDMA-2X-11004-3
Document status
Preliminary
Document status information
This document contains target values. Revised and supplementary data will be published
Objective
Specification
later.
This document contains data based on early testing. Revised and supplementary data will
Advance
Information
be published later.
Preliminary
This document contains data from product verification. Revised and supplementary data
may be published later.
Released
This document contains the final product specification.
This document applies to the following products:
Name
Type number
Firmware version
PCN / IN
LISA-C200
LISA-C200
FW75-C200
FW75-C200
LISA-C200-01S
LISA-C200-21S
FW-C200-01S
FW-C200-21S
E0.S.03.00.10R
E0.V.03.00.02R
E0.S.03.00.10R
E0.V.03.00.02R
UBX-TN-12041
UBX-TN-12041
UBX-TN-12041
UBX-TN-12041
This document and the use of any information contained therein, is subject to the acceptance of the u-blox terms and conditions. They
can be downloaded from www.u-blox.com.
u-blox makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to mak e
changes to specifications and product descriptions at any time without notice.
u-blox reserves all rights to this document and the information contained herein. Reproduction, use or disclosure to third parties without
express permission is strictly prohibited. Copyright © 2012, u-blox AG.
®
u-blox is a registered trademark of u-blox Holding AG in the EU and other countries.
CDMA-2X-11004-3
Page 2 of 43
LISA-C200 & FW75-C200 - System Integration Manual
Preface
u-blox Technical Documentation
As part of our commitment to customer support, u-blox maintains an extensive volume of technical
documentation for our products. In addition to our product-specific technical data sheets, the following manuals
are available to assist u-blox customers in product design and development.
AT Commands Manual: This document provides the description of the supported AT commands by the
LISA-C200 & FW75-C200 module to verify all implemented functionalities.
System Integration Manual: This Manual provides hardware design instructions and information on how to
set up production and final product tests.
Application Note: document provides general design instructions and information that applies to all u-blox
Wireless modules. See Section Related documents for a list of Application Notes related to your Wireless
Module.
How to use this Manual
The LISA-C200 & FW75-C200 System Integration Manual provides the necessary information to successfully
design in and configure these u-blox wireless modules.
This manual has a modular structure. It is not necessary to read it from the beginning to the end.
The following symbols are used to highlight important information within the manual:
An index finger points out key information pertaining to module integration and performance.
A warning symbol indicates actions that could negatively impact or damage the module.
Questions.
If you have any questions about u-blox Wireless Integration, please:
Read this manual carefully.
Contact our information service on the homepage http://www.u-blox.com
Read the questions and answers on our FAQ database on the homepage http://www.u-blox.com
Technical Support
Worldwide Web
Our website (www.u-blox.com) is a rich pool of information. Product information, technical documents and
helpful FAQ can be accessed 24h a day.
By E-mail
Contact the nearest Technical Support office by email. Use our service pool email addresses rather than any
personal email address of our staff. This makes sure that your request is processed as soon as possible. You will
find the contact details at the end of the document.
Helpful Information when Contacting Technical Support
When contacting Technical Support please have the following information ready:
Module type (e.g. LISA-C200) and firmware version
Module configuration
Clear description of your question or the problem
A short description of the application
Your complete contact details
CDMA-2X-11004-3
Preliminary
Preface
Page 3 of 43
LISA-C200 & FW75-C200 - System Integration Manual
Contents
Preface ................................................................................................................................3
Contents..............................................................................................................................4
System description .......................................................................................................6
1.1
Overview .............................................................................................................................................. 6
Architecture.......................................................................................................................................... 7
1.2
Functional blocks........................................................................................................................... 7
1.2.1
1.3
Pin description ...................................................................................................................................... 8
1.4
Power management ........................................................................................................................... 10
1.4.1
Power supply circuit overview ...................................................................................................... 10
1.4.2
Module supply (VCC) .................................................................................................................. 11
1.4.3
Current consumption profiles ...................................................................................................... 17
System functions ................................................................................................................................ 18
1.5
1.5.1
Module power on ....................................................................................................................... 18
1.5.2
Module power off ....................................................................................................................... 20
1.5.3
Module reset ............................................................................................................................... 20
1.6
RF connection ..................................................................................................................................... 20
Serial communication ......................................................................................................................... 21
1.7
Serial interfaces configuration ..................................................................................................... 21
1.7.1
1.7.2
Asynchronous serial interface (UART)........................................................................................... 22
USB interface............................................................................................................................... 24
1.7.3
1.7.4
MUX Protocol (3GPP 27.010) ...................................................................................................... 25
1.8
Reserved pins (RSVD) .......................................................................................................................... 25
Schematic for LISA-C200 and FW75-C200 modules integration ......................................................... 26
1.9
Approvals........................................................................................................................................ 27
1.10
1.10.1 Declaration of Conformity for products marked with the FCC logo - United States only .............. 27
1.10.2 Modifications .............................................................................................................................. 27
Design-In .....................................................................................................................28
2.1
Design-in checklist .............................................................................................................................. 28
2.1.1
Schematic checklist ..................................................................................................................... 28
2.1.2
Antenna checklist ........................................................................................................................ 28
2.2
Connectors (FW75) ............................................................................................................................. 29
2.2.1
FW75-C200 modem connector ................................................................................................... 29
FW75-C200 Board to Board host connector ................................................................................ 29
2.2.2
FW75-C200 RF antenna connector.............................................................................................. 30
2.2.3
2.3
Design Guidelines ............................................................................................................................... 31
2.3.1
Layout guidelines per pin function ............................................................................................... 31
2.4
Antenna guidelines ............................................................................................................................. 32
2.4.1
Antenna termination ................................................................................................................... 33
CDMA-2X-11004-3
Preliminary
Contents
Page 4 of 43
LISA-C200 & FW75-C200 - System Integration Manual
2.4.2
Antenna radiation ....................................................................................................................... 34
ESD immunity test precautions ........................................................................................................... 35
2.5
General precautions .................................................................................................................... 36
2.5.1
2.5.2
Antenna interface precautions..................................................................................................... 37
2.5.3
Module interfaces precautions..................................................................................................... 38
Features description...................................................................................................39
3.1
3.2
3.3
Firmware (upgrade) Over The Air (FOTA.............................................................................................. 39
UDP/IP ................................................................................................................................................ 39
HTTP................................................................................................................................................... 39
Appendix ..........................................................................................................................40
A Glossary ......................................................................................................................40
Related documents...........................................................................................................42
Revision history ................................................................................................................42
Contact ..............................................................................................................................43
CDMA-2X-11004-3
Preliminary
Contents
Page 5 of 43
LISA-C200 & FW75-C200 - System Integration Manual
1 System description
1.1 Overview
u-blox C200 wireless modules integrate a complete CDMA 1xRTT 153 kb/s packet data modem into a single
module solution. These modems are certified to operate on US CDMA carriers. In addition they can operate on
carriers requiring a SIM data card interface.
3G CDMA 2000 1xRTT Characteristics
CDMA Terrestrial Radio Access Frequency Division Duplex (FDD)
operating mode
Dual-band support:
Band Class 0 – US Cellular
Band Class 1 – US PCS
CDMA Packet Switched data up to 153 kb/s DL/UL
Table 1: 3G CDMA 2000 1xRTT characteristics
These modems are US CDMA certified to support 1xRTT data speeds on US CDMA carriers Sprint and Verizon.
FW75-C200 is strictly a data modem for embedded solutions while LISA-C200 also supports audio (analog and
digital) functionality. Data communication is through 2 data interfaces; 5 wires UART and Full Speed USB. The
interfaces are intended to support a vast quantity of AT commands that will enable easy adoption to existing
host application processors.
Power on is initiated by HW logic and Power down by HW logic and SW control.
LISA-C200 antenna interface is provided through a 50 ohm pad while FW75-C200 uses the popular “U.FL” RF
connector.
Other key components are the extensive SW AT commands meeting the needs of :
Carrier AT commands
Industry standard AT command both 3GPP and 3GPP2
u-blox AT Commands
CDMA-2X-11004-3
Preliminary
System description
Page 6 of 43
LISA-C200 & FW75-C200 - System Integration Manual
1.2 Architecture
ANT
Digital and
analog voice (**)
Diplexer
RF
Transceiver
UART
3G PA
19.2 MHz
3G PA
LNA
SAW
Filter
32.768 kHz
Wireless
Base-band
Processor
USB
GPIOs (**)
LNA
Memory
Power On
Vcc (Supply)
Power Management Unit
HW shutdown (*)
HW Reset (**)
V_INT (I/O)
(*): FW75
(**): LISA-C200
Figure 1: Block diagram
1.2.1 Functional blocks
LISA-C200 & FW75-C200 modules consist of the following internal functional blocks: RF front-end, RF
transceiver, Baseband section and Power Management Unit.
RF Front-End
The Antenna connector is directly connected to the Diplexer which separates the 800 and 1900 MHZ bands.
Each 800 & 1900 MHz RF chain are connected to their respective transceiver paths via duplexers as shown in
prior block diagram.
Each duplexer provides the filtering and Rx/Tx path separation before connecting to the LNA and RF PA devices.
A separate shield compartment houses the 800 MHZ and 1900 MHZ RF power amplifiers. This compartment
provides high Tx signal isolation, preventing de-sensing of the Rx frontend circuitry.
RF Transceiver
The transceiver includes the following key components:
Dual-band 800 & 1900 MHz CDMA transceiver, excluding the RF Power Amplifiers, duplexers and diplexer.
19.2 MHz Crystal Oscillator
While operating, the RF transceiver performs direct up-conversion and down-conversion of the baseband I/Q
signals, with the RF voltage controlled gain amplifier being used to set the uplink TX power. In the downlink
path, the internal LNA enhances the RX sensitivity. An internal automatic gain control amplifier optimizes the
signal levels before delivering to the analog I/Q to baseband for further digital processing.
CDMA-2X-11004-3
Preliminary
System description
Page 7 of 43
LISA-C200 & FW75-C200 - System Integration Manual
In all the modes, Tx & Rx RF synthesizers are an on-chip voltage controlled oscillator are used to generate the
local oscillator signal.
The frequency reference to RF synthesizers are provided by a free running 19.2 MHz XO. The Rx path locks and
tracks to the base station carrier. An learning algorithm is implemented to capture the temperature characteristic
of the xtal, comparing the XO and carrier frequencies, while measuring the thermistor in close proximity to the
crystal oscillator. A lookup table is saved over temperature and time. The known frequency difference of the
free running crystal oscillator is corrected in the baseband processor enabling quick acquisition.
Baseband section and power management unit
Another shielding section includes all the digital circuitry and the power supplies, basically the following
functional blocks:
Wireless baseband processor, a mixed signal ASIC which integrates:
Microprocessor for controller functions, CDMA upper layer software
ARM9 coprocessor and HW accelerator for CDMA Layer 1 control software and routines
Dedicated HW for peripherals control, as UART, USB, etc
Memory system in a Multi-Chip Package (MCP) integrating two devices:
NOR flash non-volatile memory
DDR SRAM volatile memory
Power Management Unit (PMU), used to derive all the system supply voltages from the module supply VCC
1.3 Pin description
Table 2 provides a summary of the module pin names and descriptions.
For the exact specification including pin numbering and additional information see the LISA-C200 Data
Sheet [1] or the FW75-C200 Data Sheet [2].
Name
Module
Power
domain
I/O
Description
Remarks
VCC
All
VCC
Module supply
Module supply input
V_INT
FW75-C200
Digital I/O Interfaces supply
output
LISA-C200
Digital I/O Interfaces supply
output
V_INT = 2.85V (typical) generated by the module
when it is switched-on and the RESET_N (external
reset input pin) is not forced to the low level.
V_INT = 1.8V (typical) generated by the module
when it is switched-on and the RESET_N (external
reset input pin) is not forced to the low level.
PWR_ON
All
POS
Power-on input
PWR_ON pin has Internal pull-up resistor.
GPIO1..10
LISA-C200
GDI
I/O
GPIO
GPIO6..10 Reserved.
RESET_N
LISA-C200
ERS
External reset input
RESET_N pin has Internal pull-up resistor.
HW_SHUTDOWN
FW75-C200
ERS
External Shutdown input
HW_SHUTDOWN pin has Internal pull-up resistor.
ANT
All
ANT
I/O
RF antenna
STATUS
FW75-C200
GDI
LED Indicator
Indicated by buffered External LED :
Off – Not Powered
On – Powered, associated, and authenticated but
not transmitting or receiving.
Slow Blink but not associated or authenticated;
searching.
Intermittent Blink - activity proportional to
transmitting/receiving speed. For voice
applications, turning off and on the
intermittent blink based on the ring pulse
cycle can indicate a ring event.
CDMA-2X-11004-3
Preliminary
System description
Page 8 of 43
LISA-C200 & FW75-C200 - System Integration Manual
Name
Module
RI
Power
domain
GDI
I/O
Description
Remarks
UART ring indicator
Circuit 125 (RI) in ITU-T V.24.
Value at internal reset: T/PU.
Use to wake up host processor. The output signal
is active low.
Internal active pull-up to 1.8 V.
Internal active pull-up to 2.85 V
GDI
UART clear to send
Circuit 106 (CTS) in ITU-T V.24.
Internal active pull-up to 1.8 V.
Internal active pull-up to 2.85 V.
GDI
UART ready to send
GDI
UART received data
GDI
UART transmitted data
Circuit 105 (RTS) in ITU-T V.24.
Internal passive pull-up to 1.8 V.
Internal passive pull-up to 2.85 V.
Circuit 104 (RxD) in ITU-T V.24.
Internal active pull-up to 1.8 V.
Internal active pull-up to 2.85 V.
Circuit 103 (TxD) in ITU-T V.24.
Internal passive pull-up to 1.8 V.
Internal passive pull-up to 2.85 V.
LISA-C200
FW75-C200
CTS
LISA-C200
FW75-C200
RTS
LISA-C200
FW75-C200
RXD
LISA-C200
FW75-C200
TXD
LISA-C200
FW75-C200
VUSB_DET
All
USB
USB detect input
Input for VBUS (5 V typical) USB supply sense.
USB_D-
All
USB
I/O
USB Data Line D-
90 Ω nominal differential impedance.
Pull-up or pull-down resistors and external series
resistors as required by the USB 2.0 high-speed
specification [9] are part of the USB pad driver
and need not be provided externally.
USB_D+
All
USB
I/O
USB Data Line D+
90 Ω nominal differential impedance.
Pull-up or pull-down resistors and external series
resistors as required by the USB 2.0 high-speed
specification [9] are part of the USB pad driver
and need not be provided externally.
MIC_N
LISA-C200
AUDIO
Differential analog audio
input (negative)
MIC_P
LISA-C200
AUDIO
Differential analog audio
input (positive)
Differential analog microphone input.
Internal DC blocking 0.1 µF capacitor.
Differential analog microphone input.
Internal DC blocking 0.1 µF capacitor.
SPK_P
LISA-C200
AUDIO
Differential analog audio
output (positive)
SPK_N
LISA-C200
AUDIO
Differential analog audio
output (negative)
PCM_SYNC
LISA-C200
GDI
Digital Sync
Differential analog audio output shared for all
path modes: earpiece, headset and loudspeaker
mode.
Differential analog audio output shared for all
path modes: earpiece, headset and loudspeaker
mode.
Digital Audio Sync pulse.
PCM_DO
LISA-C200
GDI
Data Output
Digital Audio Output.
PCM_CLK
LISA-C200
GDI
Clock Output
Digital Audio Clock Output.
PCM_DI
LISA-C200
GDI
Data Input
SCL
LISA-C200
DDC
I C bus clock line
SDA
LISA-C200
DDC
I/O
I2C bus data line
SIM_CLK
All
SIM
SIM clock
SIM_IO
All
SIM
I/O
SIM data
SIM_RST
All
SIM
SIM reset
VSIM
ALL
SIM supply output
SIM_GND
FW75-C200
SIM
SIM GROUND
RSVD
All
RSVD
RESERVED pin
Unless otherwise specified, leave unconnected.
GND
All
GND
Ground
All GND pads must be connected to ground.
Digital Audio Input.
Fixed open drain. No internal pull-up.
Value at internal reset: T.
Fixed open drain. No internal pull-up.
Value at internal reset: T.
Value at internal reset: L.
Internal 4.7 kΩ pull-up resistor to VSIM.
Value at internal reset: L/PD.
Value at internal reset: L.
1.80 V typical or 2.90 V typical generated by the
module according to the SIM card type.
Table 2: Pin description summary
CDMA-2X-11004-3
Preliminary
System description
Page 9 of 43
LISA-C200 & FW75-C200 - System Integration Manual
1.4 Power management
1.4.1 Power supply circuit overview
LISA-C200 & FW75-C200 modules feature a power management concept optimized for the most efficient use of
supplied power. This is achieved by hardware design utilizing a power efficient circuit topology (Figure 2), and by
power management software controlling the module’s power saving mode.
2 x 3G Power Amplifier(s)
u-blox C200
Memory
NOR Flash
RF Transceiver
DDR SRAM
Linear
LDO
VCC
Linear
LDO
EBU
Switching
Step-Down
I/O
Switching
Step-Down
CORE
Linear
LDO
Analog
Linear
LDO
SIM
Linear
LDO
RTC
42 µF
VCC
VCC
Power Management Unit
Baseband Processor
V_INT
VSIM
4.7 µF
2.2 µF
Figure 2: Power management simplified block diagram
Pins with supply function are reported in Table 3.
LISA-C200 & FW75-C200 modules must be supplied via the VCC pins. There is only one main power supply
input, available on the three1 or five2 VCC pins that must be all connected to the external power supply
LISA-C200.
CDMA-2X-11004-3
Preliminary
System description
Page 10 of 43
LISA-C200 & FW75-C200 - System Integration Manual
The VCC pins are directly connected to the RF power amplifiers and to the integrated Power Management Unit
(PMU) within the module: all supply voltages needed by the module are generated from the VCC supply by
integrated voltage regulators.
When a 1.8 V or a 3 V SIM card type is connected, LISA-C200 & FW75-C200 modules automatically supply the
SIM card via the VSIM pin. Activation and deactivation of the SIM interface with automatic voltage switch from
1.8 to 3 V is implemented, in accordance to the ISO-IEC 7816-3 specifications.
The 2.8 voltage domain used internally also available on the V_INT pin, to allow more economical and efficient
integration of the LISA-C200 & FW75-C200 modules in the final application.
The integrated Power Management Unit also provides the control state machine for system start up and system
shut down control.
1.4.2 Module supply (VCC)
LISA-C200 & FW75-C200 modules must be supplied through the VCC pins by a DC power supply. Voltages must
be stable: during operation, the current drawn from VCC can vary by some orders of magnitude.
Name
Description
Remarks
VCC
Module power supply input
VCC pins are internally connected, but all the available pads
or pins must be connected to the external supply in order to
minimize the power loss due to series resistance.
Clean and stable supply is required: low ripple and low
voltage drop must be guaranteed.
Voltage provided must always be above the minimum limit of
the operating range.
GND
Ground
GND pins are internally connected but a good (low
impedance) external ground can improve RF performance: all
available pads or pins must be connected to ground.
Table 3: Module supply pins
Higher ESD protection level can be required if VCC is externally accessible on the application board.
Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG
varistor array) on the line connected to this pin.
The voltage provided to the VCC pins must be within the normal operating range limits as specified in
the LISA-C200 Data Sheet [1] or FW75-C200 Data Sheet [2]. Complete functionality of the module is
only guaranteed within the specified minimum and maximum VCC voltage operating range.
Ensure that the input voltage at the VCC pins never drops below the minimum limit of the operating
range when the module is switched on.
Operation above the operating range maximum limit is not recommended and extended
exposure beyond it may affect device reliability.
Stress beyond the VCC absolute maximum ratings can cause permanent damage to the module:
if necessary, voltage spikes beyond VCC absolute maximum ratings must be restricted to values
within the specified limits by using appropriate protection.
When designing the power supply for the application, pay specific attention to power losses and
transients. The DC power supply must be able to provide a voltage profile to the VCC pins with the
following characteristics:
Voltage drop during transmission must be lower than 250 mV
FW75-C200.
CDMA-2X-11004-3
Preliminary
System description
Page 11 of 43
LISA-C200 & FW75-C200 - System Integration Manual
Any degradation in power supply performance (due to losses, noise or transients) will directly affect the
RF performance of the module since the single external DC power source indirectly supplies all the
digital and analog interfaces, and also directly supplies the RF power amplifier (PA).
1.4.2.1 VCC application circuits
LISA-C200 & FW75-C200 modules must be supplied through the VCC pins by one (and only one) proper DC
power supply that must be one of the following:
Switching regulator
Low Drop-Out (LDO) linear regulator
Rechargeable Li-Ion battery
Primary (disposable) battery
Main Supply
Available?
No, portable device
Battery
Li-Ion 3.7 V
Yes, always available
Main Supply
Voltage
>5 V?
No, less than 5 V
Linear LDO
Regulator
Yes, greater than 5 V
Switching
Step-Down
Regulator
Figure 3: VCC supply concept selection
The switching step-down regulator is the typical choice when the available primary supply source has a nominal
voltage much higher (e.g. greater than 5 V) than the LISA-C200 & FW75-C200 modules operating supply
voltage. The use of switching step-down provides the best power efficiency for the overall application and
minimizes current drawn from the main supply source.
The use of an LDO linear regulator becomes convenient for a primary supply with a relatively low voltage (e.g.
less than 5 V). In this case the typical 90% efficiency of the switching regulator will diminish the benefit of
voltage step-down and no true advantage will be gained in input current savings. On the opposite side, linear
regulators are not recommended for high voltage step-down as they will dissipate a considerable amount of
energy in thermal power.
If LISA-C200 & FW75-C200 modules are deployed in a mobile unit where no permanent primary supply source is
available, then a battery will be required to provide VCC. A standard 3-cell Lithium-Ion battery pack directly
connected to VCC is the usual choice for battery-powered devices. During charging, batteries with Ni-MH
chemistry typically reach a maximum voltage that is above the maximum rating for VCC, and should therefore be
avoided.
The use of primary (not rechargeable) battery is uncommon, since the most cells available are seldom capable of
delivering the peak current due to high internal resistance.
Keep in mind that the use of batteries requires the implementation of a suitable charger circuit (not included in
LISA-C200 & FW75-C200 modules). The charger circuit should be designed in order to prevent over-voltage on
VCC beyond the upper limit of the absolute maximum rating.
The following sections highlight some design aspects for each of the supplies listed above.
CDMA-2X-11004-3
Preliminary
System description
Page 12 of 43
LISA-C200 & FW75-C200 - System Integration Manual
Switching regulator
The characteristics of the switching regulator connected to VCC pins should meet the following requirements:
Power capability: the switching regulator with its output circuit must be capable of providing a voltage
value to the VCC pins within the specified operating range and must be capable of delivering greater than
1.2 Amps for safe design margin
Low output ripple: the switching regulator together with its output circuit must be capable of providing a
clean (low noise) VCC voltage profile
High switching frequency: for best performance and for smaller applications select a switching frequency
≥ 600 kHz (since L-C output filter is typically smaller for high switching frequency). The use of a switching
regulator with a variable switching frequency or with a switching frequency lower than 600 kHz must be
carefully evaluated since this can produce noise in the VCC voltage profile. An additional L-C low-pass filter
between the switching regulator output to VCC supply pins can mitigate the ripple on VCC, but adds extra
voltage drop due to resistive losses on series inductors
PWM mode operation: select preferably regulators with Pulse Width Modulation (PWM) mode. While in
active mode Pulse Frequency Modulation (PFM) mode and PFM/PWM mode transitions must be avoided to
reduce the noise on the VCC voltage profile. Switching regulators able to switch between low ripple PWM
mode and high efficiency burst or PFM mode can be used, provided the mode transition from idle mode
(current consumption approximately 2 mA) to active mode (current consumption approximately 100 mA): it
is permissible to use a regulator that switches from the PWM mode to the burst or PFM mode at an
appropriate current threshold (e.g. 60 mA)
Output voltage slope: ( not necessary for CDMA solution, ok to delete-RJC) the use of the soft start
function provided by some voltage regulator must be carefully evaluated, since the voltage at the VCC pins
must ramp from 2.5 V to 3.2 V within 1 ms to allow a proper switch-on of the module
Figure 4 and the components listed in Table 4 show an example of a high reliability power supply circuit, where
the module VCC is supplied by a step-down switching regulator capable of delivering 2.5 A current pulses with
low output ripple and with fixed switching frequency in PWM mode operation greater than 1 MHz. The use of a
switching regulator is suggested when the difference from the available supply rail to the VCC value is high:
switching regulators provide good efficiency transforming a 12 V supply to the typical 3.8 V value of the VCC
supply.
12V
u-blox C200
VIN
R1
RUN
BD
BOOST
VC
10 RT
C1
R2
C2 C3
C4 C5
7 PG
R3
C6
SW
D1
FB
SYNC
L1
U1
VCC
L2
C7
R4
C8
C9
GND
R5
11
GND
Figure 4: Suggested schematic design for the VCC voltage supply application circuit using a step-down regulator
CDMA-2X-11004-3
Preliminary
System description
Page 13 of 43
LISA-C200 & FW75-C200 - System Integration Manual
Reference
Description
Part Number – Manufacturer
C1
47 µF Capacitor Aluminum 0810 50 V
MAL215371479E3 – Vishay
C2
10 µF Capacitor Ceramic X7R 5750 15% 50 V
C5750X7R1H106MB – TDK
C3
10 nF Capacitor Ceramic X7R 0402 10% 16 V
C4
680 pF Capacitor Ceramic X7R 0402 10% 16 V
GRM155R71C103KA01 – Murata
GRM155R71H681KA01 – Murata
C5
22 pF Capacitor Ceramic COG 0402 5% 25 V
GRM1555C1H220JZ01 – Murata
C6
10 nF Capacitor Ceramic X7R 0402 10% 16 V
GRM155R71C103KA01 – Murata
C7
C8
470 nF Capacitor Ceramic X7R 0603 10% 25 V
22 µF Capacitor Ceramic X5R 1210 10% 25 V
GRM188R71E474KA12 – Murata
C37
330 µF Capacitor Tantalum D_SIZE 6.3 V 45 mΩ
T520D337M006ATE045 - KEMET
D1
Schottky Diode 40 V 3 A
MBRA340T3G - ON Semiconductor
L1
10 µH Inductor 744066100 30% 3.6 A
744066100 - Wurth Electronics
L2
1 µH Inductor 7445601 20% 8.6 A
7445601 - Wurth Electronics
R1
470 kΩ Resistor 0402 5% 0.1 W
2322-705-87474-L - Yageo
R2
15 kΩ Resistor 0402 5% 0.1 W
2322-705-87153-L - Yageo
R3
22 kΩ Resistor 0402 5% 0.1 W
2322-705-87223-L - Yageo
R4
390 kΩ Resistor 0402 1% 0.063 W
RC0402FR-07390KL - Yageo
R5
100 kΩ Resistor 0402 5% 0.1 W
2322-705-70104-L - Yageo
U1
Step Down Regulator MSOP10 3.5 A 2.4 MHz
LT3972IMSE#PBF - Linear Technology
GRM32ER61E226KE15 – Murata
Table 4: Suggested components for the VCC voltage supply application circuit using a step-down regulator
Low Drop-Out (LDO) linear regulator
The characteristics of the LDO linear regulator connected to the VCC pins should meet the following
requirements:
Power capabilities: the LDO linear regulator with its output circuit must be capable of providing a proper
voltage value to the VCC pins and of delivering 1.2 A
Power dissipation: the power handling capability of the LDO linear regulator must be checked to limit its
junction temperature to the maximum rated operating range (i.e. check the voltage drop from the max input
voltage to the min output voltage to evaluate the power dissipation of the regulator)
Figure 5 and the components listed in Table 5 show an example of a power supply circuit, where the VCC
module supply is provided by an LDO linear regulator capable of delivering 1.2 Amps, with proper power
handling capability. The use of a linear regulator is suggested when the difference from the available supply rail
and the VCC value is low: linear regulators provide high efficiency when transforming a 5 V supply to the 3.6 V
typical value of the VCC supply.
u-blox C200
5V
IN
OUT
VCC
U1
C1
R1
R2
SHDN
ADJ
GND
C2
R3
GND
Figure 5: Suggested schematic design for the VCC voltage supply application circuit using an LDO linear regulator
CDMA-2X-11004-3
Preliminary
System description
Page 14 of 43
LISA-C200 & FW75-C200 - System Integration Manual
Reference
Description
Part Number - Manufacturer
C1
10 µF Capacitor Ceramic X5R 0603 20% 6.3 V
GRM188R60J106ME47 - Murata
C2
10 µF Capacitor Ceramic X5R 0603 20% 6.3 V
GRM188R60J106ME47 - Murata
R1
47 kΩ Resistor 0402 5% 0.1 W
RC0402JR-0747KL - Yageo Phycomp
R2
4.7 kΩ Resistor 0402 5% 0.1 W
RC0402JR-074K7L - Yageo Phycomp
R3
2.2 kΩ Resistor 0402 5% 0.1 W
RC0402JR-072K2L - Yageo Phycomp
U1
LDO Linear Regulator ADJ 3.0 A
LT1764AEQ#PBF - Linear Technology
Table 5: Suggested components for VCC voltage supply application circuit using an LDO linear regulator
Rechargeable Li-Ion battery
Rechargeable Li-Ion batteries connected to the VCC pins should meet the following requirements:
Maximum pulse and DC discharge current: the rechargeable Li-Ion battery with its output circuit must be
capable of delivering 1.2 A to the VCC pins and must be capable of delivering a DC current greater than the
module maximum average current consumption to VCC pins. The maximum pulse discharge current and the
maximum DC discharge current are not always reported in battery data sheets, but the maximum DC
discharge current is typically almost equal to the battery capacity in Amp-hours divided by 1 hour
DC series resistance: the rechargeable Li-Ion battery with its output circuit must be capable of avoiding a
VCC voltage drop greater than 250 mV during peak currents (Max Tx Power).
Primary (disposable) battery
The characteristics of a primary (non-rechargeable) battery connected to VCC pins should meet the following
requirements:
Maximum pulse and DC discharge current: the non-rechargeable battery with its output circuit must be
capable of delivering 1.2 A to the VCC pins and must be capable of delivering a DC current greater than the
module maximum average current consumption at the VCC pins. The maximum pulse and the maximum DC
discharge current is not always reported in battery data sheets, but the maximum DC discharge current is
typically almost equal to the battery capacity in Amp-hours divided by 1 hour
DC series resistance: the non-rechargeable battery with its output circuit must be capable of avoiding a
VCC voltage drop greater than 250 mV during peak currents (Max Tx Power).
Additional recommendations for the VCC supply application circuits
To reduce voltage drops, use a low impedance power source. The resistance of the power supply lines
(connected to the VCC and GND pins of the module) on the application board and battery pack should also be
considered and minimized: cabling and routing must be as short as possible in order to minimize power losses.
Three3 or five4 pins are allocated for VCC supply. Another seven pins are designated for GND connection. Even if
all the VCC pins and all the GND pins are internally connected within the module, it is recommended to properly
connect all of them to supply the module in order to minimize series resistance losses.
The placement ceramic capacitors on the VCC line on the main board close to the connector will benefit
operation.
To reduce voltage ripple and noise, place the following near the VCC pins:
100 nF capacitor (e.g Murata GRM155R61A104K) to filter digital logic noise from clocks and data sources
22 µF capacitor (e.g. Murata GRM31CR60J226K) to supply local DC energy.
Figure 6 shows the complete configuration but the mounting of each single component depends on the
application design.
LISA-C200.
FW75.
CDMA-2X-11004-3
Preliminary
System description
Page 15 of 43
LISA-C200 & FW75-C200 - System Integration Manual
u-blox C200
3.6V
VCC
VCC
VCC
VCC
VCC
C1
C2
LISA-C200
FW75
GND
Figure 6: Suggested schematic design to reduce voltage ripple and noise and to avoid undershoot/ overshoot on voltage drops
Reference
Description
Part Number - Manufacturer
C1
22 µF Capacitor Ceramic 6.3 V 45
GRM31CR60J226K - Murata
C2
100 nF Capacitor Ceramic X7R 0402 10% 16 V
GRM155R61A104KA01 - Murata
Table 6: Suggested components to reduce voltage ripple and noise and to avoid undershoot/ overshoot on voltage drops
CDMA-2X-11004-3
Preliminary
System description
Page 16 of 43
LISA-C200 & FW75-C200 - System Integration Manual
1.4.3 Current consumption profiles
During operation, the current drawn by the LISA-C200 & FW75-C200 modules through the VCC pins can vary by
several orders of magnitude. This ranges from continuous high current drawn in CDMA connected mode, to the
low current consumption during in idle mode.
1.4.3.1
CDMA connected mode
During a CDMA connection, the module can transmit and receive continuously due to the Frequency Division
Duplex (FDD) mode of operation with the Code Division Multiple Access (CDMA). The current consumption
depends again on output RF power, which is always regulated by network commands. These power control
commands are logically divided into a slot of 1.25 ms, thus the rate of power change can reach a maximum rate
of 800 Hz. Since transmission and reception are continuously enabled due to FDD CDMA implemented in the 3G
that differs from the TDMA implemented in the 2G case. In the worst scenario, corresponding to a continuous
transmission and reception at maximum output power (approximately 250 mW or 24 dBm), the current dra wn
by the module at the VCC pins is in the order of continuous 600-700 mA. Even at lowest output RF power
(approximately 0.01 µW or -50 dBm), the current is in the order of less than 100 mA due to module baseband
processing and transceiver activity.
An example of current consumption profile of the data module in CDMA continuous transmission mode is
shown in Figure 7.
Curre nt [mA]
610 mA
700
600
500
Depends on TX pow er
400
Not actual data f or
illustration
300
<100 mA
200
100
1 slot
3G frame
Time
[ms]
Figure 7: VCC current consumption profile versus time during a CDMA connection, with VCC=3.8 V
When a packet data connection is established, the actual current profile depends on the amount of transmitted
packets; there might be some periods of inactivity between allocated slots where current consumption drops
about 100 mA. Alternatively, at higher data rates the transmitted power is likely to increase due to the higher
quality signal required by the network to cope with enhanced data speed.
CDMA-2X-11004-3
Preliminary
System description
Page 17 of 43
LISA-C200 & FW75-C200 - System Integration Manual
1.5
System functions
1.5.1 Module power on
The module power on sequence is initiated in one of these ways:
Rising edge on the VCC pin to a valid voltage for module supply AND if the PWR_ON pin is permanently
low when VCC is applied
Falling edge on the PWR_ON pin (pin must be held low for >150 msec)
Name
Description
Remarks
PWR_ON
Power on input
PWR_ON pin has internal pull up resistor. Recommended to
use open collector or drain configuration to pull down.
Table 7: Power on pin
The PWR_ON pin ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher
protection level could be required if the line is externally accessible on the application board. Higher
protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor
array) on the line connected to this pin.
1.5.1.1
Rising edge on VCC
\When a supply is connected to VCC pins, the module supply supervision circuit controls the subsequent
activation of the power up state machines: the module is switched on when the voltage rises up to the VCC
operating range minimum limit (3.4 V) starting from a voltage value lower than 2.25 V (See LISA-C200 Data
Sheet [1] or the FW75-C200 Data Sheet [2]), provided that the PWR_ON pin is permanently low when VCC
is applied.
1.5.1.2
Falling edge on PWR_ON
The module power on sequence starts when a falling edge is forced on the PWR_ON input pin. After applying a
falling edge, it is suggested to hold a low level on the PWR_ON signal for at least 300 ms to properly switch on
the module.
The electrical characteristics of the PWR_ON input pin are different from the other digital I/O interfaces: the high
and the low logic levels have different operating ranges and the pin is not-tolerant to voltages up to the battery
voltage. The detailed electrical characteristics are described in the LISA-C200 Data Sheet [1] or the FW75-C200
Data Sheet [2].
Once the module has been turned on, PWR_ON pin has no effect. On the other hand it makes no sense to keep
this pin low once the module has been turned on: if the pin is kept low it will draw unnecessary current.
Following are some typical examples of application circuits to turn the module on using the PWR_ON input pin.
The simplest way to turn on the module is to use a push button that shorts the PWR_ON pin to ground.
If the PWR_ON input is connected to an external device (e.g. application processor), it is suggested to use an
open drain output on the external device.
CDMA-2X-11004-3
Preliminary
System description
Page 18 of 43
LISA-C200 & FW75-C200 - System Integration Manual
u-blox C200
Power-on
push button
PWR_ON
ESD
Application
Processor
u-blox C200
Open
Drain
Output
PWR_ON
Figure 8: PWR_ON application circuits using a push button and an open drain output of an application processor
Reference
Description
Remarks
ESD
CT0402S14AHSG - EPCOS
Varistor array for ESD protection
Table 8: Example of pull-up resistor and ESD protection for the PWR_ON application circuits
1.5.1.3 Additional considerations
The module is switched on when the voltage rises up to the VCC operating range: the first time that the module
is used, it is switched on in this way. Then, the proper way to switch off the module is by means of the
AT+CPWROFF command. When the module is in power-off mode, i.e. the AT+CPWROFF command has been
sent and a voltage value within the operating range limits is still provided to the VCC pin, the digital inputoutput pads of the baseband chipset (i.e. all the digital pins of the module) are locked in tri-state (i.e. floating).
The power down tri-state function isolates the module pins from its environment, when no proper operation of
the outputs can be guaranteed.
The module can be switched on from power-off mode by forcing a proper start-up event (i.e. a falling edge on
the PWR_ON pin). After the detection of a start-up event, all the digital pins of the module are held in tri-state
until all the internal LDO voltage regulators are turned on in a defined power-on sequence. Then, as described in
Datasheet the baseband core is still held in reset state for a time interval: the internal reset signal (which is not
available on a module pin) is still low and any signal from the module digital interfaces is held in reset state. The
reset state of all the digital pins is reported in the pin description table of the LISA-C200 Data Sheet [1] or the
FW75-C200 Data Sheet [2]. When the internal signal is released, the configuration of the module interfaces
starts: during this phase any digital pin is set in a proper sequence from the reset state to the default operational
configuration. Finally, the module is fully ready to operate when all interfaces are configured.
The Internal Reset signal is not available on a module pin.
CDMA-2X-11004-3
Preliminary
System description
Page 19 of 43
LISA-C200 & FW75-C200 - System Integration Manual
1.5.2 Module power off
The correct way to switch off LISA-C200 & FW75-C200 modules is by means of +CPWROFF AT command (more
details in u-blox C200 AT Commands Manual [3]): in this way the current parameter settings are saved in the
module’s non-volatile memory and a proper network detach is performed.
An under-voltage shutdown will be done if the VCC supply is removed, but in this case the current parameter
settings are not saved in the module’s non-volatile memory and a proper network detach cannot be performed.
1.5.3 Module reset
The module reset can be performed:
Forcing a low level on the RESET_N input pin, causing an “external” or “hardware” reset (LISA-C200 only)
AT+CFUN command (more details in u-blox C200 AT Commands Manual [3]): in this case an “internal” or
“software” reset is performed, causing an asynchronous reset of the baseband processor
1.6 RF connection
The ANT connector has 50 nominal characteristic impedance and must be connected to the antenna through
a 50
transmission line to allow transmission and reception of radio frequency (RF) signals in the Cell and PCS
operating bands.
Name
Description
Remarks
ANT
FW75
LISA-C200
RF connector
Zo = 50 nominal characteristic impedance.
U.FL connector
Surface Mount pad
Table 9: Antenna connector
The ANT port ESD immunity rating is 500 V (according to IEC 61000-4-2). Higher protection level could
be required if the line is externally accessible on the application board.
Choose an antenna with optimal radiating characteristics for the best electrical performance and overall module
functionality. Focus on minimizing the insertion loss between radiating antenna and the module RF connector.
Overall system performance depends on antenna reception and transmission. See section 2.4 for further details
regarding antenna guidelines.
CDMA-2X-11004-3
Preliminary
System description
Page 20 of 43
LISA-C200 & FW75-C200 - System Integration Manual
1.7 Serial communication
LISA-C200 & FW75-C200 modules provide the following serial communication interfaces where AT command
interface and Packet-Switched Data communication are concurrently available:
One asynchronous serial interface (UART) that provides RS-232 functionality conforming to ITU-T V.24
Recommendation [4], with limited data rate.
One full-speed USB 2.0 compliant interface, with maximum data rate of 12 Mb/s.
Only one interface is active. Default is USB, if no USB is detected then it is assumed that the UART interface
is desired.
LISA-C200 & FW75-C200 modules are designed to operate as a CDMA wireless modem, which represents the
data circuit-terminating equipment (DCE) as described by the ITU-T V.24 Recommendation [4]. A customer
application processor connected to the module through one of the interfaces represents the data terminal
equipment (DTE).
All the interfaces listed above are controlled and operated with:
Sprint required AT Commands
Verizon required AT Commands
AT commands according to 3GPP TS 27.010 [7]
AT commands according to 3GPP TS 27.005 [6]
AT commands according to 3GPP TS 27.010
u-blox AT commands
For the complete list of supported AT commands and their syntax refer to the u-blox C200 AT
Commands Manual [3].
The USB interface, using all the lines provided (VUSB_DET, USB_D+ and USB_D-), can be used for firmware
upgrade:
To directly enable PC (or similar) connection to the module for firmware upgrade, provide direct access
on the application board to the VUSB_DET, USB_D+ and USB_D- lines of the module . Also provide
access to the PWR_ON & HW_SHUTDOWN pins, or enable the DC supply connected to the VCC pin to
start the module firmware upgrade The following sub-chapters describe serial interface configuration
and provide a detailed description of each interface for the application circuits.
1.7.1 Serial interfaces configuration
UART and USB serial interfaces are available as AT command interface and for Packet-Switched Data
communication. The serial interfaces are configured as described in Table 10 (for information about further
settings, please refer to the u-blox C200 AT Commands Manual [3]).
Note : The UART is 5 wire implementation therefore DTR, DSR and DCD functions are not available.
CDMA-2X-11004-3
Preliminary
System description
Page 21 of 43
LISA-C200 & FW75-C200 - System Integration Manual
Interface
AT Settings
Comments
UART interface
Enabled
Multiplexing mode can be enabled by AT+CMUX command providing following channels:
Channel 0: control channel
Channel 1: AT commands
Channel 2: data connection
AT+IPR=115200
Baud rate: 115200 b/s
AT+ICF=0,0
Frame format: 8 bits, no parity, 1 stop bit
USB interface
Enabled
Table 10: Default serial interfaces configuration
1.7.2 Asynchronous serial interface (UART)
The UART interface is a 5-wire unbalanced asynchronous serial interface that provides AT commands interface
and PSD data communication.
UART interface provides RS-232 functionality conforming to the ITU-T V.24 Recommendation (more details
available in ITU Recommendation [4]), with CMOS compatible signal levels: 0 V for low data bit or ON state, and
2.8 V for high data bit or OFF state. One external voltage translators (e.g. Maxim MAX13234E) could be used to
provide RS-232 (5 lines) compatible signal levels. This chip translates the voltage levels from 1.8 V (module side)
to the RS-232 standard. For detailed electrical characteristics refer to LISA-C200 Data Sheet [1] or the FW75C200 Data Sheet [2].
FW75-C200 logic levels are 2.8 V interface. LISA-C200 logic levels are 1.8 V interface.
The LISA-C200 & FW75-C200 modules are designed to operate as a CDMA wireless modem, which represents
the data circuit-terminating equipment (DCE) as described by the ITU-T V.24 Recommendation [4]. A customer
application processor connected to the module through the UART interface represents the data terminal
equipment (DTE).
The signal names of the LISA-C200 & FW75-C200 modules UART interface conform to the ITU-T V.24
Recommendation [4].
UART interfaces include the following lines:
Name
Description
Remarks
RI
Ring Indicator
Module output
RTS
Ready to send
Module hardware flow control input
Circuit 105 (Request to send) in ITU-T V.24
FW75 - Internal active pull-up to V_INT (2.8 V) interface.
LISA-C200- Internal active pull-up to V_INT (1.8 V) interface.
CTS
Clear to send
Module hardware flow control output
Circuit 106 (Ready for sending) in ITU-T V.24
FW75-C200 - Internal active pull-up to V_INT (2.8 V) interface.
LISA-C200- Internal active pull-up to V_INT (1.8 V) interface.
TxD
Transmitted data
Module data input
Circuit 103 (Transmitted data) in ITU-T V.24
Internal active pull-up to V_INT (2.8 V) enabled.
FW75-C200- Internal active pull-up to V_INT (2.8 V) interface.
LISA-C200- Internal active pull-up to V_INT (1.8 V) interface.
RxD
Received data
Module data output
Circuit 104 (Received data) in ITU-T V.24
FW75-C200- Internal active pull-up to V_INT (2.8 V) interface.
LISA-C200- Internal active pull-up to V_INT (1.8 V) interface.
GND
Ground
Table 11: UART interface signals
CDMA-2X-11004-3
Preliminary
System description
Page 22 of 43
LISA-C200 & FW75-C200 - System Integration Manual
The UART interface pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F).
Higher protection level could be required if the lines are externally accessible on the application board.
Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG
varistor array) on the lines connected to these pins.
UART application circuits
Providing the TxD, RxD, RI, RTS and CTS lines only (not using the complete V.24 link)
Modem DSR, DCD and DTR lines is not available in the application, the application circuit described in Figure 9
must be implemented:
u-blox C200
(DCE)
Application Processor
(DTE)
TxD
RxD
RTS
CTS
0Ω
TP
0Ω
TP
0Ω
TP
0Ω
TP
TXD
RXD
RTS
CTS
DTR
DSR
RI
RI
DCD
GND
GND
Figure 9: UART interface application circuit with partial V.24 link (5-wire) in the DTE/DCE serial communication
Additional considerations
If the module USB interface is connected to the application processor, testpoints can be added on the
lines to accommodate the access and a 0 Ω series resistor must be mounted on each line to detach the
module pin from any other connected device. Otherwise, if the USB interface is not connected to the
application processor, it is highly recommended to provide direct access to VUSB_DET, USB_D+,
USB_D- lines for execution of firmware upgrade over USB and for debug purpose. In both cases,
provide as well access to RESET_N pin, or to the PWR_ON pin, or enable the DC supply connected to
the VCC pin to start the module firmware upgrade.
CDMA-2X-11004-3
Preliminary
System description
Page 23 of 43
LISA-C200 & FW75-C200 - System Integration Manual
1.7.3 USB interface
LISA-C200 & FW75-C200 modules provide a full-speed USB interface at 12 Mb/s compliant with the Universal
Serial Bus Revision 2.0 specification [9]. It acts as a USB device and can be connected to any USB host such as a
PC or other Application Processor.
The USB-device shall look for all upper-SW-layers like any other serial device. This means that LISA-C200 &
FW75-C200 modules emulate all serial control logical lines.
If the logical DTR line isn't enabled by the USB host, the module doesn’t answer to AT commands by the
USB interface.
Name
Description
Remarks
VUSB_DET
USB detect input
Apply 5 V typical to enable USB
USB_D+
USB Data Line D+
90 Ω nominal differential impedance.
Pull-up or pull-down resistors and external series resistors as
required by the USB 2.0 high-speed specification [9] are part
of the USB pad driver and need not be provided externally.
USB_D-
USB Data Line D-
90 Ω nominal differential impedance.
Pull-up or pull-down resistors and external series resistors as
required by the USB 2.0 high-speed specification [9] are part
of the USB pad driver and need not be provided externally.
Table 12: USB pins
The USB interface pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F).
Higher protection level could be required if the lines are externally accessible on the application board.
Higher protection level can be achieved by mounting a very low capacitance (i.e. less or equal to 1 pF)
ESD protection (e.g. Tyco Electronics PESD0402-140 ESD protection device) on the lines connected to
these pins.
LISA-C200 & FW75-C200 module identifies itself by its VID (Vendor ID) and PID (Product ID) combination,
included in the USB device descriptor. VID and PID of LISA-C200 & FW75-C200 modules are the following:
VID = 0x1546 PID = 0x1121
1.7.3.1
USB application circuit
Since the module acts as a USB device, the USB supply (5.0 V typ.) must be provided to VUSB_DET by the
connected USB host. The USB interface is enabled only when a valid voltage as USB supply is detected by the
VUSB_DET input. Neither the USB interface, nor the whole module is supplied by the VUSB_DET input: the
VUSB_DET senses the USB supply voltage and absorbs few microamperes.
The USB_D+ and USB_D- lines carry the USB serial data and signaling. The lines are used in single ended mode
for relatively low speed signaling handshake, as well as in differential mode for fast signaling and data transfer.
USB pull-up or pull-down resistors on pins USB_D+ and USB_D- as required by the Universal Serial Bus Revision
2.0 specification [9] are part of the USB pad driver and do not need to be externally provided.
External series resistors on pins USB_D+ and USB_D- as required by the Universal Serial Bus Revision 2.0
specification [9] are also integrated: characteristic impedance of USB_D+ and USB_D- lines is specified by the
USB standard. The most important parameter is the differential characteristic impedance applicable for
odd-mode electromagnetic field, which should be as close as possible to 90
differential: signal integrity may
be degraded if the PCB layout is not optimal, especially when the USB signaling lines are very long.
CDMA-2X-11004-3
Preliminary
System description
Page 24 of 43
LISA-C200 & FW75-C200 - System Integration Manual
USB DEVICE
CONNECTOR
u‐blox C200
VBUS
VUSB_DET
D+
USB_D+
D-
USB_D-
D1
D2
D3
C1
GND
GND
Figure 10: USB Interface application circuit
Reference
Description
Part Number - Manufacturer
D1, D2, D3
Very Low Capacitance ESD Protection
PESD0402-140 - Tyco Electronics
C2
100 nF Capacitor Ceramic X7R 0402 10% 16 V
GRM155R61A104KA01 - Murata
Table 13: Component for USB application circuit
If the USB interface is not connected to the application processor, it is highly recommended to provide
direct access to the VUSB_DET, USB_D+, USB_D- lines for execution of firmware upgrade over USB
and for debug purpose: testpoints can be added on the lines to accommodate the access. Provide access
to RESET_N pin, or to the PWR_ON pin, or enable the DC supply connected to the VCC pin to start the
module firmware upgrade
If the USB interface is not used, the USB_D+, USB_D- and VUSB_DET pins can be left unconnected,
but it is highly recommended to provide direct access to the lines for execution of firmware upgrade and
for debug purpose.
1.7.4 MUX Protocol (3GPP 27.010)
LISA-C200 & FW75-C200 modules have a software layer with MUX functionality, 3GPP TS 27.010 Multiplexer
Protocol [7], available on the UART physical link. The USB interface doesn’t support the multiplexer protocol.
This is a data link protocol (layer 2 of OSI model) which uses HDLC-like framing and operates between the
module (DCE) and the application processor (DTE) and allows a number of simultaneous sessions over the UART:
the user can concurrently use AT command interface on one MUX channel and Packet-Switched Data
communication on another MUX channel.. Each session consists of a stream of bytes transferring various kinds
of data such as SMS, PSD, AT commands in general. This permits, for example, SMS to be transferred to the DTE
when a data connection is in progress.
The following virtual channels are defined:
Channel 0: control channel
Channel 1: AT commands
Channel 2: data connection
1.8
Reserved pins (RSVD)
LISA-C200 & FW75-C200 modules have pins reserved for future use. All the RSVD pins/pads must be left
unconnected on the application board.
CDMA-2X-11004-3
Preliminary
System description
Page 25 of 43
LISA-C200 & FW75-C200 - System Integration Manual
1.9
Schematic for LISA-C200 and FW75-C200 modules integration
Figure 11 shows the integration of a LISA-C200 / FW75-C200 modules into an application board, using all the
module interfaces.
FW75-C200
3V6
Antenna Connection
FW75 – U.FL Connector
LISA-C200 SMT PAD
ANT
VCC
VCC
SIM Card Holder
VCC
VCC
22µF 100nF
VCC
1k
V_INT
SW1
GPIO5
SW2
CCVCC (C1)
VSIM
CCVPP (C6)
GND
CCIO (C7)
SIM_IO
Application
Processor
SIM_CLK
CCCLK (C3)
SIM_RST
CCRST (C2)
GND (C5)
PWR_ON
Open
Drain
Output
470k
47pF 47pF 47pF 47pF 100nF
ESD ESD ESD ESD ESD ESD
Ferrite Bead
Open
Drain
Output
HW_SHUTDOWN (FW75-C200)
RESET_N (LISA-C200)
47pF
DTE FW75 2.8V LISA –
1.8V
GPIO2
TXD
RXD
RTS
CTS
0Ω
TP
0Ω
TP
0Ω
TP
0Ω
TP
GPIO3
TXD
GPIO4
RXD
RTS
CTS
LISA‐C200 only
DTR
DTR
DSR
DSR
RI
RI
GND
GND
USB 2.0 Host
VBUS
VUSB_DET
D+
USB_D+
D-
USB_D100nF
GND
GND
3V8
Network
Indicator
GPIO1
Figure 11: Example schematic integrating FW75-C200/LISA-C200 module in an application board, using all the interfaces
UART FW75-C200 and LISA-C200 pins use different voltage levels (1.8V LISA-C200, 2.8V FW75-C200)
CDMA-2X-11004-3
Preliminary
System description
Page 26 of 43
LISA-C200 & FW75-C200 - System Integration Manual
1.10 Approvals
LISA-C200 & FW75-C200 modules have been or will be approved under the following schemes:
CDG1
CDMA Development Group 1 Radio Conformance Testing
CDG2
CDMA Development Group 2 Inter-operability
Sprint
Carrier Certification
Verizon Carrier Certification
FCC
(Federal Communications Commission)
IC
(Industry Canada)
1.10.1 Declaration of Conformity for products marked with the FCC logo - United
States only
Radiofrequency radiation exposure Information: this equipment complies with FCC radiation
exposure limits prescribed for an uncontrolled environment. This equipment should be installed
and operated with a minimum distance of 20 cm between the radiator and your body.
1.10.2 Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are not
expressly approved by u-blox could void the user's authority to operate the equipment.
Manufacturers of mobile or fixed devices incorporating the LISA-C200 & FW75-C200 modules
are authorized to use the FCC Grants and Industry Canada Certificates of the LISA-C200 & FW75C200 modules for their own final products according to the conditions referenced in the
certificates.
The FCC Label shall in the above case be visible from the outside, or the host device shall bear a
second label stating:
for FW75: “Contains FCC ID: XU9-FW75”
And for LISA C200 “Contains FCC ID: R5Q-LISAC200A”
The IC Label shall in the above case be visible from the outside, or the host device shall bear a
second label stating
for FW75: “Contains IC: 8694A-FW75”
And for LISA C200 “Contains IC: 8595B-LISAC200A”
Canada, Industry Canada (IC) Notices
Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
Canada, avis d'Industrie Canada (IC)
Les changements ou modifications n'ont pas était expressément approuvés par la partie
responsable de la conformité, ils pourraient annulée l'autorité de l'utilisateur pour exploiter
l'équipement.
CDMA-2X-11004-3
Preliminary
System description
Page 27 of 43
LISA-C200 & FW75-C200 - System Integration Manual
2 Design-In
2.1 Design-in checklist
2.1.1 Schematic checklist
The following are the most important points for a simple schematic check:


DC supply must provide a nominal voltage at VCC pin above the minimum operating range limit.








VCC supply should be clean, with very low ripple/noise: suggested passive filtering parts can be inserted.




Provide appropriate access to USB interface and/or to UART RxD, TxD, CTS, RTS lines for debugging.



Insert the suggested passive filtering parts on each used analog audio line.

Check 50
nominal characteristic impedance of the RF transmission line connected to ANT coax
connector or Printed Circuit Board 50 transmission line impedance for LISA-C200







Follow the recommendations of the antenna producer for correct antenna installation and deployment.
DC supply must be capable of supporting 1.2 A, providing a voltage at VCC pin above the minimum
operating range limit and with a maximum 250 mV voltage drop from the nominal value.
Connect only one DC supply to VCC: different DC supply systems are mutually exclusive.
Don’t apply loads which might exceed the limit for maximum available current from V_INT supply.
Check that voltage level of any connected pin does not exceed the relative operating range.
Capacitance and series resistance must be limited on each SIM signal to match the SIM specifications.
Insert the suggested low capacitance ESD protection and passive filtering parts on each SIM signal.
Check UART signals direction, since the signal names follow the ITU-T V.24 Recommendation [4].
Provide appropriate access to USB interface and/or to UART RxD, TxD lines and access to PWR_ON
and/or HW_SHUTDOWN lines on the application board in order to flash/upgrade the module firmware.
Add a proper pull-up resistor to a proper supply on each DDC (I2C) interface line, if the interface is used.
Capacitance and series resistance must be limited on each line of the DDC interface.
Use transistors with at least an integrated resistor in the base pin or otherwise put a 10 kΩ resistor on
the board in series to the GPIO when those are used to drive LEDs.
Provide proper precautions for ESD immunity as required on the application board.
All unused pins can be left floating on the application board Layout checklist
The following are the most important points for a simple layout check:
Ensure no coupling occurs with other noisy or sensitive signals (primarily SIM signals).
VCC line should be wide and short.
Ensure proper grounding.
Consider “No-routing” areas for the Data Module footprint.
Optimize placement for minimum length of RF line and closer path from DC source for VCC.
Design USB_D+ / USB_D- connection as 90
differential pair.
2.1.2 Antenna checklist

Antenna should have 50 impedance, V.S.W.R less then 3:1, recommended 2:1 on operating bands in
deployment geographical area.

Follow the recommendations of the antenna producer for correct antenna installation and deployment
(PCB layout and matching circuitry).
CDMA-2X-11004-3
Preliminary
Design-In
Page 28 of 43
LISA-C200 & FW75-C200 - System Integration Manual
2.2 Connectors (FW75)
The following design information is to aid the design for proper selection of mating connectors and antennas.
2.2.1 FW75-C200 modem connector
Manufacturer
Molex
Series Name
SlimStack
Part No.
52991-0808
Specification
PS-54-167-002
Description
Receptacle 80 pins,
0.50mm pitch, 4mm
stacking height
Remarks
Website : www.molex.com
Drawing: 529910708_sd.pdf (mechanical,
land pattern and reel specifications)
Data sheet :
05339160208_PCB_RECEPTABLES.pdf
Table 14: FW75-C200 modem connector
Figure 12: FW75-C200 modem connector
2.2.2 FW75-C200 Board to Board host connector
Manufacturer
Molex
Series Name
SlimStack
Part No.
53916-0808
Specification
PS-54-167-002
Description
Header 80 pins,
0.50mm pitch, 4mm
stacking height
Remarks
Website : www.molex.com
Drawing: 539160208_sd.pdf (mechanical,
land pattern and reel specifications)
Data sheet :
05339160208_PCB_HEADERS.pdf
Table 15: FW75-C200 host mate connector
Figure 13: FW75-C200 host mate connector
CDMA-2X-11004-3
Preliminary
Design-In
Page 29 of 43
LISA-C200 & FW75-C200 - System Integration Manual
2.2.3 FW75-C200 RF antenna connector
Manufacturer
Molex
Series Name
73412
Part No.
73412-0110
Specification
PS-73598-02
Description
Microcoaxial RF,
50 Ω, PCB Vertical
Jack Receptacle,
SMT, 1.25 mm
(0.049”) Mounted
Height
Remarks
Website : www.molex.com
Drawing: 734120110_sd.pdf (mechanical,
land pattern and reel specifications)
Data sheet:
0734120110_RF_COAX_CONNECTORS.pdf
Table 16: FW75-C200 antenna connector
Figure 14: FW75-C200 antenna connector
CDMA-2X-11004-3
Preliminary
Design-In
Page 30 of 43
LISA-C200 & FW75-C200 - System Integration Manual
2.3 Design Guidelines
The following design guidelines must be met for optimal integration of LISA-C200 module on the final
application board.
2.3.1 Layout guidelines per pin function
This section groups the u-blox C200 module pins by signal function and provides a ranking of importance in
layout design. See 1: FW75-C200
: LISA-C200
Table 17 for a list of pins ranked by their importance in layout design. See the LISA-C200 Data Sheet [1] or the
FW75 Data Sheet [2] for the complete pin lists.
Rank
Function
st
RF Connector
nd
Main DC Supply
rd
USB Signals
th
Ground
th
Sensitive Pin :
Power On
HW_SHUTDOWN
th
Pin(s)
ANT
VCC
USB_D+
USB_DGND
Remarks
Very Important
Design for 50
Very Important
VCC line should be wide and short. Route away
from sensitive analog signals.
characteristic impedance.
Very Important
Route USB_D+ and USB_D- as differential lines:
design for 90 differential impedance.
Careful Layout
Provide proper grounding.
Careful Layout
Avoid coupling with noisy signals.
Common
Practice
Follow common practice rules for digital pin
routing.
PWR_ON
HW_SHUTDOWN
Digital pins and
supplies:
SIM Card Interface
VSIM, SIM_CLK,
SIM_IO, SIM_RST
UART
External Reset
TXD, RXD, CTS, RTS, RI
HW_SHUTDOWN
RESET_N
General Purpose I/O
Layout
USB detection
GPIO1, GPIO2, GPIO3,
GPIO4, GPIO5
VUSB_DET
Supply for Interfaces
V_INT
: FW75-C200
: LISA-C200
Table 17: Pin list in order of decreasing importance for layout design
CDMA-2X-11004-3
Preliminary
Design-In
Page 31 of 43
LISA-C200 & FW75-C200 - System Integration Manual
2.4 Antenna guidelines
Antenna characteristics are essential for good functionality of the module. Antenna radiating performance has
direct impact on the reliability of connections over the Air Interface. A bad termination of ANT can result in poor
performance of the module.
The following parameters should be checked:
Item
Recommendations
Impedance
50 Ω nominal characteristic impedance
Frequency Range
Depends on the Mobile Network used.
LISA-C200:
- Cell Band B0: 824..894 MHz
- PCS Band B1 B2: 1850..1990 MHz
Input Power
V.S.W.R
>2 W peak
<2:1 recommended, <3:1 acceptable
Return Loss
S11<-10 dB recommended, S11<-6 dB acceptable
Gain
<3 dBi
Table 18: General recommendation for CDMA antenna
To preserve the original u-blox FCC ID, antenna gain shall remain below 3 dBi.
CDMA antennas are typically available as:
Linear monopole: typical for fixed applications. The antenna extends mostly as a linear element with a
dimension comparable to lambda/4 of the lowest frequency of the operating band. Magnetic base may be
available. Cable or direct RF connectors are common options. The integration normally requires the
fulfillment of some minimum guidelines suggested by antenna manufacturer
Patch-like antenna: better suited for integration in compact designs (e.g. mobile phone). These are mostly
custom designs where the exact definition of the PCB and product mechanical design is fundamental for
tuning of antenna characteristics
For integration observe these recommendations:
Ensure 50 Ω antenna termination by minimizing the V.S.W.R. or return loss, as this will optimize the
electrical performance of the module. See section 2.4.1
Select antenna with best radiating performance. See section 2.4.2
If a cable is used to connect the antenna radiating element to application board, select a short cable with
minimum insertion loss. The higher the additional insertion loss due to low quality or long cable, the lower
the connectivity
Follow the recommendations of the antenna manufacturer for correct installation and deployment
Do not include antenna within closed metal case
Do not place antenna in close vicinity to end user since the emitted radiation in human tissue is limited by
S.A.R. regulatory requirements
Do not use directivity antenna since the electromagnetic field radiation intensity is limited in some countries
Take care of interaction between co-located RF systems since the RF transmitted power may interact or
disturb the performance of companion systems
Place antenna far from sensitive analog systems or employ countermeasures to reduce electromagnetic
compatibility issues that may arise
CDMA-2X-11004-3
Preliminary
Design-In
Page 32 of 43
LISA-C200 & FW75-C200 - System Integration Manual
2.4.1 Antenna termination
The LISA-C200 & FW75-C200 modules are designed to work on a 50
load. However, real antennas have no
perfect 50 load on all the supported frequency bands. Therefore, to reduce as much as possible performance
degradation due to antenna mismatch, the following requirements should be met:
Measure the antenna termination with a network analyzer: connect the antenna through a coaxial cable to the
measurement device, the |S11| indicates which portion of the power is delivered to antenna and which portion is
reflected by the antenna back to the module output.
A good antenna should have an |S11| below -10 dB over the entire frequency band. Due to miniaturization,
mechanical constraints and other design issues, this value will not be achieved. An |S 11| value of about -6 dB – (in
the worst case) - is acceptable.
Figure 15 shows an example of this measurement:
Figure 15: |S11| sample measurement of a penta-band antenna that covers in a small form factor the 4 bands (850 MHz, 900 MHz,
1800 MHz and 1900 MHz)
Figure 16 shows comparable measurements performed on a wideband antenna. The termination is better, but
the size of the antenna is considerably larger.
Figure 16: |S11| sample measurement of a wideband antenna
CDMA-2X-11004-3
Preliminary
Design-In
Page 33 of 43
LISA-C200 & FW75-C200 - System Integration Manual
2.4.2 Antenna radiation
An indication of the antenna’s radiated power can be approximated by measuring the |S 21| from a target antenna
to the measurement antenna, using a network analyzer with a wideband antenna. Measurements should be
done at a fixed distance and orientation, and results compared to measurements performed on a known good
antenna. Figure 17 through Figure 18 show measurement results. A wideband log periodic-like antenna was
used, and the comparison was done with a half lambda dipole tuned at 900 MHz frequency. The measurements
show both the |S11| and |S21| for the penta-band internal antenna and for the wideband antenna.
Figure 17: |S11| and |S21| comparison between a 900 MHz tuned half wavelength dipole (green/purple) and a penta-band internal
antenna (yellow/cyan)
The half lambda dipole tuned at 900 MHz is known and has good radiation performance (both for gain and
directivity). Then, by comparing the |S 21| measurement with antenna under investigation for the frequency where
the half dipole is tuned (e.g. marker 3 in Figure 17) it is possible to make a judgment on the antenna under test:
if the performance is similar then the target antenna is good.
Figure 18: |S11| and |S21| comparison between a 900 MHz tuned half wavelength dipole (green/purple) and a wideband
commercial antenna (yellow/cyan)
Instead if |S21| values for the tuned dipole are much better than the antenna under evaluation (like for marker 1/2
area of Figure 18, where dipole is 5 dB better), then it can be argued that the radiation of the target antenna
(the wideband dipole in this case) is considerably less.
The same procedure should be repeated on other bands with half wavelength dipole re-tuned to the band under
investigation.
CDMA-2X-11004-3
Preliminary
Design-In
Page 34 of 43
LISA-C200 & FW75-C200 - System Integration Manual
For good antenna radiation performance, antenna dimensions should be comparable to a quarter of the
wavelength. Different antenna types can be used for the module, many of them (e.g. patch antennas,
monopole) are based on a resonating element that works in combination with a ground plane. The
ground plane, ideally infinite, can be reduced down to a minimum size that must be similar to one
quarter of the wavelength of the minimum frequency that has to be radiated (transmitted/received).
Numerical sample: frequency = 1 GHz  wavelength = 30 cm  minimum ground plane (or antenna
size) = 7.5 cm. Below this size, the antenna efficiency is reduced.
2.5 ESD immunity test precautions
The immunity of the device (i.e. the application board where LISA-C200 & FW75-C200 module is mounted)
Electrostatic Discharge must be certified in compliance to the testing requirements standard [12], and the
requirements for radio and digital cellular radio telecommunications system equipment standards [12] and [14].
The ESD test is performed at the enclosure port referred to as the physical boundary through which the EM field
radiates. If the device implements an integral antenna, the enclosure port is seen as all insulating and conductive
surfaces housing the device. If the device implements a removable antenna, the antenna port can be separated
from the enclosure port. The antenna port comprises the antenna element and its interconnecting cable
surfaces.
The applicability of the ESD test depends on the device classification, as well the test on other ports or on
interconnecting cables to auxiliary equipments depends to the device accessible interfaces and manufacturer
requirements.
Contact discharges are performed at conductive surfaces whereas air discharges are performed on insulating
surfaces. Indirect contact discharges are performed on the measurement setup horizontal and vertical coupling
planes.
Implement the following precautions to satisfy ESD immunity test requirements performed at the device
enclosure in compliance to the category level and shown in the following table.
Application
Category
Immunity Level
All exposed surfaces of the radio equipment and ancillary equipment
in a representative configuration
Contact Discharge
4 kV
Air Discharge
8 kV
Table 19: Electromagnetic Compatibility (EMC) ESD immunity requirement, standards “EN 61000-4-2, EN 301 489-1 V1.8.1, EN
301 489-7 V1.3.1”
Although EMC certification (including ESD immunity testing) must be performed in the final application of the
radio equipment EUT, results are provided for LISA modules performing the test with a representative
configuration to show that requirements can be met.
Since an external antenna is used, the antenna port can be separated from the enclosure port. The reference
application is not enclosed in a box so the enclosure port is not indentified with physical surfaces. Therefore,
some test cases cannot be applied. Only the antenna port is identified as accessible for direct ESD exposure.
The reference application implements all precautions described in the sections below. ESD immunity test results
and applicability are reported in Table 20 according to test requirements [12], [12] and [14].
CDMA-2X-11004-3
Preliminary
Design-In
Page 35 of 43
LISA-C200 & FW75-C200 - System Integration Manual
Category
Application
Immunity Level
Contact Discharge to coupling planes (indirect contact discharge)
Enclosure
+2 kV / -2 kV
+4 kV / -4 kV
Contact Discharges to conducted surfaces (direct contact discharge)
Enclosure port
Not Applicable
Contact Discharges to conducted surfaces (direct contact discharge)
Antenna port
Not Applicable6
(only antenna with completely
insulating surface can be used)
Air Discharge at insulating surfaces
Enclosure port
Not Applicable
Air Discharge at insulating surfaces
Antenna port
+2 kV / -2 kV
(only antenna with completely
insulating surface can be used)
+4 kV / -4 kV
+8 kV / -8 kV
Table 20: Enclosure ESD immunity level result, standards “EN 61000-4-2, EN 301 489-1 V1.8.1, EN 301 489-7 V1.3.1” for LISA
application reference design.
2.5.1 General precautions
The following module interfaces can have a critical influence in ESD immunity testing, depending on the
application board handling. The following precautions are suggested:
HW_SHUTDOWN pin (FW75-C200 only)
Sensitive interface is the reset line (HW_SHUTDOWN pin):
A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470JA01) have to be mounted on the line termination
connected to the HW_SHUTDOWN pin to avoid a module reset caused by an electrostatic discharge
applied to the application board enclosure
A series ferrite bead (e.g. Murata BLM15HD182SN1) must be added on the line connected to the
HW_SHUTDOWN pin to avoid a module reset caused by an electrostatic discharge applied to the
application board enclosure
It is recommended to keep the connection line to HW_SHUTDOWN as short as possible
Reset_N pin (LISA-C200 only)
Sensitive interface is the reset line (Reset_N pin):
A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470JA01) have to be mounted on the line termination
connected to the Reset_N pin to avoid a module reset caused by an electrostatic discharge applied to the
application board enclosure
A series ferrite bead (e.g. Murata BLM15HD182SN1) must be added on the line connected to the Reset_N
pin to avoid a module reset caused by an electrostatic discharge applied to the application board enclosure
It is recommended to keep the connection line to Reset_N as short as possible
LISA mounted on application design:
Not Applicability -> EUT with insulating enclosure surface, EUT without enclosure surface
Applicability -> EUT with conductive enclosure surface
LISA mounted on application design:
Not Applicability -> Antenna with insulating surface
Applicability -> Antenna with conductive surface
LISA mounted on application design:
Applicability -> EUT with insulating enclosure surface
Not Applicability -> EUT with conductive enclosure surface, EUT without enclosure surface
CDMA-2X-11004-3
Preliminary
Design-In
Page 36 of 43
LISA-C200 & FW75-C200 - System Integration Manual
u-blox C200
Reset
push button
FB1
HW_SHUTDOWN
ESD
C1
Application
Processor
u-blox C200
Open
Drain
Output
FB2
HW_SHUTDOWN
C2
Figure 19: HW_SHUTDOWN application circuits for ESD immunity test
Reference
Description
Remarks
ESD
Varistor for ESD protection.
CT0402S14AHSG - EPCOS
C1, C2
47 pF Capacitor Ceramic C0G 0402 5% 50 V
GRM1555C1H470JA01 - Murata
FB1, FB2
Chip Ferrite Bead for Noise/EMI Suppression
BLM15HD182SN1 - Murata
Rint
10 kΩ Resistor 0402 5% 0.1 W
Internal pull-up resistor
Table 21: Example of components as ESD immunity test precautions for the HW_SHUTDOWN line
SIM interface
Sensitive interface is the SIM interface (VSIM pin, SIM_RST pin, SIM_IO pin, SIM_CLK pin):
A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470J) have to be mounted on the lines connected to
VSIM, SIM_RST, SIM_IO and SIM_CLK to assure SIM interface functionality when an electrostatic discharge
is applied to the application board enclosure
It is suggested to use as short as possible connection lines at SIM pins
SIM card interface is hardware ready but not supported by the current software
2.5.2 Antenna interface precautions
The antenna interface ANT can have a critical influence on the ESD immunity test depending on the application
board handling. Antenna precaution suggestions are provided:
If the device implements an embedded antenna and the device insulating enclosure avoids air discharge up
to +8 kV / -8 kV to the antenna interface, no further precautions to ESD immunity test should be needed
If the device implements an external antenna and the antenna and its connecting cable are provided with a
completely insulating enclosure to avoid air discharge up to +8 kV / -8 kV to the whole antenna and cable
surfaces, no further precautions to ESD immunity test should be needed
CDMA-2X-11004-3
Preliminary
Design-In
Page 37 of 43
LISA-C200 & FW75-C200 - System Integration Manual
If the device implements an external antenna and the antenna or its connecting cable are not provided with
completely insulating enclosure to avoid air discharge up to +8 kV / -8 kV to the whole antenna and cable
surfaces, the following precautions to ESD immunity test should be implemented on the application board
A higher protection level is required at the ANT port if the line is externally accessible on the application board.
ESD immunity test requires protection up to +4 kV / -4 kV for direct Contact Discharge and up to +8 kV / -8 kV
for Air Discharge applied to the antenna port.
2.5.3 Module interfaces precautions
All the module pins that are externally accessible should be included in the ESD immunity test since they are
considered to be a port as defined in [12]. Depending on applicability, and in order to satisfy ESD immunity test
requirements and ESD category level, pins connected to the port should be protected up to +4 kV / -4 kV for
direct Contact Discharge, and up to +8 kV / -8 kV for Air Discharge applied to the enclosure surface.
The maximum ESD sensitivity rating of all the pins of the module, except the ANT pin, is 1 kV (Human Body
Model according to JESD22-A114F). A higher protection level can be achieved by mounting an ESD protection
(e.g. EPCOS CA05P4S14THSG varistor array or CT0402S14AHSG).
For the USB interface a very low capacitance (i.e. less or equal to 1 pF) ESD protection (e.g. Tyco Electronics
PESD0402-140 ESD protection device) can be mounted on the lines connected to USB_D+ and USB_D- pins.
For the SIM interface a low capacitance (i.e. less than 10 pF) ESD protection (e.g. Infineon ESD8V0L2B-03L or
AVX USB0002) must be placed near the SIM card holder on each line (VSIM, SIM_IO, SIM_CLK, SIM_RST).
CDMA-2X-11004-3
Preliminary
Design-In
Page 38 of 43
LISA-C200 & FW75-C200 - System Integration Manual
3 Features description
3.1 Firmware (upgrade) Over The Air (FOTA
LISA-C200 & FW75-C200 modules will support this feature. Sprint Carrier requirement.
Not supported nor required for Verizon Carrier.
3.2 UDP/IP
LISA-C200 & FW75-C200 modules will support this feature in the upcoming FW version.
3.3 HTTP
LISA-C200 & FW75-C200 modules will support this feature in the upcoming FW version.
CDMA-2X-11004-3
Preliminary
Features description
Page 39 of 43
LISA-C200 & FW75-C200 - System Integration Manual
Appendix
A Glossary
ADC
Analog to Digital Converter
AP
Application Processor
AT
AT Command Interpreter Software Subsystem, or attention
CBCH
Cell Broadcast Channel
CS
Coding Scheme
CSD
Circuit Switched Data
CTS
Clear To Send
DC
Direct Current
DCD
Data Carrier Detect
DCE
Data Communication Equipment
DCS
Digital Cellular System
DDC
Display Data Channel
DSP
Digital Signal Processing
DSR
Data Set Ready
DTE
Data Terminal Equipment
DTM
Dual Transfer Mode
DTR
Data Terminal Ready
EBU
External Bus Interface Unit
CDMA
CODE Division Multiple Access
FDD
Frequency Division Duplex
FEM
Front End Module
FOAT
Firmware Over AT commands
FTP
File Transfer Protocol
FTPS
FTP Secure
GND
Ground
GPIO
General Purpose Input Output
GPS
Global Positioning System
HF
Hands-free
HTTP
HyperText Transfer Protocol
HTTPS
Hypertext Transfer Protocol over Secure Socket Layer
HW
Hardware
I/Q
IC
In phase and Quadrature
Inter-Integrated Circuit
IS
Inter IC Sound
IP
Internet Protocol
IPC
Inter Processor Communication
LNA
Low Noise Amplifier
MCS
Modulation Coding Scheme
NOM
Network Operating Mode
CDMA-2X-11004-3
Preliminary
Appendix
Page 40 of 43
LISA-C200 & FW75-C200 - System Integration Manual
PA
Power Amplifier
PBCCH
Packet Broadcast Control Channel
PCM
Pulse Code Modulation
PCS
Personal Communications Service
PFM
Pulse Frequency Modulation
PMU
Power Management Unit
RF
Radio Frequency
RI
Ring Indicator
RTC
Real Time Clock
RTS
Request To Send
RXD
RX Data
SAW
Surface Acoustic Wave
SIM
Subscriber Identification Module
SMS
Short Message Service
SMTP
Simple Mail Transfer Protocol
SRAM
Static RAM
TCP
TDMA
Transmission Control Protocol
Time Division Multiple Access
TXD
TX Data
UART
Universal Asynchronous Receiver-Transmitter
UDP
User Datagram Protocol
USB
Universal Serial Bus
CDMA-2X-11004-3
Preliminary
Appendix
Page 41 of 43
LISA-C200 & FW75-C200 - System Integration Manual
Related documents
[1]
[2]
[3]
LISA-C200 Data Sheet, Docu No CDMA-2X-11001
FW75 Data Sheet, Docu No CDMA-1X-11006
u-blox C200 AT Commands Manual, Docu No CDMA-2X-11002
[4]
ITU-T Recommendation V.24, 02-2000. List of definitions for interchange circuits between data
terminal equipment (DTE) and data circuit-terminating equipment (DCE).
http://www.itu.int/rec/T-REC-V.24-200002-I/en
3GPP TS 27.007 - AT command set for User Equipment (UE) (Release 1999)
3GPP TS 27.005 - Use of Data Terminal Equipment - Data Circuit terminating; Equipment (DTE - DCE)
interface for Short Message Service (SMS) and Cell Broadcast Service (CBS) (Release 1999)
3GPP TS 27.010 - Terminal Equipment to User Equipment (TE-UE) multiplexer protocol (Release 1999)
3GPP TS 23.060 - General Packet Radio Service (GPRS); Service description; Stage 2 (Release 1999)
Universal Serial Bus Revision 2.0 specification, http://www.usb.org/developers/docs/
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
I2C-Bus Specification Version 2.1 Philips Semiconductors (January 2000),
http://www.nxp.com/acrobat_download/literature/9398/39340011_21.pdf
GPS Implementation Application Note, Docu No GSM.G1-CS-09007
CENELEC EN 61000-4-2 (2001): “Electromagnetic compatibility (EMC) - Part 4-2: Testing and
measurement techniques - Electrostatic discharge immunity test”.
ETSI EN 301 489-1 V1.8.1: “Electromagnetic compatibility and Radio spectrum Matters (ERM);
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common
technical requirements”
ETSI EN 301 489-7 V1.3.1 “Electromagnetic compatibility and Radio spectrum Matters (ERM);
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 7: Specific
conditions for mobile and portable radio and ancillary equipment of digital cellular radio
telecommunications systems (GSM and DCS)“
Some of the above documents can be downloaded from u-blox web-site (http://www.u-blox.com).
Revision history
Revision
Date
Name
Status / Comments
11/24/11
rcam
Initial Release
5/23/2012
smoi
Updated product names
7/9/2012
smoi
Unification of SIM nomenclature
8/20/2012
smoi
Document status change
CDMA-2X-11004-3
Preliminary
Related documents
Page 42 of 43
LISA-C200 & FW75-C200 - System Integration Manual
Contact
For complete contact information visit us at www.u-blox.com
u-blox Offices
North, Central and South America
u-blox America, Inc.
Phone:
+1 (703) 483 3180
E-mail:
info_us@u-blox.com
Regional Office West Coast:
Phone:
+1 (703) 483 3184
E-mail:
info_us@u-blox.com
Headquarters
Europe, Middle East, Africa
u-blox AG
Phone:
+41 44 722 74 44
E-mail:
info@u-blox.com
Support: support @u-blox.com
Technical Support:
Phone:
E-mail:
+1 (703) 483 3185
support_us@u-blox.com
Asia, Australia, Pacific
u-blox Singapore Pte. Ltd.
Phone:
+65 6734 3811
E-mail:
info_ap@u-blox.com
Support: support_ap@u-blox.com
Regional Office China:
Phone:
+86 10 68 133 545
E-mail:
info_cn@u-blox.com
Support: support_cn@u-blox.com
Regional Office Japan:
Phone:
+81 3 5775 3850
E-mail:
info_jp@u-blox.com
Support: support_jp@u-blox.com
Regional Office Korea:
Phone:
+82 2 542 0861
E-mail:
info_kr@u-blox.com
Support: support_kr@u-blox.com
Regional Office Taiwan:
Phone:
+886 2 2657 1090
E-mail:
info_tw@u-blox.com
Support: support_tw@u-blox.com
CDMA-2X-11004-3
Preliminary
Contact
Page 43 of 43

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : alaudani
Create Date                     : 2012:12:19 15:09:02-08:00
Modify Date                     : 2012:12:19 15:09:02-08:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : alaudani
Title                           : Microsoft Word - LISAC200-FW75C200_SystemIntegrationManual_(CDMA-2X-11004).docx
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 10.1.4 (Windows)
Document ID                     : uuid:b9508aac-0012-419b-bbd6-fe56277208b0
Instance ID                     : uuid:62fada52-f3f0-49c1-9c09-75cbca7671a2
Page Count                      : 43
EXIF Metadata provided by EXIF.tools
FCC ID Filing: R5Q-LISAC200A

Navigation menu