Acroprint Time Recorder 1207 Proximity Reader User Manual 111303 Qstart
Acroprint Time Recorder Company Proximity Reader 111303 Qstart
Contents
- 1. User Info Box
- 2. User Manual
- 3. Marketing User Info
User Manual
ATRx ProxTime Quick Start www.acroprint.com Getting Started You will need the following items: • Attendance Rx™ software (may already be installed, PN: 08-0137-000) • ATRx ProxTime™ (ATRx 10 Proximity Terminal, PN: 01-0206-000) • 50 ft. RS232 ATR Communications Cable provided by Acroprint (PN: 72-0146-004) • RJ11/DB 9-pin ATR Serial Adapter provided by Acroprint (PN: 63-0163-003) • DC 12V Power Adapter (PN: 56-0126-000) • 15 Proximity Badges (PN: 14-0123-002) Attendance Rx must be installed prior to initial setup and connection of ATRx10 proximity terminal. If software is already installed proceed to step 2 of Quick Start. If not, install Attendance Rx software by inserting CD into CD-Rom. Follow and complete the installation wizard. Connect ATRx10 to IBM Compatible PC 1. Make sure PC is completely shut off. To avoid damage to the PC port; PC power must be completely shut off prior to attaching the ATR adapter and ATR communications cable. 2. Connect ATR adaptor and ATR communications cable (this may already be connected at the factory). 3. Connect the ATR adapter to the serial port on the back of your PC. 4. Connect ATR communications cable to the white port on the back of the ATRx10 proximity terminal. ** Do not connect to telephone wall outlet. ** Do not connect to modem port. 5. Plug DC 12V Power Adapter into the back of the ATRx10 proximity terminal. ATRx10 will display PC on the LCD screen until your PC is powered ON and the Attendance Rx program is running. To ensure PC meets the minimum system requirements, see product box or refer to www.acroprint.com. Verify Terminal is Communicating with PC Software may automatically locate the PC serial port. After the start-up sequence the Time and Day of Week will display on the ATRx10 screen. Power Connection Note: If the connection fails the letters PC will display on ATRx10 screen. If this occurs, repeat steps in Quick Start step 2 to ensure connections are correct and proceed to Trouble Shooting portion on the reverse side of the Quick Start. Power on your PC and Attendance Rx should be running. To confirm software is running, a System Tray Icon will appear in the bottom right-hand corner of your computer desktop screen To enable ATRx Terminal Manager, right click the System Tray icon, select Enable Terminal Manager. After following these steps, your set-up should look like this diagram. *Use enclosed wall template and four screws to mount unit to wall stud. ATRx ProxTime Quick Start www.acroprint.com Connecting Additional Terminals Make sure PC power is ON and the Attendance Rx software program is running (see step 2 on reverse side of this Quick Start ). Plug communications cable into the available black port on the ATRx10 terminal. Connect the other end of the cable into the first black port on the ATRx20 terminal. *This cable is design for RS485 communications. It is available for purchase through Acroprint, please call for more information (1.800.334.7190). Insert the Terminator Plug into the remaining open RS485 port on the last ATRx20 terminal that is on the chain of terminals. Plug DC 12V power adapter into the back of the ATRx20 and the wall outlet. Time and Day of Week will display on the screen of the ATRx 20 terminal, if connection is established. Troubleshooting the ATRx10 and ATRx20 Terminal Connections Verify you are using the equipment supplied by Acroprint: connections cable, serial adapter, power adapter. Verify program is running. Refer to Step 2 of Quick Start (reverse side of this document). Check connections on the back of the PC to confirm the adapter and cable supplied by Acroprint are securely attached to a serial communications port. Confirm the cable supplied by Acroprint is plugged into the correct port on the ATRx terminal. Cycle the power to the ATRx terminal by unplugging the DC 12V power adapter from wall outlet for two to five seconds, then plug back into the wall outlet. Restart Windows. Once computer login is complete, verify program is running (Refer to Step 2 of Quick Start). Any additional questions, contact Acroprint’s Technical Support Department. FAX: 919.872.5967 WEB: www.support.acroprint.com TOLL FREE: 1.800.334.7190, option 3. EMAIL: supportdept@acroprint.com NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe A est conforme a la norme NMB-003 du Canada.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2003:12:01 10:14:47 Producer : Acrobat Distiller 4.05 for Windows Title : 111303_Qstart Subject : 111303_Qstart Author : ARobbins Creator : Adobe PageMaker 7.0 Modify Date : 2003:12:01 10:14:51-05:00 Page Count : 2EXIF Metadata provided by EXIF.tools