Coulisse ABC05 Motor for indoor blinds User Manual ABC 18 U indd

Coulisse B.V. Motor for indoor blinds ABC 18 U indd

manual 3

Download: Coulisse ABC05 Motor for indoor blinds User Manual ABC 18 U indd
Mirror Download [FCC.gov]Coulisse ABC05 Motor for indoor blinds User Manual ABC 18 U indd
Document ID1703512
Application IDzv3hnKocAt3qXM/DaMa/DA==
Document Descriptionmanual 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize123.02kB (1537760 bits)
Date Submitted2012-05-22 00:00:00
Date Available2012-06-01 00:00:00
Creation Date2017-10-31 14:11:37
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-10-31 14:11:37
Document TitleABC-18-U.indd
Document CreatorPScript5.dll Version 5.2.2
Document Author: Irene

2. Programming and operation
2.2 Operation
- Manual operation
2.1 First use
User manual
Tilt-only motor 35-50
ABC-18
Step 1: Connect the motor to 12 - 24 V DC
>2 sec
Press and hold
the program button
for at least 2 sec.
Blind is moving
In order to make the blind move in
as long as
the other direction, release the button
the button remains
and press and hold the button once
pressed (max. 15 sec.)
more for at least 2 sec.
2.3 Reset
- Reset to factory defaults
Step 2:
Set the blind in program mode by pressing the program button
(also possible with SingleSelect, See manual remote control)
10 sec
1 sec
WARNING: Important safety instructions. Follow all instructions,
since incorrect installation can lead to severe injury.
Shortly press
program button
(<2 sec.)
1 sec
WARNING: Do not make repairs yourself. Do not attempt to open the device
or disassemble it. You run the risk of electric shock and voiding
the limited warranty. No user-serviceable parts are inside.
Program mode:
blind is stepping…
Press and hold
the program button for 10 sec.
until the blind stops stepping
- Reset to factory defaults & erase all paired channels/remote controls
Set in program mode:
shortly press
program button
Program mode:
blind is stepping…
Step 3: Pair blind to channel/remote control
1 sec
indoor use only
Action confirmed:
blinds stop
stepping
for 3 sec.
1. General information
The ABC-18 is a universal tilt-motor for 35 mm and 50 mm venetian blinds.
The motor is placed in the middle of the head rail.
Select channel
with Channelselect
button
1.1 Dimensions
15 sec
Shortly press
program button
(<2 sec.)
Program mode:
blind is stepping…
Press and hold
the program button for 15 sec.
until the blind stops stepping
and steps once again.
2.4 Advanced settings
Pair/unpair by pressing
the program button on the back side
of the remote control
Advanced settings:
Step 4: Switch direction of rotation
Available
Switch rotation direction
Yes
Favourite position
Yes
BatteryMode
Yes
25 mm
38 mm
See manual remote control for programming of advanced settings.
Action confirmed:
blinds stop
stepping
for 3 sec.
120 mm
35 mm
3. Tips & Troubleshooting
Please check www.coulisse.nl for the latest tips and troubleshooting guide.
4. Safety & Cleaning
4.1 Safety
Press the up and down button
at the same time to switch
the direction of rotation
1.2 Specifications
WARNING: Do not make repairs yourself. Do not attempt to open the device
or disassemble it. You run the risk of electric shock and voiding
the limited warranty. No user-serviceable parts are inside.
ABC-18
Power supply
Rated power
3W
Torque (rpm)
0.65Nm
Operating temperature
Max. number of channels
Step 5: Programming end positions
12-24V - 0,3 A
First program the upper position
5 - 60 °
32 channels
1.
2.
1.3 Power supply and buttons
Action confirmed:
blinds stop
stepping
for 3 sec.
Use the up and down
button to go to
the upper position
12 - 24 V DC -0.6A input
5. Service & Support
WARNING: Do not make repairs yourself. Do not attempt to open the device
or disassemble it. You run the risk of electric shock and voiding
the limited warranty. No user-serviceable parts are inside.
Now program the lower position
1.
Program button
Use the up and down button
to go to the lower position
- Do not let children play with the blind and/or remote control.
- Only use powersupplies or batteries that comply with the specifications on the motor.
- In case of malfunction, unplug the device or remove the batteries and contact your dealer.
- Take care that the blind can move freely and is not blocked by objects.
- Take care that the powersupply cable is out of reach for children.
- Do not paint the device.
- Keep the device dry.
4.2 Cleaning
Follow these general rules when cleaning the outside of the device and its components:
- Make sure the device is unplugged.
- Use a damp, soft, lint-free cloth. Avoid getting moisture in openings.
- Don’t use aerosol sprays, solvents, alcohol, or abrasives.
2.
Confirm the position
by pressing the middle and
down button
Action confirmed:
blinds stop
stepping
for 3 sec.
Online Resources
For the latest information and updated manuals go to www.coulisse.nl.
Obtaining Warranty Service
First follow the advice in this booklet and then go to your local dealer.
If the product appears to be damaged or does not function properly, go to your
local dealer for instructions on how to obtain warranty service.
Disclaimer:
© Copyright Coulisse
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, by any means, electronic,
mechanical, photocopying, recording, digital or otherwise without the written permission of the publisher.
Although this manual has been composed with the most care, Coulisse B.V. does not accept any responsibility for damage due
Coulisse B.V. reserves the right to revise the manual and to revise and/or changes its content at any time, without obligation to notify
any person or entity of such revisions or changes.
Coulisse B.V., Vonderweg 48, 7468 DC Enter, The Netherlands
Exit program mode:
shortly press program button
The most recent version replaces older versions of this manual. The most recent version is available at ww.coulisse.nl or contact
your Coulisse contact person.
We invite you to send remarks and comments about this manual to Coulisse at manuals@coulisse.nl.
ABC-18-A_R0_GB0
to mistakes and/or faults in this manual.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Copy, Extract, Print high-res
Author                          : Irene
Create Date                     : 2010:10:05 09:50:27+02:00
Modify Date                     : 2010:10:05 09:50:57+02:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2010:10:05 09:50:57+02:00
Format                          : application/pdf
Title                           : ABC-18-U.indd
Creator                         : Irene
Document ID                     : uuid:0eadb996-b544-42e3-a274-18b217fdd1b7
Instance ID                     : uuid:a2f3cc42-8400-4841-9179-ad9231bf834b
Page Count                      : 1
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZY4ABC05

Navigation menu