Fukuda Denshi Co DS7100 Patient Monitor User Manual DS71v1 1 FA 02 Operation 004

Fukuda Denshi Co Ltd Patient Monitor DS71v1 1 FA 02 Operation 004

User manual 3

Download: Fukuda Denshi Co DS7100 Patient Monitor User Manual DS71v1 1 FA 02 Operation 004
Mirror Download [FCC.gov]Fukuda Denshi Co DS7100 Patient Monitor User Manual DS71v1 1 FA 02 Operation 004
Document ID380405
Application IDwOVnFJBjOncRtHtUy8lSFQ==
Document DescriptionUser manual 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize188.55kB (2356857 bits)
Date Submitted2003-12-10 00:00:00
Date Available2003-12-10 00:00:00
Creation Date2003-12-06 11:43:00
Producing SoftwareAcrobat PDFWriter 4.0 Windows NT
Document Lastmod2003-12-06 15:08:32
Document TitleDS71v1-1_FA_02_Operation_004.PDF
Document CreatorMicrosoft Word - DS71v1-1_FA_02_Operation_004.doc
Document Author: ezashi

Press the ID key.
Enter the ID number using the numeric keypad.
Press the Age key.
Enter the birth date using the numeric keypad.
4. Select the patient type, and
Used
Not used
of pacemaker use.
Select the patient type from Adult , Child ,
or Neonate .
Select the pacemaker use from Used ,
Not used .
The patient type and pacemaker use must be selected. The patient type
W A R N I N G selection influences the precision of the QRS detection and NIBP
measurement. Make sure the correct selection is made.
2−11
To Start Monitoring
3. Enter the patient’s birth date.
− Basic Operation −
Scale, Lead, Baseline Position Setup (Parameter Key)
1. Select the parameter to set the scale / lead / baseline position. (Ex.: ECG)
Press the parameter key where heart rate is displayed.
2. Press the Lead・Size
displayed.
key. The menu to adjust size / lead / baseline position will be
3. Adjust the waveform size.
Select an appropriate waveform size for the monitoring waveform.
The arrhythmia detection level corresponds with the displayed waveform
C A U T I O N size. Select an appropriate size for monitoring.
2−12
4. Select the lead.
Select an appropriate lead according to the monitoring purpose.
Basic Operation
5. Adjust the baseline position.
Use the ? , ? keys to adjust the waveform baseline position.
Reference
Use the same procedure for each parameter.
Refer to section for each parameter in “6. Parameter Setup”.
2−13
Scale, Lead, Baseline Position Setup (User Key)
Pressing the Lead・Size key will display the
arrow keys on the home display to adjust
waveform size, scale, lead, baseline position.
1. Select the waveform size, lead, baseline position for ECG waveform.
Adjust the waveform suitable for monitoring.
Pressing the Lead key will sequentially change
the lead.
3-electrode:Ⅰ→Ⅱ→Ⅲ→Ⅰ
4-electrode:Ⅰ→Ⅱ→Ⅲ→aVR→aVL→aVF→Ⅰ
5-electrode:Ⅰ→Ⅱ→Ⅲ→aVR→aVL→aVF→V→Ⅰ
Pressing the Size key will sequentially change the
size.
×1/4→×1/2→×1→×2→×4→×1/4
Use the ↑ , ↓ keys to adjust the baseline position
up or down.
2. Select the scale for BP, CO2 waveform.
Pressing the
scale.
Scale
key will sequentially switch the
3. Select the waveform size for impedance respiration waveform, SpO2 waveform.
Pressing the Size key will sequentially change the
size.
×1/4→×1/2→×1→×2→×4→×1/4
2−14
Alarm Setup for Each Parameter
The alarm can be set for each parameter. By pressing the selected parameter key, upper and
lower alarm limit and ON/OFF of alarm can be set.
1. Select the parameter to set the alarm. (Ex.: HR alarm)
Basic Operation
2. Press the
HR Alarm
key. The menu to adjust the alarm limit will be displayed.
3. Set the upper and lower alarm limit.
Use the
? ,
keys to adjust the lower limit.
? ,
keys to adjust the upper limit.
Lower Limit
Use the
Upper Limit
Reference
Use the same procedure for the setup of each parameter.
Refer to section for each alarm in “6. Parameter Setup”
2−15
ON/OFF of Parameter Display
Waveform/Numeric Data Display
The waveform and numeric data display for each parameter can be turned ON or OFF without
changing the display configuration. If not performing the ECG or SpO2 measurement while the
ECG cable or SpO2 sensor is connected to the monitor, the equipment status alarm such as “Lead
Off” will generate. Removing ECG or SpO2 from the display configuration will not generate such
alarm, but this function may be more useful as it allows to turn off the measurement without
changing the display configuration.
This function is not available for NIBP monitoring.
1. Select the parameter to turn off the display. (Ex.: ECG)
2. Press the Display ON/OFF
will appear.
3. Select
Display ON
or
key. The confirmation display for ON/OFF of ECG display
Display OFF .
Pressing the Display ON key will display the
waveform and numeric data.
Pressing the Display OFF key will not display the
waveform and numeric data.
The Display OFF message will be
displayed inside the parameter key.
4. Automatic reset
For ECG, impedance RESP, SpO2, CO2, properly connecting the sensor will automatically set the
display ON/OFF function to “Display ON”.
Reference
2−16
For automatic reset condition, refer to Display ON/OFF section for each parameter in
“6. Parameter Setup”.
Recording
●Start / Stop of Waveform Recording
Pressing the Rec. START/STOP key on the
home display will start the waveform recording.
Up to 3 waveforms can be recorded.
Basic Operation
【Example of Recording】
Recorded Time
Sex
Age
Patient ID
Patient Type
Measured Data
Bed ID
Patient Name
Waveform Type, Lead, Size
Recording Speed
Rec. Mode
Delay Time
Telemetry Channel
Filter Mode
For the manual recording, number of recording waveforms and recording duration can be set.
Refer to “4. Monitoring Setup Manual Recording” for details.
Reference
For the alarm recording, number of recording waveforms, recording duration, alarm factor can be
set.
Refer to “4. Monitoring Setup Alarm Recording” for details
For the periodic recording, number of recording waveforms, recording duration, recording
intervals can be set.
Refer to “4. Monitoring Setup Periodic Recording” for details.
The monitoring data of the patient such as graphic trend and tabular trend can be recorded.
Refer to sections on graphic trend and tabular trend in “7. Function”.
2−17
To Install the Paper
1. Press the button located at the right side of the recorder magazine.
2. The magazine will come out.
3. Pull out the magazine from the monitor.
4. Set the recording paper so that the mark printed on each paper comes to the right.
Mark
5. Place the magazine back into the monitor. Push in until it locks into place with a click
sound.
2−18
To Suspend Monitoring
When not monitoring for a while, turning OFF the power will erase the recall data, ST
measurement, OCRG data.
However, using the cease monitoring function allows suspension of data measurement, alarm
generation, automatic measurement, automatic recording without erasing the data or setup
details.
1. Press the Cease key on the admit / discharge menu.
Press the Menu → Admit / Discharge →
Cease key.
Basic Operation
2.
Suspend monitoring.
Pressing the OK key on the confirmation
display will interrupt monitoring.
Pressing the Cancel key will return to the
previous display.
3. Verify that the monitoring is suspended.
The Resume key will be displayed on the
home display. On the home display, numeric
data and waveform display will be ceased, and
all the key operation except the Resume
key will become ineffective.
NOTE
The telemetry transmission will cease when monitoring is suspended.
(for DS-7141, DS-7101LT)
Note that the square wave will be displayed on the central monitor indicating the
too far condition of the telemetry.
2−19
Discharging Procedure
This procedure will erase the past data, such as patient name, ID, age, tabular / graphic trend, and
recall.
1. Press the
Discharge
key on the admit / discharge menu.
Press the Menu →
Discharge key.
Admit / Discharge
2. Perform discharge procedure.
Pressing the OK key on the confirmation
display will discharge the patient.
Pressing the Cancel key will return to the
previous display.
2−20
→
− Operation Flow −
The operation flow of this system is as follows.
【Menu】
Admit /Discharge
Patient Name / ID / Sex
Patient Type (Adult / Child / Neonate)
Age
Graphic Trend
Tabular Trend
NIBP List
Recall
ST Display
Room / Bed ID
Pacemaker
Filter Mode
Operation Flow
Parameter Setup
Discharge
Mode Selection
Cease Monitor
Zero Balance
OCRG
Alarm Setup
Volume Setup
Display Configuration
Night Mode
Other Bed
【System Configuration】
Night Mode Setup
Record Setup
Sweep Speed
Brightness Setup
IC Card
Color Setup
Telemetry Waveform Setup
【Preset】
Alarm Mode Setup
Hospital Setup
Ward Setup
Monitor Setup
Display Mode Setup
Test Menu
2−21
Blank Page
2−22

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2003:12:06 11:43:00Z
Modify Date                     : 2003:12:06 15:08:32+09:00
Page Count                      : 12
Creation Date                   : 2003:12:06 11:43:00Z
Author                          : ezashi
Producer                        : Acrobat PDFWriter 4.0 Windows NT
Mod Date                        : 2003:12:06 15:08:32+09:00
Metadata Date                   : 2003:12:06 15:08:32+09:00
Title                           : DS71v1-1_FA_02_Operation_004.PDF
Creator                         : ezashi
EXIF Metadata provided by EXIF.tools
FCC ID Filing: DV8DS7100

Navigation menu