Gantner Electronic GEA1150002A Access Control Terminal, Access Control Terminal with Biometry User Manual Brochure 6100
Gantner Electronic GmbH Access Control Terminal, Access Control Terminal with Biometry Brochure 6100
Contents
- 1. User Manual
- 2. Brochure 6100
- 3. Brochure 6100F
Brochure 6100
GAT Access 6100 Access Control Terminal Application The GAT Access 6100 is a stylish terminal for access control in leisure facilities such as swimming pools, spas and gyms. Identification at the terminal is by contact-free RFID data carrier (Radio Frequency Identification). Information display for user guidance is realised via a graphical mono chrome display (LCD). The different versions (see order information) give technological flexibility. Function description Order information The GAT Access 6100 reads contact-free data carriers and checks and Description grants authorisations. The user holds the data carrier over the round scan field and selects the required service via the acknowledge key. The integrated 4-segment LED display, monochrome LCD display and acoustic signal indicate authorisation. Further functions: • Activation of turnstiles, doors etc. via relay output • Feedback input • User guidance via monochrome display (LCD), 4-segment LED display, illuminated round scan field and beeper • Secure data transmission between reader and data carrier • RFID frequency 13.56 MHz • Reading of LEGIC®, MIFARETM standard and ISO 15693 data carriers GAT Access 6100 B PartNo. 651681 Access control terminal with monochrome display (LCD) and contact-free reader for LEGIC® data carriers GAT Access 6100 F 776487 Access control terminal with monochrome display (LCD) and contact-free reader for MIFARETM data carriers GAT Access 6100 ISO 651782 Access control terminal with monochrome display (LCD) and contact-free reader for ISO 15693 data carriers (depending on the device type) • Opening of housing only possible with special tool • Plug & Play installation Accessories Description PartNo. GAT Access 6100 Manual 332727 Operating and configuration instructions, English GAT Reader WK 581683 Tool to open the reader housing www.gantner.com Valid as from July 30 th , 2013 • Technical data subject to modifications without notice! DB_GAT-ACCESS6100--EN_11.indd • PartNo.: 860279 Technical data Nominal voltage: 12/24 VDC (SELV - safety extra-low voltage) Permitted input voltage: 10 to 28 VDC Aver. power consumption: 3W Data storage: Internal EEPROM memory for configuring and booking memory, data preservation min. 10 years Internal clock: Data preservation approx. 12 h (Gold-Cap) Reader type: See order information Frequency of reading field: Control elements: Display elements: - Full graphics monochrome display (LCD) with white LED background lighting, resolution 128 x 64 pixels, visible area 50 x 25 mm - RFID reader (illuminated) - Acoustic signal - 4-segment LED display with different colours Host interface: Signal input: 1 x optocoupler (configurable) - Input voltage: 0 to 30 VDC ULow < 2 VDC, UHigh > 6 VDC - Input current: 4.5 mA Signal output: 1 x relay (configurable NO/NC) - Switching voltage: max. 30 VAC/DC - Continuous current: max. 2 A - Switching power: max. 60 VA Connection terminals: 0.5 to 1.5 mm 2 Housing material: - Upper part: plastic PMMA - Back part: plastic PC-ABS 13.56 MHz Dimensions: 93 x 107 x 33 mm - 4 function keys - RFID reader Permitted ambient temperature: -10 to +55°C Storage temperature: -20 to +70°C Relative humidity: 20 to 80%, non-condensing Protection type: IP 54 Protection class: III Weight: 0.2 kg Environment class based on VDS 2110: II (conditions in indoor areas) Ethernet 10/100 MBit/s Dimensions 24 mm (0.94”) 1. 4-segment LED display 2. Monochrome display (LCD) 3. Function keys 107 mm (4.2”) 4. Illuminated, round scan field 5. Device back part 6. Device upper part 93 mm (3.66”) 33 mm (1.3”) Typical application GAT Access 6100 Power supply Network Turnstile RFID data carriers Valid as from July 30 th , 2013 • Technical data subject to modifications without notice! DB_GAT-ACCESS6100--EN_11.indd • PartNo.: 860279 www.gantner.com Mounting and installation instructions The device back part is secured by screws to a flat background (e.g. Wall mounting concrete wall). When fixing to an uneven background the device back part Cables can be flush (1) or suface-mounted (2). must not be distorted as this will prevent correct connection of the upper When surface mounting please check whether the cables can still be part. Recommended mounting height: top edge of device 1.3 m. inserted once the device back part has been mounted, otherwise run the Use the drilling template which is attached to the device. cables through the cable lead-ins prior to securing. 69 mm (2.72”) 71 mm (2.8”) 28.5 mm (1.12”) 20 mm (0.79”) 18.5 mm (0.73”) 60 mm (2.36”) 1. Flush-mounted cable 2. Surface-mounted cable 3. Back box 4. Device back part 5. Cable conduit for surface cable connection 13 mm (0.51”) Mounting the device upper part Once the connection cables are terminated, the device back part and upper part are connected together via a connection cable (already connected in the upper part) and the two parts are fixed together. 1. 2. 3. 4. Notes: 1. Check the socket in the device back part (circled in figure 1). Dirt, 3. Swing down the device upper part until it clicks. dust and humidity must be removed so that a good contact of the 4. The device can only be opened with the supplied special tool! With connection cable is guaranteed. No aggressive detergent may be this the two catches on the bottom of the device can be unlocked in used. Please do not damage socket contacts. succession. Attention: Cleaning only in powerless state. 2. Plug in the connection cable into the socket in the device back part (consider alignment) and clip the top of the device upper part into the device back part. www.gantner.com Valid as from July 30 th , 2013 • Technical data subject to modifications without notice! DB_GAT-ACCESS6100--EN_11.indd • PartNo.: 860279 Electrical connections TCP/IP with external power supply GAT Access 6100 e.g. Turnstile GND VOut+ Mains power Motor control Power supply unit e.g. GAT Power Supply SP014/1 TX + TX RX + RX - GND C1 NO 1 VIN + IN1 + IN1 - Feedback control TCP/IP Network Relay output Ethernet, Connection via screw terminals. For activation of devices like turnstiles etc.. The relay contact is of type NO (maker contact). Please observe the max. permitted switching voltages Power supply and currents (see technical data). DC supply (see technical data), e.g. via GANTNER GAT Power Supply Depending on the connected instalation (e.g. turnstile) an additional free SP014/1. The power input is protected against reverse-polarity. wheeling diode may be necessary, which is used to limit the switch-on current. Please read the documentation of the connected installation. Recommended cables: Ethernet: min. CAT 5 (STP) for 100 MBit Optocoupler input Input for status acquisition. For using the input a supply voltage must be Wire colours applied. This voltage can be taken from the terminal‘s supply or from an Ethernet 10/100 MBit external power source. Please observe the max. permitted input voltages 568A 568B and currents (see technical data). TX + green/white orange/white TX - green orange RX + orange/white green/white RX - orange green Connection to the device upper part Attention: The socket (3) for the connection cable between the device back part and the device upper part must be clean in order to guarantee a good contact. Safety instructions - This device must be installed by qualified personnel only. - The applicable safety and accident prevention regulations must be observed. - Safety devices must not be removed. - Please observe the technical data of the device specified on the data sheet. - The device must be disconnected from the power supply prior to installation, assembly or dismantling. Valid as from July 30 th , 2013 • Technical data subject to modifications without notice! DB_GAT-ACCESS6100--EN_11.indd • PartNo.: 860279 www.gantner.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.2-c003 61.141987, 2011/02/22-12:03:51 Create Date : 2013:08:02 10:06:05+02:00 Modify Date : 2013:08:02 10:06:07+02:00 Metadata Date : 2013:08:02 10:06:07+02:00 Creator Tool : Adobe InDesign CS5.5 (7.5) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 7792 bytes, use -b option to extract), (Binary data 7377 bytes, use -b option to extract) Instance ID : uuid:e5f4cece-de29-4964-8b10-17598afbb611 Original Document ID : adobe:docid:indd:d7deda35-b151-11e1-b454-efcd238f4309 Document ID : xmp.did:79E3999D18F9E21194E1F8096BE2D916 Version ID : 1 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:78E3999D18F9E21194E1F8096BE2D916 Derived From Document ID : xmp.did:46433CD716F9E21194E1F8096BE2D916 Derived From Original Document ID: adobe:docid:indd:d7deda35-b151-11e1-b454-efcd238f4309 Derived From Version ID : 1 Derived From Rendition Class : default History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:89D8A894C9AFE11189B2FCCDE2836EE5, xmp.iid:8AD8A894C9AFE11189B2FCCDE2836EE5, xmp.iid:5AAF37D716F9E21194E1F8096BE2D916, xmp.iid:46433CD716F9E21194E1F8096BE2D916, xmp.iid:47433CD716F9E21194E1F8096BE2D916, xmp.iid:78E3999D18F9E21194E1F8096BE2D916, xmp.iid:79E3999D18F9E21194E1F8096BE2D916, xmp.iid:7AE3999D18F9E21194E1F8096BE2D916, xmp.iid:D44EC4111AF9E21194E1F8096BE2D916, xmp.iid:5A11D1151AF9E21194E1F8096BE2D916, xmp.iid:D70D0D3B1AF9E21194E1F8096BE2D916, xmp.iid:B4D9D7D125F9E211B67ED2B328B26BF9, xmp.iid:95E2FEB526F9E211B67ED2B328B26BF9, xmp.iid:96E2FEB526F9E211B67ED2B328B26BF9, xmp.iid:D2CC2B3728F9E211B67ED2B328B26BF9, xmp.iid:361C25B129F9E211B67ED2B328B26BF9, xmp.iid:F3FBBE6D2AF9E211B67ED2B328B26BF9, xmp.iid:8231ADAE2AF9E211B67ED2B328B26BF9, xmp.iid:458A411EB8F9E211B520E82860B46321, xmp.iid:2436385D4AFBE2119A8B98853CEB123B History When : 2012:06:06 13:20:11+02:00, 2012:06:06 13:20:11+02:00, 2013:07:30 14:52:06+02:00, 2013:07:30 14:52:07+02:00, 2013:07:30 15:04:44+02:00, 2013:07:30 15:05:55+02:00, 2013:07:30 15:05:55+02:00, 2013:07:30 15:13:44+02:00, 2013:07:30 15:15:13+02:00, 2013:07:30 15:15:20+02:00, 2013:07:30 15:16:22+02:00, 2013:07:30 16:39:20+02:00, 2013:07:30 16:45:43+02:00, 2013:07:30 16:50:38+02:00, 2013:07:30 16:56:29+02:00, 2013:07:30 17:07:03+02:00, 2013:07:30 17:12:19+02:00, 2013:07:30 17:14:08+02:00, 2013:07:31 10:06:35+02:00, 2013:08:02 10:05:58+02:00 History Software Agent : Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5 History Changed : /;/metadata, /metadata, /metadata, /;/metadata, /;/metadata, /metadata, /, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata Format : application/pdf Description : 20130730 (WER): Artikelnummer Handbuch dazu (Seite 1), MIFARE (TM) statt (R), Inch-Maße dazu (Seite 2 und 3).20130730 (WER): Leistungsaufnahme von 10 W auf 3 W geändert (Seite 2).20130730 (WER): Anschlussbild Seite 4 geändert (Kontakt Drehkreuz).FREIGABE V1.0 Doc Change Count : 2388 Producer : Adobe PDF Library 9.9 Trapped : False Page Count : 4 Creator : Adobe InDesign CS5.5 (7.5) Subject : 20130730 (WER): Artikelnummer Handbuch dazu (Seite 1), MIFARE (TM) statt (R), Inch-Maße dazu (Seite 2 und 3).20130730 (WER): Leistungsaufnahme von 10 W auf 3 W geändert (Seite 2).20130730 (WER): Anschlussbild Seite 4 geändert (Kontakt Drehkreuz).FREIGABE V1.0EXIF Metadata provided by EXIF.tools