Gantner Electronic GEA1150002A Access Control Terminal, Access Control Terminal with Biometry User Manual Brochure 6100F

Gantner Electronic GmbH Access Control Terminal, Access Control Terminal with Biometry Brochure 6100F

Contents

Brochure 6100F

Download: Gantner Electronic GEA1150002A Access Control Terminal, Access Control Terminal with Biometry User Manual Brochure 6100F
Mirror Download [FCC.gov]Gantner Electronic GEA1150002A Access Control Terminal, Access Control Terminal with Biometry User Manual Brochure 6100F
Document ID2737705
Application IDPP37ZG2zteOhweVeEdzhuw==
Document DescriptionBrochure 6100F
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize106.19kB (1327400 bits)
Date Submitted2015-09-02 00:00:00
Date Available2016-02-28 00:00:00
Creation Date2013-08-02 10:14:50
Producing SoftwareAdobe PDF Library 9.9
Document Lastmod2013-08-02 10:14:53
Document TitleBrochure 6100F
Document CreatorAdobe InDesign CS5.5 (7.5)

GAT Access 6100 F
Access Control Terminal with Biometry
Application
The GAT Access 6100 F with fingerprint reader GAT FR 055 is a stylish
terminal for access control in leisure facilities such as swimming pools,
spas and gyms. Identification at the terminal is by contact-free RFID data
GAT Access 6100 F
carrier (Radio Frequency Identification).
With the fingerprint reader GAT FR 055 access control is extended by
verification with biometric data, which enables optimal protection against
misuse of personal data carriers.
Information for user guidance is displayed via a graphical monochrome
display (LCD).
Fingerprint reader
GAT FR 055
Function description
Order information
The GAT Access 6100 F reads contact-free data carriers and checks
Description
PartNo.
GAT Access 6100 F
776487
and grants authorisations. The user holds the data carrier over the round
scan field and selects the required service via the acknowledge key. The
integrated 4-segment LED display, monochrome LCD display and acoustic
signal indicate authorisation.
Via the fingerprint reader GAT FR 055 the identification of the visitors
is verified by comparing their fingerprints with the fingerprint templates
(two templates per visitor) stored on the visitor‘s personal data carriers.
The combination of RFID data carriers and fingerprints allows for optimal
protection against misuse of data carriers.
For capturing the fingerprints and storing them to the data carriers the GAT
Access 6100 F Enrollment Station is used.
Terminal for entry control with integrated, contactless
MIFARETM reader, with black-white display (LCD)
GAT FR 055
557433
Fingerprint reader for GAT Access 6100 F, wall mounting
GAT FR 055 Weather Cover
174529
Weather protection cover for GAT FR 055 and
GAT FR 055 FIU 3k
Highlights
• Activation of turnstiles, doors etc. via relay output
• Feedback input
• User guidance via monochrome display (LCD), 4-segment LED display,
illuminated round scan field and beeper
• Secure data transmission between reader and data carrier
• Read/write frequency 13.56 MHz
• Reading MIFARETM Standard data carriers
• Expandabilities for verification via fingerprint
• Opening of housing only possible with special tool
• Plug & Play installation
www.gantner.com
Accessories
Description
PartNo.
GAT Access 6100 F Enrollment Station
174327
Table station for capturing fingerprints
GAT Reader WK
581683
Tool to open the reader housing
Valid as from July 31th 2013 • Technical data subject to modifications without notice!
DB_GAT-ACCESS6100F--BIO-EN_11.indd • PartNo.: 243526
Technical data
Nominal voltage:
12/24 VDC (SELV - safety extra-low
voltage)
Control elements:
- 4 function keys
- RFID reader
Permitted input voltage:
10 to 28 VDC
Host interface:
Ethernet 10/100 MBit/s
Aver. power consumption:
- Full operation sensor in: 4.5 W
- Full operation sensor out: 3.5 W
Signal inputs:
Data storage:
Internal EEPROM memory for
configuration and booking memory,
data preservation min. 10 years
1 x optocoupler (configurable)
- Input voltage: 0 to 30 VDC
ULow < 2 VDC, UHigh > 6 VDC
- Input current: 4.5 mA
Signal outputs:
Internal clock:
Data preservation approx. 12 h
(Gold-Cap)
Reader type:
MIFARETM Standard
1 x relay (configurable NO/NC)
- Switching voltage: max. 30 VAC/DC
- Continuous current: max. 2 A
- Switching power: max. 60 VA
Frequency reading field:
13.56 MHz
Connection terminals:
0.5 to 1.5 mm 2
GAT FR 055 sensor:
- Scanner type: optical sensor,
500 dpi @ 8-bit per pixel,
active area: 13 x 20 mm
- Verification time: < 0.8 sec.
- Identification time: < 1 sec.
- False acceptance rate 0.01%
(recommended), adjustable over wide
range
Housing material:
- GAT Access 6100 F: plastic
- GAT FR 055: plastic
Display elements:
- Full graphical monochrome display
(LCD) with white LED background
lighting, resolution 128 x 64 pixels,
visible area 50 x 25 mm
- RFID reader (illuminated)
- Acoustic signal
- 4-segment LED display with different
colours
Permitted ambient temperature: -10 to +55°C
Storage temperature:
-20 to +70°C
Relative humidity:
20 to 80%, non-condensing
Protection type:
IP 54
Protection class:
III
Weight:
0.2 kg
Environment class
based on VDS 2110:
II (conditions in indoor areas)
Certifications of the GAT FR 055
finger scanner:
CE and FCC15
Dimensions
93 mm (3.66”)
39.4 mm (1.55”)
33 mm (1.3”)
107 mm (4.21”)
163 mm (6.42”)
1. 4-segment LED display
2. Monochrome display (LCD)
3. Function keys
4. Illuminated, round scan field
5. Device back part
6. Device upper part
7. Fingerprint reader GAT FR 055 (optional)
8. Fingerprint sensor of the GAT FR 055
9. Weather protection cover (optional)
93 mm (3.66”)
38 mm (1.5”)
53 mm (2.09”)
Typical application
GAT Access 6100 F
Power supply
Network
Data carrier
Turnstile
Valid as from July 31th 2013 • Technical data subject to modifications without notice!
DB_GAT-ACCESS6100F--BIO-EN_11.indd • PartNo.: 243526
www.gantner.com
Mounting and installation instructions
4. Electrical connection
Drill mounting holes on a flat background (e.g. concrete wall) according to
The connection cables (see (4) in previous drawing) are connected at the
the following dimensional drawing. Use the three holes labelled (a).
device back part of the GAT Access 6100 F (se page 4).
14.1 mm (0.56”)
1. Mounting holes
94.4 mm (3.72”)
69 mm (2.72”)
60 mm (2.36”)
13 mm
(0.51”)
5. Mounting of the GAT Access 6100 F upper part
The connection cable of the GAT FR 055 (1) is fixed into the housing
upper part of the GAT Acces 6100 F and the connection cable of the
upper part (2) is fixed in the back part of the GAT Access 6100 F. After
that the device upper part can be swung down into the back part (3).
71 mm (2.8”)
157 mm (6.18”)
28.5 mm
(1.12”)
12.6 mm (0.5”)
Flush cabling
20 mm
(0.79”)
2. Connection cable
The connection cables (power supply, network etc.) are run through the
cable lead-ins of the GAT FR 055. With concealed/flush wiring (1) the
connection cables are fed from behind via the back box. With surface
wiring (2) the connection cables must lie in the cable duct on the back
Back box
part of the GAT FR 055.
Check the sockets (1) and (2)! Dirt, dust and humidity must be removed so
that a good contact of the connection cable is guaranteed. No aggressive
detergent may be used. Please do not damage socket contacts.
Attention: Cleaning only in powerless state!
6. Open the GAT Access 6100 F upper part
The GAT Access 6100 F an only be opened with the supplied special tool!
With this the two catches on the bottom of the device can be unlocked in
succession.
3. Wall mounting
Pay attention when fixing to an uneven background that the GAT FR 055
housing and the device back part of the GAT Access 6100 F must not
be distorted. Recommended mounting height: top edge of device 1.3 m.
1. GAT FR 055
2. Device back part of
GAT Access 6100 F
3. Fastening screws
4. Connection cable
Maintenance
5. Connection cable GAT FR 055
The sonsor field of the GAT FR 055 should be cleaned from time to time
to GAT Access 6100 F
so that finger prints can be clearly scanned.
6. Weather protection cover
(optional)
7. Fastening screws for weather
For cleaning the sensor field always use a humid (not wet!) smooth
cloth. No sharp or acrid detergents and no sharp materials must be
used!
protection cover
www.gantner.com
Valid as from July 31th 2013 • Technical data subject to modifications without notice!
DB_GAT-ACCESS6100F--BIO-EN_11.indd • PartNo.: 243526
Electrical connections
TCP/IP with external power supply
GAT Access 6100
e.g. Turnstile
GND
VOut+
Mains power
Motor control
Power supply unit
e.g. GAT Power Supply SP014/1
TX +
TX RX +
RX -
GND
C1
NO 1
VIN +
IN1 +
IN1 -
Feedback control
TCP/IP
Power supply
Connection to the device upper part
DC supply (see technical data), e.g. via GANTNER GAT Power Supply
Attention: The socket for the connection cable between the device back
SP014/1. The power input is protected against reverse-polarity.
part and upper part (circle with the lable (1) in the connection figure) must
be clean in order to guarantee a good contact.
Network
Ethernet, connection via screw terminals.
Relay output
For activation of devices like turnstiles etc.. the relay contact is of type NO
Recommended cables
(maker contact). Please observe the max. permitted switching voltages
Ethernet: min. CAT 5 (STP) for 100 MBit
and currents (see technical data).
Depending on the connected installation (e.g. turnstile) an additional free-
Ethernet wire colours
wheeling diode may be necessary, which is used to limit the switch-on
Ethernet 10/100 MBit
568A
current. Please read the documentation of the connected installation.
568B
TX +
green/white
orange/white
Optocoupler input
TX -
green
orange
Input for status acquisition. For using the input a supply voltage must be
RX +
orange/white
green/white
applied. This voltage can be taken from the terminal´s supply or from an
RX -
orange
green
external power source. Please observe the max. permitted input voltages
and currents (see technical data).
Usage of the fingerprint reader GAT FR 055
The sensor field will light-up red if a finger print must be scanned.
Pay attention that the finger is always pressed vertically onto the sensor
field in order to guarantee an optimal scanning of the finger! Furthermore
the finger should be laid rectangular onto the sensor field and touch the
top edge.
See also the operating instructions of the GAT Access 6100 F.
Correct:
Incorrect:
Safety instructions
- This device must be installed by qualified personnel only.
- The applicable safety and accident prevention regulations
must be observed.
- Safety devices must not be removed.
- Please observe the technical data of the device specified
on the data sheet.
- The device must be disconnected from the power supply
prior to installation, assembly or dismantling.
Valid as from July 31th 2013 • Technical data subject to modifications without notice!
DB_GAT-ACCESS6100F--BIO-EN_11.indd • PartNo.: 243526
www.gantner.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c003 61.141987, 2011/02/22-12:03:51
Create Date                     : 2013:08:02 10:14:50+02:00
Modify Date                     : 2013:08:02 10:14:53+02:00
Metadata Date                   : 2013:08:02 10:14:53+02:00
Creator Tool                    : Adobe InDesign CS5.5 (7.5)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 8102 bytes, use -b option to extract), (Binary data 8026 bytes, use -b option to extract)
Instance ID                     : uuid:666fb2c6-5e9a-4d23-b302-ec7f70d44c44
Original Document ID            : adobe:docid:indd:9a31ecbf-aec1-11e0-8d61-e9a41f966e04
Document ID                     : xmp.did:D592EDC630F9E211B67ED2B328B26BF9
Version ID                      : 1
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:6531EBC630F9E211B67ED2B328B26BF9
Derived From Document ID        : xmp.did:B39EA4AE2FF9E211B67ED2B328B26BF9
Derived From Original Document ID: adobe:docid:indd:9a31ecbf-aec1-11e0-8d61-e9a41f966e04
Derived From Version ID         : 1
Derived From Rendition Class    : default
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:D40CF1225EADE011A004E54DF7110F6E, xmp.iid:D50CF1225EADE011A004E54DF7110F6E, xmp.iid:8331ADAE2AF9E211B67ED2B328B26BF9, xmp.iid:B39EA4AE2FF9E211B67ED2B328B26BF9, xmp.iid:B49EA4AE2FF9E211B67ED2B328B26BF9, xmp.iid:A905C84B30F9E211B67ED2B328B26BF9, xmp.iid:AA05C84B30F9E211B67ED2B328B26BF9, xmp.iid:6531EBC630F9E211B67ED2B328B26BF9, xmp.iid:D592EDC630F9E211B67ED2B328B26BF9, xmp.iid:48FDD514B8F9E211B520E82860B46321, xmp.iid:D7851BE2B9F9E211B520E82860B46321, xmp.iid:3B6932C3C2F9E211B520E82860B46321, xmp.iid:0F7FF952D7F9E211B520E82860B46321, xmp.iid:4BDE7561D7F9E211B520E82860B46321, xmp.iid:2A6806964BFBE2119A8B98853CEB123B
History When                    : 2011:07:13 16:41:04+02:00, 2011:07:13 16:41:04+02:00, 2013:07:30 17:49:56+02:00, 2013:07:30 17:49:56+02:00, 2013:07:30 17:53:47+02:00, 2013:07:30 17:54:19+02:00, 2013:07:30 17:57:22+02:00, 2013:07:30 17:57:46+02:00, 2013:07:30 17:57:46+02:00, 2013:07:31 10:06:19+02:00, 2013:07:31 10:19:13+02:00, 2013:07:31 11:22:46+02:00, 2013:07:31 13:49:58+02:00, 2013:07:31 13:50:22+02:00, 2013:08:02 10:14:43+02:00
History Software Agent          : Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5
History Changed                 : /;/metadata, /metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata
Format                          : application/pdf
Description                     : 20130802 (WER): GAT FR 050 durch 055 ersetzt (auch Weather Cover)..20130731 (WER): Anschlussbild Seite 4 geändert (Kontakt Drehkreuz), Rechtschreibfehler bei techn. Daten Seite 2, MIFARE (TM) statt (R),.FREIGABE V1.0
Doc Change Count                : 2897
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CS5.5 (7.5)
Subject                         : 20130802 (WER): GAT FR 050 durch 055 ersetzt (auch Weather Cover)..20130731 (WER): Anschlussbild Seite 4 geändert (Kontakt Drehkreuz), Rechtschreibfehler bei techn. Daten Seite 2, MIFARE (TM) statt (R),.FREIGABE V1.0
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NC4-GEA1150002A

Navigation menu