Japan Radio NKE2632 Solid State S-Band Marine Radar User Manual Installation Manual Part 7
Japan Radio Co Ltd. Solid State S-Band Marine Radar Installation Manual Part 7
Contents
- 1. Installation Manual Part 1
- 2. Installation Manual Part 2
- 3. Installation Manual Part 3
- 4. Installation Manual Part 4
- 5. Installation Manual Part 5
- 6. Installation Manual Part 6
- 7. Installation Manual Part 7
- 8. Installation Manual Part 8
- 9. Installation Manual Part 9
- 10. Installation Manual Part 10
- 11. Installation Manual Part 11
- 12. Instruction Manual Operation Part 1
- 13. Instruction Manual Operation Part 2
- 14. Instruction Manual Operation Part 3
- 15. Instruction Manual Operation Part 4
- 16. Instruction Manual Funtion Part 1
- 17. Instruction Manual Funtion Part 2
- 18. Instruction Manual Funtion Part 3
- 19. Instruction Manual Funtion Part 4
- 20. Instruction Manual Funtion Part 5
- 21. Instruction Manual Funtion Part 6
Installation Manual Part 7
5.Option Unit > 5.1 Installation of Interswitch Unit 5. Option Unit 5.1 Installation of Interswitch Unit 5.1.1 End processing of Interswitch cable(2695111153) abt. 80 mm Inner Shield Outer Shield 2695110056 2695111153 taping Width for clamping cable. abt. 30 mm abt.1000 mm Fig 5-1: Equipment cable end processing Fig 5-2: End processing of each cable core 5-1 terminal 5.Option Unit > 5.1 Installation of Interswitch Unit 5.1.2 Connection of equipment cable There is two type Interswitch(NQE-3141); NQE-3141-4A(4ch) and NQE-3141-8A(8ch). Connection Procedure 1) Ground the earth plate to the hull ground. 2) Connect the Interswitch(NQE-3141) to the Radar I/F Circuit(CQD-2273) with the 2695111153 cable. Refer to Fig 5-5: NQE-3141-4A Inter-board connection diagram. -When connect to the JAN-901/901M/701 and third-party ECDIS. Connnect the input terminal : VD, TRG, BP, BZ(JAN-901/901M/701 and third-party ECDIS) and output terminal : VDOUT, TRGOUT, BPOUT, BZOUT(NQE-3141). - When connect to the JMA-9100/7100,JMA-5300MK2, JMA-900B. Connect the VD, TRG, BP, BZ, PWR terminal on JMA-9100/7100,JMA-5300MK2, JMA-900B and VD, TRG, BP, BZ, PWR terminal on the NQE-3141. 3) Refer to End processing of Interswitch cable(2695111153) for the end of processing of Interswitch cable. When connect to the Radar I/F Circuit(CQD-2273) in the Junction box(NQE-1143), fix the cable by the metal parts that surrounded by a dotted line. Refer to the below detailed fixed position. And connect the shield of the cable to the thumbscrew or hex spacer surrounded by the circle. (Recommended crimp terminal is V5.5) Fig 5-3 Way of fixing and grounding(2695111153) When connect to the interswitch unit, fix the shield portion of the cable by the metal parts that surrounded by the dotted line. 5-2 5.Option Unit > 5.1 Installation of Interswitch Unit Fig 5-4 Cable inlet of the NQE-3141-8A So that the braided shield is not shorted to the power supply terminal block, please insulate the cable and fix with cable tie. Please put the Extra length of the cable to the bottom of the display unit so that the not shorted to the UPS or SENSOR LAN switch unit. 4) After the installation is finished, refer to the 5.1.6 Confirmation after installation and check the operation. 5-3 No.1 RADAR 5-4 Fig 5-5: NQE-3141-4A Inter-board connection diagram BRN PNK BLK ORG WHT-WHT WHT-BLU GRN YEL BLU BLK1 PNK BRN ORG BLK WHT-WHT WHT-YEL CLR PUR RED BLK2 TB911 15 14 13 12 11 10 VDIN VDINE TRGIN TRGINE BPIN BPINE BZIN BZINE MTRIN+ MTRINMTRINE PWRIN PWRINE PWROUT PWROUTE PWRIN PWRINE 14 15 WHT-WHT WHT-YEL CLR PUR RED BLK2 CH-1 PWROUT PWROUTE ISWI_BZ- 12 13 ISWI_BZ+ 10 11 ISWI_BP+ ISWI_BP- ISWI_MTR+ ISWI_MTRISWI_MTRG ISWI_TRG+ ISWI_TRG- ISWO_MTRISWO_MTRG 10 11 ISWO_BZISWO_MTR+ GRN J834 ISWI_VD+ ISWI_VD- ISWO_BPISWO_BZ+ YEL ISWO_TRGISWO_BP+ WHT-BLU WHT-WHT ISWO_TRG+ ISWO_VD+ ISWO_VD- J833 BLU BLK1 RADAR I/F Circuit CQD-2273 J833/J834 11 10 TB912 VDOUT VDOUTE TRGOUT TRGOUTE BPOUT BPOUTE BZOUT BZOUTE MTROUT+ MTROUTMTROUTE No.2 RADAR BRN PNK BLK ORG WHT-WHT WHT-BLU GRN YEL BLU BLK1 BRN BLK PNK ORG 15 14 13 12 11 10 TB913 WHT-WHT WHT-YEL CLR PUR RED BLK2 WHT-BLU WHT-WHT GRN YEL BLU BLK1 ISWO_BP+ ISWI_BZ+ ISWI_BZISWI_MTR+ ISWI_MTRISWI_MTRG PWROUT PWROUTE PWRIN PWRINE 10 11 12 13 14 15 VDIN VDINE TRGIN TRGINE BPIN BPINE BZIN BZINE MTRIN+ MTRINMTRINE PWRIN PWRINE PWROUT PWROUTE ISWI_BP+ ISWI_BP- WHT-WHT WHT-YEL CLR PUR RED BLK2 CH-2 ISWI_TRG+ ISWI_TRG- 11 10 TB914 VDOUT VDOUTE TRGOUT TRGOUTE BPOUT BPOUTE BZOUT BZOUTE MTROUT+ MTROUTMTROUTE NQE-3141-4A CCL-304R J834 ISWI_VD+ ISWI_VD- ISWO_MTRISWO_MTRG ISWO_MTR+ 10 11 ISWO_TRG+ ISWO_TRG- ISWO_BPISWO_BZ+ ISWO_BZ- ISWO_VD+ ISWO_VD- J833 RADAR I/F Circuit CQD-2273 J833/J834 No.1 ECDIS ISWO_VDISWO_TRG+ ISWO_TRGISWO_BP+ ISWO_BPISWO_BZ+ ISWO_BZISWO_MTR+ ISWO_MTRISWO_MTRG 10 11 BLU YEL ISWI_BPISWI_BZ+ ISWI_BZISWI_MTR+ ISWI_MTRISWI_MTRG PWROUT PWROUTE PWRIN PWRINE 10 11 12 13 14 15 PUR CLR BRN PNK BLK ORG WHT-WHT WHT-BLU GRN YEL BLU BLK1 PNK BRN ORG BLK H-2695111153 (JRC SUPPLY) 15 14 13 12 11 10 TB915 WHT-WHT WHT-YEL VDIN VDINE TRGIN TRGINE BPIN BPINE BZIN BZINE MTRIN+ MTRINMTRINE PWRIN PWRINE PWROUT PWROUTE ISWI_TRGISWI_BP+ WHT-WHT WHT-YEL CLR PUR RED BLK2 11 10 TB916 ISWI_VDISWI_TRG+ RED CH-3 J834 ISWI_VD+ BLK2 WHT-BLU WHT-WHT GRN J833 ISWO_VD+ BLK1 RADAR I/F Circuit CQD-2273 J833/J834 VDOUT VDOUTE TRGOUT TRGOUTE BPOUT BPOUTE BZOUT BZOUTE MTROUT+ MTROUTMTROUTE No.2 ECDIS BRN PNK BLK ORG WHT-WHT WHT-BLU GRN YEL BLU BLK1 BRN BLK PNK ORG WHT-WHT WHT-YEL CLR PUR RED BLK2 WHT-WHT WHT-BLU GRN YEL BLU BLK1 15 14 13 12 11 10 PWROUTE PWRIN PWRINE 13 14 15 WHT-WHT WHT-YEL CLR PUR RED BLK2 11 10 TB918 ISWI_MTRG PWROUT 11 12 CH-4 ISWI_BZ- ISWI_BZ+ ISWI_MTR+ ISWI_MTR- ISWI_BP+ ISWI_BP- 10 ISWI_TRG+ ISWI_TRG- J834 ISWI_VD+ ISWI_VD- ISWO_MTRISWO_MTRG ISWO_MTR+ 10 11 VDIN VDINE TRGIN TRGINE BPIN BPINE BZIN BZINE MTRIN+ MTRINMTRINE PWRIN PWRINE PWROUT PWROUTE TB917 ISWO_BP+ ISWO_BPISWO_BZ+ ISWO_BZ- ISWO_TRG+ ISWO_TRG- ISWO_VD+ ISWO_VD- J833 RADAR I/F Circuit CQD-2273 J833/J834 VDOUT VDOUTE TRGOUT TRGOUTE BPOUT BPOUTE BZOUT BZOUTE MTROUT+ MTROUTMTROUTE 5.Option Unit > 5.1 Installation of Interswitch Unit 5.1.3 NQE-3141-4A Inter-board connection diagram H-2695111153 (JRC SUPPLY) H-2695111153 (JRC SUPPLY) H-2695111153 (JRC SUPPLY) 5.Option Unit > 5.1 Installation of Interswitch Unit 5.1.4 Installation of interswitch unit Fig 5-6: Outline Drawing of NQE-3141-4A Interswitch Unit (4ch) 5-5 5.Option Unit > 5.1 Installation of Interswitch Unit Fig 5-7: Outline Drawing of NQE-3141-8A Interswitch Unit (8ch) 5-6 5.Option Unit > 5.1 Installation of Interswitch Unit 5.1.5 Settings of Interswitch Since settings have been normally made upon shipment from factory, it is advised to only confirm the settings. a. Settings of NQE-3141-4A Set dip switches SW11, SW12, and SW13 as shown below. SW12 SW11 SW13 Fig 5-8: CML-304R DIP Switch 1) SW11 setting (expansion mode, master/slave setting) Set all OFF. 5-7 5.Option Unit > 5.1 Installation of Interswitch Unit 2) SW12 setting (radar connection setting) Radar Connection Setting ON No. 1 display unit connected OFF No. 1 display unit NOT connected ON No. 1 antenna connectedd OFF No. 1 antenna NOT connected ON No. 2 display unit connected OFF No. 2 display unit NOT connected ON No. 2 antenna connected OFF No. 2 antenna NOT connected ON No. 3 display unit connected OFF No. 3 display unit NOT connected ON No. 3 antenna connected OFF No. 3 antenna NOT connected ON No. 4 display unit connected OFF No. 4 display unit NOT connected ON No. 4 antenna connected OFF No. 4 antenna NOT connected 3) SW13 (unused) Set all OFF. 5-8 5.Option Unit > 5.1 Installation of Interswitch Unit b. Settings of NQE-3141-8A The internal structure of NQE-3141-8A includes two units of CCL-304R in the two-storied structure. Fig 5-9: NQE-3141-8A internal structure Fig 5-10: Access to Lower Board of NQE-3141-8A 5-9 5.Option Unit > 5.1 Installation of Interswitch Unit • Although dip switches settings are basically the same as the settings shown in Access, it is necessary to make settings for each of the two SW12. • It is necessary to remove six screws marked in the above drawing in order to access the first story portion. • • • • With regard to SW12 board located at the upper position, make settings for CH1 to CH4. With regard to SW12 board located at the lower position, make settings for CH5 to CH8. CH1 to CH4 displayed on the terminal block mean CH5 to CH8. Settings have been made for SW11 and SW13 upon shipment. Do not change those settings. Factory default setting (bit1-bit2-bit3-bit4) SW11-upper OFF-OFF-OFF-ON SW11-lower OFF-OFF-ON-ON SW13-both OFF-OFF-OFF-OFF 5-10 5.Option Unit > 5.1 Installation of Interswitch Unit • Settings of upper CCL-304R, SW12 (radar connection setting) ON No. 1 display unit connected OFF No. 1 display unit NOT connected ON No. 1 antenna connected OFF No. 1 antenna NOT connected ON No. 2 display unit connected OFF No. 2 display unit NOT connected ON No. 2 antenna connected OFF No. 2 antenna NOT connected ON No. 3 display unit connected OFF No. 3 display unit NOT connected ON No. 3 antenna connected OFF No. 3 antenna NOT connected ON No. 4 display unit connected OFF No. 4 display unit NOT connected ON No. 4 antenna connected OFF No. 4 antenna NOT connected 5-11 5.Option Unit > 5.1 Installation of Interswitch Unit • Setting of lower CCL-304R, SW12 (radar connection setting) 5.1.6 ON No. 5 display unit connected OFF No. 5 display unit NOT connected ON No. 5 antenna connected OFF No. 5 antenna NOT connected ON No. 6 display unit connected OFF No. 6 display unit NOT connected ON No. 6 antenna connected OFF No. 6 antenna NOT connected ON No. 7 display unit connected OFF No. 7 display unit NOT connected ON No. 7 antenna connected OFF No. 7antenna NOT connected ON No. 8 display unit connected OFF No. 8 display unit NOT connected ON No. 8 antenna connected OFF No. 8 antenna NOT connected Confirmation after installation 1) After having checked connections, turn on the switchboard breaker. 2) Turn on the power to the radar display unit, and make sure that the interswitch button is displayed on the screen and pressing the button will switch antennas. 3) When a system consists of two devices, make sure that both left and right radars conform to the screen indication. 4) When a system consists of three devices, make sure that the CH number and the display unit position are arranged as intended. 5-12 5.Option Unit > 5.2 Installation of Power Control Unit 5.2 Installation of Power Control Unit Power control unit NQE-3167 is used when an antenna and a transmitter-receiver are installed at a location away from the bridge, such as a foremast. In the case of a two-unit type antenna, the maximum length of the cable that connects between the display unit and the antenna is 65 meters. In the case of a three-unit type antenna, the maximum length of the cable that connects between the display unit and the transmitter-receiver is 35 meters. By using NQE-3167 power control unit, the maximum length of the cable that connects between the display unit and the antenna (transmitter-receiver) can be extended up to 465 meters. Maximum length of the cable connecting between the antenna and the transmitter-receiver 30m Maximum length of the cable connecting between the transmitter-receiver and the PCU (NQE-3167) 35m Maximum length of the cable connecting between the display unit and the PCU (NQE-3167) 400m 5.2.1 Connection with NKE-2103 type and NKE-2254-6HS type scanner units Use 19-core composite cable CFQ-6912-** for the installation of those types of antennas (Asterisks ** use the cable length, and the available cable length is 5, 10, 20, 30, 40, 50, and 65) The display-unit side end of this cable is a metal shell round connector. (See 2.1.1CFQ-6912-** ) Connect that cable to J2 of the power control unit. If the metal shell round connector is cut, connect the cable to TB3 located in the power control unit. For procedures for processing the cable end, see Section 2.1.4 Cable end processing method. With regard to six devices, such as MOTOR+ (2P), MOTOR-(2P), 1A (+48V), and 2A (48VG), two AWG16 cables must be connected to one terminal block. As necessary, use a bar-mould crimp-type terminal or the like. (See Fig 5-11: Connection of CFQ-6912) The connection between scanner unit and AC/DC converter NBA-5135 is not necessary. Instead, power control unit NQE-3167 supplies DC power. 5-13 5.Option Unit > 5.2 Installation of Power Control Unit Fig 5-11: Connection of CFQ-6912 5-14 5.Option Unit > 5.2 Installation of Power Control Unit 5.2.2 Connections to NKE-1125, NTG-3225, NKE-1130, NTG-3230, NKE-1632 and NKE-2632 Use 14-core composite cable 2695110056 for the installation of those types of antennas. For the procedures for processing the cable end, see Fig 5-12: Equipment cable end processing. For the wiring procedures, see 5.2.7 Inter –board connection diagram of power control unit. 5.2.3 End processing of 2695110056 cable abt. 80 mm Inner Shield terminal Outer Shield 2695110056 2695111153 taping Width for clamping cable. abt. 30 mm abt.1000 mm Fig 5-12: Equipment cable end processing 5.2.4 End processing of each cable core Fig 5-13: End processing of each cable core 5.2.5 Connection to display unit Use 14-core composite cable 2695110056 and coaxial cable RG-10/UY to connect power control unit NQE-3167 to each display unit. Among the two cables, use coaxial cable RG-10/UY to connect the radar video signal. For the procedures for processing the cable end and the wiring procedures, see Fig 5-12: Equipment cable end processing. For the wiring procedures, see 5.2.7 Inter –board connection diagram of power control unit. 5-15 5.Option Unit > 5.2 Installation of Power Control Unit 5.2.6 Outline Drawing of NQE-3167 Power Control Unit Fig 5-14: Outline Drawing of NQE-3167 Power Control Unit 5-16 5.Option Unit > 5.2 Installation of Power Control Unit J2 EARTH PLATE Fig 5-15: NQE-3167 cable entrance Fig 5-16: NQE-3167 terminal block Securely ground the included earth plate to the hull's earth. 5-17 5.Option Unit > 5.2 Installation of Power Control Unit 5.2.7 Inter –board connection diagram of power control unit 5.2.7.1 Inter-board connection diagram of JMR-9230-S3, JMR-7230-S3 5-18 5.Option Unit > 5.2 Installation of Power Control Unit 5.2.7.2 Inter-board connection diagram of JMR-9230-S, JMR-7230-S 5-19 5.Option Unit > 5.2 Installation of Power Control Unit 5.2.7.3 Inter-board connection diagram of JMR-9272-S, JMR-7272-S J2 5-20 5.Option Unit > 5.2 Installation of Power Control Unit 5.2.7.4 Inter-board connection diagram of JMR-9282-S/SH, JMR-7282-S/SH J2 5-21 5.Option Unit > 5.2 Installation of Power Control Unit 5.2.7.5 Inter-board connection diagram of JMR-9225-7X3/9X3, JMR-7225-7X3/9X3 J2 5-22 5.Option Unit > 5.2 Installation of Power Control Unit 5.2.7.6 Inter-board connection diagram of JMR-9225-6X/9X, JMR-7225-6X/9X 5-23 0.6/1kV-DPYCY-6 5-24 TB838 TB840 J832 VD+ VDTRIG+ TRIGBP+ BPBZ+ BZMTR+ MTRMTRG (N.C.) DC+ DC- 10 11 12 13 14 WHT ORN BLU RED NO CONNECTION NO CONNECTION WHT ORN 10 11 12 13 14 15 16 J831 RIF J839 DC_SC_IN J837 AC_SC_IN JUNCTION BOX NQE-1143 400m MAX CQD-2273 Radar Interface Circuit RG-10/UY COAXIAL CABLE for VIDEO (JRC SUPPLY) H-2695110056 400m MAX 14-CORES COMPOSITE CABLE (JRC SUPPLY) AC100-115V/AC220-240V 50/60Hz 1φ SHIP’S MAINS FARM+ FARMVD+ VD- TB1 UIN VIN WIN UHIN VHIN UHOUT VHOUT UOUT VOUT WOUT TB3 MT+ MTMTE VD VDE 2TRG 2TGE 2BP+ 2BP2BZ+ 2BZGND 1A 2A M+ M+ MM- 0.6/1kV-DPYCYS-1.5 AC100V,1φ,100W 10 11 12 13 14 15 16 17 18 To CCU CML-836-DC W841:7ZCNA4164 To PSU W853:7ZCNA4160 NO CONNECTION +48V/TRX+ 48VG/TRXHT HTR IS ISR TB2 TRG+ TRGBP+ BPBZ+ BZMTR+ MTRMTRE POWER CONTROL UNIT NQE-3167 STEP-DOWN TRANSFORMER NBL-175 MTR- WHT TB105 UTH BZE BZ BLK BPE BP TIYE TIY J1 1A 2A J3 GRN ORN YEL.T/PNK.T BLK.T/SKY.T P82 LVR PMS P81 PTI PTE TXI TXE NJU-85 P2 LVR PMS P1 PTI PTE TXI TXE PERFORMANCE MONITOR BLK RED BLU BRN WHT (X-BAND 25kW RADAR) BLK RED BLU BRN WHT Wiring of PERFORMANCE MONITOR is completed. JMR-9225-6XH,JMR-7225-6XHレーダー パワーコントロールユニット間 盤間接続図 AC220V, 50/60Hz, 1φ,for HEATER SHIP’S MAINS MTR+ VDE VD J2 1A 2A J5 1A 2A YEL RED.T/GRN.T PUR.T/BRN.T WHT.T/ORN.T BLU.T/GRY.T J4 INTERCONNECTION DIAGRAM OF BETWEEN RADAR TYPE JMR-9225-6XH/JMR-7225-6XH and NQE-3167 POWER CONTROL UNIT 0.6/1kV-DPYCYS-1.5 0.6/1kV-DPYCYS-1.5 CIRCUIT BREAKER 5A (SHIP YARD SUPPLY) “D” HEATER OPTION 19-CORES COMPOSITE CABLE (JRC SUPPLY) CFQ-6912-** 0.6/1kV-DPYCYS-1.5 SCANNER UNIT NKE-2254-6HS 5.Option Unit > 5.2 Installation of Power Control Unit 5.2.7.7 Inter-board connection diagram of JMR-9225-6XH, JMR-7225-6XH 5.Option Unit > 5.2 Installation of Power Control Unit 5.2.7.8 Inter-board connection diagram of JMR-9210-6X/6XH, JMR-7210-6X/6XH 5-25 5.Option Unit> 5.3 Connection of VDR 5.3 Connection of VDR 5.3.1 Connection with LAN (IEC61162-450) When the VDR have LAN port, use connection with the LAN (IEC61162-450). There is the LAN port J4122 which is located in central control unit (NDC-1590). See the drawing below. Fig 5-17 VDR connection connector LAN(IEC61162-450) After the connection, please set the display unit refers to the 4.15 Setting of VDR. 5.3.2 Connection with Analog RGB When the VDR does not have LAN port, use connection with Analog RGB. Analog RGB signal for VDR is output from J4205 which is located in the central control unit (NDC-1590). See the drawing below. Fig 5-18: VDR connection connector Analog RGB 5-26 5.Option Unit> 5.4 Printer 5.3.2.1 VDR I/F kit The VDR I/F kit is used to connection with analog RGB. VDR I/F kit CQD-1891 includes: DSUB15P - BNC cable (KB5BNC2K, 2 meters) 1 pcs BNC to BNC adapter (BNC-A-JJ) 5 pcs BNC connector (3CV-P2) 5 pcs 5 piece Use 3C-2V coaxial cable for connection. RED KB-5BNC2K NDC-1590 J4205 BNC BNC-A-JJ 3CV-P2 3C-2V BNC BNC-A-JJ 3CV-P2 3C-2V BNC BNC-A-JJ 3CV-P2 3C-2V BNC BNC-A-JJ 3CV-P2 3C-2V BNC BNC-A-JJ 3CV-P2 GRN BLU RED GRN BLU GRY BLK :red :green :blue :HSYNC :VSYNC GRY BLK CQD-1891 Fig 5-19: CQD-1891 VDR I/F Kit 5-27 3C-2V TO VDR 5.Option Unit> 5.4 Printer 5.4 Printer Set the printer accoding to the following procedures. When there is no keyboard operating unit, prepare the keyboard of a USB interface. There is a procedure that cannot be set for the keyboard not to exist. 5.4.1 Printer Composition Externals of the printer are as follows. ●Necessary for setting No 名称 Start Poster AC Adaptor CD for Printer Driver Two sided of automatic operation print accessories Ink Printer Head Print Paper USB Keyboard 備考 When NCE-5625 Keyboard Operation Unit is not equipped. ●Not necessary for setting No 名称 LAN Cable USB Cable Warranty Card Directions of print paper Support documentation 備考 It doesn't use. Use the specified LAN cable. It doesn't use. Please keep it with the ship importantly. Please keep it with the ship importantly. Please keep it with the ship importantly. 5-28 5.Option Unit> 5.4 Printer 5.4.2 Printer Assembly Assemble a printer according to the following procedures. ① Set up the printer according to attached “Start” poster. ② Set some papers and push the power button. Power button 5-29 5.Option Unit> 5.4 Printer 5.4.3 Setting Printer The setting method of the printer is described. Set the printer according to the following procedures. 5.4.3.1 Connecting Power Cable and Printer LAN Cable Connect power cable and printer LAN cable with the printer and main hub unit respectively. Connecting location is described to “Start” poster. Connecting location of power cable Connecting location of LAN cable 5.4.3.2 Confirming Printer IP Address Confirm IP address of the printer according to the following procedures. 1. Power on Printer and ECDIS. 2. Keep pressing “Resume” button and “Wireless” button (see below diagram) at the same time. Confirm that 2 pieces of paper ” HP Network Configuration Page” are printed. “Resume” but- “Wireless” button 5-30 5.Option Unit> 5.4 Printer 3. Confirm default ”IP Address” and ”Subnet Mask” on the “HP Network Configuration Page”. ex) IP Address Subnet Mask Default ”IP Address” and ”Subnet Mask” 5.4.3.3 Setting Printer IP Address Set up the IP address of the printer according to the following procedures. 1. Power on this equipment. 2. After the default task starts, click the [Menu] button of the “Left Tool Bar”. The “Menu” dialog is displayed. 5-31 5.Option Unit> 5.4 Printer 3. Click [Code Input] button. The “Password” dialog is displayed. 4. After the password "0009" is input with the software keyboard, click the [Enter] button. The [service] button is added to the menu. Once the [Service] button is added, it will be displayed until the task menu is finished. 5. Click the [Service] button of the “Menu” dialog. The sub menu of [Service] is displayed. 6. Click the [Installation] button. The “Installation” dialog is displayed. 5-32 5.Option Unit> 5.4 Printer 7. [System Configuration] is chosen by the first classification pane, and [Network] is chosen by the second classification pane. The “Network” dialog is displayed on the edit pane. Make a note of the present IP address. Make a note of the IP address. 8. According to the following explanation, input the IP address of "Own Task Station" and click the [Set] button. Click after input 1st to 3rd octet Input the default IP address of the printer. 4th octet Input a different value from the default IP address of the printer. 9. Click the [Code Input] button of the “Menu” dialog. And after the password "9999" is input with the software keyboard, click the [Enter] button. The task is finished and it returns to the task menu screen. 5-33 5.Option Unit> 5.4 Printer 10. Input the password "0913" into the “Code input” box of the task menu screen. The “Internet Explore” is displayed. 11. Input [http://IP address of printer] into the address bar. “HP Officejet Pro 8100 N811a” page is displayed. 5-34 5.Option Unit> 5.4 Printer Note: When following error is displayed, delete “Temporary Internet files” as follows. 1) Start Internet explorer again. Select "Tools" - “Internet Options…" 1) Select "Tools". 2) Select “Internet Options…". 2) “Internet Options" dialog is displayed. Click [Delete...] button. Click [Delete...] button 5-35 5.Option Unit> 5.4 Printer 3) “Delete Browsing History” dialog is displayed. Check “Temporary Internet Files” and click [Delete] button. 1) Check "Temporary Internet files" 2) Click [Delete] button 12. Click [Network] and select ”IPv4”of ”Wired (802.3)”. 1) Click ”Network” tab 2) Select ”IPv4” Enter “Manual IP Address”, ”Manual Subnet Mask” and “Manual Default Gatebutton. way” according to bellow diagram. After enter the value, click 13. 5-36 5.Option Unit> 5.4 Printer IP Address Subnet Mask Default Gateway 14. No.1 Printer No.2 Printer 172.16.60.181 172.16.60.182 255.255.0.0 255.255.0.0 172.16.60.225 172.16.60.225 After setup, close the "Internet Explore" and start a task. 15. Return the IP address of this equipment to the original value according to the procedure of 8. 16. The IP address assigned for the printer setup is added to Network List of the Network dialog. Check the line of relevance and click the [Delete] button. 1) Check 2) Click [Delete]button 5-37 5.Option Unit> 5.4 Printer 5.4.4 Equipment setup The existence of a printer is set up by equipment setup of a subsystem. Change the equipment setup of the subsystem in the “Subsystem Installation” dialog. Note: Refer to 4.4 "Subsystem Installation". 1. Click the [Menu] button of the “Left Tool Bar”. The “Menu” dialog is displayed. 2. Click [Code Input] button. The “Password” dialog is displayed. 3. After the password "0009" is input with the software keyboard, click the [Enter] button. The [service] button is added to the menu. Once the [Service] button is added, it will be displayed until the task menu is finished. 4. Click the [Service] button of the “Menu” dialog. The sub menu of [Service] is displayed. 5. Click the [Installation] button. The “Installation” dialog is displayed. 6. [System Configuration] is chosen by the first classification pane, and [Subsystem Installation] is chosen by the second classification pane. The “Subsystem Installation” dialog is displayed on the edit pane. 5-38 5.Option Unit> 5.4 Printer 7. Check [Printer] in "Device Installation" and click the [Set] button. 1) Check 2) Click [Set]button 5-39 5.Option Unit> 5.4 Printer 5.4.5 Confirming Printing Operation Confirm the printer prints normally on the sheet according to the following procedures. Since there is no print function in "Conning Display", it cannot confirm in "Conning Display". 1. Click the [Print] button of “Left Tool Bar”. Click [Print] button 2. Confirm a screen image on display is printed. When the image cannot printed Set the printer port refer to the following steps. In this steps need the keyboard. When there is no keyboard operating unit, prepare the keyboard of a USB interface. 1. Input the password [9999], and click the [Enter]. Task manager will open. Input the password [9999] and click the [Enter]. 5-40 5.Option Unit> 5.4 Printer 2. Select the [File]-[New Task(Run…)]. Select the [New Task(Run…)]. 3. Following dialog opens. Input the [explorer] and click the [OK] button. 1)Input the [Explorer]. 2)Click the 「OK」 button. 4. Click the [Open Control Panel] from the open explorer. Click the [Open Control Panel]. 5-41 5.Option Unit> 5.4 Printer 5. Click the [Devices and Printers] from [Control Panel]. Click the [Devices and Printers]. 6. Right-click the [HP Officejet Pro 8100(Network)] and select the [Printer properties]. 1)Right click the [HP Officejet Pro 8100(Network]. 2)select the [Printer properties]. 7. Click the [Add Port] button from[Ports] tab. 1)Click the [Ports] tab. 2)Click the [Add Port...]. 5-42 5.Option Unit> 5.4 Printer 8. Select the [Standard TCP/IP Port] and click the [New Port…] button. 1)Click the [Standard TCP/IP Port] tab. 2)Click the [New Port...] button. 9. Following dialog opens. Check the printer is connected to the network and turned on. After checking, click the [Next] button. Click the [Next] button. 5-43 5.Option Unit> 5.4 Printer 10. Input the No.1 Printer IP address-[172.16.60.181] and click the [Next] button. When set the No.2 Printer, input the IP address [172.16.60.182]. 1)Input the IP address. 2)Click the [Next] button. 11. Click the [Finish] button. 1)Click the [Finish] button. Setting of the printer port is end. Restart the display unit, and confirm a screen image on display is printed. Refer to the 5.4.5 Confirming Printing Operation. 12. Set the other display unit about the printer port By the same procedure(When the image cannot print 1-11). Setting of the printer port is end above. 5-44
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : admin Create Date : 2015:10:15 15:07:39-07:00 Modify Date : 2015:10:15 15:07:46-07:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2015:10:15 15:07:46-07:00 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Creator : admin Document ID : uuid:4dd565bd-6bc6-4a87-9513-df0389c232c0 Instance ID : uuid:a10fad07-3a9b-4aa9-ae15-a4622d366f4d Producer : iTextSharp™ 5.5.0 ©2000-2013 iText Group NV (AGPL-version); modified using iTextSharp™ 5.5.0 ©2000-2013 iText Group NV (AGPL-version) Page Count : 44EXIF Metadata provided by EXIF.tools