Japan Radio NKE2632 Solid State S-Band Marine Radar User Manual Installation Manual Part 7

Japan Radio Co Ltd. Solid State S-Band Marine Radar Installation Manual Part 7

Installation Manual Part 7

Download: Japan Radio NKE2632 Solid State S-Band Marine Radar User Manual Installation Manual Part 7
Mirror Download [FCC.gov]Japan Radio NKE2632 Solid State S-Band Marine Radar User Manual Installation Manual Part 7
Document ID2791040
Application IDo6LERARSP56i/cSy+lEJSg==
Document DescriptionInstallation Manual Part 7
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize302.43kB (3780329 bits)
Date Submitted2015-10-22 00:00:00
Date Available2015-10-22 00:00:00
Creation Date2015-10-15 15:07:39
Producing SoftwareiTextSharp™ 5.5.0 ©2000-2013 iText Group NV (AGPL-version); modified using iTextSharp™ 5.5.0 ©2000-2013 iText Group NV (AGPL-version)
Document Lastmod2015-10-15 15:07:46
Document TitleInstallation Manual Part 7
Document CreatorPScript5.dll Version 5.2.2
Document Author: admin

5.Option Unit > 5.1 Installation of Interswitch Unit
5. Option Unit
5.1 Installation of Interswitch Unit
5.1.1 End processing of Interswitch cable(2695111153)
abt. 80 mm
Inner Shield
Outer Shield
2695110056
2695111153
taping
Width for
clamping cable.
abt. 30 mm
abt.1000 mm
Fig 5-1: Equipment cable end processing
Fig 5-2: End processing of each cable core
5-1
terminal
5.Option Unit > 5.1 Installation of Interswitch Unit
5.1.2
Connection of equipment cable
There is two type Interswitch(NQE-3141); NQE-3141-4A(4ch) and NQE-3141-8A(8ch).
Connection Procedure
1)
Ground the earth plate to the hull ground.
2)
Connect the Interswitch(NQE-3141) to the Radar I/F Circuit(CQD-2273) with the
2695111153 cable. Refer to Fig 5-5: NQE-3141-4A Inter-board connection diagram.
-When connect to the JAN-901/901M/701 and third-party ECDIS.
Connnect the input terminal : VD, TRG, BP, BZ(JAN-901/901M/701 and third-party ECDIS)
and output terminal : VDOUT, TRGOUT, BPOUT, BZOUT(NQE-3141).
- When connect to the JMA-9100/7100,JMA-5300MK2, JMA-900B.
Connect the VD, TRG, BP, BZ, PWR terminal on JMA-9100/7100,JMA-5300MK2,
JMA-900B and VD, TRG, BP, BZ, PWR terminal on the NQE-3141.
3)
Refer to End processing of Interswitch cable(2695111153) for the end of processing of
Interswitch cable. When connect to the Radar I/F Circuit(CQD-2273) in the Junction
box(NQE-1143), fix the cable by the metal parts that surrounded by a dotted line.
Refer to the below detailed fixed position. And connect the shield of the cable to the
thumbscrew or hex spacer surrounded by the circle. (Recommended crimp terminal is V5.5)
Fig 5-3 Way of fixing and grounding(2695111153)
When connect to the interswitch unit, fix the shield portion of the cable by the metal parts
that surrounded by the dotted line.
5-2
5.Option Unit > 5.1 Installation of Interswitch Unit
Fig 5-4 Cable inlet of the NQE-3141-8A
So that the braided shield is not shorted to the power supply terminal block, please
insulate the cable and fix with cable tie. Please put the Extra length of the cable to the
bottom of the display unit so that the not shorted to the UPS or SENSOR LAN switch
unit.
4) After the installation is finished, refer to the 5.1.6 Confirmation after installation and
check the operation.
5-3
No.1 RADAR
5-4
Fig 5-5: NQE-3141-4A Inter-board connection diagram
BRN
PNK
BLK
ORG
WHT-WHT
WHT-BLU
GRN
YEL
BLU
BLK1
PNK
BRN
ORG
BLK
WHT-WHT
WHT-YEL
CLR
PUR
RED
BLK2
TB911
15
14
13
12
11
10
VDIN
VDINE
TRGIN
TRGINE
BPIN
BPINE
BZIN
BZINE
MTRIN+
MTRINMTRINE
PWRIN
PWRINE
PWROUT
PWROUTE
PWRIN
PWRINE
14
15
WHT-WHT
WHT-YEL
CLR
PUR
RED
BLK2
CH-1
PWROUT
PWROUTE
ISWI_BZ-
12
13
ISWI_BZ+
10
11
ISWI_BP+
ISWI_BP-
ISWI_MTR+
ISWI_MTRISWI_MTRG
ISWI_TRG+
ISWI_TRG-
ISWO_MTRISWO_MTRG
10
11
ISWO_BZISWO_MTR+
GRN
J834
ISWI_VD+
ISWI_VD-
ISWO_BPISWO_BZ+
YEL
ISWO_TRGISWO_BP+
WHT-BLU
WHT-WHT
ISWO_TRG+
ISWO_VD+
ISWO_VD-
J833
BLU
BLK1
RADAR I/F Circuit CQD-2273
J833/J834
11
10
TB912
VDOUT
VDOUTE
TRGOUT
TRGOUTE
BPOUT
BPOUTE
BZOUT
BZOUTE
MTROUT+
MTROUTMTROUTE
No.2 RADAR
BRN
PNK
BLK
ORG
WHT-WHT
WHT-BLU
GRN
YEL
BLU
BLK1
BRN
BLK
PNK
ORG
15
14
13
12
11
10
TB913
WHT-WHT
WHT-YEL
CLR
PUR
RED
BLK2
WHT-BLU
WHT-WHT
GRN
YEL
BLU
BLK1
ISWO_BP+
ISWI_BZ+
ISWI_BZISWI_MTR+
ISWI_MTRISWI_MTRG
PWROUT
PWROUTE
PWRIN
PWRINE
10
11
12
13
14
15
VDIN
VDINE
TRGIN
TRGINE
BPIN
BPINE
BZIN
BZINE
MTRIN+
MTRINMTRINE
PWRIN
PWRINE
PWROUT
PWROUTE
ISWI_BP+
ISWI_BP-
WHT-WHT
WHT-YEL
CLR
PUR
RED
BLK2
CH-2
ISWI_TRG+
ISWI_TRG-
11
10
TB914
VDOUT
VDOUTE
TRGOUT
TRGOUTE
BPOUT
BPOUTE
BZOUT
BZOUTE
MTROUT+
MTROUTMTROUTE
NQE-3141-4A
CCL-304R
J834
ISWI_VD+
ISWI_VD-
ISWO_MTRISWO_MTRG
ISWO_MTR+
10
11
ISWO_TRG+
ISWO_TRG-
ISWO_BPISWO_BZ+
ISWO_BZ-
ISWO_VD+
ISWO_VD-
J833
RADAR I/F Circuit CQD-2273
J833/J834
No.1 ECDIS
ISWO_VDISWO_TRG+
ISWO_TRGISWO_BP+
ISWO_BPISWO_BZ+
ISWO_BZISWO_MTR+
ISWO_MTRISWO_MTRG
10
11
BLU
YEL
ISWI_BPISWI_BZ+
ISWI_BZISWI_MTR+
ISWI_MTRISWI_MTRG
PWROUT
PWROUTE
PWRIN
PWRINE
10
11
12
13
14
15
PUR
CLR
BRN
PNK
BLK
ORG
WHT-WHT
WHT-BLU
GRN
YEL
BLU
BLK1
PNK
BRN
ORG
BLK
H-2695111153 (JRC SUPPLY)
15
14
13
12
11
10
TB915
WHT-WHT
WHT-YEL
VDIN
VDINE
TRGIN
TRGINE
BPIN
BPINE
BZIN
BZINE
MTRIN+
MTRINMTRINE
PWRIN
PWRINE
PWROUT
PWROUTE
ISWI_TRGISWI_BP+
WHT-WHT
WHT-YEL
CLR
PUR
RED
BLK2
11
10
TB916
ISWI_VDISWI_TRG+
RED
CH-3
J834
ISWI_VD+
BLK2
WHT-BLU
WHT-WHT
GRN
J833
ISWO_VD+
BLK1
RADAR I/F Circuit CQD-2273
J833/J834
VDOUT
VDOUTE
TRGOUT
TRGOUTE
BPOUT
BPOUTE
BZOUT
BZOUTE
MTROUT+
MTROUTMTROUTE
No.2 ECDIS
BRN
PNK
BLK
ORG
WHT-WHT
WHT-BLU
GRN
YEL
BLU
BLK1
BRN
BLK
PNK
ORG
WHT-WHT
WHT-YEL
CLR
PUR
RED
BLK2
WHT-WHT
WHT-BLU
GRN
YEL
BLU
BLK1
15
14
13
12
11
10
PWROUTE
PWRIN
PWRINE
13
14
15
WHT-WHT
WHT-YEL
CLR
PUR
RED
BLK2
11
10
TB918
ISWI_MTRG
PWROUT
11
12
CH-4
ISWI_BZ-
ISWI_BZ+
ISWI_MTR+
ISWI_MTR-
ISWI_BP+
ISWI_BP-
10
ISWI_TRG+
ISWI_TRG-
J834
ISWI_VD+
ISWI_VD-
ISWO_MTRISWO_MTRG
ISWO_MTR+
10
11
VDIN
VDINE
TRGIN
TRGINE
BPIN
BPINE
BZIN
BZINE
MTRIN+
MTRINMTRINE
PWRIN
PWRINE
PWROUT
PWROUTE
TB917
ISWO_BP+
ISWO_BPISWO_BZ+
ISWO_BZ-
ISWO_TRG+
ISWO_TRG-
ISWO_VD+
ISWO_VD-
J833
RADAR I/F Circuit CQD-2273
J833/J834
VDOUT
VDOUTE
TRGOUT
TRGOUTE
BPOUT
BPOUTE
BZOUT
BZOUTE
MTROUT+
MTROUTMTROUTE
5.Option Unit > 5.1 Installation of Interswitch Unit
5.1.3 NQE-3141-4A Inter-board connection diagram
H-2695111153 (JRC SUPPLY)
H-2695111153 (JRC SUPPLY)
H-2695111153 (JRC SUPPLY)
5.Option Unit > 5.1 Installation of Interswitch Unit
5.1.4 Installation of interswitch unit
Fig 5-6: Outline Drawing of NQE-3141-4A Interswitch Unit (4ch)
5-5
5.Option Unit > 5.1 Installation of Interswitch Unit
Fig 5-7: Outline Drawing of NQE-3141-8A Interswitch Unit (8ch)
5-6
5.Option Unit > 5.1 Installation of Interswitch Unit
5.1.5 Settings of Interswitch
Since settings have been normally made upon shipment from factory, it is
advised to only confirm the settings.
a. Settings of NQE-3141-4A
Set dip switches SW11, SW12, and SW13 as shown below.
SW12
SW11
SW13
Fig 5-8: CML-304R DIP Switch
1)
SW11 setting (expansion mode, master/slave setting)
Set all OFF.
5-7
5.Option Unit > 5.1 Installation of Interswitch Unit
2)
SW12 setting (radar connection setting)
Radar Connection Setting
ON
No. 1 display unit connected
OFF
No. 1 display unit NOT connected
ON
No. 1 antenna connectedd
OFF
No. 1 antenna NOT connected
ON
No. 2 display unit connected
OFF
No. 2 display unit NOT connected
ON
No. 2 antenna connected
OFF
No. 2 antenna NOT connected
ON
No. 3 display unit connected
OFF
No. 3 display unit NOT connected
ON
No. 3 antenna connected
OFF
No. 3 antenna NOT connected
ON
No. 4 display unit connected
OFF
No. 4 display unit NOT connected
ON
No. 4 antenna connected
OFF
No. 4 antenna NOT connected
3) SW13 (unused)
Set all OFF.
5-8
5.Option Unit > 5.1 Installation of Interswitch Unit
b. Settings of NQE-3141-8A
The internal structure of NQE-3141-8A includes two units of CCL-304R in the two-storied
structure.
Fig 5-9: NQE-3141-8A internal structure
Fig 5-10: Access to Lower Board of NQE-3141-8A
5-9
5.Option Unit > 5.1 Installation of Interswitch Unit
• Although dip switches settings are basically the same as the settings shown in Access, it is
necessary to make settings for each of the two SW12.
• It is necessary to remove six screws marked in the above drawing in order to access the first
story portion.
•
•
•
•
With regard to SW12 board located at the upper position, make settings for CH1 to CH4.
With regard to SW12 board located at the lower position, make settings for CH5 to CH8.
CH1 to CH4 displayed on the terminal block mean CH5 to CH8.
Settings have been made for SW11 and SW13 upon shipment. Do not change those
settings.
Factory default setting (bit1-bit2-bit3-bit4)
SW11-upper
OFF-OFF-OFF-ON
SW11-lower
OFF-OFF-ON-ON
SW13-both
OFF-OFF-OFF-OFF
5-10
5.Option Unit > 5.1 Installation of Interswitch Unit
• Settings of upper CCL-304R, SW12 (radar connection setting)
ON
No. 1 display unit connected
OFF
No. 1 display unit NOT connected
ON
No. 1 antenna connected
OFF
No. 1 antenna NOT connected
ON
No. 2 display unit connected
OFF
No. 2 display unit NOT connected
ON
No. 2 antenna connected
OFF
No. 2 antenna NOT connected
ON
No. 3 display unit connected
OFF
No. 3 display unit NOT connected
ON
No. 3 antenna connected
OFF
No. 3 antenna NOT connected
ON
No. 4 display unit connected
OFF
No. 4 display unit NOT connected
ON
No. 4 antenna connected
OFF
No. 4 antenna NOT connected
5-11
5.Option Unit > 5.1 Installation of Interswitch Unit
• Setting of lower CCL-304R, SW12 (radar connection setting)
5.1.6
ON
No. 5 display unit connected
OFF
No. 5 display unit NOT connected
ON
No. 5 antenna connected
OFF
No. 5 antenna NOT connected
ON
No. 6 display unit connected
OFF
No. 6 display unit NOT connected
ON
No. 6 antenna connected
OFF
No. 6 antenna NOT connected
ON
No. 7 display unit connected
OFF
No. 7 display unit NOT connected
ON
No. 7 antenna connected
OFF
No. 7antenna NOT connected
ON
No. 8 display unit connected
OFF
No. 8 display unit NOT connected
ON
No. 8 antenna connected
OFF
No. 8 antenna NOT connected
Confirmation after installation
1)
After having checked connections, turn on the switchboard breaker.
2)
Turn on the power to the radar display unit, and make sure that the interswitch button is
displayed on the screen and pressing the button will switch antennas.
3)
When a system consists of two devices, make sure that both left and right radars conform to
the screen indication.
4)
When a system consists of three devices, make sure that the CH number and the display
unit position are arranged as intended.
5-12
5.Option Unit > 5.2 Installation of Power Control Unit
5.2 Installation of Power Control Unit
Power control unit NQE-3167 is used when an antenna and a transmitter-receiver are installed at
a location away from the bridge, such as a foremast.
In the case of a two-unit type antenna, the maximum length of the cable that connects between
the display unit and the antenna is 65 meters. In the case of a three-unit type antenna, the
maximum length of the cable that connects between the display unit and the transmitter-receiver
is 35 meters.
By using NQE-3167 power control unit, the maximum length of the cable that connects between
the display unit and the antenna (transmitter-receiver) can be extended up to 465 meters.
Maximum length of the cable connecting between the
antenna and the transmitter-receiver
30m
Maximum length of the cable connecting between the
transmitter-receiver and the PCU (NQE-3167)
35m
Maximum length of the cable connecting between the
display unit and the PCU (NQE-3167)
400m
5.2.1 Connection with NKE-2103 type and NKE-2254-6HS type scanner units
Use 19-core composite cable CFQ-6912-** for the installation of those types of antennas
(Asterisks ** use the cable length, and the available cable length is 5, 10, 20, 30, 40, 50, and 65)
The display-unit side end of this cable is a metal shell round connector. (See 2.1.1CFQ-6912-** )
Connect that cable to J2 of the power control unit.
If the metal shell round connector is cut, connect the cable to TB3 located in the power control
unit. For procedures for processing the cable end, see Section 2.1.4 Cable end processing
method.
With regard to six devices, such as MOTOR+ (2P), MOTOR-(2P), 1A (+48V), and 2A (48VG),
two AWG16 cables must be connected to one terminal block. As necessary, use a bar-mould
crimp-type terminal or the like. (See Fig 5-11: Connection of CFQ-6912)
The connection between scanner unit and AC/DC converter NBA-5135 is not necessary.
Instead, power control unit NQE-3167 supplies DC power.
5-13
5.Option Unit > 5.2 Installation of Power Control Unit
Fig 5-11: Connection of CFQ-6912
5-14
5.Option Unit > 5.2 Installation of Power Control Unit
5.2.2
Connections to NKE-1125, NTG-3225, NKE-1130, NTG-3230, NKE-1632 and NKE-2632
Use 14-core composite cable 2695110056 for the installation of those types of antennas.
For the procedures for processing the cable end, see Fig 5-12: Equipment cable end processing.
For the wiring procedures, see 5.2.7 Inter –board connection diagram of power control unit.
5.2.3 End processing of 2695110056 cable
abt. 80 mm
Inner Shield
terminal
Outer Shield
2695110056
2695111153
taping
Width for
clamping cable.
abt. 30 mm
abt.1000 mm
Fig 5-12: Equipment cable end processing
5.2.4 End processing of each cable core
Fig 5-13: End processing of each cable core
5.2.5 Connection to display unit
Use 14-core composite cable 2695110056 and coaxial cable RG-10/UY to connect power control
unit NQE-3167 to each display unit.
Among the two cables, use coaxial cable RG-10/UY to connect the radar video signal.
For the procedures for processing the cable end and the wiring procedures, see Fig 5-12:
Equipment cable end processing. For the wiring procedures, see 5.2.7 Inter –board connection
diagram of power control unit.
5-15
5.Option Unit > 5.2 Installation of Power Control Unit
5.2.6 Outline Drawing of NQE-3167 Power Control Unit
Fig 5-14: Outline Drawing of NQE-3167 Power Control Unit
5-16
5.Option Unit > 5.2 Installation of Power Control Unit
J2
EARTH
PLATE
Fig 5-15: NQE-3167 cable entrance
Fig 5-16: NQE-3167 terminal block
Securely ground the included earth plate to the hull's earth.
5-17
5.Option Unit > 5.2 Installation of Power Control Unit
5.2.7 Inter –board connection diagram of power control unit
5.2.7.1 Inter-board connection diagram of JMR-9230-S3, JMR-7230-S3
5-18
5.Option Unit > 5.2 Installation of Power Control Unit
5.2.7.2 Inter-board connection diagram of JMR-9230-S, JMR-7230-S
5-19
5.Option Unit > 5.2 Installation of Power Control Unit
5.2.7.3 Inter-board connection diagram of JMR-9272-S, JMR-7272-S
J2
5-20
5.Option Unit > 5.2 Installation of Power Control Unit
5.2.7.4 Inter-board connection diagram of JMR-9282-S/SH, JMR-7282-S/SH
J2
5-21
5.Option Unit > 5.2 Installation of Power Control Unit
5.2.7.5 Inter-board connection diagram of JMR-9225-7X3/9X3, JMR-7225-7X3/9X3
J2
5-22
5.Option Unit > 5.2 Installation of Power Control Unit
5.2.7.6 Inter-board connection diagram of JMR-9225-6X/9X, JMR-7225-6X/9X
5-23
0.6/1kV-DPYCY-6
5-24
TB838
TB840
J832
VD+
VDTRIG+
TRIGBP+
BPBZ+
BZMTR+
MTRMTRG
(N.C.)
DC+
DC-
10
11
12
13
14
WHT
ORN
BLU
RED
NO CONNECTION
NO CONNECTION
WHT
ORN
10
11
12
13
14
15
16
J831
RIF
J839
DC_SC_IN
J837
AC_SC_IN
JUNCTION BOX
NQE-1143
400m MAX
CQD-2273 Radar Interface Circuit
RG-10/UY
COAXIAL CABLE for VIDEO (JRC SUPPLY)
H-2695110056 400m MAX
14-CORES COMPOSITE CABLE (JRC SUPPLY)
AC100-115V/AC220-240V 50/60Hz 1φ
SHIP’S MAINS
FARM+
FARMVD+
VD-
TB1
UIN
VIN
WIN
UHIN
VHIN
UHOUT
VHOUT
UOUT
VOUT
WOUT
TB3
MT+
MTMTE
VD
VDE
2TRG
2TGE
2BP+
2BP2BZ+
2BZGND
1A
2A
M+
M+
MM-
0.6/1kV-DPYCYS-1.5
AC100V,1φ,100W
10
11
12
13
14
15
16
17
18
To CCU CML-836-DC
W841:7ZCNA4164
To PSU
W853:7ZCNA4160
NO CONNECTION
+48V/TRX+
48VG/TRXHT
HTR
IS
ISR
TB2
TRG+
TRGBP+
BPBZ+
BZMTR+
MTRMTRE
POWER CONTROL UNIT
NQE-3167
STEP-DOWN
TRANSFORMER
NBL-175
MTR-
WHT
TB105
UTH
BZE
BZ
BLK
BPE
BP
TIYE
TIY
J1
1A
2A
J3
GRN
ORN
YEL.T/PNK.T
BLK.T/SKY.T
P82
LVR
PMS
P81
PTI
PTE
TXI
TXE
NJU-85
P2
LVR
PMS
P1
PTI
PTE
TXI
TXE
PERFORMANCE
MONITOR
BLK
RED
BLU
BRN
WHT
(X-BAND 25kW RADAR)
BLK
RED
BLU
BRN
WHT
Wiring of PERFORMANCE MONITOR
is completed.
JMR-9225-6XH,JMR-7225-6XHレーダー パワーコントロールユニット間 盤間接続図
AC220V, 50/60Hz, 1φ,for HEATER
SHIP’S MAINS
MTR+
VDE
VD
J2
1A
2A
J5
1A
2A
YEL
RED.T/GRN.T
PUR.T/BRN.T
WHT.T/ORN.T
BLU.T/GRY.T
J4
INTERCONNECTION DIAGRAM OF BETWEEN RADAR TYPE JMR-9225-6XH/JMR-7225-6XH
and NQE-3167 POWER CONTROL UNIT
0.6/1kV-DPYCYS-1.5
0.6/1kV-DPYCYS-1.5
CIRCUIT BREAKER
5A (SHIP YARD SUPPLY)
“D” HEATER OPTION
19-CORES COMPOSITE CABLE (JRC SUPPLY)
CFQ-6912-**
0.6/1kV-DPYCYS-1.5
SCANNER UNIT
NKE-2254-6HS
5.Option Unit > 5.2 Installation of Power Control Unit
5.2.7.7 Inter-board connection diagram of JMR-9225-6XH, JMR-7225-6XH
5.Option Unit > 5.2 Installation of Power Control Unit
5.2.7.8 Inter-board connection diagram of JMR-9210-6X/6XH, JMR-7210-6X/6XH
5-25
5.Option Unit> 5.3 Connection of VDR
5.3 Connection of VDR
5.3.1 Connection with LAN (IEC61162-450)
When the VDR have LAN port, use connection with the LAN (IEC61162-450). There is the
LAN port J4122 which is located in central control unit (NDC-1590). See the drawing below.
Fig 5-17 VDR connection connector LAN(IEC61162-450)
After the connection, please set the display unit refers to the 4.15 Setting of VDR.
5.3.2 Connection with Analog RGB
When the VDR does not have LAN port, use connection with Analog RGB.
Analog RGB signal for VDR is output from J4205 which is located in the central
control unit (NDC-1590). See the drawing below.
Fig 5-18: VDR connection connector Analog RGB
5-26
5.Option Unit> 5.4 Printer
5.3.2.1 VDR I/F kit
The VDR I/F kit is used to connection with analog RGB.
VDR I/F kit CQD-1891 includes:
DSUB15P - BNC cable (KB5BNC2K, 2 meters)
1 pcs
BNC to BNC adapter (BNC-A-JJ)
5 pcs
BNC connector (3CV-P2)
5 pcs
5 piece
Use 3C-2V coaxial cable for connection.
RED
KB-5BNC2K
NDC-1590
J4205
BNC
BNC-A-JJ
3CV-P2
3C-2V
BNC
BNC-A-JJ
3CV-P2
3C-2V
BNC
BNC-A-JJ
3CV-P2
3C-2V
BNC
BNC-A-JJ
3CV-P2
3C-2V
BNC
BNC-A-JJ
3CV-P2
GRN
BLU
RED
GRN
BLU
GRY
BLK
:red
:green
:blue
:HSYNC
:VSYNC
GRY
BLK
CQD-1891
Fig 5-19: CQD-1891 VDR I/F Kit
5-27
3C-2V
TO VDR
5.Option Unit> 5.4 Printer
5.4 Printer
Set the printer accoding to the following procedures.
When there is no keyboard operating unit, prepare the keyboard of a
USB interface.
There is a procedure that cannot be set for the keyboard not to exist.
5.4.1 Printer Composition
Externals of the printer are as follows.
●Necessary for setting
No
名称
Start Poster
AC Adaptor
CD for Printer Driver
Two sided of automatic operation print accessories
Ink
Printer Head
Print Paper
USB Keyboard
備考
When NCE-5625 Keyboard Operation Unit is
not equipped.
●Not necessary for setting
No
名称
LAN Cable
USB Cable
Warranty Card
Directions of print paper
Support documentation
備考
It doesn't use.
Use the specified LAN cable.
It doesn't use.
Please keep it with the ship importantly.
Please keep it with the ship importantly.
Please keep it with the ship importantly.
5-28
5.Option Unit> 5.4 Printer
5.4.2 Printer Assembly
Assemble a printer according to the following procedures.
①
Set up the printer according to attached “Start” poster.
② Set some papers and push the power button.
Power button
5-29
5.Option Unit> 5.4 Printer
5.4.3 Setting Printer
The setting method of the printer is described.
Set the printer according to the following procedures.
5.4.3.1 Connecting Power Cable and Printer LAN Cable
Connect power cable and printer LAN cable with the printer and main hub unit respectively. Connecting location is described to “Start” poster.
Connecting location of power cable
Connecting location of LAN cable
5.4.3.2 Confirming Printer IP Address
Confirm IP address of the printer according to the following procedures.
1. Power on Printer and ECDIS.
2. Keep pressing “Resume” button and “Wireless” button (see below diagram) at the same
time.
Confirm that 2 pieces of paper ” HP Network Configuration Page” are printed.
“Resume” but-
“Wireless” button
5-30
5.Option Unit> 5.4 Printer
3. Confirm default ”IP Address” and ”Subnet Mask” on the “HP Network Configuration
Page”.
ex)
IP Address
Subnet Mask
Default ”IP Address” and ”Subnet Mask”
5.4.3.3 Setting Printer IP Address
Set up the IP address of the printer according to the following procedures.
1. Power on this equipment.
2. After the default task starts, click the [Menu] button of the “Left Tool Bar”.
The “Menu” dialog is displayed.
5-31
5.Option Unit> 5.4 Printer
3. Click [Code Input] button.
The “Password” dialog is displayed.
4. After the password "0009" is input with the software keyboard, click the [Enter] button.
The [service] button is added to the menu. Once the [Service] button is added, it will be displayed until the task menu is finished.
5. Click the [Service] button of the “Menu” dialog.
The sub menu of [Service] is displayed.
6. Click the [Installation] button.
The “Installation” dialog is displayed.
5-32
5.Option Unit> 5.4 Printer
7. [System Configuration] is chosen by the first classification pane, and [Network] is chosen
by the second classification pane.
The “Network” dialog is displayed on the edit pane. Make a note of the present IP address.
Make a note of
the IP address.
8. According to the following explanation, input the IP address of "Own Task Station" and
click the [Set] button.
Click after
input
1st to 3rd octet
Input the default IP address of the
printer.
4th octet
Input a different value from the default IP
address of the printer.
9. Click the [Code Input] button of the “Menu” dialog. And after the password "9999" is
input with the software keyboard, click the [Enter] button.
The task is finished and it returns to the task menu screen.
5-33
5.Option Unit> 5.4 Printer
10.
Input the password "0913" into the “Code input” box of the task menu screen.
The “Internet Explore” is displayed.
11.
Input [http://IP address of printer] into the address bar.
“HP Officejet Pro 8100 N811a” page is displayed.
5-34
5.Option Unit> 5.4 Printer
Note:
When following error is displayed, delete “Temporary Internet files” as follows.
1) Start Internet explorer again. Select "Tools" - “Internet Options…"
1) Select "Tools".
2) Select “Internet Options…".
2) “Internet Options" dialog is displayed. Click [Delete...] button.
Click [Delete...] button
5-35
5.Option Unit> 5.4 Printer
3) “Delete Browsing History” dialog is displayed. Check “Temporary Internet Files” and
click [Delete] button.
1) Check "Temporary Internet files"
2) Click [Delete] button
12.
Click [Network] and select ”IPv4”of ”Wired (802.3)”.
1) Click ”Network” tab
2) Select ”IPv4”
Enter “Manual IP Address”, ”Manual Subnet Mask” and “Manual Default Gatebutton.
way” according to bellow diagram. After enter the value, click
13.
5-36
5.Option Unit> 5.4 Printer
IP Address
Subnet Mask
Default Gateway
14.
No.1 Printer
No.2 Printer
172.16.60.181
172.16.60.182
255.255.0.0
255.255.0.0
172.16.60.225
172.16.60.225
After setup, close the "Internet Explore" and start a task.
15. Return the IP address of this equipment to the original value according to the procedure of 8.
16. The IP address assigned for the printer setup is added to Network List of the Network
dialog. Check the line of relevance and click the [Delete] button.
1) Check
2) Click [Delete]button
5-37
5.Option Unit> 5.4 Printer
5.4.4 Equipment setup
The existence of a printer is set up by equipment setup of a subsystem.
Change the equipment setup of the subsystem in the “Subsystem Installation” dialog.
Note:
Refer to 4.4 "Subsystem Installation".
1. Click the [Menu] button of the “Left Tool Bar”.
The “Menu” dialog is displayed.
2. Click [Code Input] button.
The “Password” dialog is displayed.
3. After the password "0009" is input with the software keyboard, click the [Enter] button.
The [service] button is added to the menu. Once the [Service] button is added, it will be displayed until the task menu is finished.
4. Click the [Service] button of the “Menu” dialog.
The sub menu of [Service] is displayed.
5. Click the [Installation] button.
The “Installation” dialog is displayed.
6. [System Configuration] is chosen by the first classification pane, and [Subsystem Installation] is chosen by the second classification pane.
The “Subsystem Installation” dialog is displayed on the edit pane.
5-38
5.Option Unit> 5.4 Printer
7. Check [Printer] in "Device Installation" and click the [Set] button.
1) Check
2) Click [Set]button
5-39
5.Option Unit> 5.4 Printer
5.4.5 Confirming Printing Operation
Confirm the printer prints normally on the sheet according to the following procedures.
Since there is no print function in "Conning Display", it cannot confirm in
"Conning Display".
1. Click the [Print] button of “Left Tool Bar”.
Click [Print] button
2. Confirm a screen image on display is printed.
When the image cannot printed
Set the printer port refer to the following steps.
In this steps need the keyboard. When there is no keyboard operating unit, prepare the keyboard of a
USB interface.
1. Input the password [9999], and click the [Enter]. Task manager will open.
Input the password [9999]
and click the [Enter].
5-40
5.Option Unit> 5.4 Printer
2. Select the [File]-[New Task(Run…)].
Select the [New Task(Run…)].
3. Following dialog opens. Input the [explorer] and click the [OK] button.
1)Input the [Explorer].
2)Click the 「OK」 button.
4. Click the [Open Control Panel] from the open explorer.
Click the [Open Control Panel].
5-41
5.Option Unit> 5.4 Printer
5. Click the [Devices and Printers] from [Control Panel].
Click the [Devices and Printers].
6. Right-click the [HP Officejet Pro 8100(Network)] and select the [Printer properties].
1)Right click the [HP Officejet Pro
8100(Network].
2)select the [Printer properties].
7. Click the [Add Port] button from[Ports] tab.
1)Click the [Ports] tab.
2)Click the [Add Port...].
5-42
5.Option Unit> 5.4 Printer
8. Select the [Standard TCP/IP Port] and click the [New Port…] button.
1)Click the [Standard TCP/IP Port] tab.
2)Click the [New Port...] button.
9. Following dialog opens. Check the printer is connected to the network and turned on.
After checking, click the [Next] button.
Click the [Next] button.
5-43
5.Option Unit> 5.4 Printer
10. Input the No.1 Printer IP address-[172.16.60.181] and click the [Next] button.
When set the No.2 Printer, input the IP address [172.16.60.182].
1)Input the IP address.
2)Click the [Next] button.
11. Click the [Finish] button.
1)Click the [Finish] button.
Setting of the printer port is end. Restart the display unit, and confirm a screen image on display is printed.
Refer to the 5.4.5 Confirming Printing Operation.
12. Set the other display unit about the printer port By the same procedure(When the image cannot
print 1-11).
Setting of the printer port is end above.
5-44

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : admin
Create Date                     : 2015:10:15 15:07:39-07:00
Modify Date                     : 2015:10:15 15:07:46-07:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2015:10:15 15:07:46-07:00
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Creator                         : admin
Document ID                     : uuid:4dd565bd-6bc6-4a87-9513-df0389c232c0
Instance ID                     : uuid:a10fad07-3a9b-4aa9-ae15-a4622d366f4d
Producer                        : iTextSharp™ 5.5.0 ©2000-2013 iText Group NV (AGPL-version); modified using iTextSharp™ 5.5.0 ©2000-2013 iText Group NV (AGPL-version)
Page Count                      : 44
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CKENKE2632

Navigation menu