Japan Radio NKE2632 Solid State S-Band Marine Radar User Manual Instruction Manual Operation Part 2

Japan Radio Co Ltd. Solid State S-Band Marine Radar Instruction Manual Operation Part 2

Instruction Manual Operation Part 2

Download: Japan Radio NKE2632 Solid State S-Band Marine Radar User Manual Instruction Manual Operation Part 2
Mirror Download [FCC.gov]Japan Radio NKE2632 Solid State S-Band Marine Radar User Manual Instruction Manual Operation Part 2
Document ID2791057
Application IDo6LERARSP56i/cSy+lEJSg==
Document DescriptionInstruction Manual Operation Part 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize303.41kB (3792570 bits)
Date Submitted2015-10-22 00:00:00
Date Available2015-10-22 00:00:00
Creation Date2015-10-15 15:18:15
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2015-10-15 15:18:22
Document TitleInstruction Manual Operation Part 2
Document CreatorWord 用 Acrobat PDFMaker 11
Document Author: PCUser

Section 2 Name and Function of
Each Unit
2.1
Name and Main Function of the
Operation Unit
2.1.1
Trackball operation unit
[1]
[5]
[2]
[6]
[3]
[7]
[4]
[8]
[10]
[9]
When turning off the power supply, do not hold down the power button of
the operation unit.
Otherwise, a trouble may occur due to termination failure.
No.
Name
Power supply button
[MULTI] dial
USB terminal
[SILENCE] key
[ALERT ACK] key
[ZOOM IN] key
Function outline
Use this button to turn on and off this equipment.
• Turn this dial to operate the function that is assigned to the [MULTI] dial such as
the Display Brightness function.
• If the [MULTI] dial is held down, the Display Brightness function is assigned to
the [MULTI] dial forcibly.
Connects a USB flash memory.
Stops the alert buzzer.
Acknowledging the alert.
• "Observation range" Setting will increment one step smaller in the case of
RADAR.
• "Scale" Setting will increment one step larger in the case of ECDIS.
• When this key is held pressed, setting will step continuously until released.
2-1
Section 2
Name and Function of Each Unit
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
No.
Name
[ZOOM OUT] key
Track ball
Left button
10
Right button
Function outline
• "Observation range" Setting will increment one step larger in the case of
RADAR.
• "Scale" Setting will increment one step smaller in the case of ECDIS.
• When this key is held pressed, setting will step continuously until released.
Moves the cursor on the screen. Use the track ball to specify a position or to
perform various settings.
• Use this button to select a function or determine the operation that is set.
• The clicking of the left button once is referred to as "click" in this manual.
• The clicking of the left button twice consecutively is referred to as "double click"
in this manual.
• Use this button to select a function or perform setting operation.
• The clicking of the right button is referred to as "right click" in this manual.
2.1.2 Keyboard operation unit (Option)
[1]
[6]
[3] [7] [8] [4]
[9] [5]
[14]
[10]
[11]
[12]
[2]
[15]
[13]
[16]
No.
Name
[EBL] dial
[VRM] dial
[RAIN] dial
[SEA] dial
[GAIN] dial
[TX STBY] key
[AZ] key
Section 2
Function outline
When this dial is turned, control moves in the EBL (PI) direction with control right.
This dial also moves the cursor horizontally (in cursor move mode).
When this dial is turned, control moves in the VRM (PI) direction with control right.
This dial also moves the cursor vertically (in cursor move mode).
• When this dial is turned, the level of rain/snow clutters on the radar image is
adjusted.
• When this dial is pressed, the function mode is switched to manual/automatic.
• When this dial is turned, the level of sea clutters on the radar image is adjusted.
• When this dial is pressed, the function mode is switched to manual/automatic.
• When this dial is turned, the gain of the radar image is adjusted.
• When this dial is pressed, the transmission pulse width is switched.
[For RADAR]
• When this dial is pressed, the radar transmission status is switched to Standby or
Transmit.
[For ECDIS]
When this dial is pressed, the radar image on the chart is switched to "On" or "Off".
• This key switches AZ to On/Off.
• When this key is held down, the “[AZ] Key Assignment” dialog box appears.
Name and Function of Each Unit
2-2
No.
Name
[HOME] key
[DAY NIGHT] key
10
[DISP OFF] key
11
[PI] key
12
[MOB] key
13
[PANEL] key
14
[USER1] key
15
[USER2] key
16
Keyboard
Function outline
• Returns own ship to the home position within the display screen.
- TM: Moves the own ship to the TM RESET position.
- RM: Moves the own ship to the on-center position (when it is at off-center only).
Switches the display color on the screen over 5 levels according to the brightness
on the bridge.
The assigned function is executed while the key is pressed.
The function that can be assigned is Data Off or HL Off for RADAR and Data Off for
ECDIS.
• Switches the PI operation/display to On/Off.
For PI operation, refer to "4.6 Using Parallel Index Lines (PI)".
• When this key is held down, the cursor mode is changed to the floating PI mode.
• Displays the MOB symbol and the setting dialog box in the own ship’s position
latitude/longitude.
• When this key is held down, the MOB symbol and the setting dialog box are
cleared.
Whenever this key is pressed, the brightness of the panel on the operation unit is
switched.
• Executes the function that is assigned to the key.
• When this key is held down, the setting dialog box of the function that is assigned
to the [USER1] key appears.
• Executes the function that is assigned to the key.
• When this key is held down, the setting dialog box of the function that is assigned
to the [USER2] key appears.
The keyboard is used for input of numeric values and characters at operation of this
equipment.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-3
Section 2
Name and Function of Each Unit
2.1.3 Display unit
[Brightness Adjustment] [Power] button
buttons
[Power] button
When the Power button is pressed while the power of the display unit is turned off, the power is
turned on.
To turn off the power of the display unit, press the Power button for 5 seconds or longer.
[Brightness Adjustment] buttons
These buttons are used to adjust the brightness of the screen.
The screen increases brightness by pressing the
button.
The screen decreases brightness by pressing the
button.
Memo
Adjust the brightness of the screen to the extent it is not dazzling, taking into account the
brightness of the surroundings and to the brightness which you can be easily observed the
RADAR, the ECDIS screens.
Section 2
Name and Function of Each Unit
2-4
2.2
Names and Main Functions of the
Task Screen Common Sections
This section describes the names of task screen common sections and outlines the main functions.
Refer to "2.2.4 Key assignment
indication area".
Refer to 2.2.3 "Alert notification area
Alert Notification Area".
Refer to "2.2.1 Right
Toolbar
Refer to "2.2.6 Own
Ship Information".
Refer to "2.3 Common
Information Window".
Refer to "2.2.2 Left Toolbar".
Refer to "2.2.5 Navigation Tools".
Display Example on the RADAR Screen
Refer to "2.2.4 Key assignment display area".
Refer to "2.2.3 Alert Notification Area".
Refer to "2.2.1 Right
Toolbar".
Refer to "2.2.6 Own
Ship Information".
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
Refer to "2.2.2 Left Toolbar".
APP B
Display Example on the ECDIS Screen
2-5
Section 2
Name and Function of Each Unit
2.2.1 Right Toolbar
The functions of the buttons of the right toolbar are as follows.
Day/Night button
The display color on the screen can be
switched to 5 levels according to the
brightness on the bridge.
For the details, refer to "3.8 Switching the
Day/Night Mode ".
Message notification button
When this button is clicked on, the message dialog box relating to
the latest notification message is displayed among the information
received on AIS MSG Tray.
For the message dialog box of each of the information received,
refer to "2.3.2 Information reference windows".
The total number of unread messages is displayed on the badge.
Display and Panel Brightness button
MOB (Man Over Board) button
For the details, refer to "3.9 Adjusting the
Brightness of the Screen and Operation
Unit".
For the details, refer to "3.10 MOB (Man
Over Board)".
The brightness of the screen and operation
unit can be switched within the range from 0
to100.
When a person falls overboard, use this
button to mark the own ship’s position
when the button is clicked on, so as not to
lose the sight of the position.
Task switching button
This button switches the task screen.
• When the button is clicked on, task switching thumb
nails are displayed to enable selection of a task screen.
• When one of the thumb nails on the dialog box is clicked
on, the screen is switched to the applicable task screen.
Memo
The first letter of the task screen that is currently displayed is displayed on the task switching
button.
RADAR: R
ECDIS: E
Conning Display: C
AMS: A
Example: ECDIS is displayed.
Section 2
Name and Function of Each Unit
2-6
1
2.2.2 Left Toolbar
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
The functions of the buttons of the Left Toolbar are as follows.
Some buttons on the Left Toolbar are normally displayed and others are not.
Click on the Disclosure button to switch the display.
Normal non-display
Normal display
Disclosure
button
When the disclosure
button is clicked on,
the normal
non-display buttons
are displayed.
Refer to the next page for the name and function of each button.
APP A
APP B
2-7
Section 2
Name and Function of Each Unit
2.2.2.1 Buttons that are normally displayed
[Auto] (Cursor mode selection)
button
PEN (Write tool) button
When this button is clicked on, the cursor
mode is switched to the AUTO mode.
For the details of the cursor mode, refer to
"3.12 Cursor AUTO Mode".
Clicking on this button during user map
creation, manual chart update or route
planning brings up the corresponding
operation mode.
The mode name will be indicated on the
button.
[Undo] button
Clicking on this button cancels the
previous operation performed.
- In user map creation mode
- In manual update creation mode
[Data OFF] button
When this button is clicked on, only the
main information is displayed from the
screen display and other information is
hidden.
The following information items are
displayed:
Example: [U.Map] (User Map) mode
[U. Map] (User Map) mode
Clicking on the button when it indicates
[U. Map] displays the drawing toolbar for
user maps.
*When this mode is used, the azimuth
mode will be fixed to N UP (North UP).
RADAR
- Echo/trail
- Cursor
[Update] (Manual Update) mode
Clicking on the button when it indicates
[Update] displays the "Select Chart"
dialog box if a chart to be manually
updated has not been selected. If a chart
to be manually updated is selected, the
drawing toolbar for manual update will be
displayed.
*When this mode is used, the azimuth
mode will be fixed to N UP (North UP).
[Route] (Route Planning) mode
Clicking on the button when it indicates
[Route] brings up a new route planning
mode if no route planning tab is open. If
one or more route planning tabs are
open, the system switches from the end
of the routes currently being created to
the WPT addition mode.
ECDIS
- Own ship’s symbol
- Route
- Temporary Route
- Chart
- Manual update object
- EBL
- VRM
- Cursor
*The chart is displayed when the display
category is [Base].
[Menu] button
When this button is clicked on, the top menu for the
RADAR and ECDIS screens is displayed.
For the details of the menu, refer to "3.4 Basic Menu
Operations".
Memo
This equipment is operating normally when the
[Menu] button is moving in animation mode.
When this equipment is set to a freeze state, the
Menu button stops and does not move. In this
case, turn off the power once and turn it on again.
Section 2
Name and Function of Each Unit
2-8
1
2.2.2.2 Buttons that are normally hidden
[Chart On/Off] button
Clicking on this button switches to show
or hide the chart.
[Map On/Off] button
Clicking on this button switches to show or
hide the user map.
Even if the mode is set to Hide, the
Mariner’s Mark/Line symbol and various
Warning symbols are displayed.
[HL Off] button
When this button is clicked on, the
Heading Line becomes hidden.
For the details of the Heading Line, refer
to "16.2.1 Setting up the Display of Own
Ship Symbol".
[Screen Capture] button
When this button is clicked on, the screen
that is currently displayed is captured.
[Printer] button
For the details, refer to "3.13 Saving the
Screen that is Currently Displayed".
To print the screen, click on this button.
(This button is displayed only when a
printer is installed.)
[Eraser tool] button
When this button is clicked on, the User
Map Erase mode is set, enabling
continuous erasing.
2.2.3 Alert notification area
When an alert occurs, the alert status, the contents of the alert and the occurrence count are displayed
in the alert notification area.
For the details, refer to "3.7 Confirming and Acknowledging an Alert ".
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-9
Section 2
Name and Function of Each Unit
2.2.4 Key assignment indication area
When the [MULTI] dial is turned, the assigned functions are operated.
For the function assignment, refer to "3.14 [Multi] dial".
2.2.5 Navigation tools
The tools that are used for measurement are displayed.
[PI] button
Use this button to operate the parallel index line cursor.
For the details, refer to "4.6 Using Parallel Index Lines (PI)".
EBL/VRM operation button area
Use this button to operate EBL/VRM.
[Cursor] (Cursor information
For the details, refer to "4.5.1 Measuring a range and a
bearing with EBL and VRM"
display) button
When this button is clicked on, the
"Cursor Readout" dialog box appears.
For the details, refer to "4.3 Using the
Cross-hair Cursor".
Section 2
Name and Function of Each Unit
2-10
1
2.2.6 Own Ship Information
Do not use the offset function during navigation.
If the equipment is used with the offset value entered as the own ship position
(deviated from the actual position), accidents may result.
When the offset values are entered, the [Offset] badge is displayed at the position
display on the Own Ship Information. Check the indication, and cancel the offset
function if necessary. Also, the message "Position Shift" is displayed in the message
display area.
This window displays the own ship’s information.
•
When using 1-axis log, heading speed component can be detected, but transverse
speed component cannot be detected. Then leeway effect (component drifted by
wind) cannot be detected.
•
When using 2-axes log, its accuracy in shallow waters may be deteriorated, and its
speed in deep sea areas may be unable to be detected.
•
When using a GPS, COG accuracy is less than ±3° at speed: from 1kn to 17kn, and
is less than ±1° at speed: more than 17kn.
UTC/Local date and time
This button displays the current date and time.
• When the button is clicked on, the time can be switched
to the UTC time display or Local time display.
• Set the time format by selecting [Maintenance] -
[Date/Time/Time Zone]-[Display Style] on the
menu.
For the details, refer to "21.1.2 Setting Date/Time/Time
Zone".
See the next page.
Sensor information
Various sensor information items are displayed.
[Sensor types]
Sensor name
HDG
STW
COG/SOG
Contents
Displays the value indicated by the ship’s heading sensor.
Displays the value indicated by the speed through water sensor.
Displays the value indicated by the speed over the ground sensor.
APP A
[Sensor value background colors]
Each background color represents the following meaning.
Normal color: Normal sensor value
Yellow: The reliability of the sensor value is deteriorating.
Red: The sensor value is abnormal.
2-11
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP B
Section 2
Name and Function of Each Unit
[Switching the sensor source]
Select the sensor source in the [Source] combo box. The following sensor sources can be selected.
When [Menu] is selected, the "Sensor Selection/Status" dialog is displayed.
Sensor name
Sensor source
HDG
MAN (Manual) *4, Gyro, Gyro 1*1*5, Gyro 2*1*5, MAG (MAG Compass)*5, G/C (GPS
Compass)
STW
MAN (Manual) *4, Log, Log 1*2, Log 2*2
COG
Log, Log 1*2, Log 2*2, GPSx*3
SOG
*1: Only when there are two Gyros.
*2: Only when there are two Logs.
*3: When two or more GPS units are present, “x” indicates the unit number.
*4: This can only be selected from the “Sensor Selection/Status” dialog.
*5: When the Gyro Compass system that is used has the automatic switching function, the display of the sensor
source changes automatically according to the switching condition.
See the previous page.
Position
Displays Position information.
[1]
[4]
[2]
[5]
[3]
[1] The data name of the Position is displayed.
[2] The sensor source of the Position is displayed.
Select a sensor source in the [Source] combo box. Any of the following sensor sources can be selected.
When [Menu] is selected, the “Sensor Selection/Status” dialog is displayed.
Data name
Sensor source
POSN(Main) for ECDIS and Position
GPSx*, DR
for RADAR
*: When two or more GPS units are present, “x” indicates the unit number.
Section 2
Name and Function of Each Unit
2-12
1
[3] A geodetic positioning system is displayed. It is fixed to "WGS-84".
[4] Positioning precision display
When the positioning precision is differential positioning, "DGPS" is displayed. No information is displayed
in the case of GPS single positioning.
[5] Position (CCRP)
The CCRP position indicated by the primary positioning sensor is displayed.
Own ship’s position offset display
When offset is set for the own ship’s position, the icon that indicates the offset status is
displayed for the Position.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-13
Section 2
Name and Function of Each Unit
2.3
Common Information Window
The common information window is commonly used by RADAR and ECDIS.
The information that is displayed on the Common Information Window can be classified into
information monitoring and information referencing.
An information monitoring window is used together with radar PPI and a chart, and the information
includes TT/AIS value information, wave information, conning blocks, etc.
•
Information monitoring windows are displayed at the bottom right corner of the screen in RADAR.
In ECDIS, although the windows are displayed at the bottom right corner of the screen at the initial
display, the display positions can be moved as floating windows.
The information reference is the window that is temporarily referenced according to the user request
and the information includes AIS messages, alert information, and own ship AIS information.
•
The information reference window can be switched to either the standard window display or the
extended window display. For the details of the switching between the standard window and the
extended window, refer to "2.3.2.1 Switching between a standard window and an extended
window".
Information monitor window
Information reference window
Display example under RADAR screen
Section 2
Name and Function of Each Unit
2-14
1
Information reference window
Information
monitor
window
Display example under ECIDS screen
Memo
This section provides the overview of each common information window.
For the operations and settings of the common information windows, refer to "3.6 Operation of the
Information Monitor Window".
2.3.1 Information monitor windows
Information monitoring related windows is as follows.
Item
Contents
Related section
Target INFO
TT/AIS movement information
2.3.1.1 Target INFO
TT List (for RADAR)
TT target risk sequence list
2.3.1.2 TT List
AIS List
AIS target risk sequence list
2.3.1.3 AIS List
AIS Detail INFO
Detail information relating one AIS
target
2.3.1.4 AIS Detail INFO
2nd PPI
Radar 2nd PPI
2.3.1.5 2nd PPI
Wave Analysis (option)
Wave analysis information
2.3.1.6 Wave Analysis (option)
Current/Wind
Wind speed and current information
2.3.1.7 Current/Wind Block
Conning
Conning
2.3.1.8 Conning
TT1 List, TT2 List1 (for ECDIS)
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-15
Section 2
Name and Function of Each Unit
2.3.1.1 Target INFO
Target INFO is the display monitor window that displays movement information of TT/AIS.
In Target INFO, TT information, AIS information, and AIS extended information are displayed.
Memo
When the screen is a 26inch screen and the mode is the RADAR mode, Target Info is also
displayed in the Extra Target INFO Area.
Extra Target
INFO Area
TT information display
Section 2
Name and Function of Each Unit
2-16
1
The following information items are displayed.
Explanation
Displayed
information
TT ID
Displays the identification number (1 to 100) of a TT target.
BRG
Displays the bearing of a TT target.
Range
Displays the distance to a TT target.
COG or CTW
Displays the course of a TT target. Displayed as "COG" in the course over the
ground mode and "CTW" in the course through the water mode.
SOG or STW
Displays the ship speed of a TT target. Displayed as "SOG" in the speed over
the ground mode and "STW" in the speed through the water mode.
CPA
Displays the distance of the closest point of approach to the TT target.
TCPA
Displays the arrival time of the closest point of approach to the TT target.
BCR
Displays the bow crossing range of a TT target.
BCT
Displays the bow crossing time of a TT target.
AIS information
Standard display
Extended display
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-17
Section 2
Name and Function of Each Unit
•
AIS information of the target is displayed.
•
When the
(AIS standard/extension switching) button is clicked on, the display is switched
between the standard display and the extended display.
•
The following information items are displayed.
Displayed information
AIS ID
Explanation
Displays the identification number (1 to 1000) of an AIS target.
*The maximum display number is 1000 as the option.
Name
Displays the ship name of an AIS target.
Call Sign
Displays a call sign.
MMSI
Displays a nine-digit identification number for a ship/ground station
equipped with a DSC communication device.
COG or Course
Displays the course of an AIS target. Displayed as "COG" in the course
over the ground mode and "Course" in the course through the water
mode.
SOG or STW
Displays the ship speed of an AIS target. Displayed as "SOG" in the
speed over the ground mode and "STW" in the speed through the water
mode.
CPA
Displays the closest approach distance to an AIS target.
TCPA
Displays the time to reach the closest approach point to an AIS target.
BRG*
Displays the bearing of an AIS target.
Range*
Displays the distance to an AIS target.
Heading*
Displays the heading of an AIS target.
ROT*
Displays the turning speed of an AIS target.
POSN and Position
Displays the position of an AIS target and position-fix accuracy.
Accuracy*
When the position-fix accuracy is low, [>10m] is displayed.
When the position-fix accuracy is high, [<10m] is displayed.
Destination*
Displays the destination of an AIS target.
Navigation Status*
Displays the navigation conditions of an AIS target.
For detailed explanation, refer to "Navigation Status" in the table provided
in "2.3.1.4 AIS Detail INFO".
*: Extended display only
Section 2
Name and Function of Each Unit
2-18
1
AIS SART information
AIS SART information is displayed by using an extended display.
Unlike the AIS information extended display, the following items are not displayed.
•
Call Sign
•
Destination
•
(AIS standard/extension switching) button
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-19
Section 2
Name and Function of Each Unit
2.3.1.2 TT List
A TT List lists the degrees of risks of TT targets.
For the details, refer to "6.14.2 Displaying the TT/AIS Target List".
2.3.1.3 AIS List
The AIS List lists the degrees of risks of AIS targets.
For the details, refer to "6.14.3 AIS List".
Section 2
Name and Function of Each Unit
2-20
1
2.3.1.4 AIS Detail INFO
This window displays detail information on one AIS target.
AIS information of the target is displayed.
When either one of
is clicked on, AIS information before or after the information currently
displayed is displayed.
The following information items are displayed.
Displayed information
AIS ID
Explanation
Displays the identification number (1 to 1000) of an AIS target.
*The maximum display number is 1000 as the option.
Name
Displays the ship name of an AIS target.
Call Sign
Displays a call sign.
MMSI
Displays a nine-digit identification number for a ship/ground station
equipped with a DSC communication device.
IMO No.
Displays the 9-digit IMO number.
Length
Displays the length of an AIS target.
Beam
Displays the beam of an AIS target.
Destination
Displays the destination of an AIS target.
ETA or UTC
Displays the expected arrival time of an AIS target.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-21
Section 2
Name and Function of Each Unit
Displayed information
Navigation Status
Explanation
Displays the navigation conditions of an AIS target.
0: Under Way Using Engine
1: At Anchor
2: Not Under Command
3: Restricted Maneuverability
4: Constrained by Her Draught
5: Moored
6: Aground
7: Engaged in Fishing
8: Under Way Sailing
9: Reserved for HSC
10: Reserved for WIG
11: Reserved
15: Not Defined
Draft
Displays the draft of an AIS target.
Type of Ship
Displays the ship type of an AIS target.
30: Fishing Vessel
31: Towing Vessel
32: Towing Vessel L>200M B>25M (Towing and length of the tow
exceeds 200m or breadth exceeds 25m)
33: Dredge or Underwater OPE (Engaged in dredging or underwater
operation)
34: Vessel-Diving OPE (Engaged in diving operation)
35: Vessel-Military OPE (Engaged in military operation)
36: Sailing Vessel
37: Pleasure Craft
50: Pilot Vessel
51: Search and Rescue Vessels
52: Tugs
53: Port Tenders
54: With Anti-Pollution Equip(Vessels with anti-pollution facilities or
equipment)
55: Law Enforcement Vessels
58: Medical Transports
59: Resolution No18:MOB-83(Ships according to Resolution
No18(Mob-83))
2X: WIG(Wing-in-Ground Effect Craft)
4X: High Speed Craft
6X: Passenger Ships
7X: Cargo Ships
8X: Tanker
9X: Other Type of Ship
Section 2
Name and Function of Each Unit
2-22
Displayed information
Cargo Category
Explanation
When the setting of the type of a ship is
2X, 4X, 6X, 7X, 8X or 9X, the digit shown at the end of the code
represents the cargo/condition.
X1 Category X(DG/HP/MP)
X2 Category Y(DG/HP/MP)
X3 Category Z(DG/HP/MP)
X4 Category OS(DG/HP/MP)
X9 No Additional Information
X0 All Ships of This Type
Bearing
Displays the bearing of an AIS target.
Range
Displays the distance to an AIS target.
COG or CSE
Displays the course of an AIS target. Displayed as "COG" in the course
over the ground mode and "CSE" in the course through the water mode.
SOG or STW
Displays the ship speed of an AIS target. Displayed as "SOG" in the
speed over the ground mode and "STW" in the speed through the water
mode.
CPA
Displays the closest approach distance to an AIS target.
TCPA
Displays the time to reach the closest approach point to an AIS target.
BCR
Displays the bow crossing range of an AIS target.
BCT
Displays the bow crossing time of an AIS target.
Heading
Displays the heading of an AIS target.
ROT
Displays the turning speed of an AIS target.
Position
Displays the position of an AIS target and position-fix accuracy.
When the position-fix accuracy is low, [>10m] is displayed.
When the position-fix accuracy is high, [<10m] is displayed.
Position Sensor
Displays the type of the position sensor used by an AIS target.
0: Not Defined
1: GPS
2: GLONASS
3: Combined GPS/GLONASS
4: Loran-C
5: Chayka
6: Integrated Navigation System
7: Surveyed
8: Galileo
15: Internal GNSS
Status
Status of an AIS target
• Sleeping
• Activated
• Lost
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
• Danger
• Selected
APP B
2-23
Section 2
Name and Function of Each Unit
2.3.1.5 2nd PPI
The setting items are the same as those of the main PPI setting except for the setting items that can be
specifically set under 2nd PPI.
For the details, refer to "2.4.1 Presentation and mode information".
[4]
[5]
RADAR Source ANT2
[1]
▼
[6]
[2]
[7]
[3]
Note
In “screen fixed display” (C mode), EBL/VRM is not displayed in the 2nd PPI.
Memo
When the numbers of the direction graduations become overlapped and cannot be distinguished,
the numbers will be thinned out and displayed.
[1] Range scale combo box
Select a range scale from the combo box and set up the range scale.
[2] [In] (Zoom In) button
When this button is clicked on, the display is zoomed in by one level from the range scale. When the
button is held down, the display is zoomed in continuously.
Section 2
Name and Function of Each Unit
2-24
1
[3] [Out] (Zoom Out) button
When this button is clicked on, the display is zoomed out by one level from the range scale. When the
button is held down, the display is zoomed out continuously.
[4] Motion mode combo box
Select a motion mode from the combo box and set up the motion mode. The mode operates by linking
with the setting of the main PPI.
[5] Bearing mode combo box
Select a bearing mode from the combo box and set up the bearing mode The mode operates by linking
with the setting of the main PPI.
[6] Range rings display button
When this button is clicked on, the range rings display surrounding the own ship is set to On/Off.
[7] [Off Center] button
When this button is clicked on, the off-center of the own ship’s position (CCRP) is set to On/Off.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-25
Section 2
Name and Function of Each Unit
2.3.1.6 Wave Analysis (option)
Wave Analysis analyzes sea clutters that are detected by a radar and measures the wave height, wave
direction, cycle and wave length around own ship.
[1]
[2]
[6]
[3]
[5]
[4]
[7]
[9]
[8]
19inch screen
Section 2
Name and Function of Each Unit
2-26
1
[1]
[6]
[2]
[3]
[5]
[8]
[9]
[4]
[7]
26inch screen
[1] [Mode] (Calculation execution mode)
The calculation execution mode is displayed. Three modes are available, [Real Time], [Interval] and
[Display].
•
[Real Time] mode: Outputs analysis results at a 1-minute interval.
•
[Interval] mode: Outputs analysis results at the set interval (5 to 120 minutes).
•
[Display] mode: Displays the latest analysis result. Analysis is not performed.
[2] [Rec RADAR] (Recording radar data log)
Displays whether the recording of radar data log is set to ON or OFF.
Radar echo data that is received from a sensor at the cycle of 2.4 seconds is saved in the png format
(about 100KB/sheet) and inf file (about 1KB/sheet) as the log. The storing period can be set within
the range from 1 to 300 days.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-27
Section 2
Name and Function of Each Unit
[3] [Last Update] (Analysis time)
Displays the time when the last analysis was performed.
Memo
The time is displayed in the format that was set in [Display Style] after selecting [Maintenance] [Date/Time/Time Zone] on the menu.
[4] [DISP Mode] button
Select a display mode of the wave direction.
When displaying in North Up, set [N UP] by clicking on the button.
When displaying in Head Up, set [H UP] by clicking on the button.
[5] Analysis result
Displays the analysis result.
[Height] (wave height), [Length] (wave length), [Period] (wave cycle), and [Direction] (wave direction)
are displayed for each Primary (primary waves) and Secondary (secondary waves) that come from
multiple directions.
[6] Status
On the left column (19inch screen)/upper level (26inch screen), [Calc] (calculating), [Stopped]
(stopping), or Interval (under interval) is displayed as the analysis status.
On the right column (19-inch screen)/lower level (26-inch screen), [Success] (successful) or Halt [01]
(not SP mode)) is displayed as the analysis result.
[7] [Save Log] button
When this button is clicked on, the save dialog of the analysis result log is displayed.
To save the log, click on the [Save] button.
The radar echo data (about 60 sheets) that was used for output of the analysis result that is currently
displayed is saved.
The contents are the same as for the png file and the inf file that are saved by [RecRADAR].
To delete the log that has been saved, select the log from the list and click on the [Delete] button.
When the button is clicked on, a deletion confirmation dialog is displayed. To execute the deletion,
click on the [OK] button.
Section 2
Name and Function of Each Unit
2-28
1
Memo
The log saving date and time are displayed in the format that is set in [Display Style] after
selecting [Maintenance] - [Date/Time/Time Zone] on the menu.
[8] [Show Spectrum] button
When this button is clicked on, the "Wave Spectrum" window is displayed.
The “Wave Spectrum” window displays the result of wave analysis using the RADAR in a spectrum.
The angle on the circle indicates the angle of incoming wave and the concentric circle indicates the
wave cycle.
(a)
(b)
(c)
(a) [N UP] and [H UP]
The wave direction is displayed with [N UP] (true bearing display) or [H UP] (relative bearing
display).
The display is linked to [Display Mode] of the "Wave Analysis" window.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-29
Section 2
Name and Function of Each Unit
(b) [Last Update] (analysis time)
Displays the time when the last analysis was performed.
Memo
The time is displayed in the format that is set in [Display Style] after selecting [Maintenance] [Date/Time/Time Zone] on the menu.
(c) Analysis result
Displays [Height] (wave height), [Length] (wave length), [Period] (wave direction), and [Direction]
(wave direction) of Primary (primary wave).
[9] [Adjustment] button
Clicking this button causes the "Regression Coefficient Adjustment" (peak value regression
coefficient adjustment) dialog to be displayed.
(a)
(b)
(c)
(d)
(f)
(e)
(g)
(h)
(i)
(a) [Current Wave Height]
The wave height determined by radar wave analysis is displayed.
(b) [Observed Wave Height] (Observed peak value)
Input the observed peak value.
(c) [Set] button
Clicking this button causes the current wave height value and observed peak value to be added
to the peak value list.
Section 2
Name and Function of Each Unit
2-30
The added wave height value and observed peak value are automatically stored in the file.
A maximum of 100 data items can be displayed.
When the number of data items reaches 100, the pop-up menu appears to indicate that there
are 100 data items when you have clicked the [Set] button. Clicking the [OK] button allows the
pop-up menu to be closed.
(d) Peak value list
The current wave height value, observed peak value and time of observation is displayed.
(e) [Delete Data] button
The data selected on the peak value list will be deleted.
Clicking this button causes the delete confirmation dialog to appear. To execute deflection, click
the [OK] button.
(f) [Save File] button
This button is used to assign a file name to the data saved by clicking the [Set] button, and to
save the same data, or to specify another destination location to the data there.
Clicking this button causes the "Save File" dialog box to appear.
Folder tree
After selecting the save destination in the [Drive] combo box and the folder of the save
destination in the folder tree, enter the file name in the [File Name] input box. After checking that
wvh is displayed in the [File of type] (file type) combo box, click on the [Save] button.
When a display unit is selected in the [Drive] combo box, the save target folder cannot be
changed.
If the file having the same name is present in the destination location, a confirmation dialog will
appear to ask you if overwriting is desired or not. If overwriting is required, click on the [Yes]
button.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-31
Section 2
Name and Function of Each Unit
(g) [Load File] button
The file saved by the [Save File] button is read out.
Clicking this button causes the "Load File" dialog to appear.
Folder tree
Select the read destination on the [Drive] combo box, and select the folder on the read
destination using the folder tree. After that, select from the file list the file to be read out. Then
click on the [Load] button.
When a display unit is selected in the [Drive] combo box, the read target folder cannot be
changed.
(h) [Delete File] button
The save file is deleted.
Clicking this button causes the "Delete File" dialog to appear.
Folder tree
Select the location of the file to be deleted using the [Drive] combo box and the folder tree. After
that, select the file to be deleted from the file list. Then click on the [Delete] button.
Section 2
Name and Function of Each Unit
2-32
1
(i) [Show Scatter Plot] (scattergram indication) button
Clicking this button causes the "Scatter Plot" (scattergram) window to be displayed.
[a]
[b]
[c]
[a] Scattergram
This horizontal axis represents the S/N and the vertical axis shows the observed peak value
scattergram.
[b] [Regression Coefficient 2A] (regression line α value)
The α value (Gradient 'a' of regression line y=ax+b) of the regression line will be shown.
[c] [Regression Coefficient 2B] (regression line β value)
The β value (Contact 'b' of regression line y=ax+b) of the regression line will be shown.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-33
Section 2
Name and Function of Each Unit
2.3.1.7 Current/Wind Block
The Wind/Current Block shows the wind speed and current information.
[6]
[8]
[1]
[7]
[3]
[2]
[5]
[4]
26inch screen
19inch screen
[1] Wind/Current meter
Displays the wind speed and current.
The display varies depending on the setting of the [N-UP]/[H-UP] (N-UP/H-UP switching) button.
[a]
[c]
[d]
[b]
[b]
[c]
[d]
[a]
N-UP display
H-UP display
[a] Wind bearing/speed
Indicates the wind bearing/wind speed.
Arrow feathers are shown when N-UP is selected.
The arrowhead indicates a leeward direction. The number of feathers indicates the wind speed.
Memo
The number of feathers is based on the Beaufort scale.
A triangle arrow is shown when N-UP is selected.
The arrowhead indicates a leeward direction.
Section 2
Name and Function of Each Unit
2-34
1
[b] Flow direction/speed
Indicates the flow direction.
The arrow indicates the direction of the current.
[c] Ship’s heading
Indicates the ship's heading.
When N-UP is selected, the north of the direction ring of the meter is fixed on top, and the own
ship symbol rotates to indicate the heading.
When H-UP is selected, the ship's heading is fixed on top to show the direction.
[d] Ground direction
Indicates the ground direction.
[2] [N-UP]/[H-UP] button (Displayed only for 26inch display)
Used to change the display method for the ship's heading.
When the [N-UP] button is clicked, the north of the direction ring of the meter is fixed on top, and the
own ship symbol rotates to indicate the heading.
When the [H-UP] button is clicked, the ship's heading is fixed on top to show the direction.
[3] Legends
Legends of the Wind/Current meter
[4] Wind bearing/speed information
Shows the wind bearing/speed information.
Display varies depending on the ship's heading display method.
Ship's heading display is N-UP
Ship's heading display is H-UP
For N-UP, [Bearing] (wind bearing), [Speed] (wind speed), and [BFT] (Beaufort scale) are shown as
numerical values.
When H-UP is selected, [Bearing] (wind direction) and [Speed] (wind velocity) are displayed in
numerical values. For a 26-inch screen, either of the following symbol is also displayed.
: Indicates the windward is on S (starboard) side.
: Indicates the windward is on P (port) side.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
Memo
APP B
No symbol is displayed with the wind bearing 0°or 180°.
2-35
Section 2
Name and Function of Each Unit
[Speed] (wind speed) is shown as a numerical value.
[5] Tidal current information
Shows the tidal current information.
Display varies depending on the ship’s heading display method.
Ship’s heading display is N-UP
Ship’s heading display is H-UP
[Set] (tidal current direction) and [SPD] (flow speed) are displayed in numerical values.
For 26-inch screen, either of the following symbols is also displayed.
: The downstream is on the S (starboard) side.
: The downstream is on the P (port) side.
Memo
When the tidal current bearing is 0° or 180°, no symbol is displayed.
[6] Wind bearing/speed information
Shows the wind bearing/speed information.
Display varies depending on the wind bearing true/relative display method.
True wind bearing
Relative wind bearing
For True wind bearing, [Bearing] (wind bearing), [Speed] (wind speed), and [BFT] (Beaufort scale)
are shown as numerical values.
For display of a relative bearing, [Bearing] (wind direction) and [Speed] (wind velocity) are displayed
in numerical values.
[7] Tidal current information
Shows the tidal current information.
Tidal current information is displayed as follows according to the tidal current true/relative direction.
Section 2
Name and Function of Each Unit
2-36
1
True current direction
Relative current direction
[Set] (current direction) and [Speed] (flow speed) are shown as numerical values.
[8] [True]/[Relative] (True/Relative wind switching) button (Displayed only for 19inch display)
Switches between True and Relative display for wind bearing and tidal current.
Click the [True] (true wind bearing) button to show wind bearing and tidal current in the true direction.
Click the [Relative] (relative wind bearing) button to show wind bearing and tidal current in the
relative direction.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-37
Section 2
Name and Function of Each Unit
2.3.1.8 Conning
The Conning shows simple conning information.
Click [Conning] on the "Page Selection" dialog box.
When [Conning] is not displayed, drag the scroll bar downwards.
Scroll bar
The [Conning] window is displayed.
The [Conning] window consists of four blocks, and each block has a window switching button.
Section 2
Name and Function of Each Unit
2-38
1
Click a window switching button to show the [Contents Selection] window.
Click the [Depth] or [ROT] (Rate Of Turn) button.
On the [Conning] window, the [Depth] information or [ROT] information is shown.
In this example, the [Depth] information is shown at top left, and the [ROT] information is shown
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
at top right.
APP B
2-39
Section 2
Name and Function of Each Unit
2.3.2 Information reference windows
By clicking on the buttons in the window, the contents that are displayed in the window can be
switched.
[AIS MSG Tray]
button
[NAVTEX]
button
[Active Alert]
button [Alert History] [AIS] button
button
Information reference related windows are listed below.
Button
Displayed content
Related section
[AIS MSG Tray]
AIS message tray
2.3.2.2 AIS MSG Tray
[NAVTEX]
(Displayed only
when NAVTEX is
installed)
NAVTEX message
2.3.2.3 NAVTEX
[Active Alert]
Active alert that occurred in the equipment
2.3.2.4 Active Alert
[Alert History]
Alert history that occurred in the equipment
2.3.2.5 Alert History
[AIS]
Own ship’s AIS information
2.3.2.6 AIS
Section 2
Name and Function of Each Unit
2-40
1
When unread messages exist
The number of unread messages is displayed on the [AIS MSG Tray] button as a badge.
2.3.2.1 Switching between a standard window and an extended
window
The information reference window can be switched to a standard window or an extended window.
To switch to an extended window, click on the List extension button.
To switch to a standard window, click on the List Standard button.
List extension
button
List
standard
button
[Example of extended window]
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-41
Section 2
Name and Function of Each Unit
[Example of standard window]
A list screen and a detail screen are available for the standard window.
To switch to the detail screen: Click on the [Detail] button.
To switch to the list screen: Click on the [List] button.
Scroll bar
[Detail] button
[List] button
Scroll bar
When the display contents overlap the top, bottom, left, or right side of the screen, a scroll bar is
displayed.
By dragging the scroll bar, the overlapped section can be displayed.
Memo
A standard window is displayed at the initial display.
When the RADAR transmission status is Transmit in RADAR mode, the extended window cannot
be displayed.
Section 2
Name and Function of Each Unit
2-42
1
2.3.2.2 AIS MSG Tray
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
AIS messages are displayed.
For the details of the AIS message tray, refer to "6.11 AIS Message Tray".
APP A
APP B
2-43
Section 2
Name and Function of Each Unit
2.3.2.3 NAVTEX
The NAVTEX message is displayed.
[1]
[2]
[1] NAVTEX message list
NAVTEX messages are listed. When a message line is clicked on, the details are displayed in “(2)
Message details”.
(a)
(b)
(c)
(d)
(a) Date Received
Displays a message received time.
(b) Station ID
Displays the message transmission source base station ID (A to Z).
Section 2
Name and Function of Each Unit
2-44
1
(c) Message ID
Displays the message ID (A to Z).
(d) Disp check box
When this check box is checked, the symbol is displayed.
Sorting a message list
When any of the items in the title line is clicked on, the messages are sorted based on the item.
[2] Message details
(a)
(b)
(c)
(d)
(a) Station ID
Displays the message transmission source base station ID (A to Z) and the name.
(b) Message ID
Displays the message ID and name.
(c) Expiration Date
Set the expiration date of the message.
•
When the calendar icon
is clicked on, a calendar picker is displayed. Set the expiration
date by using the calendar picker.
•
The color of the Expiration Date changes for the expired message.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
(d) NAVTEX Message
APP B
A message is displayed.
2-45
Section 2
Name and Function of Each Unit
2.3.2.4 Active Alert
This window displays active alerts that occurred in this equipment.
For the details, refer to "3.7.4 Displaying alert list and alert history".
Section 2
Name and Function of Each Unit
2-46
1
2.3.2.5 Alert History
This window displays the history of alerts that occurred in this equipment.
For the details, refer to "3.7.4 Displaying alert list and alert history".
Memo
The Alert History screen is displayed under the extended window only. A standard window is not
available.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-47
Section 2
Name and Function of Each Unit
2.3.2.6 AIS
This window displays AIS information.
The AIS window includes the "Own Ship AIS Data" window that displays the AIS information of the own
ship and "Last Lost AIS Target" window that displays the information of the last AIS target that is lost.
When the [Own Ship AIS Data] button is clicked on, the
Own Ship AIS Data window is displayed.
When the [Last Lost AIS Target] button is clicked on, the
information window of the last lost AIS target is displayed.
Own Ship AIS Data window
Static information that may be changed
at navigation
Ship’s specific
static information
Dynamic information
For the details, refer to "6.15 Confirming Own Ship's AIS Information".
Section 2
Name and Function of Each Unit
2-48
1
Window of the information of the last lost AIS target
Static information that may be changed
at navigation
Ship’s specific
static information
Dynamic information
For the details, refer to "6.16 Displaying the Last Lost AIS Target".
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-49
Section 2
Name and Function of Each Unit
2.4
Names and Main Functions of Each
Section of the RADAR Screen
This section describes the names and the main functions of each section of the RADAR screen.
Refer to "2.4.1 Presentation and
mode information".
Refer to "2.4.3 Radar
system information".
Refer to "2.4.5 Other ship
information".
Refer to "2.4.2 Radar signal
Refer to "2.4.4 Own track information".
information".
Refer to "2.4.6 Symbols inside of PPI".
Section 2
Name and Function of Each Unit
2-50
2.4.1 Presentation and mode information
Range scale combo box
Motion mode combo box
Bearing mode combo box
For the details, refer to "5.3.2
Changing the observation
range".
For the details, refer to "5.4.6
Setting a motion mode".
For the details, refer to "5.4.5 Setting
the azimuth mode".
Set the observation range.
Set the motion mode.
Set the bearing mode.
Stabilization mode combo box
Set the stabilization mode.
For the details, refer to "5.4.7 Setting the
Stabilization Mode".
Range rings display button
Use this button to switch range rings to
On/Off.
[In] (Zoom In) button
Whenever this button is
clicked on, the screen image
is zoomed in by one level
from the current range scale.
When this button is held
down, the image is zoomed
in continuously.
[Out] (Zoom Out) button
Whenever this button is
clicked on, the screen image
is zoomed out by one level
from the current range scale.
When this button is held
down, the image is zoomed
out continuously.
For the details, refer to "4.4 Using the
Range Rings".
[Off Center] button
Use this button to set Off Center to
On/Off for the display position of the
own ship’s position (CCRP).
For the details, refer to "5.4.8 Moving
own ship’s display position (Off
Center)".
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-51
Section 2
Name and Function of Each Unit
2.4.2 Radar signal information
Observation Scene Selection button
This button sets an observation scene
For the details, refer to "5.3.7 Adjusting to optimal
images (Selection of observation scenes)".
RADAR signal processing setting button
This button sets RADAR signal processing. When
this button is clicked on, a setting dialog box
appears.
[1]
[2]
[1]
[2]
[3]
[3]
[1] Reception sensitivity adjustment
The reception sensitivity can be adjusted.
For the details, refer to "5.3.4 Adjusting
gain".
[2] Sea clutter adjustment
The sea clutter rejection level can be
adjusted.
For the details, refer to "5.3.5 Rejecting
sea clutter (Sea)".
[3] Rain and snow clutter adjustment
The rain and snow clutter rejection level
can be adjusted.
For the details, refer to "5.3.6 Rejecting
rain/snow clutter".
Section 2
Name and Function of Each Unit
[4]
[5]
[1] [X2 (Zoom)] button
When this button is clicked on, the double scale
zoom function is switched to On/Off.
For the details, refer to "5.4.10 Doubling the size of
radar image".
[2] [IR] combo box
This setting is enabled to set a radar interference
rejection function from the list
For the details, refer to "5.4.1 Interference
Rejection (IR Function)".
[3] [Target Enhance] combo box
This setting is enabled to set a target enhancement
function from the list
For the details, refer to "5.4.3 Enhancing targets".
[4] [Echo Process] combo box
This setting is enabled to set a video processing
function from the list
For the details, refer to "5.4.4 Using video
processing (Echo Process)".
[5] [Chirp Channel] combo box
This setting is enabled to set the Chirp Channel
function by selecting On or Off from the combo box.
*The Chirp Channel function can be set only when
a small solid -state radar antenna is connected. By
changing the transmission central frequency
(channel) of Q0N (Chirp wave: Frequency
modulation pulse) that is used for pulse
compression, interferences can be controlled.
2-52
1
2.4.3 Radar system information
On this window, verify, adjust, and set a signal tuning status.
The display varies according to the radar antenna type.
Confirmation and
adjustment of tuning
Standby/transmission
switching button
This button checks the tuning
status and slightly adjusts.
For the details, refer to "5.3.3
Adjusting tune".
Whenever this button is
clicked on, the mode is
switched to "Standby" or
"Transmit". When the power
for this equipment is turned
on, "Preheat" is displayed on
this button.
For the display change at
power ON, refer to Step 3 in
the section "5.2.1 Powering
on and starting"
Transmission pulse
length switching button
This button switches a
transmission pulse length.
For the details, refer to "5.4.2
Changing the transmitter
pulse length".
Magnetron radar is connected
as the radar antenna
Transmission band
display
Control status and control antenna display at inter-switch
connection
When this button is clicked on, the interswitch switching window is displayed.
For the details of the inter-switch, refer to "Appendix C Setting the Interswitch".
This button displays the
transmission band that is
currently used (X-Band or
S-Band).
Transmission pulse length switching button
This button switches a transmission pulse length.
For the details, refer to "5.4.2 Changing the
transmitter pulse length".
Tuning status display
When the
standby/transmission
switching button is set to
"Preheat" or "Standby", no
information is displayed.
When the
standby/transmission
switching button is set to
"Transmit", "Tuning OK" is
displayed.
Control status and
control antenna display at
inter-switch connection
Transmission pulse
length switching
button
This button switches a
transmission pulse length.
For the details, refer to
"5.4.2 Changing the
transmitter pulse length".
Transmission band
display
Solid state radar is connected
as the radar antenna.
This button displays the
transmission band that is
currently used (S-Band).
When this button is clicked on,
the inter-switch switching
window is displayed.
For the details of the
inter-switch, refer to "Appendix
C Setting the Interswitch".
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
2-53
Section 2
Name and Function of Each Unit

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : PCUser
Create Date                     : 2015:10:15 15:18:15-07:00
Modify Date                     : 2015:10:15 15:18:22-07:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2015:10:15 15:18:22-07:00
Creator Tool                    : Word 用 Acrobat PDFMaker 11
Format                          : application/pdf
Creator                         : PCUser
Document ID                     : uuid:904705f7-b872-481f-a181-98d6ef151d60
Instance ID                     : uuid:95e4c180-8c5a-424d-b72a-8f0aeeac3eca
Producer                        : Adobe PDF Library 11.0
Page Count                      : 53
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CKENKE2632

Navigation menu