NCR RSD Atlanta 7710GA2 Electronic Pricing Transmitter User Manual Appedix C
NCR Corporation, RSD - Atlanta Electronic Pricing Transmitter Users Manual Appedix C
Contents
- 1. Users Manual Cover
- 2. Users Manual Front
- 3. Users Manual Glossary
- 4. Users Manual Index
- 5. Users Manual Appendix A
- 6. Users Manual Appendix B
- 7. Users Manual Appedix C
- 8. Users Manual Appedix D
- 9. Chapter 1
- 10. Chapter 2
- 11. Chapter 3
- 12. Chapter 4
- 13. Chapter 5
- 14. Chapter 6
- 15. Chapter 7
- 16. Chapter 8
- 17. Chapter 9
- 18. Chapter 10
- 19. Chapter 11
- 20. Chapter 12
- 21. Chapter 13
Users Manual Appedix C

![C-2 Configuration FilesDecisioNet Windows NT Configuration FilesThe following sections show the default configuration files in aDecisioNet Windows NT system.Base Software Configuration File (basesw.cfg)The following is an example basesw.cfg file. It contains an explanationof each parameter in the file. Some parameters are set using the EPLAdministrator configuration screens. Use an editor to set theCBSCOMM_PORT parameter from the DOS system prompt.Caution: Many of the parameters are commented out with a # symbolin the first character position. The values shown are system defaultsused by various DecisioNet programs and utilities. They are intendedfor reference purposes only, and should NOT be edited or changedexcept by trained NCR personnel.##################################################COMMON#################################################"EPL_TYPE", 1##################################################CBS MANAGER##################################################When this value is non zero, the CBS Manager will retry# with a greater batch size when current batch size is# smaller. [0]#"EPLCOMM_RETRYPLUS,0#Uplink channels for time slot 1/4/7/10,2/5/8/11,3/6/9/12# (1-5) [2,4,5]"EPLCOMM_UPLINKCHANNEL","2,4,5"# Batch size of group 0 for pooling messages# (1,2,4,8,16) [1]"EPLCOMM_BATGRP0",1# Batch size of group 1 for pooling messages# (1,2,4,8,16) [1]"EPLCOMM_BATGRP1",1](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-2.png)
![Configuration Files C-3#Specifies the time slots that are used for downlink# messages to an EPL. They are assigned as follows:# 0: 1,2,3,7,8,9# 1: 4,5,6,10,11,12# 2: 1,2,3# 3: 4,5,6# 4: 7,8,9# 5: 10,11,12# (0-5) [0]#"TIMESLOT_GROUP",0#Specifies store identification# Mandatory field"STORE_ID", 100#Specifies RS-232 device name# Mandatory."CBSCOMM_PORT", "COM1"#Communication port speed# (9600) [9600]"CBSCOMM_SPEED", 9600#Addresses of the connected CBS's. These addresses are# comma separated.# (0-19) [0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19]"CBS_ADDRESS", "00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19"# Maximum number of attempts to send a request to an EPL# in the case when the batch size is one. In the case of# pooling, this paramter is ignored and the parameter# EPLCOMM_RETRYPLUS is in effect. (0-15) [3]"EPLCOMM_MAXRETRY",3#Maximum permissible lag of master tick value. A value of# 255 means automatically correct the TOD. If the batch size# for group 0 or 1 is greater that this parameter plus 1, the# actual lag time will the batch group size minus 1. (0-255) [4]"CBS_MAXTODLAG", 004#Range of frequencies used to load the CBS frequency hopping tables# (0,283) ["0,283"]#"CBS_FREQRANGE","0,283"#Threshhold of noise level for removing frequency (multiplier of# standard deviation of noise level). This value is floating# point. (0.0-9.94) [2.0]#"CBS_FREQNOISETHRESHHOLD","2.0"#Standard deviation multiplier used for calculating minimum uplink# signal strength. If this value is zero, the CBS Manager will not](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-3.png)
![C-4 Configuration Files# optimize threshold values [3.7]#"OPTFACTOR_SIGNALTHRESHOLD","3.7"#Standard deviation multiplier used for calculating maximum# amount of noise on an uplink [3.0]#"OPTFACTOR_NOISETHRESHOLD","3.0"#The period within which the Data Scheduler needs to send a LIVE# notice to the CBS Manager. (0-255) [15]"SCHEDABSENCE_MAXTIME",025#Number of seconds to wait in between sending pseudo uplink messages# (1-59) [10]# PSEUDOUPLINK_INTERAL,10##################################################DATA SCHEDULER##################################################Interval of automatic retry (1-255) [10]"SCH_RETRYINTERVAL",001#Minimum number of send errors necessary for a# request with the ES_WARNING bit set to return# a request in a Get Sendstatus call (1-255) [3]"SCH_WARNTHRESHOLD",001#Automatic retry period for request without due date/time# and implicitly commited requests (1-255) [60]"SCH_RETRYPERIOD",010#Delay time after primary scheduled date/time for sending# secondary scheduled request (0-255) [10]"SCH_POSTPRIMTOD",002#Margin time to give up retrying before scheduled date/time# (0-255) [60]"SCH_PRESCHEDTOD",002#A non-zero value tells Data Scheduler to send scheduled sales# promotion set function at the due time (without utilizing# the TOD in an EPL. [1]#"SCH_TIMEDSALESPROMMODE",1#Default size of the spool file if it does not exist# 1-65536 [20000]"SCH_DEFAULTSPOOLSIZE", 10000#Range of serial #'s corresponding to tags where the# CBS Manager must send a downlink burst for loading# data into display register #2 twice"EPLPTF_A", "10000, 15000"](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-4.png)
![Configuration Files C-5#Range of serial #'s corresponding to tags where sumcheck# test for EPL error status turns on the H/W error bit.# Price update message for display register #2 and #3# affects event time"EPLPTF_B", "10000, 15000""EPLPTF_C", "10000, 15000""EPLPTF_D", "10000, 15000"#Determines whether schaudit.log.<dayofweek> log#files will be created in the data directory. [YES]"SCH_ENABLE_AUDITLOGGING","YES"##################################################TABLE MANAGER##################################################Determines whether tblaudit.log.<dayofweek> log#files will be created in the data directory. [YES]"TBL_ENABLE_AUDITLOGGING","YES"##################################################BEDCHECK##################################################Maximum number of times to retry (0-10) [3]"BED_MAXRETRY", 0#Length of time (minutes) to wait in between retries# (1-255) [1]#"BED_RETRYINTERVAL",1#If non-zero value, then a sumcheck error will enforce# EPL hardware error#"BED_ENFORCEHWERR",0#Default size of bedcheck log#"BED_DEFAULTLOGSIZE",5000##################################################LABEL DATA MANAGER##################################################An integer value which designates the elapsed time (seconds) between#accesses of the PLU File to determine the descriptions which have changed# [0]"LDM_GRANULARITY",300#Designates the number of EPL records processes at one time when description#changes are checked. [100]"LDM_RECORDS_NUMBER",100](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-5.png)
![C-6 Configuration Files##################################################IPC##################################################If set to YES then debug messages from the IPC code will be#displayed. [NO]#"ES_ENABLEIPCTRACING","NO"#YES to enable sockets IPC. Use for communication between# heterogeneous operating systems. Don't use with WIN95. [NO]#"ES_ENABLESOCKETS","NO"#If sockets IPC is enabled, the number of seconds to wait for a# server connection [3]#"ES_SOCKETCONNECTWAIT", 3#If sockets IPC is enabled, the number of times to retry sending a# request to a server. [3]#"ES_SOCKETSENDRETRIES",3#If sockets IPC is enabled, the number of times to a server will attempt# to read a request from a client [3]#"ES_SOCKETREADRETRIES",3#If socket or rpc IPC is enabled, this specifies the address where the# server programs are running [127.0.0.1]#"ES_SERVERIPADDRESS","127.0.0.1"#YES to enable RPC IPC. Set to YES to do networking between two WIN32#operating systems (i.e. WIN95/WINNT) [NO]#"ES_ENABLERPC", "NO"#YES to enable memory-mapped file IPC. This is the default. Set to NO# if using RPC or SOCKETS [YES]#"ES_ENABLEMEMFILES","YES"#The number of seconds a client should wait for a response from a server. [60]#"ES_IPCRESPONSEWAIT",60##################################################FAILURE DETECTION AND ANALYSIS#################################################"SVFDA_CMDLINE", "-m30"#FD&A will log an error if a CBS's minsignal/maxnoise exceeds these# parameter values"FDA_MINSIGNAL", 85"FDA_MAXNOISE", 80#These parameters are set by ESADMIN, and define how power supplies# are configured"POWERA_ADDRESS"](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-6.png)








![Configuration Files C-15Log Monitor Configuration File (logmon.cfg)The Log Monitor configuration file contains the information displayedin the Log Monitor modal dialog box and the Log Monitor report. Thefile can be edited to include site-specific error and corrective actioninformation. Refer to Appendix D for details on customizing the LogMonitor functionality.# The EPL Log Monitor generates alerts based upon the contents of this# configuration file. The Log Monitor Configuration file format is as follows:## [SOURCE]# SEVERITY, "Message Text"# SEVERITY, "Message Text"# ...## where SOURCE is the name of any process that logs error messages to the EPL# error log, and SEVERITY is any one of the following: SUCCESS, INFORMATION,# WARNING, or ERROR.## ERRNUM, "Message Text"## where ERRNUM is the error number associated with the corrective action message# that follows.#[ESCBSMGR]ERROR, "EPL CBS Manager logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESLOGGER]ERROR, "EPL Logger logged errors that are causing serious EPL software problems.Immediate investigation of these problems is recommended. Call NCR fieldpersonnel for assistance."[ESSCHED]ERROR, "EPL Scheduler logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESTBLMGR]ERROR, "EPL Table Manager logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESEXTDI]](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-15.png)
![C-16 Configuration FilesERROR, "EPL External Data Interface logged errors that could cause serious EPLsystem problems. Immediate investigation of these problems is recommended."[ESBRIDGE]ERROR, "EPL Bridge logged errors that are causing serious EPL software problems.Immediate investigation of these problems is recommended. Call NCR fieldpersonnel for assistance."[ESPLURDR]ERROR, "EPL PLU Reader logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESPLUXTRC]ERROR, "EPL PLU Extractor logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESBEDCHK]ERROR, "EPL Bedcheck logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESPRCVRF]ERROR, "EPL Price Verifier logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESSPRCVRF]ERROR, "EPL Sales Price Verifier logged errors that are causing serious EPLsoftware problems. Immediate investigation of these problems is recommended.Call NCR field personnel for assistance."[ESPRCCHK]ERROR, "EPL Price Checker logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESPROMOVRF]ERROR, "EPL Promotional Verifier logged errors that are causing serious EPLsoftware problems. Immediate investigation of these problems is recommended.Call NCR field personnel for assistance."[ESLOGMON]ERROR, "EPL Log Monitor logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESSTAT]ERROR, "EPL Status Tag Manager logged errors that are causing serious EPLsoftware problems. Immediate investigation of these problems is recommended.](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-16.png)
![Configuration Files C-17Call NCR field personnel for assistance."[ESFDA]WARNING, "EPL Failure Detection and Anaysis detected warnings that may lead toEPL system problems later. Investigation of these problems is recommended. CallNCR field personnel for assistance."ERROR, "EPL Failure Detection and Analysis detected errors that are causingserious EPL system problems. Immediate investigation of these problems isrecommended. Call NCR field personnel for assistance."[ESAMS]ERROR, "EPL Automated Messaging System logged errors that could cause serious EPLsystem problems. Immediate investigation of these problems is recommended."1000, "Invalid parameter data error message indicates that an invalid commandline option was specified. Review usage information and restart.1103, "The system is running low on memory. Check using 'sar -r' for memoryactivity."1152, "Unable to obtain semaphore. Check the kernel parameters or tune thesemaphore count."1200, "The EPL Table has been closed. Reopen it using 'tbltest'."1209, "The EPL table has become corrupt. Call customer support."1300, "The communication to the CBS is closed. Reopen the communication usingthe EPL administration utility."1303, "Unable to communicate with the CBS. Run diagnostic tests on the CBS's."1304, "The master CBS link is down. Verify that the CBS's are functioningproperly."1310, "Unable to communicate with the EPL. Check to see if the EPL exists and isin within RF range."1372, "The Master CBS unexpectedly closed EPL communications. A fault has beendeted in the communication link between the CBS Manager and the Master CBS. Ifthe problem persists, call customer support."1600, "The Data Scheduler is closed. Open the data scheduler."1607, "The Data Scheduler files are corrupt. If problem persists, call customersupport."1624, "The Data Scheduler was unable to create the spool file. Check thepermissions of the file 'spool.dat' and verify the disk space."1631, "Unable to communicate with the EPL before due time. Check to see if theEPL exists and is in RF range."1682, "Unable to communicate with the EPL before due time. Check to see if theEPL exists and is in RF range."1683, "The Data Scheduler was unable to update the spool file. Check thepermissions of the file 'spool.dat' and verify the disk space."1684, "The Data Scheduler was unable to add records to the spool file. Check thepermissions of the file 'spool.dat' and verify the disk space."1686, "The CBS did not process the send request. Possibly, the message sent tothe CBS manager from the scheduler has invalid data. Check the Data Schedulerlog"1690, "The Data Scheduler is closed. Open the data scheduler."1808, "The PLU file cannot be opened. Call customer support."2102, "Unable to communicate with the PLU Reader. Check to see if the PLU reader](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-17.png)

![Configuration Files C-19configuration problem. Use the ESADMIN base config menu option to configureantenna C.2719, "Receive antenna D off error message identifies a problem with receiveantenna D or CBS receive antenna D port. The error may also occur when receiveantenna D is improperly configured using ESADMIN.2720, "Unconfigured receive antenna D error message indicates a hardwareconfiguration problem. Use the ESADMIN base config menu option to configureantenna D.2721, "Signal level threshold error message indicates a CBS Manager thresholdingproblem. Ambient noise in the environment is causing EPL communication problems.Call your NCR Field Engineer immediately.2722, "Noise level threshold error message indicates a CBS Manager thresholdingproblem. Ambient noise in the environment is causing EPL communication problems.Call your NCR Field Engineer immediately.2803, "Log Monitor not configured as interactive error indicates that the LogMonitor service was not configured properly. Click on the "startup" button onthe services dialog box, and enable the "allow service to interact with desktop"option.3000, "Unable to start as service error message indicates that the Windows NTservice could not be started. Use the Windows NT service dialog box to start theservice manually.3005, "Unable to communicate with EPL Table Manager error message indicates thatthe Table Manager was not started properly. Stop and restart the Table Manager.If the problem persists, stop and restart all base software components."3006, "Unable to communicate with PLU Reader error message indicates that the PLUReader was not started properly. Stop and restart the PLU Reader. If theproblem persists, stop and restart all base software components."3007, "Unable to communicate with Data Scheduler error message indicates that theData Scheduler was not started properly. Stop and restart the Data Scheduler.If the problem persists, stop and restart all base software components."3008, "Unable to fork a child process error message indicates that the user isout of resources. Tune system and user parameters.3009, "Unable to open a new virtual terminal error message indicates that thesystem is out of resources. Tune system parameters.6115, "The price is too large to be displayed on the tag."7707, "Unable to open the master IDX [USERIDX.TXT] file. - Defaults will beused."8501, "Invalid or non-existent AMS Configuration file."9003, "Unable to open the PLU file. Check to see if the ACS system is running."](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-19.png)
![C-20 Configuration FilesEPL Backup Information File (eplbackup.ini)This file identifies which files are backed up when the EPL BackupUtility is run. Wildcard (*) entries are used. Refer to the \epl\data\directory following installation to determine which files are includedin the backup. Additional files may be added.[Backup Files]C:\epl\data\esmeasur.tbl=C:\epl\data\labeldf.*=C:\epl\data\espasswd.*=C:\epl\data\EBATINF.*=C:\epl\data\EBATESL.*=C:\epl\data\esitem.* =C:\epl\data\*.tly=C:\epl\data\*.cfg=C:\epl\data\*.tbl=C:\epl\data\*.log=C:\epl\data\schaudit.*C:\epl\data\tblaudit.*C:\epl\data\eplbackup.ini=](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-20.png)
![Configuration Files C-21EPL Status Tag Manager Configuration File (status.cfg)The Status Tag Manager uses this file to display system statusinformation on EPLs. Refer to Appendix D for details about using thisfile with the Status Tag Manager.# EPL Status Tag Manager configuration file## Each entry in this configuration file defines a message to be displayed# on a SmarTalker status tag. A filename may also be defined that can be# used to dynamically change the messages displayed on the status tag.# The format of each entry should look like this:## [SYSTEM]# MODE, I|S|A# FILENAME, "pathname"# EPLID, eplid1 eplid2 ...# DEFAULT_MSG, "MESSAGE"# DEFAULT_UPMSG, "MESSAGE"# DEFAULT_DOWNMSG, "MESSAGE"# IDLETIME, seconds## SYSTEM defines the name of the system for which the status tag is allocated.# There may be multiple entries for each system. SYSTEM should be defined as# "EPL SYSTEM" for all EPL system status tags that use MODE A.# MODE defines one of three modes of operation: (I)mmediate, (S)cheduled, or# (A)utomatic. Immediate mode forces an immediate display of the desired# message. Scheduled mode forces the EPL controller to wait for IDLETIME# seconds before sending the message. Automatic mode updates the status tag# immediately, but displays DEFAULT_DOWNMSG when IDLETIME expires.# FILENAME defines the name of the STAT file that is used to pass new messages# to be displayed on the status tag. FILENAME must be a fully qualified# pathname. (STAT file contents must be ASCII, and only the first 8 characters# are displayed in the status tag's LCD window. The "^" character may be used# to embed descriptor escape sequences.)# EPLID defines the EPLIDs that correspond to the status tags that the user# wishes to allocate to SYSTEM. Multiple EPLIDs may be defined. Each EPLID# must be unique, and must not be allocated in the EPL Table.# DEFAULT_UPMSG defines the message that the status tag displays when the# system's status is good.# DEFAULT_DOWNMSG defines the message that the status tag displays when the# system's status is bad.# DEFAULT_MSG defines a message that is always displayed regardless of the# system's status. The "^" character may be used to embed escape sequences.# IDLETIME is valid for MODES A and S. IDLETIME defines the delay time (in# seconds) beween the time a message is sent to a status tag and the time the# tag's LCD changes.](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-21.png)
![C-22 Configuration Files[EPL SYSTEM]MODE, IEPLID,DEFAULT_MSG, "EPL"[EPL SYSTEM]MODE, IEPLID,DEFAULT_MSG, "SYSTEM"[EPL SYSTEM]MODE, AEPLID,DEFAULT_UPMSG, "HW OK"DEFAULT_DOWNMSG, "HW FAIL"IDLETIME, 300[EPL SYSTEM]MODE, IFILENAME, "c:\epl\data\STATMOD.001EPLID,DEFAULT_MSG, "SW OK"](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-22.png)
![Configuration Files C-23DecisioNet UNIX Configuration FilesThe following sections show the default configuration files in aDecisioNet UNIX system.Base Software Configuration File (basesw.cfg)The following is an example basesw.cfg file. It contains an explanationof each parameter in the file. Some parameters are set using the EPLAdministrator configuration screens. Use an editor to set theCBSCOMM_PORT parameter from the DOS system prompt.Caution: Many of these parameters are commented out with a #symbol in the first character position. The values shown are systemdefaults used by various DecisioNet programs and utilities. They areintended for reference purposes only, and should NOT be edited orchanged except by trained NCR personnel.##################################################COMMON#################################################"EPL_TYPE", 1##################################################CBS MANAGER##################################################When this value is non zero, the CBS Manager will retry# with a greater batch size when current batch size is# smaller. [0]#"EPLCOMM_RETRYPLUS,0#Uplink channels for time slot 1/4/7/10,2/5/8/11,3/6/9/12# (1-5) [2,4,5]"EPLCOMM_UPLINKCHANNEL","2,4,5"# Batch size of group 0 for pooling messages# (1,2,4,8,16) [1]"EPLCOMM_BATGRP0",1# Batch size of group 1 for pooling messages# (1,2,4,8,16) [1]"EPLCOMM_BATGRP1",1](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-23.png)
![C-24 Configuration Files#Specifies the time slots that are used for downlink# messages to an EPL. They are assigned as follows:# 0: 1,2,3,7,8,9# 1: 4,5,6,10,11,12# 2: 1,2,3# 3: 4,5,6# 4: 7,8,9# 5: 10,11,12# (0-5) [0]#"TIMESLOT_GROUP",0#Specifies store identification# Mandatory field"STORE_ID", 100#Specifies RS-232 device name# Mandatory."CBSCOMM_PORT", "COM1"#Communication port speed# (9600) [9600]"CBSCOMM_SPEED", 9600#Addresses of the connected CBS's. These addresses are# comma separated.# (0-19) [0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19]"CBS_ADDRESS", "00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19"# Maximum number of attempts to send a request to an EPL# in the case when the batch size is one. In the case of# pooling, this paramter is ignored and the parameter# EPLCOMM_RETRYPLUS is in effect. (0-15) [3]"EPLCOMM_MAXRETRY",3#Maximum permissible lag of master tick value. A value of# 255 means automatically correct the TOD. If the batch size# for group 0 or 1 is greater that this parameter plus 1, the# actual lag time will the batch group size minus 1. (0-255) [4]"CBS_MAXTODLAG", 004#Range of frequencies used to load the CBS frequency hopping tables# (0,283) ["0,283"]#"CBS_FREQRANGE","0,283"#Threshhold of noise level for removing frequency (multiplier of# standard deviation of noise level). This value is floating# point. (0.0-9.94) [2.0]#"CBS_FREQNOISETHRESHHOLD","2.0"](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-24.png)
![Configuration Files C-25#Standard deviation multiplier used for calculating minimum uplink# signal strength. If this value is zero, the CBS Manager will not# optimize threshold values [3.7]#"OPTFACTOR_SIGNALTHRESHOLD","3.7"#Standard deviation multiplier used for calculating maximum# amount of noise on an uplink [3.0]#"OPTFACTOR_NOISETHRESHOLD","3.0"#The period within which the Data Scheduler needs to send a LIVE# notice to the CBS Manager. (0-255) [15]"SCHEDABSENCE_MAXTIME",025#Number of seconds to wait in between sending pseudo uplink messages# (1-59) [10]# PSEUDOUPLINK_INTERVAL,10##################################################DATA SCHEDULER##################################################Interval of automatic retry (1-255) [10]"SCH_RETRYINTERVAL",001#Minimum number of send errors necessary for a# request with the ES_WARNING bit set to return# a request in a Get Sendstatus call (1-255) [3]"SCH_WARNTHRESHOLD",001#Automatic retry period for request without due date/time# and implicitly commited requests (1-255) [60]"SCH_RETRYPERIOD",010#Delay time after primary scheduled date/time for sending# secondary scheduled request (0-255) [10]"SCH_POSTPRIMTOD",002#Margin time to give up retrying before scheduled date/time# (0-255) [60]"SCH_PRESCHEDTOD",002#A non-zero value tells Data Scheduler to send scheduled sales# promotion set function at the due time (without utilizing# the TOD in an EPL. [1]#"SCH_TIMEDSALESPROMMODE",1#Default size of the spool file if it does not exist# 1-65536 [20000]"SCH_DEFAULTSPOOLSIZE", 10000](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-25.png)
![C-26 Configuration Files#Range of serial #'s corresponding to tags where the# CBS Manager must send a downlink burst for loading# data into display register #2 twice"EPLPTF_A", "10000, 15000"#Range of serial #'s corresponding to tags where sumcheck# test for EPL error status turns on the H/W error bit.# Price update message for display register #2 and #3# affects event time"EPLPTF_B", "10000, 15000""EPLPTF_C", "10000, 15000""EPLPTF_D", "10000, 15000"#Determines whether schaudit.log.<dayofweek> log#files will be created in the data directory. [YES]"SCH_ENABLE_AUDITLOGGING","YES"##################################################TABLE MANAGER##################################################Determines whether tblaudit.log.<dayofweek> log#files will be created in the data directory. [YES]"TBL_ENABLE_AUDITLOGGING","YES"##################################################BEDCHECK##################################################Maximum number of times to retry (0-10) [3]"BED_MAXRETRY", 0#Length of time (minutes) to wait in between retries# (1-255) [1]#"BED_RETRYINTERVAL",1#If non-zero value, then a sumcheck error will enforce# EPL hardware error#"BED_ENFORCEHWERR",0#Default size of bedcheck log#"BED_DEFAULTLOGSIZE",5000##################################################LABEL DATA MANAGER##################################################An integer value which designates the elapsed time (seconds) between#accesses of the PLU File to determine the descriptions which have changed# [0]"LDM_GRANULARITY",300](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-26.png)
![Configuration Files C-27#Designates the number of EPL records processes at one time when description#changes are checked. [100]"LDM_RECORDS_NUMBER",100##################################################IPC##################################################If set to YES then debug messages from the IPC code will be#displayed. [NO]#"ES_ENABLEIPCTRACING","NO"#YES to enable sockets IPC. Use for communication between# heterogeneous operating systems. Don't use with WIN95. [NO]#"ES_ENABLESOCKETS","NO"#If sockets IPC is enabled, the number of seconds to wait for a# server connection [3]#"ES_SOCKETCONNECTWAIT", 3#If sockets IPC is enabled, the number of times to retry sending a# request to a server. [3]#"ES_SOCKETSENDRETRIES",3#If sockets IPC is enabled, the number of times to a server will attempt# to read a request from a client [3]#"ES_SOCKETREADRETRIES",3#If socket or rpc IPC is enabled, this specifies the address where the# server programs are running [127.0.0.1]#"ES_SERVERIPADDRESS","127.0.0.1"#YES to enable RPC IPC. Set to YES to do networking between two WIN32#operating systems (i.e. WIN95/WINNT) [NO]#"ES_ENABLERPC", "NO"#YES to enable memory-mapped file IPC. This is the default. Set to NO# if using RPC or SOCKETS [YES]#"ES_ENABLEMEMFILES","YES"#The number of seconds a client should wait for a response from a server. [60]#"ES_IPCRESPONSEWAIT",60##################################################FAILURE DETECTION AND ANALYSIS#################################################"SVFDA_CMDLINE", "-m30"#FD&A will log an error if a CBS's minsignal/maxnoise exceeds these# parameter values"FDA_MINSIGNAL", 85](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-27.png)





![Configuration Files C-33#RANDOM_WEIGHT_PRICE_DISPLAY,0## Do items stored in the POS PLU file contain a check digit ornot?# 0 - Items don't include a check digit# 1 - Items include a check digit#PLU_EAN_CHECK_DIGIT,0## When decimal place is less than 2 for the EURO tag, thisparameter# determines whether to display a space in the second placeafter the decimal# position or display unit price to two decimal positions# 0 - Display unit price to two decimal positions# 1 - Display a space#MAX_ONE_UP_DEC_POS_FOR_CENTS, 0## Whether or not the EURO symbol is displayed or not.#EURO_PRICING, 0## Filename for reports#EPL_TABLE_RPT_FILENAME, epltable.rptBEDCHECK_LOG_RPT_FILENAME, esbedchk.rptSAVE_SYSERROR_LOG_RPT_FILENAME, error.rptSAVE_SENDLOG_RPT_FILENAME, send.rptSAVE_AUDITLOG_RPT_FILENAME, audit.rptSAVE_ADM_SYSERROR_LOG_RPT_FILENAME, error.rptSAVE_ADM_SENDLOG_RPT_FILENAME, send.rptSAVE_ADM_AUDITLOG_RPT_FILENAME, audit.rptSAVE_ADM_FDA_RPT_FILENAME, esfda.rptCBS Parameter File (cbsparam.tbl)The CBS Parameter file contains parameters that specify the CBSManager’s hopping frequencies, and the DecisioNet System’sminimum signal and maximum noise settings.[00]"HOPSET", 37, 76, 247, 93, 211, 164, 130, 239, 176, 174, 26,136, 198, 195, 84, 73, 178, 261, 1, 74, 215, 179, 4, 48, 226,207, 16, 117, 270, 113, 122, 173, 163, 274, 192, 62, 283, 268,](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-33.png)

![Configuration Files C-35Log Monitor Configuration File (logmon.cfg)The Log Monitor configuration file contains the information displayedin the Log Monitor modal dialog box and the Log Monitor report. Thefile can be edited to include site-specific error and corrective actioninformation. Refer to Appendix D for details on customizing the LogMonitor functionality.# The EPL Log Monitor generates alerts based upon the contents of this# configuration file. The Log Monitor Configuration file format is as follows:## [SOURCE]# SEVERITY, "Message Text"# SEVERITY, "Message Text"# ...## where SOURCE is the name of any process that logs error messages to the EPL# error log, and SEVERITY is any one of the following: SUCCESS, INFORMATION,# WARNING, or ERROR.## ERRNUM, "Message Text"## where ERRNUM is the error number associated with the corrective action message# that follows.#[ESCBSMGR]ERROR, "EPL CBS Manager logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESLOGGER]ERROR, "EPL Logger logged errors that are causing serious EPL software problems.Immediate investigation of these problems is recommended. Call NCR fieldpersonnel for assistance."[ESSCHED]ERROR, "EPL Scheduler logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESTBLMGR]ERROR, "EPL Table Manager logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESEXTDI]](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-35.png)
![C-36 Configuration FilesERROR, "EPL External Data Interface logged errors that could cause serious EPLsystem problems. Immediate investigation of these problems is recommended."[ESBRIDGE]ERROR, "EPL Bridge logged errors that are causing serious EPL software problems.Immediate investigation of these problems is recommended. Call NCR fieldpersonnel for assistance."[ESPLURDR]ERROR, "EPL PLU Reader logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESPLUXTRC]ERROR, "EPL PLU Extractor logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESBEDCHK]ERROR, "EPL Bedcheck logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESPRCVRF]ERROR, "EPL Price Verifier logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESSPRCVRF]ERROR, "EPL Sales Price Verifier logged errors that are causing serious EPLsoftware problems. Immediate investigation of these problems is recommended.Call NCR field personnel for assistance."[ESPRCCHK]ERROR, "EPL Price Checker logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESPROMOVRF]ERROR, "EPL Promotional Verifier logged errors that are causing serious EPLsoftware problems. Immediate investigation of these problems is recommended.Call NCR field personnel for assistance."[ESLOGMON]ERROR, "EPL Log Monitor logged errors that are causing serious EPL softwareproblems. Immediate investigation of these problems is recommended. Call NCRfield personnel for assistance."[ESSTAT]ERROR, "EPL Status Tag Manager logged errors that are causing serious EPLsoftware problems. Immediate investigation of these problems is recommended.](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-36.png)
![Configuration Files C-37Call NCR field personnel for assistance."[ESFDA]WARNING, "EPL Failure Detection and Anaysis detected warnings that may lead toEPL system problems later. Investigation of these problems is recommended. CallNCR field personnel for assistance."ERROR, "EPL Failure Detection and Analysis detected errors that are causingserious EPL system problems. Immediate investigation of these problems isrecommended. Call NCR field personnel for assistance."[ESAMS]ERROR, "EPL Automated Messaging System logged errors that could cause serious EPLsystem problems. Immediate investigation of these problems is recommended."1000, "Invalid parameter data error message indicates that an invalid commandline option was specified. Review usage information and restart.1103, "The system is running low on memory. Check using 'sar -r' for memoryactivity."1152, "Unable to obtain semaphore. Check the kernel parameters or tune thesemaphore count."1200, "The EPL Table has been closed. Reopen it using 'tbltest'."1209, "The EPL table has become corrupt. Call customer support."1300, "The communication to the CBS is closed. Reopen the communication usingthe EPL administration utility."1303, "Unable to communicate with the CBS. Run diagnostic tests on the CBS's."1304, "The master CBS link is down. Verify that the CBS's are functioningproperly."1310, "Unable to communicate with the EPL. Check to see if the EPL exists and isin within RF range."1372, "The Master CBS unexpectedly closed EPL communications. A fault has beendeted in the communication link between the CBS Manager and the Master CBS. Ifthe problem persists, call customer support."1600, "The Data Scheduler is closed. Open the data scheduler."1607, "The Data Scheduler files are corrupt. If problem persists, call customersupport."1624, "The Data Scheduler was unable to create the spool file. Check thepermissions of the file 'spool.dat' and verify the disk space."1631, "Unable to communicate with the EPL before due time. Check to see if theEPL exists and is in RF range."1682, "Unable to communicate with the EPL before due time. Check to see if theEPL exists and is in RF range."1683, "The Data Scheduler was unable to update the spool file. Check thepermissions of the file 'spool.dat' and verify the disk space."1684, "The Data Scheduler was unable to add records to the spool file. Check thepermissions of the file 'spool.dat' and verify the disk space."1686, "The CBS did not process the send request. Possibly, the message sent tothe CBS manager from the scheduler has invalid data. Check the Data Schedulerlog"1690, "The Data Scheduler is closed. Open the data scheduler."1808, "The PLU file cannot be opened. Call customer support."2102, "Unable to communicate with the PLU Reader. Check to see if the PLU reader](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-37.png)

![Configuration Files C-39configuration problem. Use the ESADMIN base config menu option to configureantenna C.2719, "Receive antenna D off error message identifies a problem with receiveantenna D or CBS receive antenna D port. The error may also occur when receiveantenna D is improperly configured using ESADMIN.2720, "Unconfigured receive antenna D error message indicates a hardwareconfiguration problem. Use the ESADMIN base config menu option to configureantenna D.2721, "Signal level threshold error message indicates a CBS Manager thresholdingproblem. Ambient noise in the environment is causing EPL communication problems.Call your NCR Field Engineer immediately.2722, "Noise level threshold error message indicates a CBS Manager thresholdingproblem. Ambient noise in the environment is causing EPL communication problems.Call your NCR Field Engineer immediately.2803, "Log Monitor not configured as interactive error indicates that the LogMonitor service was not configured properly. Click on the "startup" button onthe services dialog box, and enable the "allow service to interact with desktop"option.3000, "Unable to start as service error message indicates that the Windows NTservice could not be started. Use the Windows NT service dialog box to start theservice manually.3005, "Unable to communicate with EPL Table Manager error message indicates thatthe Table Manager was not started properly. Stop and restart the Table Manager.If the problem persists, stop and restart all base software components."3006, "Unable to communicate with PLU Reader error message indicates that the PLUReader was not started properly. Stop and restart the PLU Reader. If theproblem persists, stop and restart all base software components."3007, "Unable to communicate with Data Scheduler error message indicates that theData Scheduler was not started properly. Stop and restart the Data Scheduler.If the problem persists, stop and restart all base software components."3008, "Unable to fork a child process error message indicates that the user isout of resources. Tune system and user parameters.3009, "Unable to open a new virtual terminal error message indicates that thesystem is out of resources. Tune system parameters.6115, "The price is too large to be displayed on the tag."7707, "Unable to open the master IDX [USERIDX.TXT] file. - Defaults will beused."8501, "Invalid or non-existent AMS Configuration file."9003, "Unable to open the PLU file. Check to see if the ACS system is running."EPL Backup Information File (eplbackup.ini)This file identifies which files are backed up when the EPL BackupUtility is run. Wildcard (*) entries are used. Refer to the/appl/epl/data/ directory following installation to determine whichfiles are included in the backup. Additional files may be added.[Backup Files]](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-39.png)

![Configuration Files C-41EPL Status Tag Manager Configuration File (status.cfg)The Status Tag Manager uses this file to display system statusinformation on EPLs. Refer to Appendix D for details about using thisfile with the Status Tag Manager.# EPL Status Tag Manager configuration file## Each entry in this configuration file defines a message to be displayed# on a SmarTalker status tag. A filename may also be defined that can be# used to dynamically change the messages displayed on the status tag.# The format of each entry should look like this:## [SYSTEM]# MODE, I|S|A# FILENAME, "pathname"# EPLID, eplid1 eplid2 ...# DEFAULT_MSG, "MESSAGE"# DEFAULT_UPMSG, "MESSAGE"# DEFAULT_DOWNMSG, "MESSAGE"# IDLETIME, seconds## SYSTEM defines the name of the system for which the status tag is allocated.# There may be multiple entries for each system. SYSTEM should be defined as# "EPL SYSTEM" for all EPL system status tags that use MODE A.# MODE defines one of three modes of operation: (I)mmediate, (S)cheduled, or# (A)utomatic. Immediate mode forces an immediate display of the desired# message. Scheduled mode forces the EPL controller to wait for IDLETIME# seconds before sending the message. Automatic mode updates the status tag# immediately, but displays DEFAULT_DOWNMSG when IDLETIME expires.# FILENAME defines the name of the STAT file that is used to pass new messages# to be displayed on the status tag. FILENAME must be a fully qualified# pathname. (STAT file contents must be ASCII, and only the first 8 characters# are displayed in the status tag's LCD window. The "^" character may be used# to embed descriptor escape sequences.)# EPLID defines the EPLIDs that correspond to the status tags that the user# wishes to allocate to SYSTEM. Multiple EPLIDs may be defined. Each EPLID# must be unique, and must not be allocated in the EPL Table.# DEFAULT_UPMSG defines the message that the status tag displays when the# system's status is good.# DEFAULT_DOWNMSG defines the message that the status tag displays when the# system's status is bad.# DEFAULT_MSG defines a message that is always displayed regardless of the# system's status. The "^" character may be used to embed escape sequences.# IDLETIME is valid for MODES A and S. IDLETIME defines the delay time (in# seconds) beween the time a message is sent to a status tag and the time the# tag's LCD changes.](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-41.png)
![C-42 Configuration Files[EPL SYSTEM]MODE, IEPLID,DEFAULT_MSG, "EPL"[EPL SYSTEM]MODE, IEPLID,DEFAULT_MSG, "SYSTEM"[EPL SYSTEM]MODE, AEPLID,DEFAULT_UPMSG, "HW OK"DEFAULT_DOWNMSG, "HW FAIL"IDLETIME, 300[EPL SYSTEM]MODE, IFILENAME, "/appl/epl/data/STATMOD.001EPLID,DEFAULT_MSG, "SW OK"](https://usermanual.wiki/NCR-RSD-Atlanta/7710GA2.Users-Manual-Appedix-C/User-Guide-47886-Page-42.png)