Menu Screen Searching records You can search for records by their type, point name, code, or by any combination of these values. Searching raw records In the RAW screen, select the Srch softkey to access the raw data search function. • To find a point by name, enter the name in the PT field and press [ENT] twice. You can use the asterisk (*) as a wildcard. For example, when you enter 30* in the PT field, the search matches the points named 300, 301, 302, 3000A2, and 3010. • To find a record by point type, move to the Type field and use [<] or [>] to change the selected point type. The options are ALL, ST, SS, SO, and CO. You can then enter a value in the Code field. – If you select ST or SO in the Type field, you do not have to enter a value in the CD field. Press [ENT] in the PT field to start the search. – If you select CO in the Type field, you cannot enter a value in the PT or CD fields. Press [ENT] in the Type field to start the search. If more than one point matches the specified criteria, the matching points are displayed in a list. Use [^] or [v] to highlight the point that you want to use and then press [ENT] to select it. Detailed data for the selected record appears. Do one of the following: • To change the fields, select the DSP softkey. • To return to the list, press [ENT]. • If no point matches the specified criteria, an error screen appears. Press any button to return to the data screen. Spectra Precision Focus 4 Total Station User Guide 109 5 Menu Screen Searching coordinate records In the XYZ screen, select the Srch softkey to access the XYZ data search function. • To find a coordinate by name, enter the point name in the PT field and press [ENT] twice. You can use the asterisk (*) as a wildcard. For example, when you enter 500* in the PT field, the search matches the points named 500, 500-1, 500-A, and 5000. • To search for a record by point type, move to the Type field and use [<] or [>] to change the selected point type. The options are ALL, SS, SO, MP, UP, and CC. If more than one point matches the search criteria, the matching points are displayed in a list. Use [^] or [v] to highlight the point you want to use and then press [ENT] to select it. If no point matches the specified criteria, an error screen appears. Press any button to return to the data screen. 1 10 Spectra Precision Focus 4 Total Station User Guide Menu Screen Entering coordinates 1. In the XYZ screen, select the Input softkey. A new input point screen appears. The PT field defaults to the last recorded PT + 1, but you can change the value shown. 2. Use the numeric keys to enter the coordinates. Press [ENT] or [v] in each field to move to the next field. When you press [ENT] in the CD field, the point is stored as an MP record. After you have recording a point, the next point input screen is shown with the updated default PT. You can record NE, NEZ, or Z-only data in the database. Spectra Precision Focus 4 Total Station User Guide 111 5 Menu Screen Communication Use the Communication menu to download or upload data. To access it, press [4] or select Comm. on the MENU screen. Downloading coordinate data To change the download settings, press [1] or select Download in the Communication menu. Format NIKON (Fixed) Data RAW Coordinate To display the total number of records that will be downloaded, press [ENT] in the Data field. As each record in the current job is output from the Focus 4 total station, the current line number is updated. Once transferring is completed, you can choose whether to delete the current job: 1 12 • To delete the current job, press [4]. • To return to the Basic Measurement Screen (BMS) without deleting the current job, press [ESC] or select the Abrt softkey. Spectra Precision Focus 4 Total Station User Guide Menu Screen Optional Bluetooth function When the optional Bluetooth wireless technology function is installed, a Port selection screen appears when you press the Comm softkey. Uploading coordinate data To upload coordinate data from a computer, press [2] or select Upload XYZ in the Communication menu. The default data format appears. To change the order of data fields, select the Edit softkey. See also Advanced feature: Editing the data order for upload, page 114. Otherwise, press [ENT]. Select the Job softkey to go to the Job Manager screen. See also Job, page 92. To change the communication settings, select the Comm softkey. The serial port settings must match the settings used by the terminal software on the computer. Use an RS-232C cable to connect the Focus 4 total station to the computer. In the terminal program, set flow control to Xon/Xoff. The Free space field shows the number of points that can still be stored on the Focus 4 total station. Press [ENT] to put the Focus 4 total station in receive mode. On the computer, choose the Send Text File command in the terminal program to start sending data. As each point is received by the instrument, the value in the Records field is incremented. Spectra Precision Focus 4 Total Station User Guide 113 5 Menu Screen If you press [ESC] during data upload, the upload is canceled and the display returns to the Communication menu. Records that were received before you pressed [ESC] are stored in the job. During upload, the system will truncate any code that is longer than 16 characters. If the existing point is a UP, CC, or MP record, and it is not referred to by any station or backsight, it is automatically overwritten by the uploaded point. No error message appears. Advanced feature: Editing the data order for upload 1. Select the Edit softkey. The Data Fields screen appears. 2. To move between the fields, press [<] or [>]. 3. To change the selected item in a field, use the and softkeys. The options are PT, N, E, Z, CD, or blank. 4. To save your changes and return to the previous screen, select the Save softkey. For example, if your original data is as follows: 1, 30.000, 20.000, L1 and you set the data fields to PT N E CD, then the uploaded data is: PT=1, N=30.000, E=20.000, CD=L1 For more information about coordinate data, see Transferring coordinate data to the total station, page 124. Uploading coordinates without points You can upload data without points. If you do not include a point in the format definition, each line of data is automatically assigned the next available point number. To help you to select points in the field, make sure that you store an identifier in the CD field. The data format cannot include duplicate items. Use PT, N, E, Z, and CD once each in the data format. To skip an item in your original file, set the corresponding field to blank. 1 14 Spectra Precision Focus 4 Total Station User Guide Menu Screen 1sec-Key Use the 1sec-Key menu to configure the settings for the one-second buttons, [MSR1], [MSR2], and [DSP]. To access it, press [5] or select 1sec-Keys in the MENU screen. [MSR] button settings There are two [MSR] buttons: • To change the settings for the [MSR1] button, press [1] or select MSR1. • To change the settings for the [MSR2] button, press [2] or select MSR2. Each [MSR] button has four settings. In the Const and Track field, use the numeric keys to enter values. In the other fields, use [<] or [>] to change the settings. Tip – To quickly access the settings screen, hold down [MSR1] or [MSR2] for one second. [DSP] button settings To change the display items in the BMS and in Layout observation screens, press [2] or select [DSP] in the 1sec-Keys menu. To move the cursor, use [<], [>], [^] or [v]. To change the display item, press either the softkey or the softkey. To save the changes, press [ENT] from the last line ofor select the Save softkey. Tip – To quickly access the DSP settings screen, hold down [DSP] for one second. Spectra Precision Focus 4 Total Station User Guide 115 5 Menu Screen Calibration Use the Calibration screen to calibrate the instrument if required. To access the Calibration screen, press [6] or select Calibrat from the MENU screen. See also Adjusting the calibration, page 120. Time Use the Date & Time screen to set the current date and time. 1. Press [7] or select Time on the MENU screen. The Date & Time screen appears. The current date and time settings are displayed. 2. Enter the date in Year-Month-Day format. For example, to change the date to August 15, 2006 press [2] [0] [0] [6] [ENT] [8] [ENT] [1] [5] [ENT]. If the highlighted part of the field ( for example, the year) is already correct, press [ENT] to use the current value. For example, if the date is already set to August 20, 2006, and you want to change the date to August 25, 2006, press [ENT] [ENT] [2] [5] [ENT]. 1 16 3. To move to the Time field, press [ENT] from the Date field: 4. Enter the time in 24-hour format. For example, to set the time to 4:35 PM, press [1] [6] [ENT] [3] [5] [ENT]. 5. Do one of the following: – To finish setting the date and time, press [ENT] in the Minutes field. – To cancel the changes, press [ESC]. Spectra Precision Focus 4 Total Station User Guide CHAPTER Checking and Adjusting In this chapter: Adjusting the electronic level Checking and adjusting the circular level Checking and adjusting the optical/laser plummet Zero point errors of vertical scale and horizontal angle corrections The instrument constant Checking the laser pointer This chapter describes how to check the accuracy of the Focus 4 total station, and if necessary, adjust the required settings. Spectra Precision Focus 4 Total Station User Guide 117 6 Checking and Adjusting Adjusting the electronic level To adjust the electronic level, Zero point errors of vertical scale and horizontal angle corrections are used. See page 119. Checking and adjusting the circular level Once you have checked and adjusted the electronic level, check the circular level. If the bubble is not in the center of the level, use the adjusting pin to rotate the three adjustment screws of either circular level on the instrument main body or tribrach until the bubble is centered. Checking and adjusting the optical/laser plummet The optical axis of the plummet must be aligned with the vertical axis of the instrument. To check and adjust the optical/laser plummet: 1. Place the instrument on the tripod. You do not have to level the instrument. 2. Place a thick sheet of paper marked with an X on the ground below the instrument. 3. Do the following: 4. 1 18 – Look through the optical plummet and then adjust the leveling screws until the image of the X is in the center of the reticle mark . – For the laser plummet, adjust the laser pointer to the X. Rotate the alidade by 180°. – If the marked image is in the same position in the center of the reticle mark, no adjustment is required. – For the laser plummet, if the laser pointer is on the X, no adjustment is required. Spectra Precision Focus 4 Total Station User Guide Checking and Adjusting 5. If the image or laser pointer is not in the same position, adjust the optical or laser plummet: a. Use the supplied hexagonal wrench to turn the adjustment screws until the image of the X is in Position P. Position P is the center point of the line connecting the X and the center of the reticle mark . b. Repeat from Step 2. For laser plummet adjustment, you must remove a cap. Zero point errors of vertical scale and horizontal angle corrections Checking the calibration 1. Set up the instrument on the tripod. 2. Follow the leveling procedures described in Leveling the instrument, page 31. 3. Flip the telescope to the Face-1 position. The display and tangent screws are facing towards you. 4. Sight a target that is within 45° of the horizontal plane. 5. Read the vertical angle from the VA1 field in the Basic Measurement Screen (BMS). 6. Rotate the instrument 180° and flip the telescope to the Face-2 position. The display and tangent screws are turned away from you. 7. Read the vertical angle from the VA2 field. 8. Add the two vertical angles together, VA1 + VA2. – No adjustment is required if the zero reference for vertical angles (VA zero setting) is set to Zenith, and VA1 + VA2 equals 360°. – No adjustment is required if the zero reference for vertical angles (VA zero setting) is set to Horizon, and VA1 + VA2 is either 180° or 540°. – An adjustment is required if VA1 + VA2 is not one of the values listed above. Note – The difference between the vertical angle reading the relevant angle (either 360° for Zenith, or 180° or 540° for Horizon) is called the altitude constant. Spectra Precision Focus 4 Total Station User Guide 119 6 Checking and Adjusting Adjusting the calibration 1. Press [MENU] and [7]. The calibration screen appears. 2. The Focus 4 total station has two-axis level compensation. Take an F1 measurement to a target on the horizon. Press [ENT]. The calibration fields for F1 are: VA1 Face-1 vertical angle (tilt-off value) HA1 Face-1 horizontal angle (tilt-off value) X1 Face-1 X-axis tilt value Y1 Face-1 Y-axis tilt value The vertical angle is shown in the V0 dir= Horiz setting. When you have taken the measurement, the message on the bottom line changes from DO NOT TOUCH! to Turn to F2. 3. Take an F2 measurement to the same target. Press [ENT]. The calibration values for F2 are: VA2 Face-2 vertical angle (tilt-off value) HA2 Face-2 horizontal angle (tilt-off value) X2 Face-2 X-axis tilt value Y2 Face-2 Y-axis tilt value When the observation on F2 is completed, four parameters are displayed. 4. 5. 1 20 Do one of the following: – To return to the first observation screen, press [ESC] or select the Redo softkey. – To set parameters on the instrument, press [ENT] or select the OK softkey. If ACV, ACH, or Tilt is out of range, OVER appears. Press any key to return to the first observation screen. Spectra Precision Focus 4 Total Station User Guide Checking and Adjusting The instrument constant The instrument constant is a numerical value used to automatically correct for the displacement between the mechanical and electrical centers when measuring distances. The instrument constant is set at the factory. However, to ensure the highest operational accuracy, we recommend that you check the instrument constant several times a year. The following figure shows the setup to check the instrument constant. About 100 m To check the instrument constant: 1. Set up the instrument at Point P, in as flat an area as possible. 2. Set up a reflector prism at Point Q, 100 m away from Point P. Make sure that you take the prism constant into account. 3. Measure the distance between Point P and Point Q (PQ). 4. Install a reflector prism on the tripod at Point P. 5. Set up another tripod at Point R, on the line between Point P and Point Q. 6. Transfer the Focus 4 total station to the tripod at Point R. 7. Measure the distance from Point R to Point P (RP), and the distance from Point R to Point Q (RQ). 8. Calculate the difference between the value of PQ and the value of RP + RQ. 9. Move the Focus 4 total station to other points on the line between Point P and Point Q. 10. Repeat Step 5 through Step 9 several times (about ten times). 11. Calculate the average of all the differences. The error range is within 3 mm. If the error is out of range, contact your dealer. Spectra Precision Focus 4 Total Station User Guide 121 6 Checking and Adjusting Checking the laser pointer The Focus 4 total station uses a red laser beam to a laser pointer. The laser pointer is coaxial with the line of sight of the telescope. If the instrument is well adjusted, the red laser pointer coincides with the line of sight. External influences such as shock or large temperature fluctuations can displace the red laser pointer relative to the line of sight. 1 22 Spectra Precision Focus 4 Total Station User Guide CHAPTER Transferring Coordinate Data Transferring coordinate data to the total station Transferring coordinate data from the total station The Focus 4 uses lists of coordinate data. This chapter describes how to transfer data between the Focus 4 total station and the office computer. Spectra Precision Focus 4 Total Station User Guide 123 7 Transferring Coordinate Data Transferring coordinate data to the total station Settings To configure the transmission speed and other settings, press [MENU] and then select Settings / Comm. See also Communications, page 99. Record format You can transfer coordinate records to the Focus 4 total station in the following formats: PT PT PT PT 1 24 PT PT CD PT PT PT PT CD CD CD Spectra Precision Focus 4 Total Station User Guide CD Transferring Coordinate Data The formats use the following codes: Code Description Length PT Point number Up to 20 digits Actual X coordinate Variable length Actual Y coordinate Variable length Actual Z coordinate Variable length CD Feature code Up to 16 characters Data example 20100,6606.165,1639.383,30.762,RKBSS 20104,1165611.6800,116401.4200,00032.8080 20105 5967.677 1102.343 34.353 MANHOLE 20106 4567.889 2340.665 33.444 PT1 20107 5967.677 1102.343 34.353 20109,4657.778,2335.667,,PT2 20111,4657.778,2335.667 20113 4657.778 2335.667 20115,,,34.353,MANHOLE 20117,,,33.444 Transferring coordinate data from the total station Settings To configure the transmission speed and other settings, press [MENU] and then select Settings / Comm. See also Communications, page 99. Data examples Nikon coordinate data format 1,100.0000,200.0000,10.0000, 2,200.0000,300.0000,20.0000, 3,116.9239,216.9140,11.8425,TRAIN PLATFORM 4,126.6967,206.2596,11.2539,RAMP 11,100.0045,199.9958,10,0000, 13,116.9203,216.9113,11.7157, 14,126.6955,206.2579,10.9908, 21,100.0103,199.9958,10.0000, 31,100.0013,200.0005,10.0000, 41,100.0224,200.0331,9.9000, 43,116.9263,216,9165,11.8016,CURB 44,126.7042,206.2871,10.8193,DITCH 45,116.9266,216.9160,11.8028, 46,126.7046,206.2845,10.8213,CP POINT Spectra Precision Focus 4 Total Station User Guide 125 7 1 26 Transferring Coordinate Data Spectra Precision Focus 4 Total Station User Guide APPENDIX Specifications In this chapter: Main body Standard components External device connector This appendix details the specifications and standard components of the Focus 4 total station. It also describes the connector that is used to connect the instrument to an external power source or to communicate with an external device. Spectra Precision Focus 4 Total Station User Guide 127 A Specifications Main body Telescope Tube length 125 mm (4.91 inch) Magnification 30× Effective diameter of objective 45 mm (1.77 inch) EDM 50 mm (1.97 inch) Image Erect Field of view 1°20' 2.3 m at 100 m (2.3 ft at 100 ft) Resolving power 3.0" Focusing distance 1.5 m to infinity (59 inch to infinity) Measurement range Distances shorter than 1.5 m (4.92 ft) cannot be measured with this EDM. Measurement range with no haze, visibility over 40 km (25 miles) Prism mode Reflector sheet (5 cm x 5 cm) 300 m (984 ft) Standard prism (1P) 5,000 m (16,400 ft) Reflectorless mode Reference target 300 m (984 ft) Notes – The target should not receive direct sunlight. “Reference target” refers to a white, highly reflective material (KGC 90%). In reflectorless mode, the maximum measurement range is 500 m (1,640 feet). 1 28 Spectra Precision Focus 4 Total Station User Guide Specifications Distance measurement precision Precise mode Prism mode ± (3 + 2 ppm × D) mm –10 °C through +40 °C (+14 °F through +104 °F) ± (3 + 3 ppm × D) mm –20 °C through –10 °C, +40 °C through +50 °C (–4 °F through +14 °F, +104 °F through +122 °F) Reflectorless mode ± (3 + 2 ppm × D) mm –10 °C through +40 °C (+14 °F through +104 °F) ± (3 + 3 ppm × D) mm –20 °C to –10 °C, +40 °C through +50 °C (–4 °F through +14 °F), (+104 °F through +122 °F) Normal mode Prism mode ± (10 + 5 ppm × D) mm Reflectorless mode ± (10 + 5 ppm × D) mm Measurement intervals Measurement intervals may vary with the measuring distance or weather conditions; At the initial measurement, it may take a few more seconds. Precise mode Prism mode 1.5 sec. Reflectorless mode 1.8 sec. Normal mode Prism mode 0.8 sec. Reflectorless mode 1.0 sec. Prism offset correction –999 mm to +999 mm (1 mm step) Angle measurement Reading system Absolute encoder Diameterial reading on HA Single reading on VA Minimum display increment 360° 1"/5"/10" 400G 0.2 mgon / 1 mgon / 2 mgon MIL6400 0.005 mil / 0.02 mil / 0.05 mil DIN18723 accuracy 5"/ 1.5 mgon Spectra Precision Focus 4 Total Station User Guide 129 A Specifications Tilt sensor Method Liquid-electric detection (dual axis) Compensation range ±3’ Tangent screws Type Friction clutch endless fine motion Tribrach Type Detachable Electronic level Displayed on the LCD Circular level vial Sensitivity 10' / 2 mm Level Optical plummet Image Erect Magnification 3x Field of view 5° Focussing range 0.5 m (1.6 ft) to infinity Wave length 635 nm Laser class Class 2 Focusing range Optical laser plummet (option) Laser diameter Approximately 2 mm Display and keypad 1 30 Display type Graphical LCD Resolution 128 × 64 Display illumination Backlight Keys 25 Spectra Precision Focus 4 Total Station User Guide Specifications Connections in the base of instrument Communications Type RS-232C Maximum baud rate 38400 bps asynchronous External power supply input voltage 4.5 V through 5.2 V DC Battery pack Output voltage 3.8 V DC rechargeable Continuous operation time Continuous distance/angle measurement 10 hours Distance/angle measurement every 16 hours 30 seconds Continuous angle measurement 30 hours Note – Tested at 25 °C (77 °F) (normal temperature). Operation times may vary depending on the condition and deterioration of the battery. Environmental performance Operating temperature range –20 °C through +50 °C (–4 °F through +122 °F) Storage temperature range –25 °C through +60 °C (–13 °F through +140 °F) Dimensions Main unit 149 mm W x 145 mm D x 306 mm H (5.87 inch W x 5.7 inch D x 12.0 inch H) Carry case 435 mm W x 206 mm D x 297 mm (17.1 inch W x 8.1 inch D x 11.7 inch H) Weight Main unit (without battery) Approximately 3.5 kg (7.7 lbs) Battery Approximately 0.1 kg (0.22 lbs) Carry case Approximately 2.4 kg (5.3 lbs) Charger and AC adaptor Approximately 0.4 kg (0.88 lbs) Spectra Precision Focus 4 Total Station User Guide 131 A Specifications Environmental protection Watertight/dust-proof protection IP66 Standard components • Instrument main body • Battery pack (x 2) • Universal Charger, power cord, and adaptors • Adjustment pin, Allen wrench • Vinyl cover • The Spectra Precision Focus 4 Total Station User Guide (this document) • Carry case External device connector This connector can be used to connect to an external power source or to communicate with an external device. Before using the external device connector, make sure that the external device meets the specifications below. 1 32 Input voltage 4.5 V DC to 5.2 V DC System RS-232C Signal level ±9 V standard Maximum baud rate 38400 bps asynchronous Compatible male connector Hirose HR10A-7P-6P or HR10-7P-6P CAUTION – Except when connected as shown in the System diagram, page 18, use of the Hirose HR10A-7P-6P or HR10-7P-6P is at your own risk. CAUTION – Use only the male connectors specified above. Using other connectors will damage the instrument. Spectra Precision Focus 4 Total Station User Guide Specifications The external device connector is a Hirose HR 10A-7R-6S female connector. The pinouts for connecting the Focus 4 to an external device connector are shown below: Pin Signal Description RxD Receive data (Input) TxD Send data (Output) NC No connection Power GND Ground NC No connection HRS CAUTION – Only use the pin connections shown above. Using other connections will damage the instrument. CAUTION – The Focus 4 total station has different pin assignments from other Spectra Precision total stations. To connect to an external power source, supply power to Pin 4 (power terminal) and Pin 5 (ground terminal) on the instrument. The instrument will use the external power source even if the internal battery packs is attached. CAUTION – Make sure that the power supplied is within the rated input range (4.5 V to 5.2 V, 1 A maximum). Power supplied outside this range will damage the instrument. To communicate with an external device, connect the RS-232C signal from the external device to Pin 1 (input terminal) and to Pin 2 (output terminal) on the Focus 4. Cap the data output/external power input connector securely when the Focus 4 is not in use. The instrument is not watertight if the cap is detached or not attached securely, or when the data output/external power input connector is in use. The Focus 4 can be damaged by static electricity from the human body discharged through the data output/external power input connector. Before handling the instrument, touch any other conductive material once to remove static electricity. Spectra Precision Focus 4 Total Station User Guide 133 A 1 34 Specifications Spectra Precision Focus 4 Total Station User Guide APPENDIX Error Messages In this chapter: Cogo Communications Data Job manager Stakeout Programs Recording data Searching Settings Station setup System error The appendix describes the error messages that may appear when you use the Focus 4 total station. Spectra Precision Focus 4 Total Station User Guide 135 B Error Messages Cogo NO Result The system was unable to calculate an area because points were not entered in the correct order. Press any key to return to the Cogo menu. Then enter the points in the correct order. Same Coordinate The point or coordinate that you entered is identical to the previous input point. Press any key to return to the point input screen. Then use a different point. XY-coordinate is required The input point does not have XY (NE) coordinates. Press any key to return to the point input screen. Then enter a point that has X and Y coordinates. Communications If an error is detected while data is being transferred to the Focus 4 total station, the Focus 4 total station stops the transfer and displays one of the following messages: Check Data There are errors in the data that is being transferred to the Focus 4 total station, such as an alphabetic character in a coordinate field. Press any key. Then check the specified line in the data. DUPLICATE PT CAUTION – If the existing point is a UP, CC, or MP record, and the point is not referred to by ST or BS, the existing point will be overwritten by the uploaded record. No error message appears. The uploaded data contains a duplicate PT. Press any button. Then check the specified point in the data. PT MAX20 chars The uploaded data contains a PT with a name or number that is longer than 20 digits. Press any button. Then check the specified line in the data. XYZ OVERRANGE The uploaded data contains a coordinate that is longer than 13 digits. Press any button. Then check the specified line in the data. 1 36 Spectra Precision Focus 4 Total Station User Guide Error Messages Data Can't Edit Current ST You have tried to edit the current ST. You cannot edit the current ST. Note – Old ST records can be edited, but no recalculation can be performed on the instrument. Press any key to return to the code/layer name input screen. Can't Edit ST/BS refer to this PT You have tried to edit a coordinate that the current ST or BS refers to. You cannot change a coordinate if the current ST or BS refers to it. Press any key to return to the Data view screen. Can't Edit XYZ from measurement You have tried to change the coordinates of an SO, SS, or CP record. You cannot change the coordinates of these records. Press any button to return to the previous screen. DELETE Stn-XYZ You have tried to delete a coordinate record that the current ST or BS refers to. You must confirm that you want to delete this record. To... Press... delete XYZ the DEL softkey return to the previous screen without deleting XYZ [ESC] or the Abrt softkey Job manager Cannot Assign You have tried to set the current job as the control file. Press any button to return to the previous screen. Then select a different job. Can't Create There is no space available to create a job or record a point. Press any button to return to the Job Manager. Then select the DEL softkey to delete old jobs. Existing Job You have entered an existing job name for a new job. Press any button and then change the name for the new job. Spectra Precision Focus 4 Total Station User Guide 137 B Error Messages MAX 32Jobs You are trying to create a new job when the maximum number of jobs (32) is already stored. Press any button to return to the Job Manager. Then select the DEL softkey to delete old jobs. Stakeout Input Error The point name style used in the Fr field is not the same as the style used in the To field. For example, the Fr field style is 1, and the To field style is A200. Press any button to return to the Fr/To input screen. Then re-enter the point name, using the same naming style in both fields. NO Stn Setup You did not perform a station setup or BS check before entering the Stakeout function. 1 38 To... Press... go to the Stn Setup menu [2] or select Stn Setup return to the Basic Measurement Screen (BMS) [ESC] go to the Stakeout menu [1] or select Continue CAUTION – Selecting Continue does not resume the last ST record. You should only use the Continue option if you are sure that the previous ST coordinates and the current HA orientation are correct. Otherwise, records in the Stakeout function may not be correct. Spectra Precision Focus 4 Total Station User Guide Error Messages Programs NO Stn Setup CAUTION – Selecting Continue does not resume the last ST record. You should only use the Continue option if you are sure that the previous ST coordinates and the current HA orientation are correct. Otherwise, records in the Programs function may not be correct. You did not perform a station setup or BS check before entering the Programs function. To... Press... go to the Stn Setup menu [2] or select Stn Setup return to the BMS [ESC] go to the Programs menu [1] or select Continue Recording data DATA FULL The data storage is full. Press any button to return to the Basic Measurement Screen (BMS). Then: To... Press... delete unnecessary data [MENU] and select Data delete jobs [MENU] and select Job DUPLICATE PT The input PT you are trying to record already exists in the current job. An existing coordinate record cannot be overwritten by measured data. Press any button to return to the point input screen. Change the setting in the PT field. Duplicate PT The input PT you are trying to record already exists in the current job as an SS, SO, or CP record. An existing SS, SO, or CP record can be overwritten by measured data. To... Press... return to the PT input screen [ESC] or the Abrt softkey record RAW data and update XYZ data the XYZ softkey record RAW data only the RAW softkey Spectra Precision Focus 4 Total Station User Guide 139 B Error Messages No Open Job No job is open. To... Press... open the job list, if there are existing jobs [1] or select Select job create a new job [2] or select Create job return to the previous screen [ESC] NO Stn Setup There is no station record in the current job, or a station setup or BS check has not been done since the program was rebooted. To... Press... continue recording [1] or select Continue. If there is already an ST record in the job, the message CO, Use current orientation appears. go to the Stn Setup menu [2] or select STN Setup return to the previous screen [ESC] OVER RANGE You are trying to record a coordinate with more than 13 digits. Press any button to return to the previous screen. Then check the setting for the current ST coordinate. Searching PT Not Found There is no point that matches the criteria entered. Press any button to return to the point input screen. This message may appear in any function where the PT/CD is input, such as Station Setup or Stakeout. 1 40 Spectra Precision Focus 4 Total Station User Guide Error Messages Settings Job Settings will be changed You have changed one or more of the following job settings: • VA zero or HA in the Angle screen (see Angle, page 96) • Scale, T-P, Sea Lvl, or C&R in the Distance screen (see Distance, page 96) • Coord or Az Zero in the Coordinates screen (see Coordinate, page 99) • Angle, Dist, Temp, or Press in the Unit screen (see Unit, page 99) To... Press... discard the changes to the job settings [ESC] or the Abrt softkey. The current job remains close the current job and save the changes to the job settings [ENT] or the OK softkey. open. Note – To record a point using the new settings, create a new job using the new settings. Station setup Same Coordinate The input PT or coordinate is identical to the current station in STN/2:Known, or the same coordinate or point name/number is found in Resection. Press any button to return to the PT input screen. Then use a different PT. Space LOW There is not enough space to record a station when you start any of the Station Setup functions. To... Press... return to the BMS press [ESC] or select the Abrt softkey. Select the DEL softkey in Job Manager to delete old jobs. continue press [ENT] or select the OK softkey. You may not be able to record the whole process. XY-coordinate is required The input point for ST/BS does not have N/E coordinates. Press any button to return to the PT input screen. Then use a PT that has N/E coordinates. Spectra Precision Focus 4 Total Station User Guide 141 B Error Messages Z-coordinate is required The input point for Benchmark does not have a Z coordinate. Press any button to return to the PT input screen. Then use a PT that has a Z coordinate. See page 68. System error =SYSTEM ERROR= The system has detected an internal error that is related to the lower-level system. Press any key to turn the instrument off. The system will reboot when this error is reported. If you still have more points to shoot in the site, turn the instrument on and repeat the open a job and station setup procedures. Data stored before this error will be kept safely in the Job file. If the error appears frequently, please contact your dealer or Trimble Support and report the message that appears below the =SYSTEM ERROR= line. 1 42 Spectra Precision Focus 4 Total Station User Guide Spectra Precision 10355 Westmoor Drive, Suite #100 Westminster, CO 80021 USA +1-720-587-4700 Phone 888-477-7516 (Toll Free in USA) www.spectraprecision.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Modify Date : 2009:03:13 09:00:04+13:00 Create Date : 2009:03:13 09:00:04+13:00 Metadata Date : 2009:03:13 09:00:04+13:00 Creator Tool : FrameMaker 8.0 Format : application/pdf Title : Spectra Precision Focus 4 Total Station User Guide Creator : Trimble Technical Publications Document ID : uuid:8c1313ac-8bba-4395-a777-ca91860c6e60 Instance ID : uuid:c3c51914-ee55-4344-8d42-feb2b554a771 Producer : Acrobat Distiller 9.0.0 (Windows) Page Count : 36 Author : Trimble Technical PublicationsEXIF Metadata provided by EXIF.tools