NIKON TRIMBLE NT0001 Bluetooth module User Manual Nivo manual 3
NIKON-TRIMBLE CO., LTD. Bluetooth module Nivo manual 3
Contents
Host 2 user manual 3 of 3
CHAPTER Menu Key In this chapter: Introduction Job Manager Cogo Settings Data Communication 1sec-Keys Calibration Time Total Station Nivo Series Instruction Manual 91 5 Menu Key Introduction Use the MENU screen to access important functions and settings. To display the MENU screen, press the [MENU] key. Job Manager Use the job manager to open, create, delete, and manage jobs. To open the Job Manager, press [1] or select Job on the MENU screen. If there are jobs stored on the instrument, the job list appears, showing all the stored jobs. The newest job appears at the top of the list. If there are no jobs stored, the Create Job screen appears. See Creating a new job, page 93. Opening an existing job The job list shows all the jobs stored on the instrument, in descending date order. The following symbols may be used to provide extra information about jobs: Symbol Meaning Current job. Control job. Some of the job settings are different from the current job. Job was created in an older DB. Older files cannot be opened in version 1.10 or later of the software. Press [^] or [v] to move up or down the job list. Press [ENT] to open the highlighted job. When you open a job, all job settings are automatically changed to match those used in the open job. 92 Total Station Nivo Series Instruction Manual Menu Key Creating a new job 1. 2. Press the Creat softkey in the job list. Enter a job name of up to eight characters. Press [ENT]. 3. Do one of the following: – To check the job settings, press the Sett softkey. – To create a new job using the current job settings, press [ENT] or the OK softkey. Job settings The following settings are set when a job is created, and cannot be changed. This ensures that the data in a job is correctly stored in the database, and that all necessary corrections are applied when you store each record. Scale Factor T-P correction Sea Level C&R correction 0.999600 to 1.000400 ON/OFF ON/OFF OFF/0.132/0.200 Angle unit DEG/GON/MIL Distance unit Temp unit Press unit Metre/US-Ft/I-Ft °C/°F hPa/mmHg/inHg If you select US-Ft or I-Ft, an additional settings screen appears. Use this screen to specify whether to display values in Decimal-Ft or Ft-Inch. VA zero AZ zero Order HA Zenith/Horizon/Compass North/South NEZ/ENZ Azimuth/0 to BS Total Station Nivo Series Instruction Manual 93 5 Menu Key To move between fields, press [^] or [v]. Alternatively, to move to the next field, press [ENT]. To change the setting in the selected field, press [<] or [>]. To confirm the job settings and create the job, press [ENT] in the last field (HA). These settings are separate from other temporary settings. Deleting a job Tip – There is no undelete function in the Job Manager. Before you press [ENT] or select DEL, make sure that the selected job is the one that you want to delete. 1. In the job list, highlight the job that you want to delete. 2. Press the DEL softkey. A confirmation screen appears. 3. Do one of the following: – To delete the selected job, press [ENT] or the DEL softkey. – To cancel the deletion and return to the previous screen, press [ESC] or the Abrt softkey. After you delete a job, the display returns to the job list. Setting the control job If you search for a point when a control job is specified, and the system cannot find the point in the current job, the control job is also searched. If the point is found in the control job, it is copied to the current job as a UP record. A control job has the same format as a standard job. You can open and modify it like any other job, and you can use it to record any measured data. To set the control job: 94 1. Highlight the job that you want to use. 2. Press the Ctrl softkey. Total Station Nivo Series Instruction Manual Menu Key A confirmation screen appears. 3. Do one of the following: – To set the selected job as the control job, press [ENT] or the Yes softkey. – To cancel the process, press [ESC] or the No softkey. If a control job is already assigned, the newly assigned control job replaces it as the control job. To clear the control job selected, highlight the current control job in the job list and press the Ctrl softkey. Then press [ENT] or the Yes softkey to confirm. Displaying job Information To display job information, highlight the job name and then press the Info softkey. The Information screen shows the number of records in the job, the free space, and the date when the job was created. Free space indicates how many points can be stored in the job. To return to the job list, press any key. Total Station Nivo Series Instruction Manual 95 5 Menu Key Cogo Use the Cogo menu to perform coordinate geometry (COGO) calculations. You can access this menu at any time from any observation or PT input screen. To open the Cogo menu, press [2] or select Cogo on the MENU screen. Calculating angle and distance between two coordinates To open the Inverse menu, press [1] or select Inverse in the Cogo menu. PT-PT inverse PT-PT calculates the distance and the angle between two input points. To calculate a PT-PT inverse: 1. Press [1] or select PT-PT in the Inverse menu. 2. Enter the first point number or name. Press [ENT]. If you press [ENT] without entering a point name, a coordinate input screen appears, and you can enter coordinates. These coordinates are not stored to the database. If you want to store the point, specify a new point name. 3. Type the second point number/name and press softkey allows you to shoot the point on the spot to use it in the calculation. [ENT]. The MSR The azimuth, horizontal distance, and vertical distance from the first point to the second point are displayed. 96 Total Station Nivo Series Instruction Manual Menu Key 4. Gd V% rSD Do one of the following: – To return to the PT input screen, press [ESC]. – To return to the COGO menu, press [ENT]. – To change the contents of the result screen, press [DSP]. Grade (HD/VD) 100/Gd Slope distance PT1 to PT2 3Pt angle The 3Pt Angle function calculates the angle between two lines defined by three points. To calculate a 3Pt angle: 1. Press [2] or select 3Pt Angle in the Inverse menu. P1 is the base point. Two lines are to be defined by P2 and P3, both from P1. 2. Enter the point name, or use the MSR softkey to take a measurement to the point. 3. Enter the second point (P2) to define the baseline (P1-P2). The angle (dHA) is measured from the baseline. 4. Enter the third point (P3) to define the second line (P1-P3). When you press the MSR softkey, a temporary measuring screen appears. Sight the target and press [MSR1] or [MSR2] to take a measurement. After the measurement, a recording point screen appears. To store the measured point, enter the PT, HT, and CD values and press [ENT]. To use the point without recording it, press [ESC]. Total Station Nivo Series Instruction Manual 97 5 Menu Key When you have entered three points, the instrument calculates the angle and distances. 5. Do one of the following: – To return to the Inverse menu, press [ENT]. – To return to the Input BasePt screen, press [ESC]. Calculating and manually inputting coordinates To enter the Input menu, press [2] or select Input in the Cogo menu. There are three functions in this menu for recording new coordinate points. Azimuth+HD input To calculate a coordinate by an angle and distance input from the base point (P1), press [1] or select AZ+HD in the Input menu. Enter the base point (P1). Type the point name and press [ENT]. Enter the azimuth, horizontal distance, and vertical distance. Then press [ENT]. To enter 123°45'45", type 123.4545 and press [ENT]. If you do not enter a value in the dVD field, the value 0.000 is used. A recording point screen with the calculated coordinates appears. PT defaults to the last recorded PT + 1. Press [ENT] to store the point. 98 Total Station Nivo Series Instruction Manual Menu Key Traverse To open the Traverse (2Pt Angle) function, press [2] or select Traverse in the Input menu. Traverse function calculates a new point based on the two defined points and angle, horizontal and vertical distances from the line defined by those two points. To enter P1 and P2, enter point names or take measurements to targets. Enter the plus-minus angle, horizontal distance, and vertical distance from the baseline defined by P1-P2. If you do not enter a value in the dVD field, the value 0.000 is used. When you press [ENT] in the dVD field, a new point is calculated. The PT name defaults to the last recorded PT + 1. To record the new point and return to the point input screen, press [ENT]. P1 (base PT) defaults to the previously recorded PT. P2 defaults to the previous P1. To continuously calculate a new point, enter +Ang, HD, and dVD from the previous bearing line. This is a convenient way to enter Traverse points. Entering coordinates To manually enter the XYZ coordinates, press [3] or select Input XYZ in the Input menu. The PT name defaults to the last recorded PT + 1. Enter the coordinates using the numeric keys. To move to the next field, press [ENT] or [v] in a field Total Station Nivo Series Instruction Manual 99 5 Menu Key To store the point as an MP record and return to the point input screen, press [ENT] in the Z field. The default PT is incremented to the next value. You can record NE, NEZ, or Z-only data to the database. Calculating area and perimeter To calculate an area or perimeter, press [3] or select Area & Perim in the Cogo menu. To take a measurement, enter the first point and press [ENT], or press the MSR softkey. In the upper right corner of the screen, a counter indicates how many points you have entered. To input point numbers consecutively, use the Fr/To softkey. For more information, see Advanced feature: Entering a range of points, page 101. If you enter a new point name, you can enter new coordinates and record the point. If you do not want to record the point, press [ENT] without entering a value in the PT field. An XY coordinate input screen appears. Continue to enter points until you have defined all the points in the lot. Then, press [v] to calculate the area and perimeter. The first and last points that you enter are joined to close the area. You must enter the points in the order in which they define the lot. You can enter up to 99 points. Press [ENT] to store the calculated values as a a comment record, or press [ESC] to return to the Cogo menu. 100 Total Station Nivo Series Instruction Manual Menu Key If you chose to store the area, enter a name to identify the area and then press [ENT]. When you download data in Nikon RAW format, area (AR) records are output as comment (CO) records. Advanced feature: Entering a range of points To quickly enter a sequential range of points, use the range input function. To access this function, press the Fr/To softkey in the No. 01 or No. 02 input screens. Enter the start point name in the Fr field and the end point name in the To field. You can include letters and hyphens in the point names, but the last character must be numeric. Press [ENT] in To field to start searching for matching points. The counter shows the number of matching points found. When the search is complete, you are returned to the Input PT screen. Press the Calc softkey to calculate the area and perimeter, or enter point names in the PT field. Press [ESC] to return to the Input PT screen with the preceding point name. Total Station Nivo Series Instruction Manual 101 5 Menu Key Calculating coordinates from line and offset To enter the Line & offset function, press [4] or select Line & O/S in the Cogo menu. Enter the base point (P1). Specify the azimuth bearing. To do this, enter a value in the AZ or P2 field. P2 is a second point on the line. Enter the horizontal distance along the baseline (Sta), the horizontal distance perpendicular to the line (O/S), and the vertical distance (dVD). A negative value in the Sta field means the opposite direction along the defined bearing line. A negative value in the O/S field is for the left-hand side of the bearing line. To calculate the coordinates of the point (PM), press [ENT] in the dVD field. You can change the Z coordinate here. To record the point, press [ENT] in the CD field. 102 Total Station Nivo Series Instruction Manual Menu Key The coordinates are stored as a CC record. Line definition information and Sta, O/S, and dVD values are stored in comment (CO) records. Calculating coordinates using intersection functions To enter the Intersection menu, press [3] or select Intersection in the Cogo menu. There are four functions in this menu for calculating coordinates. Calculating a bearing-bearing intersection A bearing-bearing intersection is the intersection point of two lines. 1. To calculate a bearing-bearing intersection, press [1] or select Brng-Brng in the Intersection menu. 2. Enter the first point name and press [ENT]. Alternatively, to measure directly to the point, press the MSR softkey. 3. Define the first line by azimuth. 4. To define the line by two points, press the Pts softkey. The Fr field defaults to the P1 point, but you can change the selected point. In the To field, enter or measure to the second point. For more information about the O/S softkey, see Advanced feature: Entering angle and distance offsets, page 107. 5. Do one of the following: – To return to the previous screen, press [ESC]. The calculated value appears in the AZ field. – To go to the next screen, press [ENT]. Total Station Nivo Series Instruction Manual 103 5 Menu Key 6. Define the second line by two points or by P2 and AZ. 7. To calculate the coordinates of the intersection point, press [ENT] in the AZ field. The calculated coordinates are displayed. You can input a Z coordinate if necessary. 8. Enter a value in the PT field and in the CD field. 9. To record the point, press [ENT]. Sample records CO,Int BB P1:P10 AZ:330.54175-90.00000 CO, P2:408 AZ:100.0000+0.0000 CC,A123,,4567.3080,200.1467,-1.2056,POT Calculating a bearing-distance intersection 1. Press [2] or select Brng-Dist in the Intersection menu. Brng-Dist calculates the intersection point formed by one line and one distance (radius). 2. Enter a point on the line. The line can be defined by two points or by a point and an azimuth. 3. 104 Enter the second point (P2) as the center of the circle. Total Station Nivo Series Instruction Manual Menu Key 4. Enter the distance from P2. – To define the distance (HD) by two points, press the Pts softkey. – To calculate the coordinates of the intersection point, press [ENT] in the HD field. 5. If there are two results, the first solution appears graphically relative to the P1-P2 line. To display the second solution, press [<] or [>]. 6. To record the point, press [ENT] when the required solution appears. 7. Enter a Z coordinate if necessary. 8. To move to the PT and CD fields, press [ENT]. Sample records CO,Int BD P1:4672 AZ:330.54175+0.00000 CO, P2:71 HD:100.0000 CC,504,,-839.3065,347.6682,,SIGN Calculating a distance-distance intersection 1. Press [3] or select Dist-Dist in the Intersection menu. 2. Enter the first point name and press [ENT], or press the MSR softkey to measure directly to the point. 3. Enter the distance from P1 and press [ENT]. 4. To define the distance (HD) by two points, press the Pts softkey. 5. Enter P2 and the distance from P2 (HD). 6. To calculate the coordinates of the intersection point, press [ENT] in the HD field. Total Station Nivo Series Instruction Manual 105 5 Menu Key 7. Press [<] or [>] to display the second solution. 8. To record the point, press [ENT] when the required solution appears. 9. Enter a Z coordinate if necessary. Press [ENT] to move to the PT and CD fields. Sample records CO,Int DD P1:486 HD:330.6020 CO, P2:7 HD:100.0000 CC,505,,236.5817,50.0461,0.0000, Calculating a point-line intersection 1. Press [4] or select Pt-Line in the Intersection menu. 2. Enter the first point name and press [ENT], or press the MSR softkey to measure directly to the point. 3. Enter the azimuth, or press the Pts softkey to enter another point name on the line. 4. Enter the perpendicular point to the line, or press the MSR softkey to take a measurement to the point. 5. To calculate the coordinates of the intersection point, press [ENT]. If P1 and P2 are 3D points, the Z coordinate of the perpendicular point is calculated relative to the P1-P2 slope. 6. Enter PT and CD then press [ENT] to record the point. Sample records CO,Int PtLine P1:38 AZ:90.00000+0.00000 CO, P2:506 CC,A-123,,4567.3080,200.1467,-1.2056,POT 106 Total Station Nivo Series Instruction Manual Menu Key Advanced feature: Entering angle and distance offsets To display the offset input screen, press the O/S softkey. In the Ang field, enter a positive value to rotate the line clockwise. Enter a negative value to rotate the line counterclockwise. In the O/S field, enter a positive value to specify an offset to the right. Enter a negative value to specify an offset to the left. Total Station Nivo Series Instruction Manual 107 5 Menu Key Settings To display the Settings menu, press [2] or select Settings on the MENU screen. Use this menu to configure the initial job settings. Some job settings, specified in the following sections, cannot be changed once a job is created. If any of these settings are changed while a job is open, a confirmation screen appears, asking you to create a new job with the new settings, or to work with those settings without recording any data. For more information, see Settings, page 174. Angle To open the Angle menu, press [1] or select Angle in the Settings menu. VA zero Zenith/Horizon/Compass The VA zero job setting cannot be changed once a job is created. Resolution HA 1"/5"/10" or 0.2 mgon/1 mgon/2 mgon 0 to BS/Azimuth The HA job setting cannot be changed once a job is created. When this field is set to Azimuth, the horizontal angle (HA) that appears and recorded is in Azimuth value. When this field is set to 0 to BS, HA is in HA zero to BS value. 108 Total Station Nivo Series Instruction Manual Menu Key Distance To open the Distance menu, press [2] or select Distance in the Settings menu Scale T-P corr. Sea Level C&R corr. Numeric value between 0.999600 and 1.000400 ON/OFF ON/OFF OFF/0.132/0.200 The Scale, T-P corr., Sea Level, and C&R corr. job settings cannot be changed once a job is created. Temperature and Pressure corrections 10000.0 106 × P × § ---------------------------------------------· © 13.5951 × 980.665¹ K = 275 – --------------------------------------------------------------------------273 + T SD' = § 1 + ---------------------· × SD © 1000000¹ SD SD' Slope dist. (before adj.) Slope dist. (after adj.) Compensation coefficient Pressure (hPa) Temperature (°C) Sea Level correction HD × R e HD' = -----------------------R e + Z STN HD HD' Horizontal dist. (before adj.) Horizontal dist. (after adj.) ZSTN Re Instrument-Z 6370 km Curvature and Refraction correction Because the surface of the earth is curved, the vertical difference (VD and Z) at the measurement point, as referenced to the horizontal plane, inevitably includes some error. This error is called curvature error. Also, because the density of the air Total Station Nivo Series Instruction Manual 109 5 Menu Key surrounding the earth decreases with altitude, light is refracted at different rates at different altitudes. The error caused by this change in refraction is called refraction error. Curvature error (A A') Refraction error (A A1') A' Horizontal A1' direction A1 A' HD HD’ VD VD' SD Horizontal dist. (before adj.) Horizontal dist. (after adj.) Vertical dist. (before adj.) Vertical dist. (after adj.) Slope distance VA Re Vertical angle 6370 km C&R constant (0.132 or 0.200) SD sin ( 2VA ) HD' = HD – ----------------------------------- § 1 – ---· © 2R e 2¹ HD VD' = VD + ----------- ( 1 – k ) 2R e Coordinate To open the Coordinate menu, press [3] or select Coord. in the Settings menu. Order Label AZ NEZ/ENZ XYZ/YXZ/NEZ(ENZ) North/South The Order and AZ job settings cannot be changed once a job is created. Power saving To open the Power Save menu, press [4] or select PwrSave in the Settings menu. Main Unit EDM Unit Sleep 110 OFF/5min/10min/30min OFF/At once/0.1min/0.5min/3min/10min OFF/1min/3min/5min Total Station Nivo Series Instruction Manual Menu Key Communications To open the Communication menu, press [5] or select Comm. in the Settings menu. Ext.Comm Port Baud Length Parity Stop bit NIKON/SET Serial/Bluetooth (*) 1200/2400/4800/9600/19200/38400 bps 7/8 EVEN/ODD/NONE 1/2 (*) Port selection field appears only when the optional Bluetooth is on-board. Stakeout Press [6] or select Stakeout in the Settings menu to open the Stakeout menu. Add PT Integer between 1 and 999,999 This field sets the default point number to record observed data in stakeout. Unit To open the Unit menu, press [7] or select Unit in the Settings menu. Angle Distance DEG (Degree) GON (GON) MIL (Mil6400) Meter/US-Ft/I-F If you select US-Ft or I-Ft, an additional settings screen appears. Use this screen to specify whether to display values in Decimal-Ft or Ft-Inch. Temp Press °C (Celsius) °F (Fahrenheit) hPa/mmHg/inHg The Angle, Distance, Temp, and Press job settings cannot be changed once a job is created. Total Station Nivo Series Instruction Manual 111 5 Menu Key Recording To open the Rec menu, press [8] or select Angle in the Settings menu. Store DB RAW/XYZ/RAW+XYZ This setting determines whether raw and/or coordinate data is stored when you record SS, CP, or SO records in the Basic Measurement Screen (BMS) or Stakeout screen. Data Rec Internal/COM Set this field to COM to output data on the COM port when you press [ENT] in the BMS or a Stakeout screen. The data is not stored to the job file. For more information, see Outputting data to the COM port, page 82 Others settings To open the Others menu, press [9] or select Others in the Settings menu. XYZ disp 2nd Unit Fast/Norm/Slow/+ENT Defines speed to move to the next screen after showing XYZ of the input PT None/Meter/US-Ft/I-Ft When the Secondary unit is set to a unit, an extra display screen is available in the BMS, stakeout observation screens, and 2-pt reference line screens. The extra screen shows the HD, VD, and SD in the secondary unit. If you select US-Ft or I-Ft, an additional settings screen appears. Use this screen to specify whether to display values in Decimal-Ft or Ft-Inch. Split ST No/Yes Select Yes to separate the point numbers of station points from other record type point numbers If you set the Split ST field to Yes, an additional setting screen appears. Use this screen to specify the starting ST number. 112 Total Station Nivo Series Instruction Manual Menu Key CD Input Language ABC/123 Sets the default input mode when a CD field appears. Select a language from the list. Press [<] / [>] to open the select language screen. Press [^] / [v] to move the cursor to the desired language, and press [ENT] to select it. Reboot confirmation screen appears. Press [ENT] and re-start the instrument, and the selected language will be available. Owner’s Detail Up to 20 characters. Enter your name or the name of your company. If you enter a value in this field, it appears at start-up. Tip – To provide easier configuration for common regional settings, you can quickly configure the Nikon total station to a pre-set combination of default regional settings. For more information, see Changing Regional Configuration Pre-sets, page 25. Tip – The Nikon total station supports up to 3 languages on the instrument. For more information on changing the language settings, see page 113. Total Station Nivo Series Instruction Manual 11 3 5 Menu Key Data Use the Data menu to view or edit records. To display the Data menu, press [4] on the MENU screen. Viewing records You can view data at any time, even in an observation screen or while entering points. Viewing raw data To show the raw data records in a list, press [1] on the Data menu screen. When you first view the raw data, the last four raw records in the current job are displayed. Use [^] or [v] to scroll through the records. To see detailed information for the selected records, press [ENT]. To return to the record list, press [ESC]. SS, CP, F1 records Raw SS, CP and F1 records contain PT, HT, CD, HA, VA, and SD fields. SS records are sideshots (topo shots). All shots from the Basic Measurement Screen (BMS) are stored as SS records. CP records are shots taken in the Angle or Repeat menus, or in the BMS. For more information, see Recording a foresight point after repeat angle measurement, page 52, and Recording data from any observation screen, page 81. When the Store DB setting is set to RAW+XYZ, press [DSP] to switch between the first screen (showing HA, VA, SD, PT, and HT) and the second screen (showing X, Y, Z, PT, and CD). Coordinates are not available in F1 records. When you take more than one measurement to the same point and choose to overwrite the XYZ data, the old raw record becomes raw data only. As a result, only one SS(RAW) record keeps its corresponding SS(XYZ) record. Other SS(RAW) records to the same point no longer have coordinates available. 114 Total Station Nivo Series Instruction Manual Menu Key ST records ST (station) records contain ST, HI, BS, and AZ fields. Press [DSP] to switch between the first screen (showing ST, HI, BS, and AZ) and the second screen (showing X, Y, Z, PT, and CD). When you assign a new ST point name in MENU > Stn Setup > Quick, the coordinates of the station is recorded as (0, 0, 0). SO records SO records are stakeout shots. These are shots recorded in stakeout functions. When the Store DB setting is set to RAW+XYZ, press [DSP] to switch between the first screen (showing HA, VA, SD, PT, and HT), the second screen (showing X, Y, Z, PT, and CD), and the third screen (showing dX, dY, dZ, PT, and CD). The dX, dY, and dZ fields store the difference between the stakeout shot’s actual position and its planned position. These fields are downloaded as comment records in Nikon RAW format. CO records A CO record is a comment added to the job from the system. For example, when you change the Stn-Z using the Remote Benchmark function, or you reset the horizontal angle using the BSCheck function, the system writes a comment record. When you input a Stn-XYZ by Base-XYZ function, the recorded station appears as a comment record. SY records When you complete a station setup, a SY record is stored. This record contains the Temperature, Pressure, and Prism Constant values. Total Station Nivo Series Instruction Manual 11 5 5 Menu Key RM records When you record measurements in RDM (Cont) or RDM (Rad), they are labeled as RM records. Each RM record consists of two screens. Press [DSP] to switch between the first screen (showing From, To, rHD, and rVD) and the second screen (showing rAZ, rSD, rV%, and rGD). When you download data in Nikon RAW format, RM records are output as comment (CO) records. AR records An AR record stores an area and perimeter calculation. When you download data in Nikon RAW format, AR records are output as comment (CO) records. View coordinate data When you press [2] or select XYZ data in the Data menu, coordinate data appears in a list, with the newest record at the bottom of the screen. Use [^] or [v] to scroll through the records. Use [<] or [>] to move up or down one page. Press [ENT] to see more detailed information about the selected record. The header (XYZ,YXZ,NEZ, or ENZ) depends on the Coord. Label setting in MENU > Settings > Coord. For more information, see Coordinate, page 110. UP, MP, CC, and RE records All coordinate records contain PT, CD, X, Y, and Z fields. UP records are uploaded point coordinates. MP records are manually input point coordinates. CC records are points calculated in Cogo, and RE records are points calculated in Resection. 116 Total Station Nivo Series Instruction Manual Menu Key When the Store data setting is set to RAW+XYZ or to XYZ, shots in the BMS (SS records), in various O/S functions (SS records), in 2Pt-RefLine and Arc-RefLine in PRG (SS records) and in some Stakeout functions (SO records) store coordinate records as well. The format of the data is the same as other coordinate records. View records by station To view records by station, press [3] or select ST->SS/SO/CP in the Data menu. A list of all stations appears. Use [^] or [v] to highlight the station name that you want to view. Use [<] or [>] to move up or down one page. To view detailed information about the selected station, press [ENT]. To display all the observation data from the selected station in chronological order, press [ENT] again. Detailed data is as for raw data. For detailed information about each point type and format, see Viewing raw data, page 114. Deleting records Deleting raw records In the RAW screen, use [^] or [v] to highlight the record that you want to delete. Then press the DEL softkey. A confirmation screen appears. To delete the selected record, press [ENT] or the Yes softkey. Total Station Nivo Series Instruction Manual 11 7 5 Menu Key If the Store DB setting is set to Both, the system also deletes the corresponding coordinate data when you delete an SS, SO, or CP record. You can also delete raw data by pressing the DEL softkey in the detailed display screen for the record. Deleting coordinate records In the XYZ screen, use [^] or [v] to highlight the record that you want to delete. Then press the DEL softkey. A confirmation screen appears. To delete the selected record, press [ENT] or the Yes softkey. To cancel the deletion of data, press [ESC] or the No softkey. You can also delete coordinate data by pressing the DEL softkey in the detailed display screen for the record. If the record that you want to delete is referred by an ST record, a confirmation message appears. Deleting station records In the Station screen, use [^] or [v] to highlight the record that you want to delete. Then press the DEL softkey. 118 Total Station Nivo Series Instruction Manual Menu Key A confirmation screen appears. Press [ENT] or the Yes softkey to delete the selected record. A reconfirmation screen appears. Press the DEL softkey to confirm deletion. There is no undelete function on the instrument. Before you press the DEL softkey, make sure that you have selected the correct station record. You cannot press [ENT] in this screen. All observations from the station that you selected are deleted. When you delete a ST record in the raw data view or the station data view, all the observation data from the station is also deleted. Editing records For any point record, you can edit the point name (PT), feature code (CD), height of target (HT), height of instrument (HI), backsight point (BS), and backsight azimuth (AZ). You cannot edit the CD field for SO or F1 records. You cannot edit the HA, VA, or SD values. Editing raw records 1. Do one of the following: – In the RAW screen, highlight the record that you want to edit. Then press the Edit softkey. – In the detailed data screen, press the Edit softkey. Total Station Nivo Series Instruction Manual 11 9 5 Menu Key 2. Use [^] or [v] to highlight a field. Then modify the value in the selected field. When you change the HT of an SS, SO, or CP measurement record, its Z coordinate is recalculated. 3. When you press [ENT] on the last line of the edit screen, a confirmation screen appears. 4. Do one of the following: – To accept the changes and return to the data view screen, press [ENT] or the Yes softkey. – To return to the edit screen, press [ESC] or the No softkey. Editing coordinate records You can edit PT, CD, and coordinate values in coordinate records. You cannot edit the coordinate record for the current station. 1. 120 Do one of the following: – In the XYZ screen, use [^] or [v] to highlight the record that you want to edit. Then press the Edit softkey. – In the detailed data screen, press the Edit softkey. 2. Use [^] or [v] to highlight a field. Then modify the value in the selected field. 3. To finish editing, press [ENT] in the CD field. Total Station Nivo Series Instruction Manual Menu Key A confirmation screen appears. 4. Do one of the following: – To accept the changes and return to the data view screen, press [ENT] or the Yes softkey. – To go back to the edit screen, press [ESC] or the No softkey. Editing station records Note – The system will not recalculate measurements if you change the station record. All coordinate and raw data observed from an edited station record must be recalculated in your postprocessing software. In the RAW screen, use [^] or [v] to highlight the station record that you want to edit. Then press the Edit softkey. You can edit any field in the ST record, but the instrument does not recalculate any measurements from this station. Press [ENT] in the AZ field to confirm the change. If you change the ST or HI values, the coordinates of observation points are not recalculated. A comment record is stored to record the change. The following example shows a comment record for a changed HI value: CO,HI changed at ST:9012 Old HI= 1.345m If you change the BS or AZ values, raw records are not recalculated. A comment record is stored to record the change. Total Station Nivo Series Instruction Manual 121 5 Menu Key Searching records You can search for records by their type, point name, code, or by any combination of these values. Searching raw records In the RAW screen, press the Srch softkey to access the raw data search function. To find a point by name, enter the name in the PT field and press [ENT] twice. You can use the asterisk (*) as a wildcard. For example, when you enter 30* in the PT field, the search matches the points named 300, 301, 302, 3000A2, and 3010. To search by point type, move to the Type field and use [<] or [>] to change the selected point type. The options are ALL, ST, SS, SO, CP, CO, CO(SY), and CO(RDM). If you selected ST, SO or F1 in the Type field, you do not have to enter a value in the CD field. Press [ENT] in the PT field to start the search. If you selected CO, CO(SY), or CO(RDM) in the Type field, you cannot enter a value in the PT or CD fields. Press [ENT] in the Type field to start the search. If more than one point matches the search criteria, the matching points are displayed in a list. Use [^] or [v] to highlight the point you want to use. Then press [ENT] to select it. Detailed data for the selected record appears. Press the DSP softkey to change the fields shown. Press [ESC] to return to the list. 122 Total Station Nivo Series Instruction Manual Menu Key If no point matches the specified criteria, an error screen appears. Press any key to return to the data screen. Searching coordinate records In the XYZ screen, press the Srch softkey to access the XYZ data search function. To find a coordinate by name, enter the name in the PT field and press [ENT] twice. You can use the asterisk (*) as a wildcard. For example, when you enter 500* in the PT field, the search matches the points named 500, 500-1, 500-A, and 5000. To search by point type, move to the Type field and use [<] or [>] to change the selected point type. The options are ALL, MP, UP, CC, and RE. If more than one point matches the search criteria, the matching points are displayed in a list. Use [^] or [v] to highlight the point you want to use. Press [ENT] to select it. Detailed data for the selected record appears. Press the DSP softkey to change the fields shown. Press [ESC] to return to the list. Total Station Nivo Series Instruction Manual 123 5 Menu Key If no point matches the specified criteria, an error screen appears. Press any key to return to the data screen. Entering coordinates In the XYZ screen, press the Input softkey to display a new input point screen. The PT field defaults to the last recorded PT + 1, but you can change the value shown. Enter the PT and CD and then press [ENT] to enter coordinates. Use the numeric keys to enter the coordinates. Press in each field to move to the next field. [ENT] or [v] When you press [ENT] in the CD field, the point is stored as an MP record. After you have recording a point, the next point input screen is shown with the updated default PT. You can record NE, NEZ, or Z-only data to the database. Point name list and code list The instrument stores two list files: a list of PT names and a list of CD names. The structure and functionality of these files is the same. 124 • The PT name list is useful if you have to handle more than one patterns of point names in the field. For example, you may need to use points named 1, 2, 3 …, as well as points named A1, A2, A3 …. • The code list is a prepared list of feature codes. You can use it to store your own codes. Total Station Nivo Series Instruction Manual Menu Key Press [4] or select PT name List in the Data menu to open the point name list. Press [5] or select Code list to open the code list. The point or code names and layers are shown in alphabetic order. Use the four softkeys to customize the list. You can store up to 254 points, codes, or layers in each list. Each list entry can be up to 16 characters long. You can use the first character search to find a point, code, or layer in the list. In the list screen, enter the first character of the name you want to find to jump to that part of the list. For more information, see Advanced feature: Searching for a code by using the first character, page 44. Deleting points, codes, or layers In the point or code list, use [^] or [v] to highlight the item you want to delete. Then press the DEL softkey. A confirmation screen appears. Press [ENT] or the Yes softkey to delete the item. Press [ESC] or the No softkey to cancel the deletion. To delete a whole layer, highlight the layer name in the list and press the DEL softkey. All codes and layers in the selected layer are deleted. Total Station Nivo Series Instruction Manual 125 5 Menu Key Editing an item in the point list or code list Use [^] or [v] to highlight the item that you want to edit. Then press the Edit softkey. An editing screen appears. For points, the Edit Item screen appears. It contains only the PT field. For codes, the Edit Code screen appears, containing the CD field and the REC field. Edit the text shown and then press [ENT]. A confirmation screen appears. Press [ENT] or the Yes softkey to accept the changes and update the list. Edit code list • The Edit Code screen has two fields. The CD field contains the text that appears in the list screen. The REC field is optional. It contains the text that is stored in the job. If you leave the REC field blank, the value in the CD field is used. • You can use the REC field to use familiar words or codes on the screen, but store a numeric code in the job. For example, if you set the CD field to MANHOLE and the REC field to 1155, the text MANHOLE appears on the screen, but the code 1155 is stored. If you press the Edit softkey when a layer name appears, only the Lyr field appears. To save changes to the layer name, press [ENT] in the Lyr field. 126 Total Station Nivo Series Instruction Manual Menu Key Adding a point name In the point list, press the Add softkey to add a new point name to the current layer. Enter a new point name and then press [ENT]. The point name is added to the current layer and the list is updated. Adding a code In the code list, press the Add softkey to add a new feature code to the current layer. Enter the feature code in the CD field. Press [MODE] to change between alphabetic and numeric input mode. You can use the REC field to define a numeric identifier for each feature code. This is optional: If there is a value in the REC field, this value is stored. If you leave the REC field blank, the CD value is stored. Press [ENT] to add the new code and update the code list. Total Station Nivo Series Instruction Manual 127 5 Menu Key Adding a layer 1. In the point or code list, press the Layer softkey. 2. Enter the name of the new layer. 3. To change between alphabetic and numeric input mode, press [MODE]. To store the new layer, press [ENT]. The new layer is added to the list in alphabetic order. Communication Use the Communication menu to download or upload data. To display the Communication menu, press [5] or select Comm. on the MENU screen. Downloading data To go to the download settings screen, press [1] or select Download in the Communication menu. Format Data 128 NIKON SDR2x SDR33 RAW Coordinate To display the total number of records that will be downloaded, press [ENT] in the Data field. Total Station Nivo Series Instruction Manual Menu Key Optional Bluetooth function When the optional Bluetooth is installed, Port selection screen appears when pressing the Comm softkey. As each record in the current job is output from the instrument (downloaded), the current line number is updated. After downloading is completed, you can choose to delete the current job. To delete the current job, press [4]. To return to the Basic Measurement Screen (BMS), press [ESC] or the Abrt softkey. Uploading coordinate data To upload coordinate data from a computer, press [2] or select Upload XYZ in the Communication menu. The default data format appears. To change the order of data fields, press the Edit softkey. For more information, see Advanced feature: Editing the data order for upload, page 130. Otherwise, just press [ENT]. Press the Job softkey to go to the Job Manager screen. For more information, see Job Manager, page 92. To change the communication settings, press the Comm softkey. The serial port settings must match the settings used by the terminal software on the computer. Port selection field appears in the Communication menu only when the optional Bluetooth is on-board. Total Station Nivo Series Instruction Manual 129 5 Menu Key Use an RS-232C cable to connect the instrument to the computer. The Free space field shows the number of points that can be stored. Press [ENT] to put the instrument in receive mode. Then use the Send Text File command in the terminal program on the computer to start sending data. In the terminal program, set flow control to Xon/Xoff. As each point is received by the instrument, the value in the Records field is incremented. If you press [ESC] during data upload, the upload is canceled and the display returns to the Communication menu. Records that were received before you pressed [ESC] are stored in the job. The system truncates any code that is longer than 16 characters. Duplicate points If the existing point is a UP, CC, or MP record, and it is not referred to by any ST or BS, it is automatically overwritten by the uploaded point. No error message appears. Advanced feature: Editing the data order for upload 1. To open the Data Fields screen, press the Edit softkey. 2. To move between the fields, press [<] or [>]. 3. To change the selected item in a field, use the and softkeys. The options are PT, N, E, Z, CD, or blank. 4. To save your changes and return to the previous screen, press the Save softkey. For example, if your original data is as follows: 1, UB, 30.000, 20.000, L1 and you set the data fields to PT N E CD, then the uploaded data is: PT=1, N=30.000, E=20.000, CD=L1 130 Total Station Nivo Series Instruction Manual Menu Key Uploading coordinates without points You can upload data without points. If you do not include a point in the format definition, each line of data is automatically assigned the next available point number. To help you to select points in the field, make sure that you store an identifier in the CD field. The data format cannot include duplicate items. Use PT, N, E, Z and CD once each in the data format. To skip some items in your original file, set the corresponding field to blank. Uploading a point name list or code list When you upload a code list, it always replaces the existing code list on the instrument. To upload a point name list via cable, press [3] or select PT List in the Communication menu. To upload a code list, press [4] or select Code List. Connect the RS-232C cable. Start a terminal program on the computer. To put the instrument into receive mode, press [ENT] or the OK softkey. The counter is updated as each line in the list is stored. You can store up to 254 codes or point names. If a code or point name is longer than 16 characters, it is truncated. 1sec-Keys Use the 1sec-Keys menu to configure the settings for the one-second keys, [MSR], [DSP], [USR], [S-O], and [DAT]. To access this menu, press [6] or select 1sec-Keys in the MENU screen. Total Station Nivo Series Instruction Manual 131 5 Menu Key [MSR] key settings To change settings for the [MSR1] and [MSR2] keys, press [1] or select [MSR] in the 1sec-Keys menu. There are two [MSR] keys: • To change the settings for the [MSR1] key, press [1] or select MSR1. • To change the settings for the [MSR2] key, press [2] or select MSR2. Each [MSR] key has five settings. In the Const and AVE fields, use the numeric keys to enter values. In the other fields, use [<] or [>] to change the settings. Tip – You can also access the settings screen by holding down [MSR1] or [MSR2] for one second. [DSP] key settings To change the display items in the BMS and in Stakeout observation screens, press [2] or select [DSP] in the 1sec-Keys menu. To move the cursor, use [<], [>] , [^], or [v]. To change the display item, press either the softkey or the softkey. To save the changes, press [ENT] at the last line ofor press the Save softkey. Tip – You can also access the DSP settings screen by holding down [DSP] for one second. [USR] key settings To change the functions that are assigned to the [USR1] and [USR2] keys, press [3] or select [USR] in the 1sec-Keys menu. 132 Total Station Nivo Series Instruction Manual Menu Key There are two [USR] keys. The function that is assigned to each key appears beside the key name. – To change the settings for the [USR1] key, press [1] or select USR1. – To change the settings for the [USR2] key, press [2] or select USR2. In the Select Functions screen, the asterisk (*) indicates the function that is currently assigned to the key. To highlight a function, use [^] or [v]. To assign that function to the selected [USR] key, press [ENT]. [S-O] key settings To enter the Stakeout settings screen, press [4] or select [S-O] in the 1sec-Keys menu. There are two Stakeout settings. For more information, see Stakeout, page 111. [DAT] key settings 1. To change the settings for the [DAT] key, press [5] or select [DAT] in the 1sec-Keys menu. The asterisk (*) indicates the currently selected view format. 2. To move the cursor, use [^] or [v]. 3. To change the format displayed by [DAT], press [ENT]. Total Station Nivo Series Instruction Manual 133 5 Menu Key Calibration Use the Calibration screen to calibrate the instrument. To open the Calibration screen, press [7] or select Calibrat. on the MENU screen. For more information, see Adjusting, page 138. Time Use the Date & Time screen to set the current date and time. 1. To open the Date & Time screen, press [8] or select Time on the MENU screen. The current date and time settings are displayed. 2. Enter the date in Year-Month-Day format. For example, to change the date to June 18, 2008, press [2] [0] [0] [8] [ENT] [6] [ENT] [1] [8] [ENT]. If the highlighted part of the field (for example, the year) is already correct, you can just press [ENT] to use the current value. For example, if the date is already set to June 24, 2008, and you want to change the date to June 18, 2008, press [ENT] [ENT] [1] [8] [ENT]. 134 3. To move to the Time field, press [ENT] in the Date field. 4. Enter the time in 24-hour format. For example, to set the time to 4:35 PM, press [1] [6] [ENT] [3] [5] [ENT]. 5. Do one of the following: – To finish setting the date and time, press [ENT] in the Minutes field. – To cancel the input, press [ESC]. Total Station Nivo Series Instruction Manual CHAPTER Checking and Adjustment In this chapter: Adjusting the Electronic Level Checking and Adjusting the Circular Level Checking and Adjusting the Optical/Laser Plummet Zero Point Errors of Vertical Scale and Horizontal Angle Corrections Checking the Instrument Constant Checking the Laser Pointer Total Station Nivo Series Instruction Manual 135 6 Checking and Adjustment Adjusting the Electronic Level Adjustment of the electronic level is done by Zero point errors of vertical scale and horizontal angle corrections. For detailed instruction, please see page 137. Checking and Adjusting the Circular Level Once you have checked and adjusted the electronic level, check the circular level. If the bubble is not in the center of the level, use the adjusting pin to rotate the three adjustment screws of either circular level on the instrument main body or tribrach until the bubble is centered. Checking and Adjusting the Optical/Laser Plummet The optical axis of the plummet must be aligned with the vertical axis of the instrument. To check and adjust the optical/laser plummet: 1. Place the instrument on the tripod. You do not have to level the instrument. 2. Place a thick sheet of paper marked with an X on the ground below the instrument. While you are looking through the optical plummet, adjust the leveling screws until the image of the X is in the center of the reticle mark . For laser plummet, adjust the laser pointer to the X. 3. Rotate the alidade 180°. If the marked image is in the same position in the center of the reticle mark, no adjustment is required For laser plummet, if the laser pointer is on the X, no adjustment is required. 136 Total Station Nivo Series Instruction Manual Checking and Adjustment 4. If the image or laser pointer is not in the same position, adjust the optical or laser plummet: a. Use the supplied hexagonal wrench to turn the adjustment screws until the image of the X is in Position P. Position P is the center point of the line connecting the X and the center of the reticle mark . b. Repeat from Step 2. For laser plummet adjustment, a cap needs to be removed. Zero Point Errors of Vertical Scale and Horizontal Angle Corrections Checking 1. Set up the instrument on the tripod. 2. Follow the leveling procedures described in Leveling, page 15. 3. Flip the telescope to the Face-1 position. 4. Sight a target that is within 45° of the horizontal plane. 5. Read the vertical angle from the VA1 field in the Basic Measurement Screen (BMS). 6. Rotate the instrument 180° and flip the telescope to the Face-2 position. 7. Read the vertical angle from the VA2 field. 8. Add the two vertical angles together, VA1 + VA2. – No adjustment is required if the zero reference for vertical angles (VA zero setting) is set to Zenith, and VA1 + VA2 equals 360°. – No adjustment is required if the zero reference for vertical angles (VA zero setting) is set to Horizon, and VA1 + VA2 is either 180° or 540°. – An adjustment is required if VA1 + VA2 is not one of the values listed above. Note – The difference between the vertical angle reading the relevant angle (either 360° for Zenith, or 180° or 540° for Horizon) is called the altitude constant. Total Station Nivo Series Instruction Manual 137 6 Checking and Adjustment Adjusting To enter the calibration screen, press [MENU] and [7]. 1. The Nivo series has two-axis level compensation.Take an F1 measurement to a target on the horizon. Press [ENT]. The vertical angle is shown in the V0 dir= Horiz setting. VA1 HA1 X1 Face-1 vertical angle (tilt-off value) Face-1 horizontal angle (tilt-off value) Face-1 X axis tilt value Face-1 Y axis tilt value Y1 When you have taken the measurement, the message on the bottom line changes from DO NOT TOUCH! to Turn to F2. 2. Take an F2 measurement to the same target. Press [ENT]. VA2 HA2 X2 Face-2 vertical angle (tilt-off value) Face-2 horizontal angle (tilt-off value) Face-2 X axis tilt value Face-2 Y axis tilt value Y2 When the observation on F2 is completed, four parameters are displayed. 3. Do one of the following: – To return to the first observation screen, press [ESC] or the Redo softkey. – To set parameters on the instrument, press [ENT] or the OK softkey. IIf ACV, ACH, X, or Y is out of range, OVER appears. Press any key to return to the first observation screen. 138 Total Station Nivo Series Instruction Manual Checking and Adjustment Checking the Instrument Constant The instrument constant is a numerical value used to automatically correct for the displacement between the mechanical and electrical centers when measuring distances. The instrument constant is set by the manufacturer before the instrument is shipped. However, to ensure the highest operational accuracy, we recommend that you check the instrument constant several times a year. To check the instrument constant, you can either compare a correctly measured base line with the distance measured by the EDM, or follow the procedure below. About 100 m To check the instrument constant: 1. Set up the instrument at Point P, in as flat an area as possible. 2. Set up a reflector prism at Point Q, 100 m away from Point P. Make sure that you take the prism constant into account. 3. Measure the distance between Point P and Point Q (PQ). 4. Install a reflector prism on the tripod at Point P. 5. Set up another tripod at Point R, on the line between Point P and Point Q. 6. Transfer the Nivo series instrument to the tripod at Point R. 7. Measure the distance from Point R to Point P (RP), and from Point R to Point Q (RQ). 8. Calculate the difference between the value of PQ and the value of RP + RQ. 9. Move the Nivo series instrument to other points on the line between Point P and Point Q. 10. Repeat Step 5 through Step 9 ten times or so. 11. Calculate the average of all the differences. The error range is within 3 mm. If the error is out of range, contact your dealer. Total Station Nivo Series Instruction Manual 139 6 Checking and Adjustment Checking the Laser Pointer The Nivo series total station uses a red laser beam to a laser pointer. The laser pointer is coaxial with the line of sight of the telescope. If the instrument is well adjusted, the red laser pointer coincides with the line of sight. External influences such as shock or large temperature fluctuations can displace the red laser pointer relative to the line of sight. 140 Total Station Nivo Series Instruction Manual CHAPTER Specifications In this chapter: Main Body Standard Components External Device Connector Total Station Nivo Series Instruction Manual 141 7 Specifications Main Body Telescope Tube length 125 mm (4.91 in.) Magnification 30 X Effective diameter of objective 45 mm (1.77 in.) EDM 50 mm (1.97 in.) Image Erect Field of view 1°20' 2.3 m at 100 m (2.3 ft at 100 ft) Resolving power 3.0'' Focusing distance 1.5 m to infinity (4.92 ft to infinity) Measurement range Distances shorter than 1.5 m (4.92 ft) cannot be measured with this EDM. Measurement range with no haze, visibility over 40 km (25 miles)) Prism mode Reflector sheet (5 cm x 5 cm) 300 m (984 ft) Standard prism (1P) 5,000 m (16,400 ft) Reflectorless mode Reference target 300 m (984 ft) • The target should not receive direct sunlight. • “Reference target” refers to a white, highly reflective material. (KGC90%) • The maximum measurement range is 500 m in the reflectorless mode. Distance precision Precise mode Prism ± (3 + 2 ppm × D) mm (–10 °C to +40 °C) ± (3 + 3 ppm × D) mm (–20 °C to –10 °C, +40 °C to +50 °C) Reflectorless ± (3 + 2 ppm × D) mm (–10 °C to +40 °C) ± (3 + 3 ppm × D) mm (–20 °C to –10 °C, +40 °C to +50 °C) Normal mode 142 Prism ± (10 + 5 ppm × D) mm Reflectorless ± (10 + 5 ppm × D) mm Total Station Nivo Series Instruction Manual Specifications Measurement intervals Measurement intervals may vary with the measuring distance or weather conditions. For the initial measurement, it may take few more seconds. Precise mode Prism 1.5 sec. Reflectorless 1.8 sec. Normal mode Prism 0.8 sec. Reflectorless 1.0 sec. Prism offset correction –999 mm to +999 mm (1 mm step) Angle measurement Reading system Nivo 3.M Nivo5.M Absolute encoder Diametrical reading on HA Single reading on VA Single reading on HA/VA Minimum display increment 360° 1''/5''/10" 400G 0.2 mgon/1 mgon/2 mgon MIL6400 0.005 MIL/0.02 MIL/0.05 MIL DIN18723 accuracy Nivo3.M: 3" / 1.0 mgon Nvo5.M: 5"/1.5 mgon Tilt sensor Method Liquid-electric detection (Dual axis) Compensation range ±3' Tangent screw Type Friction clutch endless fine motion Tribrach Type Detachable Total Station Nivo Series Instruction Manual 143 7 Specifications Level Electronic level Displayed on the LCD Circular level vial Sensitivity 10'/2 mm Optical plummet Image Erect Magnification 3× Field of view 5° Focusing range 0.5 m (1.6 ft) to infinity Optional laser plummet Wave length 635 nm Laser class Class 2 Focusing range ∞ Laser diameter Approx. 2 mm Display and keypad Display type Graphical LCD Resolution 128 × 64 Display illumination Backlight Keys 25 Connections in the base of instrument Communications Type RS-232C Maximum baud rate 38400 bps asynchronous External power supply input voltage 144 Total Station Nivo Series Instruction Manual 4.5 V to 5.2 V DC Specifications Battery pack Output voltage 3.8 V DC rechargeable Continuous operation time Continuous distance/angle measurement 10 hours Distance/angle measurement every 30 seconds 16 hours Continuous angle measurement 30 hours Tested at 25 °C (nominal temperature). Operation times may vary depending on the condition and deterioration of the battery. Environmental performance Operating temperature range –20 °C through +50 °C (–4 °F through +122 °F) Storage temperature range –25 °C through +60 °C (–13 °F through +140 °F) Dimensions Main unit 149 mm W x 145 mm D x 306 mm H Carrying case 435 mm W x 206 mm D x 297 mm H Weight Main unit w/o battery 3.5 kg (7.95 lbs), approx. Battery 0.1 kg (0.22 lbs), approx. Carrying case 2.4 kg (5.28 lbs), approx. Charger and AC adapter 0.4 kg (0.99 lbs), approx. Environmental protection Watertight/dust-proof protection IP66 Total Station Nivo Series Instruction Manual 145 7 Specifications Standard Components • Instrument main body • Battery pack (X 2) • Universal charger, power cord, and adapters • Adjustment pin, Allen wrench • Objective lens cap • Vinyl cover • Total Station Nivo Series Instruction Manual (this document) • Carrying case • Shoulder strap (X 2) External Device Connector This connector can be used to connect to an external power source or to communicate with an external device. Before using the external device connector, make sure that the external device meets the specifications below. 146 Input voltage 4.5 V to 5.2 V DC System RS-232C Signal level ±9 V standard Maximum baud rate 38400 bps asynchronous Compatible male connector Hirose HR10A-7P-6P or HR10-7P-6P CAUTION – Except for the connection shown in Figure 8.1on page 150, use of this connector is at your own risk. CAUTION – Use only the male connectors specified above. Using other connectors will damage the instrument. Total Station Nivo Series Instruction Manual Specifications The external device connector is a Hirose HR 10A-7R-6S female connector. The pinouts for connecting it to an external device connector are shown below: Pin Signal Description RXD Receive data (Input) TXD Send data (Output) NC No connection Power GND Ground NC No connection HRS CAUTION – Use only the pin connections shown above. Using other connections will damage the instrument. CAUTION – The Nivo series total station has different pin assignment from other models of Nikon total station. To connect to an external power source, supply power to Pin 4 (power terminal) and Pin 5 (ground terminal) on the instrument. The instrument will use the external power source even if the internal battery packs are attached. CAUTION – Make sure that the power supplied is within the rated input range (4.5 V to 5.2 V DC, 1 A maximum). Power supplied outside this range will damage the instrument. To communicate with an external device, connect the RS-232C signal from the external device to Pin 1 (input terminal) and to Pin 2 (output terminal) on the instrument. Cap the data output/external power input connector securely while not in use. The instrument is not watertight if the cap is not attached or not attached securely, and when the data output/external power input connector is in use. The instrument can be damaged by static electricity from the human body discharged through the data output/external power input connector. Before handling the instrument, touch any other conductive material once to remove static electricity. Total Station Nivo Series Instruction Manual 147 7 148 Specifications Total Station Nivo Series Instruction Manual CHAPTER System Diagrams In this chapter: System Components Total Station Nivo Series Instruction Manual 149 8 System Diagrams System Components Tubular Compass Tubular compass attachment Battery charger AC adapter and plug adapter Nivo series Solar filter Diagonal eyepiece Connecting cable (9 pin, USB) Low-power eyepiece Personal computer Figure 8.1 150 Measurement side Total Station Nivo Series Instruction Manual High-power eyepiece System Diagrams Coaxial target plate for single prism Target pole Mini prism C Mini prism holder Standard round single prism C Tiltable single prism holder Mini prism adapter Triple prism holder Prism adapter Height adjustment adapter is not used. Tribrach adapter 15 Tribrach W30/W30b Telescopic prism pole Figure 8.2 Tripod for telescopic prism pole Nikon tripod Prism reflector side Note – Nivo series must be used with the Tribrach W30 or W30b. Total Station Nivo Series Instruction Manual 151 8 152 System Diagrams Total Station Nivo Series Instruction Manual CHAPTER Communications In this chapter: Uploading Coordinate Data Uploading Point Lists and Code Lists Downloading Data Total Station Nivo Series Instruction Manual 153 9 Communications Uploading Coordinate Data Settings To configure the transmission speed and other settings, go to MENU > Settings > Comm. For more information, see Communications, page 111. Record format You can upload coordinate records in the following formats: PT PT PT PT 154 PT PT CD PT PT PT PT CD CD CD Total Station Nivo Series Instruction Manual CD Communications The record formats shown above use the following codes: Code Description Length PT Point number Up to 20 digits Actual X coordinate Variable length Actual Y coordinate Variable length Actual Z coordinate Variable length CD Feature code Up to 16 characters Data example 20100,6606.165,1639.383,30.762,RKBSS 20104,1165611.6800,116401.4200,00032.8080 20105 5967.677 1102.343 34.353 MANHOLE 20106 4567.889 2340.665 33.444 PT1 20107 5967.677 1102.343 34.353 20109,4657.778,2335.667,,PT2 20111,4657.778,2335.667 20113 4657.778 2335.667 20115,,,34.353,MANHOLE 20117,,,33.444 Total Station Nivo Series Instruction Manual 155 9 Communications Uploading Point Lists and Code Lists Settings To configure the transmission speed and other settings, go to MENU > Settings > Comm. For more information, see Communications, page 111. File format PT lists and code lists use the same record format. Use the filenames POINT.LST for a PT list, and CODE.LST for a code list. DEFAULT String1 , Code1 Layer2 String2-1, Code2-1 String2-2, Code2-2 Layer3 Layer 3-1 String3-1-1, Code3-1-1 String3-1-2, Code3-1-2 String3-2, Code3-2 String3-3, Code3-3 String4, Code4 String5, Code5 String6, Code6 String7, Code7 Figure 9.1 156 Record format for PT lists and code lists Total Station Nivo Series Instruction Manual The first line of the file must contain the text “DEFAULT” in capital letters. Curly brackets { } group items together under the preceding line. For example, Layer 3-1 contains String 3-1-1 and String 3-1-2. Layer 3 contains the five items from Layer 3-1 to String 3-3. “String” represents characters that are displayed on the screen. “Code” represents characters that are stored in the database. Communications Data example DEFAULT “STRUCTURES” “TREE”, “S0001” “FENCE”, “S0002” “MAIL BOX”, “S0003” “FLOWER BED”, “S0004” “ROADS” “MANHOLE”, “R0001” “CENTER LINE” “WHITE”, “R002-W” “YELLOW”, “R002-Y” “SIDEWALK”, “R0003” “CROSSING”, “R0004” “BRIDGE”, “R0005” “SIGNAL”, “R0006” “HIGHWAY STAR”, “R0007” “RAILWAY” “CROSSING”, “RW001” “STATION”, “RW002” “SIGNAL”, “RW003” “BRIDGE”, “RW004” “TUNNEL”, “RW005” Total Station Nivo Series Instruction Manual 157 9 Communications Downloading Data Settings To configure the transmission speed and other settings, go to MENU > Settings > Comm. For more information, see Communications, page 111. Nikon raw record formats Coordinate records type , pt , (pt id) , northing , easting , elevation , code type pt (pt id) northing One of the following codes: UP Uploaded point MP Manually input point CC Calculated coordinate RE Resection point Point number (Point ID) Northing of the coordinate easting elevation code Easting of the coordinate Elevation of the coordinate Feature code Station records ST , stnpt , (stnid) , bspt , (bs id) , hi , bsazim , bsha ST stnpt (stn id) bspt (bs id) hi bsazim bsha 158 Station record identifier (fixed text) Station point number (Station ID) Backsight point number (Backsight ID) Height of instrument Backsight azimuth Backsight horizontal angle Total Station Nivo Series Instruction Manual Communications Control point records CP , pt , (pt id) , ht , sd , ha , va , time , code CP pt (pt id) ht sd ha va time code Control point record identifier (fixed text) Point number (Point ID) Height of target Slope distance Horizontal angle Vertical angle 24-hour time stamp Feature code Sideshot records SS , pt , ht , sd , ha , va , time , code SS pt ht sd ha va time code Sideshot record identifier (fixed text) Point number Height of target Slope distance Horizontal angle Vertical angle 24-hour time stamp Feature code Stakeout records SO , pt , (sopt) , ht , sd , ha , va , time , SO pt (sopt) ht sd ha va Stakeout record identifier (fixed text) Recorded point number (Original number of point staked) Height of target Slope distance Horizontal angle Vertical angle time 24-hour time stamp Total Station Nivo Series Instruction Manual 159 9 Communications F1 records face , pt , ht , sd , ha , va , time face pt ht sd ha va time One of the following: F1 Shot taken using Face-1 (fixed text) Shot taken using Face-1 for Station setup (fixed text) Point number Height of target Slope distance Horizontal angle Vertical angle 24-hour time stamp Comment/note records CO , text CO text 160 Comment record identifier (fixed text) Comment text Total Station Nivo Series Instruction Manual Communications SDR2x and SDR33 record formats Header record 00NM ver 0000 1–4 5–20 00NM ver 21–24 25–40 41 0000 datetime ang 42 dist 43 press 44 temp 45 coor 46 datetime ang dist press temp coor Header record identifier (fixed text) SDR download version. One of the following: SDR20V03-05 SDR2x SDR33V04-01 SDR33 Not used Download date and time (in hours and minutes) Angle units. One of the following: Degrees Gons Mils Distance units. One of the following: Meters Feet Pressure units. One of the following: mm Hg In. Hg hPa Temperature units. One of the following: Celsius Fahrenheit Coordinate order. One of the following: NEZ ENZ Not used Instrument record 01KI1 1–5 6–21, 28–43 22–27, 44–49 50 51 52–61, 62–71, 72–81, instr serNo Instr serNo 1 zero VA 0.000 0.000 0.000 01KI1 instr Instrument record identifier (fixed text) Instrument make and model serNo Instrument serial number zero VA 0.000 0.000 Not used The reference point for vertical angles. One of the following: Zenith Horizon Not used Not used 0.000 Not used Total Station Nivo Series Instruction Manual 161 9 Communications Station details record 02KI stnpt 1–4 5–8 (2x), 5–20 (33) 9–18 (2x), 21–36 (33) 19–28 (2x), 37–52 (33) 29–38 (2x), 53–68 (33) 39–48 (2x), 69–84 (33) 49–64 (2x), 85–100 (33) northing easting elevation hi desc 02KI stnpt Station details record identifier (fixed text) Station point number northing Northing of station easting Easting of station elevation Elevation of station hi Height of instrument desc Station description Target details record 03NM ht 1–4 5–14 (2x), 5–20 (33) 03NM ht Target details record identifier (fixed text) Height of target Backsight bearing details record 07KI 162 stnpt bspt bsazim ha 1–4 07KI 5–8 (2x), 5–20 (33) 9–12 (2x), 21–36 (33) 13–22 (2x), 37–52 (33) 23–32 (2x), 53–68 (33) stnpt Backsight bearing details record identifier (fixed text) Station point number bspt Backsight point number bsazim Backsight azimuth ha Horizontal angle Total Station Nivo Series Instruction Manual Communications Coordinates record 08KI pt northing 1–4 5–8 (2x), 5–20 (33) 9–18 (2x), 21–36 (33) 19–28 (2x), 37–52 (33) 29–38 (2x), 53–68 (33) 39–54 (2x), 69–84 (33) easting elevation desc 08KI pt Coordinates record identifier (fixed text) Point number northing Northing of the coordinate easting Easting of the coordinate elevation Elevation of the coordinate desc Feature code Observation record 09MC stnpt pt sd va ha desc 1–4 09MC Observation record identifier (fixed text) 5–8 (2x), 5–20 (33) 9–12 (2x), 21–36 (33) 13–22 (2x), 37–52 (33) stnpt Station point number pt Observed point number sd Slope distance 23–32 (2x), 53–68 (33) 33–42 (2x), 69–84 (33) 43–58 (2x), 85–100 (33) va Vertical angle ha Horizontal angle desc Feature code Total Station Nivo Series Instruction Manual 163 9 Communications Job identifier record 10NM jobid 1–4 5–8 (2x), 5–20 (33) 1 incZ 10NM jobid T&Pcorr C&Rcorr refcon sealev Job identifier record ID (fixed text) Job name/title Note – The following fields occur only in SDR33 format. 21 22 incZ Point ID length option 2D or 3D coordinates. One of the following: 2D 3D 23 T&Pcorr 24 C&Rcorr 25 refcon 26 sealev Atmospheric correction. One of the following: Off On Curvature and refraction correction. One of the following: Off On Refraction constant. One of the following: 0.132 0.200 Sea level correction. One of the following: Off On Note record 13NM 1–4 5–64 164 note 13NM note Total Station Nivo Series Instruction Manual Note record ID (fixed text) Note text Communications Data examples Nikon raw data format CO,Nikon RAW data format V2.00 CO,EXAMPLE5 CO,Description: SAMPLE DATA OF DOWNLOAD CO,Client: CO,Comments: CO,Downloaded 22-JUL-2008 18:56:10 CO,Software: Pre-installed version: 1.0.0.1 CO,Instrument: Nivo 5.M CO,Dist Units: Metres CO,Angle Units: DDDMMSS CO,Zero azimuth: North CO,Zero VA: Zenith CO,Coord Order: NEZ CO,HA Raw data: Azimuth CO,Tilt Correction: VA:ON HA:ON CO, EXAMPLE5 Created 22-JUL-2008 07:09:21 CO,S/N:213705 MP,1,,100.000,200.000,10.000, CO,Temp:20C Press:760mmHg Prism:0 22-JUL-2008 07:11:34 ST,1,,,,1.400,55.4500,55.4500 F1,,,,0.0000,90.0000,8:27:58 SS,3,1.200,330.706,326.027,20.320,07:13:46,SIGN SS,4,1.250,379.193,300.847,29.084,07:14:24,TREE SS,5,1.218,363.344,328.032,30.105,07:14:57,TREE R SO,1003,,1.240,331.220,326.783,19.998,07:18:17, Nikon coordinate data format 1,100.0000,200.0000,10.0000, 2,200.0000,300.0000,20.0000, 3,116.9239,216.9140,11.8425,TRAIN PLATFORM 4,126.6967,206.2596,11.2539,RAMP 11,100.0045,199.9958,10,0000, 13,116.9203,216.9113,11.7157, 14,126.6955,206.2579,10.9908, 21,100.0103,199.9958,10.0000, 31,100.0013,200.0005,10.0000, 41,100.0224,200.0331,9.9000, 43,116.9263,216,9165,11.8016,CURB 44,126.7042,206.2871,10.8193,DITCH 45,116.9266,216.9160,11.8028, 46,126.7046,206.2845,10.8213,CP POINT Total Station Nivo Series Instruction Manual 165 9 Communications SDR2x raw data format 00NMSDR20V03-05 000023-Jul-2008 18:39:111211 10NMEXAMPLE6 01KI1 Nikon Nivo 5.M 000000 Nikon Nivo 5.M 00000012 0.000 13NMDownloaded 23-Jul-2008 18:39:22 13NMSftware: Pre-install version: 1.0.0.1 13NMInstrument: Nikon Nivo 5.M 13NMDist Units: Metres 13NMAngle Units: Degrees 13NMZero azimuth: North 13NMZero VA: Horizon 13NMCoord Order: NEZ 13NMClient: 13NMDescription: 13NMTilt Correction: VA:ON HA:ON 13NM EXAMPLE6 Created 23-Jul-2008 07:09:21 08KI0001100.000 200.000 10.000 08KI0002200.000 300.000 20.000 02KI0001100.000 200.000 10.000 0.100 07KI0001000245.0000 0.0000 13F100000002 0.0000 13F200000002 179.9639 13NMBS Check HA:359.3525 Reset to HA: 0.0000 07:21:41 13F10000000323.990 4.1694 0.0000 13F20000000323.990 175.8403 180.0028 03NM0.000 13F10001000323.990 4.1653 359.9833 MAIN PLATFORM 13F10001000427.445 2.4097 328.1958 RAMP 13NMStart of 2-Pt Resection 13F10000000427.445 2.4097 0.0000 13F10000000323.991 4.1542 31.8042 13F10000000427.430 1.8583 121.4306 13F10000000323.976 3.8625 153.2306 08KI0011100.005 199.996 10.000 02KI0011100.005 199.996 10.000 0.100 07KI0011000344.9980 0.0000 166 Total Station Nivo Series Instruction Manual 0.000 0.000 Communications SDR2x coordinate data format 00NMSDR20V03-05 000023-Jul-2008 18:40:111211 10NMEXAMPLE6 01KI1 Nikon Nivo 5.M 000000 Nikon Nivo 5.M 00000012 0.000 13NM 080926-2 Downloaded 08-Oct-2008 18:40:06 13NMSftware: Pre-install version: 1.0.0.1 13NMInstrument: Nikon Nivo 5.M 13NMDist Units: Metres 13NMAngle Units: Deqrees 13NMZero azimuth: North 13NMZero VA: Horizon 13NMProjection correction: OFF 13NMC&R correction: OFF 13NMSea level correction: OFF 13NMCoord Order: NEZ 13NMClient: 13NMDescription: 13NMTilt Correction: VA:OFF HA:OFF 13NM EXAMPLE6 Created 23-Jul-2008 07:09:21 13NMPrism constant: 0 08KI0001100.000 200.000 10.000 08KI0002200.000 300.000 20.000 13NMBacksight Check to Pt:2 HA:359.3525 07:21:39 13NMBacksight Pt:2 Reset to HA: 0.0000 07:21:41 08KI0003116.924 216.914 11.843 MAIN PLTFORM 08KI0004126.697 206.260 11.254 RAMP 13NMStart of 2-Pt Resection 08KI0011100.005 199.996 10.000 0.000 0.000 Total Station Nivo Series Instruction Manual 167 9 168 Communications Total Station Nivo Series Instruction Manual CHAPTER 10 Error Messages 10 In this chapter: Cogo Communications Data Job Manager Programs Recording Data Searching Settings Stakeout Station Setup System Error Total Station Nivo Series Instruction Manual 169 10 Error Messages Cogo NO Result 100.1 The system was unable to calculate an area because points were not entered in the correct order. Press any key to return to the Cogo menu. Then enter the points in the correct order. Same Coordinate 100.2 The point or coordinate that you entered is identical to the previous input point. Press any key to return to the point input screen. Then use a different point. XY-coordinate is required 100.3 The input point does not have XY (NE) coordinates. Press any key to return to the point input screen. Then enter a point that has X and Y coordinates. Communications If an error is detected during uploading of data, the Nivo instrument aborts the upload process and displays one of the following messages. Check Data 100.4 There are errors in the uploaded data. The uploaded data contains errors, such as an alphabetic character in a coordinate field. Press any key. Then check the specified line in the data. DUPLICATE PT 100.5 The uploaded data contains a duplicate PT. Press any key. Then check the specified point in the data. Tip – If the existing point is a UP, CC, or MP record, and is not referred by ST or BS, then it will be overwritten by the uploaded record. No error message appears. PT MAX20 chars 100.6 The uploaded data contains a PT with a name or number that is longer than 20 digits. Press any key. Then check the specified line in the data. XYZ OVERRANGE The uploaded data contains a coordinate that is longer than 13 digits. Press any key. Then check the specified line in the data. 170 Total Station Nivo Series Instruction Manual 100.7 Error Messages 10 Data Can't Edit Current ST 100.8 You have tried to edit the current ST. Note – You cannot edit the current ST. However, old ST records can be edited. No recalculation can be performed on the instrument. Press any key to return to the code/layer name input screen. Can't Edit ST/BS refer to this PT 100.9 You have tried to edit a coordinate that the current ST or BS refers to. You cannot change a coordinate if the current ST or BS refers to it. Press any key to return to the Data view screen. Can't Edit XYZ from measurement 100.10 You have tried to change the coordinates of an SO, SS, or CP record. You cannot change the coordinates of an SO, SS, or CP record. Press any key to return to the previous screen. DELETE Stn-XYZ 100.11 You have tried to delete a coordinate record that the current ST or BS refers to. You must confirm that you want to delete a coordinate record that the current ST or BS refers to. To ... Press ... delete XYZ the DEL softkey return to the previous screen without deleting XYZ [ESC] or the Abrt softkey Total Station Nivo Series Instruction Manual 171 10 Error Messages Job Manager Cannot Assign 100.12 You have tried to set the current job as the control file. Press any key to return to the previous screen. Then select a different job. Can't Create 100.13 There is no space available to create a job or record a point. Press any key to return to the Job Manager. Then use the DEL softkey to delete old jobs. Existing Job 100.14 You have entered an existing job name for a new job. Press any key and then change the name for the new job. MAX 32Jobs 100.15 You are trying to create a new job when the maximum number of jobs (32) is already stored. Press any key to return to the Job Manager. Then use the DEL softkey to delete old jobs. Programs NO Stn Setup 100.16 You did not perform a station setup or BS check before entering the Programs function. To ... Press ... go to the Stn Setup menu [2] or select Stn Setup return to the BMS [ESC] go to the Programs menu [1] or select Continue Tip – Selecting Continue does not resume the last ST record. You should only use the Continue option if you are sure that the previous ST coordinates and the current HA orientation are correct. Otherwise, records in the Programs function may not be correct. XY&Z coordinate are required Three-dimensional coordinates are required in S-Plane function. Press any key to return to the point input screen. Then enter a three-dimensional point. 172 Total Station Nivo Series Instruction Manual 100.17 Error Messages 10 Recording Data DATA FULL 100.18 The data storage is full. Press any key to return to the Basic Measurement Screen (BMS). Then: To ... Go to ... delete unnecessary data MENU > Data delete jobs MENU > Job DUPLICATE PT 100.19 The input PT you are trying to record already exists in the current job. An existing coordinate record cannot be overwritten by measured data. Press any key to return to the point input screen. Change PT. Duplicate PT 100.20 The input PT you are trying to record already exists in the current job as an SS, SO, or CP record. An existing SS, SO, or CP record can be overwritten by measured data. To ... Press ... return to the PT input screen [ESC] or the Abrt softkey record RAW data and update XYZ data the XYZ softkey record RAW data only the RAW softkey No Open Job 100.21 No job is open. To ... Press ... open the job list, if there are existing jobs [1] or select Select job create a new job [2] or select Create job return to the previous screen [ESC] NO Stn Setup 100.22 There is no station record in the current job, or a station setup or BS check has not been done since the program was rebooted. To ... Press ... continue recording [1] or select Continue. If there is already an ST record in the job, the message CO, Use current orientation appears. go to the Stn Setup menu [2] or select STN Setup return to the previous screen [ESC] Total Station Nivo Series Instruction Manual 173 10 Error Messages OVER RANGE 100.23 You are trying to record a coordinate with more than 13 digits Press any key to return to the previous screen. Then check the current ST coordinate. Searching PT Not Found 100.24 There is no point that matches the criteria you entered. Press any key to return to the point input screen. This message may appear in any function where the PT/CD is input, such as Station Setup or Stakeout. Settings Job Settings will be changed 100.25 You have changed one or more of the following job settings: • VA zero or HA in the Angle screen (see Angle, page 108) • Scale, T-P, Sea Lvl, or C&R in the Distance screen (see Distance, page 109) • Coord or Az Zero in the Coordinates screen (see Coordinate, page 110) • Angle, Dist, Temp, or Press in the Unit screen (see Unit, page 111) To ... Press ... discard the changes to the job settings [ESC] or the Abrt softkey. The current job remains open. close the current job and save the changes to the job settings [ENT] or the OK softkey Note – To record a point using the new settings, create a new job using the new settings. Stakeout Input Error 100.26 The point name style used in the Fr field is not the same as the style used in the To field. For example, the Fr field style is 1, and the To field style is A200. Press any key to return to the Fr/To input screen. Then re-enter the point name, using the same naming style in both fields. 174 Total Station Nivo Series Instruction Manual Error Messages NO Stn Setup 10 100.27 You did not perform a station setup or BS check before entering the Stakeout function. To... Press ... go to the Stn Setup menu [2] or select Stn Setup return to the Basic Measurement Screen (BMS) [ESC] go to the Stakeout menu [1] or select Continue Tip – Selecting Continue does not resume the last ST record. You should only use the Continue option if you are sure that the previous ST coordinates and the current HA orientation are correct. Otherwise, records in the Stakeout function may not be correct. Station Setup Calc ST Failed Need additional PT 100.28 Calculating ST failed in resection. This message may appear after you have deleted a point the View shots screen. Press any key to return to the PT input screen. Take another shot to calculate the ST coordinate. Same Coordinate 100.29 The input PT or coordinate is identical to the current station in STN/1:Known, or the same coordinate or point name/number is found in Resection. Press any key to return to the PT input screen. Then use a different PT. Space LOW 100.30 There is not enough space to record a station when you start any of the Station Setup functions. To ... Press ... return to the BMS press [ESC] or the Abrt softkey. Use the DEL softkey in Job Manager to delete old jobs. continue press [ENT] or the OK softkey. You may not be able to record the whole process. XY-coordinate is required 100.31 The input point for ST/BS does not have N/E coordinates. Press any key to return to the PT input screen. Then use a PT that has N/E coordinates. Total Station Nivo Series Instruction Manual 175 10 Error Messages Z-coordinate is required 100.32 The input point for Benchmark does not have a Z coordinate. Press any key to return to the PT input screen. Then use a PT that has a Z coordinate. System Error =SYSTEM ERROR= 100.33 The system has detected an internal error that is related to the lower-level system. Press any key to turn the instrument off. The system will reboot when this error is reported. If you still have more points to shoot in the site, turn the instrument on and repeat the open a job and station setup procedures. Data stored before this error will be kept safely in the Job file. If the error appears frequently, please contact your dealer or Trimble Support and report the message that appears below the =SYSTEM ERROR= line. 176 Total Station Nivo Series Instruction Manual NORTH AMERICA (Survey) Tripod Data Systems P O Box 947 Corvallis, OR 97339 USA +1-541-753-9322 Phone +1-541-757-7439 Fax www.tdsway.com OR NORTH AMERICA (CI/Construction) Trimble Construction Instruments Division/Trimble Geomatics and Engineering Division 5475 Kellenburger Road Dayton, Ohio 45424-1099 USA 800-538-7800 (Toll Free) +1-937-245-5154 Phone +1-937-233-9441 Fax www.trimble.com © xxxx–xxxx, Trimble Navigation LImited. All rights reserved. Trimble is a trademark of Trimble Navigation Limited registered in the United States Patent and Trademark Office and other countries. Nikon is a registered trademark of Nikon. All other trademarks are the property of their respective owners. PN xxxxxxx-xxx (xx/xx)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2009:03:31 08:50:46-07:00 Modify Date : 2009:03:31 08:50:46-07:00 Page Count : 87 Creation Date : 2009:03:31 15:50:46Z Mod Date : 2009:03:31 15:50:46Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : ltsai Metadata Date : 2009:03:31 15:50:46Z Creator : ltsai Title : User Manual - Nivo manual 3.pdfEXIF Metadata provided by EXIF.tools