NIKON TRIMBLE NT0001 Bluetooth module User Manual Nivo manual 2
NIKON-TRIMBLE CO., LTD. Bluetooth module Nivo manual 2
Contents
Host 2 user manual 2 of 3
CHAPTER Preparation In this chapter: Unpacking and Packing the Instrument Charging the Battery Pack Detaching and Re-Attaching the Battery Pack Setting Up the Tripod Centering Leveling Sighting Setting the Measurement Mode and Preparing the Target Measurement in Reflectorless mode Preparing the Reflector Sheet Setting Up the Prism Reflector Total Station Nivo Series Instruction Manual 2 Preparation Unpacking and Packing the Instrument Note – Handle the Nivo series instrument gently to protect it from shocks and excessive vibration. Unpacking To unpack the instrument, grip the carrying handle and gently remove the instrument from the carrying case. Packing To pack the instrument back into the carrying case, please refer to the figure on the right. Charging the Battery Pack Before charging the battery pack, read the warnings (also listed in the Safety section at the front of this manual) and the following notes. WARNING – Do not damage the rechargeable Lithium-ion battery. A damaged battery can cause an explosion or fire, and can result in personal injury and/or property damage. To prevent injury or damage: – Do not use or charge the battery if it appears to be damaged. Signs of damage include, but are not limited to, discoloration, warping, and leaking battery fluid. – Do not expose the battery to fire, high temperature, or direct sunlight. – Do not immerse the battery in water. – Do not use or store the battery inside a vehicle during hot weather. – Do not drop or puncture the battery. – Do not open the battery or short-circuit its contacts. WARNING – Avoid contact with the rechargeable Lithium-ion battery if it appears to be leaking. Battery fluid is corrosive, and contact with it can result in personal injury and/or property damage. To prevent injury or damage: – If the battery leaks, avoid contact with the battery fluid. – If battery fluid gets into your eyes, immediately rinse your eyes with clean water and seek medical attention. Do not rub your eyes! – If battery fluid gets onto your skin or clothing, immediately use clean water to wash off the battery fluid. Total Station Nivo Series Instruction Manual Preparation WARNING – Charge and use the rechargeable Lithium-ion battery only in strict accordance with the instructions. Charging or using the battery in unauthorized equipment can cause an explosion or fire, and can result in personal injury and/or equipment damage. To prevent injury or damage: – Do not charge or use the battery if it appears to be damaged or leaking. – Charge the Lithium-ion battery only in a product that is specified to charge it. Be sure to follow all instructions that are provided with the battery charger. – Discontinue charging a battery that gives off extreme heat or a burning odor. – Use the battery only in equipment that is specified to use it. – Use the battery only for its intended use and according to the instructions in the product documentation. WARNING – To charge the battery pack, use only the battery charger and AC adapter that are supplied with the instrument. Do NOT use any other charger or you may cause the battery pack to catch fire or rupture. The enclosed battery pack cannot be used with other chargers. WARNING – Do not cover the battery charger and AC adapter while the battery pack is being recharged. The charger must be able to dissipate heat adequately. Coverings such as blankets or clothing can cause the charger to overheat. WARNING – Avoid recharging the battery pack in humid or dusty places, in direct sunlight, or near heat sources. Do not recharge the battery pack when it is wet. If you do, you may receive electric shocks or burns, or the battery pack may overheat or catch fire. WARNING – Although the battery pack has an auto-reset circuit breaker, you should take care not to short circuit the contacts. Short circuits can cause the battery pack to catch fire or burn you. WARNING – Never burn or heat the battery. Doing so may cause the battery to leak or rupture. A leaking or ruptured battery can cause serious injury. WARNING – Before storing the battery pack or battery charger, cover the contact points with insulation tape. If you do not cover the contact points, the battery pack or charger may short circuit, causing fire, burns, or damage to the instrument. WARNING – The battery is not itself waterproof. Do not get the battery wet when it is removed from the instrument. If water seeps into the battery, it may cause a fire or burns. Total Station Nivo Series Instruction Manual 2 Preparation Power jack Charge indicator 0 This will read 5V, 4A Calibration indicator 0 Case “Top” edge Calibration button Calibration indicator 1 Charge indicator 1 Battery Slot Battery Slot Applying Power • Plug in the charger to the supplied AC adapter to turn the unit on. The power input must be 5 V with at least 4 A of current capability. Each battery may take up to 2 A while charging. Charging a battery 10 • Simply slide a battery into either battery slot to begin charging. The adjacent charge indicator will illuminate yellow when charging is in progress. The charge indicator will change to green when charging is complete. • Charger slots are completely independent so a battery may be inserted regardless of the state of the other battery slot. • Charging may take 2-4 hours if the battery was normally discharged. • Charging may take up to 5 hours with a completely drained battery which has been stored for several months without use. Total Station Nivo Series Instruction Manual Preparation Conditioning / calibrating a battery • Battery calibration is necessary about once every 6 months or more often if desired. Calibration insures the reported battery charge remaining is accurate. • Hold down the calibration button on the unit and then insert a battery while holding the calibration button to begin a battery calibration. Only the battery which was inserted while the button was depressed will begin calibration. During a battery calibration the battery will be charged, discharged completely, and then recharged before finishing. Calibration should complete in roughly 17 hours and the charger vents should not be covered during a calibration cycle. • The blue calibration indicator light(s) will blink slowly (on 1.5 sec, off 2 sec) while a calibration is in progress and the charge light(s) may be on or off during the calibration cycle. • When a calibration cycle is completed, the calibration light will stop blinking remain on until the corresponding battery is removed. • If the case temperature begins to get too warm while discharging a battery, the calibration light blink will blink on for 0.5 sec then off for 3 seconds and the battery load will be cut in half to prevent further overheating. Battery calibration will take longer to finish if this occurs. When the case temperature drops to a safer level battery discharging will return to normal. • If the case temperature continues to get too hot internally, blinking will become more rapid and eventually the calibration will be aborted. If an abort occurs, the calibration light(s) will blink rapidly and battery charging will be reenabled. Total Station Nivo Series Instruction Manual 11 2 Preparation Detaching and Re-Attaching the Battery Pack Detaching the battery pack CAUTION – Avoid touching the contacts on the battery pack. 1. If the instrument is turned on, press [PWR] to turn it off. 2. Turn the battery box release knob counterclockwise, open the battery box cover and remove the battery pack from the battery box. Inserting the battery pack Before inserting the battery pack, clear any dust or other foreign particles from the battery contacts. 12 1. Turn the battery box release knob counterclockwise and open the battery box cover. 2. Put the battery pack into the battery box. Insert the battery pack with the connectors bottom first, facing inside. 3. Close the battery box cover and turn the knob clockwise until the secure click sound is heard. CAUTION – If the battery box cover is not closed, this could adversely affect the watertightness of the instrument. Total Station Nivo Series Instruction Manual Preparation Setting Up the Tripod CAUTION – The tops of the tripod ferrules are very sharp. When handling or carrying the tripod, take care to avoid injuring yourself on the ferrules. 1. Open the tripod legs enough to for the instrument to be stable. 2. Locate the tripod directly over the station point. To check the tripod’s position, look through the center hole in the tripod head. 3. Firmly press the tripod ferrules into the ground. 4. Level the top surface of the tripod head. 5. Securely fasten the thumb screws on the tripod legs. 6. Place the instrument on the tripod head. 7. Insert the tripod mounting screw into the center hole of the base plate of the instrument. 8. Tighten the tripod mounting screw. Note – Do not carry the instrument while it is attached to a tripod. Centering When you center the instrument, you align its central axis precisely over the station point. To center the instrument, you can either use the optical plummet or a plumb bob. Centering using the optical plummet Note – If you require high accuracy, check and adjust the optical plummet before you center the instrument. For detailed instructions, see Checking and Adjusting the Optical/Laser Plummet, page 136. To center the instrument using the optical plummet: 1. Set up the instrument on the tripod. For detailed instructions, see Setting Up the Tripod, page 13. 2. While looking through the optical plummet, align the reticle with the station point. To do this, turn the leveling screws until the center mark of the reticle is directly over the image of the station point. 3. While supporting the tripod head with one hand, loosen the tripod leg clamps and adjust the lengths of the legs until the air bubble is in the center of the circular level. 4. Tighten the tripod leg clamps. Total Station Nivo Series Instruction Manual 13 2 Preparation 5. Use the electronic level to level the instrument. For detailed instructions, see Leveling, page 15. 6. Look through the optical plummet to check that the image of the station point is still in the center of the reticle mark. 7. If the station point is off center, do one of the following: – If the station point is slightly off center, loosen the tripod mounting screw and then center the instrument on the tripod. Use only direct movement to center the instrument. Do not rotate it. When the instrument is centered, tighten the mounting screw. – If the displacement of the station point is major, repeat this procedure from Step 2. Centering using the laser plummet Note – Do NOT look into the laser directly. Note – If you require high accuracy, check and adjust the laser plummet before you center the instrument. For detailed instructions, see Checking and Adjusting the Optical/Laser Plummet, page 136. 14 1. Set up the instrument on the tripod. For detailed instructions, see Setting Up the Tripod, page 13. 2. Turn on the laser plummet. See Laser plummet ON/OFF, page 36. 3. Align the laser pointer to the station point. To do this, turn the leveling screws until the laser pointer is over the station point. 4. While supporting the tripod head with one hand, loosen the tripod leg clamps and adjust the lengths or the legs until the air bubble is the center of the circular level. 5. Tighten the tripod leg clamps. 6. Use the electronic level to level the instrument. For detailed instructions, see Leveling, page 15. 7. Check the laser pointer is over the station point. 8. If the station point is off center, do one of the following: – If the station point is slightly off center, loosen the tripod mounting screw and then center the instrument on the tripod. Use only direct movement to center the instrument. Do not rotate it. – When the instrument is centered, tighten the mounting screw. – If the displacement of the station point is major, repeat this procedure from Step 2 Total Station Nivo Series Instruction Manual Preparation Centering using a plumb bob 1. Set up the instrument on the tripod. For detailed instructions, see Setting Up the Tripod, page 13. 2. Hang the plumb line on the hook of the tripod mounting screw. 3. Adjust the length of the plumb line so that the tip of the plumb bob is at the height of the station point. 4. Loosen the tripod mounting screw slightly. 5. Using both hands to support the outer side of the tribrach, carefully slide the instrument about on the tripod head until the tip of the plumb bob is positioned over the exact center of the station point. Note – To confirm that the instrument is precisely aligned, check its position from two directions at right angles to each other. Leveling When you level the instrument, you make the vertical axis of the instrument exactly vertical. To level the instrument, use the electronic level. In the leveling work, always set the instrument in face 1 direction (please refer to the Fig.1.1 in page 3). To level the instrument: 1. Move the bubble into the circle drawn on the circular level and then turn on the power. 2. Rotate the alidade until the bottom edge of the keyboard panel is parallel to the two of the leveling screws (B and C). 3. Use leveling screws B and C to move the bubble into the center of the electronic level. 4. Rotate the alidade approximately 90°. 5. Use leveling screw A to move the bubble into the center of the electronic level. 6. Repeat Step 1 through Step 5 to center the bubble in both positions. 7. Rotate the alidade 180°. 8. If the bubble in the electronic level remains centered, the instrument is level. If the bubble moves off center, adjust the electronic level. For detailed instructions, see Adjusting the Electronic Level, page 136. Bottom edge of the keyboard panel Bottom edge of the keyboard panel Total Station Nivo Series Instruction Manual 15 2 Preparation Sighting When you sight the instrument, you aim the telescope at the target, bring the target image into focus, and align the image with the center crosshairs of the reticle. Center crosshairs To sight the instrument: 1. Adjust the diopter: a. Aim the telescope at a blank area, such as the sky or a piece of paper. WARNING – Never look at the sun through the telescope. If you do, you may damage or lose your eyesight. b. 2. Looking through the eyepiece, rotate the diopter ring until the reticle crosshairs are in sharp focus. Eliminate parallax: a. Aim the telescope at the target image. b. Rotate the focusing ring until the target image is in sharp focus on the reticle crosshairs. c. Move your eye vertically and laterally to check whether the target image moves relative to the reticle crosshairs. Diopter ring Telescope focusing ring If the target image does not move, there is no parallax. d. 3. Rotate the tangent screw: – 16 If the target image does move, rotate the telescope focusing ring. Then repeat from Step c. The final turn of the tangent screw should be in a clockwise directions, to align the target accurately on the center crosshairs. Total Station Nivo Series Instruction Manual Preparation Setting the Measurement Mode and Preparing the Target The Nivo series has two measurement modes: Prism mode (Prism) and Reflectorless mode (N-Prism). These modes can be changed at any time by holding down the [MSR1] or [MSR2] key for one second. For more information, see Measurement settings, page 48. To set the measurement mode depending on the target you want to measure, see the following table. Target Target setting Prism, reflector sheet Prism (Prism mode) Other (reflective materials) N-Prism (Reflectorless mode) In some cases, you can measure another target that is not appropriate to the set measurement mode. Note – The Nivo series is Laser Class 1 in the measurement function, and Laser Class 2 in the Laser pointer function. Don’t sight the Prism when the Laser Pointer is on. Measurement with a prism Do not use a prism with scratches, a dirty surface, or a chipped center. Prisms with thin edges are recommended. ✕ ✓ thin edges ✕ chipped center thick edges As the Nivo series is extremely sensitive, multiple reflections on the prism surface can sometimes cause a significant loss in accuracy. To maintain the accuracy of your measurements: Total Station Nivo Series Instruction Manual 17 2 Preparation • When measuring a short distance, incline the prism slightly so that the EDM can ignore unnecessary reflections on the prism surface, as shown below. Hold the prism securely in place and do not move while taking measurements. In Prism mode, in order to avoid false measurements on objects other than the prism or reflector-sheet, targets that are less reflective than the prism or reflector sheet are not measured. Even if you start a measurement, measured values are not displayed. To measure less reflective objects, use the N-prism (reflectorless) mode Measurement in Reflectorless mode The intensity of the reflection from the target determines the distance the Nivo series can measure in this mode. The color and condition of the target surface also affect the measurable distance, even if the targeted objects are the same. Some less-reflective targets may not be measured. The following table describes some examples of targets and approximate measureable distances. Target You can measure approximately... Traffic signs, reflectors 500 meters (1640 feet) Paper (white), veneer (new) 300 meters (990 feet) wall (brightly painted), brick 100 to 200 meters (330 to 660 feet) Measurable distances may be shorter or measurement intervals may be longer in the following cases: • the angle of the laser against the target is small • the surface of the target is wet In direct sunlight, the measurable distance may be shorter. In this case, try to throw a shadow on the target. Targets with completely flat surfaces, such as mirrors, cannot be measured unless the beam and the target are perpendicular to each other. Make sure there are no obstacles between the instrument and the target when taking measurents. When you need to take measurements across a road or a place where vehicles or other objects are frequently moving, take several measurements to a target for the best result. 18 Total Station Nivo Series Instruction Manual Preparation Preparing the Reflector Sheet The reflector sheet can be used for measurements in Prism mode. Assemble the reflector sheet as shown below. Reflector sheet Mini prism adapter Telescopic prism pole Prism pole tripod type PPS Total Station Nivo Series Instruction Manual 19 2 Preparation Setting Up the Prism Reflector 1. Assemble the prism reflector as shown below. Target plate for single prism Target pole Height adjustment adapter is not used. Tribrach adapter 15 Prism C Tribrach W30/W30b Tiltable single prism holder Triple prism holder Tripod 2. Adjust the height of the tribrach adaptor (see page 21). 3. If necessary, change the direction of the prism (see page 21). 4. Set the prism constant (see page 21). 5. If you are using a single prism holder, set the position of the target plate (see page 22). Detailed instructions for Step 2 through Step 5 are provided on the following pages. Note – Nivo series must be used with the Tribrach W30 or W30b. 20 Total Station Nivo Series Instruction Manual Preparation Adjusting the height of the tribrach adapter The tribrach adapter has a height adjustment adapter. To use the prism reflector with a Nivo series instrument, remove the height adjustment adapter as shown in the Figure below. The height adjustment adapter will be used with other Nikon Total Stations. Height adjustment adapter Height adjustment adapter clamp screw Changing the direction of the prism The prism mounted on the tribrach adapter can be rotated to face in any direction. To change the direction of the prism: 1. Release the rotation clamp. To do this, turn the clamp lever counterclockwise. 2. Turn the upper plate of the tribrach adapter until the prism is facing in the required direction. 3. Fasten the rotation clamp. To do this, turn the clamp lever clockwise. Clamp Clamp lever Unclamp Setting the prism constant 1. Attach the prism to the single prism holder or triple prism holder. Tip – To use a triple prism holder as a single prism holder, attach the prism to the center thread of the prism holder. 2. Set the prism constant. To do this, hold down [MSR1] or [MSR2] for one second. For more information, see Measurement settings, page 48. Note – The prism constant of a Nikon prism is always 0, whether it is attached to a single prism holder or a triple prism holder. If your prism constant is not 0 mm, then directly enter the prism constant value in the Const field. For example, if your prism constant is 30 mm, enter 30mm in the Const field on the instrument. Tip – When you use the prism at a short distance, set the prism at a slight angle to the sighting axis, rather than completely square. Total Station Nivo Series Instruction Manual 21 2 Preparation Setting the position of the target plate If using a single prism, make sure that the target plate is aligned with the tribrach adapter and the prism. To set the position of the target plate: 22 1. Use the two set screws supplied to attach the target plate to the single prism holder. 2. Move the target plate within the screw holes until the apex of the wedge pattern is aligned with the vertical axis of the prism and the tribrach adapter. Total Station Nivo Series Instruction Manual Center on axis CHAPTER Getting Started In this chapter: Turning the Instrument On and Off Changing Regional Configuration Pre-sets Display and Key Functions List Display Inputting Data Jobs Measuring Distances Total Station Nivo Series Instruction Manual 23 3 Getting Started Turning the Instrument On and Off Turning on the instrument 1. To turn on the instrument, press [PWR]. The startup screen appears. It shows the model name, current temperature, pressure, date, and time. The display automatically changes to the electronic level after 2 seconds. If you have entered your name or your company’s name in the Owner’s detail field, the text from this field appears on the start-up screen. To set the Owner’s detail field, go to MENU > Settings > Others. For more information, see page 113. Turning off the instrument To enter the power-off process, press [PWR] and [ENT]. Then do one of the following: Press ... To ... [ENT] again turn off the instrument the Reset softkey reboot the program and re-start the instrument the Sleep softkey put the instrument into power-saving mode [ESC] cancel the power-off process and return to the previous screen If you press the Reset softkey, the software is rebooted and the Basic Measurement Screen (BMS) appears without an open job. Sleep mode If you press the Sleep softkey in the Press [ENT] → OFF screen, or enable the Power Save setting (see Power saving, page 110), the instrument goes into sleep mode. When the instrument is in sleep mode, it wakes up if any of the following occurs: 24 • You press a key • The instrument receives a remote control command Total Station Nivo Series Instruction Manual Getting Started • You rotate the alidade • You tilt the telescope Changing Regional Configuration Pre-sets To provide easier configuration for common regional settings, you can quickly configure the Nikon total station to a pre-set combination of default regional settings. The Regional Configuration screen appears only after the language configuration is complete, the instrument has rebooted. 1. Follow the steps in Language, page 113. Once the instrument rebooted, the Regional Configuration screen appears. 2. Press [^] or [v] to highlight the required regional settings and then press [ENT]. 3. If you do not want to change the current settings, press [ESC] and quit. The instrument will continue to use the last configured settings that were configured. The settings affected by the Regional Configuration screen are: Category Setting Europe International United States Angle VA zero Zenith Zenith Zenith Resolution 1"(See note) 1"(See note) 1"(See note) Distance Coordinates Power Save Communication HA Azimuth Azimuth Azimuth Scale 1.000000 1.000000 1.000000 T-P corr. On On On Sea Level Off Off Off C&R corr. 0.132 0.132 0.132 Order ENZ ENZ NEZ Label ENZ ENZ NEZ AZ zero North North North Main Unit Off Off Off EDM Unit Off Off Off Sleep 5 minutes 5 minutes 5 minutes Ext. Comm Nikon Nikon Nikon Baud 4800 4800 4800 Length Parity None None None Stop bit Stakeout Add PT 1000 1000 1000 Units Angle GON DEG DEG Distance meters meters US-ft Total Station Nivo Series Instruction Manual 25 3 Getting Started Category Rec Others Setting Europe International United States Temp °C °C °F Press mm Hg mm Hg In Hg Store DB RAW&XYZ RAW&XYZ RAW&XYZ Data Rec Internal Internal Internal XYZ disp Fast Fast Fast 2nd Unit None None None Split ST No No No CD InputOwner’s Detail Blank Blank Blank The default regional configuration pre-set is “United States” settings. For more information, see Settings, page 108. Display and Key Functions The following figure shows the keys on the Nivo series instrument keyboard and the LCD display. The functions of the Nivo keys are as follows. Key Function Details Turns the instrument on or off. page 24 (Illumination key) page 30 Provides access to the switch window. Turns on/off the LCD backlight if held down for one second. 26 Displays the MENU screen. page 91 Changes the key input mode between alphanumeric and numeric if pressed when you are in a PT or CD field. Activates Qcode mode if pressed when you are In the Basic Measurement Screen (BMS). page 32 Total Station Nivo Series Instruction Manual Getting Started Key Function Details page 81 Records measured data, moves on to the next screen, or confirms and accepts the entered data in input mode. You have the option to record the measurement as a CP record instead of an SS record, if you hold this key down for one second in the Basic Measurement Screen (BMS). The instrument outputs the current measurement data (PT, HA, VA, and SD) on the COM port if you press this key in the BMS or in a Stakeout observation screen. (The Data Rec settings must be set to COM.) Returns to the previous screen. In numeric or alphanumeric mode, deletes input. Starts distance measurement, using the measure mode page 47 settings for the [MSR1] key. Displays measurement mode settings, if held down for one second. page 47 Starts distance measurement, using the measure mode settings for the [MSR2] key. Displays measurement mode settings, if held down for one second. Moves to the next available display screen. Changes the fields that appear on the DSP1, DSP2, and DSP3 screens, if held down for one second. page 49 Displays the Angle menu. page 52 Displays the Station Setup menu. In numeric mode, enters 7. In alphanumeric mode, enters 7. page 53 Displays the Stakeout menu. Shows stakeout settings, if held down for one second. In numeric mode, enters 8. In alphanumeric mode, enters A, B, C, or 8. page 64 Displays the Offset Point Measurement menu. In numeric mode, enters 9. In alphanumeric mode, enters D, E, F, or 9. page 83 Displays the Programs menu, which contains additional measuring programs. In numeric mode, enters 4. In alphanumeric mode, enters G, H, I, or 4. page 71 In numeric mode, enters 5. In alphanumeric mode, enters J, K, L, or 5. Displays RAW, XYZ, or STN data, depending on your setting. In numeric mode, enters 6. In alphanumeric mode, enters M, N, O, or 6. page 38 Total Station Nivo Series Instruction Manual 27 3 Getting Started Key Function Details Executes the function that is assigned to the [USR1] key. In numeric mode, enters 1. In alphanumeric mode, enters P, Q, R, S, or 1. Executes the function that is assigned to the [USR2] key. In numeric mode, enters 2. In alphanumeric mode, enters T, U, V, or 2. page 37 Opens a window where you can enter a code. The default code value is the last code entered. In numeric mode, enters 3. In alphanumeric mode, enters W, X, Y, Z, or 3. page 33 Displays the (HOT) menu, which includes Height of Target, page 34 Temp-Press, Target, Note recording, and Default PT settings. In numeric mode, enters – (minus). In alphanumeric mode, enters . (period), – (minus), or + (plus). page 36 Displays the Bubble indicator. In numeric mode, enters 0. In alphanumeric mode, enters *, /, =, (a space), or 0. Status bar The status bar appears on the right side of every screen. It contains icons that indicate the status of various system functions. Status bar Input mode indicator The Input mode indicator only appears when you are entering points or coordinates. It shows the data input mode: Input mode is numeric. Press a key on the number pad to enter the number printed on the key. Input mode is alphabetic. Press a key on the number pad to enter the first letter printed beside the key. Press the key repeatedly to cycle through all the letters assigned to that key. For example, to enter the letter O in alphabetic mode, press [5] three times. Laser pointer indicator The icon appears while turning on the laser pointer. When the icon is displayed on the screen, the emitting power is laser class 2. Laser pointer ON. (None) 28 Laser pointer OFF. Total Station Nivo Series Instruction Manual Getting Started EDM measurement status When you are taking measurements, the EDM measurement status shows the mode that is being used. When you display observation data, the EDM measurement status shows the mode that was used when the data was collected. Reflectorless mode Communication port status (This is only available when the optional Bluetooth is installed. See Optional Bluetooth function, page 129.) Bluetooth enabled Battery indicator Shows each voltage level of the right and left internal batteries individually. When the external battery is connected with the instrument, its voltage is shown. Internal batteries (above: Left battery, below: Right battery) External battery Internal battery External battery Battery level indication : Battery low If the battery level becomes critically low, the message on the right appears: Total Station Nivo Series Instruction Manual 29 3 Getting Started LCD backlight, Laser pointer, Beep sound and Contrast adjustment [ENT] / [4] [ESC] To turn on/off the 1. LCD backlight, 2. laser pointer or 3. beep sound, and to do the 4. contrast adjustment, press the illumination key and open the switch set up window shown above. Holding down the illumination key for one second also turns on/off the LCD backlight. • To turn on/off each function, press [ENT] when the option 1, 2, 3 or 4 is selected or directly press [1], [2], [3] or [4] numeric key. • Press [^] or [v] to move the cursor up and down. • In the contrast adjustment window, use [^] or [v] to adjust the contrast. To close the window, press [ESC]. 1. LCD backlight LCD backlight is OFF LCD backlight is ON 2. Laser pointer Laser pointer is OFF Laser pointer is ON 3. Sound Sound is OFF Sound is ON 30 Total Station Nivo Series Instruction Manual Getting Started [DSP] key Use the key to change the current display screen or to change display settings. Switching between display screens When several display screens are available, the DSP indicator appears at the top left of the screen, and the screen indicator (for example, 1/4) appears at the top right. To move to the next available screen, press [DSP]. For example, if the DSP2 screen is currently displayed, press [DSP] to move to the DSP3 screen. The screen indicator changes from 2/4 to 3/4. When the secondary distance unit is set, an additional screen is available. It shows the HD, VD, and SD values. For information on setting the secondary distance unit, see page 112. The smallest unit of display for distances measured in feet-and-inches is 1/16 in. Smaller units are impractical in the field. When the actual value is greater than 99999'11''15/16, the “>” symbol is shown. If the actual distance is less than -9999'11''15/16, the “`” (solid triangle) symbol is shown. This does not affect calculations. The precise value is used internally in all cases. Customizing items in the Basic Measurement Screen (BMS) To customize the items that are displayed on the DSP1, DSP2, and DSP3 screens: 1. Hold down [DSP] for one second. 2. Use the arrow keys [^], [v], [<], and [>] to highlight the item that you want to change. 3. Use the and softkeys to scroll through the list of items that can be displayed for this item. The items that you can choose from are HA, AZ, HL, VA, V%, SD, VD, HD, Z, and (none). Total Station Nivo Series Instruction Manual 31 3 Getting Started 4. To save your changes, press the Save softkey. Alternatively, highlight the last item for DSP3 and press [ENT]. The DSP screens show the items you have selected. Except for the (none) item, you cannot display the same item on more than one line of the same screen. The items displayed in the DSP1, DSP2, DSP3, and DSP4 screens are also used in the corresponding Stakeout screens (SO2, SO3, SO4, and SO5). You can also customize the displayed items in Stakeout. Header characters The following header characters can be used in DSP screens: • A colon (:) indicates that tilt correction is applied to the value. • A hash symbol (#) indicates that tilt correction is off. • An underscore (_) under the tilt correction character indicates that Sea Level Correction or Scale factor is applied. [MODE] key Use the [MODE] key to change the keyboard mode for the current screen. Changing input mode while entering points or codes When the cursor is in a point (PT) or code (CD) field, press [MODE] to change the input mode between alphanumeric (A) and numeric (1). The input mode indicator in the status bar changes to show the current input mode. When the cursor is in a height (HT) field, only numeric input mode is available. Pressing [MODE] has no effect when the cursor is in a HT field. 32 Total Station Nivo Series Instruction Manual Getting Started Quick code measurement mode 1. To activate Quick code measurement mode, press [MODE] in the BMS. The PT field shows the default point name. 2. Press any numeric key ([0] through [9]) to start measuring and recording points. A list of the numeric keys and their assigned feature codes appears on the right side of the screen. For example, when you press [6], the code assigned to 6 is selected, and the instrument starts a measurement. 3. If you have set the record mode to Confirm (see Measurement settings, page 48), the Record PT screen appears after each measurement. Do one of the following: – To record the point, press [ENT]. – To return to the BMS, press [ESC]. To assign a new feature code to a numeric key, press [^] or [v] to highlight the code that you want to change. Then press the Edit softkey. You can use the DSP softkey to change the values shown in the measurement box, in the same way as you use the [DSP] key in the Basic Measurement Screen (BMS). 4. To return to the BMS from the Qcode screen, press [MODE] or [ESC]. [COD] key In the BMS, press [COD] to change the default feature code that will appear in the CD field when you record a point. Setting the default code When you press [COD] in the BMS, a window for entering the feature code appears. You can use the List and Stack softkeys to enter the code. Total Station Nivo Series Instruction Manual 33 3 Getting Started Qcode observations To enter the Quick code observation routine, press the Qcode softkey. In this function, you can use the ten numeric keys to both select a feature code and shoot a point. To change the measurement mode for the Quick code observation, press the Sett softkey. In Quick code measurement, the Rec mode can only be set to Confirm or ALL. [HOT] key The HOT key menu is available on any observation screen. To display the HOT key menu, press [HOT]. Changing the height of the target To change the height of the target, press [HOT] to display the HOT menu. Then either press [1] or select HT and press [ENT]. Enter the height of the target, or press the Stack softkey to display the HT stack. The HT stack stores the last 20 HT values entered. Setting the temperature and pressure To set the current temperature and pressure, press [HOT] to display the HOT menu. Then either press [2] or select Temp-Press and press [ENT]. Enter the ambient temperature and pressure. The ppm value is updated automatically. 34 Total Station Nivo Series Instruction Manual Getting Started Selecting the target set A target set specifies settings for the target type, the prism constant, and height of target. When you change the selected target set, all three settings are changed. You can use this function to quickly switch between two types of target, such as a reflector sheet and a prism. You can prepare up to five target sets. Press [HOT] to display the HOT menu. Then either press [3], or select Target and press [ENT]. A list of the five target sets appears. To select a target set, either press the corresponding numeric key ([1] through [5]), or use [^] or [v] to highlight the target set in the list and press [ENT]. To change the settings defined in a target set, highlight the target set in the list. Then press the Edit softkey. Type Const HT Prism/N-Prism –999 to 999 mm –9.990 to 99.990 m HT can be left blank in the target set. If you leave it blank, the current HT value is always applied to the measurement. When a target set is selected, the Type and Const values are copied to both [MSR1] and [MSR2] settings, and to the measurements in Qcode. If you have specified a value for HT, this value is also copied to the current HT. Entering a field note To enter a field note, press [HOT] to display the HOT menu. Then either press [4], or select Note and press [ENT]. This function can be used at any time on any observation screen. Each note can be up to 50 characters. The note is stored as a CO record in the raw data. To display a list of previously used notes, press the Stack softkey. The stack stores the last 20 notes. Use [^] or [v] to highlight [ENT] to select the note. a note in the list. Then press Total Station Nivo Series Instruction Manual 35 3 Getting Started Setting the default point name To change the default point name, press [HOT] to display the HOT menu. Then press [5], or select Default PT and press [ENT]. This function is available from any observation screen. Modify the default point name for the next record. Press [ENT] to confirm the new default point name. The new point name is appears as the default PT name on the input screen. Bubble indicator The bubble indicator is automatically displayed if the instrument goes out of level while the compensators are turned on, and also appears after the start up screen. To display the bubble indicator in an observation screen, press The Nivo series has two-axis level compensation. To turn the leveling compensators on or off, press [<] or [>]. When the leveling compensators are turned off, the text OFF appears on the screen. If the instrument is more than ±3'30" out of level, the text OVER appears on the screen. To return to the observation screen, press [ESC] or [ENT]. Laser plummet Laser plummet ON/OFF Press [ ON] to enable the laser plummet. Press [ESC] to close the bubble indicator window. Press [ OFF] to disable the laser plummet. Press [Lumi.] to open the luminance adjustment window. Press [ESC] to disable the laser plummet and close the bubble indicator window. 36 Total Station Nivo Series Instruction Manual (Laser plummet is on.) Getting Started Laser luminance adjustment Laser luminance can be set to 4 levels. Press [Max.] to increase the luminance of the laser plummet. Press [Min.] to decrease the luminance of the laser plummet. Press[ESC] / [ENT] to return to the bubble indicator window. The current setting of leveling compensators is indicated by header characters (:, #, :, and #) after field labels (such as HA, VA, SD, and HD) in observation screens. For more information, see Header characters, page 32. [USR] keys If you use a function frequently in the field, you can assign it to the [USR1] or [USR2] key. Whenever you press a [USR] key, the function that is assigned to that key is activated directly. The following functions can be assigned to the [USR] keys: • Input HT • BS Check • Base XYZ • Default PT • Select Target • Input Temp-Press • Input Note • The following menus, or a single function from one of these menus: – Cogo – O/S – PRG By default, Input HT is assigned to [USR1], and no function is assigned to [USR2]. Hold down the [USR] key for one second to display the list of functions that can be assigned to the key. The currently assigned function is indicated by an asterisk (*) beside the function name. To change the function that assigned to the key, press [^] or [v] to highlight the function. Then press [ENT]. Total Station Nivo Series Instruction Manual 37 3 Getting Started If an item on the list has an arrow (->) beside it, this item is a menu. If you highlight a menu item and then press [ENT], a sub-menu appears. The first item on the sub-menu ends with the text [MENU]. If you select this item, the whole menu is assigned to the [USR] key. To assign a specific function from the sub-menu, press [^] or [v] to highlight the function. Then press [ENT]. Once you have assigned a function to a [USR] key, it is called directly whenever you press that [USR] key in the BMS. To change the type of data that is assigned to the [USR] keys in MENU > 1sec-Keys > [USR]. For more information, see [USR] key settings, page 132. [DAT] key Use the [DAT] key to quickly access data in the current job from observation screens. When you press [DAT] in the BMS or in observation screens in functions such as Stakeout, 2Pt RefLine, and Arc RefLine, the assigned data in the current job appears. Hold down [DAT] for one second in the BMS or an observation screen to display the Select Format screen. Use this screen to change the type of data that is assigned to [DAT]. Press [1] or select DAT [MENU] to display the Data menu whenever you press [DAT]. 38 Total Station Nivo Series Instruction Manual Getting Started When you select an option from this screen, the change is applied immediately, and the selected data type appears. Press [ESC] to return to the previous observation screen. To change the type of data that is assigned to [DAT], go to MENU > 1sec-Keys > [DAT]. For more information, see [DAT] key settings, page 133. List Display Available jobs or data appear in a list display when you do any of the following: • view or edit data (MENU > Data) • open the code list, point list, or Job Manager (MENU > Job) • search for points or codes In the list, the current cursor position is shown in reverse video (it appears as white text on a black background). Press [^] or [v] move the cursor one line up or down. If the Page Up icon appears, there are more pages before the current page. Press [<] to move up one page. If the Page Down icon appears, there are more pages after the current page. Press [>] to move down one page. To select an item from the list, move the cursor onto the item and press [ENT]. Inputting Data Entering a point name or number You can use numeric or alphanumeric names up to 16 characters long to identify points. The default name for a new point is the last point name entered, with the last digit incremented. For example, if the last point name was A100, the default name for the next point is A101. Total Station Nivo Series Instruction Manual 39 3 Getting Started If the last character of the previous point name is alphabetic, the default point name is the last point name. When the cursor is in a PT (point) field, there are several ways to specify a point, or input coordinates. Entering an existing point When you enter a known point name or number, the coordinates of that point are displayed briefly. A short beep sounds before the next screen appears or the next field is selected. To adjust the duration of the coordinate window display, go to MENU > Settings > Others. To leave the window open until you press [ENT], set the XYZ disp field to +ENT. For more information, see page 112. Entering a new point When you input a new point name or number, a coordinate input screen appears. Enter the point’s coordinates in NE, NEZ, or elevation-only (Z) format. Press [ENT] on the last line (the CD field) to store the point in the current job. Pressing [ENT] without a point name To use a point without recording the coordinates, press [ENT] in a PT field, without entering a point name. 40 Total Station Nivo Series Instruction Manual Getting Started The input coordinates are used in the calculation. They are not saved in the database. Specifying a wildcard (*) If you include an asterisk (*) when you enter a point or code name, a list of points that match the entered text appears. Use [^] or [v] to move the cursor to the point that you want to use. Then press [ENT]. If the Page Up or Page Down icons are displayed, use [<] or [>] to page up or page down the list. When you select a point from the list, its coordinates are displayed and a beep sounds. Recording an instant measurement You can also input a point by recording an instant measurement. To do this, press the MSR softkey. An observation screen appears. Press [MSR1] or [MSR2] to start a measurement. To change the height of the target, press the HT softkey. To go to the point recording screen when you have finished the measurement, press [ENT]. Enter the point or code name. Press [ENT]. Total Station Nivo Series Instruction Manual 41 3 Getting Started When you move the cursor to a field, the current or default value appears in inverted text (this is the default “Replace All” input mode). Press [>] to change the input mode to Overwrite mode and highlight the first character. Press [<] to move the cursor the end of the string. Entering a point from the stack The point stack is a list of recently used points. To display the stack, press the Stack softkey when the cursor is in the PT field. Use [^] or [v] to move the cursor to the point that you want to use. Then press [ENT]. When you return to the point input screen, the selected point name is entered in the PT field, incremented by one. For example, if you selected the A101 point, A102 appears in the PT field. The stack shows the last 20 point names used, in chronological order from last used to first used. Entering a point from the point list To display a list of existing points, press the List softkey when the cursor is in the PT field. Use [^] or [v] to move the cursor to the point that you want to use. Then press [ENT]. When you return to the point input screen, the selected point name is entered in the PT field. You can add digits or alphabetic characters if required. 42 Total Station Nivo Series Instruction Manual Getting Started Entering a code The CD (Code) field always defaults to the last code used. You can change the selected code on the input point screen, or you can press [COD] in the BMS. For more information, see [COD] key, page 33. You can use numeric or alphanumeric names up to 16 characters long to identify codes. Entering a code directly To enter a code directly, press [MODE] to change the input mode to alphanumeric or numeric mode. Then use the keypad to enter the code. Entering a code from the stack The code stack is a list of recently used codes. The stack may contain up to 20 codes. To display the stack, press the Stack softkey when the cursor is in the CD field. Use [^] or [v] to move the cursor to the code that you want to use. Then press [ENT]. The selected code is copied to the CD field. When the instrument is rebooted, the code stack is cleared. Entering a code from the code list To display a list of existing codes, press the List softkey when the cursor is in the CD field. To edit the code list, go to MENU > Data > Code List. For more information, see Editing an item in the point list or code list, page 126. Use [^] or [v] to highlight the feature code that you want to use. Then press [ENT]. Total Station Nivo Series Instruction Manual 43 3 Getting Started A layer has an arrow at the end of the code label. If you highlight a layer in the list and then press [ENT], the codes and layers in that layer are displayed. When you return to the input screen, the selected code is entered in the CD field. Items are shown in alphabetic order. You can also use the first character search to quickly find a code. For more information, see Advanced feature: Searching for a code by using the first character, page 44. Advanced feature: Searching for a code by using the first character To find a code quickly when the code list appears, use the first-character search. For example, to see feature codes that begin with T, use the keypad to enter the letter T. To do this, press [1] twice. After each press of the key, the input mode field displays the selected letter. For example, if you press [1], S appears. If you quickly press [1] again, T appears. If you do not press the [1] key again, the letter T is selected. Once you have selected a letter, the cursor moves to the feature code beginning with that letter. If there is no code beginning with that letter, the cursor moves to the next available letter. Qcodes Quick codes (Qcodes) let you shoot and record many points with feature codes in the field. You can register up to ten Quick codes. To register Qcodes, press the Edit softkey. For more information, see Quick code measurement mode, page 33. Press [MODE] to switch Qcodes on or off. Press the Edit softkey to change the Qcode. You can edit the entire code, or just the number at the end of the code. You can still use [DSP] to change the background displays. 44 Total Station Nivo Series Instruction Manual Getting Started Entering values in feet and inches When either US Survey Feet (US-Ft) or International Feet (I-Ft) is selected as the distance unit, you can enter and display distances, HIs, HTs, and coordinate values either in decimal feet, or in feet and inches For more information, see Unit, page 111, and Others settings, page 112. To enter values in feet and inches in an input screen, enter the elements, separated by periods (.), in the following format: [.] [.] [.] [ENT] (0–11) (0–15) (0–99) The default denominator is 16. If the denominator is 16, you do not have to enter it, and it is not displayed on the screen. For example, if you enter [2] [.] [0] [8] [.] [5] [.] [ENT], it appears as 2'08" 5/ (2 feet, 8 and 5/16ths inches). The following examples show how various values are entered: To enter ... Type ... 65' 5 3/8" [6] [5] [.] [5] [.] [3] [.] [8] [ENT] 65' [6] [5] [ENT] 65' 5" [6] [5] [.] [5] [ENT] 65' 5 3/8" [6] [5] [.] [5] [.] [6] [ENT] 5 3/8" [0] [.] [5] [.] [3] [.] [8] [ENT] or [0] [.] [5] [.] [6] [ENT] The numerator and denominator that you enter are automatically converted to the closest value from the following list: 0, 1/8, 1/4, 3/8, 1/2, 5/8, 3/4, 7/8, 1/16, 3/16, 5/16, 7/16, 9/16, 11/16, 13/16, 15/16. If the denominator is 16, it is not shown on the screen. Jobs To record data on the instrument, you must create or open a job. Tip – Before you use the instrument for the first time, check the job settings. Total Station Nivo Series Instruction Manual 45 3 Getting Started Creating a new job 1. Press [MENU] to open the MENU screen. 2. Press [1] to open the Job Manager. 3. Press the Creat softkey to open the Create Job screen. 4. Enter the job name. 5. Press the Sett softkey to check the job settings. You cannot change a job’s settings once you have created the job. 6. Press [ENT] in the last field of the Job Sett screen to create the new job. If either of the messages MAX 32JOBs or Data Full appears, delete at least one existing job to free space. You cannot free space by deleting records in an existing job. Creating a control job A control job, or common file, stores coordinate data that is used by several field jobs. You can create a control job in the office. 1. Press [MENU] to open the MENU screen. 2. Press [1] or select Job to open the Job Manager. 3. Move the cursor to the job that you want to use as the control job. 4. Press the Ctrl softkey. 5. Press the Yes softkey. For more information, see Creating a control job, page 46. When you enter a point name or number, the system searches in the current job first. If the point is not found in the current job, the search is automatically extended to the control job. If the point is found in the control job, the selected point is copied to the current job as a UP record. 46 Total Station Nivo Series Instruction Manual Getting Started Measuring Distances Sighting a prism reflector WARNING – Never look at the sun through the telescope. If you do, you may damage or lose your eyesight. WARNING – Precautions should be taken to ensure that persons do not look directly, with or without an optical instrument, into the beam. WARNING – Laser beam path should be located well above or below eye level wherever practicable. For information on how to assemble the prism reflector, see Setting Up the Prism Reflector, page 20. Sight the telescope to see crosshairs at the center of the prism reflector. Sighting a single prism Sighting a tiltable single prism Measuring distances To take a distance measurement, press [MSR1] or [MSR2] in the Basic Measurement Screen (BMS) or in any observation screen. While the instrument is taking a measurement, the prism constant appears in a small font. Total Station Nivo Series Instruction Manual 47 3 Getting Started If the average count is set to 0, measurements are taken continuously until you press [MSR1], [MSR2], or [ESC]. Each time a measurement is taken, the distance is updated. If the average count is set to a value from 1 to 99, the averaged distance appears after the last shot. The field name SD changes to SDx to indicate the averaged data. To change the height of target (HT), temperature, or pressure, press [HOT]. For more information, see [HOT] key, page 34. Settings that relate to corrections (T-P corr, Sea Level, C&R corr., and Map projection) are included in the job settings. These settings are job-specific. If you need to change any of these settings, you must create a new job. For more information, see Job settings, page 93, and Settings, page 108. Measurement settings To view the measurement settings,hold down [MSR1] or [MSR2] for one second. Use [^] or [v] to move the cursor between the fields. Use [<] or [>] to change the value in the selected field. Field Values Target • • Prism N-prism Const (prism constant) –999 mm through 999 mm Mode • • AVE (Average count) 0 (Continuous) through 99 Rec mode One of the following: • MSR only • Confirm • ALL Precise Normal Target field If the measurement is started with the Target field set to Prism, there is a dash “–” in front of the prism constant. If the measurement is started with the Target field set to N-prism, there is a square bracket “]” in front of the prism constant. 48 Total Station Nivo Series Instruction Manual Getting Started The symbol then constantly runs from left to right over the prism constant in the display. When an N-prism measurement is taken, the icon appears in the status bar (above the battery icon). Incorrect Target settings may result in measurements outside the precision and intervals specified for the instrument. If a prism target is aimed in the N-prism mode, the warning message "Signal High! → Try Prism Mode" will be displayed because of the excessive light reflection. A measurement made immediately after changing the target setting may take a longer time than usual.The Target setting is used to apply better cyclic-error adjustment in distance measurement. It efficiently eliminates multipath reflection. Rec mode field The Rec mode setting controls how the [MSR1] and [MSR2] keys operate in the BMS. The MSR only setting is the default measurement mode. After a measurement, the instrument stops in the BMS and waits for you to press [ENT] before recording the point. The Confirm setting displays the Record PT screen before data is recorded. The ALL setting is a quick shooting and recording mode. The instrument automatically records the point using the default PT/CD. The instrument then returns to the BMS for the next measurement. Total Station Nivo Series Instruction Manual 49 3 50 Getting Started Total Station Nivo Series Instruction Manual CHAPTER Applications In this chapter: HA Reset and Angle Operations Station Setup Stakeout Program Key Recording Measurement Data Measuring Offsets Total Station Nivo Series Instruction Manual 51 4 Applications HA Reset and Angle Operations To open the Angle menu, press [ANG] in the BMS. To select a command from this menu, either press the corresponding number key, or press [<] or [>] to highlight the command and then press [ENT]. Setting the horizontal angle to 0 To reset the horizontal angle to 0, press [1] or select 0-Set in the Angle menu. The display returns to the Basic Measurement Screen (BMS). Entering the horizontal angle To display the HA Input screen, press [2] or select Input in the Angle menu. Use the numeric keys to enter the horizontal angle. Then press [ENT]. To enter 123°45'50", type [1] [2] [3] [.] [4] [5] [5] [0]. The displayed value is rounded to the minimum angle increment. Recording a foresight point after repeat angle measurement 1. To activate repeat angle measurement, press [3] or select Rept. in the Angle menu. HR=0 appears. 2. Sight the backsight and press [ENT]. 3. Sight the foresight and press [ENT]. The horizontal angle is accumulated and the value is held again. 52 4. To end repeat angle measurement, press [ESC]. 5. When you have accumulated enough horizontal angle between the backsight and the foresight, press [MSR1] or [MSR2] to take a measurement to the foresight. Total Station Nivo Series Instruction Manual Applications The averaged horizontal angle appears. This value is fixed until the process is finished or cancelled. HRx = HR¦ ÷ N HA = BSAz + HRx (normalized) HRx is not updated even if the instrument is moved. 6. Press [ENT] to store the foresight as a CP record. Check the PT, HT, and CD values. Then press [ENT] to record. In repeat angle measurement, the HA is replaced by HR¦. The number of repeat angles appears at the top of the screen (for example, N= 5). Horizontal angles can be measured up to 1999°59'59". This function stores both raw and XYZ data as CP records, regardless of the Store DB setting. Horizontal angle hold To hold the horizontal angle to the current value, press [5] or select Hold in the Angle menu. To set the horizontal angle to the displayed value, press softkey. [ENT] or the Set To cancel the process and return to the Basic Measurement Screen (BMS), press [ESC] or the Abrt softkey. Station Setup To open the Stn Setup menu, press [STN] in the BMS. To select a command from this menu, press the corresponding number key. Alternatively, press [<] or [>] to highlight the command and then press [ENT]. Press [^] or [v] to move up or down one page. The last function used is highlighted. Total Station Nivo Series Instruction Manual 53 4 Applications Setting up a station with known coordinates or azimuth 1. Press [1] or select Known in the Stn Setup menu. 2. Enter a point name or number in the ST field. 3. – If the input point number or name is an existing point, its coordinates are displayed and the cursor moves to the HI (Height of instrument) field. – If the point is new, a coordinate input screen appears. Enter the coordinates for the point. Press [ENT] after each field. When you press [ENT] in the CD field, the new point is stored. – If the specified point has a code, the code appears in the CD field. Enter the instrument height in the HI field and then press [ENT]. The Backsight screen appears. 4. 54 Select an input method for defining the backsight point. – To sight the backsight by entering coordinates, see below. – To sight the backsight by entering the azimuth and angle, see page 56. Total Station Nivo Series Instruction Manual Applications Sighting the backsight by entering coordinates Xb X0 Instrument height Backsight point (Xb, Yb, Zb) Station point (Xi, Yi, Zi) Y0 Yb 1. To enter coordinates for the backsight point (BS), press [1] or select Coord in the Backsight screen. 2. Enter the point name. If the point exists in the job, its coordinates are shown. 3. If you intend to take a distance measurement to the BS, enter the height of target in the HT field. 4. Sight the BS. Press [ENT] to complete the setup. – AZ To record a full shot (with HA, VA, and SD values) to the BS, press [MSR1] or [MSR2]. Azimuth calculated by coordinates – If you are measuring to a known coordinate BS, press [DSP] to display a QA screen. The QA screen shows the dHD and dVD values, which indicate the difference between the measured distance and the distance calculated from the known coordinates. 5. To record the station, press [ENT]. 6. To finish the station setup after taking a distance measurement, press [ENT]. ST and F1 records are stored to the current job. Total Station Nivo Series Instruction Manual 55 4 Applications Sighting the backsight by entering the azimuth angle X0 Instrument height Backsight point Azimuth Station point (Xi, Yi, Zi) Y0 1. To enter the azimuth angle to the backsight point, press [2] or select Angle in the Backsight screen. 2. If there is no point name for the BS, press [ENT] on the BS field. 3. In the AZ field, enter the azimuth angle to the BS point. If you press [ENT] without entering a value in the AZ field, the azimuth is automatically set to 0°00'00". 4. 56 Sight the BS point and press [ENT]. ST and F1 records are stored in the job. Total Station Nivo Series Instruction Manual Applications Setting up a station using multiple point resection A resection sets up the station using angle/distance measurements to known points. X0 Y1 Height 2 Known point 1 (X1, Y1, Z1) Instrument height X1 X2 Height 1 Y0 Known point 2 (X2, Y2, Z2) Station point (Xi, Yi, Zi) Y2 You can use a maximum of 10 points in a resection. Measurements can be distance and angle, or angle only. Calculation starts automatically when enough measurements are taken. You can delete poor observations and recalculate if necessary. You can also select the BS point. If the angle between known point 1 and known point 2 (measured from the station point) is extremely acute or extremely oblique, the resulting solution will be less reliable geometrically. For geometric reliability, select known point locations (or station point locations) that are widely spaced. 1. To start the resection, press [2] or select the Stn Setup menu. Resection in 2. Enter the point name for the first observation point (PT1). 3. Enter the target height and press [ENT]. Total Station Nivo Series Instruction Manual 57 4 Applications 4. Sight PT1 and press [MSR1] or [MSR2]. 5. To proceed to the next point, press [ENT]. 6. Enter the second point (PT2) and its height of target. 7. Measure to PT2 and press [ENT]. When the instrument has enough data, it calculates the station (STN) coordinates. – If more than the minimum required data is available, a standard deviation screen appears. – To take measurements to strengthen geometry of the resection, press the Add softkey. For information about the View softkey, see Advanced feature: Viewing and deleting a measurement in resection, page 59. 8. When the results are satisfactory, record the station. To do this, press [ENT] or the REC softkey. 9. Enter the height of instrument, if required. Press [ENT]. The ST field defaults to the last recorded PT + 1. 10. To change the station name, move to the ST field and edit or replace the text. If you have set Split ST to Yes, the ST field defaults to the last recorded ST value + 1. For more information, see Others settings, page 112. 58 Total Station Nivo Series Instruction Manual Applications BS defaults to the first observed point. 11. To change the BS, press the Change softkey. 12. Select the BS point that you want to use and press [ENT]. 13. To finish the resection setup, move the cursor to the BS field and press [ENT]. The minimum data required for a resection is either three angle shots, or one angle shot and one distance shot. If you use a distance shot, the distance between the target points must be greater than the measured distance. Stn-Z is calculated from distance-measured data. If no distances are measured, then Stn-Z is calculated using angle-only measurements to points with 3D coordinates. Advanced feature: Viewing and deleting a measurement in resection To check the measurements to each known point, press the View softkey on the calculated STN (sigma or coordinate) screen. dHA dVD dHD Distributed HA errors in each direction VD errors between measured distance and calculated distance HD errors between measured distance and calculated distance To delete a measurement (because of large sigma values, for example), highlight the measurement data or display the detail screen for the measurement. Then press the DEL softkey. The STN coordinates are automatically recalculated. To continue resection observations, press the Add softkey. The input screen for the next PT appears. Total Station Nivo Series Instruction Manual 59 4 Applications Setting up the station quickly without coordinates The station point (ST) in this function defaults to a new point number. For the new point, MP (0, 0, 0) is stored as the coordinates. When the ST is manually changed to a known point name, the station is set up on the coordinates of the known point. 1. ST HI BS AZ To enter Quick Station setup, press [3] or select Quick in the Stn Setup menu. Station point (defaults to the last recorded PT + 1, or ST + 1, depending on the Split ST setting) Height of instrument Backsight point (blank) Backsight azimuth (defaults to zero) 2. No default PT is assigned to the BS. Leave this field blank, or enter a BS point name. 3. The backsight azimuth (AZ) defaults to zero, but you can change this. 4. To complete the station setup, sight the BS and press [ENT]. When you press [ENT] in the AZ field, both HA and AZ are reset to the value you have entered. Even if both ST and BS are known points, this function does not calculate the backsight angle (AZ) automatically. To calculate the AZ between two known points (ST and BS), use Station Setup > Known. For more information, see Setting up a station with known coordinates or azimuth, page 54. Determining station elevation 60 1. Press [4] or select Remote BM in the Stn Setup menu. 2. Enter the BM point and press [ENT]. When the point is found, it appears briefly. The cursor then moves to the HT field. 3. Enter the HT and press [ENT]. Total Station Nivo Series Instruction Manual Applications 4. Sight the BM point and press [MSR1] or [MSR2]. The updated station coordinates are displayed. You can change the HI in this screen. 5. To record the updated STN, press [ENT]. When the HI is changed, the Z coordinate is updated before the station is recorded. You must complete a station setup before you use the Remote Benchmark function. Checking and resetting the backsight direction You must complete a station setup before you use the BS check function. This function always refers to the backsight point from the last ST record stored in the current open job. 1. To enter the backsight (BS) check function, press [5] or select BS Check in the Stn Setup menu. HA BS 2. Current HA reading The HA to the BS in the last station setup. Enter station coordinates for observations without recording data. Do one of the following: – To reset the horizontal angle to the HA set in the last station setup sight the BS and press the Reset softkey or press [ENT]. – To cancel the process and return to the BMS, press the Abrt softkey or press [ESC]. Total Station Nivo Series Instruction Manual 61 4 Applications Base XYZ function: Base XYZ does not store a ST record, so the BS Check cannot check the backsight when you enter a station using Base XYZ. To store raw data, use one of the other functions in the Stn Setup menu. This function does not store an ST record in the job. You can use this function without an open job. If there is an open job when you use this function, a CO record is stored to indicate that the instrument’s base coordinates have changed. 1. To enter the Base XYZ function, press [6] or select Base XYZ in the Stn Setup menu. The current instrument XYZ values are shown as the default. 2. Enter the new instrument XYZ values and press [ENT]. 3. Do one of the following: – To reset the horizontal angle, enter a value in the HA field and press [ENT]. – If you do not need to reset the HA, leave the HA field blank and press [ENT]. The display returns to the BMS. Two-point resection along a known line 1. To enter the Known Line function, press [7] or select Known Line in the Stn Setup menu. 2. Enter a known point as P1. If you enter a new point name, a coordinate input screen appears. Sight P1 and press [MSR1] or [MSR2] to take a measurement. Press [ENT]. 62 Total Station Nivo Series Instruction Manual Applications 3. 4. Choose how you want to define a known line: – To define the line by entering P2 coordinates, press [1] or select By Coord. – To define the line by entering the azimuth, press [2] or select By Angle. If you select By Angle, the azimuth input screen appears. Enter the angle value and press [ENT]. A measurement screen appears. 5. Sight P2 and press [MSR1] or [MSR2] to take a measurement. Press [ENT]. After the measurement to P2 is completed, the coordinates of the station are calculated. 6. To record the station, press [ENT] or the REC softkey. 7. To check your measurement, press the DSP softkey. If you defined the line by entering its azimuth, HD and VD between P1 and P2 are displayed. If you defined the line by entering the P2 coordinates, the difference of HD (dHD) and VD (dZ) between your measurement data and input coordinate data are displayed. 8. Enter the station name, the height of instrument (HI), and a feature code (CD) if required. The station name defaults to the last recorded PT + 1, or last recorded ST + 1, depending on the Split ST setting. 9. Backsight (BS) defaults to the first point (P1). To change it, highlight the BS field and then press the Change softkey. 10. To finish the setup and record the station, press [ENT] in the BS field. Total Station Nivo Series Instruction Manual 63 4 Applications Sample records CO, Temperature:20C Pressure:1013hPa Prism:0 … ST,9005, ,265, ,1.2350,150.40300,150.40300 F1,265,1.6040,79.0010,90.30150,89.35260, F1,200,1.4590,50.2300,269.4035,93.50110, CO, P1-P2 HD=122.0350 VD=0.5600 Stakeout FiLL OUT CUT IN IN OUT Height of target FILL CUT To display the Stakeout menu, press [S-O]. 64 Total Station Nivo Series Instruction Manual Applications Specifying the stakeout point by angle and distance 1. To display the input screen for the distance and angle to the target, press [1] or select HA-HD in the Stakeout menu. 2. Enter the values and press [ENT]. HD dVD HA Horizontal distance from station point to stakeout point Vertical distance from station point to stakeout point Horizontal angle to stakeout point If you press [ENT] without entering HA, the current HA is used. 3. Rotate the instrument until the dHA is close to 0°00'00". 4. Sight the target and press [MSR1] or [MSR2]. When the measurement is completed, the differences between the target position and the stakeout point are displayed. dHA R/L IN/OUT CUT/FILL Difference in horizontal angle to the target point Right/Left (Lateral error) In/Out (Longitudinal error) Cut/FilL Once a measurement is taken, the Cut/Fill value and Z coordinate are updated as the VA is changed. If you press [HOT] in any observation screen, the HOT key menu appears. You can use this menu at any time to change HT and T-P. Total Station Nivo Series Instruction Manual 65 4 Applications Using [DSP] to switch between display screens Press [DSP] to switch between the Stakeout display screens. The following screens are available: S-O1 S-O2 S-O3 S-O4 dHA← R← OUT↑ CUT↑ HA VA SD HA VD HD HL V% HD S-O5 S-O6 S-O7 S-O8 dX dY dZ rSD rVD rHD HD VD SD The S-O8 screen is only available if the secondary distance unit is set. For more information, see Others settings, page 112. Every time you press [DSP], the next screen appears. If you press [DSP] in the last screen (S-O7, or S-O8 if the secondary distance unit is set), the S-O1 screen appears. To customize the S-O2, S-O3, and S-O4 screens, hold down [DSP] for one second. For more information, see Customizing items in the Basic Measurement Screen (BMS), page 31. To record the stakeout point, press [ENT]. PT defaults to the last recorded PT+1. Press [ENT] to record the point. After recording the point, it returns to the observation screen. You can continue observation, or press [ESC] to input another angle and distance for stakeout. Specifying the stakeout point by coordinates 1. To start a stakeout by coordinates, press [2] or select XYZ in the Stakeout menu. 2. Enter the point name that you want to stake and press [ENT]. You can also specify the point by code or radius from the instrument. 66 Total Station Nivo Series Instruction Manual Applications If several points are found, they are displayed in a list. Use [^] or [v] to move up and down the list. Use [<] or [>] to move up or down one page. 3. Highlight a point in the list and press [ENT]. The delta angle and the distance to the target are shown. 4. Rotate the instrument until the dHA is close to 0°00'00". Press [MSR1] or [MSR2]. dHA HD 5. Difference in horizontal angle to the target point Distance to the target point Ask the rodman to adjust the target position. When the target is on the intended position, the displayed errors become 0.000 m (or 0.000 ft). dHA R/L IN/OUT CUT/FILL Difference in horizontal angle to the target point Right/Left (Lateral error) In/Out (Longitudinal error) Cut/FilL To switch between display screens, press [DSP]. This function works as in the angle-distance stakeout, except that the screen counter (for example, S-O1/8) is not displayed. For more information, see Using [DSP] to switch between display screens, page 66. Once a measurement is taken, the Cut/Fill value and Z coordinate are updated as the VA is changed. 6. To record the point, press [ENT]. PT defaults to the specified PT + 1000. Use the Add Constant field in MENU > Settings > Stakeout to specify an integer that is added to the point number being staked to generate a new number for recording the staked point. The default value is 1000. For example, when you stake out PT3 with an Add Constant of 1000, the default number for SO record is 1003. For more information, see Stakeout, page 111. After recording the point, the display returns to the observation screen. When you press [ESC], the display returns to the PT/CD/R input screen. If you entered the stakeout point using a single point name, the PT defaults to the last PT + 1. Total Station Nivo Series Instruction Manual 67 4 Applications If you selected a point from the list, the display returns to the list, unless all points have been selected. Press [ESC] to return to the point input screen. Advanced feature: Specifying a stakeout list by range input 1. To input points by range, press the Fr/To softkey in the PT field. 2. Enter the start point (Fr) and the end point (To). The range between Fr and To must be less than 1001 points. If existing points are found between Fr and To, a point list appears. To highlight a point, press [^] or [v]. To go to the stakeout observation screen, press [ENT]. If you have assigned a control job, and additional points are found in the control job, the Ctrl softkey appears under the list. DivLine S-O This function divides the line between the instrument and the first target by an input span number. It then guides you to stake out the points, one by one. 68 1. Press [3] or select DivLine S-O in the Stakeout menu. 2. Set up the baseline. To do this, sight the target on the line (the end point) and press [MSR1] or [MSR2]. Total Station Nivo Series Instruction Manual Applications 3. Enter the total stake number in the Span total field. The observation screen for the first stake (from the instrument) appears. 4. Sight the prism and press [MSR1] or [MSR2]. 5. Use [^] or [v] to change the guide point. You can calculate and guide up to double the number of the stakes. 6. To record the point as an SO record, press [ENT]. For example, if you measure to the end point at 100 m from the instrument and set the span total to 2, the following four points are calculated and can be staked: HD <1/2> <2/2> <3/2> <4/2> 50 m 100 m 150 m 200 m RefLine S-O This function allows you to stake out a point based on the Sta, O/S, and dZ to a specified line. 1. Press [4] or select RefLine S-O in the Stakeout menu. Total Station Nivo Series Instruction Manual 69 4 Applications 2. Enter the first point (P1) of the line. If you press [ENT] without entering a PT name, you can enter temporary coordinates which are not recorded in the job. Alternatively, press the MSR softkey to measure a point. 3. Enter the second point (P2) of the line. 4. Enter offsets to the line. Press [ENT] in a blank field to enter the value 0.0000. Sta O/S (+) (-) dZ Distance from P1 along the line Distance perpendicular to the line Right side of the P1-P2 line Left side of the P1-P2 line Difference in height from the line 5. Rotate the instrument until the dHA is close to 0°00'00". 6. Sight the target and press [MSR1] or [MSR2]. When a distance measurement is taken, the difference from the design point appears. 7. To record the point as an SO record, press [ENT]. Using [DSP] to switch between display screens You can use [DSP] to switch between display screens. This function works as in the angle-distance stakeout. For more information, see Using [DSP] to switch between display screens, page 66. 70 Total Station Nivo Series Instruction Manual Applications Program Key To display the Programs menu, press [PRG]. Measuring distance and offset values along a specified line 1. Press [1] or select 2Pt RefLine in the Programs menu. 2. Enter the first point for the reference line. Alternatively (to enter the point by measuring), press the MsrPT softkey. Direct Measurement screen Press the MsrPT softkey to display a direct measurement screen. Sight the target and press [MSR1] or [MSR2]. The Record PT screen appears. If you press [ESC] in the Record PT screen, the measured point is used but not recorded in the job. 3. Enter the second point for the reference line. 4. Enter an asterisk (*) in the PT field to perform a wildcard search. A list of matching points appears. Highlight a point in the list and then press [ENT]. PT2 Prism dZ Sta Prism PT1 PT2 O/S PT1 Sta Plain view Side view Total Station Nivo Series Instruction Manual 71 4 Applications 5. Sight the prism or reflective sheet and press [MSR1] or [MSR2]. Sta Horizontal distance from P1 to the measure point along the P1-P2 line Horizontal offset from the P1-P2 line to the measured point Vertical offset from the P1-P2 line to the measured poin O/S dZ Using [DSP] to switch between display screens Press [DSP] to switch between the Stakeout display screens. The following screens are available: REF1 REF2 Sta O/S dZ REF3 HA VA SD REF4 HA VD HD REF5 HD VD SD The REF5 screen is only available if the secondary distance unit is set. For more information, see Others settings, page 112. Every time you press [DSP], the next screen appears. If you press [DSP] in the last screen (REF4 or REF5), the REF1 screen appears. To store the point and its offset distance information, press [ENT]. Enter the point name and feature code. You can also use this screen to change the HT value. Sample records CO, 2pt-Ref Pt:16 & Pt:13 Az:311.2932 CO, Sta= -12.6876 Offset= 1.3721 dZ= 0.0971 SS,17,1.0000,6.9202,18.4700,80.3120,15:48:48,2REF-LINE 72 Total Station Nivo Series Instruction Manual Applications Measuring distance and offset values on the arc-curve 1. Press [2] or select Arc RefLine in the Programs menu. 2. Enter the start of the curve point (P1) and the azimuth of its tangent line (AZ1). 3. To enter P1 by direct measurement, press the MSR softkey. 4. Choose a method to define the arc. P2 can be any point on the tangent line that is to exit the curve. 5. In the radius (Rad) field, enter a positive value for a clockwise curve. Enter a negative value for a counterclockwise curve. When all factors have been entered, the instrument calculates the curve. Total Station Nivo Series Instruction Manual 73 4 Applications If the curve length (Len) is too large for a circle of the given radius, it is shortened. To ... Press ... switch between display screens [DSP] change HT [HOT] record points [ENT] Using [DSP] to switch between display screens Press [DSP] to switch between the Stakeout display screens. The following screens are available: ARC1 ARC2 Sta O/S dZ ARC3 HA VA SD ARC4 HA VD HD ARC5 HD VD SD The ARC5 screen is only available if the secondary distance unit is set. For more information, see Others settings, page 112. Every time you press [DSP], the next screen appears. If you press [DSP] in the last screen (ARC4 or ARC5), the ARC1 screen appears. To record the point, press [ENT] on any observation screen. The arc is stored in comment records. Sample records CO,Arc P1:583 AZ1=0.0000 P2:102 CO, AZ2=311.2932 Radius=50.0000 Length=125.6637 CO, Sta= -12.6876 Offset= 1.3721 dZ= 0.0971 SS,17,1.0000,6.9202,18.4700,80.3120,15:48:48,2REF-LINE 74 Total Station Nivo Series Instruction Manual Applications Remote distance measurement This function measures the horizontal distance, vertical distance, and slope distance between two points. 2nd sighting point rSD 1st sighting point rVD rHD Horizontal angle 0 direction 2nd sighting point rHA 1st sighting point Station point rSD rHD rVD rV% rGD rAZ Slope distance between two points Horizontal distance between two points Vertical distance between two points Percentage of grade (rVD/rHD) × 100% Vertical grade (rHD/rVD) :1 Azimuth from first point to second point Measuring between the current and the first point measured 1. To enter the RDM (Radial) function, press [3] or select RDM(Radial) in the Programs menu. 2. Sight the first point and press [MSR1] or [MSR2]. The distance from the station point to the first point appears. Total Station Nivo Series Instruction Manual 75 4 Applications 3. Sight the second point and press [MSR1] or [MSR2]. The distances between the first and second point are displayed. rSD rVD rHD Slope distance between two points Vertical distance between two points Horizontal distance between two points 4. To change display screens, press [DSP]. rAZ rV% rGD Azimuth from first point to second point Percentage of grade (rVD/rHD) × 100% Vertical grade (rHD/rVD) :1 5. To record the distance and angle information as a comment record, press [ENT] in the 1/2 or 2/2 observation screen. Default point numbers are displayed. You can change these point numbers. To record a note, press [ENT] in the To field. Data that you save in RDM functions is stored in RM records. For more information, see RM records, page 116. When you download data in Nikon RAW format, they are output as comment (CO) records. Measuring between the current point and the immediately preceding point 1. To enter the RDM (Continuous) function, press select RDM(Cont.)in the Programs menu. [4] or 2. 76 Follow the procedure as for a radial RDM measurement. For more information, see Measuring between the current and the first point measured, page 75. Total Station Nivo Series Instruction Manual Applications Difference between “1:Cont.” and “2:Radial” P3 P2 P3 P4 P2 P4 P1 P1 1:Cont. (The preceding two points are subject to calculation.) 2:Radial. (Calculations are made with reference to the first point.) Measuring remote elevation A prism is required only at the sighting (target) point Arbitrary point Sighting point Station point 1. To enter the Remote Elevation Measurement function, press [5] or select REM in the Programs menu. 2. Enter the height of target. 3. Sight the target point and press [MSR1] or [MSR2]. Total Station Nivo Series Instruction Manual 77 4 Applications 4. Loosen the vertical clamp, and turn the telescope to aim at an arbitrary point. The difference in elevation (Vh) appears. You can use an REM measurement to update the height of target. Take a measurement to the prism, sight the bottom of the prism pole, and press [ENT]. Measuring distance and offset values on the vertical plane Baseline 1. To enter the 2-Pt Reference Plane function, press [6] or select V-Plane in the Programs menu. 2. Enter two points to define the plane. To enter the point by direct measurement, press the MsrPT softkey. When you press the MSR softkey, a temporary observation screen appears. 78 3. Press [MSR1] or [MSR2]. The Record PT screen appears. 4. Enter a value in the PT and CD fields. Press [ENT]. Total Station Nivo Series Instruction Manual Applications 5. Enter the second point on the vertical plane. Press [ENT]. Once the plane is defined, the calculated Sta and dZ values are updated as you move the telescope. No distance measurement is required. Sta Horizontal distance from P1 to the target point along the baseline Vertical distance from P1 to the target point dZ Using [DSP] to switch between display screens Press [DSP] to switch between the plane display screens. The following screens are available: PLN1 Sta dZ PLN2 PLN3 HA VA Every time you press [DSP], the next screen appears. If you press [DSP] in the last screen (PLN3), the PLN1 screen appears. To record the point, press [ENT] on any screen (VPLN1/3 to V-PLN3/3). Enter PT and CD. Then press [ENT]. Sample records CO,Vertical Ref Plane Pt1:516-A1 Pt2:530 CO,Sta=68.021 dz=17.459 SS,30123-A48,1.5480,16.4020,40.4720,89.0730,14:22:47, Total Station Nivo Series Instruction Manual 79 4 Applications Measuring distance and offset values on the slope Target P2 (X2,Y2,Z2) Stn (X,Y,Z) P3 (X3,Y3,Z3) P1 (X1,Y1,Z1) 1. To enter the 3-Pt Reference Plane function, press [7] or select S-Plane in the Programs menu. 2. Enter three points to define the slope plane. To enter the point by direct measurement, press the MSR softkey. If you press [ENT] in a blank field, an input screen for temporary coordinates appears. These coordinates will not be stored. When you have entered the temporary coordinates, appears instead of the PT name. If the plane is defined by two points (by selecting 2Pt), the vertical plane is the same as the plane used in the V-Pln function, but the indicating factors are Sta and dZ, not a and b. For more information, see Measuring distance and offset values on the vertical plane, page 78. 80 Total Station Nivo Series Instruction Manual Applications Once the plane is defined, the calculated a and b values are updated as you move the telescope. No distance measurement is required. Distance between P1 and the point that is perpendicular to the target point along the P1P2 line Length of the perpendicular line from the target point to the P1-P2 line Using [DSP] to switch between display screens Press [DSP] to switch between the plane display screens. The following screens are available: PLN1 PLN2 PLN3 HA VA Every time you press [DSP], the next screen appears. If you press [DSP] in the last screen (PLN3), the PLN1 screen appears. To record the point, press [ENT] on any screen (S-PLN1/3 to S-PLN3/3). Enter PT and CD. Then press [ENT]. Sample records CO,3ptPlane P1:1062 P2:2902 P3:1547 CO,a=31.497 b=14.239 SS,30123-A49,1.6110,0.0000,234.3210,86.0955,16:07:18, Recording Measurement Data Recording data from any observation screen To record points on observation screens, press [ENT]. PT defaults to the last recorded PT + 1. You can enter the PT name from the point list or the point stack. For more information, see Entering a point from the point list, page 42, and Entering a point from the stack, page 42. You can also use the code list or the code stack. For more information, see Entering a code from the code list, page 43, and Entering a code from the stack, page 43. Total Station Nivo Series Instruction Manual 81 4 Applications To record the point, press [ENT] on the last field. When recording sideshots, stakeout records and control shots from the Rept function, you can choose to store raw data only, XYZ data only, or both. For more information, see Recording, page 112. If HA or VA is moved after you take a measurement but before you press [ENT], the angle recorded is the angle shown when [ENT] is pressed. In an angle-only record, SD is always recorded as 0.0000. If the point name that you want to record already exists in the job, an error message appears. Depending on the type of existing record, you can overwrite the old record with the new data. For more information, see Recording Data, page 173. Hold down [ENT] for one second to record the measurement as a CP record. Outputting data to the COM port If you press [ENT] while the [COM] icon appears in an observation screen, a line of data is output to the COM port. Note – If [COM] appears, data is not stored to the job when you press [ENT]. The format of the output data is defined by the setting of the Ext.Comm field in MENU > Settings > Comm. For more information, see Communications, page 111. To output data on the COM port when you press [ENT], set the Data Rec field in MENU > Settings > Rec to COM. For more information, see Recording, page 112. 82 Total Station Nivo Series Instruction Manual Applications Sample output records through COM port When the Ext.Comm field is set to NIKON: TR PN: PT8 SD:000066626 HA:003856010 VA:008048500 HT:0000061757 (TR PN: point name SD HA VA HT; when ACK is returned, PN is incremented.) When the Ext.Comm field is set to SET: 0006662 0804806 0394324 97 (SD VA HA Chk-SUM) Measuring Offsets Measuring taped offsets 1. To enter the taped offset function, press [1] or select Tape in the Offset menu. If you have not taken a distance measurement before entering this function, a temporary measurement screen appears. 2. Sight the target and press [MSR1] or [MSR2]. 3. Enter offset distances from the measured point. Use [^] or [v] to move to the appropriate offset field. Left (-) Up (+) Out (+) Down (-) In (-) Right (+) Total Station Nivo Series Instruction Manual 83 4 Applications You can enter any combination of taped offset distances to specify the point. 4. To go to the recording PT screen, press [ENT] in the last field. The calculated coordinates are shown. 5. Enter a PT (and CD) value. 6. Press [ENT] to record the point. Raw data is also recalculated, based on the taped offset value. Measuring angle offsets 1. To enter the angle offset function, press [2] or select Angle in the Offset menu. If you have not taken a distance measurement before entering this function, a temporary measurement screen appears. 2. Sight the target and press [MSR1] or [MSR2]. 3. To take the angle offset, rotate the alidade and telescope. The measured distance (HD) remains unchanged. 4. To record the offset point, press [ENT] or the OK softkey. The XYZ data is also recalculated, based on the new angle. You can record an angle offset in the Basic Measurement Screen (BMS). After taking a distance measurement, rotate the alidade and/or telescope. Then press [ENT] to record the measured distance with the updated angle value. If you use this method, the dimension of the angle offset is not stored as a CO record. To store the CO record, use the O/S function. 84 Total Station Nivo Series Instruction Manual Applications Two-prism pole 1. To enter the two-prism pole function, press [3] or select 2Prism Pole in the Offset menu. 2. Sight the first prism and press [MSR1] or [MSR2]. 3. Sight the second prism and press [MSR1] or [MSR2]. 4. Enter the distance between the second prism and the target point. Alternatively, if you do not need QA information, you can leave the distance between the first and the second prism blank. 5. If you do enter a P1-P2 distance, the QA screen appears. Compare the entered value and the measured distance to check the accuracy of the observation. 6. To record the point, press [ENT] or the OK softkey. Sample records SS,14,0.0000,38.9200,271.0350,89.2630,11:04:15,DITCH CO,2Prism O/S: P1-P2= 0.5090( 0.5060) P2-Tgt= 0.5020 Note – In this sample data, 0.5090 is the measured value. 0.5060 is the entered value. Total Station Nivo Series Instruction Manual 85 4 Applications Extending a line by horizontal angle offset 1. To enter the line extension (by HA) function, press [4] or select +Line by HA in the Offset menu. 2. Sight the first prism (or target) and press [MSR1] or [MSR2]. The display moves to the next screen. 3. Sight the second prism (or target) and press [MSR1] or [MSR2]. 4. Sight the alternative place on the same vertical line as the required target point. 5. To calculate the coordinates and the raw data of the target point, press [ENT]. 6. To record the point, enter a PT (and CD) value and press [ENT]. The height of target is fixed to 0.0000 for the offset point. Sample records SS, 40, 0.0000, 48.3304, 169.20370, 82.02470, 10:52:37 CO, PT1, 0.0000, 48.3020,169.19165, 83.58565 CO, PT2, 0.0000, 48.3155,168.54250, 85.42440 CO, O/S MSR:40 0.0000 0.0000 169.20370 87.02340 86 Total Station Nivo Series Instruction Manual Applications The calculated point (TGT) is stored as a SS record. Measurements to the first and second target (P1 and P2) are stored as comment records (PT1 and PT2). The last record records the angle measurement to the ALT (vertically offset point from the actual target point). Entering a horizontal distance after an angle-only shot This function is useful when the instrument is very close to the point and it is difficult to take a measurement using the EDM. 1. To enter the Input HD function, press [5] or select Input HD in the Offset menu. 2. Turn the telescope in the direction of the point that you want to store. 3. Enter the HD. Usually this is the taped distance from the instrument point. 4. Enter a PT (and CD) value and press [ENT]. The target point is calculated and recorded as an SS record. Sample records SS,158,0.0000,77.0518,62.08380,108.06510,11:51:48, CO, Input HD:76.1243 Total Station Nivo Series Instruction Manual 87 4 Applications Calculating a corner point 1. To enter the corner point function, press [6] or select Corner in the Offset menu. 2. Take a distance measurement to the first prism (or target) on the wall. Press [MSR1] or [MSR2]. 3. Sight a second point on the same wall with the first point measurement. Press [MSR1] or [MSR2]. 4. Sight the first point on the second wall. Press [MSR1] or [MSR2]. 5. If the two walls are at right angles, press the softkey to calculate the corner point by three points. Calc 88 6. If you take a measurement to a fourth point, the corner point can be calculated as the intersection of two walls (P1-P2 and P3-P4). The default elevation is given by P4. 7. Enter a PT (and CD) value. The height of target (HT) defaults to the value used in the last measurement. 8. To record the corner point, press [ENT]. Total Station Nivo Series Instruction Manual Applications Sample records SS, 58, 0.0000, 48.3304, 169.19165, 82.02470, 10:52:37, FLOOR2 CO, PT1, 1.0080, 48.3020,169.19165, 83.58565 CO, PT2, 1.0080, 48.3155,128.54250, 85.42440 CO, O/S MSR:40 0.0000 0.0000 169.20370 87.02340 The calculated corner point is stored as an SS record. The next three or four comment records are measured points. For example: CO, Point name (fixed to PT1, PT2 etc.), HT, SD, HA, VA. Measuring circle offsets 1. To enter the circle center calculation function, press [7] or select Circle in the Offset menu. If you have not taken a measurement to the circle before entering this function, a temporary measurement screen appears. 2. Sight any point on the surface of the circle and press [MSR1] or [MSR2]. If you use a prism attached to the surface of the circle for the distance measurement, press the +SD softkey to eliminate the offset error (from the attached point to the measured surface of the prism) before you press [ENT]. 3. Sight one edge of the circle and press [ENT]. If you have taken a distance measurement to the center of the circle, press the Calc softkey to calculate the offset using one edge angle observation. 4. Sight the other edge of the circle and press [ENT]. Total Station Nivo Series Instruction Manual 89 4 Applications The instrument calculates and records the center of the circle. It also calculates the coordinates of the center point and the radius of the circle. 5. To record the point, press [ENT] or the OK softkey. Sample records SS,71,1.5000,37.0518,32.08380,81.06510,11:51:48, CO, PT1, 0.0000, 0.0000,47.05350, 83.58560 CO, PT2, 0.0000, 0.0000, 29.53010, 83.58560 CO,O/S MSR:71 1.5555 36.5418 38.28360 81.06510 CO,Radius of circle 0.356 CO,Input +SD:0.0020 The calculated point (center of the circle) is stored as an SS record. The following one or two comment records are angle-measured points. For example: CO, Point name (fixed to PT1/ PT2), HT(0.0000), SD(0.0000), HA, VA. If you press the +SD softkey before you sight Edge1, the input value is recorded at the end. Extending the slope distance 1. To enter the function for extending the slope distance, press [8] or select Input dSD in the Offset menu. If you have not taken a distance measurement before entering this function, a temporary measurement screen appears. 2. Enter the slope distance that you need to add or subtract. You can enter any value from –99.990 through +99.990 m (–328.000 through +328.000 ft). 3. To record the point, press [ENT]. Sample records SS,83,1.5000,77.0518,62.08380,81.06510,11:51:48, CO,O/S MSR:83 1.5555 76.5518 62.08380 81.06510 90 Total Station Nivo Series Instruction Manual
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2009:03:31 08:49:37-07:00 Modify Date : 2009:03:31 08:49:37-07:00 Page Count : 84 Creation Date : 2009:03:31 15:49:37Z Mod Date : 2009:03:31 15:49:37Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : ltsai Metadata Date : 2009:03:31 15:49:37Z Creator : ltsai Title : User Manual - Nivo manual 2.pdfEXIF Metadata provided by EXIF.tools