VEGA Americas PULS67 VEGA PULS 67 Level Probing Radar User Manual Manual revised 1
VEGA Americas Inc. VEGA PULS 67 Level Probing Radar Manual revised 1
Contents
- 1. Manual revised 1
- 2. Manual revised 2
Manual revised 1
Operating Instructions VEGAPULS 67 4 … 20 mA/HART Radar Content Content About this document 1.1 1.2 1.3 .. .. .. .. .. .. .. .. .. .. .. .. Configuration. . . . . . . . . . . . . . . . Principle of operation . . . . . . . . . . Operation . . . . . . . . . . . . . . . . . . Packaging, transport and storage . .. .. .. .. 10 11 12 12 General instructions. . . . . . . . . . . . . . . . . . . . . 14 Mounting preparation . . . . . . . . . . . . . . . . . . . . 15 Mounting instructions . . . . . . . . . . . . . . . . . . . . 18 Preparing the connection . . . . . . . . . . . Connection steps - Instrument housing . Wiring plan, single chamber housing. . . Wiring plan, double chamber housing . . Wiring plan - version IP 66/IP 68, 1 bar. Switch on phase . . . . . . . . . . . . . . . . . .. .. .. .. .. .. 24 25 26 28 30 30 Short description . . . . . . . . . . . . . . . . . . . . . . . 31 Insert indicating and adjustment module . . . . . . 31 Adjustment system . . . . . . . . . . . . . . . . . . . . . 33 VEGAPULS 67 • 4 … 20 mA/HART 32938-EN-080610 Set up with the indicating and adjustment module PLICSCOM 6.1 6.2 6.3 Connecting to power supply 5.1 5.2 5.3 5.4 5.5 5.6 Mounting 4.1 4.2 4.3 Authorised personnel . . . . . . . . . . . . . . . . Appropriate use. . . . . . . . . . . . . . . . . . . . Warning about misuse . . . . . . . . . . . . . . . General safety instructions . . . . . . . . . . . . Safety approval markings and safety tips . CE conformity . . . . . . . . . . . . . . . . . . . . . Fulfilling of NAMUR recommendations . . . FCC/IC conformity (only for USA/Canada) . Safety instructions for Ex areas . . . . . . . . Manufacturer declaration . . . . . . . . . . . . . Functional range of approved instruments . Environmental instructions . . . . . . . . . . . . Product description 3.1 3.2 3.3 3.4 For your safety 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Target group . . . . . . . . . . . . . . . . . . . . . . . . . . Symbolism used . . . . . . . . . . . . . . . . . . . . . . . Content 6.4 6.5 6.6 Setup with PACTware™ and other adjustment programs 7.1 7.2 7.3 7.4 7.5 Connect the PC via VEGACONNECT 3 . . . . Connect the PC via VEGACONNECT 4 . . . . Parameter adjustment with PACTware™. . . . Parameter adjustment with AMS™ and PDM Saving the parameter adjustment data . . . . . .. .. .. .. .. 44 46 47 48 48 .. .. .. .. 49 49 51 52 Maintenance and fault rectification 8.1 8.2 8.3 8.4 Setup procedure . . . . . . . . . . . . . . . . . . . . . . . 34 Menu schematic . . . . . . . . . . . . . . . . . . . . . . . 41 Saving the parameter adjustment data . . . . . . . 43 Maintenance, cleaning . . . . . . . . . . Remove interferences . . . . . . . . . . Exchanging the electronics module. Instrument repair . . . . . . . . . . . . . . Dismounting 9.1 9.2 Dismounting steps . . . . . . . . . . . . . . . . . . . . . . 53 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 10 Supplement 10.1 10.2 10.3 10.4 Technical data. . . . . . . . Dimensions . . . . . . . . . . Industrial property rights. Trademark . . . . . . . . . . .. .. .. .. 54 61 66 66 Supplementary documentation Information: Supplementary documents appropriate to the ordered version come with the delivery. You can find them listed in chapter "Product description". 32938-EN-080610 Instructions manuals for accessories and replacement parts Tip: To ensure reliable setup and operation of your VEGAPULS 67, we offer accessories and replacement parts. The associated documents are: 27720 - VEGADIS 61 30176 - Electronics module VEGAPULS series 60 VEGAPULS 67 • 4 … 20 mA/HART About this document 1 About this document 1.1 Function This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instructions for maintenance and fault rectification. Please read this information before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device. 1.2 Target group This operating instructions manual is directed to trained personnel. The contents of this manual should be made available to these personnel and put into practice by them. 1.3 Symbolism used Information, tip, note This symbol indicates helpful additional information. Caution: If this warning is ignored, faults or malfunctions can result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result. Ex applications This symbol indicates special instructions for Ex applications. à List The dot set in front indicates a list with no implied sequence. Action This arrow indicates a single action. Sequence Numbers set in front indicate successive steps in a procedure. 32938-EN-080610 VEGAPULS 67 • 4 … 20 mA/HART For your safety 2 For your safety 2.1 Authorised personnel All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with the device the required personal protection equipment must always be worn. 2.2 Appropriate use VEGAPULS 67 is a sensor for continuous level measurement. You can find detailed information on the application range in chapter "Product description". Operational reliability is ensured only if the instrument is properly used according to the specifications in the operating instructions manual as well as possible supplementary instructions. For safety and warranty reasons, any invasive work on the device beyond that described in the operating instructions manual may be carried out only by personnel authorised by the manufacturer. Arbitrary conversions or modifications are explicitly forbidden. 2.3 Warning about misuse Inappropriate or incorrect use of the instrument can give rise to application-specific hazards, e.g. vessel overfill or damage to system components through incorrect mounting or adjustment. 2.4 General safety instructions 32938-EN-080610 This is a high-tech instrument requiring the strict observance of standard regulations and guidelines. The user must take note of the safety instructions in this operating instructions manual, the country-specific installation standards as well as all prevailing safety regulations and accident prevention rules. The emitting frequency of VEGAPULS 67 is in the K band range. The low transmitting power lies far below the internationally permitted limit values. When the instrument used correctly, it presents no danger to human health. It may be operated without restriction outside of closed metallic vessels. VEGAPULS 67 • 4 … 20 mA/HART For your safety The instrument must only be operated in a technically flawless and reliable condition. The operator is responsible for troublefree operation of the instrument. During the entire duration of use, the user is obliged to determine the compliance of the required occupational safety measures with the current valid rules and regulations and also take note of new regulations. 2.5 Safety approval markings and safety tips The safety approval markings and safety tips on the device must be observed. 2.6 CE conformity VEGAPULS 67 is in CE conformity with EMC (89/336/EWG) and LVD (73/23/EWG). Conformity has been judged according to the following standards: EMC: - Emission EN 61326: 1997 (class B) - Susceptibility EN 61326: 1997/A1:1998 R & TTE directive: I-ETS 300-440 Expert Opinion No. 05-111723, Notified Body No. 0700 LVD: EN 61010-1: 2001 2.7 Fulfilling of NAMUR recommendations With respect to interference resistance and emitted interference, the NAMUR recommendation NE 21 is fulfilled. With respect to compatibility, the NAMUR recommendation NE 53 is fulfilled. This applies also to the corresponding indicating and adjustment components. VEGA instruments are generally upward and downward compatible. Sensor software for DTM VEGAPULS 67 HART, PA or FF DTM VEGAPULS 67 for adjustment software PACTware™ Indicating and adjustment module for sensor software The software version of VEGAPULS 67 can be determined as follows: VEGAPULS 67 • 4 … 20 mA/HART 32938-EN-080610 The parameter adjustment of the basic sensor functions is independent of the software version. The range of available functions depends on the respective software version of the individual components. For your safety via PACTware™ on the type label of the electronics via the indicating and adjustment module You can view all software histories on our website www.vega. com. Make use of this advantage and get registered for update information via e-mail. 2.8 FCC/IC conformity (only for USA/Canada) The VEGAPULS 67 must be configured pointing downward The VEGAPULS 67 is limited to use in enclosed metal, inside enclosed metal, concrete, or fibre-reinforced plastic concrete, or fibre-reinforced plastic vessels. vessels only. Any other use is prohibited. Note about this manual: this manual is intended to be used internationally. There are figures and illustrations which depict the use of the device in open air and open-topped tank environments. These types of installations are not in compliance with FCC/IC approvals. This VEGAPULS 67 sensor is FCC/IC approved with all of the antennas described in this operating instructions manual. Modifications or changes to this device not expressly approved by VEGA could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: The device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. 32938-EN-080610 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the users will be required to correct the inference at their own expense. VEGAPULS 67 • 4 … 20 mA/HART For your safety 2.9 Safety instructions for Ex areas Please note the Ex-specific safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Exapproved instruments. 2.10 Manufacturer declaration In conformity with DIN EN 60079-14/2004, para. 5.2.3, point c1, VEGAPULS 67 is suitable for use in zone 2. The operator must use the instrument as it was intended to be used and follow the specifications of the following documents: this operating instructions manual this manufacturer declaration (24626) the applicable installation regulations Max. increase of the surface temperature during operation: 27 K (individual components in the instrument) With an ambient temperature of 70 °C (158 °F) on the housing and a process temperature of 70 °C (158 °F), the max. ambient temperature during operation is 97 °C (207 °F). Measures to maintain explosion protection during operation: VEGAPULS 67 • 4 … 20 mA/HART 32938-EN-080610 Operate the instrument in the range of the specified electrical limit values. Permissible supply voltage: see "Technical data" Mount and operate the instrument in such a way that no danger of ignition from electrostatic charges is to be expected. The antenna, the process fitting or the housing (as the case may be depending on instrument version) are made of electrically non-conductive plastic. Make sure that the seal is mounted correctly between lower part of the housing and cover. Screw the cover on tightly. Make sure there is no explosive atmosphere present if you intend to operate the instrument with opened cover Make sure that the cable gland is tight and strain-relieved. The outer diameter of the connection cable must be adapted to the cable gland. Tighten the pressure screw of the cable gland carefully. Cover unused openings for cable glands tightly Mount the instrument in such a way that the sensor cannot touch the vessel wall or vessel installations. Keep in mind the influence of product movement in the vessel. For your safety The surface temperature of the housing must not exceed the ignition temperature of the surrounding explosive atmosphere This instrument was assessed by a person who fulfils the DIN EN 60079-14 requirements. 2.11 Functional range of approved instruments Instruments with specific approvals are partly supplied with an earlier hardware or software version. For approval-technical reasons, some functions for these instruments will be available only at a later date. You will find corresponding instructions in the description of the individual functions in this operating instructions manual. 2.12 Environmental instructions Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection. The environment management system is certified according to DIN EN ISO 14001. Please help us fulfil this obligation by observing the environmental instructions in this manual: Chapter "Packaging, transport and storage" Chapter "Disposal" 32938-EN-080610 VEGAPULS 67 • 4 … 20 mA/HART Product description 3 Product description 3.1 Configuration Scope of delivery The scope of delivery encompasses: Components VEGAPULS 67 radar sensor Mounting strap (option) Compression or adapter flange (optional) Documentation - this operating instructions manual - Operating instructions manual - 27835 "Indicating and adjustment module PLICSCOM" (optional) - Supplementary instructions manual - 31708 "Heating for indicating and adjustment module" (optional) - Supplementary instructions manual "Plug connector for continuously measuring sensors" (optional) - Ex-specific "Safety instructions" (with Ex-versions) - if necessary, further certificates VEGAPULS 67 consists of the following components: Process fitting with encapsulated antenna system Housing with electronics, optionally available with plug connector, optionally available with connection cable Housing cover, optionally available with indicating and adjustment module PLICSCOM The components are available in different versions. 32938-EN-080610 10 VEGAPULS 67 • 4 … 20 mA/HART Product description Fig. 1: VEGAPULS 67 - version with plastic housing Housing cover with integrated PLICSCOM (optional) Housing with electronics Process fitting with plastic horn antenna Antenna cover 3.2 Principle of operation Application range VEGAPULS 67 is a radar sensor in K-band technology for continuous level measurement in solids. Functional principle The antenna of the radar sensor emits short radar pulses with a duration of approx. 1 ns. These pulses are reflected by the product and received by the antenna as echoes. The running time of the radar pulses from emission to reception is proportional to the distance and hence to the level. The determined level is converted into an appropriate output signal and outputted as measured value. Voltage supply Two-wire electronics 4 … 20 mA/HART for power supply and measured value transmission over the same cable. The supply voltage range can differ depending on the instrument version. 32938-EN-080610 Data for power supply are specified in chapter "Technical data". The backlight of the indicating and adjustment module is powered by the sensor. The prerequisite for this is a supply voltage at a certain level. The exact voltage specifications are stated in chapter "Technical data". VEGAPULS 67 • 4 … 20 mA/HART 11 Product description The optional heating requires its own power supply. You can find detailed information in the supplementary instructions manual "Heating for indicating and adjustment module". This function is generally not available for approved instruments. 3.3 Operation VEGAPULS 67 can be adjusted with different adjustment media: with indicating and adjustment module with the suitable VEGA DTM in conjunction with an adjustment software according to the FDT/DTM standard, e.g. PACTware™ and PC with manufacturer-specific adjustment programs AMS™ or PDM With a HART handheld The entered parameters are generally saved in VEGAPULS 67, optionally also in the indicating and adjustment module or in PACTware™. 3.4 Packaging, transport and storage Packaging Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test according to DIN EN 24180. The packaging of standard instruments consists of environment-friendly, recyclable cardboard. For special versions, PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies. Transport must be carried out under consideration of the notes on the transport packaging. Nonobservance of these instructions can cause damage to the device. Transport inspection The delivery must be checked for completeness and possible transit damage immediately at receipt. Ascertained transit damage or concealed defects must be appropriately dealt with. Storage Up to the time of installation, the packages must be left closed and stored according to the orientation and storage markings on the outside. Unless otherwise indicated, the packages must be stored only under the following conditions: 12 VEGAPULS 67 • 4 … 20 mA/HART 32938-EN-080610 Transport Product description Storage and transport temperature Storage and transport temperature see "Supplement Technical data - Ambient conditions" Relative humidity 20 … 85 % 32938-EN-080610 Not in the open Dry and dust free Not exposed to corrosive media Protected against solar radiation Avoiding mechanical shock and vibration VEGAPULS 67 • 4 … 20 mA/HART 13 Mounting Mounting 4 Mounting 4.1 General instructions 4 Mounting Mounting position Mounting position Moisture Moisture The VEGAPULS 67 must be mounted such that it isfor pointing Select an installation position you can easily reach downward inside enclosedas metal, concrete, or fibre-reinforced mounting and connecting well as later retrofitting of an 4.1 General instructions plastic vessels only. Any other useThe is prohibited. Select indicating and adjustment module. housing can be rotated an position you canyou easily reach for mounting by installation 330°anwithout the use of any tools. can also install the Select installation position canYou easily reach for and connecting as well asas later retrofitting of an indicating indicating and connecting adjustment module in later four different positions mounting and well as retrofitting of an and adjustment module. housing be rotated (each displaced by 90°). The indicating and adjustment module. Thecan housing can bebyrotated 330° without thethe useuse of any tools. YouYou can can alsoalso install the the by 330° without of any tools. install Use the recommended cables (seein "Connecting to indicating and module four positions indicating and adjustment adjustment module inchapter four different different positions power supply") and tighten the cable gland. (each displaced by 90°). (each displaced by 90°). You can give your instrument additional protection against Use the recommended cables (see chapter "Connecting to moisture penetration by leading the connection cable downpower supply") and tighten the cable gland. ward in front of the cable entry. Rain and condensation water can thus drainyour off. This appliesadditional mainly toprotection outdoor mounting You can give instrument against as well as installation in areas wherethe high humidity iscable expected moisture penetration by leading connection down-(e. g. through cleaning processes) on and cooled or heated water ward in front of the cable entry. or Rain condensation vessels. can thus drain off. This applies mainly to outdoor mounting as well as installation in areas where high humidity is expected (e. g. through cleaning processes) or on cooled or heated vessels. Fig. 2: Measures against moisture penetration Measuring range The reference plane for the measuring range of the sensors is the contact surface on the side of the antenna cover. Fig. 2: Measures against moisture penetration Measuring range The reference plane for the measuring range of the sensors is the contact surface on the side of the antenna cover. VEGAPULS 67 • 4 … 20 mA/HART 14 VEGAPULS 67 • 4 … 20 mA/HART 32938-EN-080610 32938-EN-080610 14 -
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-702 Modify Date : 2008:09:23 08:54:12-07:00 Create Date : 2008:09:23 08:52:58-07:00 Metadata Date : 2008:09:23 08:54:12-07:00 Creator Tool : Adobe Acrobat 8.1 Combine Files Format : application/pdf Title : Operating Instructions - VEGAPULS 67 - 4 ? 20 mA/HART Creator : VEGA Document ID : uuid:18cbb538-f7c4-46a0-8534-ac8156556a2c Instance ID : uuid:4681da68-c50e-43cd-94a6-5b66b209b830 Producer : Adobe Acrobat 8.1 Has XFA : No Page Count : 37 Author : VEGAEXIF Metadata provided by EXIF.tools