Zebra Technologies WMC6300704 PCMCIA Card User Manual VMM User s Guide

Zebra Technologies Corporation PCMCIA Card VMM User s Guide

EWR Users Manual

Enhanced Wireless
Router
User’s Guide
Version 3.0
Copyright 2003-2004, MeshNetworks, Inc. All Rights Reserved
MEA EWR User’s Guide
Foreword
This document describes in detail the confidential and proprietary technology of MeshNetworks’
MEA™ Architecture. MeshNetworks’ products and technology are protected by US and
international patent and patent pending technology. This document represents the current MEA
design; the contents are subject to change at any time at the discretion of MeshNetworks, Inc.
MEA, MeshTray, and MeshNetworks’ logo are trademarks or registered trademarks of
MeshNetworks, Inc. All other product names and services identified throughout this publication
are trademarks or registered trademarks of their respective companies. No such uses or the
use of any trade name is intended to convey endorsement or other affiliation with this
publication.
Copyright © 2003-2004 MeshNetworks, Inc. All Rights Reserved
i
MEA EWR User’s Guide
Table of Contents
1 ENHANCED WIRELESS ROUTER.......................................................................................1
1.1 Introduction.................................................................................................................1
1.2 What’s in the Box .......................................................................................................1
2 INSTALLATION REQUIREMENTS.......................................................................................1
2.1 Enhanced Wireless Router (EWR) ............................................................................2
2.1.1 Equipment .........................................................................................................2
2.1.2 Record MAC Address of the EWR6300 ............................................................3
2.1.3 EWR6300 Assembly..........................................................................................4
2.1.4 Deployment .......................................................................................................4
2.1.5 Deployment Tips................................................................................................5
2.1.6 Initial Configuration............................................................................................5
2.1.7 Testing...............................................................................................................5
3 INSTALLING THE MEA ENHANCED WIRELESS ROUTER...............................................7
3.1 Device Administration: Configuring the EWR Devices...........................................7
3.1.1 Accessing the MEA Device Administration Web Pages....................................7
3.1.2 Configuring the Device ....................................................................................11
3.1.2.1 Device Addressing.......................................................................................12
3.1.2.2 Network DHCP Scheme..............................................................................12
3.1.2.3 Statically Provisioned Scheme ....................................................................13
3.1.2.4 User Supplied Scheme................................................................................13
3.1.2.5 Setting the User Supplied IP Address .........................................................14
3.1.3 Resetting the EWR..........................................................................................16
3.1.4 Restoring Factory Settings – User Supplied Mode Limitations .......................18
3.1.4.1 EWR Reset-to-Default Recovery In User-Supplied Mode ...........................18
3.1.4.2 Reset the Device Addressing Mode Using DeviceManager........................18
3.1.4.3 Reset the Device Addressing Mode via the Configuration Web Page.........18
iii
MeshNetworks
3.1.4.4 Reset the User-Supplied Parameters via the Configuration Web Page......18
3.1.5 Restoring Factory Defaults – Normal Operations............................................19
3.1.6 Changing the Web Password..........................................................................21
3.1.7 Upgrading the Device Firmware......................................................................23
3.2 External Device Provisioning..................................................................................25
3.2.1 Connecting to the Ethernet Port ......................................................................26
3.3 Infrastructure Requirements ...................................................................................26
3.4 EWR6300 Mounting Bracket....................................................................................27
3.4.1 EWR MAC Addresses .....................................................................................29
4 LICENSE AND WARRANTY INFORMATION ....................................................................30
4.1 Important Information ..............................................................................................30
5 FCC REGULATORY INFORMATION.................................................................................32
5.1 FCC Information .......................................................................................................32
5.2 FCC RF Radiation Exposure Statement .................................................................32
6 SAFETY INFORMATION FOR THE MEA PRODUCTS .....................................................33
7 SAFETY CERTIFICATION..................................................................................................33
7.1 CE Mark Certification ...............................................................................................33
iv
MEA EWR User’s Guide
List of Figures
Figure 2-1. EWR6300 Identification Label ............................................................................3
Figure 2-2. EWR6300 External Connection Points ..............................................................4
Figure 2-3 Typical EWR Depoyment ....................................................................................5
Figure 3-1. Enter Network Password Initial Web Page Authentication Dialog .................8
Figure 3-2. MEA Device Administration Redirecting Web Page.........................................9
Figure 3-3. MEA Device Administration Home Page (Super User Login)........................10
Figure 3-4. EWR Device Administration Configuration Page (Super User Login)..........11
Figure 3-5. Configuration Change Verification ..................................................................14
Figure 3-6. System Update Save Completed Web Page ...................................................15
Figure 3-7. Device Reset Prompt Web Page ......................................................................16
Figure 3-8. Device Reset in Progress Web Page ...............................................................17
Figure 3-9. Restore Factory Settings Web Page................................................................19
Figure 3-10. Confirm Changes Window for Restore Factory Settings .........................20
Figure 3-11. Factory Settings Restored Web Page..........................................................20
Figure 3-12. Enter New Password Web Page..................................................................21
Figure 3-13. Confirm Changes Window for Enter New Password .................................22
Figure 3-14. Password Changed Confirmation Web Page..............................................22
Figure 3-15. Update Device Firmware Web Page.............................................................23
Figure 3-16. Confirm Upload Window for Firmware Update..........................................24
Figure 3-17. Firmware Upload Progress Web Page.........................................................24
Figure 3-18. External Device Provisioning Table.............................................................25
Figure 3-19. EWR6300 Mounting Bracket.........................................................................27
Figure 3-20. C-Clamp Bracket Assembly..........................................................................28
Figure 3-21. EWR Pivot and Angle Locking Bolts ...........................................................29
v
MEA EWR User’s Guide
1 Enhanced Wireless Router
1.1 Introduction
Thank you for purchasing the MEA Enhanced Wireless Router (EWR). MEA is a wireless
communication system capable of supporting high data rate mobile communication at variable
rates of vehicular speeds.
The Enhanced Wireless Router (EWR™) is designed to be deployed outdoors for wireless
coverage in large geographic areas to wireless network access to one or more IP devices via its
built-in RJ45 Ethernet port. The EWR efficiently combines the functionality of a Meshnetworks
Wireless Router and client modem in to a single cost-effective wireless network component.
This makes it easy for any Ethernet ready device to access a Mesh Enabled Architecture
(MEA™) mobile broadband network. IP-enabled computers, video cameras, sensors, signs,
signals, etc. can all be Mesh-Enabled to send and receive data at burst rates of up to 6 Mbps.
All standard Wireless Router functionality including Multi-Hopping™, near line of sight
communications and geo-location services are fully supported.
The MEA Enhanced Wireless Router is configured for the connection of multiple IP addressable
devices using standard Ethernet connectivity. This allows devices that cannot accept the
PCMCIA based WMC3600 product to function transparently on a MEA network without drivers.
This document provides detailed installation and configuration instructions for installing the MEA
EWR.
1.2 What’s in the Box
Each MEA EWR is a full-featured wireless networking device. The following is a list of the items
provided with each EWR:
MEA Enhanced Wireless Router
High Gain Antenna
Power Cord
2 Installation Requirements
NOTE: All Intelligent Access Points (IAPs) on the MEA network require a software upgrade to
support EWR Devices.
The EWR will require the following in a typical installation:
Power Cord
110/220 volts AC Power along with appropriate power connection cable
A Hub or Switch (Use of a X-Over cable is not recommended at this time)
Antenna and RF cabling appropriate for use in the 2.4 GHz band
1
MeshNetworks
2.1 Enhanced Wireless Router (EWR)
The MEA Enhanced Wireless Router 6300 (EWR6300) is an infrastructure device positioned in
a fixed location, such as on a pole, wall, or rooftop. The EWR6300 requires professional
installation to ensure the installation is performed in accordance with FCC licensing regulations.
The EWR6300 provides range extension, a means to route around obstructions, a fixed location
reference for use in Geo-Location, and the capability of enabling IP devices.
The EWR6300 comes with a mounting bracket that can be attached to a pole with a diameter of
1-3.5 inches. For a MEA deployment, a power source for each EWR must be provided.
2.1.1 Equipment
The following list defines the standard MEA hardware components needed to set up a EWR:
EWR Box with N-type Antenna Connector
120V A/C Power Cable with a NEMA 5-15 plug
Antenna with N-type Male Antenna Connector
Mounting Bracket
The Network Operator must supply the following:
Mounting Location
Power Source (120V A/C or 5 V D/C depending on EWR configuration)
Hand tools for bracket installation (7/16” wrench (2), Phillips screwdriver)
Optional Equipment:
DC powered EWR (EWR6300-DC-IN)
Power cord to connect to a photoelectric cell
Optional FCC Approved Antennas:
Manufacturer Part Number Gain Usage
Maxrad MFB24008 8 dBi Infrastructure
Maxrad MFB24004 4 dBi Infrastructure
Hyperlink HG2409U 8 dBi Infrastructure
2
MEA EWR User’s Guide
2.1.2 Record MAC Address of the EWR6300
The transceiver Media Access Control (MAC) address is recorded on the label located on the
antenna end of the EWR6300 and the Ethernet MAC address is recorded on the label located
on the antenna end of the EWR6300 as show in Figure 2-1.
Record the MAC Address and ETH MAC Address in the tables in Section 3.4.1, because it will
be required later to configure and test the device.
ETH MAC
Address
MAC
Address
Figure 2-1. EWR6300 Identification Label
3
MeshNetworks
2.1.3 EWR6300 Assembly
Figure 2-2 shows the external connection points on a EWR6300 box.
Figure 2-2. EWR6300 External Connection Points
e:
nclosed bracket. Refer to the EWR6300
A
ntenna Connecto
r
Power Out (3-pin)
(
o
p
tional
)
Power In (4-pin)
Test Port
(Not Shown)
RJ45 (Data) Port
Assemble the EWR using the following procedur
1. If desired, mount the EWR box using the e
Mounting Bracket section.
2. N-type Connector on the top of the box, and rotate to close.
3.
4. address has been recorded in Section
Insert the Antenna into the
Insert the Power Plug into the 4-pin Connector.
Verify the MAC address and Ethernet (ETH)
3.4.1. Both addresses will be required to configure and test the device.
5.
2.1.4
unted on a pole by using the bracket provided.
minimum of 30 inches
from the body
provided with antenna installation and transmitter
Typically, enh k to extend the range,
e device.
ny
The Test Port is unused during deployment.
Deployment
The EWR6300 can be mo
NOTE: When deploying the EWR6300, the antenna should be a
from any nearby metal poles to avoid distortion of the RF pattern.
The antenna must have a separation distance of at least 2 meters
of all persons and must not be co-located or operating in conjunction with any
other antenna or transmitter.
Users and installers must be
operating conditions to satisfy RF exposure compliance.
anced wireless routers are distributed within a networ
guarantee coverage, and mesh enable an Ethernet Internet Protocol (IP) device. A rule of
thumb is to deploy 2-3 hop networks to optimize range, latency, and throughput.
The EWR6300 installation location must provide applicable AC or DC power for th
It is the responsibility of the Network Operator to ensure that the installation complies with a
local building codes and permits.
4
MEA EWR User’s Guide
Figure 2-3 Typical EWR Depoyment
2.1.5 Deployment Tips
multipath:
rference from nearby transmitters
nnection to other
nna supplied is designed to be mounted vertically
he devices are designed to be vertically mounted with the antenna port at the top or the
2.1.6 Initial Configuration
Location is the same as the setup for the IAP as described in
2.1.7 Testing
of the EWR6300 using the following procedure:
1. Apply power to the EWR6300.
dress and ETH address that was recorded in Section
Locate the antenna to minimize
Minimize inte
Maximize chance of a direct line of sight co
devices
The ante
T
bottom. The antenna is specified around deployment heights of 3-30 meters. Remotely locating
the antenna will degrade the performance through cable loss, though this may be mitigated by
better antenna positioning.
The configuration process for Geo-
the mea Setup and Deployment User’s Guide for Infrastructure Mode User’s Guide.
Verify the operation
2. Obtain the transceiver MAC ad
3.4.1. The address will be in the form of 00-05-12-0A-xx-yy.
3. he MAC address.
o test
communications with the device.
From the MeshManager user interface, display devices using t
4. Select the appropriate EWR in the device tree, right click and select ping t
5
MeshNetworks
nse to the ping command verifiesA respo that the transceiver is communicating.
NOTE: If you are running an EWR as a standalone device, the configuration web page can be
reached by connecting a PC to the wired interface.
6
MEA EWR User’s Guide
3 Installing the MEA Enhanced Wireless Router
3.1 Device Administration: Configuring the EWR Devices
The EWR provides network access to one or more IP devices connected to the Ethernet port of
the EWR. In order for the EWR to provide service to the IP devices, some configuration must
be set up prior to connecting the IP devices.
The EWR serves as a default gateway for the attached IP devices. Because some devices
expect the default gateway to reside on the local subnet, the address that the EWR uses for
gateway service (on the wired interface) must be configurable. Some consideration should be
used in selecting a gateway address for the EWR.
The local default gateway address is used only on the wired interface, and is only visible to the
attached IP devices. It is not advertised to the wireless network, and the network cannot
access the EWR using this gateway address. The EWR has another IP address for the
wireless interface that can be used to access the EWR from the network. Because is gateway
address is limited to the local wired interface, the same address could be used for the gateway
service in several EWR devices. The local gateway should be a part of the overall subnet
chosen for your MEA network.
When selecting IP addresses for the EWR, care must be taken to ensure that the selected IP
addresses do not conflict with any other devices on the mea network.
3.1.1 Accessing the MEA Device Administration Web Pages
To modify the IP configuration for the EWR using the web interface, you must know the IP
address assigned to the wireless interface of the EWR. The IP address can be determined
from MeshManager, or from the DHCP server (once the device is configured for DHCP). The
default IP address for the EWR wireless interface is derived from the transceiver MAC address
(10.xx.yy.1, where the MAC address is 00:05:12:0A:XX:YY), similar to the default IP addresses
described in Section 3.2.
Once the IP address is known, you can access the web page of the device. Point your web
browser to the IP address of the EWR. In the examples following, the EWR address is
172.16.1.53, and the web page would be found at http://172.16.1.53/.
7
MeshNetworks
Once the web browser is directed to the web page of the EWR, you will be prompted for a
username and password. A dialog box similar to the following should show up if you are using
Internet Explorer:
Figure 3-1. Enter Network Password Initial Web Page Authentication Dialog
The username is admin, and the default (initial) password is admin.
The password for the admin account should be changed during installation.
The device has two accounts for the web pages - an administrative account (username:admin,
default password:admin), and an access account (username: monitor, default password:
monitor). The administrative account must be used for provisioning the device, and the access
account may be used for monitoring the status of the device.
The installation procedure described here requires administrator access. Alternatively, all of the
parameters that are provisioned via the web page may be provisioned via MeshManager
instead.
The administrator has the ability to change the password for the access account.
NOTE: If you are running an EWR as a standalone device, the configuration web page can be
reached by connecting a PC to the wired interface.
8
MEA EWR User’s Guide
After the login authentication has been completed, the web browser will display a redirecting
page, and your browser will automatically transition to the home web page for MEA Device
Administration.
Figure 3-2. MEA Device Administration Redirecting Web Page
9
MeshNetworks
Figure 3-3. MEA Device Administration Home Page (Super User Login)
The MEA Device Administration home page provides you with some basic information about
the device, including the IP addresses assigned to the device, the MAC addresses of the
device, the firmware revision number, and the reported link quality for the link to the IAP. In
addition, links are provided to web pages for device configuration, password management,
firmware upgrades, device reset, and restoring the factory default configuration.
10
MEA EWR User’s Guide
3.1.2 Configuring the Device
Once you have accessed the MEA Device Administration home page, click on the
Configuration tab to display the IP address configuration.
Figure 3-4. EWR Device Administration Configuration Page (Super User Login)
The EWR Device Administration (Super User Login) page will allow you to change the
configuration of the EWR. The fields displayed on this page are described below.
Field Name Field Description Field Default Value
System Name This is the name of the device as shown by
MeshManager
11
MeshNetworks
Field Name Field Description Field Default Value
MeshManager
RDATE Server IP
Address The IP address of the RDATE server. This is
usually the MiSC when operating in
infrastructure mode. The RDATE server
provides the current date to the EWR. The
EWR can operate without an RDATE server.
172.31.0.20
Wired Interface
Address The EWR will tell the attached Ethernet devices
to use this address for the default gateway, and
the EWR will use the address when accessing
the local Ethernet segment.
MAC-derived
Wired Interface
Subnet Mask This is the subnet mask for the local Ethernet
segment. 255.255.0.0
DHCP Lease Time This is the duration (in seconds) of the DHCP
leases that the EWR offers to the attached
Ethernet devices.
300
Device Priority The Device Priority provisioning area allows the
operator to set the priority assigned to wireless
messages transmitted by this device.
Geo Reference The Geo Reference area allows the operator to
provision the exact location of the EWR so that
it can serve as a geographical reference for the
mea network. Enter the Latitude and Longitude
in degrees and the Altitude in feet.
The External Device Provisioning frame of this web page is described in Section 3.2.
A similar screen will be displayed for the access account (the web page will indicate Normal
User Login). Normal users can change only those settings for which they have system
privileges.
3.1.2.1 Device Addressing
With mea Release 3.0, the concept of modes has been replaced by a Unified Modes of
operation addressing scheme. The concept of unified modes of operation centers on the current
state of network communication: Associated State and Unassociated State. There are three
addressing schemes which allow the IT manager increased flexibility in deployment.
3.1.2.2 Network DHCP Scheme
Operation under the Network DHCP scheme is similar to that of Release 2 in Infrastructure
Mode. The primary difference is that loss of infrastructure does not force loss of connectivity.
Network DCHP requires that the EWR device be configured to request an address from a
DHCP server and the inclusion of a DHCP server in the core network configuration to answer
these requests. With Network DHCP selected, the EWR will send DHCP requests for its own
address to the core network once it becomes associated and establishes communications with
the infrastructure.
12
MEA EWR User’s Guide
The server may be configured by the operator to hand out temporary or static leases. The EWR
must associate and acquire an address from the network before establishing communications.
Once a lease has been granted, the address may be dragged out of network coverage for the
remainder of the lease or, if a static lease was granted, until the next power cycle. If the lease
expires or the user cycles power while outside of network coverage, the user will again lose the
ability to communicate with the wireless network.
This scheme is best for a larger, closely managed network of subscribers who don't need to
communicate or communicate only briefly outside of network coverage.
3.1.2.3 Statically Provisioned Scheme
Operation under the Statically Provisioned scheme is similar to that of Release 2 in Peer-to-
Peer Mode. The primary difference is that addresses are configured by the network operator
rather than hashed from the MAC address. This serves to eliminate the 10.x.x.x limitation on the
network range.
When operating under the Statically Provisioned scheme, the EWR device will use provisioned
DHCP-like information to establish an IP address for use in the wireless network.
This scheme does not require a DHCP server on the core network.
It should be noted that a DHCP server can still exist on the network to hand out addresses to
other nodes using the Network DHCP Scheme as long as the server's address range does not
conflict with addresses assigned to devices using the Statically Provisioned or User Supplied
Schemes.
The IP addresses and options used are configurable per-device using MeshManager. The
provisioned address may be freely used to communicate while associated or unassociated.
The operator must ensure that the provisioned addresses are routable and do not conflict with
any other addresses in use. The operator is free to provision any option ordinarily provisioned
by a DHCP server (subnet mask, DNS, etc.) through programming of the appropriate fields in
each device using MeshManager.
This scheme is ideal for a managed network of users who regularly need to communicate inside
and outside of network coverage or for a network lacking a DHCP server.
3.1.2.4 User Supplied Scheme
Operating under the User Supplied scheme, the EWR device is configured to use a fixed IP
address and subnet mask. The user is responsible for configuring options that would otherwise
be configured by a DHCP server.
It is also up to the user to ensure that the assigned address is routable on the core network (if
core network access is needed) and that it does not conflict with other addresses in use. This is
analogous to and carries the same caveats as plugging an Ethernet card into a LAN and
manually assigning an address to the card.
The user is free to communicate while associated or unassociated. This scheme is ideal for
small, unmanaged networks lacking a DHCP server.
All of these schemes may be assigned per device, either by the user or by the network
manager. The network manager can also limit the user-selectable schemes or force a specific
scheme. Devices in each of these schemes can interoperate and communicate with each other,
so long as the assigned addresses do not conflict and are mutually routable.
13
MeshNetworks
3.1.2.5 Setting the User Supplied IP Address
In order to set the user-supplied IP address for the EWR, the User-Supplied radio button must
be selected. At that point, the user may enter an IP address, subnet mask consistent with the
existing network. The user should also enter the IP address of the default gateway and DNS
server, as well as enter the domain name.
Note that this configures the user-supplied address for the EWR device. To configure addresses
for ethernet clients, please refer to the description of the External Device Provisioning frame of
this web page in Section 3.2.
A similar screen will be displayed for the access account (the web page will indicate Normal
User Login). Normal users can change only those settings for which they have system
privileges.
When the desired configuration has been completed, click on the Apply button on the Device
Addressing panel on the Device Administration Configuration Page. You will be prompted to
verify that the changes to the configuration are correct before the changes are actually applied.
Figure 3-5. Configuration Change Verification
When you click on the OK button, the configuration will be saved in Flash. The System
Settings Have Been Saved message on the System Update Save Completed page will then
confirm the changes have been saved.
14
MEA EWR User’s Guide
Figure 3-6. System Update Save Completed Web Page
After the settings have been saved, click the Finished button. Your web browser should return
to the MEA Device Administration home page. A reboot of the device is not required for the
changes to take effect.
15
MeshNetworks
3.1.3 Resetting the EWR
Although you should not have to reset the EWR device, the device can be commanded to reset
via the web pages. In order to reset the device, return to the MEA Device Administration home
page, and click on the Reset the Device link in the Device Management panel.
The web page displayed will allow you to reset the device.
Figure 3-7. Device Reset Prompt Web Page
Once you have commanded the device to reset, the following screen will be displayed. Your
browser will delay for a short time, then transition to the home page once more.
16
MEA EWR User’s Guide
Figure 3-8. Device Reset in Progress Web Page
NOTE: After the completion of the reset, you may experience a significant delay when bringing
up another web page. Please be patient.
17
MeshNetworks
3.1.4 Restoring Factory Settings User Supplied Mode Limitations
NOTE: In Release 3.0, there is a known issue that arises if the selected device addressing
mode is User-Supplied when the user restores the factory default settings for the
EWR. The following options are offered as a way to recover from this limitation.
3.1.4.1 EWR Reset-to-Default Recovery In User-Supplied Mode
The factory default settings for the User-Supplied parameters cannot be routed (i.e. 0.0.0.0).
When the non-routable values are applied, the network connection between the attached
ethernet devices and the core network becomes disabled.
There are three options available to recover from this situation and restore the connection to
the core network.
3.1.4.2 Reset the Device Addressing Mode Using DeviceManager
DeviceManager will be able to manage some but not all of the device parameters at this time.
The network operator may change the selected device addressing mode via DeviceManager to
either Remote-DHCP or Statically-Provisioned.
3.1.4.3 Reset the Device Addressing Mode via the Configuration Web Page
Because the factory default settings were restored, the EWR will offer one IP address via
DHCP. This address will be in the form 10.xx.yy.10, where xx and yy are based on the
transceiver MAC address as described in the EWR User’s Manual. The EWR will be accessible
via the 10.xx.yy.9 address, also described in the EWR User’s Manual. Once an ethernet device
has been attached to the EWR, the configuration web page may be accessed at the 10.xx.yy.9
address and the device addressing mode may be changed to either Remote-DHCP or
Statically-Provisioned.
Please be aware that the access password for the web page will have also been reset.
3.1.4.4 Reset the User-Supplied Parameters via the Configuration Web Page
If the allowed device addressing modes were restricted to User-Supplied, the user may still
connect to the EWR as described above and access the configuration web page. The User-
Supplied parameters may then be set to usable values.
18
MEA EWR User’s Guide
3.1.5 Restoring Factory Defaults – Normal Operations
When the Restore Factory Defaults function is selected from the EWR Device Administration
Home Page, the device will present the following web page:
Figure 3-9. Restore Factory Settings Web Page
The Restore Factory Defaults function allows the operator to return the device to factory
defaults. This change will include the web password for the administrator and access accounts.
This will also return the local IP addresses to the default MAC-derived values. Click on the
Apply button to restore the device factory settings.
The confirmation window will be displayed. Click on the OK button to confirm the action.
19
MeshNetworks
Figure 3-10. Confirm Changes Window for Restore Factory Settings
The Factory Settings Restored page will be displayed.
Figure 3-11. Factory Settings Restored Web Page
Click on the Finished button to complete the reset procedure.
20
MEA EWR User’s Guide
3.1.6 Changing the Web Password
When the Change Admin Password function is selected from the EWR Device Administration
Home Page by the administrator, or the Change User Password function is selected, the device
will present the following web page:
Figure 3-12. Enter New Password Web Page
The operator is expected to enter a new password for the web account and click on the
Submit” button. Once the password entry is complete, the device will prompt the operator for
confirmation of the change.
21
MeshNetworks
Figure 3-13. Confirm Changes Window for Enter New Password
When the operator confirms the change, the new password will be stored in flash, and the
device will present a status screen indicating that the change was successful.
Figure 3-14. Password Changed Confirmation Web Page
22
MEA EWR User’s Guide
3.1.7 Upgrading the Device Firmware
The web interface for the device also provides the ability to upgrade the firmware on-site. To
use this feature, you must have an upgrade file from a released upgrade package.
When the Upgrade Device Firmware function is selected from the EWR Device Administration
Home Page, the device will present the following web page:
Figure 3-15. Update Device Firmware Web Page
This page allows entry of the name (and path) of the upgrade file. Once the correct filename has
been entered, the device will prompt for confirmation:
23
MeshNetworks
Figure 3-16. Confirm Upload Window for Firmware Update
Once the filename has been confirmed, the web browser will transmit the file to the device, and
the device will present an upgrade progress screen. This page will indicate the current stage in
the upgrade process.
Figure 3-17. Firmware Upload Progress Web Page
Once the upgrade is completed, the device must be reset. The Finished button will transition
the web browser to the reset screen.
24
MEA EWR User’s Guide
3.2 External Device Provisioning
Figure 3-18. External Device Provisioning Table
The External Device Provisioning table is used to configure addresses for the attached nodes
on the local ethernet segment. Up to three addresses are provisioned.
The Enable checkbox indicates this row contains a valid address. Any address can be
disabled by clearing the checkbox. The pull-down menu options indicate whether this address
will be offered via the local DHCP service (“Local-DHCP”) or not (“Statically-Provisioned”).
The Statically-Provisioned setting is used to support devices that do not use DHCP to acquire
an address.
The MAC address field is used for Local-DHCP addresses, so that the IP address can be
reserved for a specific device. The reserved checkbox must be marked for this kind of IP
address reservation. The Status field indicates whether the provisioned IP address was
detected (via a ping) when the web page was brought up.
25
MeshNetworks
The IP addresses default to values based on the transceiver MAC address of the device. The
derivation is described below. By default, only the first IP address is enabled (for local-DHCP),
and no addresses are reserved for specific MAC addresses.
Please make sure to check the checkbox for the client IP addresses you have entered. Client
2 and Client 3 are not enabled by default. In this example, the EWR wired interface is assigned
the IP address 172.16.2.1. This address is hidden from the core network and the IAP will not
route for this address. The core network must use the 172.16.1.37 address to access the EWR
(which is the address obtained via MeshManager).
The EWR has two interfaces and must use two IP addresses. The wireless network must use
the IP address on the wireless interface because that is the address for which the IAP will
proxy and advertise. The same address will be accessed by the DeviceManager when using
MeshManager.
The wired interface address will be used by the EWR as the gateway address for the local
ethernet segment. The wired subnet mask is configurable so that the user may select a more
restrictive subnet on the local ethernet segment than what is normally provided to the wireless
subscribers.
The MAC-derived default values are a means to ensure that these devices are likely to work
out-of-the-box. The IP addresses are derived as follows:
Transceiver MAC address: 00:05:12:0A:XX:YY
Derived MAC addresses:
Local gateway: 10.xx.yy.9
Client1: 10.xx.yy.10
Client2: 10.xx.yy.11
Client3: 10.xx.yy.12
Where XX and YY are hex values (from the transceiver MAC address), and the lowercase xx
and yy are the same values in decimal. For example, an EWR with transceiver MAC address of
00:05:12:0A:80:20 would have a default local gateway address of 10.128.32.9.
The user is encouraged to change these addresses upon installation.
3.2.1 Connecting to the Ethernet Port
If only one device is to be connected to the EWR, you will need to connect the device using a
crossover cable.
If you are going to connect more than one device to the EWR, you will need to connect a hub to
the EWR and connect the other devices to the hub. A straight through cable will be used
between an EWR and a hub.
3.3 Infrastructure Requirements
The EWR requires an associated IAP load to support the additional addresses the EWR makes
available. All IAPs must have the appropriate software installed to support the EWR.
26
MEA EWR User’s Guide
3.4 EWR6300 Mounting Bracket
The mounting bracket for the IAP6300 and the MWR6300 are identical to mounting bracket for
the EWR6300. The bracket is robust secure; and can be used for horizontal, vertical, and off-
angle pole mounted installations. The mounting bracket is preinstalled and supplied with two 3
1/2 x 1/4 inch stainless steel bolts. The mounting bracket can accommodate up to a 3 1/4 inch
diameter mounting pole. Substitute for the 1/4-inch bolts supplied with the bracket may be used
to accommodate mounting poles smaller than 3 inches.
MeshNetworks strongly recommends the use of stainless steel mounting hardware to prevent
corrosion. The standard mounting hardware supplied with the bracket is stainless steel. The
bracket is made of aluminum.
The following procedure outlines the required steps for installing a MEA EWR6300 the bracket
shown in Figure 3-19.
Figure 3-19. EWR6300 Mounting Bracket
Using the deployment guidelines described in the mea Setup and Deployment User’s
Guide, locate an appropriate mounting pole such at a streetlight cobra arm or a metal
post. The mounting pole can be vertical, horizontal, or project at almost any angle.
1.
2. Remove one of the C-Clamp Bracket bolts so that the bracket can be positioned around
the mounting pole. If necessary, remove the second bolt. When the two halves of the
Clamp Bracket are correctly positioned, reinstall the bracket bolts.
Note: The C-Clamp Bracket Assembly requires two 3 1/2 x 1/4 inch stainless steel bolts
to secure the C-Clamp to a mounting pole. Each bolt is supplied with (2) stainless steel
flat washers, (1) lock washer, and (1) stainless steel nut. The bracket hardware should
be installed as indicated in Figure 3-17.
27
MeshNetworks
3 1/2 x 1/4 inch bolt
1/4 Flat Washer
1/4 Flat Washer
1/4 Lock Washer
1/4 Hex Nut
Note: All Hardware is Stainless Steel
Figure 3-20. C-Clamp Bracket Assembly
3.
4.
Position the bracket in the desired location and securely tighten the two bracket bolts.
If required, loosen the Pivot Bolt and the Angle Locking Bolt (Figure 3-18) so that the
antenna connector is positioned vertically.
5.
6.
Tighten the Angle Locking Bolt using a #1 Phillips screwdriver.
Ensure that the antenna connector is still vertical and tighten the Pivot Bolt using a 7/16-
inch open-end wrench or socket wrench.
28
MEA EWR User’s Guide
6 x 32 x 3/4
Angle Locking Bolt
1/4 x 1 inch Pivot Bolt
(Requres 7/16 Wrench)
Figure 3-21. EWR Pivot and Angle Locking Bolts
NOTE: Some IAP6300 and MWR6300 enclosures may have a bolt or plug in the center of the
back of the box. To maintain the integrity of the box, DO NOT REMOVE THIS PLUG.
3.4.1 EWR MAC Addresses
This table has been included for recording the Ethernet MAC address and transceiver MAC
address for a set of EWR devices as a quick reference. These addresses will be required for
configuration and management of these devices.
EWR MAC Address
00-05-12-0A-xx-yy
EWR ETH MAC Address
00-05-12-30-xx-yy
29
MeshNetworks
4 License and Warranty Information
4.1 Important Information
PLEASE READ CAREFULLY THE FOLLOWING BEFORE INSTALLING OR USING THIS HARDWARE,
CONSISTING OF A CD ROM AND PCMCIA CARD, AND THE SOFTWARE (COLLECTIVELY, THE “PRODUCT”).
IF YOU AGREE WITH ALL OF THE TERMS OF THIS LICENSE AGREEMENT & LIMITED WARRANTY, PROCEED
WITH THE INSTALLATION AND USE OF THE PRODUCT FOLLOWING THE ONSCREEN INSTRUCTIONS. IF
YOU DO NOT AGREE, DO NOT INSTALL OR USE THE PRODUCT. BY INSTALLING OR USING THE PRODUCT,
YOU ARE AGREEING TO BE BOUND BY ALL OF THE TERMS OF THIS LICENSE AGREEMENT & LIMITED
WARRANTY. IF YOU DO NOT AGREE TO THE TERMS OF THIS LICENSE AGREEMENT & LIMITED
WARRANTY, PROMPTLY RETURN THE UNUSED PRODUCT AND DOCUMENTATION TO THE SOURCE (AS
DEFINED BELOW) FOR A FULL REFUND OF THE PURCHASE PRICE.
License Agreement & Limited Warranty
LICENSE GRANT
MeshNetworks, Inc. ("MeshNetworks"), by and through its resellers and suppliers (collectively, the “Source”) hereby
licenses to the end-user (“You”) the software accompanying this Product ("Software"). You have right of possession
to the CD ROM on which the Software is recorded (in accordance with your arrangement with the Source), but
MeshNetworks retains title to the Software and related documentation. The license is non-exclusive, non-
transferable, non-sublicensable and confers a right to use only the machine-readable, object code form of the
Software for its normal and intended purpose by a single-user. You may make one backup copy of the Software in
machine-readable form, provided the backup copy is not installed or used on any electronic device. You must
reproduce on the backup copy the MeshNetworks’ copyright notice and any other proprietary legends that were on
the original copy of the Software.
RESTRICTIONS
You acknowledge that the Product contains copyrighted material, trade secrets and other proprietary material owned
by MeshNetworks, and that unauthorized use of such material may cause serious loss or damage to MeshNetworks.
You agree that You will not:
decompile, reverse engineer, disassemble, translate or reduce the Product to a human-perceivable form.
modify, adapt, pledge, lease, rent, share, lend, distribute, disclose or create derivative works based upon the
Product in whole or in part.
electronically transmit the Software from one computer to another or over a network.
transfer any of your rights in the Software, the backup copy of the Software, the media, the documentation,
or this License Agreement & Limited Warranty to another party.
use the Product for any unlawful or harmful purpose.
TERM, TERMINATION
This license is effective until terminated. You may terminate this license at any time by destroying the Software,
related documentation and all copies thereof. This license will terminate immediately without notice from
MeshNetworks if You fail to comply with any provision of this License Agreement & Limited Warranty. Upon
termination You must destroy the Software, related documentation and all copies thereof.
HARDWARE WARRANTY
MeshNetworks warrants to You that the hardware elements of the Product will be substantially free from material
defects in workmanship and materials, under normal use and service, for a period of one (1) year from the date of
acquisition from the Source.
Our sole obligation under this express warranty will be, at our option and expense, (1) to repair the defective
hardware element or, (2) deliver to You an equivalent hardware element to replace the defective item. Any hardware
element that is replaced will become our property. Replacement hardware elements may be new or reconditioned.
We warrant any replaced or repaired hardware elements for the greater of ninety (90) days from shipment, or the
remainder of the initial warranty period.
SOFTWARE WARRANTY
MeshNetworks warrants to You that the Software, except as noted below, will perform in substantial conformance to
its published program specifications, for a period of ninety (90) days from the date of acquisition from the Source. No
updates are provided under this warranty. Our sole obligation under this express warranty will be, at our option and
expense, to replace any defective software product, with software which substantially conforms to applicable
MeshNetworks’ published program specifications.
30
MEA EWR User’s Guide
You assume responsibility for the selection of the appropriate applications program and associated reference
materials. MeshNetworks makes no warranty or representation that the Software will meet your requirements or work
in combination with any hardware or applications software products provided by third parties, that the operation of the
Software will be uninterrupted or error free, or that all defects in the Software will be corrected.
WARRANTY SERVICE
You must contact the Source of the Product within the applicable warranty period to obtain warranty service
authorization. Dated proof of purchase may be required. A Return Material Authorization (RMA) number will be
issued. This number must be marked on the outside of the package. The Product must be packaged appropriately
for safe shipment and sent prepaid. It is recommended that returned Products be insured or sent by a method that
provides for tracking of the package. Responsibility for loss or damage does not transfer to the intended recipient
until the returned item is received by such party. We will make commercially reasonable efforts to ship the repaired
or replaced item to You, at our expense, not later than ten (10) business days after receipt of the defective Product.
We will retain risk of loss or damage until the Product is delivered to You.
We will not be responsible for any software, firmware, information, or Memory data belonging to You contained in,
stored on, or integrated with any Products returned to the Source for repair, whether under warranty or not.
WARRANTIES EXCLUSIVE, WARRANTY DISCLAIMER
TO THE FULL EXTENT ALLOWED BY LAW, THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE
AND ARE IN LIEU OF ALL OTHER WARRANTIES, TERMS, OR CONDITIONS, EXPRESS OR IMPLIED, EITHER
IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING, WITHOUT LIMITATION,
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, SATISFACTORY QUALITY,
CORRESPONDENCE WITH DESCRIPTION, INFORMATIONAL CONTENT, ACCURACY, SYSTEM
INTEGRATION, NON-INFRINGEMENT AND QUIET ENJOYMENT, ALL OF WHICH ARE EXPRESSLY
DISCLAIMED. WE DO NOT WARRANT THAT THE FUNCTIONS CONTAINED IN THE PRODUCT WILL MEET
YOUR REQUIREMENTS, THAT THE PRODUCT WILL BE COMPATIBLE WITH ANY OTHER SOFTWARE,
HARDWARE OR OPERATING SYSTEM, THAT THE OPERATION OF THE PRODUCT WILL BE
UNINTERRUPTED OR ERROR-FREE. WE NEITHER ASSUME NOR AUTHORIZE ANY OTHER PERSON TO
ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE
OR USE OF THIS PRODUCT.
WE WILL NOT BE LIABLE UNDER THIS WARRANTY IF TESTING AND EXAMINATION DISCLOSE THAT THE
ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY MISUSE,
NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO OPEN, REPAIR OR
MODIFY THE PRODUCT, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY
ACCIDENT, FIRE, LIGHTNING, OTHER HAZARDS.
LIMITATION OF LIABILITY
TO THE FULL EXTENT ALLOWED BY LAW, MESHNETWORKS EXCLUDES FOR ITSELF, ITS RESELLERS AND
SUPPLIERS AND THEIR RESPECTIVE DIRECTORS, OFFICERS, EMPLOYEES, OR AGENTS, ANY LIABILITY,
WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL,
CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE
OR PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATA, OR OTHER FINANCIAL LOSS ARISING
OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE,
FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF WE HAVE BEEN ADVISED OF THE POSSIBILITY
OF SUCH DAMAGES, AND LIMITS ITS LIABILITY TO REPAIR OR REPLACEMENT. AT OUR OPTION THIS
DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN
WILL FAIL OF ITS ESSENTIAL PURPOSE.
Some jurisdictions do not allow the exclusion or limitation of implied warranties or the limitation of incidental or
consequential damages for certain products supplied to consumers, or the limitation of liability for death or personal
injury, so the above limitations and exclusions may be limited in their application to You. When the implied warranties
are not allowed to be excluded in their entirety, they will be limited to the duration of the applicable written warranty.
This warranty gives You specific legal rights which may vary depending on local law.
EXPORT COMPLIANCE
You agree and certify that the Product will be utilized only in the United States of America or in compliance with
22CFR125.4(b)(9).
GOVERNING LAW
This License Agreement & Limited Warranty will be governed by the laws of the state of Florida, U.S.A., and by the
laws of the United States, excluding their conflicts of laws principles. Both the Uniform Computer Information
Transactions Act and the United Nations Convention on Contracts for the International Sale of Goods are hereby
excluded in their entirety from application to this License Agreement & Limited Warranty.
31
MeshNetworks
5 FCC Regulatory Information
5.1 FCC Information
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received; including interference that may cause undesired operation.
The EWR6300 (Enhanced Wireless Router) is an infrastructure device that is positioned at a
fixed location such as a building rooftop. The EWR6300 requires professional installation to
ensure that the installation is performed in accordance with FCC licensing regulations.
The EWR6300 (Enhanced Wireless Router) is an infrastructure device positioned in a fixed
location, such as on a pole, wall, or rooftop. The EWR6300 requires professional installation to
ensure the installation is performed in accordance with FCC licensing regulations.
Federal Communications Commission (FCC) Statement:
This Equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference in a commercial installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by MeshNetworks could void the
user’s authority to operate the equipment.
5.2 FCC RF Radiation Exposure Statement
CAUTION: This equipment complies with FCC RF radiation exposure limits set forth for
an uncontrolled environment. This equipment should be installed and operated with a
minimum distance of 2 meters between the antenna and your body.
7.
8. This Transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
32
MEA EWR User’s Guide
6 Safety Information for the MEA Products
The Federal Communications Commission (FCC) with its action in ET Docket 96-8 has adopted
a safety standard for human exposure to radio frequency (RF) electromagnetic energy emitted
by FCC certified equipment. MeshNetworks’ MEA products meet the uncontrolled
environmental limits found in OET-65 and ANSI C95.1, 1991. Proper operation of this radio
according to the instructions found in this manual and the hardware and software guides on the
MEA CD will result in user exposure that is substantially below the FCC recommended limits.
Do not touch or move the antenna(s) while the unit is transmitting or receiving.
Do not hold any component containing a radio such that the antenna is very close to or
touching any exposed parts of the body, especially the face or eyes, while transmitting.
Do not operate a portable transmitter near unshielded blasting caps or in an explosive
environment unless it is a type especially qualified for such use (Intrinsically Safe).
Do not operate the radio or attempt to transmit data unless the antenna is connected;
otherwise, the radio may be damaged.
Antenna use:
In order to comply with FCC RF exposure limits, dipole antennas should be located
at a minimum distance of 2 meters or more from the body of all persons.
7 Safety Certification
3041788
Conforms to UL STD ANSI/UL 60950 3rd Edition
Certified to CAN/CSA C22.2 NO. 60950-00
Equipment shall be suitable for use in Air pressure: 86kPa to106kPa.
7.1 CE Mark Certification
The CE mark is the official marking required by the European Community for all Electric and
Electronic equipment that will be sold, or put into service for the first time, anywhere in the
European community. It proves to the buyer or user that this product fulfills all essential safety
and environmental requirements as they are defined in the European Directives.
MeshNetworks Products are covered under the following product certification Europe:
ETSI EN 300 328 V 141 (2003-04)
33
MeshNetworks
34
Products covered - IAP6300, EWR6300 , WMC6300, and MWR6300
ETSI EN 301 489-1 (2002-08) and 301 489-17
Products covered - IAP6300, EWR6300 , WMC6300, and MWR6300
EN 55022:1998 and EN 55024:1998
Products covered - IAP6300, EWR6300 , WMC6300, and MWR6300
CENELEC EN 50360 and EN50371 – Specific Absorption Test - SAR
Products covered - WMC6300
The following countries are covered under the CE Mark:
Austria, Belgium, Demark, Finland, Germany, Greece, Ireland, Italy, Luxemburg, Netherlands,
Portugal, Spain, Sweden, UK
CE Marking on the product will gain you access to the European Economic Area (EEA). Some
countries may require a declaration of conformity, please check with your MeshNetworks sales
team for details.
An example of the CE Marking on a product label:
Alert
S
y
mbol
CE Mark
The alert symbol indicates that MeshNetworks products are not certified to operate in France.
Outdoor use in France is restricted to 10mW EIRP for band 2454 – 2483.5 MHz.

Navigation menu