Acrodyne NW8201E DIGITAL TELEVISION BROADCAST TRANSMITTER User Manual 32 NV8202 26 04 06 01 00

Acrodyne Industries, Inc. DIGITAL TELEVISION BROADCAST TRANSMITTER 32 NV8202 26 04 06 01 00

Users Manual Part 19

Download: Acrodyne NW8201E DIGITAL TELEVISION BROADCAST TRANSMITTER User Manual 32 NV8202 26 04 06 01 00
Mirror Download [FCC.gov]Acrodyne NW8201E DIGITAL TELEVISION BROADCAST TRANSMITTER User Manual 32 NV8202 26 04 06 01 00
Document ID864584
Application IDvnwefxrVtvE1edbLlVsrmQ==
Document DescriptionUsers Manual Part 19
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize232.06kB (2900787 bits)
Date Submitted2007-11-06 00:00:00
Date Available2008-01-18 00:00:00
Creation Date2007-11-02 12:39:24
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2007-11-02 12:39:40
Document Title32 NV8202-26.04.06-01.00.book
Document CreatorFrameMaker 7.0
Document Author: HUPFAUER

Chapter 8
Service
Harmonics Filter
In the Transmitter Family NW820x the harmonics filter is integrated into the RF line.
8.1
Replacing the Harmonics Filter
ATTENTION!
Always make sure that the power supply is disconnected before commencing any service
work on the transmitter rack; this will prevent injury caused by electric shock and damage
to the instruments.
Note
The harmonics filter is lacquered in order to reduce the surface temperature, but high temperatures are nevertheless to be expected.
8.1.1
Removing the Harmonics Filter
Note
The harmonics filter is connected to the RF chain by means of two rigid line brackets. So
that the inner line of the lower rigid line (into the bandpass) stays fixed in place, the tensioning clamp of the lower rigid line bracket should be opened first.
To remove the harmonics filter proceed as follows:
1. Open the tensioning clamp of the lower rigid line bracket on the rigid connection of the
combiner.
2. Open the tensioning clamp of the upper rigid line bracket using an open-end wrench
No. 7 or a Phillips screwdriver No. 2.
3. Pull the harmonics filter of the combiner rigid line down and to the right.
4. Pull the harmonics filter downward from the upper rigid line bracket.
2099.9595.72
- 8.26 -
E-2
Chapter 8
Service
Fig. 17 Removing the harmonics filter
8.1.2
Installing the Harmonics Filter
The replacement harmonics filter has no rigid line brackets.
) Remove the rigid line bracket from the old harmonics filter, attach the bracket to the new
harmonics filter (top) and screw it firmly in place.
To install the unit in the transmitter, reverse the procedure used to remove it.
2099.9595.72
- 8.27 -
E-2
Chapter 8
Service
Cooling System
You can replace the following cooling system components:
혖 Fan
혖 Starting capacitor
혖 Differential pressure gage
혖 Temperature sensors
9.1
Replacing the Fan
ATTENTION!
Always make sure that the power supply is disconnected before commencing any service
work on the transmitter rack; this will prevent injury caused by electric shock and damage
to the instruments.
The transmitter rack contains two fans as standard; one of these can be reached only from
the front and the other only from the back. However the removal sequence is the same in
both cases.
9.1.1
Removing the Fan
Note
Prior to removal make sure which of the two fans needs to be replaced.
1. Using a Torx screwdriver No. 20, remove the front panel of the power distribution to replace the front fan, or the rear panel of the transmitter to replace the rear fan.
2. Switch off automatic line fuse F6 (rear fan) or F7 (front fan).
Note
Wait two minutes before starting to remove the fan (to allow for the fan overrun time).
3. Undo the four screws on the fan housing and remove the cover.
2099.9595.72
- 8.28 -
E-2
Chapter 8
Service
Fig. 18 Undoing the screws from the fan housing
4. On the upper side of the fan housing is a retaining device that must be unscrewed using
a Torx screwdriver No. 20.
Fig. 19 Unscrewing the retaining device
5. Pull the power cable out of the connector and take away the air tube.
2099.9595.72
- 8.29 -
E-2
Chapter 8
Service
6. Slide the fan slightly to the side, then pull it toward yourself and out of the fan housing.
The fan is easy to remove due to the guide rails
Fig. 20 Removing a fan
9.1.2
Installing the Fan
To install the unit in the transmitter, reverse the procedure used to remove it.
9.2
Replacing the Starting Capacitor
ATTENTION!
Always make sure that the power supply is disconnected before commencing any service
work on the transmitter rack; this will prevent injury caused by electric shock and damage
to the instruments.
9.2.1
Removing the Starting Capacitor
Note
Prior to removal make sure which of the two starting capacitors needs to be replaced.
2099.9595.72
- 8.30 -
E-2
Chapter 8
Service
1. Using a Torx screwdriver No. 20, remove the front panel of the power distribution to replace the front starting capacitor, or the rear panel of the transmitter to replace the rear
starting capacitor.
2. Switch off automatic line fuse F6 (fan 1, rear starting capacitor) or F7 (fan 2, front starting
capacitor).
3. Remove the fan connector.
4. Undo the nut (M8, wrench width 13 mm) on the face plate of the capacitor.
5. Cut off the cable ties to free the cable.
Fig. 21 Removing the starting capacitor
1)
2)
3)
4)
9.2.2
Connector (and socket)
Cable ties
Lock washer
Nut (M8)
Installing the Starting Capacitor
To install the unit in the transmitter, reverse the procedure used to remove it.
Note
The lock washer and M8 nut must be fastened together again.
9.3
Replacing the Differential Pressure Gage
ATTENTION!
Always make sure that the power supply is disconnected before commencing any service
work on the transmitter rack; this will prevent injury caused by electric shock and damage
to the instruments.
2099.9595.72
- 8.31 -
E-2
Chapter 8
Service
9.3.1
Removing the Differential Pressure Gage
Note
Prior to removal make sure which of the two differential pressure gages needs to be replaced.
1. Using a Torx screwdriver No. 20, remove the rear panel of the rack.
2. Remove the air connector (plastic tube).
3. Disconnect the associated cable from the connector on X45 of the power distribution
board. (Pins 1 and 2 for differential pressure gage 1 or pins 3 and 4 for differential pressure gage 2.)
4. Cut off the cable ties to free the cable.
5. Undo the two screws on the bracket.
6. Remove the differential pressure gage.
7. Unscrew the round cover and remove the cable (6.3 mm connector).
Fig. 22 Removing the differential pressure gage
9.3.2
Installing the Differential Pressure Gage
To install the unit in the transmitter, reverse the procedure used to remove it.
) Check whether the protective cap for the air nozzle on the left-hand differential pressure
gage has already been removed and if not, remove it (see figure).
2099.9595.72
- 8.32 -
E-2
Chapter 8
Service
Fig. 23 Differential pressure gage without protective cap
Note
After installation the differential pressure gage must be set to the switching point of 200 Pa
again.
1. Remove the transparent top cover.
In the middle is an adjuster with a scale.
2. Use a screwdriver to turn the adjuster until the arrow points to the value 200.
9.4
Replacing Temperature Sensors
ATTENTION!
Always make sure that the power supply is disconnected before commencing any service
work on the transmitter rack; this will prevent injury caused by electric shock and damage
to the instruments.
The transmitter rack contains two temperatur sensors which measure the intake and outlet
air temperatures. They are located on the intake and outlet lines on the rack.
9.4.1
Removing a Temperature Sensor
Note
Prior to removal make sure which of the two temperature sensors needs to be replaced.
1. Using a Torx screwdriver No. 20, remove the rear panel of the rack.
2. Unplug the connector of the temperature sensor concerned.
2099.9595.72
- 8.33 -
E-2
Chapter 8
Service
Fig. 24 Removing the temperature sensor
3. Using a Phillips screwdriver No. 0, undo the two screws (M3) on the temperature sensor
flange.
1) Openings for fixing screws (M3)
4. Carefully remove the temperature sensor from the aperture in the air duct.
9.4.2
Installing a Temperature Sensor
To install the unit in the transmitter, reverse the procedure used to remove it.
2099.9595.72
- 8.34 -
E-2
Chapter 8
Service
10
Transformer
Note
For more information about the transformer, refer to the manual on the optional AC supply
transformer.
2099.9595.72
- 8.35 -
E-2


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2007:11:02 12:39:40-04:00
Create Date                     : 2007:11:02 12:39:24-04:00
Title                           : 32 NV8202-26.04.06-01.00.book
Author                          : HUPFAUER
Creator                         : FrameMaker 7.0
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Page Count                      : 11
Mod Date                        : 2007:11:02 12:39:40-04:00
Creation Date                   : 2007:11:02 12:39:24-04:00
Metadata Date                   : 2007:11:02 12:39:40-04:00
Has XFA                         : No
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BQMNW8201E

Navigation menu