Acrodyne NW8201E DIGITAL TELEVISION BROADCAST TRANSMITTER User Manual 32 NV8202 26 04 06 01 00

Acrodyne Industries, Inc. DIGITAL TELEVISION BROADCAST TRANSMITTER 32 NV8202 26 04 06 01 00

Users Manual Part 20

Download: Acrodyne NW8201E DIGITAL TELEVISION BROADCAST TRANSMITTER User Manual 32 NV8202 26 04 06 01 00
Mirror Download [FCC.gov]Acrodyne NW8201E DIGITAL TELEVISION BROADCAST TRANSMITTER User Manual 32 NV8202 26 04 06 01 00
Document ID864585
Application IDvnwefxrVtvE1edbLlVsrmQ==
Document DescriptionUsers Manual Part 20
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize17.01kB (212670 bits)
Date Submitted2007-11-06 00:00:00
Date Available2008-01-18 00:00:00
Creation Date2007-11-02 12:40:12
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2007-11-02 12:40:36
Document Title32 NV8202-26.04.06-01.00.book
Document CreatorFrameMaker 7.0
Document Author: HUPFAUER

Broadcasting Division
CHAPTER 9
ANNEX
Printed in Germany
2095.7346.32
- 9.0 -
E-1
Broadcasting Division
Interface Description
TRANSMITTER
Printed in Germany
2098.1190.72
- 9.A -
E-1
Chapter 9
Annex
CONTENTS
1 Interface Description ....................................................................... 1
1.1 Front-Panel Interfaces ....................................................................................1
1.1.1 Q1 - AC Supply Input / Protective Earth .......................................................1
1.1.2 X57 - Optional Connector Kit ZR800Z1 ........................................................1
1.1.3 X33 - External Fan (Optional): (Wago Plug-In Terminal) .............................1
1.1.4 X33 - External Absorber Cooling (Optional): (Wago Plug-In Terminal) ........2
1.1.5 X41 - RF Loop: (Wago Plug-In Terminal) .....................................................2
1.1.6 X42 - Absorber Monitoring: (Wago Plug-In Terminal) ..................................3
1.1.7 X43 - Absorber Monitoring: (Wago Plug-In Terminal) ..................................3
1.1.8 X44 - Overcurrent Monitoring for External Fan: (Wago Plug-In Terminal) ...3
1.1.9 X100A - Ethernet A Remote (Standard): (8-Pin Socket) ..............................4
1.1.10 X100B - Ethernet B Remote (Option N+1): (8-Pin Socket) ..........................4
1.1.11 X232 RS232: (9-Pin D-Sub Socket) .............................................................5
1.1.12 X101A - CAN Bus Rack Bus A: (9-Pin D-Sub Socket) .................................5
1.1.13 X101B - CAN Bus Rack Bus B: (9-Pin D-Sub Socket) .................................5
1.1.14 X101C - CAN Bus Rack Bus C - Ext. Pump: (9-Pin D-Sub Socket) .............6
1.1.15 X102A - ANTENNA 1: (N Socket, 50 Ohm) .................................................7
1.1.16 X102B - ANTENNA 2: (N Socket, 50 Ohm) .................................................7
1.2 Interfaces on Transmitter Top .......................................................................7
1.2.1 X121A - TS1 Exciter A: (BNC Socket, 75 Ohm) ...........................................7
1.2.2 X121B - TS1 Exciter B: (BNC Socket, 75 Ohm) ...........................................7
1.2.3 X122A - TS2 Exciter A: (BNC Socket, 75 Ohm) ...........................................8
1.2.4 X122B - TS2 Exciter B: (BNC Socket, 75 Ohm) ...........................................8
1.2.5 X123A - TS3 Exciter A: (BNC Socket, 75 Ohm) ...........................................8
1.2.6 X123B - TS3 Exciter B: (BNC Socket, 75 Ohm) ...........................................8
1.2.7 X124A - TS4 Exciter A: (BNC Socket, 75 Ohm) ...........................................8
1.2.8 X124B - TS4 Exciter B: (BNC Socket, 75 Ohm) ...........................................9
1.2.9 X131A - TS1/2 IN Monitoring Exciter A: (BNC Socket) ................................9
1.2.10 X131B - TS1/2 IN Monitoring Exciter B: (BNC Socket) ................................9
1.2.11 X132A - TS3/4 IN Monitoring Exciter A: (BNC Socket) ................................9
1.2.12 X132B - TS3/4 IN Monitoring Exciter B: (BNC Socket) ..............................10
1.2.13 X141A - 1PPS Exciter A: (BNC Socket, 50 Ohm) ......................................10
1.2.14 X141B - 1PPS Exciter B: (BNC Socket, 50 Ohm) ......................................10
1.2.15 X142A - 1PPS Monitoring Exciter A: (BNC Socket, 50 Ohm) ....................10
2098.0594.72
- 9.01 -
E-1
Chapter 9
Annex
1.2.16 X142B- 1PPS Monitoring Exciter B: (BNC Socket, 50 Ohm) .....................11
1.2.17 X143A - 10MHz REF.INPUT Exciter A: (BNC Socket, 50 Ohm) ................11
1.2.18 X143B - 10MHz REF.INPUT Exciter B: (BNC Socket, 50 Ohm) ................11
1.2.19 RF Transmitter Output: (EIA 1 5/8", Flange 50 Ohm) ................................11
2099.9595.72
- 9.02 -
E-1
Chapter 9
Annex
Interface Description
1.1
Front-Panel Interfaces
1.1.1
Q1 - AC Supply Input / Protective Earth
1.1.2
1.1.3
2099.9595.72
Signal name
Direction
Value range
Contact
Remark
PHASE L1
Input
400 V ±15%
Q1.T1
Three-phase current input L1
PHASE L2
Input
400 V ±15%
Q1.T2
Three-phase current input L2
PHASE L3
Input
400 V ±15%
Q1.T3
Three-phase current input L1
NEUTRAL N
Input
0V
Q1.N
Neutral-conductor input N
PROTECTION
EARTH PE
Input
0V
X.PE
PE terminal
PROTECTION
EARTH PE
Input
0V
PE pin
PE station
X57 - Optional Connector Kit ZR800Z1
Signal name
Direction
Value range
Contact
Remark
PHASE L1
Input
230 V
X57.L1
Separate circuit
NEUTRAL N
Input
0V
X57.N
PROTECTION
EARTH PE
Input
0V
X57.PE
X33 - External Fan (Optional): (Wago Plug-In Terminal)
Signal name
Direction
Value range
Contact
Remark
PHASE L1
Input
230 V
X33.1
Line protection F8 [3A]
NEUTRAL N
Input
0V
X33.2
- 9.1 -
E-1
Chapter 9
Annex
Signal name
Direction
Value range
Contact
PROTECTION
EARTH PE
Input
0V
X33.3
Remark
External fan for dummy antenna (optional): (Wago plug-in terminal)
1.1.4
1.1.5
2099.9595.72
Signal name
Direction
Value range
Contact
Remark
PHASE L1
Input
230 V
X33.4
Line protection F8 [3A]
NEUTRAL N
Input
0V
X33.5
PROTECTION
EARTH PE
Input
0V
X33.6
X33 - External Absorber Cooling (Optional): (Wago Plug-In
Terminal)
Signal name
Direction
Value range
Contact
Remark
PHASE L1
Input
230 V
X34.1
Line protection F8 [3A]
NEUTRAL N
Input
0V
X34.2
PROTECTION
EARTH PE
Input
0V
X34.3
X41 - RF Loop: (Wago Plug-In Terminal)
Signal name
Direction
Value range
Contact
Remark
MAIN TX LOOP
Input
-12 V ±2 V
X41.1
-12 V floating
LOOP COM (+)
Output
+12 V ±2 V
X41.2
+12 V floating
RESERVE TX
LOOP
Input
-12 V ±2 V
X41.3
-12 V floating
LOOP COM (+)
Output
+12 V ±2 V
X41.4
+12 V floating
- 9.2 -
E-1
Chapter 9
1.1.6
1.1.7
1.1.8
2099.9595.72
Annex
X42 - Absorber Monitoring: (Wago Plug-In Terminal)
Signal name
Direction
Value range
Contact
Remark
FAULT SYSTEM
ABSORBER
Input
TTL
X42.1
Jumper to 0 V
REF RACK
SIGNALS
Output
0V
X42.2
Reference 0 V
FAULT RACK
ABSORBER
Input
TTL
X42.3
Jumper to 0 V
REF RACK
SIGNALS
Output
0V
X42.4
Reference 0 V
X43 - Absorber Monitoring: (Wago Plug-In Terminal)
Signal name
Direction
Value range
Contact
Remark
FAULT
COOLING 2
Input
TTL
X43.1
Jumper to 0 V
REF RACK
COOLING
Input
0V
X43.2
Reference 0 V
FAULT
COOLING 1
Input
TTL
X43.3
Jumper to 0 V
REF RACK
SIGNALS
Input
0V
X43.4
Reference 0 V
WARNING
COOLING
Input
TTL
X43.5
Jumper to 0 V
REF RACK
SIGNALS
Input
0V
X43.6
Reference 0 V
X44 - Overcurrent Monitoring for External Fan: (Wago PlugIn Terminal)
Signal name
Direction
Value range
Contact
Remark
FAULT EXT:
COOLING
Input
TTL
X44.1
Jumper to 0 V
REF RACK
SIGNALS
Output
0V
X44.4
Reference 0 V
- 9.3 -
E-1
Chapter 9
1.1.9
X100A - Ethernet A Remote (Standard): (8-Pin Socket)
Signal name
Direction
Value range
Contact
Remark
TX+
Output
Ethernet
X100A.1
Transmitting line
TX-
Output
Ethernet
X100A.2
Transmitting line
RX+
Input
Ethernet
X100A.3
Receiving line
Bidirect.
75 Ω termination
X100A.4
Bidirect.
75 Ω termination
X100A.5
Input
Ethernet
X100A.6
Bidirect.
75 Ω termination
X100A.7
Bidirect.
75 Ω termination
X100A.8
RX-
1.1.10
Receiving line
X100B - Ethernet B Remote (Option N+1): (8-Pin Socket)
Signal name
Direction
Value range
Contact
Remark
TX+
Output
Ethernet
X100B.1
Transmitting line
TX-
Output
Ethernet
X100B.2
Transmitting line
RX+
Input
Ethernet
X100B.3
Receiving line
Bidirect.
75 Ω termination
X100B.4
Bidirect.
75 Ω termination
X100B.5
Input
Ethernet
X100B.6
Bidirect.
75 Ω termination
X100B.7
Bidirect.
75 Ω termination
X100B.8
RX-
2099.9595.72
Annex
- 9.4 -
Receiving line
E-1
Chapter 9
1.1.11
X232 RS232: (9-Pin D-Sub Socket)
Signal name
Direction
Value range
n.c.
2099.9595.72
Remark
X232.1
Transmitting line
Output
RS-232
X232.2
Transmitting line
RS232_RX
Input
RS-232
X232.3
Receiving line
GND
1.1.13
Contact
RS232_TX
n.c.
1.1.12
Annex
X232.4
Bidirect.
X232.5
n.c.
X232.6
n.c.
X232.7
n.c.
X232.8
X101A - CAN Bus Rack Bus A: (9-Pin D-Sub Socket)
Signal name
Direction
Value range
Contact
Remark
12V_RED
Bidirect.
12 V ±1 V
X101A.1
Redundant 12 V supply
RC_A_CAN_L
Bidirect.
CAN-Level
X101A.2
CAN bus signal
CAN_GND
Bidirect.
0V
X101A.3
CAN GND
12V_RED
Bidirect.
12 V ±1 V
X101A.4
Redundant 12 V supply
CAN_SHLD
Bidirect.
GND
X101A.5
Shield
GND
Bidirect.
GND
X101A.6
GND
RC_A_CAN_H
Bidirect.
CAN+Level
X101A.7
CAN bus signal
12V_ASI
Bidirect.
12 V ±1.5 V
X101A.8
CAN_V+
Bidirect.
12 V ±1 V
X101A.9
X101B - CAN Bus Rack Bus B: (9-Pin D-Sub Socket)
Signal name
Direction
Value range
Contact
Remark
12V_RED
Bidirect.
12 V ±1 V
X101B.1
Redundant 12 V supply
- 9.5 -
E-1
Chapter 9
1.1.14
2099.9595.72
Annex
Signal name
Direction
Value range
Contact
Remark
RC_A_CAN_L
Bidirect.
CAN-Level
X101B.2
CAN bus signal
CAN_GND
Bidirect.
0V
X101B.3
CAN GND
12V_RED
Bidirect.
12 V ±1 V
X101B.4
Redundant 12 V supply
CAN_SHLD
Bidirect.
GND
X101B.5
Shield
GND
Bidirect.
GND
X101B.6
GND
RC_A_CAN_H
Bidirect.
CAN+Level
X101B.7
CAN bus signal
12V_ASI
Bidirect.
12 V ±1.5 V
X101B.8
CAN_V+
Bidirect.
12 V ±1 V
X101B.9
X101C - CAN Bus Rack Bus C - Ext. Pump: (9-Pin D-Sub
Socket)
Signal name
Direction
Value range
Contact
Remark
RS232_RxD0
Input
RS232
X101C.1
Internal serial interface, rack
controller
C_CAN_L
Bidirect.
CAN-Level
X101C.2
CAN bus signal
CAN_GND
Bidirect.
0V
X101C.3
CAN GND
BOOT
Input
TTL
X101C.4
Bootstrap mode key for rack
controller
CAN_SHLD
Bidirect.
GND
X101C.5
Shield
GND
Bidirect.
GND
X101C.6
GND
C_CAN_H
Bidirect.
CAN+Level
X101C.7
CAN bus signal
RS232_TxD0
Output
RS232
X101C.8
Internal serial interface, rack
controller
CAN_V+
Bidirect.
12 V ±1.5 V
Imax = 0.1 A
X101C.9
Supply of external bus driver
component from pump control
- 9.6 -
E-1
Chapter 9
1.1.15
1.1.16
Annex
X102A - ANTENNA 1: (N Socket, 50 Ohm)
Signal name
Direction
ANTENNA 1
Input
GND
Bidirect.
Value range
0V
Contact
Remark
X102A.1
Only for DTV TX level
depending on application
X102A.2
X102B - ANTENNA 2: (N Socket, 50 Ohm)
Signal name
Direction
ANTENNA 2
Input
GND
Bidirect.
Value range
0V
Contact
Remark
X102B.1
Only for DTV TX level
depending on application
X102B.2
1.2
Interfaces on Transmitter Top
1.2.1
X121A - TS1 Exciter A: (BNC Socket, 75 Ohm)
1.2.2
2099.9595.72
Signal name
Direction
Value range
Contact
Remark
TS1
Input
ASI/SMPTE310M
X121A.1
TS1 Exciter A
GND
Bidirect.
X121A.2
GND/shield
X121B - TS1 Exciter B: (BNC Socket, 75 Ohm)
Signal name
Direction
Value range
Contact
Remark
TS1
Input
ASI/SMPTE310M
X121B.1
TS1 Exciter B
GND
Bidirect.
X121B.2
GND/shield
- 9.7 -
E-1
Chapter 9
1.2.3
1.2.4
1.2.5
1.2.6
1.2.7
2099.9595.72
Annex
X122A - TS2 Exciter A: (BNC Socket, 75 Ohm)
Signal name
Direction
Value range
Contact
Remark
TS2
Input
ASI/SMPTE310M
X122A.1
TS2 Exciter A
GND
Bidirect.
X122A.2
GND/shield
X122B - TS2 Exciter B: (BNC Socket, 75 Ohm)
Signal name
Direction
Value range
Contact
Remark
TS2
Input
ASI/SMPTE310M
X122B.1
TS2 Exciter B
GND
Bidirect.
X122B.2
GND/shield
X123A - TS3 Exciter A: (BNC Socket, 75 Ohm)
Signal name
Direction
Value range
Contact
Remark
TS3
Input
ASI/SMPTE310M
X123A.1
TS3 Exciter A
GND
Bidirect.
X123A.2
GND/shield
X123B - TS3 Exciter B: (BNC Socket, 75 Ohm)
Signal name
Direction
Value range
Contact
Remark
TS3
Input
ASI/SMPTE310M
X123B.1
TS3 Exciter B
GND
Bidirect.
X123B.2
GND/shield
X124A - TS4 Exciter A: (BNC Socket, 75 Ohm)
Signal name
Direction
Value range
Contact
Remark
TS4
Input
ASI/SMPTE310M
X124A.1
TS4 Exciter A
- 9.8 -
E-1
Chapter 9
1.2.8
1.2.9
Signal name
Direction
GND
Bidirect.
X124A.2
GND/shield
Direction
Value range
Contact
Remark
TS4
Input
ASI/SMPTE310M
X124B.1
TS4 Exciter B
GND
Bidirect.
X124B.2
GND/shield
X131A - TS1/2 IN Monitoring Exciter A: (BNC Socket)
Direction
Value range
Contact
Remark
TS1/2 IN
Monitoring
Output
ASI/SMPTE310M
X131A.1
TS1/2 Monitoring Exciter A
GND
Bidirect.
X131A.2
GND/shield
X131B - TS1/2 IN Monitoring Exciter B: (BNC Socket)
Direction
Value range
Contact
Remark
TS1/2 IN
Monitoring
Output
ASI/SMPTE310M
X131B.1
TS1/2 Monitoring Exciter B
GND
Bidirect.
X131B.2
GND/shield
X132A - TS3/4 IN Monitoring Exciter A: (BNC Socket)
Signal
name
TS3/4 IN
Monitoring
2099.9595.72
Remark
Signal name
Signal
name
1.2.11
Contact
X124B - TS4 Exciter B: (BNC Socket, 75 Ohm)
Signal
name
1.2.10
Value range
Annex
Direction
Value range
Contact
Remark
Output
ASI/SMPTE310M
X132A.1
TS3/4 Monitoring Exciter A
- 9.9 -
E-1
Chapter 9
1.2.12
Signal
name
Direction
GND
Bidirect.
1.2.14
1.2.15
2099.9595.72
Contact
Remark
X132A.2
GND/shield
X132B - TS3/4 IN Monitoring Exciter B: (BNC Socket)
Signal
name
1.2.13
Value range
Annex
Direction
Value range
Contact
Remark
TS3/4 IN
Monitoring
Output
ASI/SMPTE310M
X132B.1
TS3/4 Monitoring Exciter B
GND
Bidirect.
X132B.2
GND/shield
X141A - 1PPS Exciter A: (BNC Socket, 50 Ohm)
Signal name
Direction
Value range
Contact
Remark
1PPS_EXTERN
Input
TTL level
(pos.edge)
X141A.1
Seconds pulse from external GPS receiver, exciter A
GND
Bidirect.
X141A.2
GND/shield
X141B - 1PPS Exciter B: (BNC Socket, 50 Ohm)
Signal name
Direction
Value range
Contact
Remark
1PPS_EXTERN
Input
TTL level
(pos.edge)
X141B.1
Seconds pulse from external GPS receiver, exciter B
GND
Bidirect.
X141B.2
GND/shield
X142A - 1PPS Monitoring Exciter A: (BNC Socket, 50 Ohm)
Signal name
Direction
Value range
Contact
Remark
1PPS Monitoring
Input
TTL level
(pos.edge)
X142A.1
Monitor output of internally
used 1PPS (exciter A)
- 9.10 -
E-1
Chapter 9
1.2.16
1.2.17
1.2.18
1.2.19
2099.9595.72
Signal name
Direction
GND
Bidirect.
Value range
Annex
Contact
Remark
X142A.2
GND/shield
X142B- 1PPS Monitoring Exciter B: (BNC Socket, 50 Ohm)
Signal name
Direction
Value range
Contact
Remark
1PPS Monitoring
Input
TTL level
(pos.edge)
X142B.1
Monitor output of internally
used 1PPS (exciter B)
GND
Bidirect.
X142B.2
GND/shield
X143A - 10MHz REF.INPUT Exciter A: (BNC Socket, 50 Ohm)
Signal name
Direction
Value range
Contact
Remark
10 MHz REF
INPUT
Input
-5.0 dB to 20 dBm
or TTL
X143A.1
10 MHz reference for
exciter A
GND
Bidirect.
X142A.2
GND/shield
X143B - 10MHz REF.INPUT Exciter B: (BNC Socket, 50 Ohm)
Signal name
Direction
Value range
Contact
Remark
10 MHz REF
INPUT
Input
-5.0 dB to 20 dBm
or TTL
X143B.1
10 MHz reference for
exciter B
GND
Bidirect.
X142B.2
GND/shield
RF Transmitter Output: (EIA 1 5/8", Flange 50 Ohm)
Signal name
Direction
Value range
Contact
Remark
RF transmitter
output
Output
PmaxAVG = 1950 W
RF
RF transmitter output
GND
Bidirect.
RF
GND/shield
- 9.11 -
E-1
Broadcasting Division
Drawings and Diagrams
TRANSMITTER
Printed in Germany
2098.1190.72
- 9.B -
E-1
Broadcasting Division
Spare Parts Lists
TRANSMITTER
Printed in Germany
2098.1190.72
- 9.C -
E-1


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2007:11:02 12:40:36-04:00
Create Date                     : 2007:11:02 12:40:12-04:00
Title                           : 32 NV8202-26.04.06-01.00.book
Author                          : HUPFAUER
Creator                         : FrameMaker 7.0
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Page Count                      : 22
Mod Date                        : 2007:11:02 12:40:36-04:00
Creation Date                   : 2007:11:02 12:40:12-04:00
Metadata Date                   : 2007:11:02 12:40:36-04:00
Has XFA                         : No
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BQMNW8201E

Navigation menu