Acrodyne NW8201E DIGITAL TELEVISION BROADCAST TRANSMITTER User Manual 32 NV8202 26 04 06 01 00
Acrodyne Industries, Inc. DIGITAL TELEVISION BROADCAST TRANSMITTER 32 NV8202 26 04 06 01 00
Acrodyne >
Contents
- 1. Users Manual Part 1
- 2. Users Manual Part 2
- 3. Users Manual Part 3
- 4. Users Manual Part 4
- 5. Users Manual Part 5
- 6. Users Manual Part 6
- 7. Users Manual Part 7
- 8. Users Manual Part 8
- 9. Users Manual Part 9
- 10. Users Manual Part 10
- 11. Users Manual Part 11
- 12. USers Manual Part 12
- 13. Users Manual Part 13
- 14. Users Manual Part 14
- 15. Users Manual Part 15
- 16. Users Manual Part 16
- 17. Users Manual Part 17
- 18. Users Manual Part 18
- 19. Users Manual Part 19
- 20. Users Manual Part 20
Users Manual Part 20
Broadcasting Division CHAPTER 9 ANNEX Printed in Germany 2095.7346.32 - 9.0 - E-1 Broadcasting Division Interface Description TRANSMITTER Printed in Germany 2098.1190.72 - 9.A - E-1 Chapter 9 Annex CONTENTS 1 Interface Description ....................................................................... 1 1.1 Front-Panel Interfaces ....................................................................................1 1.1.1 Q1 - AC Supply Input / Protective Earth .......................................................1 1.1.2 X57 - Optional Connector Kit ZR800Z1 ........................................................1 1.1.3 X33 - External Fan (Optional): (Wago Plug-In Terminal) .............................1 1.1.4 X33 - External Absorber Cooling (Optional): (Wago Plug-In Terminal) ........2 1.1.5 X41 - RF Loop: (Wago Plug-In Terminal) .....................................................2 1.1.6 X42 - Absorber Monitoring: (Wago Plug-In Terminal) ..................................3 1.1.7 X43 - Absorber Monitoring: (Wago Plug-In Terminal) ..................................3 1.1.8 X44 - Overcurrent Monitoring for External Fan: (Wago Plug-In Terminal) ...3 1.1.9 X100A - Ethernet A Remote (Standard): (8-Pin Socket) ..............................4 1.1.10 X100B - Ethernet B Remote (Option N+1): (8-Pin Socket) ..........................4 1.1.11 X232 RS232: (9-Pin D-Sub Socket) .............................................................5 1.1.12 X101A - CAN Bus Rack Bus A: (9-Pin D-Sub Socket) .................................5 1.1.13 X101B - CAN Bus Rack Bus B: (9-Pin D-Sub Socket) .................................5 1.1.14 X101C - CAN Bus Rack Bus C - Ext. Pump: (9-Pin D-Sub Socket) .............6 1.1.15 X102A - ANTENNA 1: (N Socket, 50 Ohm) .................................................7 1.1.16 X102B - ANTENNA 2: (N Socket, 50 Ohm) .................................................7 1.2 Interfaces on Transmitter Top .......................................................................7 1.2.1 X121A - TS1 Exciter A: (BNC Socket, 75 Ohm) ...........................................7 1.2.2 X121B - TS1 Exciter B: (BNC Socket, 75 Ohm) ...........................................7 1.2.3 X122A - TS2 Exciter A: (BNC Socket, 75 Ohm) ...........................................8 1.2.4 X122B - TS2 Exciter B: (BNC Socket, 75 Ohm) ...........................................8 1.2.5 X123A - TS3 Exciter A: (BNC Socket, 75 Ohm) ...........................................8 1.2.6 X123B - TS3 Exciter B: (BNC Socket, 75 Ohm) ...........................................8 1.2.7 X124A - TS4 Exciter A: (BNC Socket, 75 Ohm) ...........................................8 1.2.8 X124B - TS4 Exciter B: (BNC Socket, 75 Ohm) ...........................................9 1.2.9 X131A - TS1/2 IN Monitoring Exciter A: (BNC Socket) ................................9 1.2.10 X131B - TS1/2 IN Monitoring Exciter B: (BNC Socket) ................................9 1.2.11 X132A - TS3/4 IN Monitoring Exciter A: (BNC Socket) ................................9 1.2.12 X132B - TS3/4 IN Monitoring Exciter B: (BNC Socket) ..............................10 1.2.13 X141A - 1PPS Exciter A: (BNC Socket, 50 Ohm) ......................................10 1.2.14 X141B - 1PPS Exciter B: (BNC Socket, 50 Ohm) ......................................10 1.2.15 X142A - 1PPS Monitoring Exciter A: (BNC Socket, 50 Ohm) ....................10 2098.0594.72 - 9.01 - E-1 Chapter 9 Annex 1.2.16 X142B- 1PPS Monitoring Exciter B: (BNC Socket, 50 Ohm) .....................11 1.2.17 X143A - 10MHz REF.INPUT Exciter A: (BNC Socket, 50 Ohm) ................11 1.2.18 X143B - 10MHz REF.INPUT Exciter B: (BNC Socket, 50 Ohm) ................11 1.2.19 RF Transmitter Output: (EIA 1 5/8", Flange 50 Ohm) ................................11 2099.9595.72 - 9.02 - E-1 Chapter 9 Annex Interface Description 1.1 Front-Panel Interfaces 1.1.1 Q1 - AC Supply Input / Protective Earth 1.1.2 1.1.3 2099.9595.72 Signal name Direction Value range Contact Remark PHASE L1 Input 400 V ±15% Q1.T1 Three-phase current input L1 PHASE L2 Input 400 V ±15% Q1.T2 Three-phase current input L2 PHASE L3 Input 400 V ±15% Q1.T3 Three-phase current input L1 NEUTRAL N Input 0V Q1.N Neutral-conductor input N PROTECTION EARTH PE Input 0V X.PE PE terminal PROTECTION EARTH PE Input 0V PE pin PE station X57 - Optional Connector Kit ZR800Z1 Signal name Direction Value range Contact Remark PHASE L1 Input 230 V X57.L1 Separate circuit NEUTRAL N Input 0V X57.N PROTECTION EARTH PE Input 0V X57.PE X33 - External Fan (Optional): (Wago Plug-In Terminal) Signal name Direction Value range Contact Remark PHASE L1 Input 230 V X33.1 Line protection F8 [3A] NEUTRAL N Input 0V X33.2 - 9.1 - E-1 Chapter 9 Annex Signal name Direction Value range Contact PROTECTION EARTH PE Input 0V X33.3 Remark External fan for dummy antenna (optional): (Wago plug-in terminal) 1.1.4 1.1.5 2099.9595.72 Signal name Direction Value range Contact Remark PHASE L1 Input 230 V X33.4 Line protection F8 [3A] NEUTRAL N Input 0V X33.5 PROTECTION EARTH PE Input 0V X33.6 X33 - External Absorber Cooling (Optional): (Wago Plug-In Terminal) Signal name Direction Value range Contact Remark PHASE L1 Input 230 V X34.1 Line protection F8 [3A] NEUTRAL N Input 0V X34.2 PROTECTION EARTH PE Input 0V X34.3 X41 - RF Loop: (Wago Plug-In Terminal) Signal name Direction Value range Contact Remark MAIN TX LOOP Input -12 V ±2 V X41.1 -12 V floating LOOP COM (+) Output +12 V ±2 V X41.2 +12 V floating RESERVE TX LOOP Input -12 V ±2 V X41.3 -12 V floating LOOP COM (+) Output +12 V ±2 V X41.4 +12 V floating - 9.2 - E-1 Chapter 9 1.1.6 1.1.7 1.1.8 2099.9595.72 Annex X42 - Absorber Monitoring: (Wago Plug-In Terminal) Signal name Direction Value range Contact Remark FAULT SYSTEM ABSORBER Input TTL X42.1 Jumper to 0 V REF RACK SIGNALS Output 0V X42.2 Reference 0 V FAULT RACK ABSORBER Input TTL X42.3 Jumper to 0 V REF RACK SIGNALS Output 0V X42.4 Reference 0 V X43 - Absorber Monitoring: (Wago Plug-In Terminal) Signal name Direction Value range Contact Remark FAULT COOLING 2 Input TTL X43.1 Jumper to 0 V REF RACK COOLING Input 0V X43.2 Reference 0 V FAULT COOLING 1 Input TTL X43.3 Jumper to 0 V REF RACK SIGNALS Input 0V X43.4 Reference 0 V WARNING COOLING Input TTL X43.5 Jumper to 0 V REF RACK SIGNALS Input 0V X43.6 Reference 0 V X44 - Overcurrent Monitoring for External Fan: (Wago PlugIn Terminal) Signal name Direction Value range Contact Remark FAULT EXT: COOLING Input TTL X44.1 Jumper to 0 V REF RACK SIGNALS Output 0V X44.4 Reference 0 V - 9.3 - E-1 Chapter 9 1.1.9 X100A - Ethernet A Remote (Standard): (8-Pin Socket) Signal name Direction Value range Contact Remark TX+ Output Ethernet X100A.1 Transmitting line TX- Output Ethernet X100A.2 Transmitting line RX+ Input Ethernet X100A.3 Receiving line Bidirect. 75 Ω termination X100A.4 Bidirect. 75 Ω termination X100A.5 Input Ethernet X100A.6 Bidirect. 75 Ω termination X100A.7 Bidirect. 75 Ω termination X100A.8 RX- 1.1.10 Receiving line X100B - Ethernet B Remote (Option N+1): (8-Pin Socket) Signal name Direction Value range Contact Remark TX+ Output Ethernet X100B.1 Transmitting line TX- Output Ethernet X100B.2 Transmitting line RX+ Input Ethernet X100B.3 Receiving line Bidirect. 75 Ω termination X100B.4 Bidirect. 75 Ω termination X100B.5 Input Ethernet X100B.6 Bidirect. 75 Ω termination X100B.7 Bidirect. 75 Ω termination X100B.8 RX- 2099.9595.72 Annex - 9.4 - Receiving line E-1 Chapter 9 1.1.11 X232 RS232: (9-Pin D-Sub Socket) Signal name Direction Value range n.c. 2099.9595.72 Remark X232.1 Transmitting line Output RS-232 X232.2 Transmitting line RS232_RX Input RS-232 X232.3 Receiving line GND 1.1.13 Contact RS232_TX n.c. 1.1.12 Annex X232.4 Bidirect. X232.5 n.c. X232.6 n.c. X232.7 n.c. X232.8 X101A - CAN Bus Rack Bus A: (9-Pin D-Sub Socket) Signal name Direction Value range Contact Remark 12V_RED Bidirect. 12 V ±1 V X101A.1 Redundant 12 V supply RC_A_CAN_L Bidirect. CAN-Level X101A.2 CAN bus signal CAN_GND Bidirect. 0V X101A.3 CAN GND 12V_RED Bidirect. 12 V ±1 V X101A.4 Redundant 12 V supply CAN_SHLD Bidirect. GND X101A.5 Shield GND Bidirect. GND X101A.6 GND RC_A_CAN_H Bidirect. CAN+Level X101A.7 CAN bus signal 12V_ASI Bidirect. 12 V ±1.5 V X101A.8 CAN_V+ Bidirect. 12 V ±1 V X101A.9 X101B - CAN Bus Rack Bus B: (9-Pin D-Sub Socket) Signal name Direction Value range Contact Remark 12V_RED Bidirect. 12 V ±1 V X101B.1 Redundant 12 V supply - 9.5 - E-1 Chapter 9 1.1.14 2099.9595.72 Annex Signal name Direction Value range Contact Remark RC_A_CAN_L Bidirect. CAN-Level X101B.2 CAN bus signal CAN_GND Bidirect. 0V X101B.3 CAN GND 12V_RED Bidirect. 12 V ±1 V X101B.4 Redundant 12 V supply CAN_SHLD Bidirect. GND X101B.5 Shield GND Bidirect. GND X101B.6 GND RC_A_CAN_H Bidirect. CAN+Level X101B.7 CAN bus signal 12V_ASI Bidirect. 12 V ±1.5 V X101B.8 CAN_V+ Bidirect. 12 V ±1 V X101B.9 X101C - CAN Bus Rack Bus C - Ext. Pump: (9-Pin D-Sub Socket) Signal name Direction Value range Contact Remark RS232_RxD0 Input RS232 X101C.1 Internal serial interface, rack controller C_CAN_L Bidirect. CAN-Level X101C.2 CAN bus signal CAN_GND Bidirect. 0V X101C.3 CAN GND BOOT Input TTL X101C.4 Bootstrap mode key for rack controller CAN_SHLD Bidirect. GND X101C.5 Shield GND Bidirect. GND X101C.6 GND C_CAN_H Bidirect. CAN+Level X101C.7 CAN bus signal RS232_TxD0 Output RS232 X101C.8 Internal serial interface, rack controller CAN_V+ Bidirect. 12 V ±1.5 V Imax = 0.1 A X101C.9 Supply of external bus driver component from pump control - 9.6 - E-1 Chapter 9 1.1.15 1.1.16 Annex X102A - ANTENNA 1: (N Socket, 50 Ohm) Signal name Direction ANTENNA 1 Input GND Bidirect. Value range 0V Contact Remark X102A.1 Only for DTV TX level depending on application X102A.2 X102B - ANTENNA 2: (N Socket, 50 Ohm) Signal name Direction ANTENNA 2 Input GND Bidirect. Value range 0V Contact Remark X102B.1 Only for DTV TX level depending on application X102B.2 1.2 Interfaces on Transmitter Top 1.2.1 X121A - TS1 Exciter A: (BNC Socket, 75 Ohm) 1.2.2 2099.9595.72 Signal name Direction Value range Contact Remark TS1 Input ASI/SMPTE310M X121A.1 TS1 Exciter A GND Bidirect. X121A.2 GND/shield X121B - TS1 Exciter B: (BNC Socket, 75 Ohm) Signal name Direction Value range Contact Remark TS1 Input ASI/SMPTE310M X121B.1 TS1 Exciter B GND Bidirect. X121B.2 GND/shield - 9.7 - E-1 Chapter 9 1.2.3 1.2.4 1.2.5 1.2.6 1.2.7 2099.9595.72 Annex X122A - TS2 Exciter A: (BNC Socket, 75 Ohm) Signal name Direction Value range Contact Remark TS2 Input ASI/SMPTE310M X122A.1 TS2 Exciter A GND Bidirect. X122A.2 GND/shield X122B - TS2 Exciter B: (BNC Socket, 75 Ohm) Signal name Direction Value range Contact Remark TS2 Input ASI/SMPTE310M X122B.1 TS2 Exciter B GND Bidirect. X122B.2 GND/shield X123A - TS3 Exciter A: (BNC Socket, 75 Ohm) Signal name Direction Value range Contact Remark TS3 Input ASI/SMPTE310M X123A.1 TS3 Exciter A GND Bidirect. X123A.2 GND/shield X123B - TS3 Exciter B: (BNC Socket, 75 Ohm) Signal name Direction Value range Contact Remark TS3 Input ASI/SMPTE310M X123B.1 TS3 Exciter B GND Bidirect. X123B.2 GND/shield X124A - TS4 Exciter A: (BNC Socket, 75 Ohm) Signal name Direction Value range Contact Remark TS4 Input ASI/SMPTE310M X124A.1 TS4 Exciter A - 9.8 - E-1 Chapter 9 1.2.8 1.2.9 Signal name Direction GND Bidirect. X124A.2 GND/shield Direction Value range Contact Remark TS4 Input ASI/SMPTE310M X124B.1 TS4 Exciter B GND Bidirect. X124B.2 GND/shield X131A - TS1/2 IN Monitoring Exciter A: (BNC Socket) Direction Value range Contact Remark TS1/2 IN Monitoring Output ASI/SMPTE310M X131A.1 TS1/2 Monitoring Exciter A GND Bidirect. X131A.2 GND/shield X131B - TS1/2 IN Monitoring Exciter B: (BNC Socket) Direction Value range Contact Remark TS1/2 IN Monitoring Output ASI/SMPTE310M X131B.1 TS1/2 Monitoring Exciter B GND Bidirect. X131B.2 GND/shield X132A - TS3/4 IN Monitoring Exciter A: (BNC Socket) Signal name TS3/4 IN Monitoring 2099.9595.72 Remark Signal name Signal name 1.2.11 Contact X124B - TS4 Exciter B: (BNC Socket, 75 Ohm) Signal name 1.2.10 Value range Annex Direction Value range Contact Remark Output ASI/SMPTE310M X132A.1 TS3/4 Monitoring Exciter A - 9.9 - E-1 Chapter 9 1.2.12 Signal name Direction GND Bidirect. 1.2.14 1.2.15 2099.9595.72 Contact Remark X132A.2 GND/shield X132B - TS3/4 IN Monitoring Exciter B: (BNC Socket) Signal name 1.2.13 Value range Annex Direction Value range Contact Remark TS3/4 IN Monitoring Output ASI/SMPTE310M X132B.1 TS3/4 Monitoring Exciter B GND Bidirect. X132B.2 GND/shield X141A - 1PPS Exciter A: (BNC Socket, 50 Ohm) Signal name Direction Value range Contact Remark 1PPS_EXTERN Input TTL level (pos.edge) X141A.1 Seconds pulse from external GPS receiver, exciter A GND Bidirect. X141A.2 GND/shield X141B - 1PPS Exciter B: (BNC Socket, 50 Ohm) Signal name Direction Value range Contact Remark 1PPS_EXTERN Input TTL level (pos.edge) X141B.1 Seconds pulse from external GPS receiver, exciter B GND Bidirect. X141B.2 GND/shield X142A - 1PPS Monitoring Exciter A: (BNC Socket, 50 Ohm) Signal name Direction Value range Contact Remark 1PPS Monitoring Input TTL level (pos.edge) X142A.1 Monitor output of internally used 1PPS (exciter A) - 9.10 - E-1 Chapter 9 1.2.16 1.2.17 1.2.18 1.2.19 2099.9595.72 Signal name Direction GND Bidirect. Value range Annex Contact Remark X142A.2 GND/shield X142B- 1PPS Monitoring Exciter B: (BNC Socket, 50 Ohm) Signal name Direction Value range Contact Remark 1PPS Monitoring Input TTL level (pos.edge) X142B.1 Monitor output of internally used 1PPS (exciter B) GND Bidirect. X142B.2 GND/shield X143A - 10MHz REF.INPUT Exciter A: (BNC Socket, 50 Ohm) Signal name Direction Value range Contact Remark 10 MHz REF INPUT Input -5.0 dB to 20 dBm or TTL X143A.1 10 MHz reference for exciter A GND Bidirect. X142A.2 GND/shield X143B - 10MHz REF.INPUT Exciter B: (BNC Socket, 50 Ohm) Signal name Direction Value range Contact Remark 10 MHz REF INPUT Input -5.0 dB to 20 dBm or TTL X143B.1 10 MHz reference for exciter B GND Bidirect. X142B.2 GND/shield RF Transmitter Output: (EIA 1 5/8", Flange 50 Ohm) Signal name Direction Value range Contact Remark RF transmitter output Output PmaxAVG = 1950 W RF RF transmitter output GND Bidirect. RF GND/shield - 9.11 - E-1 Broadcasting Division Drawings and Diagrams TRANSMITTER Printed in Germany 2098.1190.72 - 9.B - E-1 Broadcasting Division Spare Parts Lists TRANSMITTER Printed in Germany 2098.1190.72 - 9.C - E-1
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2007:11:02 12:40:36-04:00 Create Date : 2007:11:02 12:40:12-04:00 Title : 32 NV8202-26.04.06-01.00.book Author : HUPFAUER Creator : FrameMaker 7.0 Producer : Acrobat Distiller 5.0.5 (Windows) Page Count : 22 Mod Date : 2007:11:02 12:40:36-04:00 Creation Date : 2007:11:02 12:40:12-04:00 Metadata Date : 2007:11:02 12:40:36-04:00 Has XFA : NoEXIF Metadata provided by EXIF.tools