Acrodyne NW8201E DIGITAL TELEVISION BROADCAST TRANSMITTER User Manual 32 NV8202 26 04 06 01 00

Acrodyne Industries, Inc. DIGITAL TELEVISION BROADCAST TRANSMITTER 32 NV8202 26 04 06 01 00

Users Manual Part 20

Broadcasting Division
2095.7346.32 - 9.0 - E-1
CHAPTER 9
ANNEX
Printed in Germany
Broadcasting Division
2098.1190.72 - 9.A - E-1
Interface Description
TRANSMITTER
Printed in Germany
Chapter 9 Annex
2098.0594.72 - 9.01 - E-1
CONTENTS
1 Interface Description ....................................................................... 1
1.1 Front-Panel Interfaces ....................................................................................1
1.1.1 Q1 - AC Supply Input / Protective Earth .......................................................1
1.1.2 X57 - Optional Connector Kit ZR800Z1 ........................................................1
1.1.3 X33 - External Fan (Optional): (Wago Plug-In Terminal) .............................1
1.1.4 X33 - External Absorber Cooling (Optional): (Wago Plug-In Terminal) ........2
1.1.5 X41 - RF Loop: (Wago Plug-In Terminal) .....................................................2
1.1.6 X42 - Absorber Monitoring: (Wago Plug-In Terminal) ..................................3
1.1.7 X43 - Absorber Monitoring: (Wago Plug-In Terminal) ..................................3
1.1.8 X44 - Overcurrent Monitoring for External Fan: (Wago Plug-In Terminal) ...3
1.1.9 X100A - Ethernet A Remote (Standard): (8-Pin Socket) ..............................4
1.1.10 X100B - Ethernet B Remote (Option N+1): (8-Pin Socket) ..........................4
1.1.11 X232 RS232: (9-Pin D-Sub Socket) .............................................................5
1.1.12 X101A - CAN Bus Rack Bus A: (9-Pin D-Sub Socket) .................................5
1.1.13 X101B - CAN Bus Rack Bus B: (9-Pin D-Sub Socket) .................................5
1.1.14 X101C - CAN Bus Rack Bus C - Ext. Pump: (9-Pin D-Sub Socket) .............6
1.1.15 X102A - ANTENNA 1: (N Socket, 50 Ohm) .................................................7
1.1.16 X102B - ANTENNA 2: (N Socket, 50 Ohm) .................................................7
1.2 Interfaces on Transmitter Top .......................................................................7
1.2.1 X121A - TS1 Exciter A: (BNC Socket, 75 Ohm) ...........................................7
1.2.2 X121B - TS1 Exciter B: (BNC Socket, 75 Ohm) ...........................................7
1.2.3 X122A - TS2 Exciter A: (BNC Socket, 75 Ohm) ...........................................8
1.2.4 X122B - TS2 Exciter B: (BNC Socket, 75 Ohm) ...........................................8
1.2.5 X123A - TS3 Exciter A: (BNC Socket, 75 Ohm) ...........................................8
1.2.6 X123B - TS3 Exciter B: (BNC Socket, 75 Ohm) ...........................................8
1.2.7 X124A - TS4 Exciter A: (BNC Socket, 75 Ohm) ...........................................8
1.2.8 X124B - TS4 Exciter B: (BNC Socket, 75 Ohm) ...........................................9
1.2.9 X131A - TS1/2 IN Monitoring Exciter A: (BNC Socket) ................................9
1.2.10 X131B - TS1/2 IN Monitoring Exciter B: (BNC Socket) ................................9
1.2.11 X132A - TS3/4 IN Monitoring Exciter A: (BNC Socket) ................................9
1.2.12 X132B - TS3/4 IN Monitoring Exciter B: (BNC Socket) ..............................10
1.2.13 X141A - 1PPS Exciter A: (BNC Socket, 50 Ohm) ......................................10
1.2.14 X141B - 1PPS Exciter B: (BNC Socket, 50 Ohm) ......................................10
1.2.15 X142A - 1PPS Monitoring Exciter A: (BNC Socket, 50 Ohm) ....................10
Chapter 9 Annex
2099.9595.72 - 9.02 - E-1
1.2.16 X142B- 1PPS Monitoring Exciter B: (BNC Socket, 50 Ohm) .....................11
1.2.17 X143A - 10MHz REF.INPUT Exciter A: (BNC Socket, 50 Ohm) ................11
1.2.18 X143B - 10MHz REF.INPUT Exciter B: (BNC Socket, 50 Ohm) ................11
1.2.19 RF Transmitter Output: (EIA 1 5/8", Flange 50 Ohm) ................................11
Chapter 9 Annex
2099.9595.72 - 9.1 - E-1
1 Interface Description
1.1 Front-Panel Interfaces
1.1.1 Q1 - AC Supply Input / Protective Earth
1.1.2 X57 - Optional Connector Kit ZR800Z1
1.1.3 X33 - External Fan (Optional): (Wago Plug-In Terminal)
Signal name Direction Value range Contact Remark
PHASE L1 Input 400 V ±15% Q1.T1 Three-phase current input L1
PHASE L2 Input 400 V ±15% Q1.T2 Three-phase current input L2
PHASE L3 Input 400 V ±15% Q1.T3 Three-phase current input L1
NEUTRAL N Input 0 V Q1.N Neutral-conductor input N
PROTECTION
EARTH PE
Input 0 V X.PE PE terminal
PROTECTION
EARTH PE
Input 0 V PE pin PE station
Signal name Direction Value range Contact Remark
PHASE L1 Input 230 V X57.L1 Separate circuit
NEUTRAL N Input 0 V X57.N
PROTECTION
EARTH PE
Input 0 V X57.PE
Signal name Direction Value range Contact Remark
PHASE L1 Input 230 V X33.1 Line protection F8 [3A]
NEUTRAL N Input 0 V X33.2
Chapter 9 Annex
2099.9595.72 - 9.2 - E-1
External fan for dummy antenna (optional): (Wago plug-in terminal)
1.1.4 X33 - External Absorber Cooling (Optional): (Wago Plug-In
Terminal)
1.1.5 X41 - RF Loop: (Wago Plug-In Terminal)
PROTECTION
EARTH PE
Input 0 V X33.3
Signal name Direction Value range Contact Remark
PHASE L1 Input 230 V X33.4 Line protection F8 [3A]
NEUTRAL N Input 0 V X33.5
PROTECTION
EARTH PE
Input 0 V X33.6
Signal name Direction Value range Contact Remark
PHASE L1 Input 230 V X34.1 Line protection F8 [3A]
NEUTRAL N Input 0 V X34.2
PROTECTION
EARTH PE
Input 0 V X34.3
Signal name Direction Value range Contact Remark
MAIN TX LOOP Input -12 V ±2 V X41.1 -12 V floating
LOOP COM (+) Output +12 V ±2 V X41.2 +12 V floating
RESERVE TX
LOOP
Input -12 V ±2 V X41.3 -12 V floating
LOOP COM (+) Output +12 V ±2 V X41.4 +12 V floating
Signal name Direction Value range Contact Remark
Chapter 9 Annex
2099.9595.72 - 9.3 - E-1
1.1.6 X42 - Absorber Monitoring: (Wago Plug-In Terminal)
1.1.7 X43 - Absorber Monitoring: (Wago Plug-In Terminal)
1.1.8 X44 - Overcurrent Monitoring for External Fan: (Wago Plug-
In Terminal)
Signal name Direction Value range Contact Remark
FAULT SYSTEM
ABSORBER
Input TTL X42.1 Jumper to 0 V
REF RACK
SIGNALS
Output 0 V X42.2 Reference 0 V
FAULT RACK
ABSORBER
Input TTL X42.3 Jumper to 0 V
REF RACK
SIGNALS
Output 0 V X42.4 Reference 0 V
Signal name Direction Value range Contact Remark
FAULT
COOLING 2
Input TTL X43.1 Jumper to 0 V
REF RACK
COOLING
Input 0 V X43.2 Reference 0 V
FAULT
COOLING 1
Input TTL X43.3 Jumper to 0 V
REF RACK
SIGNALS
Input 0 V X43.4 Reference 0 V
WARNING
COOLING
Input TTL X43.5 Jumper to 0 V
REF RACK
SIGNALS
Input 0 V X43.6 Reference 0 V
Signal name Direction Value range Contact Remark
FAULT EXT:
COOLING
Input TTL X44.1 Jumper to 0 V
REF RACK
SIGNALS
Output 0 V X44.4 Reference 0 V
Chapter 9 Annex
2099.9595.72 - 9.4 - E-1
1.1.9 X100A - Ethernet A Remote (Standard): (8-Pin Socket)
1.1.10 X100B - Ethernet B Remote (Option N+1): (8-Pin Socket)
Signal name Direction Value range Contact Remark
TX+ Output Ethernet X100A.1 Transmitting line
TX- Output Ethernet X100A.2 Transmitting line
RX+ Input Ethernet X100A.3 Receiving line
Bidirect. 75 termina-
tion
X100A.4
Bidirect. 75 termina-
tion
X100A.5
RX- Input Ethernet X100A.6 Receiving line
Bidirect. 75 termina-
tion
X100A.7
Bidirect. 75 termina-
tion
X100A.8
Signal name Direction Value range Contact Remark
TX+ Output Ethernet X100B.1 Transmitting line
TX- Output Ethernet X100B.2 Transmitting line
RX+ Input Ethernet X100B.3 Receiving line
Bidirect. 75 termina-
tion
X100B.4
Bidirect. 75 termina-
tion
X100B.5
RX- Input Ethernet X100B.6 Receiving line
Bidirect. 75 termina-
tion
X100B.7
Bidirect. 75 termina-
tion
X100B.8
Chapter 9 Annex
2099.9595.72 - 9.5 - E-1
1.1.11 X232 RS232: (9-Pin D-Sub Socket)
1.1.12 X101A - CAN Bus Rack Bus A: (9-Pin D-Sub Socket)
1.1.13 X101B - CAN Bus Rack Bus B: (9-Pin D-Sub Socket)
Signal name Direction Value range Contact Remark
n.c. X232.1 Transmitting line
RS232_TX Output RS-232 X232.2 Transmitting line
RS232_RX Input RS-232 X232.3 Receiving line
n.c. X232.4
GND Bidirect. X232.5
n.c. X232.6
n.c. X232.7
n.c. X232.8
Signal name Direction Value range Contact Remark
12V_RED Bidirect. 12 V ±1 V X101A.1 Redundant 12 V supply
RC_A_CAN_L Bidirect. CAN-Level X101A.2 CAN bus signal
CAN_GND Bidirect. 0 V X101A.3 CAN GND
12V_RED Bidirect. 12 V ±1 V X101A.4 Redundant 12 V supply
CAN_SHLD Bidirect. GND X101A.5 Shield
GND Bidirect. GND X101A.6 GND
RC_A_CAN_H Bidirect. CAN+Level X101A.7 CAN bus signal
12V_ASI Bidirect. 12 V ±1.5 V X101A.8
CAN_V+ Bidirect. 12 V ±1 V X101A.9
Signal name Direction Value range Contact Remark
12V_RED Bidirect. 12 V ±1 V X101B.1 Redundant 12 V supply
Chapter 9 Annex
2099.9595.72 - 9.6 - E-1
1.1.14 X101C - CAN Bus Rack Bus C - Ext. Pump: (9-Pin D-Sub
Socket)
RC_A_CAN_L Bidirect. CAN-Level X101B.2 CAN bus signal
CAN_GND Bidirect. 0 V X101B.3 CAN GND
12V_RED Bidirect. 12 V ±1 V X101B.4 Redundant 12 V supply
CAN_SHLD Bidirect. GND X101B.5 Shield
GND Bidirect. GND X101B.6 GND
RC_A_CAN_H Bidirect. CAN+Level X101B.7 CAN bus signal
12V_ASI Bidirect. 12 V ±1.5 V X101B.8
CAN_V+ Bidirect. 12 V ±1 V X101B.9
Signal name Direction Value range Contact Remark
RS232_RxD0 Input RS232 X101C.1 Internal serial interface, rack
controller
C_CAN_L Bidirect. CAN-Level X101C.2 CAN bus signal
CAN_GND Bidirect. 0 V X101C.3 CAN GND
BOOT Input TTL X101C.4 Bootstrap mode key for rack
controller
CAN_SHLD Bidirect. GND X101C.5 Shield
GND Bidirect. GND X101C.6 GND
C_CAN_H Bidirect. CAN+Level X101C.7 CAN bus signal
RS232_TxD0 Output RS232 X101C.8 Internal serial interface, rack
controller
CAN_V+ Bidirect. 12 V ±1.5 V
Imax = 0.1 A
X101C.9 Supply of external bus driver
component from pump con-
trol
Signal name Direction Value range Contact Remark
Chapter 9 Annex
2099.9595.72 - 9.7 - E-1
1.1.15 X102A - ANTENNA 1: (N Socket, 50 Ohm)
1.1.16 X102B - ANTENNA 2: (N Socket, 50 Ohm)
1.2 Interfaces on Transmitter Top
1.2.1 X121A - TS1 Exciter A: (BNC Socket, 75 Ohm)
1.2.2 X121B - TS1 Exciter B: (BNC Socket, 75 Ohm)
Signal name Direction Value range Contact Remark
ANTENNA 1 Input X102A.1 Only for DTV TX level
depending on application
GND Bidirect. 0 V X102A.2
Signal name Direction Value range Contact Remark
ANTENNA 2 Input X102B.1 Only for DTV TX level
depending on application
GND Bidirect. 0 V X102B.2
Signal name Direction Value range Contact Remark
TS1 Input ASI/SMPTE310M X121A.1 TS1 Exciter A
GND Bidirect. X121A.2 GND/shield
Signal name Direction Value range Contact Remark
TS1 Input ASI/SMPTE310M X121B.1 TS1 Exciter B
GND Bidirect. X121B.2 GND/shield
Chapter 9 Annex
2099.9595.72 - 9.8 - E-1
1.2.3 X122A - TS2 Exciter A: (BNC Socket, 75 Ohm)
1.2.4 X122B - TS2 Exciter B: (BNC Socket, 75 Ohm)
1.2.5 X123A - TS3 Exciter A: (BNC Socket, 75 Ohm)
1.2.6 X123B - TS3 Exciter B: (BNC Socket, 75 Ohm)
1.2.7 X124A - TS4 Exciter A: (BNC Socket, 75 Ohm)
Signal name Direction Value range Contact Remark
TS2 Input ASI/SMPTE310M X122A.1 TS2 Exciter A
GND Bidirect. X122A.2 GND/shield
Signal name Direction Value range Contact Remark
TS2 Input ASI/SMPTE310M X122B.1 TS2 Exciter B
GND Bidirect. X122B.2 GND/shield
Signal name Direction Value range Contact Remark
TS3 Input ASI/SMPTE310M X123A.1 TS3 Exciter A
GND Bidirect. X123A.2 GND/shield
Signal name Direction Value range Contact Remark
TS3 Input ASI/SMPTE310M X123B.1 TS3 Exciter B
GND Bidirect. X123B.2 GND/shield
Signal name Direction Value range Contact Remark
TS4 Input ASI/SMPTE310M X124A.1 TS4 Exciter A
Chapter 9 Annex
2099.9595.72 - 9.9 - E-1
1.2.8 X124B - TS4 Exciter B: (BNC Socket, 75 Ohm)
1.2.9 X131A - TS1/2 IN Monitoring Exciter A: (BNC Socket)
1.2.10 X131B - TS1/2 IN Monitoring Exciter B: (BNC Socket)
1.2.11 X132A - TS3/4 IN Monitoring Exciter A: (BNC Socket)
GND Bidirect. X124A.2 GND/shield
Signal name Direction Value range Contact Remark
TS4 Input ASI/SMPTE310M X124B.1 TS4 Exciter B
GND Bidirect. X124B.2 GND/shield
Signal
name Direction Value range Contact Remark
TS1/2 IN
Monitoring
Output ASI/SMPTE310M X131A.1 TS1/2 Monitoring Exciter A
GND Bidirect. X131A.2 GND/shield
Signal
name Direction Value range Contact Remark
TS1/2 IN
Monitoring
Output ASI/SMPTE310M X131B.1 TS1/2 Monitoring Exciter B
GND Bidirect. X131B.2 GND/shield
Signal
name Direction Value range Contact Remark
TS3/4 IN
Monitoring
Output ASI/SMPTE310M X132A.1 TS3/4 Monitoring Exciter A
Signal name Direction Value range Contact Remark
Chapter 9 Annex
2099.9595.72 - 9.10 - E-1
1.2.12 X132B - TS3/4 IN Monitoring Exciter B: (BNC Socket)
1.2.13 X141A - 1PPS Exciter A: (BNC Socket, 50 Ohm)
1.2.14 X141B - 1PPS Exciter B: (BNC Socket, 50 Ohm)
1.2.15 X142A - 1PPS Monitoring Exciter A: (BNC Socket, 50 Ohm)
GND Bidirect. X132A.2 GND/shield
Signal
name Direction Value range Contact Remark
TS3/4 IN
Monitoring
Output ASI/SMPTE310M X132B.1 TS3/4 Monitoring Exciter B
GND Bidirect. X132B.2 GND/shield
Signal name Direction Value range Contact Remark
1PPS_EXTERN Input TTL level
(pos.edge)
X141A.1 Seconds pulse from exter-
nal GPS receiver, exciter A
GND Bidirect. X141A.2 GND/shield
Signal name Direction Value range Contact Remark
1PPS_EXTERN Input TTL level
(pos.edge)
X141B.1 Seconds pulse from exter-
nal GPS receiver, exciter B
GND Bidirect. X141B.2 GND/shield
Signal name Direction Value range Contact Remark
1PPS Monitor-
ing
Input TTL level
(pos.edge)
X142A.1 Monitor output of internally
used 1PPS (exciter A)
Signal
name Direction Value range Contact Remark
Chapter 9 Annex
2099.9595.72 - 9.11 - E-1
1.2.16 X142B- 1PPS Monitoring Exciter B: (BNC Socket, 50 Ohm)
1.2.17 X143A - 10MHz REF.INPUT Exciter A: (BNC Socket, 50 Ohm)
1.2.18 X143B - 10MHz REF.INPUT Exciter B: (BNC Socket, 50 Ohm)
1.2.19 RF Transmitter Output: (EIA 1 5/8", Flange 50 Ohm)
GND Bidirect. X142A.2 GND/shield
Signal name Direction Value range Contact Remark
1PPS Monitor-
ing
Input TTL level
(pos.edge)
X142B.1 Monitor output of internally
used 1PPS (exciter B)
GND Bidirect. X142B.2 GND/shield
Signal name Direction Value range Contact Remark
10 MHz REF
INPUT
Input -5.0 dB to 20 dBm
or TTL
X143A.1 10 MHz reference for
exciter A
GND Bidirect. X142A.2 GND/shield
Signal name Direction Value range Contact Remark
10 MHz REF
INPUT
Input -5.0 dB to 20 dBm
or TTL
X143B.1 10 MHz reference for
exciter B
GND Bidirect. X142B.2 GND/shield
Signal name Direction Value range Contact Remark
RF transmitter
output
Output PmaxAVG = 1950 W RF RF transmitter output
GND Bidirect. RF GND/shield
Signal name Direction Value range Contact Remark
Broadcasting Division
2098.1190.72 - 9.B - E-1
Drawings and Diagrams
TRANSMITTER
Printed in Germany
Broadcasting Division
2098.1190.72 - 9.C - E-1
Spare Parts Lists
TRANSMITTER
Printed in Germany

Navigation menu