Acrodyne NW8201E DIGITAL TELEVISION BROADCAST TRANSMITTER User Manual 32 NV8202 26 04 06 01 00
Acrodyne Industries, Inc. DIGITAL TELEVISION BROADCAST TRANSMITTER 32 NV8202 26 04 06 01 00
Acrodyne >
Contents
- 1. Users Manual Part 1
- 2. Users Manual Part 2
- 3. Users Manual Part 3
- 4. Users Manual Part 4
- 5. Users Manual Part 5
- 6. Users Manual Part 6
- 7. Users Manual Part 7
- 8. Users Manual Part 8
- 9. Users Manual Part 9
- 10. Users Manual Part 10
- 11. Users Manual Part 11
- 12. USers Manual Part 12
- 13. Users Manual Part 13
- 14. Users Manual Part 14
- 15. Users Manual Part 15
- 16. Users Manual Part 16
- 17. Users Manual Part 17
- 18. Users Manual Part 18
- 19. Users Manual Part 19
- 20. Users Manual Part 20
Users Manual Part 20

Broadcasting Division
2095.7346.32 - 9.0 - E-1
CHAPTER 9
ANNEX
Printed in Germany

Broadcasting Division
2098.1190.72 - 9.A - E-1
Interface Description
TRANSMITTER
Printed in Germany

Chapter 9 Annex
2098.0594.72 - 9.01 - E-1
CONTENTS
1 Interface Description ....................................................................... 1
1.1 Front-Panel Interfaces ....................................................................................1
1.1.1 Q1 - AC Supply Input / Protective Earth .......................................................1
1.1.2 X57 - Optional Connector Kit ZR800Z1 ........................................................1
1.1.3 X33 - External Fan (Optional): (Wago Plug-In Terminal) .............................1
1.1.4 X33 - External Absorber Cooling (Optional): (Wago Plug-In Terminal) ........2
1.1.5 X41 - RF Loop: (Wago Plug-In Terminal) .....................................................2
1.1.6 X42 - Absorber Monitoring: (Wago Plug-In Terminal) ..................................3
1.1.7 X43 - Absorber Monitoring: (Wago Plug-In Terminal) ..................................3
1.1.8 X44 - Overcurrent Monitoring for External Fan: (Wago Plug-In Terminal) ...3
1.1.9 X100A - Ethernet A Remote (Standard): (8-Pin Socket) ..............................4
1.1.10 X100B - Ethernet B Remote (Option N+1): (8-Pin Socket) ..........................4
1.1.11 X232 RS232: (9-Pin D-Sub Socket) .............................................................5
1.1.12 X101A - CAN Bus Rack Bus A: (9-Pin D-Sub Socket) .................................5
1.1.13 X101B - CAN Bus Rack Bus B: (9-Pin D-Sub Socket) .................................5
1.1.14 X101C - CAN Bus Rack Bus C - Ext. Pump: (9-Pin D-Sub Socket) .............6
1.1.15 X102A - ANTENNA 1: (N Socket, 50 Ohm) .................................................7
1.1.16 X102B - ANTENNA 2: (N Socket, 50 Ohm) .................................................7
1.2 Interfaces on Transmitter Top .......................................................................7
1.2.1 X121A - TS1 Exciter A: (BNC Socket, 75 Ohm) ...........................................7
1.2.2 X121B - TS1 Exciter B: (BNC Socket, 75 Ohm) ...........................................7
1.2.3 X122A - TS2 Exciter A: (BNC Socket, 75 Ohm) ...........................................8
1.2.4 X122B - TS2 Exciter B: (BNC Socket, 75 Ohm) ...........................................8
1.2.5 X123A - TS3 Exciter A: (BNC Socket, 75 Ohm) ...........................................8
1.2.6 X123B - TS3 Exciter B: (BNC Socket, 75 Ohm) ...........................................8
1.2.7 X124A - TS4 Exciter A: (BNC Socket, 75 Ohm) ...........................................8
1.2.8 X124B - TS4 Exciter B: (BNC Socket, 75 Ohm) ...........................................9
1.2.9 X131A - TS1/2 IN Monitoring Exciter A: (BNC Socket) ................................9
1.2.10 X131B - TS1/2 IN Monitoring Exciter B: (BNC Socket) ................................9
1.2.11 X132A - TS3/4 IN Monitoring Exciter A: (BNC Socket) ................................9
1.2.12 X132B - TS3/4 IN Monitoring Exciter B: (BNC Socket) ..............................10
1.2.13 X141A - 1PPS Exciter A: (BNC Socket, 50 Ohm) ......................................10
1.2.14 X141B - 1PPS Exciter B: (BNC Socket, 50 Ohm) ......................................10
1.2.15 X142A - 1PPS Monitoring Exciter A: (BNC Socket, 50 Ohm) ....................10

Chapter 9 Annex
2099.9595.72 - 9.02 - E-1
1.2.16 X142B- 1PPS Monitoring Exciter B: (BNC Socket, 50 Ohm) .....................11
1.2.17 X143A - 10MHz REF.INPUT Exciter A: (BNC Socket, 50 Ohm) ................11
1.2.18 X143B - 10MHz REF.INPUT Exciter B: (BNC Socket, 50 Ohm) ................11
1.2.19 RF Transmitter Output: (EIA 1 5/8", Flange 50 Ohm) ................................11

Chapter 9 Annex
2099.9595.72 - 9.1 - E-1
1 Interface Description
1.1 Front-Panel Interfaces
1.1.1 Q1 - AC Supply Input / Protective Earth
1.1.2 X57 - Optional Connector Kit ZR800Z1
1.1.3 X33 - External Fan (Optional): (Wago Plug-In Terminal)
Signal name Direction Value range Contact Remark
PHASE L1 Input 400 V ±15% Q1.T1 Three-phase current input L1
PHASE L2 Input 400 V ±15% Q1.T2 Three-phase current input L2
PHASE L3 Input 400 V ±15% Q1.T3 Three-phase current input L1
NEUTRAL N Input 0 V Q1.N Neutral-conductor input N
PROTECTION
EARTH PE
Input 0 V X.PE PE terminal
PROTECTION
EARTH PE
Input 0 V PE pin PE station
Signal name Direction Value range Contact Remark
PHASE L1 Input 230 V X57.L1 Separate circuit
NEUTRAL N Input 0 V X57.N
PROTECTION
EARTH PE
Input 0 V X57.PE
Signal name Direction Value range Contact Remark
PHASE L1 Input 230 V X33.1 Line protection F8 [3A]
NEUTRAL N Input 0 V X33.2

Chapter 9 Annex
2099.9595.72 - 9.2 - E-1
External fan for dummy antenna (optional): (Wago plug-in terminal)
1.1.4 X33 - External Absorber Cooling (Optional): (Wago Plug-In
Terminal)
1.1.5 X41 - RF Loop: (Wago Plug-In Terminal)
PROTECTION
EARTH PE
Input 0 V X33.3
Signal name Direction Value range Contact Remark
PHASE L1 Input 230 V X33.4 Line protection F8 [3A]
NEUTRAL N Input 0 V X33.5
PROTECTION
EARTH PE
Input 0 V X33.6
Signal name Direction Value range Contact Remark
PHASE L1 Input 230 V X34.1 Line protection F8 [3A]
NEUTRAL N Input 0 V X34.2
PROTECTION
EARTH PE
Input 0 V X34.3
Signal name Direction Value range Contact Remark
MAIN TX LOOP Input -12 V ±2 V X41.1 -12 V floating
LOOP COM (+) Output +12 V ±2 V X41.2 +12 V floating
RESERVE TX
LOOP
Input -12 V ±2 V X41.3 -12 V floating
LOOP COM (+) Output +12 V ±2 V X41.4 +12 V floating
Signal name Direction Value range Contact Remark

Chapter 9 Annex
2099.9595.72 - 9.3 - E-1
1.1.6 X42 - Absorber Monitoring: (Wago Plug-In Terminal)
1.1.7 X43 - Absorber Monitoring: (Wago Plug-In Terminal)
1.1.8 X44 - Overcurrent Monitoring for External Fan: (Wago Plug-
In Terminal)
Signal name Direction Value range Contact Remark
FAULT SYSTEM
ABSORBER
Input TTL X42.1 Jumper to 0 V
REF RACK
SIGNALS
Output 0 V X42.2 Reference 0 V
FAULT RACK
ABSORBER
Input TTL X42.3 Jumper to 0 V
REF RACK
SIGNALS
Output 0 V X42.4 Reference 0 V
Signal name Direction Value range Contact Remark
FAULT
COOLING 2
Input TTL X43.1 Jumper to 0 V
REF RACK
COOLING
Input 0 V X43.2 Reference 0 V
FAULT
COOLING 1
Input TTL X43.3 Jumper to 0 V
REF RACK
SIGNALS
Input 0 V X43.4 Reference 0 V
WARNING
COOLING
Input TTL X43.5 Jumper to 0 V
REF RACK
SIGNALS
Input 0 V X43.6 Reference 0 V
Signal name Direction Value range Contact Remark
FAULT EXT:
COOLING
Input TTL X44.1 Jumper to 0 V
REF RACK
SIGNALS
Output 0 V X44.4 Reference 0 V

Chapter 9 Annex
2099.9595.72 - 9.4 - E-1
1.1.9 X100A - Ethernet A Remote (Standard): (8-Pin Socket)
1.1.10 X100B - Ethernet B Remote (Option N+1): (8-Pin Socket)
Signal name Direction Value range Contact Remark
TX+ Output Ethernet X100A.1 Transmitting line
TX- Output Ethernet X100A.2 Transmitting line
RX+ Input Ethernet X100A.3 Receiving line
Bidirect. 75 Ω termina-
tion
X100A.4
Bidirect. 75 Ω termina-
tion
X100A.5
RX- Input Ethernet X100A.6 Receiving line
Bidirect. 75 Ω termina-
tion
X100A.7
Bidirect. 75 Ω termina-
tion
X100A.8
Signal name Direction Value range Contact Remark
TX+ Output Ethernet X100B.1 Transmitting line
TX- Output Ethernet X100B.2 Transmitting line
RX+ Input Ethernet X100B.3 Receiving line
Bidirect. 75 Ω termina-
tion
X100B.4
Bidirect. 75 Ω termina-
tion
X100B.5
RX- Input Ethernet X100B.6 Receiving line
Bidirect. 75 Ω termina-
tion
X100B.7
Bidirect. 75 Ω termina-
tion
X100B.8

Chapter 9 Annex
2099.9595.72 - 9.5 - E-1
1.1.11 X232 RS232: (9-Pin D-Sub Socket)
1.1.12 X101A - CAN Bus Rack Bus A: (9-Pin D-Sub Socket)
1.1.13 X101B - CAN Bus Rack Bus B: (9-Pin D-Sub Socket)
Signal name Direction Value range Contact Remark
n.c. X232.1 Transmitting line
RS232_TX Output RS-232 X232.2 Transmitting line
RS232_RX Input RS-232 X232.3 Receiving line
n.c. X232.4
GND Bidirect. X232.5
n.c. X232.6
n.c. X232.7
n.c. X232.8
Signal name Direction Value range Contact Remark
12V_RED Bidirect. 12 V ±1 V X101A.1 Redundant 12 V supply
RC_A_CAN_L Bidirect. CAN-Level X101A.2 CAN bus signal
CAN_GND Bidirect. 0 V X101A.3 CAN GND
12V_RED Bidirect. 12 V ±1 V X101A.4 Redundant 12 V supply
CAN_SHLD Bidirect. GND X101A.5 Shield
GND Bidirect. GND X101A.6 GND
RC_A_CAN_H Bidirect. CAN+Level X101A.7 CAN bus signal
12V_ASI Bidirect. 12 V ±1.5 V X101A.8
CAN_V+ Bidirect. 12 V ±1 V X101A.9
Signal name Direction Value range Contact Remark
12V_RED Bidirect. 12 V ±1 V X101B.1 Redundant 12 V supply

Chapter 9 Annex
2099.9595.72 - 9.6 - E-1
1.1.14 X101C - CAN Bus Rack Bus C - Ext. Pump: (9-Pin D-Sub
Socket)
RC_A_CAN_L Bidirect. CAN-Level X101B.2 CAN bus signal
CAN_GND Bidirect. 0 V X101B.3 CAN GND
12V_RED Bidirect. 12 V ±1 V X101B.4 Redundant 12 V supply
CAN_SHLD Bidirect. GND X101B.5 Shield
GND Bidirect. GND X101B.6 GND
RC_A_CAN_H Bidirect. CAN+Level X101B.7 CAN bus signal
12V_ASI Bidirect. 12 V ±1.5 V X101B.8
CAN_V+ Bidirect. 12 V ±1 V X101B.9
Signal name Direction Value range Contact Remark
RS232_RxD0 Input RS232 X101C.1 Internal serial interface, rack
controller
C_CAN_L Bidirect. CAN-Level X101C.2 CAN bus signal
CAN_GND Bidirect. 0 V X101C.3 CAN GND
BOOT Input TTL X101C.4 Bootstrap mode key for rack
controller
CAN_SHLD Bidirect. GND X101C.5 Shield
GND Bidirect. GND X101C.6 GND
C_CAN_H Bidirect. CAN+Level X101C.7 CAN bus signal
RS232_TxD0 Output RS232 X101C.8 Internal serial interface, rack
controller
CAN_V+ Bidirect. 12 V ±1.5 V
Imax = 0.1 A
X101C.9 Supply of external bus driver
component from pump con-
trol
Signal name Direction Value range Contact Remark

Chapter 9 Annex
2099.9595.72 - 9.7 - E-1
1.1.15 X102A - ANTENNA 1: (N Socket, 50 Ohm)
1.1.16 X102B - ANTENNA 2: (N Socket, 50 Ohm)
1.2 Interfaces on Transmitter Top
1.2.1 X121A - TS1 Exciter A: (BNC Socket, 75 Ohm)
1.2.2 X121B - TS1 Exciter B: (BNC Socket, 75 Ohm)
Signal name Direction Value range Contact Remark
ANTENNA 1 Input X102A.1 Only for DTV TX level
depending on application
GND Bidirect. 0 V X102A.2
Signal name Direction Value range Contact Remark
ANTENNA 2 Input X102B.1 Only for DTV TX level
depending on application
GND Bidirect. 0 V X102B.2
Signal name Direction Value range Contact Remark
TS1 Input ASI/SMPTE310M X121A.1 TS1 Exciter A
GND Bidirect. X121A.2 GND/shield
Signal name Direction Value range Contact Remark
TS1 Input ASI/SMPTE310M X121B.1 TS1 Exciter B
GND Bidirect. X121B.2 GND/shield

Chapter 9 Annex
2099.9595.72 - 9.8 - E-1
1.2.3 X122A - TS2 Exciter A: (BNC Socket, 75 Ohm)
1.2.4 X122B - TS2 Exciter B: (BNC Socket, 75 Ohm)
1.2.5 X123A - TS3 Exciter A: (BNC Socket, 75 Ohm)
1.2.6 X123B - TS3 Exciter B: (BNC Socket, 75 Ohm)
1.2.7 X124A - TS4 Exciter A: (BNC Socket, 75 Ohm)
Signal name Direction Value range Contact Remark
TS2 Input ASI/SMPTE310M X122A.1 TS2 Exciter A
GND Bidirect. X122A.2 GND/shield
Signal name Direction Value range Contact Remark
TS2 Input ASI/SMPTE310M X122B.1 TS2 Exciter B
GND Bidirect. X122B.2 GND/shield
Signal name Direction Value range Contact Remark
TS3 Input ASI/SMPTE310M X123A.1 TS3 Exciter A
GND Bidirect. X123A.2 GND/shield
Signal name Direction Value range Contact Remark
TS3 Input ASI/SMPTE310M X123B.1 TS3 Exciter B
GND Bidirect. X123B.2 GND/shield
Signal name Direction Value range Contact Remark
TS4 Input ASI/SMPTE310M X124A.1 TS4 Exciter A

Chapter 9 Annex
2099.9595.72 - 9.9 - E-1
1.2.8 X124B - TS4 Exciter B: (BNC Socket, 75 Ohm)
1.2.9 X131A - TS1/2 IN Monitoring Exciter A: (BNC Socket)
1.2.10 X131B - TS1/2 IN Monitoring Exciter B: (BNC Socket)
1.2.11 X132A - TS3/4 IN Monitoring Exciter A: (BNC Socket)
GND Bidirect. X124A.2 GND/shield
Signal name Direction Value range Contact Remark
TS4 Input ASI/SMPTE310M X124B.1 TS4 Exciter B
GND Bidirect. X124B.2 GND/shield
Signal
name Direction Value range Contact Remark
TS1/2 IN
Monitoring
Output ASI/SMPTE310M X131A.1 TS1/2 Monitoring Exciter A
GND Bidirect. X131A.2 GND/shield
Signal
name Direction Value range Contact Remark
TS1/2 IN
Monitoring
Output ASI/SMPTE310M X131B.1 TS1/2 Monitoring Exciter B
GND Bidirect. X131B.2 GND/shield
Signal
name Direction Value range Contact Remark
TS3/4 IN
Monitoring
Output ASI/SMPTE310M X132A.1 TS3/4 Monitoring Exciter A
Signal name Direction Value range Contact Remark

Chapter 9 Annex
2099.9595.72 - 9.10 - E-1
1.2.12 X132B - TS3/4 IN Monitoring Exciter B: (BNC Socket)
1.2.13 X141A - 1PPS Exciter A: (BNC Socket, 50 Ohm)
1.2.14 X141B - 1PPS Exciter B: (BNC Socket, 50 Ohm)
1.2.15 X142A - 1PPS Monitoring Exciter A: (BNC Socket, 50 Ohm)
GND Bidirect. X132A.2 GND/shield
Signal
name Direction Value range Contact Remark
TS3/4 IN
Monitoring
Output ASI/SMPTE310M X132B.1 TS3/4 Monitoring Exciter B
GND Bidirect. X132B.2 GND/shield
Signal name Direction Value range Contact Remark
1PPS_EXTERN Input TTL level
(pos.edge)
X141A.1 Seconds pulse from exter-
nal GPS receiver, exciter A
GND Bidirect. X141A.2 GND/shield
Signal name Direction Value range Contact Remark
1PPS_EXTERN Input TTL level
(pos.edge)
X141B.1 Seconds pulse from exter-
nal GPS receiver, exciter B
GND Bidirect. X141B.2 GND/shield
Signal name Direction Value range Contact Remark
1PPS Monitor-
ing
Input TTL level
(pos.edge)
X142A.1 Monitor output of internally
used 1PPS (exciter A)
Signal
name Direction Value range Contact Remark

Chapter 9 Annex
2099.9595.72 - 9.11 - E-1
1.2.16 X142B- 1PPS Monitoring Exciter B: (BNC Socket, 50 Ohm)
1.2.17 X143A - 10MHz REF.INPUT Exciter A: (BNC Socket, 50 Ohm)
1.2.18 X143B - 10MHz REF.INPUT Exciter B: (BNC Socket, 50 Ohm)
1.2.19 RF Transmitter Output: (EIA 1 5/8", Flange 50 Ohm)
GND Bidirect. X142A.2 GND/shield
Signal name Direction Value range Contact Remark
1PPS Monitor-
ing
Input TTL level
(pos.edge)
X142B.1 Monitor output of internally
used 1PPS (exciter B)
GND Bidirect. X142B.2 GND/shield
Signal name Direction Value range Contact Remark
10 MHz REF
INPUT
Input -5.0 dB to 20 dBm
or TTL
X143A.1 10 MHz reference for
exciter A
GND Bidirect. X142A.2 GND/shield
Signal name Direction Value range Contact Remark
10 MHz REF
INPUT
Input -5.0 dB to 20 dBm
or TTL
X143B.1 10 MHz reference for
exciter B
GND Bidirect. X142B.2 GND/shield
Signal name Direction Value range Contact Remark
RF transmitter
output
Output PmaxAVG = 1950 W RF RF transmitter output
GND Bidirect. RF GND/shield
Signal name Direction Value range Contact Remark

Broadcasting Division
2098.1190.72 - 9.B - E-1
Drawings and Diagrams
TRANSMITTER
Printed in Germany

Broadcasting Division
2098.1190.72 - 9.C - E-1
Spare Parts Lists
TRANSMITTER