Rohde and Schwarz NV830X UHF 1.8kW maximum Digital TV transmitter User Manual 32 SLX8000 12 12 07 01 00
Rohde & Schwarz Inc UHF 1.8kW maximum Digital TV transmitter 32 SLX8000 12 12 07 01 00
Contents
- 1. User Manual Part 1
- 2. User Manual Part 2
- 3. User Manual Part 3
User Manual Part 3
Broadcasting Division CHAPTER 6 MAINTENANCE Printed in Germany 2095.7346.32 - 6.0 - E-1 Chapter 6 Maintenance CONTENTS 1 Maintenance Intervals ..................................................................... 1 1.1 Maintenance of Subcontractor Products .....................................................1 2 Maintenance Tasks .......................................................................... 2 2.1 Replacing BIOS Battery in R&S NetCCU800 ................................................2 2.2 Replacing Fans on SX800 Exciter .................................................................2 2.3 Software Update .............................................................................................2 2098.1190.72 - 6.01 - E-3 Chapter 6 2098.1190.72 - 6.02 - Maintenance E-3 Chapter 6 Maintenance Maintenance Intervals The following maintenance work must be performed at regular intervals: 1.1 Maintenance interval Task Procedure described in: 2x per year Check the operating values (e.g. output power, control values, etc) 1x per year Check and, if necessary, change the backup battery of the transmitter control unit (R&S NetCCU800) Chapter "Maintenance" in the R&S NetCCU800 manual After 5 years and then 1x per year Check whether the two rack fans make noises when in operation; replace them if necessary Chapter "Service“ in this manual After 5 years and then 1x per year Check whether the fans make noises when in operation; replace them if necessary Chapter "Maintenance" in the exciter manual Maintenance of Subcontractor Products Subcontractor products such as external air filters must be maintained in accordance with the maintenance instructions from the respective manufacturer and for the respective product. 2098.1190.72 - 6.1 - E-3 Chapter 6 Maintenance Maintenance Tasks 2.1 Replacing BIOS Battery in R&S NetCCU800 Note The chapter "Maintenance" in the R&S NetCCU800 manual describes how to replace the BIOS battery. 2.2 Replacing Fans on SX800 Exciter Note The chapter "Maintenance" in the exciter manual describes how to replace the fans. 2.3 Software Update You can use the R&S NetCCU800 to install software updates for the R&S NetCCU800 itself as well as for all exciters connected to the R&S NetCCU800. The update data is first transferred to the R&S NetCCU800. The update for the connected exciters is then performed in a second step. The software update is only possible if the R&S NetCCU800 is remotely connected to a network client on which the new software and the program for performing the update are installed. You perform a software update for the NSU/NCU in the same way. It is also possible to update exciters via the NCU/NSU Update menu. Note The update program was developed for performing updates of various Rohde&Schwarz software solutions. For this reason, some functions of the program which are not relevant to updating software via the R&S NetCCU800 are omitted in the description below. The procedure for performing a software update is as follows. 1. Log on as Maintenance in the menu operation. 2. Call up NetCCU > NetCCU Setup > SW Maintenance. 3. Set the R&S NetCCU800 to Update mode using the Start function under SW Update Operation. 2098.1190.72 - 6.2 - E-3 Chapter 6 Maintenance 4. Start the installation software on the client computer. The start window of the R&S Software Distributor opens. 5. Confirm the default setting Remote Installation by clicking on Next. The software updates that can be installed will be displayed. You can obtain additional information about the update you select by highlighting it with the cursor and then clicking Info. 2098.1190.72 - 6.3 - E-3 Chapter 6 Maintenance 6. Select the required updates and confirm installation of the updates by clicking Next. All instruments found in the network are displayed under the device name that you assigned in the Maintenance menu window. 7. Select the instrument and start the update by clicking Install. After the update has been completed, a corresponding message will appear in the field at the bottom left of the window. The R&S NetCCU800 is rebooted automatically. If connected transmitter components cannot be found because the R&S NetCCU800 was not in Update mode, the message "No R&S Device found" is displayed at the bottom left of the window. You have the following option: 1. On the R&S NetCCU800, open the menu NetCCU > NetCCU Setup > SW Maintenance and start the Update mode using the Start function under SW Update Operation. 2098.1190.72 - 6.4 - E-3 Chapter 6 Maintenance 2. Click Rescan in the R&S Software Distributor window. The special components are displayed and you can perform the update in the way described above. Note None of the remaining functions in the R&S Software Distribution window are relevant for updates via the R&S NetCCU800; settings that can be accessed using these functions must not be changed. Performing software updates for exciters When the update procedure described above is performed, the software updates for the exciter(s) are also transferred to the R&S NetCCU800. The update for the exciter(s) is started directly via the R&S NetCCU800. 1. Set the R&S NetCCU800 to the Update mode in the way described above. 2. Start the installation software. 3. Select the software package for the exciter. 4. Search for instruments in the network and select the exciter for which you want to perform a software update. 5. Install the update. After the update procedure has been completed, the respective exciter is rebooted automatically. 2098.1190.72 - 6.5 - E-3 Chapter 6 2098.1190.72 - 6.6 - Maintenance E-3 Broadcasting Division CHAPTER 7 TROUBLESHOOTING Printed in Germany 2095.7346.32 - 7.0 - E-1 Chapter 7 Troubleshooting CONTENTS 1 Information ....................................................................................... 1 2098.1190.72 - 7.01 - E-1 Chapter 7 Troubleshooting Information Troubleshooting information will be provided at a later date. 2098.1190.72 - 7.1 - E-1 Broadcasting Division CHAPTER 8 SERVICE Printed in Germany 2095.7346.32 - 8.0 - E-1 Chapter 8 Service CONTENTS 1 Necessary Tools and Test Equipment ........................................... 1 2 Overview ........................................................................................... 2 3 Preparations ..................................................................................... 3 3.1 Safety ...............................................................................................................3 3.2 Rack Cabling ...................................................................................................3 3.3 Removing Front Panel/Rear Panel ................................................................4 4 Power Distribution ........................................................................... 5 4.1 Replacing Main Switch ...................................................................................5 4.1.1 Removing Main Switch .................................................................................5 4.1.2 Installing Main Switch ...................................................................................6 4.2 Replacing Motor Protection Switches ..........................................................7 4.2.1 Removing Motor Protection Switch ..............................................................7 4.2.2 Installing Motor Protection Switch ................................................................9 4.3 Replacing Power Distribution Board ..........................................................10 4.3.1 Removing Power Distribution Board ..........................................................10 4.3.2 Installing Power Distribution Board ............................................................11 4.4 Replacing Automatic Line Fuses ................................................................12 4.4.1 Removing Automatic Line Fuse .................................................................12 4.4.2 Installing Automatic Line Fuse ...................................................................13 4.5 Replacing Auxiliary Power Supply Unit .....................................................13 4.5.1 Removing Auxiliary Power Supply Unit ......................................................13 4.5.2 Installing the Auxiliary Power Supply Unit ..................................................14 5 Transmitter Control Unit ............................................................... 15 5.1 Replacing R&S NetCCU800 .........................................................................15 5.1.1 Removing R&S NetCCU800 ......................................................................15 5.1.2 Preparing R&S NetCCU800 for Installation ................................................16 5.1.3 Installing R&S NetCCU800 ........................................................................17 5.2 Replacing Rack Controller ...........................................................................17 5.2.1 Removing Rack Controller .........................................................................17 5.2.2 Installing Rack Controller ...........................................................................18 2098.0188.72 - 8.01 - E-1 Chapter 8 Service 6 Exciter Components ...................................................................... 19 6.1 Replacing Exciter .........................................................................................19 6.1.1 Removing Exciter .......................................................................................19 6.1.2 Configuring Exciter .....................................................................................20 6.1.3 Installing Exciter .........................................................................................21 6.2 Replacing Exciter Switch .............................................................................21 6.2.1 Removing Exciter Switch ............................................................................21 6.2.2 Installing Exciter Switch ..............................................................................22 7 Output Stage Components ........................................................... 23 7.1 Replacing Amplifiers ....................................................................................23 7.1.1 Removing Amplifier ....................................................................................23 7.1.2 Installing Amplifier ......................................................................................24 7.2 Replacing Absorber .....................................................................................24 7.2.1 Removing Absorber ....................................................................................24 7.2.2 Installing Absorber ......................................................................................25 8 Harmonics Filter ............................................................................ 26 8.1 Replacing Harmonics Filter .........................................................................26 8.1.1 Removing Harmonics Filter ........................................................................26 8.1.2 Installing Harmonics Filter ..........................................................................27 9 Cooling System .............................................................................. 28 9.1 Replacing Fans .............................................................................................28 9.1.1 Removing Fan ............................................................................................28 9.1.2 Installing Fan ..............................................................................................30 9.2 Replacing Starting Capacitors ....................................................................30 9.2.1 Removing Starting Capacitor .....................................................................30 9.2.2 Installing Starting Capacitor .......................................................................31 9.3 Replacing Differential Pressure Gages ......................................................31 9.3.1 Removing Differential Pressure Gage ........................................................32 9.3.2 Installing Differential Pressure Gage ..........................................................32 9.4 Replacing Temperature Sensors ................................................................33 9.4.1 Removing Temperature Sensor .................................................................33 9.4.2 Installing Temperature Sensor ...................................................................34 2098.0188.72 - 8.02 - E-1 Chapter 8 Service Necessary Tools and Test Equipment The specified tools and test equipment include only those items needed for removing system components and carrying out simple checks on them. Depending on the service work to be performed, you will require the following tools: Screwdriver No. 0 Screwdriver No. 1 Screwdriver No. 2 Phillips screwdriver No. 0 Phillips screwdriver No. 1 Phillips screwdriver No. 2 Torx screwdriver No. 8 Torx screwdriver No. 9 Torx screwdriver No. 20 Hexagonal socket No. 3 Hexagonal socket No. 6 Open-end wrench No. 7 Open-end wrench No. 8 Open-end wrench No. 13 Multimeter 2098.0188.72 - 8.1 - E-1 Chapter 8 Service Overview You can remove and exchange the following units and transmitter components if errors occur: Power distribution – Main switch – Motor protection switches – Automatic line fuses – Power distribution board – Auxiliary power supply Transmitter control unit – R&S NetCCU800 – Rack controller Exciter components – Exciter – Exciter switch (for exciter standby) Output stage components – Amplifiers – Absorber Harmonics filter Cooling system – Fans – Starting capacitors – Differential pressure gages – Temperature sensors 2098.0188.72 - 8.2 - E-1 Chapter 8 Preparations 3.1 Safety Service WARNING! All service work should only be carried out by qualified personnel and only on components that have been disconnected from the power supply. Heavy components such as amplifiers must always be exchanged using a team of two people. Note Full information on the subject of safety can be found in the section "Safety". 3.2 Rack Cabling The standard components of the transmitter are fully cabled together on delivery. You need to reconnect the separate replacement instruments during service work. Each cable has a yellow collar at each end, inscribed with the cable number (W...) and the intended purpose (module number A..., connector number X...). This makes it easier to connect the cable concerned to the intended slot or connection point, since the modules are provided with an engraved or self-adhesive circuit diagram. For easy connection of replacement instruments or devices proceed as follows: 1. Find the plug (connector) number from the yellow collar on the cable. 2. Find the same number on the instrument you wish to connect (by looking for the female connector or circuit diagram). 3. Insert the plug connector into the corresponding female connector. 2098.0188.72 - 8.3 - E-1 Chapter 8 3.3 Service Removing Front Panel/Rear Panel To remove the front panel/rear panel proceed as follows: Using a Torx screwdriver No. 20, remove the front or rear panel. Fig. 1 Ground terminal of a front panel/rear panel 2098.0188.72 - 8.4 - E-1 Chapter 8 Service Power Distribution You can replace the following power distribution components: Main switch (power supply terminal) Motor protection switch Automatic line fuse Power distribution board Auxiliary power supply 4.1 Replacing Main Switch WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. 4.1.1 Removing Main Switch To remove the main switch proceed as follows: 1. Using a Torx screwdriver No. 20, remove the front panel of the power distribution. 2. Unscrew the rotary knob and the main switch cover. Fig. 2 Unscrewing the rotary knob and cover 3. Undo the screws on the switch housing (Phillips screwdriver No. 1) and remove the connected cables. 2098.0188.72 - 8.5 - E-1 Chapter 8 Service 4. Undo the screws on the terminal rack on the left of the main switch and slide the terminal rack to the left. 5. Pull forward the black stop lever on the underside of the main switch. 6. Carefully take out the main switch. Fig. 3 Taking out the main switch 4.1.2 Installing Main Switch 1. Replace the main switch by proceeding in the reverse order. 2. Insert the cables into the corresponding openings and fasten them with screws. Note Notice how the cables are labeled and make sure they are in the right sequence, since two of the three phase cables are the same color (black). 3. Measure the rotary field with the aid of a rotary field meter. If the rotary field is correct, continue with the next step; if it is wrong, swap two wires from the cable and measure the rotary field again. 4. Screw the main switch cover and the rotary knob back on. Note 2098.0188.72 When working on the transmitter rack the main switch can be locked in the "OFF" position (see next figure). - 8.6 - E-1 Chapter 8 Service Fig. 4 Main switch locked 4.2 Replacing Motor Protection Switches WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. 4.2.1 Removing Motor Protection Switch To remove the motor protection switch proceed as follows: 1. Using a Torx screwdriver No. 20, remove the front panel of the power distribution. 2. Pull the blue-green shorting plug forward. If necessary you may use a screwdriver (No. 0) suited to the relatively high amounts of force that are needed. 2098.0188.72 - 8.7 - E-1 Chapter 8 Service 3. Press the motor protection switch sharply downward and pull it forward by the bottom edge. Because there is a spring clip behind the upper edge, you can only release the switch downward. 1) Spring clip 4. Use a screwdriver to open the cable clamps and pull out the connected cable (see figure). 2098.0188.72 - 8.8 - E-1 Chapter 8 Service Fig. 5 Opening the cable clamp on the motor protection switch 4.2.2 Installing Motor Protection Switch Replace the motor protection switch by proceeding in the reverse order. Note When replacing, feed the shorting plug right in and push the switch into place with some force. Fig. 6 Installing the motor protection switch 2098.0188.72 - 8.9 - E-1 Chapter 8 Service 1) Room for the shorting plug pins 4.3 Replacing Power Distribution Board WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. 4.3.1 Removing Power Distribution Board To remove the power distribution board proceed as follows: 1. Using a Torx screwdriver No. 20, remove the front panel of the power distribution. 2. Remove all plugs before removing the power distribution board. 3. Unscrew the SUB-D connector on the right of the longitudinal edge (two screws). 4. Use a Phillips screwdriver No. 1 to undo eight screws on the automatic line fuses. Fig. 7 Removing the power distribution board 1) Screws on the automatic line fuses 2) Screws on the SUB-D connector 5. Using a Torx screwdriver No. 8 remove seven fixing screws from the power distribution board. 2098.0188.72 - 8.10 - E-1 Chapter 8 Service Fig. 8 Removing the power distribution board 1) Fixing screws on the power distribution board 6. To take out the PCB, first slide it downward. 4.3.2 Installing Power Distribution Board Replace the power distribution board by proceeding in the reverse order. Note When replacing the power distribution board, make sure that it feeds into the right slots. Fig. 9 Installing the power distribution board 1) Wrong 2) Right 3) Pressing with a screwdriver visibly opens the right chamber 2098.0188.72 - 8.11 - E-1 Chapter 8 4.4 Service Replacing Automatic Line Fuses WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. 4.4.1 Removing Automatic Line Fuse Note Before removing an automatic line fuse, the power distribution board must be removed (see "Removing the Power Distribution Board"). To remove the automatic line fuse proceed as follows: 1. Remove the power distribution board. 2. From above, grip the back of the automatic line fuse you wish to remove and undo the white plastic springs. 3. Remove the automatic line fuse. 2098.0188.72 - 8.12 - E-1 Chapter 8 Service Fig. 10 Automatic line fuse 1) Upper plastic spring 2) Lower plastic spring 4.4.2 Installing Automatic Line Fuse Replace the automatic line fuse by proceeding in the reverse order. Note Before putting it back into operation, make sure that all terminals are correctly connected. 4.5 Replacing Auxiliary Power Supply Unit WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. 4.5.1 Removing Auxiliary Power Supply Unit To remove the auxiliary power supply proceed as follows: 1. Using a Torx screwdriver No. 20, remove the front panel of the power distribution. 2. Undo the auxiliary power supply cables (X35, X45) from the power distribution board. Trace the two cables and if necessary cut off the cable ties. 3. Undo two Torx screws on the front of the power supply unit. 4. Remove the power supply unit. 2098.0188.72 - 8.13 - E-1 Chapter 8 Service Fig. 11 Removing the power supply unit 4.5.2 Installing the Auxiliary Power Supply Unit Replace the power supply unit by proceeding in the reverse order. 2098.0188.72 - 8.14 - E-1 Chapter 8 Service Transmitter Control Unit You can replace the following transmitter control unit components: R&S NetCCU800 Rack controller 5.1 Replacing R&S NetCCU800 WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. 5.1.1 Removing R&S NetCCU800 Note Removing the R&S NetCCU800 does not affect transmitter operation. 1. Switch off automatic line fuse F1. 2. Undo the two captive screws (Torx screwdriver No. 20) at the front brackets of the R&S NetCCU800 and exciter (the screws are next to the handles). 3. Grip the handles and slowly pull the rackmount out of the rack as far as it will go (the guide rails engage and are locked in place). 4. Disconnect the power cable from the rear panel of the R&S NetCCU800. 5. Disconnect all cables from the rear panel of the R&S NetCCU800. 2098.0188.72 - 8.15 - E-1 Chapter 8 Service Fig. 12 Removing R&S NetCCU800 from transmitter rack 1) 2) 3) 4) 5) Captive screws at front panel of installed units (here: exciter and R&S NetCCU800) Screws securing R&S NetCCU800 to rackmount Guide rails Support bracket for R&S NetCCU800 Safety lever for releasing guide rail catch 6. Undo the two fastening screws (Torx screwdriver No. 9) from the rackmount on both sides of the R&S NetCCU800. Note Removal should be performed by two persons. When pulled out by the handles, the R&S NetCCU800 must be supported from below as soon as the support brackets no longer support it. 7. Pull the R&S NetCCU800 out of the rackmount. 5.1.2 Preparing R&S NetCCU800 for Installation The replacement R&S NetCCU800 is delivered as a desktop unit and must be prepared for installation as follows. Remove the protective rubber caps on the rear feet of the instrument. The replacement unit is as a rule preconfigured with the default configuration. So that the new R&S NetCCU800 does not adversely affect the operation of the transmitter when it is put into operation in the transmitter rack, it must first be configured specifically for the transmitter. 2098.0188.72 - 8.16 - E-1 Chapter 8 Service Put the R&S NetCCU800 into local mode and configure the unit specifically for the transmitter concerned, as described in the chapter "Commissioning". 5.1.3 Installing R&S NetCCU800 To install the unit in the transmitter, reverse the procedure used to remove it. 1. Slide the R&S NetCCU800 horizontally into the rackmount on the lowest support brackets until the screw holes in the plug-in housing and on the side panels of the R&S NetCCU800 line up. 2. Fasten the R&S NetCCU800 with two screws on each side. 3. Connect the cables to the R&S NetCCU800 according to the labeling (see yellow cable collars). 4. Undo the latch on the guide rails. Push down the safety lever on the right while simultaneously pushing up the safety lever on the left and slide the rackmount into the rack. 5. Retighten the two captive screws on the front panel of the R&S NetCCU800 and exciter. 6. Switch the automatic line fuse F1 on again. 5.2 Replacing Rack Controller WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. 5.2.1 Removing Rack Controller Note The rack controller is underneath the R&S NetCCU800. 1. Remove the cover by undoing the two screws (Torx screwdriver No. 20). Fig. 13 Removal of rack controller from transmitter rack: removing cover 2098.0188.72 - 8.17 - E-1 Chapter 8 Service 2. Turn the two screws (Torx screwdriver No. 20) on the sides alternately by a few turns. This pushes the rack controller out of the rack and prevents it from tilting. Fig. 14 Removal of rack controller from transmitter rack: undoing fastening screws 3. Remove the rack controller from the rack. Fig. 15 Removal of rack controller from transmitter rack: removing rack controller 5.2.2 Installing Rack Controller To install the rack controller in the transmitter, reverse the procedure used to remove it. 2098.0188.72 - 8.18 - E-1 Chapter 8 Service Exciter Components You can replace the following exciter components: Exciter Exciter Switch 6.1 Replacing Exciter WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. 6.1.1 Removing Exciter 1. Switch off automatic line fuse F2 (exciter A) or F3 (exciter B). 2. Undo the two captive screws (Torx screwdriver No. 20) from the R&S NetCCU800 and exciter on the front brackets (next to the handles). 3. Using the handles, slowly pull out the rackmount from the rack as far as it will go (the guide rails will engage and lock in place). 4. Disconnect all cables from the rear panel of the exciter. 2098.0188.72 - 8.19 - E-1 Chapter 8 Service Fig. 16 Removing the exciter from the transmitter rack 1) 2) 3) 4) Captive screws at front panel of installed units (here: exciter and R&S NetCCU800) Screw-connections of the exciter on the rackmount Guide rails Safety lever for unlocking guide rail latch 5. On both sides of the exciter undo the two fixing screws (Torx screwdriver No. 9) from the rackmount. 6. Pull the exciter from the rackmount. 6.1.2 Configuring Exciter Before installing the replacement unit and restarting the transmitter, you should check whether the correct transmitter operating mode is set on the exciter. Proceed as follows: 1. Connect the exciter via the front-panel Ethernet port to a PC and put the unit into local mode. Note For more information on operating the separate unit, please refer to the Appendix to the exciter manual, section "Remote Operation of the Exciter". 2. Start the web browser GUI and log in with "Configuration" rights. 3. Call the Exciter *** > Setup > Tx Setup menu, go to Tx Mode and set the transmitter operating mode to "Med./High Power with NetCCU". 4. Call the Exciter *** > Setup > Exciter Setup > Common menu and under Digital Standard set the appropriate digital TV standard to which the R&S NetCCU800 is already configured. 2098.0188.72 - 8.20 - E-1 Chapter 8 Note 6.1.3 Service All the other exciter settings can be checked after installation in the transmitter and if necessary adjusted via the R&S NetCCU800. Installing Exciter To install the unit in the transmitter, reverse the procedure used to remove it. 1. Slide the exciter into the cabinet horizontally on the support brackets until the screw holes on the cabinet and on the side panels of the exciter match. 2. Fasten the exciter with two screws on each side. 3. Connect the cables to the exciter according to the labeling (see yellow cable collars). 4. Undo the latch on the guide rails. Push down the safety lever on the right while simultaneously pushing up the safety lever on the left and slide the rackmount into the rack. 5. Retighten the two captive screws on the front panel of the R&S NetCCU800 and exciter. 6. Switch the automatic line fuse F2 (exciter A) or F3 (exciter B) on again. 6.2 Replacing Exciter Switch WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. 6.2.1 Removing Exciter Switch In transmitters with the exciter standby option (2 exciters), the exciter switch is located behind the two exciters. Note To allow the exciter switch to be removed easily, you first need to remove the R&S NetCCU and exciter from the rack. 1. Undo the two captive screws at the front brackets of the R&S NetCCU800 and exciter (next to the handles). 2. Grip the handles and slowly pull the rackmount out of the rack as far as it will go (the guide rails engage and are locked in place). 3. Disconnect the power cable from the side of the exciter switch. 2098.0188.72 - 8.21 - E-1 Chapter 8 Service Fig. 17 Removing exciter switch from transmitter rack 4. Disconnect all cables from the rear of the exciter switch. 5. Undo the fastening screws on the exciter switch. 6. Pull the exciter switch from the transmitter rack. 6.2.2 Installing Exciter Switch To install the unit in the transmitter, reverse the procedure used to remove it. 1. Connect the cables to the exciter switch according to the labeling (see yellow cable collars). 2. Undo the latch on the guide rails. Simultaneously press the safety lever on the right side down and on the left side up, and slide the rackmount into the rack. 3. Retighten the captive screws on the front panel of the R&S NetCCU800 and exciter. 2098.0188.72 - 8.22 - E-1 Chapter 8 Service Output Stage Components You can replace the following output stage components: Amplifier Absorber Note Because of the extremely small probability of failure, replacement of the splitter-combiner unit will not be described. 7.1 Replacing Amplifiers When replacing an amplifier from the Rohde & Schwarz transmitters, you do not have to remove any of the lines since the connections on the rear panel of the device are connected to the rack using automatic connectors. 7.1.1 Removing Amplifier ATTENTION! Prior to being removed, the amplifier must be switched free of all voltages in order to prevent any possible damage to the device due to contact consumption. 1. Switch off the amplifier via the AC distributor in the transmitter rack (turn the the appropriate protective switch to the "OFF" position). Note The other devices in the transmitter rack can remain connected. A transmitter with multiple amplifiers can remain in operation with reduced power during the exchange of the amplifier. 2. Undo the four captive screws (Torx screwdriver No. 20) on each side of the front panel. 2098.0188.72 - 8.23 - E-1 Chapter 8 Service CAUTION! Risk of burns on the heat sink. Let the amplifier cool down for about five minutes with the transmitter cooling switched on before you remove it from the transmitter rack. CAUTION! When you pull it out of the transmitter rack, do not allow the amplifier to fall. Support it from below. The amplifier weighs about 28 kg so we suggest that you use two people to handle it. 3. Slowly pull the amplifier from the rack using the handles. The automatic connectors should release on the rear panel of the device. ATTENTION! To avoid damaging the connectors, do not place the amplifier on its back. 4. Put the amplifier down with the bottom of the instrument facing downward. 5. If the transmitter is to remain in operation with the remaining amplifiers, close the left and right vents at the vacant amplifier slot. 7.1.2 Installing Amplifier To install the unit in the transmitter, reverse the procedure used to remove it. 7.2 Replacing Absorber WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. 7.2.1 Removing Absorber To remove the absorber proceed as follows: 2098.0188.72 - 8.24 - E-1 Chapter 8 Service 1. Using a Torx screwdriver No. 20, remove the rear panel of the rack. 2. Disconnect the RF connecting cables W1, W2 and W3 to the splitter-combiner unit. 3. Using a Torx screwdriver No. 20 remove all six fixing screws. 4. Pull the absorber unit from the rackmount air outlet duct. Fig. 18 Removing the absorber 7.2.2 Installing Absorber To install the unit in the transmitter, reverse the procedure used to remove it. 2098.0188.72 - 8.25 - E-1 Chapter 8 Service Harmonics Filter In this transmitter family the harmonics filter is built into the RF line. 8.1 Replacing Harmonics Filter WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. Note The harmonics filter is lacquered in order to reduce the surface temperature, but high temperatures are nevertheless to be expected. 8.1.1 Removing Harmonics Filter Note The harmonics filter is connected to the RF chain by means of two rigid line brackets. So that the inner line of the lower rigid line (into the bandpass) stays fixed in place, the tensioning clamp of the lower rigid line bracket should be opened first. To remove the harmonics filter proceed as follows: 1. Open the tensioning clamp of the lower rigid line bracket on the rigid connection of the combiner. 2. Open the tensioning clamp of the upper rigid line bracket using an open-end wrench No. 7 or a Phillips screwdriver No. 2. 3. Pull the harmonics filter of the combiner rigid line down and to the right. 4. Pull the harmonics filter downward from the upper rigid line bracket. 2098.0188.72 - 8.26 - E-1 Chapter 8 Service Fig. 19 Removing the harmonics filter 8.1.2 Installing Harmonics Filter The replacement harmonics filter has no rigid line brackets. Remove the rigid line bracket from the old harmonics filter, attach the bracket to the new harmonics filter (top) and screw it firmly in place. To install the unit in the transmitter, reverse the procedure used to remove it. 2098.0188.72 - 8.27 - E-1 Chapter 8 Service Cooling System You can replace the following cooling system components: Fan Starting capacitor Differential pressure gage Temperature sensors 9.1 Replacing Fans WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. The transmitter rack contains two fans as standard; one of these can be reached only from the front and the other only from the back. However the removal sequence is the same in both cases. 9.1.1 Removing Fan Note Prior to removal make sure which of the two fans needs to be replaced. 1. Using a Torx screwdriver No. 20, remove the front panel of the power distribution to replace the front fan, or the rear panel of the transmitter to replace the rear fan. 2. Switch off automatic line fuse F6 (rear fan) or F7 (front fan). Note Wait two minutes before starting to remove the fan (to allow for the fan overrun time). 3. Undo the four screws on the fan housing and remove the cover. 2098.0188.72 - 8.28 - E-1 Chapter 8 Service Fig. 20 Undoing the screws from the fan housing 4. On the upper side of the fan housing is a retaining device that must be unscrewed using a Torx screwdriver No. 20. Fig. 21 Unscrewing the retaining device 5. Pull the power cable out of the connector and take away the air tube. 2098.0188.72 - 8.29 - E-1 Chapter 8 Service 6. Slide the fan slightly to the side, then pull it toward yourself and out of the fan housing. The fan is easy to remove due to the guide rails Fig. 22 Removing a fan 9.1.2 Installing Fan To install the unit in the transmitter, reverse the procedure used to remove it. 9.2 Replacing Starting Capacitors WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. 9.2.1 Removing Starting Capacitor Note Prior to removal make sure which of the two starting capacitors needs to be replaced. 2098.0188.72 - 8.30 - E-1 Chapter 8 Service 1. Using a Torx screwdriver No. 20, remove the front panel of the power distribution to replace the front starting capacitor, or the rear panel of the transmitter to replace the rear starting capacitor. 2. Switch off automatic line fuse F6 (fan 1, rear starting capacitor) or F7 (fan 2, front starting capacitor). 3. Remove the fan connector. 4. Undo the nut (M8, wrench width 13 mm) on the face plate of the capacitor. 5. Cut off the cable ties to free the cable. Fig. 23 Removing the starting capacitor 1) 2) 3) 4) 9.2.2 Connector (and socket) Cable ties Lock washer Nut (M8) Installing Starting Capacitor To install the unit in the transmitter, reverse the procedure used to remove it. Note The lock washer and M8 nut must be fastened together again. 9.3 Replacing Differential Pressure Gages WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. 2098.0188.72 - 8.31 - E-1 Chapter 8 Service 9.3.1 Removing Differential Pressure Gage Note Prior to removal make sure which of the two differential pressure gages needs to be replaced. 1. Using a Torx screwdriver No. 20, remove the rear panel of the rack. 2. Remove the air connector (plastic tube). 3. Disconnect the associated cable from the connector on X45 of the power distribution board. (Pins 1 and 2 for differential pressure gage 1, or pins 3 and 4 for differential pressure gage 2.) 4. Cut off the cable ties to free the cable. 5. Undo the two screws on the bracket. 6. Remove the differential pressure gage. 7. Unscrew the round cover and remove the cable (6.3 mm connector). Fig. 24 Removing the differential pressure gage 9.3.2 Installing Differential Pressure Gage To install the unit in the transmitter, reverse the procedure used to remove it. Check whether the protective cap for the air nozzle on the left-hand differential pressure gage has already been removed and if not, remove it (see figure). 2098.0188.72 - 8.32 - E-1 Chapter 8 Service Fig. 25 Differential pressure gage without protective cap Note After installation the differential pressure gage must be set to the switching point of 200 Pa again. 1. Remove the transparent top cover. In the middle is an adjuster with a scale. 2. Use a screwdriver to turn the adjuster until the arrow points to the value 200. 9.4 Replacing Temperature Sensors WARNING! Always make sure that the power supply is disconnected before commencing any service work on the transmitter rack. This will prevent injury due to electric shock and avoid damage to the instruments. The transmitter rack contains two temperatur sensors which measure the intake and outlet air temperatures. They are located on the intake and outlet lines on the rack. 9.4.1 Removing Temperature Sensor Note Prior to removal make sure which of the two temperature sensors needs to be replaced. 1. Using a Torx screwdriver No. 20, remove the rear panel of the rack. 2. Unplug the connector of the temperature sensor concerned. 2098.0188.72 - 8.33 - E-1 Chapter 8 Service Fig. 26 Removing the temperature sensor 3. Using a Phillips screwdriver No. 0, undo the two screws (M3) on the temperature sensor flange. 1) Openings for fixing screws (M3) 4. Carefully remove the temperature sensor from the aperture in the air duct. 9.4.2 Installing Temperature Sensor To install the unit in the transmitter, reverse the procedure used to remove it. 2098.0188.72 - 8.34 - E-1 Broadcasting Division Interface Description TRANSMITTER Printed in Germany 2095.7346.72 - 9.0 - D/E-1 Chapter 9 Annex CONTENTS 1 Interface Description ....................................................................... 1 1.1 Front-Panel Interfaces ....................................................................................1 1.1.1 Q1 – AC Supply Input / Protective Earth ......................................................1 1.1.2 X57 – Optional Connector Kit ZR800Z1 .......................................................1 1.1.3 X33 – External Fan (Optional): (Wago Plug-In Terminal) .............................1 1.1.4 X34 – AC Power Supply for Control Units and Exciters (Single-Phase): (Wago Plug-In Terminal) ..............................................................................2 1.1.5 X36 – External Absorber Cooling System (Optional): (Wago Plug-In Terminal) ..............................................................................2 1.1.6 X41 – RF Carrier Loop: (Wago Plug-In Terminal) ........................................3 1.1.7 X42 – Absorber Monitoring: (Wago Plug-In Terminal) .................................3 1.1.8 X43 – Cooling Monitoring: (Wago Plug-In Terminal) ....................................3 1.1.9 X44 – Overcurrent Monitoring for External Fan: (Wago Plug-In Terminal) ..4 1.2 Interfaces on the Transmitter Top ................................................................4 1.2.1 X100A – Ethernet A Remote (Standard): (8-Contact Female) .....................4 1.2.2 X100B – Ethernet B Remote (N+1 Option): (8-Contact Female) .................5 1.2.3 X232 – RS-232-C: (9-Contact D-Sub Female) .............................................5 1.2.4 X101A – CAN-Bus Rack Bus A: (9-Contact D-Sub Female) ........................6 1.2.5 X101B – CAN-Bus Rack Bus A: (9-Contact D-Sub Female) ........................6 1.2.6 X102A – ANTENNA 1: (N Female, 50 Ohm) ................................................7 1.2.7 X102B – ANTENNA 2: (N Female, 50 Ohm) ................................................7 1.2.8 X121A – TS1 Exciter A: (BNC Female, 75 Ohm) .........................................7 1.2.9 X121B – TS1 Exciter B: (BNC Female, 75 Ohm) .........................................7 1.2.10 X122A – TS2 Exciter A: (BNC Female, 75 Ohm) .........................................8 1.2.11 X122B – TS2 Exciter B: (BNC Female, 75 Ohm) .........................................8 1.2.12 X123A – TS3 Exciter A: (BNC Female, 75 Ohm) .........................................8 1.2.13 X123B – TS3 Exciter B: (BNC Female, 75 Ohm) .........................................8 1.2.14 X124A – TS4 Exciter A: (BNC Female, 75 Ohm) .........................................9 1.2.15 X124B – TS4 Exciter B: (BNC Female, 75 Ohm) .........................................9 1.2.16 X131A – TS1/2 IN Monitoring Exciter A: (BNC Female) ..............................9 1.2.17 X131B – TS1/2 IN Monitoring Exciter B: (BNC Female) ..............................9 1.2.18 X132A – TS3/4 IN Monitoring Exciter A: (BNC Female) ............................10 1.2.19 X132B – TS3/4 IN Monitoring Exciter B: (BNC Female) ............................10 1.2.20 X141A – 1PPS Exciter A: (BNC Female, 50 Ohm) ....................................10 2098.0188.72 - 9.01 - E-1 Chapter 9 Annex 1.2.21 X141B – 1PPS Exciter B: (BNC Female, 50 Ohm) ....................................10 1.2.22 X142A – 1PPS Monitoring Exciter A: (BNC Female, 50 Ohm) ..................11 1.2.23 X142B – 1PPS Monitoring Exciter B: (BNC Female, 50 Ohm) ..................11 1.2.24 X143A – 10 MHz REF.INPUT Exciter A: (BNC Female, 50 Ohm) .............11 1.2.25 X143B – 10 MHz REF.INPUT Exciter B: (BNC Female, 50 Ohm) .............11 1.2.26 RF Transmitter Output (EIA 1 5/8" Flange 50 Ohm ....................................12 1.3 Monitoring Outputs on Front Panel of R&S SV800 Exciter ......................12 1.3.1 X65A – 10 MHz Test Output for Exciter A: (SMA Female, 50 Ohm) ..........12 1.3.2 X65B – 10 MHz Test Output for Exciter B: (SMA Female, 50 Ohm) ..........12 1.3.3 X61A – RF Test Output for Exciter A: (SMA Female, 50 Ohm) .................12 1.3.4 X61B – RF Test Output for Exciter B: (SMA Female, 50 Ohm) .................13 2098.0188.72 - 9.02 - E-1 Chapter 9 Annex Interface Description 1.1 Front-Panel Interfaces 1.1.1 Q1 – AC Supply Input / Protective Earth 1.1.2 1.1.3 2098.0188.72 Signal name Direction Value range Contact Remark PHASE L1 Input 400 V ±15% Q1.T1 Three-phase current input L1 PHASE L2 Input 400 V ±15% Q1.T2 Three-phase current input L2 PHASE L3 Input 400 V ±15% Q1.T3 Three-phase current input L1 NEUTRAL N Input 0V Q1.N Neutral-conductor input N PROTECTION EARTH PE Input 0V X.PE PE terminal PROTECTION EARTH PE Input 0V PE pin PE station X57 – Optional Connector Kit ZR800Z1 Signal name Direction Value range Contact Remark PHASE L1 Input 230 V X57.L1 Separate circuit NEUTRAL N Input 0V X57.N PROTECTION EARTH PE Input 0V X57.PE X33 – External Fan (Optional): (Wago Plug-In Terminal) Signal name Direction Value range Contact Remark PHASE L1 Input 230 V X33.1 Line protection F8 [3A] NEUTRAL N Input 0V X33.2 - 9.1 - E-1 Chapter 9 Annex Signal name Direction Value range Contact PROTECTION EARTH PE Input 0V X33.3 Remark External fan for dummy antenna (optional): (Wago plug-in terminal) 1.1.4 1.1.5 2098.0188.72 Signal name Direction Value range Contact Remark PHASE L1 Input 230 V X33.4 Line protection F8 [3A] NEUTRAL N Input 0V X33.5 PROTECTION EARTH PE Input 0V X33.6 X34 – AC Power Supply for Control Units and Exciters (Single-Phase): (Wago Plug-In Terminal) Signal name Direction Value range Contact Remarks PHASE L1 Output 230 V X34.1 Line fuse F1 [3A] R&S NetCCU800 connection PHASE L1 Output 230 V X34.2 Line fuse F2 [3A] Sx800 A connection PHASE L1 Output 230 V X34.3 Line fuse F3 [3A] Sx800 B connection PHASE L1 Output 230 V X34.4 Line fuse F4 [3A] Add-on equipment connection NEUTRAL N Input 0V X34.5 PROTECTION EARTH PE Input 0V X34.6 X36 – External Absorber Cooling System (Optional): (Wago Plug-In Terminal) Signal name Direction Value range Contact Remarks PHASE L3 Output 230 V X36.1 Line fuse F8 [3A] - 9.2 - E-1 Chapter 9 1.1.6 1.1.7 1.1.8 2098.0188.72 Annex Signal name Direction Value range Contact NEUTRAL N Input 0V X36.2 PROTECTION EARTH PE Input 0V X36.3 Remarks X41 – RF Carrier Loop: (Wago Plug-In Terminal) Signal name Direction Value range Contact Remark MAIN TX LOOP Input -12 V ±2 V X41.1 -12 V floating LOOP COM (+) Output +12 V ±2 V X41.2 +12 V floating RESERVE TX LOOP Input -12 V ±2 V X41.3 -12 V floating LOOP COM (+) Output +12 V ±2 V X41.4 +12 V floating X42 – Absorber Monitoring: (Wago Plug-In Terminal) Signal name Direction Value range Contact Remark FAULT SYSTEM ABSORBER Input TTL X42.1 Jumper to 0 V REF RACK SIGNALS Output 0V X42.2 Reference 0 V FAULT RACK ABSORBER Input TTL X42.3 Jumper to 0 V REF RACK SIGNALS Output 0V X42.4 Reference 0 V X43 – Cooling Monitoring: (Wago Plug-In Terminal) Signal name Direction Value range Contact Remarks FAULT COOLING 2 Input TTL X43.1 Jumper against 0 V REF RACK SIGNALS Input 0V X43.2 Reference 0 V - 9.3 - E-1 Chapter 9 1.1.9 Annex Signal name Direction Value range Contact Remarks FAULT COOLING 1 Input TTL X43.3 Jumper against 0 V REF RACK SIGNALS Input 0V X43.4 Reference 0 V WARNING COOLING Input TTL X43.5 Jumper against 0 V REF RACK SIGNALS Input 0V X43.6 Reference 0 V X44 – Overcurrent Monitoring for External Fan: (Wago PlugIn Terminal) Signal name Direction Value range Contact Remark FAULT EXT: COOLING Input TTL X44.1 Jumper to 0 V REF RACK SIGNALS Output 0V X44.4 Reference 0 V 1.2 Interfaces on the Transmitter Top 1.2.1 X100A – Ethernet A Remote (Standard): (8-Contact Female) Signal name Direction Value range Contact Remark TX+ Output Ethernet X100A.1 Transmitting line TX- Output Ethernet X100A.2 Transmitting line RX+ Input Ethernet X100A.3 Receiving line Bidirect. 75 termination X100A.4 Bidirect. 75 termination X100A.5 Input Ethernet X100A.6 Bidirect. 75 termination X100A.7 RX- 2098.0188.72 - 9.4 - Receiving line E-1 Chapter 9 Signal name 1.2.2 Direction Value range Contact Bidirect. 75 termination X100A.8 Signal name Direction Value range Contact Remark TX+ Output Ethernet X100B.1 Transmitting line TX- Output Ethernet X100B.2 Transmitting line RX+ Input Ethernet X100B.3 Receiving line Bidirect. 75 termination X100B.4 Bidirect. 75 termination X100B.5 Input Ethernet X100B.6 Bidirect. 75 termination X100B.7 Bidirect. 75 termination X100B.8 Receiving line X232 – RS-232-C: (9-Contact D-Sub Female) Signal name Direction Value range n.c. Contact Remark X232.1 Transmitting line RS232_TX Output RS-232 X232.2 Transmitting line RS232_RX Input RS-232 X232.3 Receiving line n.c. GND 2098.0188.72 Remark X100B – Ethernet B Remote (N+1 Option): (8-Contact Female) RX- 1.2.3 Annex X232.4 Bidirect. X232.5 n.c. X232.6 n.c. X232.7 n.c. X232.8 - 9.5 - E-1 Chapter 9 1.2.4 1.2.5 2098.0188.72 Annex X101A – CAN-Bus Rack Bus A: (9-Contact D-Sub Female) Signal name Direction Value range Contact Remark 12V_RED Bidirect. 12 V ±1 V X101A.1 Redundant 12 V supply RC_A_CAN_L Bidirect. CAN-Level X101A.2 CAN bus signal CAN_GND Bidirect. 0V X101A.3 CAN GND 12V_RED Bidirect. 12 V ±1 V X101A.4 Redundant 12 V supply CAN_SHLD Bidirect. GND X101A.5 Shield GND Bidirect. GND X101A.6 GND RC_A_CAN_H Bidirect. CAN+Level X101A.7 CAN bus signal 12V_ASI Bidirect. 12 V ±1.5 V X101A.8 CAN_V+ Bidirect. 12 V ±1 V X101A.9 X101B – CAN-Bus Rack Bus A: (9-Contact D-Sub Female) Signal name Direction Value range Contact Remark 12V_RED Bidirect. 12 V ±1 V X101B.1 Redundant 12 V supply RC_A_CAN_L Bidirect. CAN-Level X101B.2 CAN bus signal CAN_GND Bidirect. 0V X101B.3 CAN GND 12V_RED Bidirect. 12 V ±1 V X101B.4 Redundant 12 V supply CAN_SHLD Bidirect. GND X101B.5 Shield GND Bidirect. GND X101B.6 GND RC_A_CAN_H Bidirect. CAN+Level X101B.7 CAN bus signal 12V_ASI Bidirect. 12 V ±1.5 V X101B.8 CAN_V+ Bidirect. 12 V ±1 V X101B.9 - 9.6 - E-1 Chapter 9 1.2.6 1.2.7 1.2.8 1.2.9 2098.0188.72 Annex X102A – ANTENNA 1: (N Female, 50 Ohm) Signal name Direction Value range Contact Remarks ANTENNA 1 Input > 80 dBV X102A.1 For DVB-T only Tx level depending on application GND Bidirect. 0V X102A.2 X102B – ANTENNA 2: (N Female, 50 Ohm) Signal name Direction Value range Contact Remarks ANTENNA 2 Input > 80 dBV X102B.1 For DVB-T only Tx level depending on application GND Bidirect. 0V X102B.2 X121A – TS1 Exciter A: (BNC Female, 75 Ohm) Signal name Direction Value range Contact Remark TS1 Input ASI/SMPTE310M X121A.1 TS1 Exciter A GND Bidirect. X121A.2 GND/shield X121B – TS1 Exciter B: (BNC Female, 75 Ohm) Signal name Direction Value range Contact Remark TS1 Input ASI/SMPTE310M X121B.1 TS1 Exciter B GND Bidirect. X121B.2 GND/shield - 9.7 - E-1 Chapter 9 1.2.10 1.2.11 1.2.12 Annex X122A – TS2 Exciter A: (BNC Female, 75 Ohm) Signal name Direction Value range Contact Remark TS2 Input ASI/SMPTE310M X122A.1 TS2 Exciter A GND Bidirect. X122A.2 GND/shield X122B – TS2 Exciter B: (BNC Female, 75 Ohm) Signal name Direction Value range Contact Remark TS2 Input ASI/SMPTE310M X122B.1 TS2 Exciter B GND Bidirect. X122B.2 GND/shield X123A – TS3 Exciter A: (BNC Female, 75 Ohm) Signal name Direction Value range Contact Remarks TS3 Input ASI X123A.1 Only for DVB-T with hierarchical coding TS3 Exciter A GND 1.2.13 Bidirect. X123A.2 GND/shield X123B – TS3 Exciter B: (BNC Female, 75 Ohm) Signal name Direction Value range Contact Remarks TS3 Input ASI X123B.1 Only for DVB-T with hierarchical coding TS3 Exciter B GND 2098.0188.72 Bidirect. X123B.2 - 9.8 - GND/shield E-1 Chapter 9 1.2.14 Annex X124A – TS4 Exciter A: (BNC Female, 75 Ohm) Signal name Direction Value range Contact Remarks TS4 Input ASI X124A.1 Only for DVB-T with hierarchical coding TS4 Exciter A GND 1.2.15 Bidirect. X124A.2 GND/shield X124B – TS4 Exciter B: (BNC Female, 75 Ohm) Signal name Direction Value range Contact Remarks TS4 Input ASI X124B.1 Only for DVB-T with hierarchical coding TS4 Exciter B GND 1.2.16 GND/shield Direction Value range Contact Remark TS1/2 IN Monitoring Output ASI/SMPTE310M X131A.1 TS1/2 Monitoring Exciter A GND Bidirect. X131A.2 GND/shield X131B – TS1/2 IN Monitoring Exciter B: (BNC Female) Signal name 2098.0188.72 X124B.2 X131A – TS1/2 IN Monitoring Exciter A: (BNC Female) Signal name 1.2.17 Bidirect. Direction Value range Contact Remark TS1/2 IN Monitoring Output ASI/SMPTE310M X131B.1 TS1/2 Monitoring Exciter B GND Bidirect. X131B.2 GND/shield - 9.9 - E-1 Chapter 9 1.2.18 Annex X132A – TS3/4 IN Monitoring Exciter A: (BNC Female) Signal name TS3/4 IN Monitoring Direction Value range Contact Remarks Output ASI X132A.1 Only for DVB-T with hierarchical coding TS3/4 Monitoring Exciter A GND 1.2.19 Bidirect. X132A.2 GND/shield X132B – TS3/4 IN Monitoring Exciter B: (BNC Female) Signal name TS3/4 IN Monitoring Direction Value range Contact Remarks Output ASI X132B.1 Only for DVB-T with hierarchical coding TS3/4 monitoring Exciter B GND 1.2.20 1.2.21 2098.0188.72 Bidirect. X132B.2 GND/shield X141A – 1PPS Exciter A: (BNC Female, 50 Ohm) Signal name Direction Value range Contact Remarks 1PPS_EXTERN Input TTL level (pos.edge) X141A.1 Second pulse from external GPS receiver (exciter A) GND Bidirect. X141A.2 GND/shield X141B – 1PPS Exciter B: (BNC Female, 50 Ohm) Signal name Direction Value range Contact Remarks 1PPS_EXTERN Input TTL level (pos.edge) X141B.1 Second pulse from external GPS receiver (exciter B) GND Bidirect. X141B.2 GND/shield - 9.10 - E-1 Chapter 9 1.2.22 1.2.23 1.2.24 1.2.25 2098.0188.72 Annex X142A – 1PPS Monitoring Exciter A: (BNC Female, 50 Ohm) Signal name Direction Value range Contact Remarks 1PPS Monitoring Output TTL level (pos.edge) X142A.1 Monitor output of internally used 1PPS (exciter A) GND Bidirect. X142A.2 GND/shield X142B – 1PPS Monitoring Exciter B: (BNC Female, 50 Ohm) Signal name Direction Value range Contact Remarks 1PPS Monitoring Output TTL level (pos.edge) X142B.1 Monitor output of internally used 1PPS (exciter B) GND Bidirect. X142B.2 GND/shield X143A – 10 MHz REF.INPUT Exciter A: (BNC Female, 50 Ohm) Signal name Direction Value range Contact Remark 10 MHz REF INPUT Input -5.0 dB to 20 dBm or TTL X143A.1 10 MHz reference for exciter A GND Bidirect. X142A.2 GND/shield X143B – 10 MHz REF.INPUT Exciter B: (BNC Female, 50 Ohm) Signal name Direction Value range Contact Remark 10 MHz REF INPUT Input -5.0 dB to 20 dBm or TTL X143B.1 10 MHz reference for exciter B GND Bidirect. X142B.2 GND/shield - 9.11 - E-1 Chapter 9 1.2.26 Annex RF Transmitter Output (EIA 1 5/8" Flange 50 Ohm Signal name Direction Value range Contact Remark RF transmitter output Output PmaxAVG = 1.8 kW RF RF transmitter output, fully equipped with 4 amplifiers GND Bidirect. RF GND/shield 1.3 Monitoring Outputs on Front Panel of R&S SV800 Exciter 1.3.1 X65A – 10 MHz Test Output for Exciter A: (SMA Female, 50 Ohm) 1.3.2 1.3.3 2098.0188.72 Signal name Direction Value range Contact Remarks 10MHz_REF_ OUT Output 0 dBm (+2 dB to -1 dB) X65A.1 10MHz reference monitoring for exciter A GND Bidirect. X65A.2 GND/shield X65B – 10 MHz Test Output for Exciter B: (SMA Female, 50 Ohm) Signal name Direction Value range Contact Remarks 10MHz_REF_ OUT Output 0 dBm (+2 dB to -1 dB) X65B.1 10MHz reference monitoring for exciter B GND Bidirect. X65B.2 GND/shield X61A – RF Test Output for Exciter A: (SMA Female, 50 Ohm) Signal name Direction Value range Contact Remarks RF_MONOUT Output -7dBm ±2dB X61A.1 RF OUT monitoring for exciter A - 9.12 - E-1 Chapter 9 1.3.4 2098.0188.72 Signal name Direction GND Bidirect. Value range Annex Contact Remarks X61A.2 GND/shield X61B – RF Test Output for Exciter B: (SMA Female, 50 Ohm) Signal name Direction Value range Contact Remarks RF_MONOUT Output -7dBm ±2dB X61B.1 RF OUT monitoring for exciter B GND Bidirect. X61B.2 GND/shield - 9.13 - E-1 Chapter 9 2098.0188.72 - 9.14 - Annex E-1 Broadcasting Division DATA SHEETS Printed in Germany 2098.7346.72 - 10.0 - E-1 Broadcasting Division System Manual Volume 2 R&S®NV830x DTV Transmitter ATSC Transmitter Series Nx8000 Only skilled personnel may perform the operations of the described instrument that are necessary for installing and putting it into operation as well as maintaining, troubleshooting and servicing it. Printed in Germany 2098.0188.72 -01 - 2.1 - System Manual Transmitter Series Nx8000 Edition: August 2009 Version: E 01.00 © 2009 Rohde&Schwarz GmbH & Co. KG 81671 Munich, Germany This document may be duplicated or otherwise used or its contents made known to third parties only with permission of the originator or other authorized persons. Infringements constitute an offence and are subject to claim for damages (UrhG, UWG, BGB). All rights reserved for patenting or utility model registration. The R&S logo, Rohde & Schwarz and R&S are registered trademarks of Rohde & Schwarz GmbH & Co.KG and their subsidiaries. ROHDE & SCHWARZ GmbH & Co.KG D-81671 München - Mühldorfstraße 15 Telefon: (089) 4129-0 ^ Int. +49894129-0 Telefax: (089) 4129-12164 Internet: www.rohde-schwarz.com Printed in Federal Republic of Germany ^ Subject to change ^ Data without tolerances: typical values 2098.0188.72 -01 - 2.2 - NV830XE/V CONTENTS DRAWINGS AND DIAGRAMS NV8301 DRAWINGS AND DIAGRAMS NV8302 DRAWINGS AND DIAGRAMS NV8303 DRAWINGS AND DIAGRAMS NV8304 SPARE PARTS LISTS 2098.0188.72 - 2.3 - E-1 Broadcasting Division Drawings and Diagrams NV8301E/V 2098.0307.01 Printed in Germany 2098.0188.72 -1- E-1 E X121A W21A X20 TS2 input 260mVpp...2Vpp 75 X122A W22A X21 TS3 input 260mVpp...2Vpp 75 X123A W23A X25 X124A TS 1/2 monitoring 800mVpp -+30% 75 X131A TS 3/4 monitoring 800mVpp -+30% 75 X132A 1PPS EXTERNAL input 50 X141A 1PPS monitoring 75 X142A 10 MHz REF input -5...20dBm 50 X143A W24A X26 11 12 13 14 15 16 A100A SX800 TV EXCITER 2095.1502.xx RF OUTPUT W32A X60 X27 W41A X24 W42A W43A X67 1.RF DEMOD IN X68 E) V) W300A1 E) X1 V)R15A X4 A1 VH8300A1 UHF-VERSTAERKER RF SWITCH IN POSITION 2 W300 X2 X307 X.A1 W307A UHF AMPLIFIER X10 A45 X3 W.A1 X2 V)W304 V)A15 HF-SCHALTER TS2 input 260mVpp...2Vpp 75 X122B TS3 input 260mVpp...2Vpp 75 X123B TS4 input 260mVpp...2Vpp 75 X124B TS 1/2 monitoring 800mVpp -+30% 75 X131B V) W31B X22 TS 3/4 monitoring 800mVpp -+30% 75 X132B V) W32B X27 1PPS EXTERNAL input 50 X141B X20 V) W22B X21 V) W23B X25 X26 V) W24B V) W41B 2096.6508.01 OBERWELLENFILTER HARMONICS FILTER V) W42B X24 2.RF DEMOD IN V) W43B ak= dB P14D P14C FILTER DIRECTIONAL COUPLER W2ADE E) X67 E) W3ADE E) V) X68 E) W4ADE E) V) RF OUTPUT OR INSTALLED BY CUSTOMER V) W300B1 E) HF-AUSGANG O) OPTION ODER INSTALLATION VOM KUNDEN 2096.7204.xx W1ADE MESSRICHTKOPPLER E) OPTION ADE AUTOMAT. ENTZERRUNG ADE SYSTEM KIT SX800Z1 2099.4006.01 V) OPTION VORSTUFEN SATZ SX800 ZR800V1 2099.1507.01 EXCITER STANDBY INSTALL KIT E) V) HIERZU SIEHE AUCH: 2098.5009.01 SA (ZR800C1) see also: 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) E) V) HF-BLOCKSCHALTBILD GUELTIG FUER VAR: SIEHE SCHALTTEILLISTE VALIED FOR MODELS: SEE PARTS LIST BLOCK DIAGRAM OF RF SIGNAL Benennung / Designat.: ROHDE&SCHWARZ NV8301X NV8301X BLITZSCHUTZ E) P14 GD800 X64 O) XMTR RF OUTPUT ak=+)dB ak=+)dB E) X23 1.RF DEMOD IN HF-SENDER AUFGANG P14B P14A ak= dB V)W300B1 X60 RF OUTPUT X.A X3 V) A100B SX800 TV EXCITER 2095.1502.xx O) MESSRICHTKOPPLER DIRECTIONAL COUPLER HF-SCHALTER IN POS:2 X64 V) W21B P24 DACH TOP X23 X121B 10 MHz REF input -5...20dBm 50 BLATT 6: STROMLAUF NETZKABEL sheet 6: circuit diagram power cable COUPLING ATTENUATION P14 SEE ALSO SYSTEM MANUAL 2095.3257.xx X143B BLATT 5: STROMLAUF STEUERKABEL sheet 5: circuit diagram signal cable +)AUSKOPPELDAEMPFUNG P14 SIEHE SYSTEM-HANDBUCH W300 RF SWITCH 1PPS monitoring 75 BLATT 4: BLOCKSCHALTBILD STEUERLEITUNG sheet 4: block diagram of signal V) W300A1 2.RF DEMOD IN X142B 17 BLATT 3: NETZ-STROMLAUF MIT USV sheet 3: circuit diagram with UPS X22 W31A TS1 input 260mVpp...2Vpp 75 10 BLATT 2: NETZ-STROMLAUF sheet 2: circuit diagram V) EXCITER B DACH TOP 50 OHM 50 OHM ak= 60 dB 50 OHM Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved BLATT 1: HF-BLOCKSCHALTBILD sheet 1: block diagram of rf signal TS1 input 260mVpp...2Vpp 75 TS4 input 260mVpp...2Vpp 75 ak= 60 dB EXCITER A OPTION 10 11 12 13 NV8301X 14 Datum: Date: 08/07/18 DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 1+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0307.01 S 16 17 Q1 W3 W2 W1 L1 L2 L3 W.PE X20.1-3 W4 16 17 +12V A31 NETZVERTEILUNG MITTELLEISTUNG Main distribution MP K1 1 K2 1 K3 1 NC NC GND GND 21 22 23 24 18 25 14 15 16 17 12 GND GND GND GND X45.2 11 GND GND +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS CL_DL_ON_OFF COOLING_ON_OFF X45.1 F1 +12V 10 13 19 20 LOOP+_RESERVE LOOP-_COM LOOP+_MAIN FAULT2_ABS FAULT1_ABS 0V PRES 2 PRES 1 + 5V FAULT2_CL FAULT1_CL X44. WARNING_CL X10 OVERCUR_EXT_CL NICHT BELEGT NC X43. + 12V GND + 5V X42. GND X43B PRES 2 LINK + 5V LINK GND LINK 15 GESTELLSTEUERUNG / Rack controller OPTION LUFTMAENGEN-MESSUNG air quantity measurement PRES 1 LINK 14 +12V X.PE1 LINK 13 +12V 12 +12V T1 T2 T3 11 UEBERSTROM EXT KUEHLUNG overcurrent ext.cooling EXTERNAL POWER KIT X41. L N PE 10 RF LOOP SCHUTZSCHLEIFE Z1) OPTION ZR800Z1 2099.3000.xx BAUSATZ STECKDOSE EXTERN #) Z1) X57 NICHT BELEGT not connected PE STOERUNG KUEHLUNG 1 fault cooling 1 L1 L2 L3 N NETZSTECKDOSE AC supply connector 230V AC max. 10A min.3x1qmm STOERUNG KUEHLUNG 2 fault cooling 2 230/400V AC BETRIEBSERDE system ground STOERUNG GESTELL ABS fault rack abs 2098.0342.xx STOERUNG ANLAGEN ABS fault system abs VORSICHERUNG UND ANSCHLUSSQUERSCHNITT SIEHE SYSTEM-HANDBUCH NV8301E/V External fuseing and cable cross-sections see system manual NV8301E/V RESERVESENDER standby xmitter BETRIEBSSENDER main xmitter 2096.3009.xx L1 L2 L3 X1. X2. L1 W.L1 L2 W.L2 L3 W.L3 Q3X Q2X Q2 X20.1 F6 3A 2 F7 3A 2 F8 3A 2 F5 3A 2 F1 3A 2 F2 3A 2 F3 3A 2 F4 3A 2 X6 X7 X8 X5 X1 X2 X3 X4 W4 X.N1 I>> I>> I>> X20.1 L2 X31. W31 W61 X61 U1 V1 W1 3 4 5 6 7 A1 VH8300A1 UHF-VERSTAERKER C1A 8u E1 UHF AMPLIFIER X1. XE1.1 2 K1 LUEFTER FAN 2096.2131.xx L3 X32. W32 XE2.1 2 K1 C2A 8u L3 X33. K2 L3 #) E2 LUEFTER FAN 2096.2131.xx L3 X36. #) 3 4 5 6 7 K3 #) OPTION STEUERBEFEHL FUER EXTERNE KUEHLUNG EIN control command for OPTION external cooling on STEUERBEFEHL FUER KUNSTANTENNE EIN control command for dummy load on OPTION NETZANSCHLUSS FUER EXTERNEN ABS - LUEFTER AC supply for external ABS cooling L1 X35. 1 2 W35 X45. 1 2 2096.3550.xx L1 L1 L1 L1 X34.1 W60 X52.52 53 54 55 71 81 X52.62 72 82 +12V Vout + Vout + W62C GND Vout Vout - A 36 NETZTEIL POWER SUPPLY 1081.0254.00 63 73 83 A200 NETCCU 800 A100A EXCITER A 10 11 12 PE Z2) OPTION ZR800Z2 2099.3100.xx BAUSATZ STECKDOSE INTERN A100B EXCITER B HIERZU SIEHE AUCH: 2098.5009.01 SA (ZR800C1) see also: 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) INTERN POWER POINT KIT V) OPTION ZR800V1 2099.1507.xx VORSTUFEN SATZ SX800 EXCITER STANDBY INSTALL KIT PE L N PE L N PE Z2) X55Z NV8301X 14 Datum: Date: 08/07/18 NETZ-STROMLAUF GUELTIG FUER VAR: SIEHE SCHALTTEILLISTE VALIED FOR MODELS: SEE PARTS LIST Benennung / Designat.: ROHDE&SCHWARZ NV8301X NV8301X 13 W155Z NETZANSCHLUSS FUER ZUSATZGERAETE AC supply for additional units V) W62B W62A 65 75 85 64 74 84 #) INSTALLATION VOM KUNDEN #) installed by customer A35 VERTEILER-N-NETZ Interface Power N Distribution X.PE W45 ACL ACN X.N3 X.N2 GND +12V X10.25 X10.18 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved W3PH DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK CIRCUIT DIAGRAM Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 2+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0307.01 S 16 17 Q1 W3 W2 W1 L1 L2 L3 W.PE 13 X20.1-3 W4 W1PH 23 W.N3 Z5) F1 L N PE 10 12 11 +12V K3 1 NC NC 21 22 23 24 18 25 14 15 16 17 K1 1 K2 1 GND GND GND GND +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS CL_DL_ON_OFF COOLING_ON_OFF LOOP+_RESERVE 13 19 20 LOOP-_COM LOOP+_MAIN FAULT2_ABS FAULT1_ABS FAULT2_CL 0V PRES 2 PRES 1 + 5V FAULT1_CL WARNING_CL X44. X10 OVERCUR_EXT_CL NICHT BELEGT NC + 12V X43. GND + 5V GND X42. PRES 2 X43B + 5V LINK GESTELLSTEUERUNG / Rack controller OPTION LUFTMAENGEN-MESSUNG air quantity measurement GND GND GND GND X45.2 A31 NETZVERTEILUNG MITTELLEISTUNG Main distribution MP LINK 17 X45.1 X.PE2 LINK 16 +12V 24 LINK X41. #) Z1) X57 LINK 15 +12V X.PE1 EXTERNAL POWER KIT 14 +12V RF LOOP SCHUTZSCHLEIFE 13 +12V T1 T2 T3 Z5) Q1.1 14 12 GND #) 11 PRES 1 #) 10 UEBERSTROM EXT KUEHLUNG overcurrent ext.cooling PE NICHT BELEGT not connected L1 L2 L3 N Z1) OPTION ZR800Z1 2099.3000.xx BAUSATZ STECKDOSE EXTERN NETZSTECKDOSE AC supply connector 230V AC max. 10A min.3x1qmm UPGRADE KIT EXTERNAL UPS STOERUNG KUEHLUNG 1 fault cooling 1 230/400V AC BETRIEBSERDE system ground Z5) OPTION ZR800Z5 2099.3400.xx BAUSATZ EXTERNE USV STOERUNG KUEHLUNG 2 fault cooling 2 2098.0342.xx ACHTUNG !/ CAUTION ! NETZVERSORGUNG VON EXTERNER USV POWER SUPPLY FROM EXTERNAL UPS 230 AC max. 5A N PE STOERUNG GESTELL ABS fault rack abs VORSICHERUNG UND ANSCHLUSSQUERSCHNITT SIEHE SYSTEM-HANDBUCH NV8301E/V External fuseing and cable cross-sections see system manual NV8301E/V STOERUNG ANLAGEN ABS fault system abs RESERVESENDER standby xmitter BETRIEBSSENDER main xmitter 2096.3009.xx L1 L2 L3 X2. X1. L2 W.L2 L3 W.L3 Q3X Q2X Q2 F7 3A 2 F8 3A 2 F5 3A 2 F1 3A 2 F2 3A 2 F3 3A 2 F4 3A 2 X6 X7 X8 X5 X1 X2 X3 X4 I>> I>> I>> X20.1 X61 C1A 8u X1. XE1.1 2 U1 V1 W1 3 4 5 6 7 A1 VH8300A1 UHF-VERSTAERKER E1 UHF AMPLIFIER LUEFTER FAN 2096.2131.xx K1 L2 X31. W31 W61 K1 L3 X32. W32 C2A 8u XE2.1 2 L3 X33. K2 #) E2 LUEFTER FAN 2096.2131.xx L3 L3 X36. #) 3 4 5 6 7 K3 #) OPTION STEUERBEFEHL FUER EXTERNE KUEHLUNG EIN control command for OPTION external cooling on STEUERBEFEHL FUER KUNSTANTENNE EIN control command for dummy load on OPTION NETZANSCHLUSS FUER EXTERNEN ABS - LUEFTER AC supply for external ABS cooling L N3 X35. 1 2 W35 W45 ACL ACN W60 X52.52 Vout + Vout + W62C GND Vout Vout - A 36 X34.1 +12V NETZTEIL POWER SUPPLY 1081.0254.00 10 A35 VERTEILER-N-NETZ Interface Power N Distribution X.PE N3 54 63 73 83 A200 NETCCU 800 11 A100A EXCITER A 12 Z2) OPTION ZR800Z2 2099.3100.xx BAUSATZ STECKDOSE INTERN V) V) OPTION ZR800V1 2099.1507.xx VORSTUFEN SATZ SX800 EXCITER B 13 EXCITER STANDBY INSTALL KIT W155Z NETZANSCHLUSS FUER ZUSATZGERAETE AC supply for additional units A100B HIERZU SIEHE AUCH: 2098.5009.01 SA (ZR800C1) see also: 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) INTERN POWER POINT KIT 65 75 85 64 74 84 PE 55 71 81 V) W62B W62A #) INSTALLATION VOM KUNDEN #) installed by customer X.N3 L N3 53 X52.62 72 82 X.N2 2096.3550.xx X45. 1 2 X.N1 X20.1 GND +12V X10.25 Z5) W.N3 W4 F6 3A 2 X10.18 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved W3PH PE L N PE L N PE Z2) X55Z DARSTELLUNG MIT NETZVERSORGUNG VON EXTERNER USV DESCRIPTION FOR POWER SUPPLY FROM EXTERNAL UPS ROHDE&SCHWARZ NV8301X NV8301X 14 Datum: Date: CIRCUIT DIAGRAM VALIED FOR MODELS: SEE PARTS LIST Benennung / Designat.: NV8301X NETZ-STROMLAUF GUELTIG FUER VAR: SIEHE SCHALTTEILLISTE 08/07/18 DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 3+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0307.01 S 16 17 1 10 11 12 TV STEUERSENDER X9 .1 .1 W59 X10 .9 .8 .1 X53A .1 CAN BUS ABSCHLUSSWIDERST. W56A X3 .8 .1 TERMINATING RESISTOR 2097.5628.00 .1 *) RS232 W47 .9 X7 X5 ETHERNET .8 A200 .1 TX CONTROL .9 .1 W55 ETHERNET B X12 .25 .1 X11 .15 X12 BLINDSTECKER ASI DISTRIBUTOR 2094.0260.xx .9 X4 .1 X10 .1 .9 V) W56B V) W70 .9 .1 X2 .8 2095.3257xx .15 3562.4210.xx .1 2099.1507.01 .1 EXTERNE PUMPE .1 X4 .15 TON VERSTAERKER .9 .1 W53D .15 CAN 3 NICHT BELEGT EXTERNAL PUMP NOT CONNECTED HF-MESSSTELLEN RF PROBES NICHT BELEGT NOT CONNECTED X9 .1 .9 X6 W52 2096.3550.xx 2095.1502.xx X43 .1 .2 W51B S.E2 DRUCKDOSE PRESSURE BOX 2077.3936.xx .3 .4 X41. 1 2 3 4 X42. 1 2 3 4 W45 Bruecke / Link .1 W51B .3 Bruecke / Link ABSORBER SCHUTZSCHLEIFE RF LOOP UEBERSTROM EXTERNE KUEHLUNG OVER CURRENT EXTERNAL COOLING PRESSURE BOX 2077.3936.xx .1 W51A .3 HIERZU SIEHE AUCH: see also: 2098.5009.01 SA (ZR800C1) 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) .1 X.Vout .4 Bruecke / Link A36 NETZTEIL POWER SUPPLY 1081.0254.00 see sheet 2,3 S.E1 DRUCKDOSE .1 X45 .4 X44. 1 2 W51A siehe Blatt 2,3 X10 .25 .1 .9 TV EXCITER X8 .25 .1 INTERFACE POWER N DISTRIBUTION ONLY BY SINGLE EXCITER 2096.4505.xx TV STEUERSENDER 2095.3305.xx 2097.5605.00 VERTEILER-N-NETZ E) NUR BEI EINZEL-VORSTUFE TERMINATING RESISTOR A35 EXCITER RF SWITCH FOR ADE EXCITER STANDBY INSTALL KIT X11 A50 V) A100B SX800 VORST.SCHALTER FUER ADE V) ZR800V1 VORSTUFEN SATZ SX800 .15 X53D CAN BUS ABSCHLUSSWIDERST. 2097.5611.00 GESTELLSTEUERUNG .1 .1 V) A15 VORST.SCHALTER X5 PARALLEL REMOTE INTERFACE X53B CAN BUS ABSCHLUSSWIDERST. CAN 2 CAN 1 2095.6004.01 TERMINATING RESISTOR W50 ETHERNET EXCITER RF SWITCH .20 W53D V) W54B 2097.5657.00 F) ZR800F1 PARALLELE-FERNSCHNITT-STELLE W50 .1 SOUND AMPLIFIER .1 X7 .9 .1 E) X54B .9 .1 X7 .9 .8 DUMMY PLUG *) OPTION .1 X11B .9 W50 W58AB X6 UHF AMPLIFIER RACK CONTROLLER 2095.8007.xx .1 2010.0006.xx .9 .9 VITIATED AIR SENSOR .9 W58B A1 VH8300A1 UHF-VERSTAERKER .20 .1 .9 .15 .1 A60B ASI VERTEILER W54A W55 .9 W55 X6 .1 NETCCU 800 X6 X100A .8 X232 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved ETHERNET REMOTE .1 .1 W48 2094.0260.xx X2 X2 .1 .9 .9 B2 ABLUFT SENSOR ETHERNET ETHERNET A .1 W50 X3 2096.6308.xx .9 DACH TOP ASI DISTRIBUTOR .9 X2 RF REFLECTED ANT. W59 X2 W57 X5 3562.3707.xx GD800Z2 P14B HF-RUECKLAUF ANT. 2095.1502.xx .1 X53A REMOTE INTERFACE 2010.0006.xx W58A TV EXCITER X1 F) ZR800F1 .1 A57 FERNSCHNITTSTELLE INCOMING AIR SENSOR .1 A60A ASI VERTEILER X53D .9 X11 .9 .1 A100A SX800 .1 X2 2096.6308.xx TERMINATING RESISTOR W59 B1 ZULUFT SENSOR X2 2097.5628.00 RF FORWARD ANTENNA .1 X1 GD800Z2 P14A HF-VORLAUF ANT. X1 X53A CAN BUS ABSCHLUSSWIDERST. X11 .1 W53D ROHDE&SCHWARZ NV8301X NV8301X NV8301X Datum: Date: 08/07/18 BLOCKSCHALTBILD STEUERLEITUNG BLOCK DIAGRAM OF SIGNAL Benennung / Designat.: DTV-SENDER DTV XMTR Abteilung: Dept.: 10 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 4+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 11 2098.0307.01 S 12 1 X12 X53A 2097.5657.00 NETCCU 800 CAN_L 2 X12. SWI1_OS_POS_II 15 GND 16 BRUECKE SWI1_OS_PL 24 GND 25 BRUECKE X41 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved RF LOOP BETRIEBSSENDER MAIN XMITTER BRUECKE LINK NC R35B TX TX RX RX NC CAN_L 6 VERTEILER-N-NETZ X42. ABSORBER STOERUNG FAULT ABSORBER FAULT2_ABS 1 GND_0V 2 ANLAGE SYSTEM CAN_H 14 15 gn ge +12V +12V GND GND 4055.6458.00 ETHERNET REMOTE ASI VERTEILER A ASI DISTRIBUTOR A X11B. #) #) #) #) #)Bruecke auf GS X100A. X5. RACK CONTROLL UNIT 1 TX + 2 TX 3 RX + 6 RX - #) Link on PCB A60A X2. RACK NC X54B W53D 2097.5592.00 REDUCED_REF_B INTERFACE POWER DISTRIB. A35 X44. OVERCURRENT 1 _EXT_CL GND_0V 2 BRUECKE LINK UEBERSTROM EXT. KUEHLUNG GND A35 X10. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 W51AB 2097.5463.00 10 11 12 13 14 15 VERTEILER-NETZ BRUECKE INTERF: POWER DISTRIB. LINK A50 X3. A35 X43. W51B FAULT2_CL 1 GND_0V 2 WARNING_CL 6 GND_0V 7 W51A DRUCKDOSE PRESSURE BOX S.E2 S.E1 N.C. N.C. OVERCU_EXT_CL WARNING_CL FAULT1_CL FAULT2_CL FAULT1_ABS FAULT2_ABS LOOP+_MAIN LOOP_COM LOOP+_RESERVE GND_0V COOLING_ON_OFF CL_DL_ON_OFF +5V +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS SENSE+ PRES1 PERES2 GND GND GND GND SENSE- 13 W55 RACK CONTROLL UNIT 10 11 12 13 14 15 10 11 12 13 14 15 10 11 12 13 14 15 10 11 12 13 14 15 X6. X6. W54B +12V_RC N.C. GND LOOP-_EXC_A REDUCED_REF_A GND N.C. LOOP+_EXC_A +12V_RC A200 X7. 2097.5405.00 GESTELLSTEUERUNG SX800B EXCITER B RACK CONTROLL UNIT A100B A50 X7. X6. +12V_RC N.C. GND LOOP-_EXC_B REDUCED_REF_B GND N.C. LOOP+_EXC_B +12V_RC TX TX RX RX W56B A100B X2. RX RX TX TX 2097.5428.00 A50 X10. W58B W59 /SWI_EXC_POS1_A GND /SWI_EXC_SELECT2_B /SWI_EXC_POS2_B /SWI_EXC_SELECT3_B /SWI_EXC_POS3_B GND /SWI_EXC_SELECT1_B /SWI_EXC_POS1_B /SWI_EXC_SELECT2_A /SWI_EXC_POS2_A /SWI_EXC_SELECT3_A /SWI_EXC_POS3_A +12V_SWI_EXC NETCCU 800 A200 X10. B1.ZU B2.AB 2097.5457.00 HF-VORLAUF ANT. RF FORWARD ANTENNA P14A X1. HF-RUECKLAUF ANT. RF REFLECTED ANTENNA GND PEAK/AV1 +12V N.C. N.C. RF_PROBE1 ADJUST1 N.C. N.C. P14B X1. N.C. N.C. +12V PEAK/AV2 GND N.C. N.C. ADJUST2 RF_PROBE2 STROMLAUF DER STEUER-KABEL CIRCUIT DIAGRAM FROM THE SIGNAL CABLE ROHDE&SCHWARZ NV8301X NV8301X 13 10 11 12 13 14 15 Benennung / Designat.: 12 A15 X5. TEMPERATURE MONITOR *) OPTION 11 EXCITER RF SWITCH TEMPERATURFUEHLER W58A TV EXITER B A200 X4. TX TX RX RX N.C. CAN-L CAN_GND N.C. N.C. GND CAN-H N.C. CAN_V+ VORSTUFEN-SCHALTER RACK CONTROLL UNIT SX800 B ETHERNET B 17 2097.5370.00 10 11 12 13 14 15 X9. GESTELLSTEUERUNG 1139.2247.00 NETCCU 800 TX TX RX RX GND DGND AGND /AMPL_ERR RESET AMPL_ON VREF_PWR PEAK_AV PWR_OUT CAN_GND CAN_L CAN_H CAN_V+ /AC_OK NC SX800 A A200 X11. A200 W58AB A100A X2. NETCCU 800 TV EXITER A A200 X3. NETCCU 800 X1. +12V_RED CAN1_L CAN_GND +12V_RED CAN_SHLD GND CAN1_H +12V_ASI CAN_V+ 0041.9283.00 ETHERNET A W70 A57 A50 X2. NETCCU 800 X53D. 10 X53A. 16 *) 3562.3765.00 REMOTE INTERFACE GESTELLSTEUERUNG CAN BUS ABSCHL. RACK CONTROLL UNIT CAN BUS TERMINATING W56A CAN-Bus 10 11 12 13 14 15 W57 2097.5411.00 NETCCU 800 A50 A100A 15 FERNSCHNITTSTELLE UHF AMPLIFIER 10 11 12 13 14 15 14 GESTELLSTEUERUNG SX800A UHF-VERSTAERKER A3 A2 A5 A6 A1 A4 X11. X11. X11. X11. X11. X11. 10 11 12 13 14 15 12 2097.5392.00 EXCITER A 2097.5357.00 RACK CONTROLL UNIT OVERCURRENT EXT. COOLING INTERFACE POWER DISTRIBUTION GESTELLSTEUERUNG FAULT1_CL 3 20 120 OHM A50 X7. VERTEILER-N-NETZ +12V +12V R35D RACK CONTROLL UNIT 2097.5634.44 ASI 3 ASI 4 TERMINATING RESISTOR GESTELLSTEUERUNG X44 W54A VERTEILER-NETZ 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 20 LINK GESTELL A50 X8. A60B X2. 1 ASI 1 2 ASI 2 5 +12V 6 +12V 7 ASI 3 8 ASI 4 10 11 +12V 12 +12V 13 BRUECKE FAULT1_ABS 3 GND_0V 4 RACK CONTROLL UNIT ASI VERTEILER B ASI DISTRIBUTOR B 11 2097.5363.00 GESTELLSTEUERUNG CAN-BUS ABSCHLUSS-WIDERSTAND NC 10 W52 *) 2097.5386.00 GESTELLSTEUERUNG A50 X11. 2097.5605.00 X53D. 2097.5634.42 A36 X.P2 bn A200 TERMINATING RESISTOR X53D ETHERNET 120 OHM CAN_H 14 15 POWER SUPPLY NETCCU 800 STANDBY XMITTER INTERFACE POWER DISTRIB. CAN_L 6 CAN-BUS ABSCHLUSS-WIDERSTAND W50 NETZTEIL ws W48 2097.5611.00 RESERVESENDER A35 N.C. N.C. +12V GND NC X53B. SCHUTZSCHLEIFE X41. X42 A35 X45. 120 OHM 2096.3444.00 INTERFACE POWER N DISTRIB. TERMINATING RESISTOR X53B VERTEILER-N-NETZ LINK VERTEILER-N-NETZ LOOP-_RESER.3 LOOP_COM NC W45 R35A CAN_H 7 2097.5634.41 LOOP+_MAIN 1 LOOP_COM CAN-BUS ABSCHLUSS-WIDERSTAND LINK INTERFACE POWER DISTRIB. A35 2097.5628.00 X53A. TX CONTROL A200 NV8301X 14 Datum: Date: 08/07/18 DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 5+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0307.01 S 16 17 1 X33 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved INTERFACE POWER DISTRIB. A35 X31. L2 1 N 2 PE 3 230V AC X36. A35 X32. L3 1 N 2 PE 3 *) LINK AT PLUG INTERFACE POWER DISTRIB. A35 X34. X.E1 2 L2 4 N 7 PE C1A 8 L1 L1 L1 L1 PE E2 FAN CONNECTION bl/2 gnge 2 L3 4 N 7 PE C2A 8 NETZVERTEILUNG POWER DISTRIBUTION A31 Q2-Q7. X20.1-3 E1 FAN CONNECTION bl L2 2 N 4 PE 7 E2 W35 FAN *) o) E1 2096.3450.00 VERTEILER-NETZ A35 X35. sw *) bn L1 1 N 2 PE 3 gnge A200 NETCCU bn/1 bl/2 gnge W155Z 1 L1 2 N.C. 3 N PE A100B W62B SX800 B 2096.2131.01 E2 LUEFTERANSCHLUSS SX800 B TV EXCITER B AC VERTEILUNG ZUSATZGERAETE A100B X1. AC POWER DISTRIBUTION ADDITIONAL UNITS X52. bn/1 64 74 84 L1 PE bl/2 gnge 2097.5086.00 AC VERSORGUNG VERSTAERKER AC POWER SUPPLY AMPLIFIER A1-A6 X1. sw/1 W62C 1 L1 3 L2 4 L3 PE bl/2 bn/3 gnge 2097.4921.00 NETCCU 800 AC VERTEILUNG A200 X1. AC POWER DISTRIBUTION X52. bn/1 62 72 82 L1 PE bl/2 gnge 2097.5028.00 NETZANSCHLUSS FUER ZUSATZGERAETE AC VERTEILUNG 65 75 85 2097.4944.00 BIS / TO AC POWER DISTRIBUTION X52. gnge SX800 A POWER SUPPLY A36 X.P1 L1 PE bl/2 A100A NETZTEIL INTERFACE POWER DISTRIB. A100A X1. bn/1 63 73 83 2097.5034.00 W61-W66 E1 LUEFTERANSCHLUSS LUEFTER X52. X.E2 bn/1 SX800 A TV EXCITER A AC POWER DISTRIBUTION AC VERTEILUNG 2097.4938.00 AC VERTEILUNG AC POWER DISTRIBUTION 62 72 82 63 73 83 64 74 84 65 75 85 E2 LUEFTERANSCHLUSS 2096.2131.01 X.E1 52 53 54 55 71 81 X52. W62A 2097.4950.00 2096.3438.00 INTERFACE POWER DISTRIB. *) BRUECKE AM STECKER E1 gnge VERTEILER-NETZ E1 FAN CONNECTION bl/2 VERTEILER-NETZ NETZANSCHLUSS L3 1 EXT.ABS LUEFTER N 2 AC SUPPLY FOR PE 3 EXT. ABS COOLING W60 E1 LUEFTERANSCHLUSS bn/1 W32 2097.5634.36 2096.3421.00 VERTEILER-NETZ 230V AC STEUERBEFEHL L3 1 KUNSTANTENNE EIN N 2 CONTROL COMMAND PE 3 DUMMY LOAD ON X36 W31 2097.5634.33 X33. L3 1 STEUERBEFEHL EXT.KUEHLUNG EIN N 2 CONTROL COMMAND PE 3 EXT.COOLING ON AC SUPPLY FOR ADDITIONAL UNITS bn/1 L1 PE bl/2 gnge E2 FAN CONNECTION X.E2 L2 2 N 4 PE 7 LUEFTER bl FAN *) o) E2 STROMLAUF DER NETZ-KABEL sw CIRCUIT DIAGRAM FROM THE POWER CABLE *) bn Spr.:/Lang.: Aei:/C.I.: Benennung / Designat.: ROHDE&SCHWARZ NV8301X NV8301X gnge NV8301X Datum: Date: 08/07/18 DTV-SENDER DTV XMTR Abteilung: Dept.: 7TSK de 02.00 Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a Blatt:/Sh.: 6- 2098.0307.01 S el.Kennz Part Benennung / Hinweise Designation Sachnummer Stock No. Hersteller Manufacturer Bestellbezeichnung Designation enthalten in contained in ACHTUNG EGB /ATTENTION ESD Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision *VARIANTENERKLAERUNG *EXPLANATION OF MODELS VAR04=NV8301E DTV-SENDER MIT EINZEL-VORSTUFE PROGNOSESENDER MOD04=NV8301E DTVTRANSMITTER WITH SINGLE EXCITER VAR24=NV8301V DTV-SENDER MIT VORSTUFE-RESERVE OHNE ADE PROGNOSESENDER MOD24=NV8301V DTV TRANSMITTER WITH DUAL DRIVE WITHOUT ADE VAR50=NV8301X DTV-SENDER +++GRUNDSENDER+++ MOD50=NV8301X DTVTRANSMITTER ++BASIC TRANSMITTER++ A1 GG VH8300A1 UHF-VERSTAER. 3Phasig VH8300A1 UHF-AMPLIFIER VAR 04 24 2095.6004.02 2098.0307.01 A20 GS ZR800T1 EINBAUS. SX800 ZR800T1 INSTAL. KIT VAR 04 24 DTV - Ausfuehrung 2099.1007.03 2098.0307.01 A21 GS ZR800C1 LEISTUNGSSATZ ZR800C1 POWER KIT VAR 04 24 Leistungssatz fuer 1 Verstaerker 2098.5009.41 2098.0307.01 A23 GS ZR800V1 VORST.SA SX800 ZR800V1 EXC.INST. KIT VAR 24 Vorstufensatz - DTV ohne ADE 2099.1507.04 2098.0307.01 A200 GG NETCCU 800 CONTROL UNIT NETCCU 800 CONTROL UNIT VAR 04 24 2095.8007.02 2098.0307.01 A100A GG SX800 TV EXCITER DTV UND ADE INT RF SX800 TV EXCITER VAR 04 24 2095.1502.71 2098.0307.01 A100B GG SX800 TV EXCITER DTV UND ADE INT RF SX800 TV EXCITER VAR 24 2095.1502.71 2098.0307.01 Benennung/Designation NV8301X DTV-SENDER NV8301X DTV XMTR NV8301X Datum/ Date 2008-01-17 Abt. / Dept. Sprach./Lang Ä.I. / C.I de en 01.00 Blatt/Sheet 1 of 1 Dokument Nr. / Document No. 7TSK Name / Name Ro 2098.0307.01 SA ROHDE & SCHWARZ A100A #) A100B 2000 A200 A1 Tiefe: 800 Depth: 800 600 Variantenerklärung siehe Schaltteilliste #) OPTION 01.00 Valid for model see parts list 01.08 RO 7TSK Tag Bearb. 01.08 Name RO Gepr. Norm S\DESI-DAT\NV8300\NV8301x ÄnderungsMitteilung NV8301x DTV-Sender Bd.IV/V DTV-TANSMITTER BD.IV/V Name zu Gerät Blatt-Nr. 2098.0307.01 ROHDE & SCHWARZ Tag Zeichn.-Nr. Änd. Zust. Benennung NV8301x reg. i. V. 2098.0307 V erste Z. 0000.0000.00 v. Bl. Broadcasting Division Drawings and Diagrams NV8302E/V 2098.0059.01 Printed in Germany 2098.0188.72 -2- E-1 E X121A TS2 input 260mVpp...2Vpp 75 TS3 input 260mVpp...2Vpp 75 W21A X20 X122A W22A X21 X123A W23A X25 X124A TS 1/2 monitoring 800mVpp -+30% 75 X131A TS 3/4 monitoring 800mVpp -+30% 75 X132A 1PPS EXTERNAL input 50 X141A 1PPS monitoring 75 X142A 10 MHz REF input -5...20dBm 50 X143A W24A X26 11 12 13 14 15 16 RF OUTPUT 2-FACH-SPLITTER A41 BV832H1 2096.4405.xx 2 TO 1 COUPLER A40 A100A SX800 TV EXCITER 2095.1502.xx 1 TO 2 SPLITTER X60 2096.4305.xx W32A W1 X1 Messausgang measuring output X11 BLATT 5: STROMLAUF STEUERKABEL sheet 5: circuit diagram signal cable +)AUSKOPPELDAEMPFUNG P14 SIEHE SYSTEM-HANDBUCH BLATT 6: STROMLAUF NETZKABEL sheet 6: circuit diagram power cable X27 W41A X24 W42A X67 1.RF DEMOD IN X68 W43A E) A1 VH8300A1 UHF-VERSTAERKER V) W300A1 X.A1 X1 E) HF-SCHALTER IN POS:2 X64 V)R15A X4 RF SWITCH IN POSITION 2 W300 X2 W307A TS2 input 260mVpp...2Vpp 75 X122B TS3 input 260mVpp...2Vpp 75 X123B TS4 input 260mVpp...2Vpp 75 X124B TS 1/2 monitoring 800mVpp -+30% 75 X131B V) W31B X22 TS 3/4 monitoring 800mVpp -+30% 75 X132B V) W32B X27 1PPS EXTERNAL input 50 X141B V) W21B X20 V) W22B X21 V) W23B X25 V) W24B X26 V) W41B X3 X.E A2 VH8300A1 UHF-VERSTAERKER X.A2 W307B X10 A45 X.E1 UHF AMPLIFIER X.A X3 X.E2 X2 2096.6508.01 OBERWELLENFILTER HARMONICS FILTER X24 2.RF DEMOD IN V) W43B P14C XMTR RF OUTPUT ak=+)dB E) W2ADE E) X67 E) W3ADE E) V) X68 E) W4ADE E) V) RF OUTPUT O) OPTION ODER INSTALLATION VOM KUNDEN OR INSTALLED BY CUSTOMER V) W300B1 W1ADE HF-AUSGANG MESSRICHTKOPPLER E) OPTION ADE AUTOMAT. ENTZERRUNG ADE SYSTEM KIT SX800Z1 2099.4006.01 V) OPTION VORSTUFEN SATZ SX800 ZR800V1 2099.1507.01 EXCITER STANDBY INSTALL KIT E) V) HIERZU SIEHE AUCH: 2098.5009.01 SA (ZR800C1) see also: 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) E) V) HF-BLOCKSCHALTBILD GUELTIG FUER VAR: SIEHE SCHALTTEILLISTE VALIED FOR MODELS: SEE PARTS LIST BLOCK DIAGRAM OF RF SIGNAL Benennung / Designat.: ROHDE&SCHWARZ NV8302X NV8302X E) P14 GD800 X64 FILTER 2096.7204.xx X23 V) W42B P14D ak=+)dB O) BLITZSCHUTZ DIRECTIONAL COUPLER X60 1.RF DEMOD IN ak= dB E) V)W300B1 HF-SENDER AUFGANG P14B P14A ak= dB X3 V) A100B SX800 TV EXCITER 2095.1502.xx RF OUTPUT UHF AMPLIFIER O) MESSRICHTKOPPLER DIRECTIONAL COUPLER X2 V)W304 V)A15 HF-SCHALTER X10 P24 DACH TOP X23 X121B 10 MHz REF input -5...20dBm 50 2096.3909.xx COUPLING ATTENUATION P14 SEE ALSO SYSTEM MANUAL 2095.3257.xx X143B TERMINATION X1 BLATT 4: BLOCKSCHALTBILD STEUERLEITUNG sheet 4: block diagram of signal ABSORBERBLOCK 2-FACH-KOPPLER W300 RF SWITCH 1PPS monitoring 75 A42 V) W300A1 2.RF DEMOD IN X142B 17 BLATT 3: NETZ-STROMLAUF MIT USV sheet 3: circuit diagram with UPS X22 W31A TS1 input 260mVpp...2Vpp 75 10 BLATT 2: NETZ-STROMLAUF sheet 2: circuit diagram V) EXCITER B BLATT 1: HF-BLOCKSCHALTBILD sheet 1: block diagram of rf signal 50 OHM 50 OHM ak= 60 dB 50 OHM Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved DACH TOP TS1 input 260mVpp...2Vpp 75 TS4 input 260mVpp...2Vpp 75 ak= 60 dB EXCITER A OPTION 10 11 12 13 NV8302X 14 Datum: Date: 08/07/18 DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 1+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0059.01 S 16 17 Q1 W3 W2 W1 L1 L2 L3 W.PE X20.1-3 W4 17 +12V A31 NETZVERTEILUNG MITTELLEISTUNG Main distribution MP K1 1 K2 1 K3 1 NC NC GND GND 21 22 23 24 18 25 14 15 16 17 12 GND GND GND GND X45.2 11 GND GND +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS CL_DL_ON_OFF COOLING_ON_OFF X45.1 F1 +12V 10 13 19 20 LOOP+_RESERVE LOOP-_COM LOOP+_MAIN FAULT2_ABS FAULT1_ABS 0V PRES 2 PRES 1 + 5V FAULT2_CL FAULT1_CL X44. WARNING_CL X10 OVERCUR_EXT_CL NICHT BELEGT NC X43. + 12V GND + 5V X42. GND X43B PRES 2 LINK + 5V LINK 16 GESTELLSTEUERUNG / Rack controller OPTION LUFTMAENGEN-MESSUNG air quantity measurement GND LINK 15 +12V X.PE1 LINK 14 +12V LINK 13 +12V T1 T2 T3 12 PRES 1 EXTERNAL POWER KIT X41. L N PE 11 RF LOOP SCHUTZSCHLEIFE Z1) OPTION ZR800Z1 2099.3000.xx BAUSATZ STECKDOSE EXTERN #) Z1) X57 10 UEBERSTROM EXT KUEHLUNG overcurrent ext.cooling PE NICHT BELEGT not connected L1 L2 L3 N STOERUNG KUEHLUNG 1 fault cooling 1 230/400V AC NETZSTECKDOSE AC supply connector 230V AC max. 10A min.3x1qmm STOERUNG KUEHLUNG 2 fault cooling 2 BETRIEBSERDE system ground STOERUNG GESTELL ABS fault rack abs 2098.0094.xx STOERUNG ANLAGEN ABS fault system abs VORSICHERUNG UND ANSCHLUSSQUERSCHNITT SIEHE SYSTEM-HANDBUCH NV8302E/V External fuseing and cable cross-sections see system manual NV8302E/V RESERVESENDER standby xmitter BETRIEBSSENDER main xmitter 2096.3009.xx L1 L2 L3 X1. X2. L1 W.L1 L2 W.L2 L3 W.L3 Q3X Q2 Q3 I>> I>> I>> I>> I>> I>> X20.1 F8 3A 2 F5 3A 2 F1 3A 2 F2 3A 2 F3 3A 2 F4 3A 2 X6 X7 X8 X5 X1 X2 X3 X4 X61 X62. U1 V1 W1 U1 V1 W1 A2 VH8300A1 UHF AMPLIFIER UHF AMPLIFIER UHF-VERSTAERKER UHF-VERSTAERKER C1A 8u 3 4 5 6 7 A1 VH8300A1 X1. XE1.1 2 K1 L2 X31. W31 W62 X1. X20.1 W61 F7 3A 2 E1 LUEFTER FAN 2096.2131.xx L3 X32. W32 XE2.1 2 K1 C2A 8u L3 X33. K2 L3 #) E2 LUEFTER FAN 2096.2131.xx L3 X36. #) 3 4 5 6 7 K3 #) OPTION STEUERBEFEHL FUER EXTERNE KUEHLUNG EIN control command for OPTION external cooling on STEUERBEFEHL FUER KUNSTANTENNE EIN control command for dummy load on OPTION NETZANSCHLUSS FUER EXTERNEN ABS - LUEFTER AC supply for external ABS cooling L1 X35. 1 2 W35 X45. 1 2 L1 L1 L1 X34.1 W60 X52.52 53 54 55 71 81 Vout + Vout + W62C GND Vout Vout - NETZTEIL POWER SUPPLY 1081.0254.00 63 73 83 A200 NETCCU 800 10 11 A100A EXCITER A 12 PE A35 VERTEILER-N-NETZ Interface Power N Distribution X.PE Z2) OPTION ZR800Z2 2099.3100.xx BAUSATZ STECKDOSE INTERN V) OPTION ZR800V1 2099.1507.xx VORSTUFEN SATZ SX800 EXCITER B EXCITER STANDBY INSTALL KIT PE L N PE L N PE Z2) X55Z NV8302X 14 Datum: Date: 08/07/18 NETZ-STROMLAUF GUELTIG FUER VAR: SIEHE SCHALTTEILLISTE VALIED FOR MODELS: SEE PARTS LIST Benennung / Designat.: ROHDE&SCHWARZ NV8302X NV8302X 13 W155Z NETZANSCHLUSS FUER ZUSATZGERAETE AC supply for additional units A100B HIERZU SIEHE AUCH: 2098.5009.01 SA (ZR800C1) see also: 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) INTERN POWER POINT KIT 65 75 85 V) W62B W62A 64 74 84 #) INSTALLATION VOM KUNDEN #) installed by customer X.N3 X.N2 L1 +12V A 36 X.N1 2096.3550.xx X52.62 72 82 W4 W45 ACL ACN X20.1 F6 3A 2 GND +12V X10.25 Q2X X10.18 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved W3PH DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK CIRCUIT DIAGRAM Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 2+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0059.01 S 16 17 Q1 W3 W2 W1 L1 L2 L3 W.PE 13 X20.1-3 W4 W1PH 23 W.N3 Z5) F1 L N PE 11 +12V K1 1 K2 1 K3 1 NC NC 21 22 23 24 18 25 14 15 16 17 12 GND GND GND GND +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS CL_DL_ON_OFF LOOP+_RESERVE COOLING_ON_OFF LOOP-_COM 10 LOOP+_MAIN 13 19 20 FAULT2_ABS FAULT1_ABS FAULT2_CL FAULT1_CL WARNING_CL 0V PRES 2 PRES 1 + 5V OVERCUR_EXT_CL NICHT BELEGT NC X44. + 12V GND + 5V X43. GND PRES 2 + 5V X42. X10 GND GND GND GND X45.2 A31 NETZVERTEILUNG MITTELLEISTUNG Main distribution MP X43B X45.1 X.PE2 LINK 17 GESTELLSTEUERUNG / Rack controller OPTION LUFTMAENGEN-MESSUNG air quantity measurement +12V 24 LINK 16 +12V X.PE1 LINK 15 +12V LINK X41. #) Z1) X57 LINK 14 +12V T1 T2 T3 Z5) Q1.1 14 EXTERNAL POWER KIT 13 GND #) 12 PRES 1 #) 11 UEBERSTROM EXT KUEHLUNG overcurrent ext.cooling PE 10 NICHT BELEGT not connected L1 L2 L3 N RF LOOP SCHUTZSCHLEIFE Z1) OPTION ZR800Z1 2099.3000.xx BAUSATZ STECKDOSE EXTERN NETZSTECKDOSE AC supply connector 230V AC max. 10A min.3x1qmm UPGRADE KIT EXTERNAL UPS STOERUNG KUEHLUNG 1 fault cooling 1 230/400V AC STOERUNG KUEHLUNG 2 fault cooling 2 BETRIEBSERDE system ground Z5) OPTION ZR800Z5 2099.3400.xx BAUSATZ EXTERNE USV STOERUNG GESTELL ABS fault rack abs 2098.0094.xx ACHTUNG !/ CAUTION ! NETZVERSORGUNG VON EXTERNER USV POWER SUPPLY FROM EXTERNAL UPS 230 AC max. 5A N PE STOERUNG ANLAGEN ABS fault system abs VORSICHERUNG UND ANSCHLUSSQUERSCHNITT SIEHE SYSTEM-HANDBUCH NV8302E/V External fuseing and cable cross-sections see system manual NV8302E/V RESERVESENDER standby xmitter BETRIEBSSENDER main xmitter 2096.3009.xx L1 L2 L3 X2. X1. L2 W.L2 L3 W.L3 Q3X Q2X Q3 I>> I>> I>> F7 3A 2 F8 3A 2 F5 3A 2 F1 3A 2 F2 3A 2 F3 3A 2 F4 3A 2 X6 X7 X8 X5 X1 X2 X3 X4 X61 X1. X62. C1A 8u X1. U1 V1 W1 XE1.1 2 U1 V1 W1 3 4 5 6 7 A1 VH8300A1 UHF-VERSTAERKER UHF AMPLIFIER A2 VH8300A1 UHF-VERSTAERKER E1 UHF AMPLIFIER LUEFTER FAN 2096.2131.xx K1 L2 X31. W31 W62 K1 X20.1 W61 F6 3A 2 L3 X32. W32 C2A 8u XE2.1 2 L3 X33. K2 #) E2 LUEFTER FAN 2096.2131.xx L3 L3 X36. #) 3 4 5 6 7 K3 #) OPTION STEUERBEFEHL FUER EXTERNE KUEHLUNG EIN control command for OPTION external cooling on STEUERBEFEHL FUER KUNSTANTENNE EIN control command for dummy load on OPTION NETZANSCHLUSS FUER EXTERNEN ABS - LUEFTER AC supply for external ABS cooling L N3 X35. 1 2 W35 W45 ACL ACN W62C GND Vout Vout - A 36 W60 X52.52 Vout + Vout + POWER SUPPLY 1081.0254.00 X34.1 +12V NETZTEIL 10 X.N3 A35 VERTEILER-N-NETZ Interface Power N Distribution X.PE N3 54 63 73 83 A200 NETCCU 800 11 A100A EXCITER A 12 Z2) OPTION ZR800Z2 2099.3100.xx BAUSATZ STECKDOSE INTERN V) V) OPTION ZR800V1 2099.1507.xx VORSTUFEN SATZ SX800 EXCITER B 13 EXCITER STANDBY INSTALL KIT W155Z NETZANSCHLUSS FUER ZUSATZGERAETE AC supply for additional units A100B HIERZU SIEHE AUCH: 2098.5009.01 SA (ZR800C1) see also: 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) INTERN POWER POINT KIT 65 75 85 64 74 84 PE 55 71 81 V) W62B W62A 53 L N3 #) INSTALLATION VOM KUNDEN #) installed by customer X.N2 X20.1 2096.3550.xx X52.62 72 82 X.N1 X45. 1 2 W4 I>> I>> I>> X20.1 Z5) W.N3 GND Q2 +12V X10.25 X10.18 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved W3PH PE L N PE L N PE Z2) X55Z DARSTELLUNG MIT NETZVERSORGUNG VON EXTERNER USV DESCRIPTION FOR POWER SUPPLY FROM EXTERNAL UPS ROHDE&SCHWARZ NV8302X NV8302X 14 Datum: Date: CIRCUIT DIAGRAM VALIED FOR MODELS: SEE PARTS LIST Benennung / Designat.: NV8302X NETZ-STROMLAUF GUELTIG FUER VAR: SIEHE SCHALTTEILLISTE 08/07/18 DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 3+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0059.01 S 16 17 1 10 11 12 X9 .1 X2 .1 .9 .9 .1 W59 X10 .9 .8 .1 X53A .1 CAN BUS ABSCHLUSSWIDERST. W56A X3 .8 .1 TERMINATING RESISTOR 2097.5628.00 ETHERNET A .8 *) RS232 W47 .9 ETHERNET X7 X5 W48 .1 .1 .1 .8 A200 .1 TX CONTROL .9 W55 .1 W55 ETHERNET B X12 .25 .1 X11 .15 X12 BLINDSTECKER X4 .1 V) W70 V) W56B X6 X10 .1 .9 .1 .1 X2 .8 2095.3257xx .15 EXCITER RF SWITCH PARALLEL REMOTE INTERFACE 3562.4210.xx A50 .1 EXTERNE PUMPE 2099.1507.01 TERMINATING RESISTOR 2097.5605.00 W53D .15 CAN 3 NICHT BELEGT NOT CONNECTED HF-MESSSTELLEN RF PROBES NICHT BELEGT NOT CONNECTED X9 .1 .9 X6 W52 2096.3550.xx 2095.1502.xx X43 .1 .2 W51B S.E2 DRUCKDOSE PRESSURE BOX 2077.3936.xx .3 .4 X41. 1 2 3 4 X42. 1 2 3 4 W45 Bruecke / Link .1 W51B .3 Bruecke / Link ABSORBER SCHUTZSCHLEIFE RF LOOP UEBERSTROM EXTERNE KUEHLUNG OVER CURRENT EXTERNAL COOLING PRESSURE BOX 2077.3936.xx .1 W51A .3 HIERZU SIEHE AUCH: see also: 2098.5009.01 SA (ZR800C1) 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) .1 X.Vout .4 Bruecke / Link A36 NETZTEIL POWER SUPPLY 1081.0254.00 see sheet 2,3 S.E1 DRUCKDOSE .1 X45 .4 X44. 1 2 W51A siehe Blatt 2,3 X10 .25 .1 .9 TV EXCITER X8 .25 .1 INTERFACE POWER N DISTRIBUTION ONLY BY SINGLE EXCITER X53D CAN BUS ABSCHLUSSWIDERST. EXTERNAL PUMP TV STEUERSENDER 2095.3305.xx .15 .1 2095.6004.01 VERTEILER-N-NETZ E) NUR BEI EINZEL-VORSTUFE W53D UHF AMPLIFIER A35 EXCITER RF SWITCH FOR ADE EXCITER STANDBY INSTALL KIT A2 VH8300A1 UHF-VERSTAERKER 2096.4505.xx V) A100B SX800 VORST.SCHALTER FUER ADE V) ZR800V1 VORSTUFEN SATZ SX800 .1 .1 .1 X4 .15 TON VERSTAERKER .9 GESTELLSTEUERUNG .1 .1 X5 F) ZR800F1 PARALLELE-FERNSCHNITT-STELLE X11 CAN 2 ETHERNET V) A15 VORST.SCHALTER 2095.6004.01 .15 2097.5611.00 SOUND AMPLIFIER CAN 1 .15 TERMINATING RESISTOR W50 .9 X53B CAN BUS ABSCHLUSSWIDERST. V) W54B 2097.5657.00 *) OPTION .20 W58AB .1 X7 .9 .1 E) X54B .9 .1 X7 .9 .8 DUMMY PLUG 2094.0260.xx UHF AMPLIFIER RACK CONTROLLER 2095.8007.xx .1 ASI DISTRIBUTOR .9 .9 .9 2010.0006.xx W50 W53D .1 .9 VITIATED AIR SENSOR .9 .1 X11B .9 W50 .1 A60B ASI VERTEILER W58B W54A .9 W55 X6 .1 NETCCU 800 X6 X100A ETHERNET REMOTE X232 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved .1 B2 ABLUFT SENSOR ETHERNET A1 VH8300A1 UHF-VERSTAERKER .20 X3 2096.6308.xx .9 DACH TOP 2094.0260.xx X2 RF REFLECTED ANT. W59 X2 W57 2095.1502.xx X2 GD800Z2 .1 P14B HF-RUECKLAUF ANT. X5 3562.3707.xx ASI DISTRIBUTOR .9 W50 X11 TV STEUERSENDER X53A REMOTE INTERFACE 2010.0006.xx W58A TV EXCITER X1 F) ZR800F1 .1 A57 FERNSCHNITTSTELLE INCOMING AIR SENSOR .1 A60A ASI VERTEILER X53D .9 X11 .9 .1 A100A SX800 .1 X2 2096.6308.xx TERMINATING RESISTOR W59 B1 ZULUFT SENSOR X2 2097.5628.00 RF FORWARD ANTENNA .1 X1 GD800Z2 P14A HF-VORLAUF ANT. X1 X53A CAN BUS ABSCHLUSSWIDERST. X11 .1 W53D ROHDE&SCHWARZ NV8302X NV8302X NV8302X Datum: Date: 08/07/18 BLOCKSCHALTBILD STEUERLEITUNG BLOCK DIAGRAM OF SIGNAL Benennung / Designat.: DTV-SENDER DTV XMTR Abteilung: Dept.: 10 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 4+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 11 2098.0059.01 S 12 1 X12 X53A 2097.5657.00 NETCCU 800 CAN_L 2 X12. SWI1_OS_POS_II 15 GND 16 BRUECKE SWI1_OS_PL 24 GND 25 BRUECKE X41 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved RF LOOP BETRIEBSSENDER MAIN XMITTER BRUECKE LINK NC R35B TX TX RX RX NC CAN_L 6 VERTEILER-N-NETZ X42. ABSORBER STOERUNG FAULT ABSORBER FAULT2_ABS 1 GND_0V 2 ANLAGE SYSTEM CAN_H 14 15 gn ge +12V +12V GND GND 4055.6458.00 ETHERNET REMOTE ASI VERTEILER A ASI DISTRIBUTOR A X11B. #) #) #) #) #)Bruecke auf GS X100A. X5. RACK CONTROLL UNIT 1 TX + 2 TX 3 RX + 6 RX - #) Link on PCB A60A X2. RACK NC X54B W53D 2097.5592.00 REDUCED_REF_B INTERFACE POWER DISTRIB. A35 X44. OVERCURRENT 1 _EXT_CL GND_0V 2 BRUECKE LINK UEBERSTROM EXT. KUEHLUNG GND A35 X10. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 W51AB 2097.5463.00 10 11 12 13 14 15 VERTEILER-NETZ BRUECKE INTERF: POWER DISTRIB. LINK A50 X3. A35 X43. W51B FAULT2_CL 1 GND_0V 2 WARNING_CL 6 GND_0V 7 W51A DRUCKDOSE PRESSURE BOX S.E2 S.E1 N.C. N.C. OVERCU_EXT_CL WARNING_CL FAULT1_CL FAULT2_CL FAULT1_ABS FAULT2_ABS LOOP+_MAIN LOOP_COM LOOP+_RESERVE GND_0V COOLING_ON_OFF CL_DL_ON_OFF +5V +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS SENSE+ PRES1 PERES2 GND GND GND GND SENSE- 13 W55 RACK CONTROLL UNIT 10 11 12 13 14 15 10 11 12 13 14 15 10 11 12 13 14 15 10 11 12 13 14 15 X6. X6. W54B +12V_RC N.C. GND LOOP-_EXC_A REDUCED_REF_A GND N.C. LOOP+_EXC_A +12V_RC A200 X7. 2097.5405.00 GESTELLSTEUERUNG SX800B EXCITER B RACK CONTROLL UNIT A100B A50 X7. X6. +12V_RC N.C. GND LOOP-_EXC_B REDUCED_REF_B GND N.C. LOOP+_EXC_B +12V_RC TX TX RX RX W56B A100B X2. RX RX TX TX 2097.5428.00 A50 X10. W58B W59 /SWI_EXC_POS1_A GND /SWI_EXC_SELECT2_B /SWI_EXC_POS2_B /SWI_EXC_SELECT3_B /SWI_EXC_POS3_B GND /SWI_EXC_SELECT1_B /SWI_EXC_POS1_B /SWI_EXC_SELECT2_A /SWI_EXC_POS2_A /SWI_EXC_SELECT3_A /SWI_EXC_POS3_A +12V_SWI_EXC NETCCU 800 A200 X10. B1.ZU B2.AB 2097.5457.00 HF-VORLAUF ANT. RF FORWARD ANTENNA P14A X1. HF-RUECKLAUF ANT. RF REFLECTED ANTENNA GND PEAK/AV1 +12V N.C. N.C. RF_PROBE1 ADJUST1 N.C. N.C. P14B X1. N.C. N.C. +12V PEAK/AV2 GND N.C. N.C. ADJUST2 RF_PROBE2 STROMLAUF DER STEUER-KABEL CIRCUIT DIAGRAM FROM THE SIGNAL CABLE ROHDE&SCHWARZ NV8302X NV8302X 13 10 11 12 13 14 15 Benennung / Designat.: 12 A15 X5. TEMPERATURE MONITOR *) OPTION 11 EXCITER RF SWITCH TEMPERATURFUEHLER W58A TV EXITER B A200 X4. TX TX RX RX N.C. CAN-L CAN_GND N.C. N.C. GND CAN-H N.C. CAN_V+ VORSTUFEN-SCHALTER RACK CONTROLL UNIT SX800 B ETHERNET B 17 2097.5370.00 10 11 12 13 14 15 X9. GESTELLSTEUERUNG 1139.2247.00 NETCCU 800 TX TX RX RX GND DGND AGND /AMPL_ERR RESET AMPL_ON VREF_PWR PEAK_AV PWR_OUT CAN_GND CAN_L CAN_H CAN_V+ /AC_OK NC SX800 A A200 X11. A200 W58AB A100A X2. NETCCU 800 TV EXITER A A200 X3. NETCCU 800 X1. +12V_RED CAN1_L CAN_GND +12V_RED CAN_SHLD GND CAN1_H +12V_ASI CAN_V+ 0041.9283.00 ETHERNET A W70 A57 A50 X2. NETCCU 800 X53D. 10 X53A. 16 *) 3562.3765.00 REMOTE INTERFACE GESTELLSTEUERUNG CAN BUS ABSCHL. RACK CONTROLL UNIT CAN BUS TERMINATING W56A CAN-Bus 10 11 12 13 14 15 W57 2097.5411.00 NETCCU 800 A50 A100A 15 FERNSCHNITTSTELLE UHF AMPLIFIER 10 11 12 13 14 15 14 GESTELLSTEUERUNG SX800A UHF-VERSTAERKER A3 A2 A5 A6 A1 A4 X11. X11. X11. X11. X11. X11. 10 11 12 13 14 15 12 2097.5392.00 EXCITER A 2097.5357.00 RACK CONTROLL UNIT OVERCURRENT EXT. COOLING INTERFACE POWER DISTRIBUTION GESTELLSTEUERUNG FAULT1_CL 3 20 120 OHM A50 X7. VERTEILER-N-NETZ +12V +12V R35D RACK CONTROLL UNIT 2097.5634.44 ASI 3 ASI 4 TERMINATING RESISTOR GESTELLSTEUERUNG X44 W54A VERTEILER-NETZ 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 20 LINK GESTELL A50 X8. A60B X2. 1 ASI 1 2 ASI 2 5 +12V 6 +12V 7 ASI 3 8 ASI 4 10 11 +12V 12 +12V 13 BRUECKE FAULT1_ABS 3 GND_0V 4 RACK CONTROLL UNIT ASI VERTEILER B ASI DISTRIBUTOR B 11 2097.5363.00 GESTELLSTEUERUNG CAN-BUS ABSCHLUSS-WIDERSTAND NC 10 W52 *) 2097.5386.00 GESTELLSTEUERUNG A50 X11. 2097.5605.00 X53D. 2097.5634.42 A36 X.P2 bn A200 TERMINATING RESISTOR X53D ETHERNET 120 OHM CAN_H 14 15 POWER SUPPLY NETCCU 800 STANDBY XMITTER INTERFACE POWER DISTRIB. CAN_L 6 CAN-BUS ABSCHLUSS-WIDERSTAND W50 NETZTEIL ws W48 2097.5611.00 RESERVESENDER A35 N.C. N.C. +12V GND NC X53B. SCHUTZSCHLEIFE X41. X42 A35 X45. 120 OHM 2096.3444.00 INTERFACE POWER N DISTRIB. TERMINATING RESISTOR X53B VERTEILER-N-NETZ LINK VERTEILER-N-NETZ LOOP-_RESER.3 LOOP_COM NC W45 R35A CAN_H 7 2097.5634.41 LOOP+_MAIN 1 LOOP_COM CAN-BUS ABSCHLUSS-WIDERSTAND LINK INTERFACE POWER DISTRIB. A35 2097.5628.00 X53A. TX CONTROL A200 NV8302X 14 Datum: Date: 08/07/18 DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 5+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0059.01 S 16 17 1 X33 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved INTERFACE POWER DISTRIB. A35 X31. L2 1 N 2 PE 3 230V AC X36. A35 X32. L3 1 N 2 PE 3 *) LINK AT PLUG INTERFACE POWER DISTRIB. A35 X34. X.E1 2 L2 4 N 7 PE C1A 8 L1 L1 L1 L1 PE E2 FAN CONNECTION bl/2 gnge 2 L3 4 N 7 PE C2A 8 NETZVERTEILUNG POWER DISTRIBUTION A31 Q2-Q7. X20.1-3 E1 FAN CONNECTION bl L2 2 N 4 PE 7 E2 W35 FAN *) o) E1 2096.3450.00 VERTEILER-NETZ A35 X35. sw *) bn L1 1 N 2 PE 3 gnge A200 NETCCU bn/1 bl/2 gnge W155Z 1 L1 2 N.C. 3 N PE A100B W62B SX800 B 2096.2131.01 E2 LUEFTERANSCHLUSS SX800 B TV EXCITER B AC VERTEILUNG ZUSATZGERAETE A100B X1. AC POWER DISTRIBUTION ADDITIONAL UNITS X52. bn/1 64 74 84 L1 PE bl/2 gnge 2097.5086.00 AC VERSORGUNG VERSTAERKER AC POWER SUPPLY AMPLIFIER A1-A6 X1. sw/1 W62C 1 L1 3 L2 4 L3 PE bl/2 bn/3 gnge 2097.4921.00 NETCCU 800 AC VERTEILUNG A200 X1. AC POWER DISTRIBUTION X52. bn/1 62 72 82 L1 PE bl/2 gnge 2097.5028.00 NETZANSCHLUSS FUER ZUSATZGERAETE AC VERTEILUNG 65 75 85 2097.4944.00 BIS / TO AC POWER DISTRIBUTION X52. gnge SX800 A POWER SUPPLY A36 X.P1 L1 PE bl/2 A100A NETZTEIL INTERFACE POWER DISTRIB. A100A X1. bn/1 63 73 83 2097.5034.00 W61-W66 E1 LUEFTERANSCHLUSS LUEFTER X52. X.E2 bn/1 SX800 A TV EXCITER A AC POWER DISTRIBUTION AC VERTEILUNG 2097.4938.00 AC VERTEILUNG AC POWER DISTRIBUTION 62 72 82 63 73 83 64 74 84 65 75 85 E2 LUEFTERANSCHLUSS 2096.2131.01 X.E1 52 53 54 55 71 81 X52. W62A 2097.4950.00 2096.3438.00 INTERFACE POWER DISTRIB. *) BRUECKE AM STECKER E1 gnge VERTEILER-NETZ E1 FAN CONNECTION bl/2 VERTEILER-NETZ NETZANSCHLUSS L3 1 EXT.ABS LUEFTER N 2 AC SUPPLY FOR PE 3 EXT. ABS COOLING W60 E1 LUEFTERANSCHLUSS bn/1 W32 2097.5634.36 2096.3421.00 VERTEILER-NETZ 230V AC STEUERBEFEHL L3 1 KUNSTANTENNE EIN N 2 CONTROL COMMAND PE 3 DUMMY LOAD ON X36 W31 2097.5634.33 X33. L3 1 STEUERBEFEHL EXT.KUEHLUNG EIN N 2 CONTROL COMMAND PE 3 EXT.COOLING ON AC SUPPLY FOR ADDITIONAL UNITS bn/1 L1 PE bl/2 gnge E2 FAN CONNECTION X.E2 L2 2 N 4 PE 7 LUEFTER bl FAN *) o) E2 STROMLAUF DER NETZ-KABEL sw CIRCUIT DIAGRAM FROM THE POWER CABLE *) bn Spr.:/Lang.: Aei:/C.I.: Benennung / Designat.: ROHDE&SCHWARZ NV8302X NV8302X gnge NV8302X Datum: Date: 08/07/18 DTV-SENDER DTV XMTR Abteilung: Dept.: 7TSK de 02.00 Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a Blatt:/Sh.: 6- 2098.0059.01 S el.Kennz Part Benennung / Hinweise Designation Sachnummer Stock No. Hersteller Manufacturer Bestellbezeichnung Designation enthalten in contained in ACHTUNG EGB /ATTENTION ESD Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision *VARIANTENERKLAERUNG *EXPLANATION OF MODELS VAR04=NV8302E DTV-SENDER MIT EINZEL-VORSTUFE PROGNOSESENDER MOD04=NV8302E DTVTRANSMITTER WITH SINGLE EXCITER VAR24=NV8302V DTV-SENDER MIT VORSTUFE-RESERVE OHNE ADE PROGNOSESENDER MOD24=NV8302V DTV TRANSMITTER WITH DUAL DRIVE WITHOUT ADE VAR50=NV8302X DTV-SENDER +++GRUNDSENDER+++ MOD50=NV8302X DTVTRANSMITTER ++BASIC TRANSMITTER++ A1 - A2 GG VH8300A1 UHF-VERSTAER. 3Phasig VH8300A1 UHF-AMPLIFIER VAR 04 24 2095.6004.02 2098.0059.01 A20 GS ZR800T1 EINBAUS. SX800 ZR800T1 INSTAL. KIT VAR 04 24 DTV - Ausfuehrung 2099.1007.03 2098.0059.01 A21 GS ZR800C1 LEISTUNGSSATZ ZR800C1 POWER KIT VAR 04 24 Leistungssatz fuer 2 Verstaerker 2098.5009.42 2098.0059.01 A23 GS ZR800V1 VORST.SA SX800 ZR800V1 EXC.INST. KIT VAR 24 Vorstufensatz - DTV ohne ADE 2099.1507.04 2098.0059.01 A200 GG NETCCU 800 CONTROL UNIT NETCCU 800 CONTROL UNIT VAR 04 24 2095.8007.02 2098.0059.01 A100A GG SX800 TV EXCITER DTV UND ADE INT RF SX800 TV EXCITER VAR 04 24 2095.1502.71 2098.0059.01 A100B GG SX800 TV EXCITER DTV UND ADE INT RF SX800 TV EXCITER VAR 24 2095.1502.71 2098.0059.01 Benennung/Designation NV8302X DTV-SENDER NV8302X DTV XMTR NV8302X Datum/ Date 2008-01-17 Abt. / Dept. Sprach./Lang Ä.I. / C.I de en 01.00 Blatt/Sheet 1 of 1 Dokument Nr. / Document No. 7TSK Name / Name Ro 2098.0059.01 SA ROHDE & SCHWARZ A100A #) A100B 2000 A200 A1 A2 Tiefe: 800 Depth: 800 600 Variantenerklärung siehe Schaltteilliste #) OPTION 01.00 Valid for model see parts list 01.08 RO 7TSK Tag Bearb. 01.08 Name RO Gepr. Norm S\DESI-DAT\NV8300\NV8302x ÄnderungsMitteilung NV8302x DTV-Sender Bd.IV/V DTV-TANSMITTER BD.IV/V Name zu Gerät Blatt-Nr. 2098.0059.01 ROHDE & SCHWARZ Tag Zeichn.-Nr. Änd. Zust. Benennung NV8302x reg. i. V. 2098.0059 V erste Z. 0000.0000.00 v. Bl. Broadcasting Division Drawings and Diagrams NV8303E/V 2098.0107.01 Printed in Germany 2098.0188.72 -3- E-1 E X121A TS2 input 260mVpp...2Vpp 75 TS3 input 260mVpp...2Vpp 75 W21A X20 X122A W22A X21 X123A W23A X25 X124A TS 1/2 monitoring 800mVpp -+30% 75 X131A TS 3/4 monitoring 800mVpp -+30% 75 X132A 1PPS EXTERNAL input 50 X141A 1PPS monitoring 75 X142A 10 MHz REF input -5...20dBm 50 X143A W24A X26 11 12 13 14 15 16 RF OUTPUT 3-FACH-SPLITTER A41 BV833H1 2096.4234.xx 3 TO 1 COUPLER A40 A100A SX800 TV EXCITER 2095.1502.xx 1 TO 3 SPLITTER X60 2096.4157.xx W300 W32A W41A A1 VH8300A1 UHF-VERSTAERKER X23 X24 W42A X67 1.RF DEMOD IN X68 W43A X.A1 E) V) W300A1 E) X1 V)R15A X4 W307A X10 RF SWITCH IN POSITION 2 W300 X2 X.E X.A2 W307B X10 TERMINATION X1 W1 X1 Messausgang measuring output X11 X2 W2 X2 X12 2096.3909.xx BLATT 5: STROMLAUF STEUERKABEL sheet 5: circuit diagram signal cable +)AUSKOPPELDAEMPFUNG P14 SIEHE SYSTEM-HANDBUCH BLATT 6: STROMLAUF NETZKABEL sheet 6: circuit diagram power cable COUPLING ATTENUATION P14 SEE ALSO SYSTEM MANUAL TS2 input 260mVpp...2Vpp 75 X122B TS3 input 260mVpp...2Vpp 75 X123B TS4 input 260mVpp...2Vpp 75 X124B TS 1/2 monitoring 800mVpp -+30% 75 X131B V) W31B X22 TS 3/4 monitoring 800mVpp -+30% 75 X132B V) W32B X27 1PPS EXTERNAL input 50 X141B V) W21B X20 V) W22B X21 V) W23B X25 V) W24B X26 V) W41B X.A3 W307C X10 UHF AMPLIFIER X.A 2096.6508.01 OBERWELLENFILTER X3 HARMONICS FILTER X.E3 V) W42B X24 2.RF DEMOD IN V) W43B ak= dB P14D P14C FILTER DIRECTIONAL COUPLER W2ADE E) X67 E) W3ADE E) V) X68 E) W4ADE E) V) RF OUTPUT OR INSTALLED BY CUSTOMER V) W300B1 E) HF-AUSGANG O) OPTION ODER INSTALLATION VOM KUNDEN 2096.7204.xx W1ADE MESSRICHTKOPPLER E) OPTION ADE AUTOMAT. ENTZERRUNG ADE SYSTEM KIT SX800Z1 2099.4006.01 V) OPTION VORSTUFEN SATZ SX800 ZR800V1 2099.1507.01 EXCITER STANDBY INSTALL KIT E) V) HIERZU SIEHE AUCH: 2098.5009.01 SA (ZR800C1) see also: 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) E) V) HF-BLOCKSCHALTBILD GUELTIG FUER VAR: SIEHE SCHALTTEILLISTE VALIED FOR MODELS: SEE PARTS LIST BLOCK DIAGRAM OF RF SIGNAL Benennung / Designat.: ROHDE&SCHWARZ NV8303X NV8303X BLITZSCHUTZ E) P14 GD800 X64 O) XMTR RF OUTPUT ak=+)dB ak=+)dB E) X23 1.RF DEMOD IN HF-SENDER AUFGANG P14B P14A ak= dB X2 V)W300B1 X60 RF OUTPUT X3 O) MESSRICHTKOPPLER DIRECTIONAL COUPLER A45 X.E2 A3 VH8300A1 UHF-VERSTAERKER X3 V) A100B SX800 TV EXCITER 2095.1502.xx X.E1 UHF AMPLIFIER P24 DACH TOP X3 X2 V)W304 V)A15 HF-SCHALTER UHF AMPLIFIER A2 VH8300A1 UHF-VERSTAERKER HF-SCHALTER IN POS:2 X64 X121B 10 MHz REF input -5...20dBm 50 BLATT 4: BLOCKSCHALTBILD STEUERLEITUNG sheet 4: block diagram of signal ABSORBERBLOCK X2 2095.3257.xx X143B X27 RF SWITCH 1PPS monitoring 75 A42 3-FACH-KOPPLER V) W300A1 2.RF DEMOD IN X142B 17 BLATT 3: NETZ-STROMLAUF MIT USV sheet 3: circuit diagram with UPS X22 W31A TS1 input 260mVpp...2Vpp 75 10 BLATT 2: NETZ-STROMLAUF sheet 2: circuit diagram V) EXCITER B BLATT 1: HF-BLOCKSCHALTBILD sheet 1: block diagram of rf signal 50 OHM 50 OHM ak= 60 dB 50 OHM Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved DACH TOP TS1 input 260mVpp...2Vpp 75 TS4 input 260mVpp...2Vpp 75 ak= 60 dB EXCITER A OPTION 10 11 12 13 NV8303X 14 Datum: Date: 08/07/18 DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 1+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0107.01 S 16 17 Q1 W3 W2 W1 L1 L2 L3 17 K3 1 NC NC GND GND GND GND GND X45.2 K1 1 K2 1 21 22 23 24 18 25 14 15 16 17 12 X45.1 11 GND GND GND +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS CL_DL_ON_OFF COOLING_ON_OFF +12V A31 NETZVERTEILUNG MITTELLEISTUNG Main distribution MP X20.1-3 16 +12V F1 L N PE 10 13 19 20 LOOP+_RESERVE LOOP-_COM LOOP+_MAIN FAULT2_ABS FAULT1_ABS FAULT2_CL 0V PRES 2 PRES 1 FAULT1_CL WARNING_CL X44. X10 OVERCUR_EXT_CL NICHT BELEGT NC + 12V X43. GND + 5V GND X42. PRES 2 X43B + 5V LINK GND LINK 15 GESTELLSTEUERUNG / Rack controller PRES 1 LINK 14 OPTION LUFTMAENGEN-MESSUNG air quantity measurement UEBERSTROM EXT KUEHLUNG overcurrent ext.cooling LINK X41. W.PE W4 LINK NICHT BELEGT not connected EXTERNAL POWER KIT 13 +12V X.PE1 12 +12V 11 +12V T1 T2 T3 10 RF LOOP SCHUTZSCHLEIFE Z1) OPTION ZR800Z1 2099.3000.xx BAUSATZ STECKDOSE EXTERN #) Z1) X57 + 5V STOERUNG KUEHLUNG 1 fault cooling 1 PE STOERUNG KUEHLUNG 2 fault cooling 2 230/400V AC L1 L2 L3 N NETZSTECKDOSE AC supply connector 230V AC max. 10A min.3x1qmm BETRIEBSERDE system ground STOERUNG GESTELL ABS fault rack abs 2098.0142.xx STOERUNG ANLAGEN ABS fault system abs VORSICHERUNG UND ANSCHLUSSQUERSCHNITT SIEHE SYSTEM-HANDBUCH NV8303E/V External fuseing and cable cross-sections see system manual NV8303E/V RESERVESENDER standby xmitter BETRIEBSSENDER main xmitter 2096.3009.xx L1 L2 L3 X1.1 X2. L1 W.L1 L2 W.L2 L3 W.L3 Q4X Q3X Q2 I>> I>> I>> I>> I>> I>> Q4 Q3 W61 X61 F7 3A 2 F8 3A 2 F5 3A 2 F1 3A 2 F2 3A 2 F3 3A 2 F4 3A 2 X6 X7 X8 X5 X1 X2 X3 X4 X1. X20.2 X62. X1. X63. U1 V1 W1 U1 V1 W1 U1 V1 W1 A2 VH8300A1 A3 VH8300A1 UHF AMPLIFIER UHF AMPLIFIER UHF AMPLIFIER UHF-VERSTAERKER UHF-VERSTAERKER UHF-VERSTAERKER C1A 8u 3 4 5 6 7 A1 VH8300A1 X1. XE1.1 2 K1 L2 X31. W31 W63 W62 E1 LUEFTER FAN 2096.2131.xx W4 X.N1 L3 X32. W32 XE2.1 2 K1 C2A 8u L3 X33. K2 L3 #) E2 LUEFTER FAN 2096.2131.xx L3 X36. #) 3 4 5 6 7 K3 #) OPTION STEUERBEFEHL FUER EXTERNE KUEHLUNG EIN control command for OPTION external cooling on STEUERBEFEHL FUER KUNSTANTENNE EIN control command for dummy load on OPTION NETZANSCHLUSS FUER EXTERNEN ABS - LUEFTER AC supply for external ABS cooling L1 X35. 1 2 W35 X45. 1 2 W45 ACL ACN L1 L1 L1 X34.1 W60 X52.52 53 54 55 71 81 Vout + Vout + W62C GND Vout Vout - NETZTEIL POWER SUPPLY 1081.0254.00 10 L1 +12V A 36 A35 VERTEILER-N-NETZ Interface Power N Distribution X.PE 2096.3550.xx X52.62 72 82 X.N3 X.N2 63 73 83 A200 NETCCU 800 11 A100A EXCITER A 12 PE Z2) OPTION ZR800Z2 2099.3100.xx BAUSATZ STECKDOSE INTERN V) OPTION ZR800V1 2099.1507.xx VORSTUFEN SATZ SX800 EXCITER B EXCITER STANDBY INSTALL KIT PE L N PE L N PE Z2) X55Z NV8303X 14 Datum: Date: 08/07/18 NETZ-STROMLAUF GUELTIG FUER VAR: SIEHE SCHALTTEILLISTE VALIED FOR MODELS: SEE PARTS LIST Benennung / Designat.: ROHDE&SCHWARZ NV8303X NV8303X 13 W155Z NETZANSCHLUSS FUER ZUSATZGERAETE AC supply for additional units A100B HIERZU SIEHE AUCH: 2098.5009.01 SA (ZR800C1) see also: 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) INTERN POWER POINT KIT 65 75 85 V) W62B W62A 64 74 84 #) INSTALLATION VOM KUNDEN #) installed by customer X20.1 F6 3A 2 X20.1 I>> I>> I>> X20.1 GND Q5X +12V Q2X X10.25 X1. X10.18 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved W3PH DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK CIRCUIT DIAGRAM Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 2+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0107.01 S 16 17 Q1 W3 W2 W1 L1 L2 L3 W.PE 13 X20.1-3 W4 23 W1PH W.N3 Z5) F1 L N PE 11 +12V K1 1 K2 1 K3 1 NC NC 21 22 23 24 18 25 14 15 16 17 12 GND GND GND GND +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS CL_DL_ON_OFF LOOP+_RESERVE COOLING_ON_OFF LOOP-_COM 10 LOOP+_MAIN 13 19 20 FAULT2_ABS FAULT1_ABS FAULT2_CL FAULT1_CL WARNING_CL 0V PRES 2 PRES 1 + 5V OVERCUR_EXT_CL NICHT BELEGT NC X44. + 12V GND + 5V X43. GND PRES 2 + 5V X42. X10 GND GND GND GND X45.2 A31 NETZVERTEILUNG MITTELLEISTUNG Main distribution MP X43B X45.1 X.PE2 LINK 17 GESTELLSTEUERUNG / Rack controller OPTION LUFTMAENGEN-MESSUNG air quantity measurement +12V 24 LINK 16 +12V X.PE1 LINK 15 +12V LINK X41. #) Z1) X57 LINK 14 +12V T1 T2 T3 Z5) Q1.1 14 EXTERNAL POWER KIT 13 GND #) 12 PRES 1 #) 11 UEBERSTROM EXT KUEHLUNG overcurrent ext.cooling PE 10 NICHT BELEGT not connected L1 L2 L3 N RF LOOP SCHUTZSCHLEIFE Z1) OPTION ZR800Z1 2099.3000.xx BAUSATZ STECKDOSE EXTERN NETZSTECKDOSE AC supply connector 230V AC max. 10A min.3x1qmm UPGRADE KIT EXTERNAL UPS STOERUNG KUEHLUNG 1 fault cooling 1 230/400V AC STOERUNG KUEHLUNG 2 fault cooling 2 BETRIEBSERDE system ground Z5) OPTION ZR800Z5 2099.3400.xx BAUSATZ EXTERNE USV STOERUNG GESTELL ABS fault rack abs 2098.0142.xx ACHTUNG !/ CAUTION ! NETZVERSORGUNG VON EXTERNER USV POWER SUPPLY FROM EXTERNAL UPS 230 AC max. 5A N PE STOERUNG ANLAGEN ABS fault system abs VORSICHERUNG UND ANSCHLUSSQUERSCHNITT SIEHE SYSTEM-HANDBUCH NV8303E/V External fuseing and cable cross-sections see system manual NV8303E/V RESERVESENDER standby xmitter BETRIEBSSENDER main xmitter 2096.3009.xx L1 L2 L3 X2. X1.1 X1. L2 W.L2 L3 W.L3 Q2 I>> I>> I>> Q4 Q3 I>> I>> I>> I>> I>> I>> W61 X61 F8 3A 2 F5 3A 2 F1 3A 2 F2 3A 2 F3 3A 2 F4 3A 2 X6 X7 X8 X5 X1 X2 X3 X4 X1. X62. X63. C1A 8u X1. X1. U1 V1 W1 U1 V1 W1 XE1.1 2 U1 V1 W1 3 4 5 6 7 A1 VH8300A1 UHF-VERSTAERKER UHF AMPLIFIER A2 VH8300A1 A3 VH8300A1 UHF AMPLIFIER UHF AMPLIFIER UHF-VERSTAERKER UHF-VERSTAERKER E1 LUEFTER FAN 2096.2131.xx K1 L2 X31. W31 W63 W62 X20.2 K1 L3 X32. W32 C2A 8u XE2.1 2 L3 X33. K2 #) E2 LUEFTER FAN 2096.2131.xx L3 L3 X36. #) 3 4 5 6 7 K3 #) OPTION STEUERBEFEHL FUER EXTERNE KUEHLUNG EIN control command for OPTION external cooling on STEUERBEFEHL FUER KUNSTANTENNE EIN control command for dummy load on OPTION NETZANSCHLUSS FUER EXTERNEN ABS - LUEFTER AC supply for external ABS cooling L N3 X35. 1 2 W35 W45 ACL ACN W62C GND Vout Vout - A 36 W60 X52.52 Vout + Vout + POWER SUPPLY 1081.0254.00 X34.1 +12V NETZTEIL 10 X.N3 A35 VERTEILER-N-NETZ Interface Power N Distribution X.PE N3 54 63 73 83 A200 NETCCU 800 11 A100A EXCITER A 12 Z2) OPTION ZR800Z2 2099.3100.xx BAUSATZ STECKDOSE INTERN V) V) OPTION ZR800V1 2099.1507.xx VORSTUFEN SATZ SX800 EXCITER B 13 EXCITER STANDBY INSTALL KIT W155Z NETZANSCHLUSS FUER ZUSATZGERAETE AC supply for additional units A100B HIERZU SIEHE AUCH: 2098.5009.01 SA (ZR800C1) see also: 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) INTERN POWER POINT KIT 65 75 85 64 74 84 PE 55 71 81 V) W62B W62A 53 L N3 #) INSTALLATION VOM KUNDEN #) installed by customer X.N2 X20.1 2096.3550.xx X52.62 72 82 X.N1 X45. 1 2 W4 F7 3A 2 X20.1 F6 3A 2 X20.1 Z5) W.N3 GND +12V Q5X Q4X X10.25 Q3X Q2X X10.18 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved W3PH PE L N PE L N PE Z2) X55Z DARSTELLUNG MIT NETZVERSORGUNG VON EXTERNER USV DESCRIPTION FOR POWER SUPPLY FROM EXTERNAL UPS ROHDE&SCHWARZ NV8303X NV8303X 14 Datum: Date: CIRCUIT DIAGRAM VALIED FOR MODELS: SEE PARTS LIST Benennung / Designat.: NV8303X NETZ-STROMLAUF GUELTIG FUER VAR: SIEHE SCHALTTEILLISTE 08/07/18 DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 3+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0107.01 S 16 17 1 10 11 12 X9 .1 X2 .1 .9 .9 .1 W59 X10 .9 .8 .1 X53A .1 CAN BUS ABSCHLUSSWIDERST. W56A X3 .8 .1 TERMINATING RESISTOR 2097.5628.00 ETHERNET A *) RS232 ETHERNET X7 X5 W48 A200 .8 .8 W47 .9 .9 .1 W55 ETHERNET B X12 .25 .1 X11 .15 X4 .1 X6 X10 .1 .9 V) W70 V) W56B .9 .1 .1 X2 .8 A50 .1 EXTERNE PUMPE CAN 3 NICHT BELEGT X5 PARALLEL REMOTE INTERFACE 2095.3257xx .15 3562.4210.xx 2099.1507.01 NOT CONNECTED X11 A3 VH8300A1 UHF-VERSTAERKER .1 W53D UHF AMPLIFIER 2095.6004.01 X53D CAN BUS ABSCHLUSSWIDERST. TERMINATING RESISTOR 2097.5605.00 HF-MESSSTELLEN RF PROBES NICHT BELEGT NOT CONNECTED X9 .1 .9 X6 X8 .25 .1 W52 X10 .25 .1 .9 2096.3550.xx 2095.1502.xx X43 .1 .2 W51B S.E2 DRUCKDOSE PRESSURE BOX 2077.3936.xx .3 .4 X41. 1 2 3 4 X42. 1 2 3 4 W45 Bruecke / Link .1 W51B .3 Bruecke / Link ABSORBER SCHUTZSCHLEIFE RF LOOP UEBERSTROM EXTERNE KUEHLUNG OVER CURRENT EXTERNAL COOLING PRESSURE BOX 2077.3936.xx .1 W51A .3 HIERZU SIEHE AUCH: see also: 2098.5009.01 SA (ZR800C1) 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) .1 X.Vout .4 Bruecke / Link A36 NETZTEIL POWER SUPPLY 1081.0254.00 see sheet 2,3 S.E1 DRUCKDOSE .1 X45 .4 X44. 1 2 W51A siehe Blatt 2,3 .1 .15 TV EXCITER 2095.6004.01 INTERFACE POWER N DISTRIBUTION ONLY BY SINGLE EXCITER UHF AMPLIFIER .15 EXTERNAL PUMP TV STEUERSENDER 2095.3305.xx A2 VH8300A1 UHF-VERSTAERKER VERTEILER-N-NETZ E) NUR BEI EINZEL-VORSTUFE .1 A35 EXCITER RF SWITCH FOR ADE EXCITER STANDBY INSTALL KIT 2095.6004.01 W53D 2096.4505.xx V) A100B SX800 VORST.SCHALTER FUER ADE V) ZR800V1 VORSTUFEN SATZ SX800 .15 .15 .1 .15 GESTELLSTEUERUNG .1 .1 V) A15 VORST.SCHALTER W53D .1 X4 .15 TON VERSTAERKER .9 CAN 2 ETHERNET EXCITER RF SWITCH X11 V) W54B 2097.5657.00 F) ZR800F1 PARALLELE-FERNSCHNITT-STELLE 2097.5611.00 W50 SOUND AMPLIFIER CAN 1 UHF AMPLIFIER TERMINATING RESISTOR W58AB .1 X7 .9 .1 E) X54B .9 .1 X7 .9 .8 DUMMY PLUG *) OPTION .20 X53B CAN BUS ABSCHLUSSWIDERST. RACK CONTROLLER 2095.8007.xx X12 BLINDSTECKER 2094.0260.xx TX CONTROL .1 ASI DISTRIBUTOR .9 .9 .9 2010.0006.xx W50 W53D .1 .9 VITIATED AIR SENSOR .9 .1 X11B .9 W50 .1 A60B ASI VERTEILER W58B W54A W55 .9 W55 X6 .1 NETCCU 800 .1 .1 .1 .1 X6 X100A ETHERNET REMOTE X232 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved .1 B2 ABLUFT SENSOR ETHERNET A1 VH8300A1 UHF-VERSTAERKER .20 X3 2096.6308.xx .9 DACH TOP 2094.0260.xx X2 RF REFLECTED ANT. W59 X2 W57 2095.1502.xx X2 GD800Z2 .1 P14B HF-RUECKLAUF ANT. X5 3562.3707.xx ASI DISTRIBUTOR .9 W50 X11 TV STEUERSENDER X53A REMOTE INTERFACE 2010.0006.xx W58A TV EXCITER X1 F) ZR800F1 .1 A57 FERNSCHNITTSTELLE INCOMING AIR SENSOR .1 A60A ASI VERTEILER X53D .9 X11 .9 .1 A100A SX800 .1 X2 2096.6308.xx TERMINATING RESISTOR W59 B1 ZULUFT SENSOR X2 2097.5628.00 RF FORWARD ANTENNA .1 X1 GD800Z2 P14A HF-VORLAUF ANT. X1 X53A CAN BUS ABSCHLUSSWIDERST. X11 .1 W53D ROHDE&SCHWARZ NV8303X NV8303X NV8303X Datum: Date: 08/07/18 BLOCKSCHALTBILD STEUERLEITUNG BLOCK DIAGRAM OF SIGNAL Benennung / Designat.: DTV-SENDER DTV XMTR Abteilung: Dept.: 10 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 4+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 11 2098.0107.01 S 12 1 X12 X53A 2097.5657.00 NETCCU 800 CAN_L 2 X12. SWI1_OS_POS_II 15 GND 16 BRUECKE SWI1_OS_PL 24 GND 25 BRUECKE X41 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved RF LOOP BETRIEBSSENDER MAIN XMITTER BRUECKE LINK NC R35B TX TX RX RX NC CAN_L 6 VERTEILER-N-NETZ X42. ABSORBER STOERUNG FAULT ABSORBER FAULT2_ABS 1 GND_0V 2 ANLAGE SYSTEM CAN_H 14 15 gn ge +12V +12V GND GND 4055.6458.00 ETHERNET REMOTE ASI VERTEILER A ASI DISTRIBUTOR A X11B. #) #) #) #) #)Bruecke auf GS X100A. X5. RACK CONTROLL UNIT 1 TX + 2 TX 3 RX + 6 RX - #) Link on PCB A60A X2. RACK NC X54B W53D 2097.5592.00 REDUCED_REF_B INTERFACE POWER DISTRIB. A35 X44. OVERCURRENT 1 _EXT_CL GND_0V 2 BRUECKE LINK UEBERSTROM EXT. KUEHLUNG GND A35 X10. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 W51AB 2097.5463.00 10 11 12 13 14 15 VERTEILER-NETZ BRUECKE INTERF: POWER DISTRIB. LINK A50 X3. A35 X43. W51B FAULT2_CL 1 GND_0V 2 WARNING_CL 6 GND_0V 7 W51A DRUCKDOSE PRESSURE BOX S.E2 S.E1 N.C. N.C. OVERCU_EXT_CL WARNING_CL FAULT1_CL FAULT2_CL FAULT1_ABS FAULT2_ABS LOOP+_MAIN LOOP_COM LOOP+_RESERVE GND_0V COOLING_ON_OFF CL_DL_ON_OFF +5V +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS SENSE+ PRES1 PERES2 GND GND GND GND SENSE- 13 W55 RACK CONTROLL UNIT 10 11 12 13 14 15 10 11 12 13 14 15 10 11 12 13 14 15 10 11 12 13 14 15 X6. X6. W54B +12V_RC N.C. GND LOOP-_EXC_A REDUCED_REF_A GND N.C. LOOP+_EXC_A +12V_RC A200 X7. 2097.5405.00 GESTELLSTEUERUNG SX800B EXCITER B RACK CONTROLL UNIT A100B A50 X7. X6. +12V_RC N.C. GND LOOP-_EXC_B REDUCED_REF_B GND N.C. LOOP+_EXC_B +12V_RC TX TX RX RX W56B A100B X2. RX RX TX TX 2097.5428.00 A50 X10. W58B W59 /SWI_EXC_POS1_A GND /SWI_EXC_SELECT2_B /SWI_EXC_POS2_B /SWI_EXC_SELECT3_B /SWI_EXC_POS3_B GND /SWI_EXC_SELECT1_B /SWI_EXC_POS1_B /SWI_EXC_SELECT2_A /SWI_EXC_POS2_A /SWI_EXC_SELECT3_A /SWI_EXC_POS3_A +12V_SWI_EXC NETCCU 800 A200 X10. B1.ZU B2.AB 2097.5457.00 HF-VORLAUF ANT. RF FORWARD ANTENNA P14A X1. HF-RUECKLAUF ANT. RF REFLECTED ANTENNA GND PEAK/AV1 +12V N.C. N.C. RF_PROBE1 ADJUST1 N.C. N.C. P14B X1. N.C. N.C. +12V PEAK/AV2 GND N.C. N.C. ADJUST2 RF_PROBE2 STROMLAUF DER STEUER-KABEL CIRCUIT DIAGRAM FROM THE SIGNAL CABLE ROHDE&SCHWARZ NV8303X NV8303X 13 10 11 12 13 14 15 Benennung / Designat.: 12 A15 X5. TEMPERATURE MONITOR *) OPTION 11 EXCITER RF SWITCH TEMPERATURFUEHLER W58A TV EXITER B A200 X4. TX TX RX RX N.C. CAN-L CAN_GND N.C. N.C. GND CAN-H N.C. CAN_V+ VORSTUFEN-SCHALTER RACK CONTROLL UNIT SX800 B ETHERNET B 17 2097.5370.00 10 11 12 13 14 15 X9. GESTELLSTEUERUNG 1139.2247.00 NETCCU 800 TX TX RX RX GND DGND AGND /AMPL_ERR RESET AMPL_ON VREF_PWR PEAK_AV PWR_OUT CAN_GND CAN_L CAN_H CAN_V+ /AC_OK NC SX800 A A200 X11. A200 W58AB A100A X2. NETCCU 800 TV EXITER A A200 X3. NETCCU 800 X1. +12V_RED CAN1_L CAN_GND +12V_RED CAN_SHLD GND CAN1_H +12V_ASI CAN_V+ 0041.9283.00 ETHERNET A W70 A57 A50 X2. NETCCU 800 X53D. 10 X53A. 16 *) 3562.3765.00 REMOTE INTERFACE GESTELLSTEUERUNG CAN BUS ABSCHL. RACK CONTROLL UNIT CAN BUS TERMINATING W56A CAN-Bus 10 11 12 13 14 15 W57 2097.5411.00 NETCCU 800 A50 A100A 15 FERNSCHNITTSTELLE UHF AMPLIFIER 10 11 12 13 14 15 14 GESTELLSTEUERUNG SX800A UHF-VERSTAERKER A3 A2 A5 A6 A1 A4 X11. X11. X11. X11. X11. X11. 10 11 12 13 14 15 12 2097.5392.00 EXCITER A 2097.5357.00 RACK CONTROLL UNIT OVERCURRENT EXT. COOLING INTERFACE POWER DISTRIBUTION GESTELLSTEUERUNG FAULT1_CL 3 20 120 OHM A50 X7. VERTEILER-N-NETZ +12V +12V R35D RACK CONTROLL UNIT 2097.5634.44 ASI 3 ASI 4 TERMINATING RESISTOR GESTELLSTEUERUNG X44 W54A VERTEILER-NETZ 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 20 LINK GESTELL A50 X8. A60B X2. 1 ASI 1 2 ASI 2 5 +12V 6 +12V 7 ASI 3 8 ASI 4 10 11 +12V 12 +12V 13 BRUECKE FAULT1_ABS 3 GND_0V 4 RACK CONTROLL UNIT ASI VERTEILER B ASI DISTRIBUTOR B 11 2097.5363.00 GESTELLSTEUERUNG CAN-BUS ABSCHLUSS-WIDERSTAND NC 10 W52 *) 2097.5386.00 GESTELLSTEUERUNG A50 X11. 2097.5605.00 X53D. 2097.5634.42 A36 X.P2 bn A200 TERMINATING RESISTOR X53D ETHERNET 120 OHM CAN_H 14 15 POWER SUPPLY NETCCU 800 STANDBY XMITTER INTERFACE POWER DISTRIB. CAN_L 6 CAN-BUS ABSCHLUSS-WIDERSTAND W50 NETZTEIL ws W48 2097.5611.00 RESERVESENDER A35 N.C. N.C. +12V GND NC X53B. SCHUTZSCHLEIFE X41. X42 A35 X45. 120 OHM 2096.3444.00 INTERFACE POWER N DISTRIB. TERMINATING RESISTOR X53B VERTEILER-N-NETZ LINK VERTEILER-N-NETZ LOOP-_RESER.3 LOOP_COM NC W45 R35A CAN_H 7 2097.5634.41 LOOP+_MAIN 1 LOOP_COM CAN-BUS ABSCHLUSS-WIDERSTAND LINK INTERFACE POWER DISTRIB. A35 2097.5628.00 X53A. TX CONTROL A200 NV8303X 14 Datum: Date: 08/07/18 DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 5+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0107.01 S 16 17 1 X33 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved INTERFACE POWER DISTRIB. A35 X31. L2 1 N 2 PE 3 230V AC X36. A35 X32. L3 1 N 2 PE 3 *) LINK AT PLUG INTERFACE POWER DISTRIB. A35 X34. X.E1 2 L2 4 N 7 PE C1A 8 L1 L1 L1 L1 PE E2 FAN CONNECTION bl/2 gnge 2 L3 4 N 7 PE C2A 8 NETZVERTEILUNG POWER DISTRIBUTION A31 Q2-Q7. X20.1-3 E1 FAN CONNECTION bl L2 2 N 4 PE 7 E2 W35 FAN *) o) E1 2096.3450.00 VERTEILER-NETZ A35 X35. sw *) bn L1 1 N 2 PE 3 gnge A200 NETCCU bn/1 bl/2 gnge W155Z 1 L1 2 N.C. 3 N PE A100B W62B SX800 B 2096.2131.01 E2 LUEFTERANSCHLUSS SX800 B TV EXCITER B AC VERTEILUNG ZUSATZGERAETE A100B X1. AC POWER DISTRIBUTION ADDITIONAL UNITS X52. bn/1 64 74 84 L1 PE bl/2 gnge 2097.5086.00 AC VERSORGUNG VERSTAERKER AC POWER SUPPLY AMPLIFIER A1-A6 X1. sw/1 W62C 1 L1 3 L2 4 L3 PE bl/2 bn/3 gnge 2097.4921.00 NETCCU 800 AC VERTEILUNG A200 X1. AC POWER DISTRIBUTION X52. bn/1 62 72 82 L1 PE bl/2 gnge 2097.5028.00 NETZANSCHLUSS FUER ZUSATZGERAETE AC VERTEILUNG 65 75 85 2097.4944.00 BIS / TO AC POWER DISTRIBUTION X52. gnge SX800 A POWER SUPPLY A36 X.P1 L1 PE bl/2 A100A NETZTEIL INTERFACE POWER DISTRIB. A100A X1. bn/1 63 73 83 2097.5034.00 W61-W66 E1 LUEFTERANSCHLUSS LUEFTER X52. X.E2 bn/1 SX800 A TV EXCITER A AC POWER DISTRIBUTION AC VERTEILUNG 2097.4938.00 AC VERTEILUNG AC POWER DISTRIBUTION 62 72 82 63 73 83 64 74 84 65 75 85 E2 LUEFTERANSCHLUSS 2096.2131.01 X.E1 52 53 54 55 71 81 X52. W62A 2097.4950.00 2096.3438.00 INTERFACE POWER DISTRIB. *) BRUECKE AM STECKER E1 gnge VERTEILER-NETZ E1 FAN CONNECTION bl/2 VERTEILER-NETZ NETZANSCHLUSS L3 1 EXT.ABS LUEFTER N 2 AC SUPPLY FOR PE 3 EXT. ABS COOLING W60 E1 LUEFTERANSCHLUSS bn/1 W32 2097.5634.36 2096.3421.00 VERTEILER-NETZ 230V AC STEUERBEFEHL L3 1 KUNSTANTENNE EIN N 2 CONTROL COMMAND PE 3 DUMMY LOAD ON X36 W31 2097.5634.33 X33. L3 1 STEUERBEFEHL EXT.KUEHLUNG EIN N 2 CONTROL COMMAND PE 3 EXT.COOLING ON AC SUPPLY FOR ADDITIONAL UNITS bn/1 L1 PE bl/2 gnge E2 FAN CONNECTION X.E2 L2 2 N 4 PE 7 LUEFTER bl FAN *) o) E2 STROMLAUF DER NETZ-KABEL sw CIRCUIT DIAGRAM FROM THE POWER CABLE *) bn Spr.:/Lang.: Aei:/C.I.: Benennung / Designat.: ROHDE&SCHWARZ NV8303X NV8303X gnge NV8303X Datum: Date: 08/07/18 DTV-SENDER DTV XMTR Abteilung: Dept.: 7TSK de 02.00 Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a Blatt:/Sh.: 6- 2098.0107.01 S el.Kennz Part Benennung / Hinweise Designation Sachnummer Stock No. Hersteller Manufacturer Bestellbezeichnung Designation enthalten in contained in ACHTUNG EGB /ATTENTION ESD Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision *VARIANTENERKLAERUNG *EXPLANATION OF MODELS VAR04=NV8303E DTV-SENDER MIT EINZEL-VORSTUFE PROGNOSESENDER MOD04=NV8303E DTVTRANSMITTER WITH SINGLE EXCITER VAR24=NV8303V DTV-SENDER MIT VORSTUFE-RESERVE OHNE ADE PROGNOSESENDER MOD24=NV8303V DTV TRANSMITTER WITH DUAL DRIVE WITHOUT ADE VAR50=NV8303X DTV-SENDER +++GRUNDSENDER+++ MOD50=NV8303X DTVTRANSMITTER ++BASIC TRANSMITTER++ A1 - A3 GG VH8300A1 UHF-VERSTAER. 3Phasig VH8300A1 UHF-AMPLIFIER VAR 04 24 2095.6004.02 2098.0107.01 A20 GS ZR800T1 EINBAUS. SX800 ZR800T1 INSTAL. KIT VAR 04 24 DTV - Ausfuehrung 2099.1007.03 2098.0107.01 A21 GS ZR800C1 LEISTUNGSSATZ ZR800C1 POWER KIT VAR 04 24 Leistungssatz fuer 3 Verstaerkern 2098.5009.43 2098.0107.01 A23 GS ZR800V1 VORST.SA SX800 ZR800V1 EXC.INST. KIT VAR 24 Vorstufensatz - DTV ohne ADE 2099.1507.04 2098.0107.01 A200 GG NETCCU 800 CONTROL UNIT NETCCU 800 CONTROL UNIT VAR 04 24 2095.8007.02 2098.0107.01 A100A GG SX800 TV EXCITER DTV UND ADE INT RF SX800 TV EXCITER VAR 04 24 2095.1502.71 2098.0107.01 A100B GG SX800 TV EXCITER DTV UND ADE INT RF SX800 TV EXCITER VAR 24 2095.1502.71 2098.0107.01 Benennung/Designation NV8303X DTV-SENDER NV8303X DTV XMTR NV8303X Datum/ Date 2008-01-17 Abt. / Dept. Sprach./Lang Ä.I. / C.I de en 01.00 Blatt/Sheet 1 of 1 Dokument Nr. / Document No. 7TSK Name / Name Ro 2098.0107.01 SA ROHDE & SCHWARZ A100A #) A100B 2000 A200 A1 A2 A3 Tiefe: 800 Depth: 800 600 Variantenerklärung siehe Schaltteilliste #) OPTION 01.00 Valid for model see parts list 01.08 RO 7TSK Tag Bearb. 01.08 Name RO Gepr. Norm S\DESI-DAT\NV8300\NV8303x ÄnderungsMitteilung NV8303x DTV-Sender Bd.IV/V DTV-TANSMITTER BD.IV/V Name zu Gerät Blatt-Nr. 2098.0107.01 ROHDE & SCHWARZ Tag Zeichn.-Nr. Änd. Zust. Benennung NV8303x reg. i. V. 2098.0107 V erste Z. 0000.0000.00 v. Bl. Broadcasting Division Drawings and Diagrams NV8304E/V 2098.0159.01 Printed in Germany 2098.0188.72 -4- E-1 7 TS2 input 260mVpp...2Vpp 75 TS3 input 260mVpp...2Vpp 75 W21A X20 X122A W22A X21 X123A W23A X25 X124A TS 1/2 monitoring 800mVpp -+30% 75 X131A TS 3/4 monitoring 800mVpp -+30% 75 X132A W24A X26 RF OUTPUT 4-FACH-SPLITTER A41 BV834H1 2096.4092.xx 4 TO 1 COUPLER A40 A100A SX800 TV EXCITER 2095.1502.xx 1 TO 4 SPLITTER X60 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved X141A 1PPS monitoring 75 X142A 10 MHz REF input -5...20dBm 50 X143A 2096.4005.xx V) W300A1 X22 W31A W32A A1 VH8300A1 UHF-VERSTAERKER X27 W41A W307A X10 15 16 X24 W42A X67 1.RF DEMOD IN X68 W43A E) V) W300A1 X.A2 X1 E) HF-SCHALTER IN POS:2 X64 V)R15A X4 RF SWITCH IN POSITION 2 W300 X2 W307B X.E TS2 input 260mVpp...2Vpp 75 X122B TS3 input 260mVpp...2Vpp 75 X123B TS4 input 260mVpp...2Vpp 75 X124B TS 1/2 monitoring 800mVpp -+30% 75 X131B V) W31B X22 TS 3/4 monitoring 800mVpp -+30% 75 X132B V) W32B X27 1PPS EXTERNAL input 50 X141B 10 MHz REF input -5...20dBm 50 X143B V) W21B X20 X.A3 W307C X10 V) W22B X21 X25 V) W23B V) W24B X26 V) W41B X1 W1 X1 Messausgang measuring output X11 X2 W2 X2 X12 X3 W3 X3 X13 2096.3909.xx X.A4 W307D X10 UHF AMPLIFIER X24 1.RF DEMOD IN 2.RF DEMOD IN V) W43B X3 2096.6508.01 P24 ak= dB OBERWELLENFILTER HARMONICS FILTER ak= dB P14D P14C BLITZSCHUTZ DIRECTIONAL COUPLER W2ADE E) X67 E) W3ADE E) V) X68 E) W4ADE E) V) RF OUTPUT O) OPTION ODER INSTALLATION VOM KUNDEN 2096.7204.xx OR INSTALLED BY CUSTOMER V) W300B1 E) HF-AUSGANG MESSRICHTKOPPLER X.E4 X2 W1ADE E) P14 GD800 E) X3 FILTER XMTR RF OUTPUT ak=+)dB ak=+)dB O) E) OPTION ADE AUTOMAT. ENTZERRUNG ADE SYSTEM KIT SX800Z1 2099.4006.01 V) OPTION VORSTUFEN SATZ SX800 ZR800V1 2099.1507.01 EXCITER STANDBY INSTALL KIT E) V) HIERZU SIEHE AUCH: 2098.5009.01 SA (ZR800C1) see also: 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) E) V) HF-BLOCKSCHALTBILD GUELTIG FUER VAR: SIEHE SCHALTTEILLISTE VALIED FOR MODELS: SEE PARTS LIST BLOCK DIAGRAM OF RF SIGNAL Benennung / Designat.: ROHDE&SCHWARZ NV8304X NV8304X O) MESSRICHTKOPPLER HF-SENDER AUFGANG P14B P14A X64 BLATT 6: STROMLAUF NETZKABEL sheet 6: circuit diagram power cable COUPLING ATTENUATION P14 SEE ALSO SYSTEM MANUAL A45 X.A X.E3 A4 VH8300A1 UHF-VERSTAERKER V)W300B1 X60 RF OUTPUT X3 X23 V) W42B +)AUSKOPPELDAEMPFUNG P14 SIEHE SYSTEM-HANDBUCH DACH TOP X.E2 UHF AMPLIFIER BLATT 5: STROMLAUF STEUERKABEL sheet 5: circuit diagram signal cable DIRECTIONAL COUPLER X2 X3 V) A100B SX800 TV EXCITER 2095.1502.xx UHF AMPLIFIER A3 VH8300A1 UHF-VERSTAERKER 2095.3257.xx X121B TERMINATION X3 X2 V)W304 V)A15 HF-SCHALTER X10 BLATT 4: BLOCKSCHALTBILD STEUERLEITUNG sheet 4: block diagram of signal ABSORBERBLOCK X.E1 A2 VH8300A1 UHF-VERSTAERKER RF SWITCH 1PPS monitoring 75 17 BLATT 3: NETZ-STROMLAUF MIT USV sheet 3: circuit diagram with UPS X2 2.RF DEMOD IN X142B UHF AMPLIFIER X23 TS1 input 260mVpp...2Vpp 75 14 A42 4-FACH-KOPPLER W300 V) EXCITER B 13 BLATT 2: NETZ-STROMLAUF sheet 2: circuit diagram 50 OHM 12 BLATT 1: HF-BLOCKSCHALTBILD sheet 1: block diagram of rf signal X.A1 11 50 OHM X121A 1PPS EXTERNAL input 50 10 ak= 60 dB 50 OHM DACH TOP TS1 input 260mVpp...2Vpp 75 TS4 input 260mVpp...2Vpp 75 ak= 60 dB EXCITER A OPTION 10 11 12 13 NV8304X 14 Datum: Date: 08/07/17 DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 1+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0159.01 S 16 17 Q1 W3 W2 W1 L1 L2 L3 17 K3 1 NC NC GND GND GND GND GND X45.2 K1 1 K2 1 21 22 23 24 18 25 14 15 16 17 12 X45.1 11 GND GND GND +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS CL_DL_ON_OFF COOLING_ON_OFF +12V A31 NETZVERTEILUNG MITTELLEISTUNG Main distribution MP X20.1-3 16 +12V F1 L N PE 10 13 19 20 LOOP+_RESERVE LOOP-_COM LOOP+_MAIN FAULT2_ABS FAULT1_ABS FAULT2_CL 0V PRES 2 PRES 1 FAULT1_CL WARNING_CL X44. X10 OVERCUR_EXT_CL NICHT BELEGT NC + 12V X43. GND + 5V GND X42. PRES 2 X43B + 5V LINK GND LINK 15 GESTELLSTEUERUNG / Rack controller PRES 1 LINK 14 OPTION LUFTMAENGEN-MESSUNG air quantity measurement UEBERSTROM EXT KUEHLUNG overcurrent ext.cooling LINK X41. W.PE W4 LINK NICHT BELEGT not connected EXTERNAL POWER KIT 13 +12V X.PE1 12 +12V 11 +12V T1 T2 T3 10 RF LOOP SCHUTZSCHLEIFE Z1) OPTION ZR800Z1 2099.3000.xx BAUSATZ STECKDOSE EXTERN #) Z1) X57 + 5V STOERUNG KUEHLUNG 1 fault cooling 1 PE STOERUNG KUEHLUNG 2 fault cooling 2 230/400V AC L1 L2 L3 N NETZSTECKDOSE AC supply connector 230V AC max. 10A min.3x1qmm BETRIEBSERDE system ground STOERUNG GESTELL ABS fault rack abs 2098.0194.xx STOERUNG ANLAGEN ABS fault system abs VORSICHERUNG UND ANSCHLUSSQUERSCHNITT SIEHE SYSTEM-HANDBUCH NV8304E/V External fuseing and cable cross-sections see system manual NV8304E/V RESERVESENDER standby xmitter BETRIEBSSENDER main xmitter 2096.3009.xx L1 L2 L3 X1.1 X2. L1 W.L1 L2 W.L2 L3 W.L3 Q4X Q2 I>> I>> I>> I>> I>> I>> Q4 Q3 Q5 I>> I>> I>> W61 X61 F7 3A 2 F8 3A 2 F5 3A 2 F1 3A 2 F2 3A 2 F3 3A 2 F4 3A 2 X6 X7 X8 X5 X1 X2 X3 X4 X1. W63 W62 X62. X1. X63. U1 V1 W1 X64. U1 V1 W1 U1 V1 W1 A2 VH8300A1 A3 VH8300A1 A4 VH8300A1 UHF AMPLIFIER UHF AMPLIFIER UHF AMPLIFIER UHF AMPLIFIER UHF-VERSTAERKER UHF-VERSTAERKER UHF-VERSTAERKER UHF-VERSTAERKER C1A 8u 3 4 5 6 7 A1 VH8300A1 X1. XE1.1 2 K1 L2 X31. W31 W64 X1. U1 V1 W1 X20.2 X20.2 E1 LUEFTER FAN 2096.2131.xx W4 X.N1 L3 X32. W32 XE2.1 2 K1 C2A 8u L3 X33. K2 L3 #) E2 LUEFTER FAN 2096.2131.xx L3 X36. #) 3 4 5 6 7 K3 #) OPTION STEUERBEFEHL FUER EXTERNE KUEHLUNG EIN control command for OPTION external cooling on STEUERBEFEHL FUER KUNSTANTENNE EIN control command for dummy load on OPTION NETZANSCHLUSS FUER EXTERNEN ABS - LUEFTER AC supply for external ABS cooling L1 X35. 1 2 W35 X45. 1 2 W45 ACL ACN L1 L1 L1 X34.1 W60 X52.52 53 54 55 71 81 Vout + Vout + W62C GND Vout Vout - NETZTEIL POWER SUPPLY 1081.0254.00 10 L1 +12V A 36 A35 VERTEILER-N-NETZ Interface Power N Distribution X.PE 2096.3550.xx X52.62 72 82 X.N3 X.N2 63 73 83 A200 NETCCU 800 11 A100A EXCITER A 12 PE Z2) OPTION ZR800Z2 2099.3100.xx BAUSATZ STECKDOSE INTERN V) OPTION ZR800V1 2099.1507.xx VORSTUFEN SATZ SX800 EXCITER B EXCITER STANDBY INSTALL KIT PE L N PE L N PE Z2) X55Z NV8304X 14 Datum: Date: 08/07/17 NETZ-STROMLAUF GUELTIG FUER VAR: SIEHE SCHALTTEILLISTE VALIED FOR MODELS: SEE PARTS LIST Benennung / Designat.: ROHDE&SCHWARZ NV8304X NV8304X 13 W155Z NETZANSCHLUSS FUER ZUSATZGERAETE AC supply for additional units A100B HIERZU SIEHE AUCH: 2098.5009.01 SA (ZR800C1) see also: 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) INTERN POWER POINT KIT 65 75 85 V) W62B W62A 64 74 84 #) INSTALLATION VOM KUNDEN #) installed by customer X20.1 F6 3A 2 X20.1 I>> I>> I>> X20.1 GND Q5X +12V Q3X Q2X X10.25 X1. X10.18 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved W3PH DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK CIRCUIT DIAGRAM Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 2+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0159.01 S 16 17 Q1 W3 W2 W1 L1 L2 L3 W.PE 13 X20.1-3 W4 23 W1PH 13 19 20 F1 L N PE 10 11 +12V K1 1 K2 1 K3 1 NC NC 21 22 23 24 18 25 14 15 16 17 12 GND GND GND GND +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS CL_DL_ON_OFF COOLING_ON_OFF LOOP+_RESERVE LOOP-_COM LOOP+_MAIN FAULT2_ABS FAULT1_ABS FAULT2_CL 0V PRES 2 PRES 1 FAULT1_CL + 5V UEBERSTROM EXT KUEHLUNG overcurrent ext.cooling X44. WARNING_CL X10 OVERCUR_EXT_CL NICHT BELEGT NC + 12V X43. GND + 5V GND X42. X43B PRES 2 LINK GESTELLSTEUERUNG / Rack controller OPTION LUFTMAENGEN-MESSUNG air quantity measurement + 5V X41. NICHT BELEGT not connected LINK 17 GND GND GND GND X45.2 A31 NETZVERTEILUNG MITTELLEISTUNG Main distribution MP LINK 16 X45.1 X.PE2 LINK 15 +12V 24 LINK 14 +12V X.PE1 EXTERNAL POWER KIT 13 +12V RF LOOP SCHUTZSCHLEIFE #) Z1) X57 12 +12V T1 T2 T3 Z5) Q1.1 14 11 GND #) 10 PRES 1 #) STOERUNG KUEHLUNG 1 fault cooling 1 PE Z1) OPTION ZR800Z1 2099.3000.xx BAUSATZ STECKDOSE EXTERN NETZSTECKDOSE AC supply connector 230V AC max. 10A min.3x1qmm UPGRADE KIT EXTERNAL UPS STOERUNG KUEHLUNG 2 fault cooling 2 L1 L2 L3 N NETZVERSORGUNG VON EXTERNER USV POWER SUPPLY FROM EXTERNAL UPS 230 AC max. 5A N PE BETRIEBSERDE system ground 230/400V AC Z5) OPTION ZR800Z5 2099.3400.xx BAUSATZ EXTERNE USV STOERUNG GESTELL ABS fault rack abs 2098.0194.xx ACHTUNG !/ CAUTION ! STOERUNG ANLAGEN ABS fault system abs VORSICHERUNG UND ANSCHLUSSQUERSCHNITT SIEHE SYSTEM-HANDBUCH NV8304E/V External fuseing and cable cross-sections see system manual NV8304E/V RESERVESENDER standby xmitter BETRIEBSSENDER main xmitter 2096.3009.xx W.N3 Z5) L1 L2 L3 X2. X1.1 X1. L2 W.L2 L3 W.L3 Q2 I>> I>> I>> Q4 Q3 Q5 I>> I>> I>> I>> I>> I>> I>> I>> I>> X20.1 W61 X61 F8 3A 2 F5 3A 2 F1 3A 2 F2 3A 2 F3 3A 2 F4 3A 2 X6 X7 X8 X5 X1 X2 X3 X4 X62. X63. X1. X1. U1 V1 W1 U1 V1 W1 X64. C1A 8u X1. U1 V1 W1 XE1.1 2 U1 V1 W1 3 4 5 6 7 A1 VH8300A1 UHF-VERSTAERKER UHF AMPLIFIER A2 VH8300A1 A3 VH8300A1 A4 VH8300A1 UHF AMPLIFIER UHF AMPLIFIER UHF AMPLIFIER UHF-VERSTAERKER UHF-VERSTAERKER UHF-VERSTAERKER E1 LUEFTER FAN 2096.2131.xx K1 L2 X31. W31 W64 K1 L3 X32. W32 C2A 8u XE2.1 2 L3 X33. K2 #) E2 LUEFTER FAN 2096.2131.xx L3 L3 X36. #) 3 4 5 6 7 K3 #) OPTION STEUERBEFEHL FUER EXTERNE KUEHLUNG EIN control command for OPTION external cooling on STEUERBEFEHL FUER KUNSTANTENNE EIN control command for dummy load on OPTION NETZANSCHLUSS FUER EXTERNEN ABS - LUEFTER AC supply for external ABS cooling L N3 X35. 1 2 W35 W45 ACL ACN W62C GND Vout Vout - A 36 W60 X52.52 Vout + Vout + POWER SUPPLY 1081.0254.00 X34.1 +12V NETZTEIL 10 X.N3 A35 VERTEILER-N-NETZ Interface Power N Distribution X.PE N3 A200 NETCCU 800 A100A EXCITER A 11 12 PE Z2) OPTION ZR800Z2 2099.3100.xx BAUSATZ STECKDOSE INTERN V) V) OPTION ZR800V1 2099.1507.xx VORSTUFEN SATZ SX800 EXCITER B 13 EXCITER STANDBY INSTALL KIT W155Z NETZANSCHLUSS FUER ZUSATZGERAETE AC supply for additional units A100B HIERZU SIEHE AUCH: 2098.5009.01 SA (ZR800C1) see also: 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) INTERN POWER POINT KIT 65 75 85 64 74 84 V) W62B W62A 55 71 81 54 63 73 83 53 L N3 #) INSTALLATION VOM KUNDEN #) installed by customer X.N2 X20.1 2096.3550.xx X52.62 72 82 X.N1 X45. 1 2 W4 F7 3A 2 X20.2 W63 W62 X1. X20.2 F6 3A 2 X20.1 Z5) W.N3 GND Q5X Q4X +12V Q3X X10.25 Q2X X10.18 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved W3PH PE L N PE L N PE Z2) X55Z DARSTELLUNG MIT NETZVERSORGUNG VON EXTERNER USV DESCRIPTION FOR POWER SUPPLY FROM EXTERNAL UPS ROHDE&SCHWARZ NV8304X NV8304X 14 Datum: Date: CIRCUIT DIAGRAM VALIED FOR MODELS: SEE PARTS LIST Benennung / Designat.: NV8304X NETZ-STROMLAUF GUELTIG FUER VAR: SIEHE SCHALTTEILLISTE 08/07/17 DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 3+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0159.01 S 16 17 1 10 11 12 .9 .9 X2 .1 .1 W59 X10 .9 .8 .1 X53A .1 CAN BUS ABSCHLUSSWIDERST. W56A X3 .8 .1 TERMINATING RESISTOR 2097.5628.00 ETHERNET A .8 *) RS232 W47 .9 ETHERNET X7 X5 W48 .1 .1 .1 .8 A200 .1 TX CONTROL .9 .1 W55 ETHERNET B X12 .25 .1 X11 .15 X12 BLINDSTECKER X4 .1 X10 .1 .9 V) W70 V) W56B .9 .1 .1 X2 .8 X5 2095.3257xx .15 EXCITER RF SWITCH PARALLEL REMOTE INTERFACE 3562.4210.xx .1 EXTERNE PUMPE CAN 3 NICHT BELEGT 2099.1507.01 NOT CONNECTED W53D HF-MESSSTELLEN UHF AMPLIFIER X11 .15 2095.6004.01 .1 A4 VH8300A1 UHF-VERSTAERKER .1 RF PROBES W53D NICHT BELEGT NOT CONNECTED X9 .1 .9 X6 X8 .25 .1 UHF AMPLIFIER 2095.6004.01 .15 X53D CAN BUS ABSCHLUSSWIDERST. TERMINATING RESISTOR 2097.5605.00 W52 X10 .25 .1 .9 2096.3550.xx 2095.1502.xx X43 .1 .2 W51B S.E2 DRUCKDOSE PRESSURE BOX 2077.3936.xx .3 .4 X41. 1 2 3 4 X42. 1 2 3 4 W45 Bruecke / Link .1 W51B .3 Bruecke / Link ABSORBER SCHUTZSCHLEIFE RF LOOP UEBERSTROM EXTERNE KUEHLUNG OVER CURRENT EXTERNAL COOLING PRESSURE BOX 2077.3936.xx .1 W51A .3 HIERZU SIEHE AUCH: see also: 2098.5009.01 SA (ZR800C1) 2099.1007.01 SA (ZR800T1) 2099.1507.01 SA (ZR800V1) 2095.1502.01 SA (SX800) 2095.8007.01 SA (NETCCU) .1 X.Vout .4 Bruecke / Link A36 NETZTEIL POWER SUPPLY 1081.0254.00 see sheet 2,3 S.E1 DRUCKDOSE .1 X45 .4 X44. 1 2 W51A siehe Blatt 2,3 A3 VH8300A1 UHF-VERSTAERKER .15 TV EXCITER .1 INTERFACE POWER N DISTRIBUTION ONLY BY SINGLE EXCITER 2095.6004.01 EXTERNAL PUMP TV STEUERSENDER 2095.3305.xx UHF AMPLIFIER .15 VERTEILER-N-NETZ E) NUR BEI EINZEL-VORSTUFE A2 VH8300A1 UHF-VERSTAERKER A35 EXCITER RF SWITCH FOR ADE EXCITER STANDBY INSTALL KIT .1 W53D 2096.4505.xx V) A100B SX800 VORST.SCHALTER FUER ADE V) ZR800V1 VORSTUFEN SATZ SX800 .1 .15 GESTELLSTEUERUNG .1 .1 V) A15 VORST.SCHALTER W53D .1 X4 .15 TON VERSTAERKER .9 A50 ETHERNET F) ZR800F1 PARALLELE-FERNSCHNITT-STELLE X11 V) W54B 2097.5657.00 *) OPTION 2097.5611.00 W50 CAN 2 CAN 1 2095.6004.01 TERMINATING RESISTOR SOUND AMPLIFIER .1 X7 .9 .1 E) X54B .9 .1 X7 .9 .8 DUMMY PLUG X6 X53B CAN BUS ABSCHLUSSWIDERST. RACK CONTROLLER 2095.8007.xx .1 .20 W58AB .9 .9 2094.0260.xx .9 W50 W53D .1 .9 2010.0006.xx ASI DISTRIBUTOR W54A W55 .9 W55 VITIATED AIR SENSOR .9 .1 X11B .9 W50 .1 A60B ASI VERTEILER W58B NETCCU 800 X6 X100A ETHERNET REMOTE X232 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved .1 X6 .1 UHF AMPLIFIER .15 X11 X9 .1 B2 ABLUFT SENSOR ETHERNET A1 VH8300A1 UHF-VERSTAERKER .20 X3 2096.6308.xx .9 DACH TOP 2094.0260.xx X2 RF REFLECTED ANT. W59 X2 W57 2095.1502.xx X2 GD800Z2 .1 P14B HF-RUECKLAUF ANT. X5 3562.3707.xx ASI DISTRIBUTOR .9 W50 X11 TV STEUERSENDER X53A REMOTE INTERFACE 2010.0006.xx W58A TV EXCITER X1 F) ZR800F1 .1 A57 FERNSCHNITTSTELLE INCOMING AIR SENSOR .1 A60A ASI VERTEILER X53D .9 X11 .9 .1 A100A SX800 .1 X2 2096.6308.xx TERMINATING RESISTOR W59 B1 ZULUFT SENSOR X2 2097.5628.00 RF FORWARD ANTENNA .1 X1 GD800Z2 P14A HF-VORLAUF ANT. X1 X53A CAN BUS ABSCHLUSSWIDERST. X11 .1 W53D ROHDE&SCHWARZ NV8304X NV8304X NV8304X Datum: Date: 08/07/17 BLOCKSCHALTBILD STEUERLEITUNG BLOCK DIAGRAM OF SIGNAL Benennung / Designat.: DTV-SENDER DTV XMTR Abteilung: Dept.: 10 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 4+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 11 2098.0159.01 S 12 1 X12 X53A 2097.5657.00 NETCCU 800 CAN_L 2 X12. SWI1_OS_POS_II 15 GND 16 BRUECKE SWI1_OS_PL 24 GND 25 BRUECKE X41 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved RF LOOP BETRIEBSSENDER MAIN XMITTER BRUECKE LINK NC R35B TX TX RX RX NC CAN_L 6 VERTEILER-N-NETZ X42. ABSORBER STOERUNG FAULT ABSORBER FAULT2_ABS 1 GND_0V 2 ANLAGE SYSTEM CAN_H 14 15 gn ge +12V +12V GND GND 4055.6458.00 ETHERNET REMOTE ASI VERTEILER A ASI DISTRIBUTOR A X11B. #) #) #) #) #)Bruecke auf GS X100A. X5. RACK CONTROLL UNIT 1 TX + 2 TX 3 RX + 6 RX - #) Link on PCB A60A X2. RACK NC X54B W53D 2097.5592.00 REDUCED_REF_B INTERFACE POWER DISTRIB. A35 X44. OVERCURRENT 1 _EXT_CL GND_0V 2 BRUECKE LINK UEBERSTROM EXT. KUEHLUNG GND A35 X10. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 W51AB 2097.5463.00 10 11 12 13 14 15 VERTEILER-NETZ BRUECKE INTERF: POWER DISTRIB. LINK A50 X3. A35 X43. W51B FAULT2_CL 1 GND_0V 2 WARNING_CL 6 GND_0V 7 W51A DRUCKDOSE PRESSURE BOX S.E2 S.E1 N.C. N.C. OVERCU_EXT_CL WARNING_CL FAULT1_CL FAULT2_CL FAULT1_ABS FAULT2_ABS LOOP+_MAIN LOOP_COM LOOP+_RESERVE GND_0V COOLING_ON_OFF CL_DL_ON_OFF +5V +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS +12V_AUX_PS SENSE+ PRES1 PERES2 GND GND GND GND SENSE- 13 W55 RACK CONTROLL UNIT 10 11 12 13 14 15 10 11 12 13 14 15 10 11 12 13 14 15 10 11 12 13 14 15 X6. X6. W54B +12V_RC N.C. GND LOOP-_EXC_A REDUCED_REF_A GND N.C. LOOP+_EXC_A +12V_RC A200 X7. 2097.5405.00 GESTELLSTEUERUNG SX800B EXCITER B RACK CONTROLL UNIT A100B A50 X7. X6. +12V_RC N.C. GND LOOP-_EXC_B REDUCED_REF_B GND N.C. LOOP+_EXC_B +12V_RC TX TX RX RX W56B A100B X2. RX RX TX TX 2097.5428.00 A50 X10. W58B W59 /SWI_EXC_POS1_A GND /SWI_EXC_SELECT2_B /SWI_EXC_POS2_B /SWI_EXC_SELECT3_B /SWI_EXC_POS3_B GND /SWI_EXC_SELECT1_B /SWI_EXC_POS1_B /SWI_EXC_SELECT2_A /SWI_EXC_POS2_A /SWI_EXC_SELECT3_A /SWI_EXC_POS3_A +12V_SWI_EXC NETCCU 800 A200 X10. B1.ZU B2.AB 2097.5457.00 HF-VORLAUF ANT. RF FORWARD ANTENNA P14A X1. HF-RUECKLAUF ANT. RF REFLECTED ANTENNA GND PEAK/AV1 +12V N.C. N.C. RF_PROBE1 ADJUST1 N.C. N.C. P14B X1. N.C. N.C. +12V PEAK/AV2 GND N.C. N.C. ADJUST2 RF_PROBE2 STROMLAUF DER STEUER-KABEL CIRCUIT DIAGRAM FROM THE SIGNAL CABLE ROHDE&SCHWARZ NV8304X NV8304X 13 10 11 12 13 14 15 Benennung / Designat.: 12 A15 X5. TEMPERATURE MONITOR *) OPTION 11 EXCITER RF SWITCH TEMPERATURFUEHLER W58A TV EXITER B A200 X4. TX TX RX RX N.C. CAN-L CAN_GND N.C. N.C. GND CAN-H N.C. CAN_V+ VORSTUFEN-SCHALTER RACK CONTROLL UNIT SX800 B ETHERNET B 17 2097.5370.00 10 11 12 13 14 15 X9. GESTELLSTEUERUNG 1139.2247.00 NETCCU 800 TX TX RX RX GND DGND AGND /AMPL_ERR RESET AMPL_ON VREF_PWR PEAK_AV PWR_OUT CAN_GND CAN_L CAN_H CAN_V+ /AC_OK NC SX800 A A200 X11. A200 W58AB A100A X2. NETCCU 800 TV EXITER A A200 X3. NETCCU 800 X1. +12V_RED CAN1_L CAN_GND +12V_RED CAN_SHLD GND CAN1_H +12V_ASI CAN_V+ 0041.9283.00 ETHERNET A W70 A57 A50 X2. NETCCU 800 X53D. 10 X53A. 16 *) 3562.3765.00 REMOTE INTERFACE GESTELLSTEUERUNG CAN BUS ABSCHL. RACK CONTROLL UNIT CAN BUS TERMINATING W56A CAN-Bus 10 11 12 13 14 15 W57 2097.5411.00 NETCCU 800 A50 A100A 15 FERNSCHNITTSTELLE UHF AMPLIFIER 10 11 12 13 14 15 14 GESTELLSTEUERUNG SX800A UHF-VERSTAERKER A3 A2 A5 A6 A1 A4 X11. X11. X11. X11. X11. X11. 10 11 12 13 14 15 12 2097.5392.00 EXCITER A 2097.5357.00 RACK CONTROLL UNIT OVERCURRENT EXT. COOLING INTERFACE POWER DISTRIBUTION GESTELLSTEUERUNG FAULT1_CL 3 20 120 OHM A50 X7. VERTEILER-N-NETZ +12V +12V R35D RACK CONTROLL UNIT 2097.5634.44 ASI 3 ASI 4 TERMINATING RESISTOR GESTELLSTEUERUNG X44 W54A VERTEILER-NETZ 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 20 LINK GESTELL A50 X8. A60B X2. 1 ASI 1 2 ASI 2 5 +12V 6 +12V 7 ASI 3 8 ASI 4 10 11 +12V 12 +12V 13 BRUECKE FAULT1_ABS 3 GND_0V 4 RACK CONTROLL UNIT ASI VERTEILER B ASI DISTRIBUTOR B 11 2097.5363.00 GESTELLSTEUERUNG CAN-BUS ABSCHLUSS-WIDERSTAND NC 10 W52 *) 2097.5386.00 GESTELLSTEUERUNG A50 X11. 2097.5605.00 X53D. 2097.5634.42 A36 X.P2 bn A200 TERMINATING RESISTOR X53D ETHERNET 120 OHM CAN_H 14 15 POWER SUPPLY NETCCU 800 STANDBY XMITTER INTERFACE POWER DISTRIB. CAN_L 6 CAN-BUS ABSCHLUSS-WIDERSTAND W50 NETZTEIL ws W48 2097.5611.00 RESERVESENDER A35 N.C. N.C. +12V GND NC X53B. SCHUTZSCHLEIFE X41. X42 A35 X45. 120 OHM 2096.3444.00 INTERFACE POWER N DISTRIB. TERMINATING RESISTOR X53B VERTEILER-N-NETZ LINK VERTEILER-N-NETZ LOOP-_RESER.3 LOOP_COM NC W45 R35A CAN_H 7 2097.5634.41 LOOP+_MAIN 1 LOOP_COM CAN-BUS ABSCHLUSS-WIDERSTAND LINK INTERFACE POWER DISTRIB. A35 2097.5628.00 X53A. TX CONTROL A200 NV8304X 14 Datum: Date: 08/07/17 DTV-SENDER DTV XMTR Abteilung: Dept.: 15 7TSK Spr.:/Lang.: Aei:/C.I.: de 02.00 Blatt:/Sh.: 5+ Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a 2098.0159.01 S 16 17 1 X33 Fuer dieses Dokument behalten wir uns alle Rechte vor For this document all rights are reserved INTERFACE POWER DISTRIB. A35 X31. L2 1 N 2 PE 3 230V AC X36. A35 X32. L3 1 N 2 PE 3 *) LINK AT PLUG INTERFACE POWER DISTRIB. A35 X34. X.E1 2 L2 4 N 7 PE C1A 8 L1 L1 L1 L1 PE E2 FAN CONNECTION bl/2 gnge 2 L3 4 N 7 PE C2A 8 NETZVERTEILUNG POWER DISTRIBUTION A31 Q2-Q7. X20.1-3 E1 FAN CONNECTION bl L2 2 N 4 PE 7 E2 W35 FAN *) o) E1 2096.3450.00 VERTEILER-NETZ A35 X35. sw *) bn L1 1 N 2 PE 3 gnge A200 NETCCU bn/1 bl/2 gnge W155Z 1 L1 2 N.C. 3 N PE A100B W62B SX800 B 2096.2131.01 E2 LUEFTERANSCHLUSS SX800 B TV EXCITER B AC VERTEILUNG ZUSATZGERAETE A100B X1. AC POWER DISTRIBUTION ADDITIONAL UNITS X52. bn/1 64 74 84 L1 PE bl/2 gnge 2097.5086.00 AC VERSORGUNG VERSTAERKER AC POWER SUPPLY AMPLIFIER A1-A6 X1. sw/1 W62C 1 L1 3 L2 4 L3 PE bl/2 bn/3 gnge 2097.4921.00 NETCCU 800 AC VERTEILUNG A200 X1. AC POWER DISTRIBUTION X52. bn/1 62 72 82 L1 PE bl/2 gnge 2097.5028.00 NETZANSCHLUSS FUER ZUSATZGERAETE AC VERTEILUNG 65 75 85 2097.4944.00 BIS / TO AC POWER DISTRIBUTION X52. gnge SX800 A POWER SUPPLY A36 X.P1 L1 PE bl/2 A100A NETZTEIL INTERFACE POWER DISTRIB. A100A X1. bn/1 63 73 83 2097.5034.00 W61-W66 E1 LUEFTERANSCHLUSS LUEFTER X52. X.E2 bn/1 SX800 A TV EXCITER A AC POWER DISTRIBUTION AC VERTEILUNG 2097.4938.00 AC VERTEILUNG AC POWER DISTRIBUTION 62 72 82 63 73 83 64 74 84 65 75 85 E2 LUEFTERANSCHLUSS 2096.2131.01 X.E1 52 53 54 55 71 81 X52. W62A 2097.4950.00 2096.3438.00 INTERFACE POWER DISTRIB. *) BRUECKE AM STECKER E1 gnge VERTEILER-NETZ E1 FAN CONNECTION bl/2 VERTEILER-NETZ NETZANSCHLUSS L3 1 EXT.ABS LUEFTER N 2 AC SUPPLY FOR PE 3 EXT. ABS COOLING W60 E1 LUEFTERANSCHLUSS bn/1 W32 2097.5634.36 2096.3421.00 VERTEILER-NETZ 230V AC STEUERBEFEHL L3 1 KUNSTANTENNE EIN N 2 CONTROL COMMAND PE 3 DUMMY LOAD ON X36 W31 2097.5634.33 X33. L3 1 STEUERBEFEHL EXT.KUEHLUNG EIN N 2 CONTROL COMMAND PE 3 EXT.COOLING ON AC SUPPLY FOR ADDITIONAL UNITS bn/1 L1 PE bl/2 gnge E2 FAN CONNECTION X.E2 L2 2 N 4 PE 7 LUEFTER bl FAN *) o) E2 STROMLAUF DER NETZ-KABEL sw CIRCUIT DIAGRAM FROM THE POWER CABLE *) bn Spr.:/Lang.: Aei:/C.I.: Benennung / Designat.: ROHDE&SCHWARZ NV8304X NV8304X gnge NV8304X Datum: Date: 08/07/17 DTV-SENDER DTV XMTR Abteilung: Dept.: 7TSK de 02.00 Zeichn.Nr.:/Drawing No.: Name: Name: rolf_a Blatt:/Sh.: 6- 2098.0159.01 S el.Kennz Part Benennung / Hinweise Designation Sachnummer Stock No. Hersteller Manufacturer Bestellbezeichnung Designation enthalten in contained in ACHTUNG EGB /ATTENTION ESD Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision *VARIANTENERKLAERUNG *EXPLANATION OF MODELS VAR04=NV8304E DTV-SENDER MIT EINZEL-VORSTUFE PROGNOSESENDER MOD04=NV8304E DTVTRANSMITTER WITH SINGLE EXCITER VAR24=NV8304V DTV-SENDER MIT VORSTUFE-RESERVE OHNE ADE PROGNOSESENDER MOD24=NV8304V DTV TRANSMITTER WITH DUAL DRIVE WITHOUT ADE VAR50=NV8304X DTV-SENDER +++GRUNDSENDER+++ MOD50=NV8304X DTVTRANSMITTER ++BASIC TRANSMITTER++ A1 - A4 GG VH8300A1 UHF-VERSTAER. 3Phasig VH8300A1 UHF-AMPLIFIER VAR 04 24 2095.6004.02 2098.0159.01 A20 GS ZR800T1 EINBAUS. SX800 ZR800T1 INSTAL. KIT VAR 04 24 DTV - Ausfuehrung 2099.1007.03 2098.0159.01 A21 GS ZR800C1 LEISTUNGSSATZ ZR800C1 POWER KIT VAR 04 24 Leistungssatz fuer 4 Verstaerkern 2098.5009.44 2098.0159.01 A23 GS ZR800V1 VORST.SA SX800 ZR800V1 EXC.INST. KIT VAR 24 Vorstufensatz - DTV ohne ADE 2099.1507.04 2098.0159.01 A200 GG NETCCU 800 CONTROL UNIT NETCCU 800 CONTROL UNIT VAR 04 24 2095.8007.02 2098.0159.01 A100A GG SX800 TV EXCITER DTV UND ADE INT RF SX800 TV EXCITER VAR 04 24 2095.1502.71 2098.0159.01 A100B GG SX800 TV EXCITER DTV UND ADE INT RF SX800 TV EXCITER VAR 24 2095.1502.71 2098.0159.01 Benennung/Designation NV8304X DTV-SENDER NV8304X DTV XMTR NV8304X Datum/ Date 2008-01-17 Abt. / Dept. Sprach./Lang Ä.I. / C.I de en 01.00 Blatt/Sheet 1 of 1 Dokument Nr. / Document No. 7TSK Name / Name Ro 2098.0159.01 SA ROHDE & SCHWARZ A100A #) A100B 2000 A200 A1 A2 A3 A4 Tiefe: 800 Depth: 800 600 Variantenerklärung siehe Schaltteilliste #) OPTION 01.00 Valid for model see parts list 01.08 RO 7TSK Tag Bearb. 01.08 Name RO Gepr. Norm S\DESI-DAT\NV8300\NV8304x ÄnderungsMitteilung NV8304x DTV-Sender Bd.IV/V DTV-TANSMITTER BD.IV/V Name zu Gerät Blatt-Nr. 2098.0159.01 ROHDE & SCHWARZ Tag Zeichn.-Nr. Änd. Zust. Benennung NV8304x reg. i. V. 2098.0159 V erste Z. 0000.0000.00 v. Bl. Broadcasting Division Spare Parts Lists TRANSMITTERS Printed in Germany 2098.0188.72 -5- E-1 Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH ACHTUNG EGB/ATTENTION ESD *VARIANTENERKLAERUNG *EXPLANATION OF MODELS Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision VAR11=MIT 1 VERSTAERKER BAND III MOD11=WITH 1 AMPLIFIER BAND III VAR12=MIT 2 VERSTAERKER BAND III MOD12=WITH 2 AMPLIFIER BAND III VAR13=MIT 3 VERSTAERKER BAND III MOD13=WITH 3 AMPLIFIER BAND III VAR14=MIT 4 VERSTAERKER BAND III MOD14=WITH 4 AMPLIFIER BAND III VAR15=MIT 5 VERSTAERKER BAND III MOD15=WITH 5 AMPLIFIER BAND III VAR16=MIT 6 VERSTAERKER BAND III MOD16=WITH 6 AMPLIFIER BAND III VAR21=MIT 1 VERSTAERKER BAND IV/V MOD21=WITH 1 AMPLIFIER BAND IV/V VAR22=MIT 2 VERSTAERKER BAND IV/V MOD22=WITH 2 AMPLIFIER BAND IV/V VAR23=MIT 3 VERSTAERKER BAND IV/V MOD23=WITH 3 AMPLIFIER BAND IV/V VAR24=MIT 4 VERSTAERKER BAND IV/V MOD24=WITH 4 AMPLIFIER BAND IV/V VAR25=MIT 5 VERSTAERKER BAND IV/V MOD25=WITH 5 AMPLIFIER BAND IV/V VAR26=MIT 6 VERSTAERKER BAND IV/V MOD26=WITH 6 AMPLIFIER BAND IV/V VAR31=FUER NX8300 MIT 1 VERSTAERKER BAND III MOD31=FOR NX8300 WITH 1 AMPLIFIER BAND III VAR32=FUER NX8300 MIT 2 VERSTAERKER BAND III MOD32=FOR NX8300 WITH 2 AMPLIFIER BAND III VAR33=FUER NX8300 MIT 3 VERSTAERKER BAND III MOD33=FOR NX8300 WITH 3 AMPLIFIER BAND III VAR34=FUER NX8300 MIT 4 VERSTAERKER BAND III MOD34=FOR NX8300 WITH 4 AMPLIFIER BAND III VAR35=FUER NX8300 MIT 5 VERSTAERKER BAND III MOD35=FOR NX8300 WITH 5 AMPLIFIER BAND III VAR36=FUER NX8300 MIT 6 VERSTAERKER BAND III MOD36=FOR NX8300 WITH 6 AMPLIFIER BAND III VAR41=FUER NX8300 MIT 1 VERSTAERKER BAND IV/V MOD41=FOR NX8300 WITH 1 AMPLIFIER BAND IV/V VAR42=FUER NX8300 MIT 2 VERSTAERKER BAND IV/V MOD42=FOR NX8300 WITH 2 AMPLIFIER BAND IV/V VAR43=FUER NX8300 MIT 3 VERSTAERKER BAND IV/V MOD43=FOR NX8300 WITH 3 AMPLIFIER BAND IV/V VAR44=FUER NX8300 MIT 4 VERSTAERKER BAND IV/V MOD44=FOR NX8300 WITH 4 AMPLIFIER BAND IV/V VAR45=FUER NX8300 MIT 5 VERSTAERKER BAND IV/V MOD45=FOR NX8300 WITH 5 AMPLIFIER BAND IV/V VAR46=FUER NX8300 MIT 6 VERSTAERKER BAND IV/V Benennung/Designation ERSATZTEILLISTE ZR800C1 LEISTUNGSS. SPARE PART LIST FOR 2098.5009.01 ZR800C1 Datum/ Date 2009-07-09 Abt. / Dept. 7TSK Name / Name RO Sprach./Lang Ä.I. / C.I de en 04.00 Blatt/Sheet 1 of 10 Dokument Nr. / Document No. 2098.5067.01 ST _ Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH 0999.9610.00 MOD46=FOR NX8300 WITH 6 AMPLIFIER BAND IV/V VAR51=FUER NX8300X1 MIT 1 VERSTAERKER BAND III MOD51=FOR NX8300X1 WITH 1 AMPLIFIER BAND III VAR52=FUER NX8300X1 MIT 2 VERSTAERKER BAND III MOD52=FOR NX8300X1 WITH 2 AMPLIFIER BAND III VAR53=FUER NX8300X1 MIT 3 VERSTAERKER BAND III MOD53=FOR NX8300X1 WITH 3 AMPLIFIER BAND III VAR54=FUER NX8300X1 MIT 4 VERSTAERKER BAND III MOD54=FOR NX8300X1 WITH 4 AMPLIFIER BAND III VAR55=FUER NX8300X1 MIT 5 VERSTAERKER BAND III MOD55=FOR NX8300X1 WITH 5 AMPLIFIER BAND III VAR56=FUER NX8300X1 MIT 6 VERSTAERKER BAND III MOD56=FOR NX8300X1 WITH 6 AMPLIFIER BAND III VAR61=FUER NX8300X1 MIT 1 VERSTAERKER BAND IV/V MOD61=FOR NX8300X1 WITH 1 AMPLIFIER BAND IV/V VAR62=FUER NX8300X1 MIT 2 VERSTAERKER BAND IV/V MOD62=FOR NX8300X1 WITH 2 AMPLIFIER BAND IV/V VAR63=FUER NX8300X1 MIT 3 VERSTAERKER BAND IV/V MOD63=FOR NX8300X1 WITH 3 AMPLIFIER BAND IV/V VAR64=FUER NX8300X1 MIT 4 VERSTAERKER BAND IV/V MOD64=FOR NX8300X1 WITH 4 AMPLIFIER BAND IV/V VAR65=FUER NX8300X1 MIT 5 VERSTAERKER BAND IV/V MOD65=FOR NX8300X1 WITH 5 AMPLIFIER BAND IV/V VAR66=FUER NX8300X1 MIT 6 VERSTAERKER BAND IV/V MOD66=FOR NX8300X1 WITH 6 AMPLIFIER BAND IV/V 1000 0 PB BEMERKUNG NOTE Pos.: 1010 bis 1990 HF - Komponenten 1020 1 A41 ZE BV822M1 2FACH-KOPPLER BV822M1 TWOF. COUPLER VAR 12 32 52 ## Verwendet in: ## 2098.5009.01 2099.5502.02 1030 1 A41 ZE BV823M1 3FACH-KOPPLER BV823M1 3F. COUPLER VAR 13 33 53 ## Verwendet in: ## 2098.5009.01 2099.5702.02 1040 1 A41 ZE BV824M1 4FACH-KOPPLER BV824M1 QUADRUPLE COUPLER VAR 14 34 54 ## Verwendet in: ## 2098.5009.01 2099.5602.02 1050 1 A41 ZE BV825M1 5FACH-KOPPLER 2099.5802.02 Benennung/Designation ERSATZTEILLISTE ZR800C1 LEISTUNGSS. SPARE PART LIST FOR 2098.5009.01 ZR800C1 Datum/ Date 2009-07-09 Abt. / Dept. 7TSK Name / Name RO Sprach./Lang Ä.I. / C.I de en 04.00 Blatt/Sheet 2 of 10 Dokument Nr. / Document No. 2098.5067.01 ST Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision BV825M1 5F. COUPLER VAR 15 35 55 ## Verwendet in: ## 2098.5009.01 1060 1 A41 ZE BV826M1 6FACH-KOPPLER BV826M1 6F. COUPLER VAR 16 36 56 ## Verwendet in: ## 2098.5009.01 2099.5902.02 1120 1 A41 ZE BV832H1 2FACH-KOPPLER BV832H1 2 WAY COUPLER VAR 22 42 62 ## Verwendet in: ## 2098.5009.01 2096.4305.02 1130 1 A41 ZE BV833H1 3FACH-KOPPLER BV833H1 TRIPLE COUPLER VAR 23 43 63 ## Verwendet in: ## 2098.5009.01 2096.4157.02 1140 1 A41 ZE BV834H1 4FACH-KOPPLER BV834H1 FOURFOLD COUPL VAR 24 44 64 ## Verwendet in: ## 2098.5009.01 2096.4005.02 1150 1 A41 ZE BV835H1 5FACH-KOPPLER BV835H1 FIVEFOLD COUPL VAR 25 45 65 ## Verwendet in: ## 2098.5009.01 2096.4705.02 1160 1 A41 ZE BV836H1 6FACH-KOPPLER BV836H1 SIXFOLD COUPL. VAR 26 46 66 ## Verwendet in: ## 2098.5009.01 2096.3750.02 1220 1 A42 ZE ABS-BLOCK ML NX8000 ABS BLOCK MP NX8000 VAR 12 13 32 33 52 53 ## Verwendet in: ## 2098.5009.01 2096.3909.32 1240 1 A42 ZE ABS-BLOCK ML NX8000 ABS BLOCK MP NX8000 VAR 14 15 16 34 35 36 54 55 56 ## Verwendet in: ## 2098.5009.01 2096.3909.35 1320 1 A42 ZE ABS-BLOCK ML NX8000 ABS BLOCK MP NX8000 VAR 22 23 42 43 62 63 ## Verwendet in: ## 2098.5009.01 2096.3909.03 1340 1 A42 ZE ABS-BLOCK ML NX8000 ABS BLOCK MP NX8000 VAR 24 25 26 44 45 46 64 65 66 ## Verwendet in: ## 2098.5009.01 2096.3909.02 1410 1 A45 ZM FM825 OWF - BD. 3 FM825 H.FILT. BD. 3 VAR 11 12 13 14 15 16 31 32 33 34 35 36 51 52 53 54 55 56 ## Verwendet in: ## 2098.5009.01 2096.7304.00 1450 1 A45 ZM FH825 OWF - BD. 4/5 FH825 H.FILT. BD. 4/5 2096.6508.02 Benennung/Designation ERSATZTEILLISTE ZR800C1 LEISTUNGSS. SPARE PART LIST FOR 2098.5009.01 ZR800C1 Datum/ Date 2009-07-09 Abt. / Dept. 7TSK Name / Name RO Sprach./Lang Ä.I. / C.I de en 04.00 Blatt/Sheet 3 of 10 Dokument Nr. / Document No. 2098.5067.01 ST Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision VAR 21 22 23 24 25 26 41 42 43 44 45 46 61 62 63 64 65 66 ## Verwendet in: ## 2098.5009.01 1510 1 P14 ZE GD800 MESSRICHTKOPPLER DIRECTION COUPLER VAR 11 12 13 14 15 16 31 32 33 34 35 36 51 52 53 54 55 56 ## Verwendet in: ## 2098.5009.01 2096.7204.34 1520 1 P14 ZE GD800 MESSRICHTKOPPLER DIRECTION COUPLER VAR 21 22 23 24 25 26 41 42 43 44 45 46 61 62 63 64 65 66 ## Verwendet in: ## 2098.5009.01 2096.7204.44 1530 1 P14A ZM GD800Z2 MESSSYSTEM GD800Z2 MEASURING SYST VAR 11 12 13 14 15 16 31 32 33 34 35 36 51 52 53 54 55 56 ## Verwendet in: ## 2096.7204.01 2096.6308.30 1540 1 P14A ZM GD800Z2 MESSSYSTEM GD800Z2 MEASURING SYST VAR 21 22 23 24 25 26 41 42 43 44 45 46 61 62 63 64 65 66 ## Verwendet in: ## 2096.7204.01 2096.6308.40 1550 1 P14B ZM GD800Z2 MESSSYSTEM GD800Z2 MEASURING SYST VAR 11 12 13 14 15 16 31 32 33 34 35 36 51 52 53 54 55 56 ## Verwendet in: ## 2096.7204.01 2096.6308.30 1560 1 P14B ZM GD800Z2 MESSSYSTEM GD800Z2 MEASURING SYST VAR 21 22 23 24 25 26 41 42 43 44 45 46 61 62 63 64 65 66 ## Verwendet in: ## 2096.7204.01 2096.6308.40 1570 1 P14C ZM GD800Z1 MESSSYSTEM GD800Z1 MEASURING SYST ## Verwendet in: ## 2096.7204.01 2096.6208.02 1580 1 P14D ZM GD800Z1 MESSSYSTEM GD800Z1 MEASURING SYST ## Verwendet in: ## 2096.7204.01 2096.6208.03 1590 1 P14ZP ED RF-AUSGANG Z2 RF_OUTPUT Z2 ## Verwendet in: ## 2096.7204.01 Zum Einstellen der Auskoppeldaempfung fuer P14A, P14B, P14C und P14D. 2096.6408.02 1610 1 W.A1 DH KABEL L=1M S/S 7/16 CABLE VAR 11 21 31 41 51 61 ## Verwendet in: ## 2098.5009.01 2087.7111.00 1620 1 X.A ZM UEBERGANG 7/16BU-RL13/30M Adaptor 7/16BU-RL13/30M VAR 11 21 31 41 51 61 ## Verwendet in: ## 2098.5009.01 2096.7004.00 Benennung/Designation ERSATZTEILLISTE ZR800C1 LEISTUNGSS. SPARE PART LIST FOR 2098.5009.01 ZR800C1 Datum/ Date 2009-07-09 Abt. / Dept. 7TSK Name / Name RO Sprach./Lang Ä.I. / C.I de en 04.00 Blatt/Sheet 4 of 10 Dokument Nr. / Document No. 2098.5067.01 ST _ Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH 1630 1 DV RG400 2XN/W U 1,4M RF-CABLE VAR 12 13 14 15 16 22 23 24 25 26 32 33 34 35 36 42 43 44 45 46 52 53 54 55 56 62 63 64 65 66 ## Verwendet in: ## 2098.5009.01 2097.5792.00 1640 1 DV RG400 2XN/W U 0,6M RF-CABLE VAR 15 16 25 26 35 36 45 46 55 56 65 66 ## Verwendet in: ## 2098.5009.01 2097.5805.00 1650 1 DH KABEL SCF 2XN-W 1.1M U RF CABLE VAR 14 15 16 24 25 26 34 35 36 44 45 46 54 55 56 64 65 66 ## Verwendet in: ## 2098.5009.01 2097.5863.00 1710 1 ZM UEBERGANG 1 5/8EIA-RL13/30R Adaptor 1 5/8EIA-RL13/30R ## Verwendet in: ## 2098.5009.01 2096.6966.00 1720 1 FK KUPPLUNG EIA 1 5/8 ADAPTOR FOR TRANSMISSION LINE 1 5/8 ## Verwendet in: ## 2098.5009.01 0656.2279.00 2000 0 PB BEMERKUNG NOTE Pos.: 2010 bis 2990 Netzverteilung - Komponenten 0999.9610.00 2010 1 X1 SL 3PH SAM.SCH. EINSP. LI 3PH CURR. DISTRIB. LEF VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3009.01 2096.5053.00 2020 1 X1.1 SL 3PH SAM.SCH. ERWEIT.2X 3PH CURR. DISTRIB. 2X VAR 13 14 16 23 24 26 33 34 36 43 44 46 ## Verwendet in: ## 2096.3344.01 2096.5060.00 X1.2 2030 1 X1.1 SL 3PH SAM.SCH. ERWEIT.3X 3PH CURR. DISTRIB. 3X VAR 15 25 36 46 ## Verwendet in: ## 2096.3344.01 2096.5076.00 2040 1 X2 VK KLEMMBLOCK 0.5-6QMM TERMINAL BLOCK VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3009.01 2096.5124.00 2050 1 F1 SS SCHUTZSCHALTER T-M 1P 3A - C PROTECT SWITCH 1P 3A - C VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3009.01 2096.5030.00 F2 F3 F4 F5 F6 Benennung/Designation ERSATZTEILLISTE ZR800C1 LEISTUNGSS. SPARE PART LIST FOR 2098.5009.01 ZR800C1 Datum/ Date 2009-07-09 Abt. / Dept. 7TSK Name / Name RO Sprach./Lang Ä.I. / C.I de en 04.00 Blatt/Sheet 5 of 10 Dokument Nr. / Document No. 2098.5067.01 ST Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision F7 F8 2090 1 W1PH DX W1PH VERTEILER N-NETZ W1PH MAIN DISTRIBUTOR VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3009.01 2096.3538.02 2110 1 Q1 SL LEISTUNGSTRENNER 32A/400V MAINSWITCH 32A/400V VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3344.01 2093.8522.00 2120 1 Q1.N SL 4.SCHALTGLIED (N-LEIT) 4. SWITCH N-CONTACT VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3344.01 2096.5024.00 2130 1 Q2 SS SCHUTZSCHALTER T-M 3P 3.5-5A PROTECT SWITCH 3P 3.5-5A VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3344.01 2096.5153.00 SL 3PH VERBINDUNGSSTECKER 3PH PLUG LINK VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3344.01 2096.5082.00 VK SCHUTZLEITERKL.2.5QMM VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3009.01 2091.9773.00 Q3 Q4 Q5 Q6 Q7 2140 1 Q2X Q3X Q4X Q5X Q6X Q7X 2150 1 X20.1 X20.2 X20.3 2400 1 X33 DX WAGO BRUECKEN-STECKER DUMMY PLUG VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3344.01 2097.5634.33 2410 1 X36 DX WAGO BRUECKEN-STECKER DUMMY PLUG VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3344.01 2097.5634.36 2420 1 X41 DX WAGO BRUECKEN-STECKER DUMMY PLUG VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: 2097.5634.41 Benennung/Designation ERSATZTEILLISTE ZR800C1 LEISTUNGSS. SPARE PART LIST FOR 2098.5009.01 ZR800C1 Datum/ Date 2009-07-09 Abt. / Dept. 7TSK Name / Name RO Sprach./Lang Ä.I. / C.I de en 04.00 Blatt/Sheet 6 of 10 Dokument Nr. / Document No. 2098.5067.01 ST Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision ## 2096.3344.01 2430 1 X42 DX WAGO BRUECKEN-STECKER DUMMY PLUG VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3344.01 2097.5634.42 2440 1 X44 DX WAGO BRUECKEN-STECKER DUMMY PLUG VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3344.01 2097.5634.44 2500 1 A35 ED VERTEILER-N-NETZ INTERFACE POWER DISTR. VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3009.01 2096.3550.02 2510 1 A36 NJ SCHALTNETZT. AC90-264V POWER SUPPLY 12V/40W VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3009.01 1081.0254.00 2610 1 W35 DX W35 NETZKAB.-HILFSSPG. W35 MAIN POWER KABLE VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3009.01 2096.3450.00 2620 1 W45 DX W45 DC-KABEL-HILFSSPG. W45 DC CABLE VAR 11 12 13 14 15 16 21 22 23 24 25 26 31 32 33 34 35 36 41 42 43 44 45 46 ## Verwendet in: ## 2096.3009.01 2096.3444.00 3000 0 0999.9610.00 3010 1 A50 EE RACK CONTROLLER RACK CONTROLLER ## Verwendet in: ## 2098.5009.01 2096.4505.02 3110 1 X53A DX CAN ABSCHL. 9POL.X53A CAN TERMINATING X53A ## Verwendet in: ## 2098.5009.01 2097.5628.00 3120 1 X53B DX CAN ABSCHL. 15POL.X53B CAN TERMINATING X53B ## Verwendet in: ## 2098.5009.01 2097.5611.00 3130 1 X53D DX CAN ABSCHL. 15POL.X53D CAN TERMINATING X53D ## Verwendet in: ## 2098.5009.01 2097.5605.00 3150 1 X54B DX BRUECKEN-ST REF.SPG.-REDUZ. A50/X7 DUMMY PLUG REDUCED_REF_B A50/X7 ## Verwendet in: ## 2098.5009.01 2097.5592.00 PB BEMERKUNG NOTE Pos.: 3010 bis 3990 Gestell - Komponenten Benennung/Designation ERSATZTEILLISTE ZR800C1 LEISTUNGSS. SPARE PART LIST FOR 2098.5009.01 ZR800C1 Datum/ Date 2009-07-09 Abt. / Dept. 7TSK Name / Name RO Sprach./Lang Ä.I. / C.I de en 04.00 Blatt/Sheet 7 of 10 Dokument Nr. / Document No. 2098.5067.01 ST _ Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation 3500 1 W48 DG PATCHKABEL 2M 1-1 BL PATCHCABEL 2M 1-1 BL ## Verwendet in: ## 2098.5009.01 3600 1 3710 1 BA VH 4055.6458.00 WW DICHTUNGSSCHAUMBAND PVC 8X6 14SH SEALING TAPE ## Verwendet in: ## 2096.2002.01 2096.2119.00 KZ FUEHLSTIFT RD2.7X17.5 GUIDE PIN VAR 11 12 13 14 21 22 23 24 31 32 33 34 41 42 43 44 51 52 53 54 61 62 63 64 ## Verwendet in: ## 2096.2231.01 0043.5727.00 3720 1 MF ANSCHLUSSHALTER CONNECTION HOLDER VAR 11 12 13 14 21 22 23 24 31 32 33 34 41 42 43 44 51 52 53 54 61 62 63 64 ## Verwendet in: ## 2096.2231.01 2096.2290.00 3800 1 MZ ABDECKUNG 2 COVER 2 VAR 11 12 13 14 15 21 22 23 24 25 31 32 33 34 35 41 42 43 44 45 51 52 53 54 55 61 62 63 64 65 ## Verwendet in: ## 2099.5019.00 2096.2925.00 3900 1 2096.2131.02 E1 ZE LUEFTERSATZ ML FAN KIT MP VAR 11 12 13 14 15 16 21 22 23 24 25 26 ## Verwendet in: ## 2096.2377.01 Sachnummer Stock No. Ersatzteil Subst.part E2 3910 1 SL LEISTUNGSTRENNSCHALTER 63A 63A MAIN POWER SWITCH VAR 51 52 53 54 55 61 62 63 64 65 ##Verwendet in: ##2096.2154.01 2096.5001.00 3920 1 SL 4.SCHALTGLIED (N-LEIT) 4. SWITCH N-CONTACT VAR 51 52 53 54 55 61 62 63 64 65 ##Verwendet in: ##2096.2154.01 2096.5018.00 3930 1 SL LEISTUNGSSCHALT.4P125A POWER SWITCH 4P 124A VAR 56 66 ##Verwendet in: ##2096.2154.01 2093.8839.00 3940 1 SS SCHUTZSCHALTER TM 2P 15A / C PROTECT SWITCH 2P 15A - C VAR 51 52 53 54 55 56 61 62 63 64 65 66 ##Verwendet in: ##2096.2154.01 2096.5224.00 3950 1 SS SCHUTZSCHALTER T-M 1P 3A - C PROTECT SWITCH 1P 3A - C VAR 51 52 53 54 55 56 61 62 63 64 65 66 ##Verwendet in: ##2096.2154.01 2096.5030.00 3960 1 SS SCHUTZSCHALTER T-M 1P 6A - C PROTECT SWITCH 1P 6A - C VAR 51 52 53 54 55 56 61 62 63 64 65 66 ##Verwendet in: ##2096.2154.01 2096.5047.00 Benennung/Designation ERSATZTEILLISTE ZR800C1 LEISTUNGSS. SPARE PART LIST FOR 2098.5009.01 ZR800C1 Datum/ Date 2009-07-09 Abt. / Dept. 7TSK Name / Name RO Sprach./Lang Ä.I. / C.I de en 04.00 Blatt/Sheet 8 of 10 Dokument Nr. / Document No. 2098.5067.01 ST _ Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH 3970 1 ED VERTEILER-N-NETZ INTERFACE POWER DISTR. VAR 51 52 53 54 55 56 61 62 63 64 65 66 ##Verwendet in: ##2096.2154.01 2096.3550.02 3980 1 DX WAGO BRUECKEN-STECKER DUMMY PLUG VAR 51 52 53 54 55 56 61 62 63 64 65 66 ##Verwendet in: ##2096.2154.01 2097.5634.33 3990 1 DX WAGO BRUECKEN-STECKER DUMMY PLUG VAR 51 52 53 54 55 56 61 62 63 64 65 66 ##Verwendet in: ##2096.2154.01 2097.5634.36 4000 1 DX WAGO BRUECKEN-STECKER DUMMY PLUG VAR 51 52 53 54 55 56 61 62 63 64 65 66 ##Verwendet in: ##2096.2154.01 2097.5634.41 4010 1 DX WAGO BRUECKEN-STECKER DUMMY PLUG VAR 51 52 53 54 55 56 61 62 63 64 65 66 ##Verwendet in: ##2096.2154.01 2097.5634.42 4020 1 DX WAGO BRUECKEN-STECKER DUMMY PLUG VAR 51 52 53 54 55 56 61 62 63 64 65 66 ##Verwendet in: ##2096.2154.01 2097.5634.44 4030 1 NJ SCHALTNETZT. AC90-264V POWER SUPPLY 12V/40W VAR 51 52 53 54 55 56 61 62 63 64 65 66 ##Verwendet in: ##2096.2154.01 1081.0254.00 4040 1 DX AC 1PH A1.VERST. KAB. W61 AC 1PH A1.AMPLIF.CAB. W61 VAR 51 52 53 54 55 56 61 62 63 64 65 66 ##Verwendet in: ##2096.2154.01 2097.4850.00 4050 1 DX AC 1PH A2.VERST. KAB. W62 AC 1PH A2.AMPLIF.CAB. W62 VAR 52 53 54 55 56 62 63 64 65 66 ##Verwendet in: ##2096.2154.01 2097.4867.00 4060 1 DX AC 1PH A3.VERST. KAB. W63 AC 1PH A3.AMPLIF.CAB. W63 VAR 53 54 55 56 63 64 65 66 ##Verwendet in: ##2096.2154.01 2097.4873.00 4070 1 DX AC 1PH A4.VERST. KAB. W64 AC 1PH A4.AMPLIF.CAB. W64 VAR 54 55 56 64 65 66 ##Verwendet in: ##2096.2154.01 2097.4880.00 4080 1 DX AC 1PH A5.VERST. KAB. W65 AC 1PH A5.AMPLIF.CAB. W65 VAR 55 56 65 66 ##Verwendet in: ##2096.2154.01 2097.4896.00 4090 1 DX AC 1PH A6.VERST. KAB. W66 AC 1PH A6.AMPLIF.CAB. W66 2097.4909.00 Benennung/Designation ERSATZTEILLISTE ZR800C1 LEISTUNGSS. SPARE PART LIST FOR 2098.5009.01 ZR800C1 Datum/ Date 2009-07-09 Abt. / Dept. 7TSK Name / Name RO Sprach./Lang Ä.I. / C.I de en 04.00 Blatt/Sheet 9 of 10 Dokument Nr. / Document No. 2098.5067.01 ST Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision VAR 56 66 ##Verwendet in: ##2096.2154.01 Benennung/Designation ERSATZTEILLISTE ZR800C1 LEISTUNGSS. SPARE PART LIST FOR 2098.5009.01 ZR800C1 Datum/ Date 2009-07-09 Abt. / Dept. 7TSK Name / Name RO Sprach./Lang Ä.I. / C.I de en 04.00 Blatt/Sheet 10 of 10 Dokument Nr. / Document No. 2098.5067.01 ST Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH ACHTUNG EGB/ATTENTION ESD *VARIANTENERKLAERUNG *EXPLANATION OF MODELS Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision VAR02=ATV-SPLIT AUSFUEHRUNG MOD02=ATV SPLIT VERSION VAR03=ATV-COMB. AUSFUEHRUNG MOD03=ATV COMBINED VERSION VAR04=DTV - AUSFUEHRUNG MOD04=DTV VERSION VAR05=DTV - AUSFUEHRUNG MIT ADE MOD05=DTV VERSION WITH ADE VAR06=DAB - AUSFUEHRUNG ML MIT SX801 MOD06=DAB VERSION MP WITH SX801 VAR24=DTV - KLEINLEISTUNG MOD24=DTV LOW POWER VAR25=DTV+ADE KLEINLEISTUNG MOD25=DTV+ADE LOW POWER 100 1 A15 ED HF-STEUERS.UMSCH. RF-EXCITER SWITCHING VAR 02 03 05 25 ## Verwendet in: ## 2099.1507.01 2095.3305.02 200 1 A15 ED RF-SWITCH RF-SWITCH VAR 04 06 24 ## Verwendet in: ## 2099.1507.01 2095.3257.02 300 1 W11B DX AF-Kabel W11-12-13B AF-Cable W11-12-13B VAR 02 03 ## Verwendet in: ## 2099.1507.01 2097.5440.00 DV RG179D BNC BU-E/BNC ST RF-CAB. 75 OHM 2000MM VAR 02 03 04 05 06 ## Verwendet in: ## 2099.1507.01 2097.5857.00 DV RG316 BNC-St/EBU 2000MM RF CABLE 50 OHM 2XBNC VAR 02 03 04 05 06 ## Verwendet in: ## 2099.1507.01 2088.3503.00 ED RACK CONTROLLER SV8000 RACK CONTROLLER SV8000 VAR 24 25 ## Verwendet in: ## 2099.1507.01 2098.9740.02 W12B W13B 400 1 W21B W22B W23B W24B W31B W32B W34B W35B W42B 500 1 W41B W43B 510 1 A100R Benennung/Designation ERSATZTEILLISTE ZR800V1 VORSTUFENS. SPARE PART LIST FOR 2099.1507.01 ZR800V1 Datum/ Date 2008-11-05 Abt. / Dept. 7TS4 Name / Name BM Sprach./Lang Ä.I. / C.I de en 03.00 Blatt/Sheet 1 of 1 Dokument Nr. / Document No. 2099.1513.01 ST Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH ACHTUNG EGB/ATTENTION ESD *VARIANTENERKLAERUNG *EXPLANATION OF MODELS VAR02=ATV-AUSFUEHRUNG FUER ML MOD02=ATV VERSION FOR MP VAR03=DTV-AUSFUEHRUNG FUER ML MOD03=DTV VERSION FOR MP VAR04=DAB-AUSFUEHRUNG FUER ML MIT SX801 MOD04=DAB VERSION FOR MP WITH SX801 VAR22=ATV-AUSFUEHRUNG FUER HL MOD22=ATV VERSION FOR HP VAR23=DTV-AUSFUEHRUNG FUER HL MOD23=DTV VERSION FOR HP VAR24=DAB-AUSFUEHRUNG FUER HL MIT SX801 MOD24=DAB VERSION FOR HP WITH SX801 Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision 100 1 W11A DX AF-KABEL W11-12-13A AF-CABLE W11-12-13A VAR 02 22 ## Verwendet in: ## 2099.1007.01 2097.5434.00 DV RG179D BNC BU-E/BNC ST RF-CAB. 75 OHM 2000MM ## Verwendet in: ## 2099.1007.01 2097.5857.00 DV RG316 BNC-St/EBU 2000MM RF CABLE 50 OHM 2XBNC ## Verwendet in: ## 2099.1007.01 2088.3503.00 W12A W13A 200 5 W21A W22A W23A W24A W31A W32A W34A W35A W42A 300 2 W41A W43A 400 1 X100A FT EINBAUADAPTER 8P.GER 2XRJ45 COUPLER JACK STRAIGHT ## Verwendet in: ## 2099.1007.01 1093.9122.00 410 1 W48 DG PATCHKABEL 2M 1-1 BL PATCHCABEL 2M 1-1 BL VAR 22 23 24 ## Verwendet in: ## 2099.1007.01 4055.6458.00 420 1 W54A DY RACK CONT.-EXC. A W54A RACK CONT.-EXC. A W54A VAR 22 23 24 ## Verwendet in: ## 2099.1007.01 2097.5392.00 430 1 W55 DY RACK CONT.-NETCCU W55 RACK CONT.-NETCCU W55 VAR 22 23 24 ## Verwendet in: ## 2099.1007.01 2097.5411.00 440 1 W56A DG PATCHKABEL CAT6. 0.5M PATCHCABLE CAT.6. 0.5M VAR 22 23 24 0041.9283.00 Benennung/Designation ERSATZTEILLI. ZR800T1 EINBAUS.SX800 SPARE PART LIST FOR 2099.1007.01 ZR800T1 Datum/ Date 2009-07-03 Abt. / Dept. 3TSS Name / Name KA Sprach./Lang Ä.I. / C.I de en 04.00 Blatt/Sheet 1 of 2 Dokument Nr. / Document No. 2099.1013.01 ST Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH ## Verwendet in: ## 2099.1007.01 X54B DX BRUECKEN-ST REF.SPG.-REDUZ. A50/X7 DUMMY PLUG REDUCED_REF_B A50/X7 VAR 22 23 24 ## Verwendet in: ## 2099.1007.01 2097.5592.00 Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision 450 1 Benennung/Designation ERSATZTEILLI. ZR800T1 EINBAUS.SX800 SPARE PART LIST FOR 2099.1007.01 ZR800T1 Datum/ Date 2009-07-03 Abt. / Dept. 3TSS Name / Name KA Sprach./Lang Ä.I. / C.I de en 04.00 Blatt/Sheet 2 of 2 Dokument Nr. / Document No. 2099.1013.01 ST Pos.-Nr. ItemNo Menge Quantity ME Unit El.Kennz Ref.Des. Benennung / Bezeichnung Designation Sachnummer Stock No. Ersatzteil Subst.part BA VH ACHTUNG EGB/ATTENTION ESD *VARIANTENERKLAERUNG *EXPLANATION OF MODELS Für diese Unterlage behalten wir uns alle Rechte vor. Ausgedruckte Dokumente unterliegen nicht dem Änderungsdienst. For this document all rights are reserved. Printed documents are not subject to revision VAR02=ZULUFT OBEN MOD02=AIR INLET TOP VAR03=ZULUFT UNTEN MOD03=AIR INLET BOTTOM VAR04=ABLUFT OBEN MOD04=AIR OUTLET TOP VAR05=ABLUFT UNTEN MOD05=AIR OUTLET BOTTOM VAR10=LUEFTERSATZ ML 210L/S 50/60HZ MOD10=FAN KIT ML 210L/S 50/60HZ VAR12=LUEFTERSATZ ML 190L/S 115V AC 50/60HZ MOD12=FAN KIT ML 190L/S 115V AC 50/60HZ 10 1 ZM TEMPERATURFUEHLER THERMOMETER PROBE VAR 04 05 ## Verwendet in: ## 2096.2377.01 2010.0006.00 20 1 ZE LUEFTERSATZ ML FAN KIT MP VAR 10 ## Verwendet in: ## 2096.2377.01 2096.2131.02 30 1 ZE LUEFTERSATZ ML FAN KIT MP VAR 12 ## Verwendet in: ## 2096.2377.01 2096.2131.12 120 1 CM 8UF 400V D40 L70 M8 MOTOR CAPACITOR VAR 02 ## Verwendet in: ## 2096.2131.01 2092.8287.00 130 1 CM 32UF 5% 400V RD45XH95 KABEL 250MM MOTOR CAPACITOR 32UF 5% 400V VAR 12 ## Verwendet in: ## 2096.2131.01 2096.2548.00 Benennung/Designation ERSATZTEILLISTE KL830M1 LUFTSATZ ML Sprach./Lang Ä.I. / C.I de en 02.00 Blatt/Sheet 1 of 1 Dokument Nr. / Document No. KL830M1 Datum/ Date 2008-08-01 Abt. / Dept. 7TSK Name / Name RO 2096.2383.01 ST
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : HUPFAUER Create Date : 2009:08:27 14:00:10+02:00 Modify Date : 2012:01:03 17:11:53-06:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2012:01:03 17:11:53-06:00 Creator Tool : FrameMaker 7.2 Format : application/pdf Title : 32 SLX8000-12.12.07-01.00.book Creator : HUPFAUER Document ID : uuid:835dee48-0147-43d9-8cee-3b9a59e85c3c Instance ID : uuid:8ac03b9c-1faa-4197-96f3-f23b4fd3ad33 Producer : Acrobat Distiller 5.0.5 (Windows) Page Count : 133EXIF Metadata provided by EXIF.tools