TransCore 76007 FHSS TRANSCEIVER MODULE User Manual M6e Transcore Developer s Guide

TransCore FHSS TRANSCEIVER MODULE M6e Transcore Developer s Guide

Users Manual

875-0034-02 Rev1Mercury®6e - Transcore Developer’s Guide
Government Limited Rights Notice: All documentation and manuals weredeveloped at private expense and no part of it was developed usingGovernment funds.The U.S. Government’s rights to use, modify, reproduce, release, perform,display, or disclose the technical data contained herein are restricted byparagraph (b)(3) of the Rights in Technical Data — Noncommercial Itemsclause (DFARS 252.227-7013(b)(3)), as amended from time-to-time. Anyreproduction of technical data or portions thereof marked with this legend mustalso reporduce the markings. Any person, other than the U.S. Government, whohas been provided access to such data must promptly notify ThingMagic, Inc.ThingMagic, Mercury, Reads Any Tag, and the ThingMagic logo are trademarksor registered trademarks of ThingMagic, Inc. Other product names mentioned herein may be trademarks or registeredtrademarks of ThingMagic, Inc. or other companies.© Copyright 2000–2009 ThingMagic, Inc. All Rights ReservedThingMagic, Inc.One Broadway, 5th floorCambridge, MA 02142866-833-4069Revision 1August, 2009
 3 ContentsIntroduction to the Mercury6e-Transcore Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Microcontroller 14RFID ASIC 14Connectors 14M6e-TC Digital Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Firmware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Boot Loader. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Application Firmware  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Verifying Application FW Image CRC 16Functionality of the Embedded Modules  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Regional Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Frequency Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18Frequency Units  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Frequency Hop Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Frequency Hop Interval. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19RF Power Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Power Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Power Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20TX Read Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20TX Write Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Power Amplifier Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21Antenna Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21Monostatic Mode  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Power Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Power Modes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4Tag Buffer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22Flash Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24Accessing the Flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Upgrading Application FW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Serial and USB Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Installing the USB Driver  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Windows 26General Purpose Inputs/Outputs (GPIO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28Overview of the Communication Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29Host-to-Reader Communication  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29Reader-to-Host Communication  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31CCITT CRC-16 Calculation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Format for Microprocessor Reply to Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Microprocessor ACK Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Microprocessor Fault Reply Message. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Microprocessor Data Reply Message. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Command Set  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37Boot Loader Commands  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38Flash Read Sector (02h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Get Boot Loader/Firmware Version (03h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Responses 40Returned Hardware Version Table 40Boot Firmware (04h). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Set Baud Rate (06h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Erase Flash Sector (07h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Verify Image CRC (08h). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Start Bootloader (09h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Get Current Program (0Ch). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Write Flash Sector (0Dh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Loading an Application Image 44Get Sector Size (0Eh)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Modify Flash Sector (0Fh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Multi-Protocol Tag Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47Get Tag Buffer (29h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Get Tags Remaining 47
5Get Tag EPCs 48Get Tag EPCs and Metadata 50Clear Tag Buffer (2Ah) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Multi-Protocol Tag Read (2Fh)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Allegro/Title-21 Tag Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57Command Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Read Tag ID Single (21h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Write Request (24h; A003h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61Title-21 ACK Request (24h; C000h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62General ACK Request (24h; F00Fh)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64Title-21 Read Request (28h; 8000h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Read Request (28h; C003h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Random Number Request (28h; D001h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68TDMA Read Request (28h; E003h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70Jump to Reset Request (2Ch; D203h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71eGo/SeGo Tag Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Command Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Group Select Options 74Read Tag ID Single (21h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76Read Tag ID Multiple (22h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77Standard Syntax 77Minimal Syntax 79Write Tag Data (24h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Lock Tag Data (25h). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Read Tag Data (28h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85Custom Tag Operations (2Dh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88ATA Tag Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91Command Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Read Tag ID Single (21h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93Read Tag ID Multiple (22h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94Gen2 Tag Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95Tag Singulation/Select Functionality. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Select Algorithm and Parameters 96Select Process 97Flag Persistence Rules 98Operations supporting Tag Singulation/Select 99Read Tag Single (21h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101Get Tag EPC 101Get Tag EPC and Meta Data 102Read Tag Multiple (22h). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
6Basic Tag Inventory 107Tag Inventory with Select 109Tag Inventory With Embedded Operations 110Write Tag EPC (23h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112Write Tag Data (24h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113Lock Tag (25h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116Kill Tag (26h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117Read Tag Data (28h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118Get Tag Data 120Get Tag Data and Meta Data 120Get Tag Buffer (29h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Clear Tag Buffer (2Ah) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Gen2 Tag Specific (2Dh). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Alien Higgs Silicon (Chip Type=0x01) 123NXP Silicon (Chip Type=0x02) 127Erase Block Tag Specific (2Eh). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132Get Configuration Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133Get Hardware Version (10h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134Get Antenna Configuration (61h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135Get Read TX Power (62h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136Get Current Tag Protocol (63h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136Get Write TX Power (64h). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138Get Frequency Hop Table (65h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138Get User GPIO Inputs (66h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139Get Current Region (67h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139Get Power Mode (68h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140Get User Mode (69h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141Get Reader Configuration(6Ah)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142Get Protocol Configuration (6Bh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142Get Reader Statistics (6Ch)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143Get Available Protocols (70h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146Get Available Regions (71h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146Get Current Temperature (72h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147Set Configuration Commands  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148Set Antenna Port (91h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149Set Read TX Power (92h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149Set Current Tag Protocol (93h). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Set Write TX Power (94h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Set Frequency Hop Table (95h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Set User GPIO Outputs (96h). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
7Set Current Region (97h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152Set Power Mode (98h). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153Set User Mode (99h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153Set Reader Configuration(9Ah) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153Set Protocol Configuration (9Bh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154Set Gen2 Session 155Set Q Value 156FCC Test Commands  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157Set Operating Frequency (C1h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158Transmit CW Signal (C3h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158Get Operating Frequency (C8h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159Appendix A: Hardware Details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  161Mechanicals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161Antenna Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162Communications Connector  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163Connectors 163Appendix B: Using the ArbSer Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  165Reading a Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166Get Version Command 167Boot Firmware Command 168Set Current Region Command 170Set Current Tag Protocol Command 171Set Read TX Power Command 171Set Antenna Port Command 171Unexpected Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174Serial Communication Does Not Work 174Commands Return a Non-Zero Status Code 174No Tag ID is Returned 175Appendix C: Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  177Common Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177FAULT_MSG_WRONG_NUMBER_OF_DATA – (100h). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177Cause 177Solution 178FAULT_INVALID_OPCODE – (101h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178Cause 178Solution 178FAULT_UNIMPLEMENTED_OPCODE – 102h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
8Cause 178Solution 178FAULT_MSG_POWER_TOO_HIGH – 103h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178Cause 178Solution 179FAULT_MSG_INVALID_FREQ_RECEIVED (104h)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179Cause 179Solution 179FAULT_MSG_INVALID_PARAMETER_VALUE - (105h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179Cause 179Solution 179FAULT_MSG_POWER_TOO_LOW - (106h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179Cause 179Solution 180FAULT_UNIMPLEMENTED_FEATURE - (109h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180Cause 180Solution 180FAULT_INVALID_BAUD_RATE - (10Ah) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180Cause 180Solution 180Bootloader Faults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181FAULT_BL_INVALID_IMAGE_CRC – 200h  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181Cause 181Solution 181FAULT_BL_INVALID_APP_END_ADDR – 201h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181Cause 181Solution 181FPGA Faults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182FAULT_PROGRAM_ERASE_FAILED – 2E0h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182Cause 182Solution 182FAULT_PROGRAM_FAILED – 2E1h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182Cause 182Solution 182FAULT_PROGRAM_VERIFY_FAILED – 2E2h  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183Cause 183Solution 183FAULT_PROGRAM_OPERATION_FAILED – 2E3h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183Cause 183Solution 183
9FAULT_PROGRAM_NOT_LOADED – 2E4h  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183Cause 183Solution 183Flash Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184FAULT_FLASH_BAD_ERASE_PASSWORD – 300h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184Cause 184Solution 184FAULT_FLASH_BAD_WRITE_PASSWORD – 301h  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184Cause 184Solution 185FAULT_FLASH_UNDEFINED_ERROR – 302h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185Cause 185Solution 185FAULT_FLASH_ILLEGAL_SECTOR – 303h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185Cause 185Solution 185FAULT_FLASH_WRITE_TO_NON_ERASED_AREA – 304h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185Cause 185Solution 185FAULT_FLASH_WRITE_TO_ILLEGAL_SECTOR – 305h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186Cause 186Solution 186FAULT_FLASH_VERIFY_FAILED – 306h  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186Cause 186Solution 186Protocol Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187FAULT_NO_TAGS_FOUND – (400h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .188Cause 188Solution 188FAULT_NO_PROTOCOL_DEFINED – 401h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188Cause 188Solution 188FAULT_INVALID_PROTOCOL_SPECIFIED – 402h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188Cause 188Solution 189FAULT_WRITE_PASSED_LOCK_FAILED – 403h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189Cause 189Solution 189FAULT_PROTOCOL_NO_DATA_READ – 404h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189Cause 189
10Solution 189FAULT_AFE_NOT_ON – 405h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189Cause 189Solution 189FAULT_PROTOCOL_WRITE_FAILED – 406h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190Cause 190Solution 190FAULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407h  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190Cause 190Solution 190FAULT_PROTOCOL_INVALID_WRITE_DATA – 408h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190Cause 190Solution 190FAULT_PROTOCOL_INVALID_ADDRESS – 409h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190Cause 190Solution 191FAULT_GENERAL_TAG_ERROR – 40Ah  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191Cause 191Solution 191FAULT_DATA_TOO_LARGE – 40Bh  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191Cause 191Solution 191FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191Cause 191Solution 191FAULT_PROTOCOL_KILL_FAILED - 40Eh. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192Cause 192Solution 192FAULT_PROTOCOL_BIT_DECODING_FAILED - 40Fh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192Cause 192Solution 192FAULT_PROTOCOL_INVALID_EPC – 410h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192Cause 192Solution 192FAULT_PROTOCOL_INVALID_NUM_DATA – 411h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192Cause 192Solution 193FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193FAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC - 423h. . . . . . . . . . . . . . . . . . . . . . . . 193FAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193FAULT_GEN2 PROTOCOL_INSUFFICIENT_POWER - 42Bh. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
11FAULT_GEN2 PROTOCOL_NON_SPECIFIC_ERROR - 42Fh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193FAULT_GEN2 PROTOCOL_UNKNOWN_ERROR - 430h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193Analog Hardware Abstraction Layer Faults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194FAULT_AHAL_INVALID_FREQ – 500h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194Cause 194Solution 194FAULT_AHAL_INVALID_FREQ – 501h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194Cause 194Solution 194FAULT_AHAL_TRANSMITTER_ON – 502h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194Cause 194Solution 194FAULT_ANTENNA_NOT_CONNECTED – 503h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195Cause 195Solution 195FAULT_TEMPERATURE_EXCEED_LIMITS – 504h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195Cause 195Solution 195FAULT_LOW_RETURN_LOSS – 505h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195Cause 195Solution 195Tag ID Buffer Faults  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196FAULT_TAG_ID_BUFFER_NOT_ENOUGH_TAGS_AVAILABLE – 600h . . . . . . . . . . . . . . . . . . . . . . 196Cause 196Solution 196FAULT_TAG_ID_BUFFER_FULL – 601h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196Cause 196Solution 196FAULT_TAG_ID_BUFFER_REPEATED_TAG_ID – 602h  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197Cause 197Solution 197FAULT_TAG_ID_BUFFER_NUM_TAG_TOO_LARGE – 603h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197Cause 197Solution 197System Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198FAULT_SYSTEM_UNKNOWN_ERROR – 7F00h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198Cause 198Solution 198FAULT_TM_ASSERT_FAILED – 7F01h. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198Cause 198
12Solution 198Appendix D: FPGA Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  199Creating an FPGA Image DAT File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199Loading an FPGA Image. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203
Introduction to the Mercury6e-Transcore Module  13 Introduction to the Mercury6e-Transcore ModuleThe ThingMagic® Mercury®6e embedded module is an RFID engine that you can integrate with other systems to create RFID-enabled products which support the custom Transcore tag protocols: eGo, SeGo, ATA and Allegro/Title-21. The Arbser utility provides an easy to use command line interface to configure the reader, read from and write tags, and demonstrate the modules capabilities. ArbSer can issue the Command Set that is detailed in this document in thier hex format. For information about the ArbSer application, see Appendix B: Using the ArbSer Application.This document is for developers and explains how to incorporate the Mercury6e-Transcore (M6e-TC) into a third-party host system. Hardware OverviewThe M6e-TC module is based on the Mercury5e (M5e) embedded module, designed to be incorporated into products requiring powerful RFID capabilities in a small form factor. The following table shows the basic features of the M6e-TC hardware:
Hardware Overview14 Introduction to the Mercury6e-Transcore ModuleFeatures of the M6e-TC HardwareThe M6e-TC is a single board module designed for more space-constrained applications. The digital and analog electronics are on the same circuit board. MicrocontrollerThe M6e-TC uses the Atmel ARM7 microcontroller with 256 kB of on-chip flash memory for storage of all calibration and program data.RFID ASICAll base-band analog circuitry and PLL circuitry are contained within the Impinj R2000 RFID ASIC with ThingMagic front end for improved sensitivity.ConnectorsThe M6e-TC supports one MMCX connectors for a single monostatic antenna.Item M6e-TCProcessor Atmel AT91SAM7SE-256Flash memory 256 kBOn-chip RAM 32 kBRF Architecture ASIC Intel R2000 with ThingMagic front end for improved sensitivityInput Power Requirements +5VDC Communication Interfaces •  High-speed serial interface•  USB with auto-detectProtocols supported eGo, SeGo, ATA, Allegro/Title-21, Gen2Dimensions: (L x D x H) 78 x 63 x 8 mmRegions supported NA, OPEN
Firmware OverviewIntroduction to the Mercury6e-Transcore Module 15M6e-TC Digital ConnectorsThe digital connector provides power, serial communications signals, and access to the GPIO inputs and outputs. The communications interface for the M6e-TC is a 14-pin digital connector. This connector provides power, serial communications signals, including USB support, and access to the GPIO inputs and outputs. See the following table: Pin-out of 14-pin Digital Communications ConnectorFirmware OverviewThe software (SW) for the M6e-TC consists of two separate programs that coexist in flash memory:  The boot loader, which is started at power on, is not field upgradable. It is programmed into flash when the module is manufactured.Pin # Signal1GND2GND3GND4+5V5+5V6 USB_+5V (Input to M6e-TC)7 Digital Output 18 Digital Output 29 Digital Input 110 Digital Input 211 RS-232 RX TTL from host12 RS-232 TX TTL to host13 USB_DM14 USB_DP
Firmware Overview16 Introduction to the Mercury6e-Transcore Module The application firmware, which implements the actual reader functionality, is field upgradable.Boot Loader The boot loader provides low-level functionality. This program provides a customer interface for upgrading the application firmware and storing data into flash. When a module is powered up or reset, the boot loader code is automatically copied from sector 0 of flash into the Microprocessor’s on-chip RAM, and executed. The boot loader provides the following features: Ability to read / write / erase flash memory Upgrade application FW Change serial baud rate Verify image CRCApplication Firmware The application firmware (FW) is an important software component of the module. It contains the protocol code as well as all the user interfaces to set and get various system parameters. The application FW is started using the Boot Firmware command in the boot loader; it does not start by itself upon power up.NoteYou can use the Arbser utility to upgrade the reader firmware.Verifying Application FW Image CRCThe application FW has an image level Cyclic Redundancy Check (CRC) embedded in it to protect against corrupted firmware during an upgrade process. (If the upgrade is unsuccessful, the CRC will not match the contents in flash.) When the boot loader starts the application FW, it first verifies that the image CRC is correct. If this check fails, then the boot loader does not start the application FW.The upgrade process uses a series of individual 250-byte packet write operations to ensure that an upgrade is successfully completed for the complete image. It also ensures that the application FW in flash was not corrupted accidently, and can be expected to perform properly when executed.
Functionality of the Embedded Modules  17 Functionality of the Embedded ModulesThis section highlights some of the functionality of the modules. The details for using the serial commands to control this functionality are found in Overview of the Communication Protocol.Regional Support The modules have differing levels of support for operation and use under the laws and guidelines of several regions. NoteA region must be set before the module will perform any RF operations.The regional support is shown in the following table.Supported RegionsThe regional functionality is set using a single serial command, Set Configuration Commands. Setting the Region configures the regional default settings including: Loads the Frequency Hop Table with the appropriate table for the selected region. Sets the PLL frequency to the first entry in the hop table, even if the RF is off. Selects the transmit filter, if applicable.NoteThe Open Region allows the module to be manually configured within the full capabilities supported by the hardware. No regulatory limits, including: frequency range, channel spacing and transmit power limits, are enforced. The Open Region should be used with caution.Region Regulatory Support M6e-TCNorth America (NA) FCC 47 CFG Ch. 1 Part 15Industrie Canada RSS-210 YesOpen Region No regulatory compliance enforced Yes
Frequency Setting18 Functionality of the Embedded ModulesFrequency SettingThe modules have a PLL synthesizer that sets the modulation frequency to the desired value. Whenever the frequency is changed, the module must first power off the modulation, change the frequency, and then turn on the modulation again. Since this can take several milliseconds, it is possible that tags are powered off during a frequency hop. In addition to setting the default regional settings, the modules have commands that allow the transmit frequency to be set manually. Frequency UnitsAll frequencies in the Mercury embedded products are expressed in kHz using unsigned 32-bit integers. For instance, a carrier frequency of 915 MHz is expressed as 915000 kHz. The PLL is set automatically to the closest frequency - based on the minimum frequency quantization for the current region - that matches the specified value. The Mercury embedded modules have an absolute minimum quantization of 50 kHz. Each region also has a minimum quantization based on regulatory specifications, which may be greater. The following table details the frequency quantization in kHz for each region setting. Regional Frequency QuantizationWhen manually setting frequencies the module will round down for any value that is not an even multiple of the supported frequency quantization. CAUTION!!!Use these commands with extreme caution.It is possible to change the module’s com-pliance with the regional regulations.Region Frequency Quantization Minimum Frequency Maximum FrequencyNA 250 kHz 902,000 kHz 928,000 kHzOpen 50 kHz 860,000 kHz 930,000 kHz
Frequency SettingFunctionality of the Embedded Modules 19For example: In the NA region, setting a frequency of 902,999 kHz results in a setting of 902,750 kHz.When setting the frequency of the module, any frequencies outside of the valid range for the specified region are rejected. Frequency Hop TableThe frequency hop table determines the frequencies used by the modules when transmitting. The hop table characteristics are: Contains up to 62 slots.  Valid frequencies for the region currently selected. Changes not stored in flash, thus changes made are not retained after a power cycle or a restart of the boot loader.  Inability to change individual entries after uploading without reloading the entire table.  Frequencies used in the order of entries in the table.If necessary for a region, the hop table can be randomized to create a pseudo-random sequence of frequencies to use. This is done automatically using the default hop tables provided for each region.Frequency Hop IntervalWhen hopping frequencies the period of time the module will stay on an individual frequency is defined by the Hop Interval. This value is based on the region’s regulatory requirements and indicates the maximum time the reader will stay on a frequency which maybe lower than that allowed by the regulatory requirements.The supported regions and their maximum hop interval is defined in the following table:Maximum Frequency Hop IntervalRegion Max Hop IntervalNA 200 msOpen 400 ms
RF Power Setting20 Functionality of the Embedded ModulesRF Power SettingThe power setting is calibrated at the factory and parameters are stored in flash memory to ensure the power output is within +/– 1 dB of the desired setting. The power limits are set by both hardware limitations and enforced by the firmware. Power UnitsAll power values are reported in centi-dBm. Therefore, a power setting of 2500 corresponds to 25 dBm. All power values in the serial interface are specified as signed 16-bit integers. A dBm means power referenced to 1mW. Therefore, the conversion from watts to dBm is:dBm = 10 log10(power in mW)For example: 0.1W = 100mW = 20dBm and 1W = 1000mW = 30dBm.Power Calibration A power calibration event occurs when the Power set point is changed, the Frequency is changed, or the RF field is turned on. The power calibration routine calibrates the power within 10 ms. NotePower calibration only occurs once when the RF power is turned on. It does not occur periodically when the RF field is on. This is not an issue during normal operation,= since a frequency hop occurs within the regulatory hop interval (see Maximum Frequency Hop Interval for region specific values) and thermal drift does not affect the power level significantly. However, in CW waveform mode (Transmit CW Signal), no power calibration occurs unless the power or frequency is changed. Thus, it is possible to experience thermal drift in this usage if the unit is left to transmit continuously for a significant period of time.TX Read PowerThe TX read power is used for all non-write commands to tags. This may include, but is not limited to, commands to read a tag ID and read tag data.
Power Amplifier ProtectionFunctionality of the Embedded Modules 21TX Write PowerThe TX write power is used only during commands that change a tag’s state. This includes commands for Lock, Kill, as well as Tag ID Write and Tag Data Write. NoteDuring Write commands, which both write to and verify the written contents, the entire operation will be done at the Tx Write Power, including tag singulation and the write verify.Power Amplifier ProtectionCertain usage scenarios can cause the M6e-TC to operate into very low return loss situations and/or cause a considerable amount of reflected power to feed back into the M6e-TC power amplifier (PA). Under such conditions damage to the M6e-TC power amplifier has been observed due to this reflected power. To avoid damage to the PA in such cases the software protection will shut the transmitter down when these conditions are detected and the module will return the fault code 0x0505- FAULT_LOW_RETURN_LOSS – 505h - for the response status code.The PA protection feature is on by default. It can be turned off using the Set Reader Configuration(9Ah) command. WARNING!ThingMagic does not recommend turning off PA protection under any circumstance. Turning off PA protection greately increases the possibility of hardware damage. Module operation with PA protection off is at the users own risk. Antenna PortsMonostatic ModeThe M6e-TC has one antenna port which both transmits and receives. To set up the module to use a single antenna in monostatic mode, connect the antenna to port 1 (labeled J1 on Printed Circuit Board) which is responsible for both TX and RX communication.
Power Management22 Functionality of the Embedded ModulesPower ManagementThe modules use different methods and levels of power management.Power ModesThe M6e-TC was designed for power efficiency and offers several different power management modes, set using Set Power Mode (98h). The following lists the current modes being offered: Full Power Mode – In this mode, the unit operates at full power to attain the best performance possible. This mode is only intended for use in cases where power consumption is not an issue. This is the default Power Mode at startup. Minimal Saving Mode – This automatically executes basic power savings that do not severely degrade system performance May result in a nominal 1 ms additional delay. Medium Saving Mode – This mode may add up to 50 ms of delay between commands. It performs more aggressive power savings, such as automatically shutting down the analog section between serial commands, and then restarting it whenever a tag command is issued.  Maximum Saving Mode – This mode essentially shuts down the digital and analog boards, except to power the bare minimum logic required to wake the processor. It can take up to 150 ms to wake the processor and execute the desired command.Note:  In Maximum Saving Mode the USB interface is disabled and the RS232 interface communication speed is limited to 9600 baud.Tag BufferThe Tag buffer stores tags, and their metadata, found using the Read Tag Multiple command. The size of the tag buffer for each module is defined in the following table:
Tag BufferFunctionality of the Embedded Modules 23Tag Buffer SizeEach tag entry consists of a fixed number of bytes. The size depends on the value set for the Max EPC Length parameter in Set Reader Configuration(9Ah). Each entry consists of the following fields:Tag Buffer EntryIn addition to the tag EPC data each entry contains meta data about how, where and when the tag was read. When using the Get Tag Buffer (29h) command you can choose to get the following tag meta data returned with each tag extracted from the tag buffer:M6e-TCTag Buffer Size in Tag ID entries 190Total Entry Size Field Size Description18 bytes (Max EPC Length = 96bits)EPC Length 2 bytes Indicates the actual EPC length of the tag read. Cannot exceed the Max EPC length setting.PC Word 2 bytes Contains the Protocol Control bits for the tag.EPC 12 bytes Contains the tag’s EPC value padded with trailing zeros if the size is less than the Max EPC Length size.Tag CRC 2 bytes The tag’s CRC.68 bytes (Max EPC Length = 496bits)EPC Length 2 bytes Indicates the actual EPC length of the tag read. Cannot exceed the Max EPC length setting. Varies by Protocol:•  Gen2 = PCWord + EPC ID + CRC•  Other = EPC ID + CRCPC Word 2 bytes Contains the Protocol Control bits for the tag.EPC 62 bytes Contains the tag’s EPC value padded with trailing zeros if the size is less than the Max EPC Length size.Tag CRC 2 bytes The tag’s CRC.
Flash Memory24 Functionality of the Embedded ModulesTag Read Meta DataWhenever a Tag entry is placed in the buffer, it uses up a single entry with the EPC section containing the maximum EPC length number of bits, regardless of the actual EPC size of the tag read. The extra bits in the entry are padded with trailing zeros.After the Multi-Protocol Tag Read command finishes, it places all of the found tags into the Tag buffer, and then returns the number of tags found to the user. Only unique tags read on each antenna are added to the Tag buffer; none of the entries show repeated Tag EPCs. Repeated reads on an antenna will cause the Read Count field to be incremented for that tag entry. Multiple Get Tag Buffer commands must be sent to read out the Tags. The Tag buffer acts as a First In First Out (FIFO) — the first Tag found by the reader is the first one to be read out. See Get Tag Buffer (29h).The Tag buffer is reset only when the Clear Tag Buffer command is sent. See Clear Tag Buffer (2Ah). This allows multiple Multi-Protocol Tag Read commands to be used to acquire one consistent tag buffer set. Flash MemoryThe M6e-TC has on-board flash memory. This flash is divided into four different sectors of varying sizes. Table 4 shows the memory map for the M6e-TC. Only sector 0x03 is set aside for user data and the other sectors are used by the application FW. The flash sector utilities simplify the interface providing a means to develop interfaces that work across these platforms. Meta Data Field DescriptionAntenna ID The antenna on with the tag was read.Read Count The number of times the tag was read on [Antenna ID]. Timestamp The time the tag was read, relative to the time the command to read was issued, in milliseconds. If the Tag Read Meta Data is not retrieved from the Tag Buffer between read commands there will be no way to distinguish order of tags read with dif-ferent read command invocations. Frequency The frequency on which the tag was readRFU Reserved for Future Use - ThingMagic OnlyLQI/RSSI The receive signal strength of the tag response.Protocol ID The tag’s Protocol ID as defined by the Tag Protocol IDs table
Flash MemoryFunctionality of the Embedded Modules 25Flash Memory Sector MappingAccessing the FlashThe flash is accessed only through the boot loader program. Flash is not accessible while the application FW is running.All accesses to flash are in terms of two-byte word addresses and word lengths. Thus, the Write Flash Sector, Read Flash Sector, Erase Flash Sector, and Modify Flash Sector commands all use the same argument types. The maximum amount of flash that can be written or modified at a single time is 125 words, and the maximum amount of flash that can be read at a single time is 124 words. This is a limitation of the serial interface and data packet sizes. Multiple data packets are used to read/write/modify a larger area of flash.When using the Erase Flash Sector or Write Flash Sector commands, the correct password must be provided to complete the operation. This is done to protect against accidentally erasing or writing to the flash. See Boot Loader Commands.Upgrading Application FWThe application FW is upgraded in flash. New versions of firmware are released in a .sim binary file format . The .sim binary file format is a compressed file format that stores the data in raw binary.Sector Access Code M6e-TC Start AddressM6e-TC Size (bytes)Erase Password Write PasswordBootLoader Read Only 0x01 0x000000 16 kB na naApplication Read/Write 0x02 0x00C000 208 kB 0x08959121 0x02254410User Memory Read/Write 0x03 0x008000 16 kB 0x79138766 0x76346700Hardware InfoApplication Data (RAM)Read Only 0x04 0x0040000x20000016 kB32 kBna na
Serial and USB Interfaces26 Functionality of the Embedded ModulesSerial and USB InterfacesThe M6e-TC module can communicate to a host processor via the TTL logic level RS-232 serial protocol or via Universal Serial Bus (USB) protocol, both accessed on the 14-pin M6e-TC Digital Connectors.The module does not need to be software configured to operate on one or the other interface, just send data over the interface to use it. However, the following considerations should be made when using one or both interfaces: Once a command is initiated on one interface, the entire synchronous operation (full command and response) must be completed on that interface. Upon completion of an operation a new command can be sent on either interface. If both interfaces are to be used the user is responsible for maintaining order of execution. If commands are sent on both interfaces simultaneously execution order cannot be guaranteed. When setting the baud rate via Set Baud Rate (06h) this changes the communication speed on the RS232 Interface only, whether set using the RS232 interface or USB. The USB speed is not changed. USB communication speed is dictated by the USB protocol and has a maximum bitrate of 12Mbps. When configuring Power Modes, using Maximum Saving Mode (0x03) will shut off the USB interface. If Set Power Mode (98h) is called using the USB interface and mode 0x03 is specified the module will instead be set to Medium Saving Mode (0x02). In order to set the module to mode 0x03 the command must be called using the RS232 interface. Power consumption will increase when the USB interface is connected. A level converter is necessary to interface to other devices that use standard 12V RS-232.  Only three pins are required for RS232 communication (TX, RX, and GND). Hardware handshaking is not supported.  The interfaces use an interrupt-driven FIFO that empties into a circular buffer.  The developer is responsible for ensuring that the host processor’s RS232 receiver has the capability to receive up to 256 bytes of data at a time without overflowing.Installing the USB DriverWindowsWhen connecting to the M6e-TC through the USB interface from a Windows PC a few installation steps are required for Windows to recognize the M6e-TC and properly
General Purpose Inputs/Outputs (GPIO)Functionality of the Embedded Modules 27configure the communications protocol. In order to use the USB interface with Windows you must have the m6etc.inf file. The installation steps are:1.    Plug in the USB cable to the M6e-TC (devkit) and PC.2.    Windows should report “Found New Hardware - M6e-TC Serial” and open the Hardware Installation Wizard.3.    Select the Install from a list or specific location (Advanced) option, click Next.4.    Select Don’t search..., click Next, then Next again.5.    Click Have Disk and navigate to where the m6etc.inf file is stored; select it, click Open, then OK.6.    “Mercury6eTC” should now be shown under the Model list. Select it and click Next then Finished. NoteThe M6e-TC driver file has not been Microsoft certified so compatibility warnings will be displayed. These can be ignored and clicked through.7.    A COM port should now be assigned to the M6e-TC. If you aren’t sure what COM port is assigned you can find it using the Windows Device Manager:a.    Open the Device Manager (located in Control Panel | System).b.    Select the Hardware tab and click Device Manager.c.    Select View | Devices by Type | Ports (COM & LPT)The device appears as Mercury6eTC (COM#). General Purpose Inputs/Outputs (GPIO)The M6e-TC modules has four TTL level signals, two 3.3/5V serial input sensor ports (GPIO inputs) and two output indicator ports (GPIO outputs) of up to 24 mA, available on the 14-pin digital connector. These can be controlled via the Get User GPIO Inputs and Set User GPIO Outputs commands.For further information, see Get User GPIO Inputs (66h) and Set User GPIO Outputs (96h).
Default Settings28 Functionality of the Embedded ModulesDefault Settings Since default settings may change across release and be different across platforms we recommend using the Get Configuration Commands to obtain default settings.None of the configurable settings in the application FW are saved in non-volatile memory. Thus the system will always boot up in the same default state, regardless of how it was previously configured.
Overview of the Communication Protocol  29 Overview of the Communication ProtocolThe serial communication between a computer (host) and the reader is based on a synchronized command-response/master-slave mechanism. Whenever the host sends a message to the reader, it cannot send another message until after it receives a response. The reader never initiates a communication session; only the host initiates a communication session. This protocol allows for each command to have its own timeout because some commands require more time to execute than others. The host manages retries, if necessary. The host keeps track of the state of the intended reader if it reissues a command.Host-to-Reader CommunicationHost-to-reader communication is packetized according to the following diagram. The reader can only accept one command at a time, and commands are executed serially, so the host waits for a reader-to-host response before issuing another host-to-reader command packet. Header Data Length Command Data CRC-16 ChecksumHdr Len Cmd CRC Hi CRC LOI1 byte 1 byte 1 byte 0 to N bytes 2 bytes
Host-to-Reader Communication30 Overview of the Communication ProtocolThe fields are summarized in the following table.:Field Length DescriptionHeader (Hdr) 1 byte Defines the start of the packet. Equal to 0xFF1Data Length (Len)1.Minimum packet length is 5 bytes; the maximum packet length is 255 bytes.1 byte Defines the length, N, of the data field contained in the packet.Command 1 byte Specifies the command that the reader is to execute.Data N bytes(0 to 250) Defines the binary data required by the reader for use with a command. This could, for example, represent transponder data to be written. The length, N, can vary between 0 and 250 bytes.CRC-16 Checksum (CRC HI, CRC LO) 2 bytes CRC-16 checksum (high order byte first). CRC polynomial is CCITT CRC-16, with a preload of 0xFFFF. This does not fully specify the operation of the CRC, see CCITT CRC-16 Cal-culation.
Reader-to-Host CommunicationOverview of the Communication Protocol 31Reader-to-Host CommunicationThe following diagram defines the format of the generic Response Packet sent from the reader to the host. The Response Packet is different in format from the Request Packet.The fields are summarized in the following table.:Field Length DescriptionHeader (Hdr) 1 byte Defines the start of the packet. Equal to 0xFF1Data Length (Len) 1 byte Defines the length, M, of the data field contained in the packet. Length can be 0 – 248 bytes2Command 1 byte OpCode of the last command received3Status Word 2 bytes Specifies the status of the last command, Successful = 0x0000, else it contains a fault code.Data M bytes(0 to 248) Defines the binary data returned by the reader in response to a command. This could, for example, represent data read from a transponder. Data length, M, can be a minimum of 0 and a maximum of 248 bytes.CRC-16 Checksum (CRC HI, CRC LO) 2 bytes CRC-16 checksum (high order byte first). CRC polynomial is CCITT CRC-16, with a preload of 0xFFFF. This does not fully specify the operation of the CRC, see CCITT CRC-16 Calcu-lation.Header Data Length Command Data CRC-16 ChecksumHdr Len Cmd CRC HI CRC LO1 byte 1 byte 1 byte 2 bytesStatus WordStatus Word0 to M bytes2 bytes
Reader-to-Host Communication32 Overview of the Communication ProtocolCCITT CRC-16 CalculationThe same CRC calculation is performed on all serial communications between the host and the reader. The CRC is calculated on the Data Length, Command, Status Word, and Data bytes. The header (SOH, 0xFF) is not included in the CRC.A sample implementation of the CCITT CRC-16 algorithm is shown in this section. The CRC_calcCrc8() function is written to calculate the CRC one byte at a time, with the calculated value stored in crc_calc. The crc_calc value must be pre-loaded the first time the CRC_calcCrc8() function is called with 0xFFFF to initialize the calculated CRC. The final value of crc_calc is sent as the 16-bit CRC at the end of the message. 1.The minimum packet length is 7 bytes and the maximum packet length is 255 bytes.2.Each host command receives a response from the reader. In the response packet, the Header, Data Length, Command, Data, andChecksum are functionally similar to the command packet.3.The only difference is the addition of the Status Word field. The Status Word has two types of values. A Status Word value of 0(Zero) means the command received was successful. Any other value represents a fault.
Reader-to-Host CommunicationOverview of the Communication Protocol 33An example implementation of CRC calculation, taken from the Arbser source CrcUtils.c, is shown here:/** @fn void CRC_calcCrc8(u16 *crcReg, u16 poly, u16 u8Data)* @ Standard CRC calculation on an 8-bit piece of data.  To make it* CCITT-16, use poly=0x1021 and an initial crcReg=0xFFFF.* *  Note:  This function allows one to call it repeatedly to continue* calculating a CRC.  Thus, the first time it's called, it* should have an initial crcReg of 0xFFFF, after which it* can be called with its own result.** @param *crcRegPointer to current CRC register.* @param poly Polynomial to apply.* @param u8Datau8 data to perform CRC on.* @return None.*/void CRC_calcCrc8(u16 *crcReg, u16 poly, u16 u8Data){u16 i;u16 xorFlag;u16 bit;u16 dcdBitMask = 0x80;for(i=0; i<8; i++){// Get the carry bit.  This determines if the polynomial should be// xor'd with the CRC register.xorFlag = *crcReg & 0x8000;// Shift the bits over by one.*crcReg <<= 1;// Shift in the next bit in the data bytebit = ((u8Data & dcdBitMask) == dcdBitMask);*crcReg |= bit;// XOR the polynomialif(xorFlag){*crcReg = *crcReg ^ poly;}// Shift over the dcd maskdcdBitMask >>= 1;}}
Format for Microprocessor Reply to Host34 Overview of the Communication ProtocolFormat for Microprocessor Reply to HostThere are three different types of replies that the microprocessor can make to the host as follows:  Acknowledge that the command was properly processed (ACK) Return a fault code Provide data that is requested by the hostThis section describes each of these three types. Unless otherwise specified, all commands return, as part of the Reply message, a status word with an ACK or a Fault. Those commands that return a Data Reply message are clearly shown.Microprocessor ACK MessageMany of the commands require the microprocessor to perform a function, but do not require the microprocessor to send data back to the host. However, since the host cannot send a message until the microprocessor replies, an ACK is sent.The ACK message contains no data. It returns the same OpCode that was sent originally to the microprocessor, sets the Status Word to 0x0000 (zero) and the Data Length to 0x00 (zero).
Format for Microprocessor Reply to HostOverview of the Communication Protocol 35The following shows an example of an ACK message to an Erase Flash command.The value in the OpCode field (0x07) is the same as the Erase Flash OpCode, 0x07.Microprocessor Fault Reply MessageIf a problem occurs during the execution of a command, the microprocessor returns a non-zero status value. Although this usually implies a fault or error, sometimes the non-zero status simply indicates a condition of the system. For instance, when executing a Read Tag Single command, if no tags are found, a status code of 0x0400 is returned. An example of a fault reply message is shown for the Erase Flash command.A list of error codes is included in Appendix C: Error Messages. Refer to this list when encountering any non-zero status codes.Microprocessor Data Reply MessageIf the requested command requires that the microprocessor returns data, then the microprocessor creates a message similar to the Microprocessor ACK Message with the data length set to a non-zero value. Since this command does not require a data field, the length field is set to Zero.FF 00 07 00 00 F4 27SOH Length OpCode Status CRCFF 00 07 02 00 F6 27SOH Length OpCode Status CRCFF 00 07 00 00 F4 27SOH Length OpCode Status CRC
Format for Microprocessor Reply to Host36 Overview of the Communication ProtocolHere is an example of a Reply message with Data Field Length not zero. This message happens to be a successful reply to Read Tag Single command.FF 0A 21 00 00 C8 05 07 A8 00 84 C4 FF 9E E0 F7 25SOH Length OpCode Status Tag ID Tag CRC CRC
Command Set 37Command SetThe following list defines the OpCodes that are used in the embedded modules firmware. As these products grow, more OpCodes will be added to enhance the functionality of the product. The timeout for the commands are in milliseconds. The maximum value for any user-configurable timeout is 65,535msec (0xFFFF), unless otherwise noted. The OpCodes are divided into five main categories: 0x00 – 0x1F: Boot Loader Commands 0x20 – 0x5F: Application Tag Commands - Depending on the current protocol setting will correspond to:–  Multi-Protocol Tag Commands–  Allegro/Title-21 Tag Commands–  eGo/SeGo Tag Command Set–  ATA Tag Command Set–  Gen2 Tag Commands 0x60 – 0x8F: Get Configuration Commands 0x90 – 0xBF: Set Configuration Commands 0xC0 – 0xCF: FCC Test Commands
Boot Loader Commands38 Command SetBoot Loader CommandsThe BootLoader is automatically started upon power up, and allows access to the on-board flash memory along with other commands. The program exits only when the Boot Firmware command is received. Once that occurs, the firmware image starts executing and sends back a reply to the Boot Firmware command. The BootLoader can also be started using command 0x09, Start BootLoader. The following table shows which commands are supported by the Boot loader and in some cases the application.Boot Loader CommandsOpCode Command Name Arguments Return BL App0x02 Flash Read Sector (02h) Address, Sector, bytes  Data Y N0x03 Get Boot Loader/Firmware Version (03h)none Acknowledge Y N0x04 Boot Firmware (04h) none Acknowledge Y N0x06 Set Baud Rate (06h) Baud Rate Acknowledge Y Y0x07 Erase Flash Sector (07h) Sector Number, password Ack Y N0x08 Verify Image CRC (08h) none Acknowledge Y N0x09 Start Bootloader (09h) none Acknowledge N Y0x0C Get Current Program (0Ch) none 1 Byte indicating program currently runningYY0x0D Write Flash Sector (0Dh) Sector enum, memory offset, length, data to writenone Y N0x0E Get Sector Size (0Eh) Sector enum Size of sector in bytes YN0x0F Modify Flash Sector (0Fh) Sector enum, memory offset, length to read Data in flash Y N
Boot Loader CommandsCommand Set 39Flash Read Sector (02h)The Flash Read Sector command reads the contents of flash from the specified sector and offset address. Since the length of the Microprocessor reply packet is limited to 248 bytes, reading the application firmware data requires multiple read commands. NoteLength is defined as the number of 16-bit words, and the maximum value of length is 124 words. In this example, the sector number 02 indicates the application area. This command reads the first five data elements of the application, which is equivalent to the original command (using data length of 05). The sector codes can be found in Flash Memory Sector Mapping..The reply to this command looks like thisGet Boot Loader/Firmware Version (03h)The Get Boot Loader command returns the Boot Loader, Hardware, and Application version numbers. The Boot Loader, Hardware, and Application FW version numbers are stored in flash. The Boot Loader and Hardware version numbers are each 32-bit numbers. The application has a 96-bit version code. The command to retrieve firmware version is shown in the following table.FF 06 02 00 00 00 00 02 05 FA 59SOH Length OpCode Start Address Sector Num Bytes To Read CRCFF 0A 02 00 00 01 23 45 67 89 AB CD EF 01 23 BC EDSOH Length OpCode Status 1Word 11.Word 1 contains the data located at address 0x208000.2Word 22.Word 2 contains the data at address 0x208001, and so forth. (Remember that the Microprocessor data is word addressed.)Word 3 Word 4 Word 5 CRCFF 00 03 1D 0CSOH Length OpCode CRC
Boot Loader Commands40 Command SetResponsesA sample response for the M6e-TC is as follows:The following information is embedded in the reply to the command: The boot loader version is 07.09.17.00. This number is in hex format. HW Version is 01000001. For a definition, see Returned HW Versions. The application firmware was compiled on 2007-October-12. The application firmware version is 09.05.12.00. This number is in hex format. The protocol supported by this firmware – Gen2 and ISO 18000-6C. Returned Hardware Version TableThe following table provides a definition of each HW version returned by the Get Boot Loader/Firmware Version command.Returned HW VersionsIf the Get Boot Loader/Firmware Version command returns a different value than those listed in the table, you should contact support@thingmagic.com.Boot Firmware (04h)The Boot Firmware command tells the boot loader to run the current firmware image stored in flash in the following sequence:1.    If flash is locked application firmware is run.FF 14 03 00 00 07 09 17 00 01 00 00 01 20 07 10 12 09 05 12 00SOHLength OpCode Status BootLoader Ver Hardware Ver Firmware Date Firmware Version00 00 00 10 6B CCSupported Protocols CRCModule Defined Version DescriptionM6e-TC HW_VERID_1_0W 0x10000001 A0 and B0 prototypes
Boot Loader CommandsCommand Set 411.    If flash is not locked: the application firmware image CRC verified and flash is locked before it is run. 2.    If the image is invalid, a fault code is returned to the host. 3.    If the application firmware is started successfully, it sends the response to the Boot Firmware command. The response is identical to the response to a Get Version command, except that the OpCode is 0x04 instead of 0x03. NoteThe Application Firmware boot up time takes approximately 600ms the first time it is run after a new firmware installation. Subsequent boot up times will be approximately 50ms. Set Baud Rate (06h)The Set Baud Rate command has a default baud rate of 9600 bps. Since the code method of specifying the baud rate is processor dependent, a new interface was created to make the modules easily interchangeable. The following table shows the hexadecimal equivalent for each baud rate:FF 00 04 1D 0BSOH Length OpCode CRC
Boot Loader Commands42 Command SetIn the following example, the baud rate is specified as a 32-bit value. This example sets the baud rate to 115200:The response to baud rate change is sent at the baud rate that the Set Baud Rate command was transmitted. Once the baud rate has changed, the new rate is in effect until the baud rate is changed by power cycling the reader. The baud always reverts to 9600 after a power cycle.NoteSet baud rate has no effect on the USB interface speed, only the RS232 interface, whether executed from the RS232 interface or USB.Baud Rate (decimal) Baud Rate (hex)9600 0x0000258019200 0x00004B0038400 0x0000960057600 0x0000E100115200 0x0001C200230400 0x00038400460800 0x00070800921600 0x000E1000FF 04 06 00 01 C2 00 FD 30SOH Length OpCode Baud Rate CRC
Boot Loader CommandsCommand Set 43Erase Flash Sector (07h)The Erase Flash Sector command erases the sector specified by the sector number. as defined by Flash Memory Sector Mapping.The following example shows the command to erase sector 2 of the flash.Verify Image CRC (08h)After uploading a new application firmware image, the application CRC can be checked with the Verify Image CRC command. The application CRC is already embedded in the firmware image, so this command calculates the firmware’s CRC in flash and compares it to the pre-stored value. It returns a fault code if the application firmware fails the CRC checks. A failed CRC means that the application cannot run, and needs to be downloaded again.The boot loader runs this command automatically before loading the application the first time it is l run. If the CRC check fails, the boot loader does not run the application to prevent corrupted code from executing on the Microprocessor. Subsequent invocations will not verify the CRC since the flash is locked.Start Bootloader (09h)The Start Bootloader command shuts off the analog board and starts the boot loader while inside the application. This is necessary to perform an upgrade of the firmware while the system is running.FF 05 07 08 95 91 21 02 7F 91SOH Length OpCode Password Sector CRCFF 00 08 1D 07SOH Length OpCode CRCFF 00 09 1D 06SOH Length OpCode CRC
Boot Loader Commands44 Command SetGet Current Program (0Ch)The Get Current Program command returns a code for the current program being executed in the module. These codes are defined as follows:To get the current program command, send the following to the module:The module responds as follows, indicating that it is the application program:Write Flash Sector (0Dh) The Write Flash Sector command is used to write data to the flash memory. Before writing to flash it is imperative that the flash be erased first. Attempting to write to flash before it is erased will generate an error. Alternatively the Modify Flash Sector (0Fh) command can be used.Loading an Application ImageA series of write flash commands is used to load a new application program image into flash. The Write Flassh Sector command verifies the CRC of the received data but does not verify the CRC of the complete application image. Use the Verify Image CRC (08h) command to verify the application once it is uploaded. The start address is a 32-bit sector offset address. It is a word address, that is different from the byte address used for instruction memory. The application code must be loaded Code Program0x21 M6e-TC Bootloader0x22 M6e-TC ApplicationFF 00 0C 1D 0CSOH Length OpCode CRCFF 01 0C 00 00 22 ?? ??SOH Length OpCode Status Program CRC
Boot Loader CommandsCommand Set 45starting from word address 0x00000000. Since the flash is a 16-bit device, there must be an even number of data bytes. The number of data bytes to be written is embedded in the length of the payload (N) by the formula:LengthDataToWriteInWords = (N – 8) / 2The password required for each sector is defined in Flash Memory Sector Mapping.The following example shows a Write Flash Sector command writing to the Application Sector, starting at the beginningNoteDO NOT send a packet that spans two sectors. Split the packet into 2 separate messages, then send the first message to sector “x” and the second to sector “x+1”.Get Sector Size (0Eh) The size of a flash sector can be retrieved from the module using the Get Sector Size command. Since different products may have different flash sector sizes, this command is useful for ensuring that the module has enough memory to store the desired data. This example receives the sector size for the application area:The response to this command is shown in the following example:The size of the sector is returned in bytes. Sector 2 (application) is 212992 bytes.Modify Flash Sector (0Fh)The Modify Flash Sector command is used as a read-modify-write operation in the flash. Since the Modify Flash Sector command erases the flash sector each time it is FF 0F 0D 02 25 44 10 00 00 00 00 02 12 34 56 78 90 12 73 4CSOH Length OpCode Password Start Address Sector Data To Write CRCFF 01 OE 02 D1 BFSOH Length OpCode Sector CRCFF 04 OE 00 00 00 03 40 00 88 54SOH Length OpCode Status Size of Sector CRC
Boot Loader Commands46 Command Setcalled, it could prematurely wear out the flash if it is used too often. This command should only be used to modify a few variables (that is less than one serial packet’s worth) at a time.This command works only for the User area. FF 0F 0F 79 13 87 66 00 00 00 00 03 12 34 56 78 90 12 4C FASOH Length OpCode Password Start Address Sector Data To Write CRC
Multi-Protocol Tag Commands47Multi-Protocol Tag CommandsThe application commands are used to interact with RFID tags in the field. These commands can have slightly different behavior based upon the current protocol selected in the system. Applications Commands Get Tag Buffer (29h)After a Multi-Protocol Tag Read command is executed, the found tags are stored in an internal Tag Buffer. The Get Tag Buffer command can perform several different operations depending on the syntax used. These operations are: Get tags remaining in the tag buffer Get tag EPCs  Get tag EPCs and their Tag Read Meta Data.Get Tags RemainingTo determine the number of tags remaining in the buffer, send the Get Tag Buffer command with a data length of zero:This command returns the current read index, the location of the next tag to be read, and the current write index, the location where the next tag will be written. These two numbers can be used to get the number of tags left in the tag buffer: OpCode Command Name0x29 Get Tag Buffer (29h)0x2A Clear Tag Buffer (2Ah)0x2F Multi-Protocol Tag Read (2Fh)FF 00 29 1D 26SOH Length OpCode CRC
Multi-Protocol Tag Commands48Tags Left = WriteIndex - ReadIndexThe following response shows there are three tags left in the buffer, and the first one has already been read (the read index parameter starts counting from 0.):Get Tag EPCsWhen you want to get the tag EPCs out of the buffer and don’t care about the tag read metadata, the options available with this syntax maybe useful. This syntax reads out the requested number of tags from the buffer. A maximum of 13 tags are read at a time, less if Max EPC Length is set to 496 bits. Multiple Get Tag Buffer commands may be required to obtain the complete results from a single Multi-Protocol Tag Read command. If more tags are requested than remain in the buffer an error will be returned.All tag buffer indexes are encoded as 16-bit unsigned integers. The indexes start counting from 0. Thus, a start index of 0 indicates tag #1, and a start index of 10 would indicate tag #11.There are two ways to read tag EPCs out of the buffer when you only want EPC values. The first way is to send a Get Tag Buffer command with the desired number of tags, n. This retrieves the next n tags, starting from the current read index. In the previous example, the read index was 1, indicating that one tag was already read. To read the next two tags, set the number of tags parameters to 2. This returns tags number 2 and 3 in the tag buffer:When using the Get Tag Buffer command in this way, the read index is automatically incremented internally. Thus, if the read index was ‘1’ before getting two tags, then it is incremented to ‘3’ at the end of this command. Another way to get the second and third tags is to explicitly send the start and end indexes of the tags to read. This is used to retrieve any contiguous block of tag buffer entries at any time.FF 04 29 00 00 00   01 00   04 87 72SOH Length OpCode Status ReadIndex WriteIndex CRCFF 02 29 00 02 57 EBSOH Length OpCode # Tag IDs to Return CRC
Multi-Protocol Tag Commands49Using the start and end index method does not affect the read index that is internally stored in the module. The above request returns a message with two tags. The length of each tag EPC record returned is defined based on the max EPC length configured with Set Reader Configuration(9Ah), regardless of the size of a specific tag’s EPC. The sizes and fields of the EPC portion of a tag buffer entry is defined in the Tag Buffer Entry table.For example: A 64-bit tag has the length set to 0x60 (16-bit PC + 64-bit tag EPC + 16-bit tag CRC), but only the first 12 bytes of the tag record is filled in, the trailing bytes, after the CRC are padded with zeros.  An 96-bit GEN2 tag, the length is 0x80 (16-bit PC (Protocol Control) word + 96-bit tag EPC + 16-bit tag EPC CRC). In the response below, two tag EPCs are returned. Tag #1 is a 96-bit EPC tag and tag #2 is a 64-bit EPC tag.NoteUsing this syntax the number of tags in the response is not specified. It must be determined by the message length.FF 04 29 00   01 00   03 CC 94SOH Length OpCode Start Idx End Idx CRCFF 24 29 00 00SOH Length OpCode Status00 80 30 00 11 11 22 22 33 33 44 44 55 55 66 66 18 35EPC Length PC Word Tag EPC Tag CRC00 60 20 00 11 11 22 22 33 33 44 44 C2 41 00 00 00 00EPC Length PC Word Tag EPC Tag CRC PaddingD3 32CRC
Multi-Protocol Tag Commands50Get Tag EPCs and MetadataUsing this syntax for getting information from the tag buffer provides several benefits: When at tag EPC is returned there is no padding if the actual tag EPC is shorter than the configured max EPC length. This helps minimize the amount of data returned. Any or all fields of the Tag Read Meta Data can be returned. In the event of a communication error the last Get EPC and Metadata request can be repeated.When data is requested using this syntax the response will contain as many tags as can be fit in the response packet. The response will indicate how many tags were returned and should be processed accordingly.This version of Get Tag Buffer takes two additional fields: the Metadata Flags which defines what metadata will be returned and the Read Options which specifies special read functionality. The following table lists the supported values for these fields.Get EPC and Metadata Request FieldsField Value DescriptionMetadata Flags (to specify more than one OR the values together)0x0000 When no flags are set no meta data will be returned, only the tag EPC (including PC bits and tag CRC)0x0001 When bit 0 is set the Read Count will be returned0x0002 When bit 1 is set the LQI/RSSI will be returned0x0004 When bit 2 is set the Antenna ID will be returned0x0008 When bit 3 is set the Frequency will be returned0x0010 When bit 4 is set the Timestamp will be returned0x0020 RFU (ThingMagic Only)0x0040 When bit 6 is set the Protocol ID, as defined by the Tag Protocol IDs table, will be returned
Multi-Protocol Tag Commands51Read Option 0x00 Read the next set of tags from the Tag Buffer0x01 Re-send the last set of tags. Note:  When setting this option the tags will be resent starting at the same ReadIndex as the last command. If the metadata requested is different than the last request the number of tags returned might be different. To get those ‘missing’ tags, additional Get Tag Buffer commands should be sent without the re-send option, otherwise it will reset the ReadIndex again.Field Value Description
Multi-Protocol Tag Commands52ExamplesAn example command requesting Read Count, AntennaID and Timestamp Metadata Flags = 0x0001 OR 0x0004 OR 0x0010 = 0x0015 is as follows: A response contains the following information:Get EPC and Metadata Response FieldsFF 03 29 00 15 00 97 55SOH Length OpCode Metadata Flags Read Options CRCField Length ValueSOH 1 byte 0xFFLength 1 byte Based on data returnedOpCode 1 byte 0x29Metadata Flags 2 bytes Metadata contained in responseRead Options 1 byte As sent in requestTag Count 1 byte Number of tags in responseRead Count 1 byte Tag EPC/Antenna Read CountRSSI11 byte Return Signal Strength IndicatorAntenna ID11 byte Antenna ID, 4 MSBs for TX and 4 LSBs for RXFrequency13 bytes Frequency in kHzTimestamp14 bytes RTC Timestamp
Multi-Protocol Tag Commands53Here is an example response to the example request specified above. The response contains two tags as specified in the Tag Count field each with its EPC info and requested tag read metadata: Read Count, AntennaID and Timestamp:RFU12 bytes Reserved for Future Use - ThingMagic OnlyProtocol ID 1 byte Protocol ID of tag readEPC Length 2 bytes Number of bits in EPC including PC and CRC bitsPC Word 2 bytes Tag EPC Protocol Control bitsEPC ID N bytes Tag EPC.Tag CRC 2 bytes Tag EPC CRCRepeat fields starting at Read Count for remaining tags in message as defined by Tag CountCRC 2 bytes Message CRC1 - Conditionally returned depending on the Metadata Fields specified in the request.FF 34 29 00 00 00 15  00  02SOH Length OpCode Status Metadata Flags Read Options Tag Count22 11 02 50 CE F6 00 80 31 C1 11 11 22 22 33 33 44 44 55 55 66 66 FB 15Read Count Ant ID Timestamp EPC Length PC Word Tag EPC Tag CRCOE 11 04 1D 3D 3C 00 80 30 00 05 00 00 00 00 00 00 00 00 00 23 54 4A C8Read Count Ant ID Timestamp EPC Length PC Word Tag EPC Tag CRC1A B8CRCField Length Value
Multi-Protocol Tag Commands54Clear Tag Buffer (2Ah)The Clear Tag Buffer command resets the tag buffer. This clears the buffer of any current tags and reset the read index to 0. A Multi-Protocol Tag Read or Read Tag Multiple command must be issued to load new tags into the buffer.If Clear Tag Buffer or Get Tag Buffer is not used after a Multi-Protocol Tag Read to remove all tags, old tags will be left in the buffer. This means that if tags that have not been removed from the buffer are read again they will not be added to the buffer as second time, only their Read Count will be incremented.Multi-Protocol Tag Read (2Fh)The Multi-Protocol Tag Read command allows tag reading and inventorying commands to be performed on tags with different protocols at the same time, using a single command. This command contains the following request fields:Multi-Protocol Tag Read Request FieldsFF 00 2A 1D 25SOH Length OpCode CRCField Value DescriptionTM OpCode 0x2F TM OpCode indicating a multi-protocol opera-tion.Timeout [2 bytes] Indicates how long the entire command should spend attempting the operation, in mil-liseconds. When TM Option=0x00 the time gets divided equally across each protocol specified.TM Options •  0x00 = Basic Multi-protocol search. Uses Protocol Bitmask Indicates the operation to perform and addi-tional fields that will be required.Command Opcode •  0x00 - reserved•  0x21 - tag read single•  0x22 - tag read multipleIndicates the command that will be performed for each protocol specified.Note:  Allegro/Title-21 is not supported with tag read multiple.Note:  Allegro/Title-21 uses Read Request (28h; C003h) for tag read single.
Multi-Protocol Tag Commands55Search Flags [2 bytes - bitwise setting]Bit 0 = Enable end on tags foundNote:  Least Significant Bit = bit 0Indicates search options. When bit is set = 1 the option will be enabled. •  Bit 0 = 1 (0x01) the search will stop after the first tag is found, after completing that protocols entire timeout. i.e. if 4 protocols are specified with a 100ms timeout and a tag is found during searching on the second protocol the remaining protocols will not be searched and the command will return after 50ms.Bit 0 = 0 all protocols will be searched, using entire timeout.TM Option = 0x00 Fields - The following field is only used when TM Option = 0x00Protocol Bitmask Enables [4 bytes - bitwise setting]bit 0-3 = not usedbit 4 (0x00000010) = Gen2bit 5-25 = not usedbit 26 (0x04000000) = eGobit 27 (0x08000000) = SeGobit 28 (0x10000000) = ATAbit 29 (0x20000000) = Allegro/Title-21Note:  Least Significant Bit = bit 0Indicates the protocols to operate on. If the protocols bit is set to ‘1’ tags of that protocol will be included in the operation.OR values together for final settingField Value Description
Multi-Protocol Tag Commands56ExamplesTM Option = 0x00 RequestResponseNote:  If a multi-protocol Tag Read Single (command code 0x21) search results in zero tags found it will not be reported. Only successful searches are reported.FF ?? 2F ?? ?? 00 ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Timeout TM Options Cmd Opcode Search Flags Protocol Bitmask EnablesCRCFF ?? 2F ?? ?? 00 ?? ?? ??SOHLength OpCodeStatus TM Option Cmd Opcode Search Flags?? ?? ?? ?? ?? ....Protocol Id1 Protocol Response LengthProtocol Response Data(Includes Status word)?? ?? ?? ?? ?? ....Protocol Id2 Protocol Response LengthProtocol Response Data(Includes Status word)?? ??CRC
Allegro/Title-21 Tag Commands57Allegro/Title-21 Tag CommandsThe Allego/Title-21 tag commands are used to operate on Allegro/Title-21 tags and perform operations specific to those tags. These commands can only be used when the Tag Protocol of the reader is set to Allegro/Title-21 (0x001E) using Set Current Tag Protocol (93h). These commands cannot be run when in Bootloader mode, only in Application mode.Allegro/Title-21 Tag Commands TM OpCode Operation Type Allegro/Title-21 Command Transaction Type Code0x21 Read ID Single Read Tag ID Single (21h) n/a0x24 Modify Write Request (24h; A003h) 0xA003Title-21 ACK Request (24h; C000h) 0xC000General ACK Request (24h; F00Fh) 0xF00F0x28 Read Title-21 Read Request (28h; 8000h) 0x8000Read Request (28h; C003h) 0xC003Random Number Request (28h; D001h) 0xD001TDMA Read Request (28h; E003h) 0xE0030x2C Reset Jump to Reset Request (2Ch; D203h) 0xD203
Allegro/Title-21 Tag Commands58Command SyntaxAll Allegro/Title-21 tag commands, except Read Tag ID Single, follow the same standard syntax. The commands are grouped into three ThingMagic M6e-TC OpCodes, as defined in the Allegro/Title-21 Tag Commands table, indicating their general operation type. In addition to the 1 of 3 OpCodes each command will have the following fields:Standard Request FieldsThe remaining fields for each command are as defined by Transcore based on the Transaction Type Code. They occur in the same order and require the same values as described in the [Transcore doc reference].Field Value DescriptionTM OpCode 0x24 TM OpCodeTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM Options 0x00 Reserved for Future Use. Transaction Type Code [2 bytes] Allegro/Title-21 code indicating operation to per-form.
Allegro/Title-21 Tag Commands59Read Tag ID Single (21h)The Read Tag ID Single/Tag Detect command performs a search operation and returns the first Allegro/Title-21 tag it finds. Read Tag ID Single Request FieldsExamplesAn example, without TM Options, command:Field Value DescriptionTM OpCode 0x21 TM OpCodeTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM OptionsNote:  This and following fields are optional.Bit 4(LSB=bit 0))•  0 - Metadata flags must not be passed and Meta Data will not be returned. •  1 - Metadata flags must be passed and the corresponding Metadata shall be returned with the tag EPC. Metadata Flags (to specify more than one OR the val-ues together)0x0000 When no flags are set no meta data will be returned, only the tag EPC.0x0001 When bit 0 is set the Read Count will be returned0x0002 When bit 1 is set the LQI/RSSI will be returned0x0004 When bit 2 is set the Antenna ID will be returned0x0008 When bit 3 is set the Frequency will be returned0x0010 When bit 4 is set the Timestamp will be returned0x0020 When bit 5 is set the RFU (ThingMagic Only) will be returned0x0040 When bit 6 is set the Protocol is returned.FF 02 21 00 FA D6 1BSOH Length OpCode Time-out (ms) CRC
Allegro/Title-21 Tag Commands60ACK ResponseNACK ResponseNo ResponseFF 04 21 00 00 ?? ?? ?? ?? ?? ??SOH Length OpCode Status Tag ID CRCFF 00 21 ?? ?? ?? ??SOH Length OpCode Status CRCFF 00 21 04 00 B4 83SOH Length TM OpCode Status CRC
Allegro/Title-21 Tag Commands61Write Request (24h; A003h)The Write Request command writes data to the specified area of the specified tag. A non-acknowledge (NACK) error response shall be returned if an invalid password was included in the request. This command contains the following request fields:Write Request FieldsExamplesAn example command requesting ? be written to tag ? with a User Password = 0x? is:Field Value DescriptionTM OpCode 0x24 TM OpCode for tag modification operationsTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM Options 0x00 Reserved for Future Use. Transaction Type Code 0xA003 Allegro/Title-21 code indicating operation to per-form.Options [1 byte] Command specific optionsPage Number [2 bytes] Indicates which page of the tag is to be written to.Tag ID [4 bytes] Optional, based on value of Options parameter. Indicates the ID of the tag to operate on.User Password/ Global Password [4/8 bytes] Optional, based on the value of the Options param-eter. The password to operation on the tag, if required.Page Data Byte Count [1 byte] Indicates the number of data bytes to follow.Page Data Bytes [N bytes] Data to write to the tag.FF 0E + N24 ?? ?? 00 A0 03 ?? ?? ??SOH Length TM OpCode Timeout (ms) TM Option Transaction Type Code Option Page Number?? ?? ?? ?? ?? ?? ?? ?? ?? NN NN ?? ??Tag ID User/Global Password Page Data CountPage Data CRC
Allegro/Title-21 Tag Commands62ACK ResponseNACK ResponseNo ResponseTitle-21 ACK Request (24h; C000h)The Title-21 ACK Request command informs the tag that the reader has successfully received the tag ID. This will result in the tag not responding to any message whose transaction type is identical to the most recently received message for a specified period of 10 seconds, as defined in Title 21 release 1. This command contains the following request fields:FF 0C + (N+1) 24 00 00 00 A0 03 ?? ?? ?? ?? ?? ?? ?? ??  NN NN ?? ??SOH Length TM OpCode Status TM Option Transaction Type Code Options Tag ID Page Number Page Data Count (if requested)Page Data CRCFF 0B 24 04 0A 00 A0 03 ?? ?????????? ??SOH Length TM OpCode Status TM Option Transaction Type Code Options Tag ID CRCFF 00 24 04 00 E4 26SOH Length TM OpCode Status CRC
Allegro/Title-21 Tag Commands63Title-21 ACK Request FieldsExamplesAn example command requesting an ACK from tag XXX from reader XXX is:ACK ResponseNACK ResponseField Value DescriptionTM OpCode 0x24 TM OpCode for tag modification operationsTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM Options 0x00 Reserved for Future Use. Transaction Type Code 0xC000 Allegro/Title-21 code indicating operation to per-form.Tag ID [4 bytes] Indicates the ID of the tag to operate on.Reader ID [4 bytes] The reader number for the reader that is acknowl-edging the receipt of the message.Transaction Status Code [2 bytes] Code indicating the status of the transaction. FF 0D 24 ?? ?? 00 C0 00 ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Time-out (ms) TM Option Transaction Type Code Tag ID Reader ID Transaction Status Code CRCFF 03 24 ?? ?? 00 C0 00 ?? ??SOH Length TM OpCode Status TM Option Transaction Type Code CRCFF 0B 24 ?? ?? 00 C0 00 ?? ?? ?? ?? ?? ?? ??SOH Length TM OpCode Status TM Option Transaction Type Code Options Tag ID CRC
Allegro/Title-21 Tag Commands64No ResponseGeneral ACK Request (24h; F00Fh)The General ACK Request, or Sign Off Request, command informs the tag that it should not respond to any commands from the reader for the specified time period. This command contains the following request fields:General ACK Request FieldsFF 00 24 04 00 E4 26SOH Length TM OpCode Status CRCField Value DescriptionTM OpCode 0x24 TM OpCode for tag modification operationsTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM Options 0x00 Reserved for Future Use. Transaction Type Code 0xF00F Allegro/Title-21 code indicating operation to per-form.Options [1 byte] Command specific optionsTag ID [4 bytes] Indicates the ID of the tag to operate on.Time Out [1 byte] Indicates the amount of time the tag shall ignore commands from the reader, in seconds from 0-127.Condition Code Bits [1 byte] Represents a condition applicable to a tolling envi-ronment.LCD Message Page Pointer [1 byte] Tag memory page where the LCD message to be displayed is stored in ASCII. Valid range = 0x02 - 0x0F.
Allegro/Title-21 Tag Commands65ExamplesAn example command requesting an ACK from tag XXX from reader XXX is:ACK ResponseNACK ResponseNo ResponseTitle-21 Read Request (28h; 8000h)The Title-21 Read Request command reads the Title-21 tag ID from the tag. This command contains the following request fields:FF 0C 24 ?? ?? 00 F0 0F ?? ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Timeout (ms) TM Option Transaction Type Code Option Tag ID Time Out ConditionCode LCD Page PtrCRCFF 03 24 ?? ?? 00 F0 0F ?? ??SOH Length TM OpCode Status TM Option Transaction Type Code CRCFF 0A 24 ?? ?? 00 F0 0F ?? ?????????? ??SOH Length TM OpCode Status TM Option Transaction Type Code Options Tag ID CRCFF 00 24 04 00 E4 26SOH Length TM OpCode Status CRC
Allegro/Title-21 Tag Commands66Title-21 Read Request FieldsExamplesAn example command requesting an ACK from tag XXX from reader XXX is:ACK ResponseNACK ResponseNo ResponseField Value DescriptionTM OpCode 0x28 TM OpCode for Read operationsTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM Options 0x00 Reserved for Future Use. Transaction Type Code 0x8000 Allegro/Title-21 code indicating operation to per-form.Agency Code [2 byte] Agency operating the reader installation.FF 04 28 ?? ?? 00 80 00 ?? ?? ?? ??SOH Length OpCode Time-out (ms) TM Option Transaction Type Code Agency Code CRCFF 0A 28 00 00 00 80 00 ?? ?? ?? ?? ?? ??SOH Length TM OpCode Status TM Option Transaction Type Code Tag ID CRCFF 0B 28 ?? ?? 00 80 00 ?? ??SOH Length TM OpCode Status TM Option Transaction Type Code CRCFF 00 28 04 00 25 AASOH Length TM OpCode Status CRC
Allegro/Title-21 Tag Commands67Read Request (28h; C003h)The Read Request command reads data from the specified area of the specified tag. This command contains the following request fields:Read Request FieldsExamplesAn example command format is:Field Value DescriptionTM OpCode 0x28 TM OpCode for tag modification operationsTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM Options 0x00 Reserved for Future Use. Transaction Type Code 0xC003 Allegro/Title-21 code indicating operation to per-form.Options [1 byte] Command specific options. •  Determines whether the AntiPlayBack/BIST data will be included in the response.Start Page Number [2 bytes] Indicates which page of the tag is to be read.Page Count [1 byte] Number of pages to read.Tag ID [4 bytes] Optional, based on value of Options parameter. Indicates the ID of the tag to operate on. User Password/ Global Password [4/8 bytes] Optional, based on the value of the Options param-eter. The password to operation on the tag, if required.FF 0C 28 ?? ?? 00 C0 03 ?? ?? ?? ??  ?? ?? ?? ?? ?? ??SOH Length TM OpCode Timeout (ms) TM Option Transaction Type Code Option Page Number Page Count Tag ID CRC
Allegro/Title-21 Tag Commands68ACK ResponseNACK ResponseNo ResponseRandom Number Request (28h; D001h)The Random Number Request command requests a 32-bit random number from the specified tag which is used in the P/W authentication scheme. This command also specifies which page is to be read or written to with the encrypted P/W on the next cycle. This command contains the following request fields:FF ?? + N28 00 00 00 C0 03 ?? ?? ?? ?? ?? ?? ?? ?? .. .. ??  NN NN ?? ??SOH Length TM OpCode Status TM Option Transaction Type Code Options Tag ID Page Number AntiPlay-Back (0, 1, 2) [Based on Options]Page Count Page Data CRCFF 0B 28 04 0A 00 C0 03 ?? ?? ?? ?? ?? ?? ??SOH Length TM OpCode Status TM Option Transaction Type Code Options Tag ID CRCFF 00 28 04 00 25 AASOH Length TM OpCode Status CRC
Allegro/Title-21 Tag Commands69Random Number Request FieldsExamplesAn example command:ACK ResponseNACK ResponseField Value DescriptionTM OpCode 0x28 TM OpCode for tag modification operationsTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM Options 0x00 Reserved for Future Use. Transaction Type Code 0xD001 Allegro/Title-21 code indicating operation to per-form.Options [1 byte] Command specific optionsTag ID [4 bytes] Indicates the ID of the tag to operate on. Page Number [2 bytes] Species which page is to be operated on in the next transaction.Next Command [2 bytes] Specifies which command the reader will be send-ing ot the tag on the next transaction, by Transac-tion Type Code. Only Read and Write Request commands are supported.FF 0C 28 ?? ?? 00 D0 01 ?? ?????????? ?? ?? ?? ?? ??SOH Length TM OpCode Timeout (ms) TM Option Transaction Type Code Option Tag ID Page Number Next Com-mand CRCFF ?? + N28 00 00 00 D0 01 ?? ?? ?? ?? ?? ?? ?? ??SOH Length TM OpCode Status TM Option Transaction Type Code Random Number ATA Page NumberCRCFF 0B 28 04 0A 00 D0 01 ?? ?? ?? ?? ?? ?? ??SOH Length TM OpCode Status TM Option Transaction Type Code Options Tag ID CRC
Allegro/Title-21 Tag Commands70No ResponseTDMA Read Request (28h; E003h)The TDMA Read Request command returns the tag ID from the first tag to respond only. This command contains the following request fields:TDMA Read Request FieldsExamplesAn example command is:ACK ResponseFF 00 28 04 00 25 AASOH Length TM OpCode Status CRCField Value DescriptionTM OpCode 0x28 TM OpCode for tag modification operationsTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM Options 0x00 Reserved for Future Use. Transaction Type Code 0xE003 Allegro/Title-21 code indicating operation to per-form.Options [1 byte] Command specific optionsNumber of Slots [1 byte] Specifies how many slots are available for the tags to choose from. Valid values from 0x01-0xFFFF ?? 28 ?? ?? 00 E0 03 ?? ?? ?? ??SOH Length TM OpCode Timeout (ms) TM Option Transaction Type Code Option Number of Slots CRCFF 0B 28 00 00 00 E0 03 ?? ?? ?? ?? ?? ?? ??SOH Length TM OpCode Status TM Option Transaction Type Code Option Tag ID CRC
Allegro/Title-21 Tag Commands71NACK ResponseNo ResponseJump to Reset Request (2Ch; D203h)The Jump to Reset Request command requests the tag perform a hard reset.  The reset will occur the same as a hardware reset and the decision is made by the tag to perform a cold boot or a warm boot by analyzing the first 32 bits of page 0000 in the tag. If the bits are all 0s or all 1s, then a cold boot will be performed, otherwise a warm boot will occur. This command contains the following request fields:Jump to Reset Request FieldsExamplesAn example command is:FF 0B 28 04 0A 00 E0 03 ?? ?? ?? ?? ?? ?? ??SOH Length TM OpCode Status TM Option Transaction Type Code Options Tag ID CRCFF 00 28 04 00 25 AASOH Length TM OpCode Status CRCField Value DescriptionTM OpCode 0x2C TM OpCode for tag modification operationsTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM Options 0x00 Reserved for Future Use. Transaction Type Code 0xD203 Allegro/Title-21 code indicating operation to per-form.FF 05 2C ?? ?? 00 D2 03 ?? ??SOH Length TM OpCode Timeout (ms) TM Option Transaction Type Code CRC
Allegro/Title-21 Tag Commands72NACK ResponseFF 00 2C 04 00 65 2ESOH Length TM OpCode Status CRC
eGo/SeGo Tag Command Set73eGo/SeGo Tag Command SetThe eGo/SeGo tag commands are used to operate oneGo/SeGo tags and perform operations specific to those tags. These commands can only be used when the Tag Protocol of the reader is set to eGo/SeGo (0x001B or 0x001C) using Set Current Tag Protocol (93h). These commands cannot be run when in Bootloader mode, only in Application mode. eGo/SeGo Tag Commands OpCode Command Name0x21 Read Tag ID Single (21h)0x22 Read Tag ID Multiple (22h)0x24 Write Tag Data (24h)0x25 Lock Tag Data (25h)0x28 Read Tag Data (28h)0x2D Custom Tag Operations (2Dh)
eGo/SeGo Tag Command Set74Command SyntaxAll eGo/SeGo tag commands follow the same standard syntax. Each command has the following common fields followed by additional fields required for the specific operation being performed:Standard Request FieldsGroup Select OptionsThe following table defines the Command Type values to use for the desired Group Select Option when performing a Read Tag ID Single (21h), Read Tag ID Multiple (22h) or Write Tag Data (24h). The Group Select Option along with the Select Fields (Byte Address, Byte Mask and Word Data) determine which tags will respond to the specified query.Group Select OptionsField Value DescriptionTM OpCode 0xXX TM OpCode as defined in eGo/SeGo Tag Com-mandsTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM Options 0x01 Must be set to 0x01, indicating Command Type and eGo/SeGo specific fields to follow. Command Type [1 byte] Depending on the operation indicates either the Group Select Options to apply or a specific sub-command.Command Type Value Group Select Option Tag Selection Behavior0x00 GROUP_SELECT_EQ All tags in the field whose data EQUALS the specified Select Fields will respond.0x01 GROUP_SELECT_NE All tags in the field whose data does NOT EQUAL the specified Select Fields will respond.0X02 GROUP_SELECT_GT All tags in the field whose data is GREATER THAN the specified Select Fields will respond.
eGo/SeGo Tag Command Set750X03 GROUP_SELECT_LT All tags in the field whose data is LESS THAN the specified Select Fields will respond.0X04 GROUP_UNSELECT_EQ All tags except those in the field whose data EQUALS the specified Select Fields will respond.0X05 GROUP_UNSELECT_NE All tags except those in the field whose data does NOT EQUAL the specified Select Fields will respond.0X06 GROUP_UNSELECT_GT All tags except those in the field whose data is GREATER THAN the specified Select Fields will respond.0X07 GROUP_UNSELECT_LT All tags except those in the field whose data is LESS THAN the specified Select Fields will respond.Command Type Value Group Select Option Tag Selection Behavior
eGo/SeGo Tag Command Set76Read Tag ID Single (21h)The Read Tag ID Single command executes a query for tags matching the criteria specified by the Command Type and subsequent fields and returns the first tag found. Read Tag ID Single Request FieldsField Value DescriptionTM OpCode 0x21 TM OpCodeTimeout [2 bytes] Indicates how long the command should spend attempt-ing the operation, in milliseconds.TM Options Bit 0 •  1 - Indicates Command Type and additional fields to follow.Bit 4(LSB=bit 0))•  0 - Metadata flags must not be passed and Meta Data will not be returned. •  1 - Metadata flags must be passed and the corresponding Metadata shall be returned with the tag EPC. Metadata Flags (to specify more than one OR the val-ues together)0x0000 When no flags are set no meta data will be returned, only the tag EPC (including PC bits and tag CRC)0x0001 When bit 0 is set the Read Count will be returned0x0002 When bit 1 is set the LQI/RSSI will be returned0x0004 When bit 2 is set the Antenna ID will be returned0x0008 When bit 3 is set the Frequency will be returned0x0010 When bit 4 is set the Timestamp will be returned0x0020 When bit 5 is set the RFU (ThingMagic Only) will be returned0x0040 When bit 6 is set the Protocol is returned.Command Type [1 byte] Indicates the Group Select criteria to apply as defined in Group Select Options.Byte Address [1 byte]Byte Mask [1 byte]Word Data [8 bytes]
eGo/SeGo Tag Command Set77ExamplesAn example command:ACK ResponseNACK ResponseNo ResponseRead Tag ID Multiple (22h)The Read Tag ID Multiple command performs a search for the specified period of time then returns the number of tags that have been found. Afterwards, multiple Get Tag Buffer (29h) commands can be sent to receive the found tag IDs. Standard SyntaxThe search criteria for the Standard Syntax which allows control over the select criteria is specified by the Command Type and subsequent fields.FF 0E 21 ?? ?? 01 00 ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Time-out (ms) TM Option Command Type Byte Address Byte Mask Word Data CRCFF 0C 21 ?? ?? 01 ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Status TM Option Command Type Tag Data CRCFF 02 21 ?? ?? 01 ?? ?? ??SOH Length OpCode Status TM Option Command Type CRCFF 00 21 04 00 B4 83SOH Length TM OpCode Status CRC
eGo/SeGo Tag Command Set78Read Tag ID Multiple Request FieldsExamplesAn example command requesting :ACK ResponseNACK ResponseField Value DescriptionTM OpCode 0x22 TM OpCodeTM Options 0x01 Indicates Command Type and additional fields to follow.Search Flags 0x0000 Reserved for Future Use.Timeout [2 bytes] Indicates how long the command should spend attempt-ing the operation, in milliseconds.Command Type [1 byte] Indicates the Group Select criteria to apply as defined in Group Select Options.Byte Address [1 byte]Byte Mask [1 byte]Word Data [8 bytes]FF 10 22 01 00 00 ?? ?? 00 ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode TM Option Search Flags Timeout (ms) Command Type Byte Address Byte Mask Word Data CRCFF ?? 22 ?? ?? 01 00 00 ?? ?? ?? ?? ??SOH Length OpCode Status TM Option Search Flags Command Type Tag IDs Detected CRCFF 02 22 ?? ?? 01 ?? ?? ??SOH Length OpCode Status TM Option Command Type CRC
eGo/SeGo Tag Command Set79No ResponseMinimal SyntaxThe Read Tag ID Multiple command can also be used in a reduced syntax format. In this case only the Timeout is specified. This syntax performs a search for the specified period of time with no selection criteria, returning the number of tags that have been found. ExampleAn example response is as follows:Write Tag Data (24h)The Write Tag Data command writes data to a tag. The tag to write to, the location and the data to write are specified in the fields as defined below:FF 00 22 04 00 84 E0SOH Length TM OpCode Status CRCFF 02 22 03   E8 E5 6ASOH Length OpCode Timeout (ms) CRCFF 01 22 00 00 02 46 BASOH Length OpCode Status # Tag IDs Found CRC
eGo/SeGo Tag Command Set80Write Tag Data Request FieldsField Value DescriptionTM OpCode 0x24 TM OpCodeTimeout [2 bytes] Indicates how long the command should spend attempt-ing the operation, in milliseconds.TM OptionsNote:  TM Options field combines bits 0-4 indicating the verification method and bits 5 & 6 for authentication information. For the final TM Options setting, the two “fields” should be OR’d.[1 byte] excluding bits 5 & 6 (LSB = bit 0)•  0x00 = A READ is executed after the WRITE has reported success for verification. Lock if requested.Note:  When 0x00 the Command Type is implicity = 0x0D and the Command Type 1 byte field should be removed from the request command.•  0x01 = No verification is executed after WRITE reports success.•  0x02 = A READ_VERIFY is executed after the WRITE reports success for verification.•  0x03 = Only used with Command Type = 0x0E or 0x93. Indicates extra Select fields will be specified.bits 5 & 6 (LSB = bit 0) Specify authentication method to use:•  0x00 = authentication is disabled and Key values must not be passed.•  0x20 = RFU•  0x40 = authentication is enabled and Key values must be passed.•  0x60 = RFUCommand TypeNote:  If TM Options bits 0-4=0 then the Command Type is implicity = 0x0D and this byte should not be specified in the request command.0x0D Indicates the eGo/SeGo Write by Byte operation will be used.0x8D Indicates the eGo/SeGo Write by Page operation will be used0x0E Indicates the eGo/SeGo Write Multiple operation will be used.0x93 Indicates the eGo/SeGo Streamlined Group Select Equal Page Write operation will be used.
eGo/SeGo Tag Command Set81Lock [1 byte] •  0x00 = no lock•  0x01 = lock the data specified by Write DataWrite by Page won’t lock if authentication information is not specified.Write multiple won’t lockWrite Address [1|4byte] Indicates the start address of tag memory to be written:•  4 Byte Address when TM Option = 0xX0•  1 Byte Address otherwiseSelect Command Type [1 byte] Indicates the Group Select criteria to apply as defined in Group Select Options.Only passed when TM Option=0x03. For Command Type = 0x0E, indicates Select TypeFor Command Type = 0x93, RFUSelect Address [1 byte] Only passed when TM Option=0x03. Select Mask [1 byte] Only passed when TM Option=0x03. For Command Type = 0x0E, indicates Select MaskFor Command Type = 0x93, RFUTag ID | Select Data [8 bytes] When:•  Command Type = 0x0D, 0x0E or 0x8D: 8 bytes = Tag ID•  Command Type = 0x93 AND TM Options=0x03: [1 byte] = Select Data[7 bytes] = RFU•  Command Type = 0x93 AND TM Options=0x01 or 0x02[1 byte] = Select Address[1 byte] = Select Data[6 bytes] = RFUWrite Data [1|8 byte]  Indicates the data to be written to the specified tag starting at the specified address.•  1 Byte when Command=0x0D and 0x0E•  8 Bytes (1 page) when Command=0x8D and 0x93Key Address [1 byte] Only passed when authentication enabled in TM Options.Key Length in Bytes [1 byte] Only passed when authentication enabled in TM Options.Field Value Description
eGo/SeGo Tag Command Set82ExamplesAn example command requesting :ACK ResponseWhen Command Type = 0x0D or 0x0E,When Command Type = 0x8DWhen Command Type = 0x93NoteACK Status will be:0x0000 FAULT_SUCCESS_CODE0x0403 FAULT_WRITE_PASSED_LOCKED_FAILEDKey [0-N bytes] Only passed when authentication enabled in TM Options.Note:  Value passed with MSB first.FF 0F 24 ?? ?? 01 0D ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Timeout (ms) TM Option Command Type Lock Write Address Tag ID Write Data CRCFF 03 24 ?? ?? ?? 0D | OE ?? ?? ??SOH Length OpCode Status TM Option Command Type Verified Write Data CRCFF 0A 24 ?? ?? ?? 8D ?? ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Status TM Option Command Type Verified Write Data CRCFF 13 24 ?? ?? ?? 93 ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Status TM Option Command Type Tag ID Length Tag ID (length defined by ID Length)Verified Write Data CRCField Value Description
eGo/SeGo Tag Command Set83NACK ResponseNo ResponseLock Tag Data (25h)The Lock Tag Data command locks and unlocks a tag’s memory locations. The tag to (un)lock and memory location to be (un)locked are specified in the fields as defined below:Lock Tag Data Request FieldsFF 02 24 ?? ?? 01 0D ?? ??SOH Length OpCode Status TM Option Command Type CRCFF 00 24 04 00 E4 26SOH Length TM OpCode Status CRCField Value DescriptionTM OpCode 0x25 TM OpCodeTimeout [2 bytes] Indicates how long the command should spend attempt-ing the operation, in milliseconds.TM OptionsNote:  TM Options field combines bit 0 indicating general processing information and bits 5 & 6 indicating authentication method. For the final TM Options setting, the two “fields” should be OR’d.0x01 Indicates Command Type and additional fields to follow.bits 5 & 6 (LSB = bit 0) Specify authentication method to use:•  0x00 = authentication is disabled and Key values must not be passed.•  0x20 = RFU•  0x40 = authentication is enabled and Key values must be passed.•  0x60 = RFU
eGo/SeGo Tag Command Set84ExamplesAn example command requesting :Command Type 0x00 Performs a QueryLock, immediate followed by an UnLock0x01 Performs a QueryLock, immediate followed by a Lock0x0F LockByte operation. Performs QLock/Lock/QLock0x10 UnLock Byte. Performs QLock/UnLock/QLock0x11 QueryLock0x8F Lock Page. Performs QLock/Lock/QLock0x90 UnLock Page. Performs QLock/UnLock/QLockLock Address [1 byte] Indicates the address of tag memory to be (un)locked.Tag ID [8 byte] Indicates the Tag ID of the tag to be (un)locked.Key Address [1 byte] Only passed when authentication enabled in TM Options.Key Length in Bytes [1 byte] Only passed when authentication enabled in TM Options.Key [0-N bytes] Only passed when authentication enabled in TM Options.Note:  Value passed with MSB first.FF 0D 25 ?? ?? 01 0F ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Timeout (ms) TM Option Command Type Lock Address Tag ID CRCField Value Description
eGo/SeGo Tag Command Set85ACK ResponseWhen Command Type = 0x00 or 0x01When Command Type = all othersNACK ResponseNo ResponseNoteFor eGo Plus tags a key must be provided for lock/unlock operations. If a key is not provided then the tag will not respond. In that case a status=0x0400 is the expected command response.Read Tag Data (28h)The Read Tag Data command reads data from a tag. The tag to read from and the location to read the data from are specified in the fields as defined below:FF 03 25 ?? ?? ?? 00 | 01 ?? ?? ??SOH Length OpCode Status TM Option Command Type (Un)Lock Response CRCFF 04 25 ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Status TM Option Command Type Lock Response Query Lock Response CRCFF 03 25 ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Status TM Option Command Type Lock Response CRCFF 00 25 04 00 F4 07SOH Length TM OpCode Status CRC
eGo/SeGo Tag Command Set86Read Tag Data Request FieldsField Value DescriptionTM OpCode 0x28 TM OpCodeTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM OptionsNote:  TM Options field combines bits 0-4 indicating general processing information and bits 5 & 6 indicating authentication method. For the final TM Options setting, the two “fields” should be OR’d.[1 byte] Indicates Command Type and additional fields to follow:•  0x01 = For Standard Read Operationsbits 5 & 6 (LSB = bit 0) Specify authentication method to use:•  0x00 = authentication is disabled and Key values must not be passed.•  0x20 = RFU•  0x40 = authentication is enabled and Key values must be passed.•  0x60 = RFUCommand Type 0x0C eGo/SeGo Read, or Protected Read0x0B eGo/SeGo Data_Read0x12 eGo/SeGo Read_VerifyNote:  Requires a Write to occur immediately before.0x80 eGo/SeGo Streamline_Group_Select_Equal_Page_ReadNote:  Only works with eGo Plus tags. 0x92 eGo/SeGo Read_Verify_PageNote:  Requires a Write to occur immediately before.RFU [1 byte] Reserved for Future UseRead Byte Count [1 byte] Number of bytes starting at Read Address to read. Can request 1 to 8 bytes.Read Address [1 byte] Indicates the start address of tag memory to be read.
eGo/SeGo Tag Command Set87ExamplesAn example command requesting :ACK ResponseWhen Command Type = 0x80Tag ID | Select Data [8 bytes] When:•  Command Type = 0x0B, 0x0C, 0x12 or 0x92: 8 bytes = Tag ID•  Command Type = 0x80[1 byte] = Select Address[1 byte] = Select Data[6 bytes] = RFUKey Address [1 byte] Only passed when authentication enabled by TM Options.Key Length in Bytes [1 byte] Only passed when authentication enabled by TM Options.Key [0-N bytes] Only passed when authentication enabled by TM Options.Note:  Value passed with MSB first.FF 0F 28 ?? ?? 01 0C ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Timeout (ms) TM Option Command Type RFU Read Byte CountRead Address Tag ID CRCFF ?? 28 ?? ?? 01 0C ?? ?? ??SOH Length OpCode Status TM Option Command Type Read Data CRCFF ?? 28 ?? ?? ?? 80 ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Status TM Option Command Type Tag ID Length Tag ID (length defined by ID Length)Read Data CRCField Value Description
eGo/SeGo Tag Command Set88NACK ResponseNo ResponseCustom Tag Operations (2Dh) The Custom Tag Operations command provides access to several eGo/SeGo tag specific operations including: Fail, Success, Initialize, Resend, Read_All_Data, Read_All_Lock, and RN_Request. The operation to be performed is indicated by the Command Type field:Custom Tag Operations Request FieldsFF 02 28 ?? ?? 01 0C ?? ??SOH Length OpCode Status TM Option Command Type CRCFF 00 28 04 00 25 AASOH Length TM OpCode Status CRCField Value DescriptionTM OpCode 0x2D TM OpCodeTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM Options 0x01 Indicates Command Type to follow.Command Type 0x08 Fail0x09 Success0x0A Initialize0x15 Resend0x81 RN Request0x82 Tag Authentication. When specified the Key fields also must be passed.0x83 Mutual Authentication. When specified the Key fields also must be passed.
eGo/SeGo Tag Command Set89ExamplesAn example command requesting :ACK ResponseNACK ResponseNo ResponseKey Address [1 byte] Only passed when Command=0x82 or 0x83.Key Length in Bytes [1 byte] Only passed when Command=0x82 or 0x83.Key [0-N bytes] Only passed when Command=0x82 or 0x83.Note:  Value passed with MSB first.FF 04 2D ?? ?? 01 0C ?? ??SOH Length OpCode Timeout (ms) TM Option Command Type CRCFF 05 2D ?? ?? 01 0C ?? ... NN ?? ??SOH Length OpCode Status TM Option Command Type Tag Da ta(0-N based on Command Type)CRCFF 02 2D ?? ?? 01 ?? ?? ??SOH Length OpCode Status TM Option Command Type CRCFF 00 2D 04 00 75 0FSOH Length TM OpCode Status CRCField Value Description
eGo/SeGo Tag Command Set90
ATA Tag Command Set91ATA Tag Command SetThe ATA tag commands are used to perform operations specific to ATA tags. These commands can only be used when the Tag Protocol of the reader is set to ATA (0x001D) using Set Current Tag Protocol (93h). These commands cannot be run when in Bootloader mode, only in Application mode. ATA Tag Commands OpCode Command Name0x21 Read Tag ID Single (21h)0x22 Read Tag ID Multiple (22h) [Not yet Implemented]
ATA Tag Command Set92Command SyntaxAll ATA tag commands follow the same standard syntax. Each command has the following common fields followed by additional fields required for the specific operation being performed:Standard Request FieldsField Value DescriptionTM OpCode 0xXX TM OpCode as defined in ATA Tag CommandsTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.
ATA Tag Command Set93Read Tag ID Single (21h)The Read Tag ID Single/Tag Detect command performs a search operation and returns the first ATA tag it finds. Read Tag ID Single Request FieldsExamplesAn example, without TM Options, command:Field Value DescriptionTM OpCode 0x21 TM OpCodeTimeout [2 bytes] Indicates how long the command should spend attempting the operation, in milliseconds.TM OptionsNote:  This and following fields are optional.Bit 4(LSB=bit 0))•  0 - Metadata flags must not be passed and Meta Data will not be returned. •  1 - Metadata flags must be passed and the corresponding Metadata shall be returned with the tag EPC. Metadata Flags (to specify more than one OR the val-ues together)0x0000 When no flags are set no meta data will be returned, only the tag EPC.0x0001 When bit 0 is set the Read Count will be returned0x0002 When bit 1 is set the LQI/RSSI will be returned0x0004 When bit 2 is set the Antenna ID will be returned0x0008 When bit 3 is set the Frequency will be returned0x0010 When bit 4 is set the Timestamp will be returned0x0020 When bit 5 is set the RFU (ThingMagic Only) will be returned0x0040 When bit 6 is set the Protocol is returned.FF 02 21 ?? ?? ?? ??SOH Length OpCode Time-out (ms) CRC
ATA Tag Command Set94ACK ResponseNACK ResponseNo ResponseRead Tag ID Multiple (22h)[Not yet implemented]FF 0A 21 ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ??SOH Length OpCode Status Tag ID CRCFF 00 21 ?? ?? ?? ??SOH Length OpCode Status CRCFF 00 21 04 00 B4 83SOH Length TM OpCode Status CRC
Gen2 Tag Commands95Gen2 Tag CommandsThe Gen2 tag commands are used to operate on Gen2 tags and perform operations specific to those tags. These commands can only be used when the Tag Protocol of the reader is set to Gen2 (0x0005) using Set Current Tag Protocol (93h). These commands cannot be run when in Bootloader mode, only in Application mode.Gen2 Tag Commands OpCode Command Name Arguments Return BL App0x21 Read Tag Single (21h) Timeout (ms) Tag ID N Y0x22 Read Tag Multiple (22h) Timeout (ms), Antennas Flag Multiple Tag IDs NY0x23 Write Tag EPC (23h) Timeout (ms), lock bit, password, tag IDNone N Y0x24 Write Tag Data (24h) Timeout (ms), lock bit, address, data None N Y0x25 Lock Tag (25h) Timeout (ms), proto-col specific data None N Y0x26 Kill Tag (26h) Timeout (ms), proto-col specific data None N Y0x28 Read Tag Data (28h) Timeout (ms), Address, Tag ID Tag data N Y0x29 Get Tag Buffer (29h) various various N Y0x2A Clear Tag Buffer (2Ah) none none N Y0x2D Gen2 Tag Specific (2Dh) Timeout (ms), Chip Type, option, Kill password, Access password, Tag IDnone N Y0x2E Erase Block Tag Specific (2Eh)Timeout (ms), chip type, option addr, mem bank, number of words to erasenone N Y
Gen2 Tag Commands96Tag Singulation/Select FunctionalityMany of the Gen2 tag commands now support the ability to singulate a specific tag or inventory only tags matching a defined criteria, i.e. matching on values in the EPC, TID and User Memory banks. Select Algorithm and ParametersThe algorithm used to perform a Gen2 Select and its impact on subsequent Gen2 Query operations on a population of tags is determined by several user defined settings which either correspond directly to or are used to determine the various Gen2 Select and Query parameters as defined by the EPCGlobal Gen2 v1.2 Specification. The current user controlled options are:Gen2 Session (User Controlled)This setting determines which tag inventory flag is altered when a tag responds to a Gen2 Query (each flag has a unique persistence profile, as defined by the Gen2 Specification). The value of Gen2 Session is set using the Set Protocol Configuration (9Bh) command. The supported values are 0, 1, 2, or 3. Select Invert (User Controlled)This setting is used to determine the Gen2 Action value sent in the Gen2 Select command. The value of Select Invert is defined using bit 3 of the Select Option field in the Tag Singulation Fields. The supported values are: 0 (False) - Tags which match the Select criteria are to respond. Set Gen2 Action=0. 1 (True) - Tags which DO NOT match the Select criteria are to respond. Set Gen2 Action=4.The settings specified for Gen2 Session and Select Invert determine the settings within the Select command which is sent before the corresponding Gen2 Query and the settings in the subsequent Gen2 Query(s). These implicit settings used by the Gen2 Select are:Gen2 Action (defined by Select Invert)This parameter can be one of 8 values, as defined by the Gen2 specification, which determine which of 4 possible flag actions (assert, de-assert, negate, or leave alone) will be done if the criteria matches and, similarly, which of the 4 possible flag actions will be done if the criteria does not match. Only two values are currently used:
Gen2 Tag Commands97 0 - Assert (or put in state “A” for inventory flags) the target flag if there IS a match; de-assert (or put in state “B” for inventory flags) the target flag if there IS NOT a match. 4 - Assert (or put in state “A” for inventory flags) the target flag if there IS NOT a match; de-assert (or put in state “B” for inventory flags) the target flag if there IS a matchGen2 Target (Static)This setting determines which inventory flag or SL flag is going to have its state determined by the matching algorithm. Currently always set to ‘4’, indicating the Gen2 Select command modifies a tag’s SL flag.The following table defines the currently supported User Settings and the resulting behavior of the Gen2 Select and Gen2 Query:Gen2 Select and Query BehaviorSelect ProcessThe following defines how the Select process works when attempting to select tags that match a defined criteria:User Settings Select Behavior Query Behavior Comments•  Gen2 Session = 0,1,2,3•  Invert = 0Gen2 Select Settings:•  Target = 4•  Action = 0If tags match the criteria, put their SL flag in the ‘Assert’ state; and SL of non-matching tags into the ‘De-assert’ state.Gen2 Query Settings:•  SEL = 3•  Target = “A”•  Session = [User Defined]Ask tags to respond if their SL flag is in the ‘Assert’ state and their session appropriate inventory flag is in the ‘A’ state. Once a tag responds, it puts the inven-tory flag in the ‘B’ state, pre-venting further matches until the inventory flag’s Flag Persistence Rules returns it to the ‘A’ state.Tag state persistence before a Query is based on SL flag persistence; Tag state persistence after a Query is based on inventory flag corre-sponding to the Session used.•  Gen2 Session = 0,1,2,3•  Invert = 1Gen2 Select Settings:•  Target = 4•  Action = 4If tags match the criteria, put their SL flag in the ‘De-assert’ state; and SL of non-matching tages into the ‘Assert’ state.
Gen2 Tag Commands981.    The Reader issues a Select containing the desired tag memory values and instructions for the tag to assert if its contents matches that specified in the request (and, conversely, de-assert the SL flag if it does not match) as defined by the Tag Singulation Fields. The de-assert will generally have no effect because the de-asserted state is the default, but is helpful if tags still have their SL flag asserted from a previous Select.–   Tags that are selected, at this point, are not selected within a specific Session. The persistence of their state depends entirely on that of the SL flag.2.    A Query is issued which specifies the flag settings which must match before a tag will respond:–   The SL flag must be asserted–   The Session flag for session 0, 1, 2, or 3 (specific Session value is in the Query and depends on the reader’s Session setting) must be ‘A’ (the default value).3.    Matching tags will respond to the Query, but after responding, will change their own state in the following way:–   The Inventory flag corresponding to the Session specified in the Query will be changed to the ‘B’ state.–   The SL flag will remain asserted (per its ongoing Flag Persistence Rules)4.    If subsequent indentical Queries are issued (identical to the first), this tag will remain silent until the Flag Persistence Rules for the inventory flag that was put into the ‘B’ state cause the flag to fall back into the ‘A’ state. At that point, the tag will respond again (assuming that the persistence rules of the SL flag are still keeping it in the ‘assert’ state).NoteA search with Invert=1 specified will perform the same steps except in step 1 the tag will “de-assert if its contents matches that specified in the request (and, conversely, assert the SL flag if it does not match) as defined by the Tag Singulation Fields.”NoteA Select will be performed once per antenna when Select is specified during a Read Tag Multiple (22h) with multiple antennas configured.Flag Persistence RulesSession 0 Keeps state as long as tag is energized
Gen2 Tag Commands99 Returns to default state as soon as the tag is no longer energizedIts state will often get reset during the course of executing a single command, for example, between inventory rounds, or when there is a frequency hop, or when a new antenna is selected during a Read Tag Multiple search. the result is that when the session is set to ‘0’, all tags will respond to every appropriate Query, considerably lengthening the time to inventory a large population of tags. Session 0 is typically used for operations where a single tag is expected to be in the field, for example, printers.Session 1 Keeps its state between 0.5 and 5 seconds, regardless of whether the tag is energized or not.The intent is that when the session is set to 1 the tag will respond to an appropriate Query immediately, and then respond periodically if the Query is repeated by the reader. This allows a larger population of tags to be reliable read. Session 1 is typically used in applications where a large population of tags is being continuously inventoried allowing for it to be determined when tags enter and leave the field.Session 2, 3 and SL Flags Keeps state as long as the tag is energized. Keeps its state for at least 2 seconds after the tag is no longer energized and will refresh its state if the tag is re-energized during that period.The intent is that when the session is set to ‘2’ or ‘3’ a tag will only respond once to an appropriate Query, then remain silent as the Query is repeated by the reader to elicit responses from other tags. Typically used in operations when you are performing an action on tag or population of tags which you do not want/need repeated.Operations supporting Tag Singulation/SelectThe commands currently supporting tag singulation through Select are: Read Tag Single (21h) Read Tag Multiple (22h) Write Tag Data (24h) Lock Tag (25h) Kill Tag (26h)
Gen2 Tag Commands100 Read Tag Data (28h)The following fields apply to all the specified commands. Please check each command for exact order, and any exceptions, as they may not all correspond with the order below.Tag Singulation FieldsField Values DescriptionSelect Option 0x00 Select functionality is disabled. First tag found will be the tag operated on. No other Tag Singulation Fields should be specified. Option field must always be specified.0x01 Select on the value of the EPC. Requires all fields except the Select Address field.0x02 Select on contents of TID memory bank (Gen2 bank 0x02). Requires all fields.0x03 Select on contents of User Memory memory bank (Gen2 bank 0x03). Requires all fields.0x04 Select on contents of the EPC memory bank (Gen2 bank 0x01). Requires all fields.0x08 Sets Invert Flag. This results in tags NOT matching the specified Tag Singulation Fields will be returned, as defined in Select Algorithm and Parameters.Select Address 4 bytes Contains the offset, in bits, within the memory bank, speci-fied by the Option value, at which the comparison is to start. NOTE: specifying Option=0x04 and Select Address=0x20 is the equivalent, for Gen2 v1 tags, of specifying Option=0x01, both specify a comparison against the tag EPC ID data.Note:  Addresses are always zero-based. Specifying 0x00 indicates starting at the first address location.Select Data Length 1 byte Contains the length of the data (Select Data) to be com-pared, in bits, to the EPC when Option=0x01, or to the data beginning at Select Address for other options.Select Data M bytes Contains the data to be compared against the specified tag data (memory bank and address, or EPC as specified by the Option value)
Gen2 Tag Commands101Read Tag Single (21h)The Read Tag Single command will search for a tag for the specified timeout or a single tag is found, whichever comes first. The search criteria is specified using the Tag Singulation Fields. If Option=0x00 is specified it will return with the first tag it finds, otherwise it will only return Success and the found EPC if a tag matching the specified criteria is found. If no tag is read, a fault code is returned. In addition to the Tag Singulation Fields the basic Read Tag Single command takes a 16-bit timeout value in milliseconds. The command will return after a tag is found or the timeout expires, whichever happens first.The basic syntax which returns only the tag EPC is defined in Get Tag EPC. With additional Option bits set Read Tag Single can also return Tag Read Meta Data using the syntax in Get Tag EPC and Meta Data.Get Tag EPCThe following example shows a search requesting a tag matching the following criteria for a max timeout of 1000 ms. This example uses the Tag Singulation/Select Functionality with Option=0x03, indicating Tag Selection based on the contents of User Memory, specifically:Memory Bank = User Memory. Starting Address = bit 32 Select Data = 0x1234If Option=0x00 or 0x01 were used then the unused Tag Singulation Fields must be removed from the request.The response to this command varies depending upon the number of bits in the tag EPC of the tag found. The general response format is shown here:FF 0A 21 03   E8 03 00 00 00 20 10 12 34 E5 ACSOH Length OpCode Timeout (ms) Option Select Address Select Data LengthSelect Data CRC
Gen2 Tag Commands102Get Tag EPC and Meta DataIn addition to getting the tag EPC value returned you can also get Tag Read Meta Data for the found tag. This version of Read Tag Single requires bit 4 of the Option flag to be set and takes an additional Metadata Flags field which defines what metadata will be returned The following table lists the supported values for these fields.FF M+3 21 00 00 03 M bytes ?? ?? ?? ??SOH Length OpCode Status Option EPC TagCRC CRC
Gen2 Tag Commands103Read Tag Single Get EPC and Metadata Request FieldsA response can contain the following information:Field Value DescriptionOption Bit 4=0 (0x0X) No Metadata flags are specified and Meta Data will not be returned. This is the Get Tag EPC syntax. The lower bits (X) are specified as defined by Tag Singulation/Select Functionality.Bit 4=1 (0x1X) Indicates that Metadata flags are to follow and the corresponding Metadata shall be returned with the tag EPC. The lower bits (X) are specified as defined by Tag Singulation/Select Functional-ity.Metadata Flags (to specify more than one OR the values together)0x0000 When no flags are set no meta data will be returned, only the tag EPC (including PC bits and tag CRC)0x0001 When bit 0 is set the Read Count will be returned0x0002 When bit 1 is set the LQI/RSSI will be returned0x0004 When bit 2 is set the Antenna ID will be returned0x0008 When bit 3 is set the Frequency will be returned0x0010 When bit 4 is set the Timestamp will be returned0x0020 When bit 5 is set the RFU (ThingMagic Only) will be returned0x0040 When bit 6 is set the Protocol is returned.These fields are followed by the Tag Singulation/Select Functionality, used the same as defined in the Get Tag EPC syntax, if necessary.
Gen2 Tag Commands104Read Tag Single Get EPC and Metadata Response FieldsAn example command requesting AntennaID and Timestamp Field Length ValueSOH 1 byte 0xFFLength 1 byte Based on data returnedOpCode 1 byte 0x21Options 1 byte As sent in requestMetadata Flags 2 bytes Metadata contained in responseRead Count11 byte Tag EPC/Antenna Read CountRSSI11 byte Return Signal Strength IndicatorAntenna ID11 byte Antenna ID, 4 MSBs for TX and 4 LSBs for RXFrequency13 bytes Frequency in kHzTimestamp14 bytes RTC TimestampRFU12 bytes Reserved for Future Use - ThingMagic OnlyProtocol ID 1 byte Protocol ID of tag readEPC ID N bytes Tag EPC.Tag CRC 2 bytes Tag EPC CRCCRC 2 bytes Message CRC1 - Conditionally returned depending on the Metadata Fields specified in the request.
Gen2 Tag Commands105Metadata Flags = 0x0004 OR 0x0010 = 0x0014with no tag singulation criteria, just return the first tag found, is as follows: Here is an example response to the example request specified above. The response contains the tag EPC info of the found tag and the requested tag read metadata: AntennaID and Timestamp:Here is another example request and response showing the use of Tag Singulation/Select Functionality and getting the tag metadata for the specified tag:This command requests the same tag read metadata as the previous example (AntennaID and Timestamp) except now it is selecting a tag with a specific EPC value (EPC=0x111122223333444455556666), which requires adding the appropriate Tag Singulation Fields after the Read Tag Single Get EPC and Metadata Request Fields along with FF 05 21 01 E8 10 00 14 2F 6DSOH Length OpCode Timeout Options Metadata Flags CRCFF 16 21 00 00 10 00 14 SOHLength OpCode Status Options Metadata Flags11 00 BB5F 04 01 23 45 67 89 ABCDEF 01 23 45 67 E6 C8Ant ID Timestamp Tag EPC Tag CRC37 C4CRC
Gen2 Tag Commands106updating the Option field to set the appropriate flag for the tag singulation based on EPC valueThe response contains the requested metadata and the tag EPC matching the requested tag EPC:Read Tag Multiple (22h)The Read Tag Multiple command supports several different levels of functionality. In addition to performing a Basic Search Operation for all tags in the field it can also perform advanced searching and perform operations on the tags found. The different syntax for Read Tag Multiple are defined as follows: Basic Tag Inventory - Searches for and returns all tags in the field. Tag Inventory with Select - Searches for and returns all tags in the field meeting Select criteria as defined by Tag Singulation Fields specified. Tag Inventory With Embedded Operations - Allows for operations (Write Tag Data, Lock Tag, Kill Tag, Read Tag Data) to be performed on each tag inventoried.FF 12 21 01 E8 11 00 14SOH Length OpCode Timeout Options Metadata Flags60 11 11 22 22 33 33 44 44 55 55 66 66 9F CESelect Data LengthSelect Data (EPC) CRCFF 16 21 00 00 11 00 14 SOH Length OpCode Status Options Metadata Flags22 0F C8 CD B7 11 11 22 22 33 33 44 44 55 55 66 66 18 35Ant ID Timestamp Tag EPC Tag CRCFE 7DCRC
Gen2 Tag Commands107Basic Tag InventoryThe Read Tag Multiple command performs a search for the specified period of time then returns the number of tags that have been found. Afterwards, multiple Get Tag Buffer commands can be sent to receive the found tag EPCs along with tag read metadata, including the antenna the tag was read on. The command allows the user to specify the method to use when multiple monostatic antennas are connected. The user can set the two byte Search Flag to enable automatic Multi-Antenna Search:
Gen2 Tag Commands108Read Tag Multiple Search FlagsFor example, the syntax for a Read Tag Multiple with automatic multi-antenna search starting with antenna1 is:The response format for both is the following:2Flag Value Antenna Usage0x0000 Use single antenna as configured by the most recent Set Antenna command.10x0001 Automatically search on both monostatic antennas, starting with Antenna 1. The search cycles through antennas moving to the next antenna when no more tags are found on the current antenna. It stops when the search timeout expires.10x0002 Automatically search on both monostatic antennas, starting with Antenna 2. The search cycles through antennas moving to the next antenna when no more tags are found on the current antenna. It stops when the search timeout expires.0x0004 An embedded command is specified in the request and will be executed on each inventoried tag. Note:  This bit should only be set when using the Tag Inventory With Embedded Operations syntax.Note:  1- Only one of these flags should be set since both Antenna 1 and 2 cannot be the starting antenna.2 -Multiple Flags can be set (perform a binary OR) to specify different behaviors. ex: Search Flags = 0x0006 indicates a multiple antenna search starting on antenna1 is to be performed and the embedded command specified it to be executed on each tag.FF 04 22 00 01 03   E8 3F 8ESOH Length OpCode Antennas Flag Timeout (ms) CRCFF 01 22 00 00 02 46 BASOH Length OpCode Status # Tag IDs Found CRC
Gen2 Tag Commands109Tag Inventory with SelectIf you want to inventory only tags meeting a specific criteria this syntax should be used. The search criteria is specified using the Tag Singulation Fields. If Option=0x00 is specified it will perform the same search as the Basic Tag Inventory syntax. Otherwise, it will return the number of tags found matching the specified criteria. The tag EPCs and Meta Data will be available in the Tag Buffer. If no tags are found, a fault code is returned. The required fields are as follows:Read Tag Multiple with Select FieldsHere is an example request and response showing the use of Tag Singulation/Select Functionality to inventory tags which meet a specific criteria:This command will inventory all tags with an EPC value ending in 0x66, which requires adding the appropriate Tag Singulation Fields to the Basic Tag Inventory syntaxField Value DescriptionSelect Options [1 byte] The Options value of the Tag Singulation FieldsSearch Flags [2 bytes] Read Tag Multiple Search Flags indicating antenna usage. Bit 3 must be 0, no embedded commands.Timeout [2 bytes] Indicates how long the command should spend searching.Access Password [4 bytes] The Access Password of the tags expected to be inventoried, if they are locked. If the tags are not locked specify 0x00000000. Note:  If the memory used for tag singulation of inventoried flags is read locked and have different passwords, only tags with matching passwords will be successfully inventoried.Tag Singulation Fields The remaining, appropriate fields depending on the value of Select Options.FF 0F 22 04 00 00 03 E8SOH Length OpCode Options(EPC Mem) Search Flags Timeout
Gen2 Tag Commands110NoteThe Select Options field of the Tag Singulation Fields in the request is specified at the beginning of the command followed by the Search Flags, Timeout, Access Password then the rest of the Tag Singulation Fields. This is different than the typical format for Select fields. Also, this syntax always requires an Access Password be specified. If the tags are not locked it can be set to 0x00000000The response contains the number of tags found matching the Select criteria specified. Use Get Tag Buffer (29h) to access the tag EPCs and Tag Read Meta Data:Tag Inventory With Embedded OperationsIn addition to inventorying tags, Read Tag Multiple can be used to perform an operation on each tag in a population of tags. Starting with the Tag Inventory with Select syntax to define the population of tags the operation is to be performed on, the Search Flag bit 3 (0x0004) can be set to indicate embedded commands are to be performed on the inventoried commands. The required fields are as follows:00 00 00 00 00 00 00 78 08 66 DEC0Access Password Select Address (bits) Select Data Length (bits)Select Data  CRCFF 04 22 00 00 04 00 00 02 B7 6ESOH Length OpCode Status Options(EPC Mem) Search Flags Tag Found CRC
Gen2 Tag Commands111Read Tag Multiple Embedded Command FieldsHere is an example request and response showing the use of Tag Singulation/Select Functionality to inventory tags which meet a specific criteria and then setting the Access Field Value DescriptionSelect Options [1 byte] The Options value of the Tag Singulation FieldsSearch Flags [2 bytes] Bit 3 of the Read Tag Multiple Search Flags must be set indicating this request contains embedded command(s).Timeout [2 bytes] Indicates how long the command should spend searching AND performing the embedded command. It may be desirable to specify a longer timeout if a large number of tags are likely to get the embedded command executed on them. Access Password [4 bytes] The Access Password of the tags expected to be invento-ried, if they are locked. If the tags are not locked specify 0x00000000. Note:  If inventoried flags are locked and have different passwords, only tags with matching passwords will get a successful execution of the embedded command.Tag Singulation Fields The remaining, appropriate fields depending on the value of Select Options.Embedded Command Count [1 byte] The number of embedded commands to follow. [Currently only supports one]Embedded Command Length [1 byte] Length of embedded commands. Follows standard Length value calculation: number of bytes after OpCode.Embedded Command OpCode [1 byte] The OpCode of the embedded command. Currently sup-ports:•  Write Tag Data (24h)•  Lock Tag (25h)•  Kill Tag (26h)•  Read Tag Data (28h)The fields and values required by the embed-ded command. Note:  The embedded commands do not support Tag Singulation as it is already performed during the inventory operation. The Options field for the embedded command must be 0x00.Note:  The Timeout field for embedded commands must be 0x0000.
Gen2 Tag Commands112password on each using Write Tag Data (24h) as an embedded command:This command will inventory all tags with an EPC value ending in 0x34, which requires adding the appropriate Tag Singulation Fields to the Basic Tag Inventory syntax then will use Write Tag Data (24h) to write 0x12345678 into the Reserved Memory Bank starting at Word address 0x00000002 (Access Password)The response contains the number of tags found matching the Select criteria specified and the number of embedded command operations which succeeded and failed. Use Get Tag Buffer (29h) to access the tag EPCs and Tag Read Meta Data for the Tags Found. Tags in the buffer may or may not have had successful execution of the embedded command on them:NoteDepending on the Gen2 Session/User Mode used the Operations Succeeded/Failed counts can be misleading since in Session 0, for example, the tag may respond many times during an inventory round and the command may be attempted many times. This would result in counts higher than the actual number of tags the operation succeeded or failed on. The above commands were run in User Mode = Portal.Write Tag EPC (23h)The Write Tag EPC command takes the following data elements:FF 1E 22 04 00 04 03 E8 00 00 00 00 00 00 00 78 08 34SOH Length OpCode Options(EPC Mem) Search Flags Timeout Access Password Select Data Address (bits) Select Data Length (bits)Select Data 01 0C 24 03 E8 00 00 00 00 02 00 12 34 56 78 ?? ??Embd Cmd CountEmbd Cmd LengthEmbd Cmd OpCodeEmbd Cmd Timeout(Not Used)Embd Cmd Options (Must be 0x00)Write Address (Words) Write Mem-BankWrite Data CRCFF 0A 22 00 00 04 00 04 03 01 24 00 03 00 00 ?? ??SOH Length OpCode Status Options Search Flags Tag Found Embd Cmd CountEmbd Cmd OpCodeOperations Succeeded Operations Failed CRC
Gen2 Tag Commands113The reader sends a Fault Code / ACK response back to the host.An example of Write Tag EPC command sequence of events and format is shown next:1.    Starts a timer on the reader.2.    Wakes the tag.3.    Programs the tag with the EPC ID 4.    Reads the tag and verifies if the write succeeded.NoteThe verify operation uses the same power level as the write operation. It does not change to the Read power level.5.    Sends back an ACK if OK or a fault code for timeout or other faults.Bytes 6 and 7, identified as Reserved for Future Use (RFU) are ignored, although still required in the command. EPC values up to 496-bits are supported, depending on EPC Length parameter setting in Set Reader Configuration(9Ah).Write Tag Data (24h)The Write Tag Data command writes to the specified memory bank and data address location within that memory bank of a tag. The tag which will be written to can be specified using the Tag Singulation Fields or, if Option=0x00 of the Tag Singulation Fields is specified, it will attempt to write to the first tag it finds. If no tag is in the field, the memory FF M + 4 23 03   E8 00 00 M bytes ?? ??SOH Length OpCode 1Timeout (ms)1.16-bit timeout value in milliseconds. Due to tag difference some tags may require more time to write than others. Experimentationmay be required to determine the optimal timeout.2RFU2.Reserved for Future Use, this field is required but ignored.3RFU3.Reserved for Future Use, this field is required but ignored4Tag EPC (M bytes)4.Up to 496-bit (Depending on EPC Length parameter set in Set Reader Configuration) tag ID to write to the Tag.CRCFF 0C 23 03   E8 00 00 11 22 33 44 55 66 77 88 5D D8SOH Length OpCode Timeout (ms) RFU RFU EPC ID CRC
Gen2 Tag Commands114location doesn’t exist or is unwriteable, or the Select criteria cannot be satisfied a fault code is returned. In addition to the Tag Singulation Fields the Write Tag Data command takes several fields which specify the data which will be written to the tag. These fields are:
Gen2 Tag Commands115Write Tag Data FieldsThe following example will attempt to write to Reserved Memory to set the Kill password=0x11112222. It will write this data to a tag matching the following criteria for a max timeout of 1000 ms.Memory Bank = User Memory. Starting Address = bit 32 Select Data = 0x1234The Reserved Memory bank is not locked so the Access Password is zeroField Value DescriptionWrite Address 4 bytes The Address field is the offset in the specified Memory Bank, in 16-bit words, where the contents of the Data field is written. It cor-responds to the WordPtr argument in the Gen2 specification. Note:  Addresses are always zero-based. Specifying 0x00 indicates starting at the first address location.Write MemBank 1 byte The MemBank field specifies which of the tag’s memory banks the data is to be written to. The values correspond to the Memory Bank values as specified in the Gen2 specification. They are:0x00 = Reserved0x01 = EPC0x02= TID0x03 = User MemoryWrite Data N bytes The data to be written to the tag in Memory bank [MemBank] starting at address [Address].Access Password 4 byes The Access Password for the tag, if the tag is locked. For an unlocked tag AccessPwd=0x00000000.Note:  When Option=0x00 is specified the Access Password is not used.FF 17 24 03   E8 03 00 00 00 00 00 00 00 00 00 00 00 00 20 10 12 34SOH Length OpCode Time-out (ms) Option Write Address Write MemBank Access Password Select Address Select Data LengthSelect Data11 11 22 22 3E 71Write Data CRC
Gen2 Tag Commands116If Option=0x00 or 0x01 is used then the unused Tag Singulation Fields must be removed from the request.NoteIf Option=00, the write tag data is performed without any select criteria resulting the first tag found being written. In that case there is no way to determine what tag gets written to unless there is only one tag in the RF field.Lock Tag (25h)The Lock Tag command locks the specified memory bank of a tag. The tag which will be locked can be specified using the Tag Singulation Fields or, if Option=0x00 of the Tag Singulation Fields is specified, it will attempt to lock the first tag it finds. If no tag is in the field, the memory location doesn’t exist or is unlockable, or the Select criteria cannot be satified a fault code is returned. In addition to the Tag Singulation Fields the Lock Tag command takes several fields which specify how the tag is to be locked. These fields are:Lock Tag FieldsThe values of the Mask and Action bits indicate how a tag is to be locked. The 10 Least Significant Bits of each 16-bit argument are used to indicate the lock behavior for each Field Value DescriptionAccessPwd 4 byes The Access Password for the tag. In order to lock a tag the Access Password must be non-zero. To set the access pass-word using the Write Tag Data (24h) command.Mask Bits12 bytes The Mask bits specify which fields should be modified according to the Actions bits. When a Mask Bit =0 the corresponding Action bit is not applied and the current lock setting is retained. When a Mask Bit =1 the corre-sponding Action bit is applied and the new lock setting is implemented.Action Bits12 bytes  The Action bits specify whether to assert or deassert a lock behavior for the associated memory location. Action Bits are only applied if the corresponding Mask Bits =1.1-The Mask and Action bits correspond to the identically named fields described in Section 6.3.2.10.3.5 of the Gen2 specification.
Gen2 Tag Commands117memory bank (Action Bits) and which of those behaviors to apply (Mask Bits). These bits and their corresponding behaviors are:For each bit in the Mask field where Set?=1 the corresponding Action bit will be applied and the specified lock setting (R/W, W. Permanent) will be asserted (1) or de-asserted (0). Please see the Gen2 specification for more information on Lock Action functionality.NotePassing 0xFFFF in the Mask field and 0x0000 in the Action field unlocks all the memory banks.The following example shows an attempt to apply a temporary (not permanent) Write lock on the EPC memory (Option=0x01) of a tag whose EPC ID=0x111122223333444455556666 and whose access password=0x11223344:Kill Tag (26h)The Kill Tag command kills the specified tag. The tag which will be killed can be specified using the Tag Singulation Fields or, if Option=0x00 of the Tag Singulation Fields is First Byte  Second ByteBit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0Unused Kill Pwd Access Pwd EPC Mem TID Mem User MemMask X X X X X X Set? Set? Set? Set? Set? Set? Set? Set? Set? Set?Action XXXXXXR/WPermR/WPermW PermW PermW PermFF 18 25 03 E8 01 11 22 33 44 00 20 00 20 60h 11 11 22 22 33 33 44 44 55 55 66 66 9E 7ASOH Length OpCode Timeout (ms) Option Access Password Mask Bits Action Bits Select Data LengthSelect EPC ID  CRC
Gen2 Tag Commands118specified, it will attempt to kill the first tag it finds. If no tag is in the field, the kill password is zero, or the Select criteria cannot be satified a fault code is returned. In addition to the Tag Singulation Fields the Kill command takes the tag’s Kill Password and an extra 1 byte field for future use (RFU). The following example shows an attempt to kill a tag whose EPC ID=0x112233445566778899AA and whose Kill password=0x11112222:NoteIf the tag’s kill password is set to 0, the protocol does not allow the tag to be killed. A non-zero kill password must be set (using the Write Tag Data command) before the kill command succeeds. The RFU field should be set to 0.Read Tag Data (28h)The Read Tag Data command reads the specified memory bank at data address location within that memory bank of a tag. The tag which will be read can be specified using the Tag Singulation Fields or, if Option=0x00 of the Tag Singulation Fields is specified, it will attempt to read from the first tag it finds. If no tag is in the field, the memory location doesn’t exist or is read locked, or the Select criteria cannot be satified a fault code is returned. In addition to the Tag Singulation Fields the Read Tag Data command takes several fields which specify the data which will be read from the tag. These fields are:FF 13 26 03 E8 01 11 11 22 22 00 50 11 22 33 44 55 66 77 88 99 AA DD DBSOH Length OpCode Timeout (ms) Option Kill Password RFU Select Data LengthSelect EPC ID  CRC
Gen2 Tag Commands119Read Tag Data FieldsThe Basic syntax which returns only the requested Tag Data is defined in Get Tag Data. With additional Option bits set, Read Tag Data can also return Tag Read Meta Data using the syntax in Get Tag Data and Meta Data.Field Value DescriptionRead MemBank 1 byte The MemBank field specifies which of the tag’s memory banks the data is to be read from. The values correspond to the Memory Bank values as specified in the Gen2 specification. They are:0x00 = Reserved0x01 = EPC0x02= TID0x03 = User MemoryRead Address 4 bytes The Address field is the offset in the specified Memory Bank, in 16-bit words, to start reading from. It corresponds to the WordPtr argument in the Gen2 specification. Note:  Addresses are always zero-based. Specifying 0x00 indicates starting at the first address location.WordCount 1 byte The number of words (16 bit chunks) of data to read from memory bank [MemBank] starting at offset [ReadAddress].Access Pass-word 4 byes The Access Password for the tag, if the tag is read locked. For an unlocked tag AccessPwd=0x00000000.
Gen2 Tag Commands120Get Tag DataThe following example will attempt to read the Kill Password (the first 2 words) from Reserved Memory. It will read this data from a tag matching the following criteria for a max timeout of 1000 ms.Memory Bank = User Memory. Starting Address = bit 32 Select Data = 0x1234The Reserved Memory bank is not locked so the Access Password is zeroIf Option=0x00 or 0x01 is used then the unused Tag Singulation Fields (including the Access Password) must be removed from the request.The response to this Read Data command example is:Read Tag Data ResponseThe length field of the data returned is 2 times the WordCount value in the original command, because the return packet length is counted in bytes, plus 1 byte for the Option specified.Get Tag Data and Meta DataIn addition to getting the tag data returned you can also get Tag Read Meta Data for the found tag. This version of Read Tag Data requires bit 4 of the Option flag to be set and takes an additional Metadata Flags field which defines what metadata will be returned. The following table lists the supported values for these fields.FF 14 28 03   E8 03 00 00 00 00 00 02 00 00 00 00SOH Length OpCode Time-out (ms) Option Read MemBank Read Address Word-Count Access Password00 00 00 20 10 12 34 D1 E7Select Address Select Data LengthSelect Data CRCFF 05 28 00 00 03 11 11 22 22 10 BFSOH Length OpCode Status Option Data CRC
Gen2 Tag Commands121Read Tag Data Get Data and Metadata Request FieldsA response can contain the following information:Field Value DescriptionOption Bit 4=0 (0x0X) No Metadata flags are specified and Meta Data will not be returned. This is the Get Tag Data syntax. The lower bits (X) are specified as defined by Tag Singulation/Select Functionality.Bit 4=1 (0x1X) Indicates that Metadata flags are to follow and the corresponding Metadata shall be returned with the tag EPC. The lower bits (X) are specified as defined by Tag Singulation/Select Functional-ity.Metadata Flags (to specify more than one OR the values together)0x0000 When no flags are set no meta data will be returned, only the tag EPC (including PC bits and tag CRC)0x0001 When bit 0 is set the Read Count will be returned0x0002 When bit 1 is set the LQI/RSSI will be returned0x0004 When bit 2 is set the Antenna ID will be returned0x0008 When bit 3 is set the Frequency will be returned0x0010 When bit 4 is set the Timestamp will be returned0x0020 When bit 5 is set the RFU (ThingMagic Only) will be returned0x0040 When bit 6 is set the Protocol is returned.These fields are followed by the Read Tag Data Fields then the Tag Singulation/Select Func-tionality (set appropriate bits in the Option field defined above, do not specified an addi-tional Option field), used the same as defined in the Get Tag Data syntax, as necessary.
Gen2 Tag Commands122Read Tag Data Get Data and Metadata Response FieldsThe following example will attempt to read the Access Password (the first 2 words) from Reserved Memory. It will read this data from a tag matching the following criteria for a max timeout of 1000 ms.Memory Bank = EPC. Starting Address = bit 120 (beginning of the last byte of the EPC value: 16 PC bits + 16 CRC bits + 88 EPC bits)Select Data = 0x34Field Length ValueSOH 1 byte 0xFFLength 1 byte Based on data returnedOpCode 1 byte 0x21Options 1 byte As sent in requestMetadata Flags 2 bytes Metadata contained in responseRead Count11 byte Tag EPC/Antenna Read CountRSSI11 byte Return Signal Strength IndicatorAntenna ID11 byte Antenna ID, 4 MSBs for TX and 4 LSBs for RXFrequency13 bytes Frequency in kHzTimestamp14 bytes RTC TimestampRFU12 bytes Reserved for Future Use - ThingMagic OnlyProtocol ID 1 byte Protocol ID of tag readTag Data N bytes Request Tag Data.CRC 2 bytes Message CRC1 - Conditionally returned depending on the Metadata Fields specified in the request.
Gen2 Tag Commands123The Reserved Memory bank is not locked so the Access Password is zeroThe response to this Read Data command example is:Get Tag Buffer (29h)See Get Tag Buffer (29h) in Multi-Protocol Tag Commands.Clear Tag Buffer (2Ah)See Clear Tag Buffer (2Ah) in Multi-Protocol Tag Commands.Gen2 Tag Specific (2Dh)The Gen2 Tag Specific command is a generic command providing an interface for operations proprietary to certain Gen2 tag silicon. The supported commands are grouped by tag silicon type, indicated by the Chip Type field. Each Chip Type may have multiple unique commands associated with it, indicated by the Sub Command field.Alien Higgs Silicon (Chip Type=0x01)Tags with Alien Higgs Silicon support the following proprietary commands:FF 15 28 03   E8 14 00 14 00 00 00 00 02 02 00 00 00 00SOH Length OpCode Time-out (ms) Option Meta Data FlagsRead MemBank Read Address Word-Count Access Password00 00 00 78 08 34 9C 0ESelect Address Select Data LengthSelect Data CRCFF 0C 28 00 00 14 00 14 22 00 00 00 15 12 34 56 78 B2 B4SOH Length OpCode Status Option Meta Data Flags Antenna ID Timestamp Tag Read Data CRC
Gen2 Tag Commands124Alien Higgs Sub CommandsPartial Load Image Sub Command=0x01If the first bit of Sub Command is 1 (Sub Command=0x01), the Gen2 Tag Specific command writes an EPC with a length of up to 96-bits, plus the Kill and Access passwords without locking in a single command. The format for this command is as follows:Sub Command value Alien Higgs Command0x01 Partial Load Image0x03 Full Load ImageFF 18 2D 03 E8 01 01 00 00 00 00 00 00 00 00SOHLength OpCode Timeout (ms) Chip Type Sub Com-mandKill Password Access Password11 22 33 44 55 66 77 88 99 AA BB CC 45 64Tag ID CRC
Gen2 Tag Commands125Full Load Image Sub Command=0x03If the second bit of Sub Command is 1 (Sub Command=0x03), the Gen2 Tag Specific command will also modify the Lock bits (locking the tag according to the Alien Higgs Lock Bits) and the Alien Higgs PC Bits. The format is extended as follows:The Lock Bits correspond to the Higgs TID Bank configuration bits with the same name and are shown in the following table:Alien Higgs Lock BitsCurrently, only the first six bits of this field are used. A value of zero in each bit field keeps the corresponding memory segment unlocked. To lock any of the Kill and Access passwords or the EPC, temporarily or permanently, set the corresponding bit fields in the Lock Bits word to 1. For additional information, refer to the Higgs Tags Application Notes FF 1C 2D 03 E8 01 03 01 23 45 67 89 ABCDEFSOHLength OpCode Timeout (ms) Chip Type Sub Command Kill Password Access Password00 02 30 00 11 22 33 44 55 66 77 88 99 AA BBCC????Lock Bits PC Word Tag ID CRCBit Number 15 14 13 12 11 10 9 8 7 6Field Name> XXXXXX X X X XDefault Values XXXXXX X X X XLock Values XXXXXX X X X X5 43210APW LockAPW P-lockKPWLockKPWP-lockEPCLockEPCP-lock0 000001 11111
Gen2 Tag Commands126(Currently available at http://www.alientechnology.com/docs/Load_Image_Application_Note_1.pdf - Contact Alien Technology for more details).The PC Word field, in the table on the previous page, corresponds to the PC Word in the Tag EPC memBank defined in the Gen2 Specification and is shown in the following table:Alien Higgs PC BitsThe PC Word in the Write Tag Specific command allows you to specify the NSI Bits and the length of the EPC that you want to write into the tag. The RFU bits are always zero and the PC Bits are determined by the EPC length as specified in the Gen2 Specification and the Higgs Tags Application Notes. To use the extended format of the Gen2 Tag Specific command but keep the NSI bits intact, set option=0x03. This signals the reader to ignore the NSI bits of the PC Word sent to the reader along with the command.In the example on the previous page, after the execution of the Gen2 Tag Specific command, the reader writes the 96-bit EPC 0x112233445566778899AABBCC, the Kill Password 0x01234567, the Access Password 0x89ABCDEF into the tag without changing the NSI bits of the tag and locks the EPC memBank.However, to access and write the NSI bits into the tag, set the third bit of the option field to 1 (option=0x07). In the example, if option is set to 0x07, the NSI bits are overwritten by zeros.The following table summarizes the option field values and the action that is taken:Bit Number 15 14 13 12 11 10 9 8 7 6Field Name PC Bits RFU RFUDefault Values XXXXX0 0 00054 3 210NSI Bits00 0 000
Gen2 Tag Commands127NXP Silicon (Chip Type=0x02)Tags with NXP Silicon support the following proprietary commands as specified in the SL31CS1202 G2XM UCode Functional Specification (please contact NXP for details):NXP Sub CommandsAll NXP-proprietary commands contain the following fields:Bit Number210 Action0 0 0 Invalid Value001Gen2 Tag Specific without locking and without NSI bits being overwritten0 1 0 Invalid Value011Gen2 Tag Specific with locking and without NSI bits being overwritten1 0 0 Invalid Value101Gen2 Tag Specific without locking and with NSI bits being overwritten by zeros1 1 0 Invalid Value111Gen2 Tag Specific with locking and with NSI bits being overwritten by values that you specifySub Command value NXP Command0x01 Set ReadProtect0x02 Reset ReadProtect0x03 Change EAS0x04 EAS Alarm0x05 Calibrate
Gen2 Tag Commands128NXP Common FieldsIn addition to the common fields some commands have additional required fields as indicated below.Set ReadProtectThe NXP command Set ReadProtect causes the commands Read, Write, Kill, Lock, Access, Set ReadProtect, Change EAS, EAS Alarm and Calibrate to be disabled until a “Reset ReadProtect” is received. This command uses only the common fields and is invoked with the following command:The response to the Set ReadProtect command is a simple ACK with standard status:Field ValueLength 1 byteOpCode 0x2DTimeout 2 bytesOption 0x02 for NXPSub Command NXP Sub CommandsAccess Password 4 bytes, tag’s access passwordNote:  Must be non-zero for Set/Reset ReadProtect and Change EASNote:  EAS Alarm does not take the Access Password field.FF 08 2D 03 E8 02 01 12 34 56 78 ????SOHLength OpCode Timeout (ms) Chip Type Sub Com-mandAccess Password CRCFF 00 2D 00 00 1D 25SOH Length OpCode Status CRC
Gen2 Tag Commands129Reset ReadProtectThe NXP command Reset ReadProtect restores normal operation to a tag which is in ReadProtect mode. This command uses only the common fields and is invoked with the following command:The response to the Reset ReadProtect command is a simple ACK with standard status:Change EASThe NXP command Change EAS sets or resets the EAS system bit. When set, the tag will return an alarm code if an “EAS Alarm” command is received. This command takes an additional field:  Change EAS (1 byte: 0x01=Set EAS; 0x02=Reset EAS) It is invoked with the following command:The response to the Change EAS command is a simple ACK with standard status:EAS AlarmThe NXP command EAS Alarm causes the tag to return coded information, but only when the tag has its EAS system bit set. This command requires several fields in addition to the common fieldsFF 08 2D 03 E8 02 02 12 34 56 78 ????SOHLength OpCode Timeout (ms) Chip Type Sub Com-mandAccess Password CRCFF 00 2D 00 00 1D 25SOH Length OpCode Status CRCFF 09 2D 03 E8 02 03 00 00 00 00 00 ????SOHLength OpCode Timeout (ms) Chip Type Sub Com-mandAccess Password Change EAS CRCFF 00 2D 00 00 1D 25SOH Length OpCode Status CRC
Gen2 Tag Commands130 Divide Ratio as Per Gen2 (DR) (1 byte: Current fixed to 0x01, M5e and M5e-C only support DR=64/3) Miller Cycles (M) (1 byte: Current fixed to 0x02, M5e and M5e-C only support M=4) TrExt as Per Gen2 (1 byte: Current fixed to 0x01, M5e and M5e-C only support extended Pilot Tone)It is invoked with the following command:The response to the EAS Alarm command contains 8 bytes of EAS Alarm Data, only if Status=0x0000. The format of the response is:CalibrateThe NXP command Calibrate causes the tag to return a random data pattern that is useful in some frequency spectrum measurements. This command uses only the common fields and is invoked with the following command:The response to the Calibrate command contains 32 bytes of Calibrate Data, only if Status=0x0000. The format of the response is:FF 07 2D 03 E8 02 04 01 02 01 ????SOHLength OpCode Timeout (ms) Chip Type Sub Com-mandDR M TrExtCRCFF 0A 2D 00 00 02 04 [8 bytes] ?? ??SOH Length OpCode Status Chip Type Sub Com-mand[EAS Alarm Data] CRCFF 08 2D 03 E8 02 05 11 11 22 22 ????SOHLength OpCode Timeout (ms) Chip Type Sub Com-mandAccess Password CRCFF 42 2D 00 00 02 05 [64 bytes] ?? ??SOH Length OpCode Status Chip Type Sub Com-mand[Calibrate Data] CRC
Gen2 Tag Commands131NoteIf the tag is a G2XL without User Memory the Calibrate Data response field will contain 64 bytes of ‘00’.
Gen2 Tag Commands132Erase Block Tag Specific (2Eh)The Erase Block Tag Specific command is used for Tag specific block erases. The format for this command is as follows:Currently, the only acceptable Chip Type is 0x00 (indicates standard support of any tag supporting the Block Erase command as specified in the Gen2 Specification) and the only permissible option is 00 (Block Erase). The 32-bit Address field is the zero-based offset from the MemBank origin, in 16-bit words, where the contents of the tag memory will be erased. It corresponds to the WordPtr argument in the Gen2 command specification.The 8-bit MemBank field specifies which of the tag’s memory banks is to be addressed. It corresponds to the Gen2 argument of the same name. Its values are as mentioned for Write Tag Data command. Word Count specifies the number of 16-bit words to be erased. In the format example, data starting at word=0x02 (the third word) of EPC memory, which corresponds with the first word of the EPC ID, is erased .FF 0A 2E 03   E8 00 00 00 00 00 02 01 01 7B38SOH Length OpCode Timeout (ms) Chip Type Option Address Mem Bank Word Count CRC
Get Configuration Commands133Get Configuration CommandsThe Get commands listed in the following table are used to get settable parameters from the Mercury Embedded module. All of the commands have a data length of zero, and return data or a fault code. These commands cannot be run in the Bootloader. Get Configuration CommandsOpCode Command Name Arguments Return0x10 Get Hardware Version (10h) Option, Mask Hardware Information0x61 Get Antenna Configuration (61h) Option Antenna configuration0x62 Get Read TX Power (62h) Return Option (1 byte) Read TX Power Setting (and optionally Min. and Max power)0x63 Get Current Tag Protocol (63h) none Current Tag Protocol0x64 Get Write TX Power (64h) none Write TX Power Setting0x65 Get Frequency Hop Table (65h) none Current Frequency Hop Table0x66 Get User GPIO Inputs (66h) none GPIO Input Data0x67 Get Current Region (67h) none Current region being used0x68 Get Power Mode (68h) none Current power mode setting0x69 Get User Mode (69h) none Current user mode setting0x6A Get Reader Configuration(6Ah) none Current reader configuration options set0x6B Get Protocol Configuration (6Bh) Protocol, Parame-ter (2 bytes) Parameter Value0x6C Get Reader Statistics (6Ch) Option, Statistics Reader Statistics0x70 Get Available Protocols (70h) none Available Protocols0x71 Get Available Regions (71h) none Available regions.0x72 Get Current Temperature (72h) none Current module tempera-ture
Get Configuration Commands134Get Hardware Version (10h)The Get Hardware Version command is used to get information about the module it is executed on. Most of the information is not currently user-relavant but will often be required by ThingMagic Support to help diagnose problems.Get Hardware Version FieldsThe format of this command is:ExampleThe following command returns the FPGA TM and TC versions:The follow is an example response containing the FPGA TM and TC versions:Field Value DescriptionOption 0x00 Indicates the Data Flags will following specifying the information to be returned0x01 M6e-TC Only - Indicates the FPGA TM and TC versions should be returned. Note:  Do Not pass Data Flags when using Option=0x01.Data Flags 0x00 When no flags are set all data will be returned. FF 02 10 00 00 F0 93SOH Length OpCode Option Data Flags CRCFF 01 10 01 ?? ??SOH Length OpCode Option CRCFF 08 10 00 00 12 34 56 78 00 10 01 04 B9 5ESOH Length OpCode Status FPGA TM Version FPGA TC Version CRC
Get Configuration Commands135Get Antenna Configuration (61h)The Get Antenna Configuration command returns the current antenna configuration including which antennas are set to transmit and receive, and which ports have antennas attached.Reliable antenna detection requires that an attached antenna pass at least a small amount of DC current. Many antennas do not pass DC current. Due to such antennas an indication that a port is terminated is always accurate, but an indication that a port is not terminated may not be accurate.The format of the command is:The reply is formatted similar to the Set Antenna Port command. Data byte 01 returns the current TX antenna, and data byte 02 returns the current RX antenna. The default, and currently only, antenna configuration is TX on port #1 and RX on port #1. The Get Antenna Configuration command also includes an option that also returns information on which port(s) the antenna is connected.For example, a command is sent:The response returns the ports for TX and RX and also detects whether an antenna is connected to the port:FF 00 61 00 1D 6ESOH Length OpCode Option CRCFF 02 61 00 00 01 01 4E 21SOH Length OpCode Status TX Ant Num RX Ant Num CRCFF 01 61 01 1D 6ESOH Length OpCode Option CRC
Get Configuration Commands136Get Read TX Power (62h)The Get Read TX Power command returns the current TX power and, optionally, the minimum and maximum power levels supported by the module (and region setting) for reading tags, in centi-dBm.The option field allows you to specify what data you want returned:The following example gets the full set of power data:The example response contains the option specified followed by 2 byte fields for each power value: current = 0x0BB8 = 3000 centi-dBm = 30.00 dBmmax = 0x0BB8 = 3000 centi-dBm = 30. 00 dBmmin. = 0x01F4 = 500 centi-dBm = 5.00 dBmGet Current Tag Protocol (63h)The Get Current Tag Protocol command returns the currently set tag protocol(s). This is the protocol being used by the reader. The following table assigns a 16-bit code to each available protocol. This table will be updated as new protocols are added: FF 05 61 00 00 01 01 00 ?/ ??SOH Length OpCode Status TX Ant Num RX Ant Num Port 1Not Connected CRCOption Data returned0x00 Returns only the current TX power.0x01 Returns the current TX power and the maximum and minimum power levels for this module.FF 01 62 01 BE BCSOH Length OpCode Option CRCFF 07 62 00 00 01 0B B8 0B B8 01 F4 1F B7SOH Length OpCode Status Option Current centi-dBm Max centi-dBm Min centi-dBm CRC
Get Configuration Commands137Tag Protocol IDsThe command format is shown in the following example:NoteThe supported protocols vary depending on the hardware and firmware in use. The reply is similar to the Set Current Tag Protocol command. Only one protocol can be set at a time:Protocol Name 16-bit CodeNone Selected 0x0000EPC0 / EPC0+ Matrics 0x0001EPC1 0x0002ISO 18000-6B 0x0003EPC0+ Impinj 0x0004GEN2 0x0005UCODE 0x0006iPico 0x0007eGo 0x001BSeGo 0x001CATA 0x001DAllegro/Title-21 0x001EFF 00 63 1D 6CSOH Length OpCode CRCFF 02 63 00 00 00 1B ?? ??SOH Length OpCode Status Current Protocol CRC
Get Configuration Commands138Get Write TX Power (64h)The Get Write TX Power command returns the current TX power and, optionally, the minimum and maximum power levels supported by the module for reading tags, in centi-dBm.The option field allows you to specify what data you want returned:The following example gets the full set of power data:The example response contains the option specified followed by 2 byte fields for each power value: current = 0x0BB8 = 3000 centi-dBm = 30.00 dBmmax = 0x0BB8 = 3000 centi-dBm = 30.00 dBmmin. = 0x01F4 = 500centi-dBm = 5.00 dBmGet Frequency Hop Table (65h)The Get Frequency Hop Table command gets the current frequency hop table used in the Microprocessor:Option Data returned0x00 Returns only the current TX power.0x01 Returns the current TX power and the maximum and minimum power levels for this module.FF 01 64 01 B8 BCSOH Length OpCode Option CRCFF 07 64 00 00 01 0B B8 0B B8 01 F4 FF BCSOH Length OpCode Status Option Default centi-dBm Max centi-dBm Min centi-dBm CRC
Get Configuration Commands139The reply format is similar to the Set Frequency Hop Table command. The length must be set to a multiple of four, and a maximum of 62 hop frequencies is returned. The frequencies are returned in kHz. Thus, frequency #1 (0xDC370) corresponds to 902,000 kHz:Get User GPIO Inputs (66h)The Get User GPIO Inputs command returns the status of the User Input GPIO lines:The status of the GPIO lines is returned. Get Current Region (67h) The Get Current Region command gets the current region and, optionally, specific parameters for that region set in the reader. Currently available region codes are shown in the following table. Details on the Regulatory Compliance for each region can be found in Regional Support::FF 00 65 1D 6ASOH Length OpCode CRCFF 0C 65 00 00 00 0D C3 70 00 0D F6 38 00 0E 26 12 60 B2SOH Length OpCode Status Freq #1 Freq #2 Freq #3 CRCFF 00 66 1D 69SOH Length OpCode CRCFF 02 66 00 00 00 01 CA B2SOH Length OpCode Status Input #1 Input #2 CRC
Get Configuration Commands140Region codesTo get the current region send the following command:The command generates the following reply, which indicates that the reader is set to the NA region:Get Power Mode (68h) The Get Power Mode command returns the current Power Mode of the unit. The values for the available Power Modes are shown in the table.Available power modesRegion CodeNA 0x01Open 0xFFFF 00 67 1D 68SOH Length OpCode CRCFF 01 67 00 00 01 B4 80SOH Length OpCode Status Region CRCHex Power Mode0x00 Full power mode0x01 Minimal saving mode .0x02 Medium saving mode.0x03 Maximum saving mode.0x04-0xFF Reserved for future use.
Get Configuration Commands141NoteIf Set Power Mode (98h) is called using the USB interface and mode 0x03 is specified the module will instead be set to 0x02. In order to set the module to mode 0x03 the command must be called using the RS232 interface.The command gets the current power mode setting from the module:The example reply shows that the system is in the medium power saving mode:Get User Mode (69h)The Get User Mode command returns the type of application in which the M5e/M5e-Compact can be used. The available user modes are shown in the table:Available User ModesThe command gets the current user mode setting from the module:FF 00 68 1D 67SOH Length OpCode CRCFF 01 68 00 00 02 A4 BDSOH Length OpCode Status Power Mode CRCHex User Mode0x00 NONE (Default)0x01 PRINTER0x02 Unsupported0x03 PORTAL0x04 HAND HELD
Get Configuration Commands142The example reply shows the current user mode setting:Get Reader Configuration(6Ah)The Get Reader Configuration command returns the current reader configuration for the setting specified by the key field as defined in Set Reader Configuration(9Ah) when using Option=0x01. When using Option=0x00 it will use the previous format of the command.Send the following command to get the current PA Protection setting:The example reply shows the current configuration setting:Get Protocol Configuration (6Bh)The Get Protocol Configuration command is used to get current protocol-specific configuration parameters settings as specified in Set Protocol Configuration (9Bh).Send the following command to get the current Gen2 Session configuration parameter value:FF 00 69 1D 66SOH Length OpCode CRCFF 01 69 00 00 01 97 8FSOH Length OpCode Status User Mode CRCFF 02 6A 01 07 2E 49SOH Length OpCode Option Key CRCFF 03 6A 00 00 01 07 01 39 45SOH Length OpCode Status Option Key Value CRC
Get Configuration Commands143The example reply shows the Gen2 session is set to S2 (0x02):aGet Reader Statistics (6Ch)The Get Reader Statistics command allows the user to get and reset various statistics on the reader operation. The command takes the following fields:Get Reader Statistics Request FieldsFF 02 6B 05 00 3A 6FSOH Length OpCode Protocol Parameter CRCFF 03 6B 00 00 05 00 02 08 76SOH Length OpCode Status Protocol Parameter Value CRCField ValueOption (1 byte) •  0x00 - Get statistics specified by the Statistics Flag•  0x01 - Reset the specified statistic.Statistics Flag (1 byte) Each bit corresponds to a specific statistic to be returned. See the Avail-able Statistics table for bit values.
Get Configuration Commands144Available StatisticsThe response to a Get Reader Statistics command contains the following information:Statistics Flag Bit StatisticBit 0 (0x01) RF On Time (ms)- Indicates the aggregate time the transmitter has been on, in milliseconds, since the counter was last reset. Returned value contains 8 bytes (4 on the M5e-Compact), 4 bytes for each antenna. Note:  Clock rolls over every 232 milliseconds and must be taken into account by user application.Note:  Multiple statistics can be requested by a single command by performing a binary OR (setting each desired Statistics Flag bit to 1) on the desired flags and sending the result as the Statistics Flag byte.
Get Configuration Commands145Get Statistics Response FieldsTo request the RF On Time send the following command:The response, containing the RF On Time would look like:To reset the RF On Time statistic send the following command:Field DescriptionStatus (2 bytes) Standard response status Option (1 byte) Same as the Requested ValueRequested Statistics Flag (1 byte) Same as the Requested ValueFor each individual statistics requested as part of the Requested Statistics Flag the following fields will be repeated according to the Statistics Response value. They will be in bit value order.Statistic Flag (1 byte) The bit corresponding to the requested statistic.Data Length (1 byte) Indicates how many bytes are in this statistics response value.Statistics Response Value (N bytes as indicated by Data Length)The response value of the statistic as specified in Available StatisticsFF 02 6C 00 01 4F 89SOH Length OpCode Option Statistics Flag CRCFF 08 6C 00 00 00 01 01 04 00 00 08 4C D7 D9SOH Length OpCode Status Option Requested Stats Flag Stat Flag (RF On) Data Length Antenna1 RF On Time CRCFF 02 6C 01 01 4E 89SOH Length OpCode Option Statistics Flag CRC
Get Configuration Commands146Get Available Protocols (70h)The Get Available Protocols command returns the list of protocols that the reader is capable of reading. The protocol codes are defined in Get Current Tag Protocol (63h). The total number of protocols in the system cannot exceed 32. The command is generated as follows:The following Microprocessor response shows that the reader is capable of reading one protocol – GEN2:Get Available Regions (71h)The Get Available Regions command returns the list of regions that the reader is capable of working in. The total number of regions in the system cannot exceed 248. The list of region codes are found in Region codes. The command is generated as follows:The response shows that this reader is capable of reading in two regions – NA and Open:FF 00 70 1D 7FSOH Length OpCode CRCFF 02 70 00 00 00 05 3B 75SOH Length OpCode Status Protocol #1 CRCFF 00 71 1D 7ESOH Length OpCode CRCFF 02 71 00 00 01 FF ?? ??SOH Length OpCode Status Region#1 Region#2 CRC
Get Configuration Commands147Get Current Temperature (72h) The Get Current Temperature command returns the current board component temperature on the module in degrees Celsius as a signed 8-bit integer. This information can be used to determine if the module is exceeding its recommended operating temperature range. If the returned value exceeds the values specified in the table below an effort should be made to reduce the ambient temperature of the module or reduce the module’s duty cycle. The command is generated as follows:The response returns a signed 8-bit integer in degrees Celsius, 0x24 = 36oCModule Warning TemperatureM6e-TC 105°CFF 00 72 1D 7DSOH Length OpCode CRCFF 01 72 00 00 24 48 23SOH Length OpCode Status Temperature in Celsius CRC
Set Configuration Commands148Set Configuration CommandsThe Set commands are used to set configurable values in the firmware. Since the values are not stored in flash, these values are reset to the default values whenever the application firmware is restarted. These commands cannot be run in the Bootloader. The application responds with a fault code / ACK to all commands.The following table lists the Set commands:Set Configuration CommandsOpCode Command Name Arguments Return0x91 Set Antenna Port (91h) Antenna Port Selected none0x92 Set Read TX Power (92h) Read TX Power Setting none0x93 Set Current Tag Protocol (93h) Protocol ID none0x94 Set Write TX Power (94h) Power in centi-dBm none0x95 Set Frequency Hop Table (95h) Table of hop frequencies in kHz none0x96 Set User GPIO Outputs (96h) GPIO output states none0x97 Set Current Region (97h) Region Codes, LBT  none0x98 Set Power Mode (98h) PowerMode Enums, Timeout (ms) none0x99 Set User Mode (99h) UserMode Enums, Timeout (ms) none0x9A Set Reader Configuration(9Ah) Reader Configuration Options (bitwise) none0x9B Set Protocol Configuration (9Bh) Protocol, Parameter, Value (3 bytes) none
Set Configuration Commands149Set Antenna Port (91h)The Set Antenna Port command sets the antenna port to the number specified. The transmitter and receiver ports are specified, currently on port 0x01 is supported on the M6e-TC. Each antenna port is an 8-bit value set up as a bit mask. Thus, only one of the eight bits should be set at a time. The example below sets both antennas to bit mask 0x01, which would correspond to the first antenna in the system.Valid settings for this command are:TX = 1 RX = 1All other settings will result in an error.Set Read TX Power (92h)The Set Read TX Power command sets the power level to be used for reading tags. The power is specified as a 16-bit value in centi-dBm. For instance, a power of 25 dBm is 2500 centi-dBm, which is 0x09C4.FF 02 91 01 01 70 3BSOH Length OpCode TX Ant Num Rx Ant Num CRCFF 02 92 09 C4 48 9DSOH Length OpCode Power in centi-dBm CRC
Set Configuration Commands150Set Current Tag Protocol (93h)To select a protocol, send the Set Current Tag Protocol code to the reader. A table of valid protocol codes is found in Get Current Tag Protocol (63h). The following example sets the protocol to GEN2:Only protocols that are enabled in the reader are available. These protocols are listed in the version information for the application, described in Get Boot Loader/Firmware Version (03h).Set Write TX Power (94h)The Set Write TX Power command sets the power level to use for writing to tags. This is necessary because a write operation may require a different RF power setting than a read command. The format and arguments of this command are identical to the Set Read TX Power command:Set Frequency Hop Table (95h)The Set Frequency Hop Table command sets the list of frequencies to use when hopping. Each frequency is encoded as a 32-bit value in kHz. For instance, 915MHz is encoded as 915000kHz, which is 0x000DF638. The maximum number of hop frequencies is 62, since that is the maximum number of 32-bit values that can be sent using a message packet. If fewer values are used, only those values are populated in the table and the rest of the slots are ignored. FF 02 93 00 05 51 7DSOH Length OpCode Current Protocol CRCFF 02 94 09 C4 28 5BSOH Length OpCode Power in centi-dBm CRC
Set Configuration Commands151NoteThe data length of this message encodes the number of frequencies to populate into the hop table. The length must be divisible by four for the message to be properly formatted.This example shows a command that sets up a table with only three values:The generated hop table has values of 902MHz, 915MHz, and 927.25MHz. For the US region, valid frequencies are 902MHz – 928MHz. If any of the values in the table are invalid, then none of the values are recorded. The Set Frequency Hop Table command should be used for debug only, as there should be no reason to modify the frequency hop table in the field. Set User GPIO Outputs (96h)There are two GPIO outputs available for use. The Set User GPIO Outputs command has been “overloaded” to create a mechanism to return the current state of both GPIO pins. To set either GPIO Output pin, send the following command. Note that the data length is 2 bytes:FF 0C 95 00 0D C3 70 00 0D F6 38 00 0E 26 12 C1 8FSOH Length OpCode Freq #1 Freq #2 Freq #3 CRCCAUTION!!!Any changes to the frequency hop tablecould put you out of compliance with theLocal Regulatory Requirements (for exam-ple, FCC, ETSI, MIC).FF 02 96 01 01 28 E0SOH Length OpCode GPIO # Output Value CRC
Set Configuration Commands152This example sets the GPIO Output #1 to ‘1’ (high). To get the current status of the GPIO output pins, send the same command, with the length set to 0:The response looks similar to the Get User GPIO Inputs command:Set Current Region (97h)The Set Current Region command sets the current region for use in the reader. The list of region codes are found in Region codes. See Regional Support for more information on regional functionality.Setting the region performs the following:1.    Frequency hop table is set to the default for the region.2.    Any other region specific settings are set (i.e. LBT) to default values unless otherwise specified. Currently only LBT is configurable for regions supporting it.The Set Current Region command supports two command syntaxes:  The basic syntax for all regions where only the region code is specified. For example, to set the region to KR: The extended syntax allowing the region code plus LBT Enabled (if supported by Region) to be set. For example, to set the Region to EU3 and Enable LBT:FF 00 96 1D 99SOH Length OpCode CRCFF 02 96 00 00 00 01 29 E0SOH Length OpCode Status Output #1 Output #2 CRCFF 01 97 03 4B BESOH Length OpCode Region CRCFF 02 97 08 01 19 FDSOH Length OpCode Region LBT Enable CRC
Set Configuration Commands153NoteWhen LBT is disabled in the Open region the M6e-TC will implement frequency hopping as implemented for the NA region with a frequency hop interval of 400ms.Set Power Mode (98h)The Set Power Mode command can set the M6e-TC to four different power management modes. See Available power modes. Use the Set Power Mode command to set the power mode to maximum saving mode by sending the following:Set User Mode (99h) Use the Set User Mode command to set the user mode to the type of application in which the M6e-TC will be configured for the optimal Search Strategy settings for a particular protocol. Send the following to set the user mode to printer:The list of user modes and their corresponding session are found in Available User Modes. Setting the User Mode to an unsupported value will not modify the current setting.Set Reader Configuration(9Ah)The Set Reader Configuration command is used to set several configuration options on the reader. The Option byte indicates whether to use the new key/value pair setting or the previous, bitwise, settings. One example configuration and the corresponding Options value is specified in the command example below. For other combinations the hex value for Options will need to be calculated by OR’ing the bits for each setting.FF 01 98 03 44 BESOH Length OpCode Power Mode CRCFF 01 99 01 45 BCSOH Length OpCode User Mode CRC
Set Configuration Commands154Available Configuration OptionsSend the following to enable the 496 bit EPC mode:NoteMultiple settings cannot be applied in a single command.Set Protocol Configuration (9Bh)The Set Protocol Configuration command is used to set protocol-specific configuration parameters. The table below defines the currently available protocol-specific parameters which can be set and the supported settings. Additional parameters will be supported in the future.Option Key Value Reader Configuration setting0x00 Indicates the deprecated format of this command will be used.0x01 Maximum EPC Length = 0x02 0x00 Maximum EPC length of 96 bits (Default)0x01 Maximum EPC length of 496 bitsRecord the highest RSSI seen= 0x060x00 The RSSI Tag Read Meta Data value is the value for the last read tag for each tag buffer entry when this is Dis-abled. (Default)0x01 When Enabled the RSSI Tag Read Meta Data value will be the highest value recorded during the Read Tag Multi-ple (22h) search operation.PA Protection= 0x07 0x00 Disable - Turns off Power Amplifier Protection. NOT RECOMMENDED.0x01 Enable (Default)Tag Data as Unique Iden-tifier of Tag Buffer entry. = 0x080x00 Tag Data is a unique characteristic of a Tag Buffer Entry.0x01 Tag Data is ignored for Tag Buffer Entry uniqueness (Default)FF 03 9A 01 02 01 AD 5CSOH Length OpCode Option Key Value CRC
Set Configuration Commands155Protocol Configuration SettingsNoteSetting the parameters using Set Protocol Configuration will override the implicit value set by a previous call to Set User Mode. Likewise, a subsequent call to Set User Mode will override the parameters set by Set Protocol Configuration. Get Protocol Configuration will always return the current setting regardless of whether it was set by Set Protocol Configuration or Set User Mode.Set Gen2 SessionThe following example sets the Gen2 session to S2:aProtocol Value Parameter Option Value0x05 (Gen2) Gen2 Session used for Inventory commands. (0x00)N/A 0x00 (S0 - Default)0x01 (S1)0x02 (S2)0x03 (S3)Gen2 Q Value (0x12)Dynamic (0x00) - Automatically adjust Q value. N/AStatic (0x01) - User specified Q Value between 0 and 15.1 byte (0x00-0x0F)0x1B (eGo) n/a0x1C (SeGo) n/a0x1D (ATA) n/a0x1E(Allegro/Title-21) n/aFF 03 9B 05 00 02 DC EASOH Length OpCode Protocol Parameter Value CRC
Set Configuration Commands156Set Q ValueThe Q valued can be set to a static user specified value or to dynamically change based on ThingMagic internal algorithms. When using the dynamic Q setting the Value parameter is dropped in the command. The following example statically sets the Q value to 6:The following example sets dynamic Q value adjusting:FF 04 9B 05 12 01 06 80 A9SOH Length OpCode Protocol Parameter Option Value CRCFF 03 9B 05 12 00 CE E8SOH Length OpCode Protocol Parameter Option CRC
FCC Test Commands157FCC Test CommandsThe following OpCodes are used for test purposes including regulatory certification testing. These commands cannot be run in the Bootloader. NoteSet Power Mode to Full 0x00 before running FCC commands.FCC Test CommandsOpCode Command Name Arguments Return BL App0xC1 Set Operating Frequency (C1h)Frequency in kHz none N Y0xC3 Transmit CW Signal (C3h) CW mode, [tim-eout] none N Y
FCC Test Commands158Set Operating Frequency (C1h)The Set Operating Frequency command takes a 32-bit frequency value, expressed in kHz. For instance, to set the frequency to 915.26MHz, send the data value 915260 (0x000D F73C) to the reader. Transmit CW Signal (C3h)The Transmit CW Signal command turns the Continuous Wave (CW) signal On or Off or enables a PRBS signal. Sending 0x00 turns Off the CW signal; sending 0x01 turns On the CW signal; Sending 0x02 turns on a PRBS signal. The CW signal is transmitted at the last used power level. This example shuts off CW:Some regulatory testing requires a PRBS (Pseudo-Random Bit Sequence) signal to simulate data transmission. To send a PRBS signal, along with sending CW=0x02, the Length field must be changed to 0x03. This indicates PRBS will be used and an extra 2 byte Timeout field must be added. When this PRBS mode is used the CW signal is on until the timeout expires, during that period the reader does not respond to commands.The following example generates a PRBS CW signal for 256 ms, 100% duty cycle:FF 04 C1 00 0D F7 3C F3 B7SOH Length OpCode Freq to Set CRCFF 01 C3 00 1F BDSOH Length OpCode CW CRCFF 03 C3 02 01 00 01 00SOH Length OpCode CW/PRBS Timeout CRC
FCC Test Commands159Get Operating Frequency (C8h)The Get Operating Frequency command returns the currently operating frequency, as set by Set Operating Frequency (C1h) for testing. The operating frequency is returned as a 32-bit value, expressed in kHz. For instance, for the frequency 915.26MHz, the value 0x000D F73C will be returned. FF 00 C1 1D C7SOH Length OpCode CRC
FCC Test Commands160
Appendix A: Hardware Details  161 Appendix A: Hardware DetailsThis Appendix details the mechanicals for the M6e-TC including the pin 1 location for the serial connector.MechanicalsThe following figures detail the hardware layout of the M6e-TC Module.
Mechanicals162 Appendix A: Hardware DetailsM6e-TC MechanicalsAntenna ConnectorThe M6e-TC has one MMCX connector for interfacing to the antenna.
MechanicalsAppendix A: Hardware Details 163Communications ConnectorThe communications interface on the module provides power, serial communications signals, and access to the GPIO inputs and outputs.The M6e-TC has a 14-pin connector. For the interface pin-out, see M6e-TC Digital Connectors.The following figure shows a diagram of the M6e-TC communications interface as you face the boards.ConnectorsThe connectors used for the communications interface on the M6e-TC are as follows: JST SM14B-SRSS-TBMating Connector: Connector Shell: JST SHR-14V-S-B Crimp Contacts: JST SSH-003T-PO.2-HPin 1M6e-TCDigital ConnectorAntenna Port
Mechanicals164 Appendix A: Hardware Details
Appendix B: Using the ArbSer Application  165 Appendix B: Using the ArbSer ApplicationThis appendix explains how to use the ArbSer application. This application provides some simple commands for using the Mercury embedded modules to read tags. The ArbSer program is a simple terminal program with which you can communicate with the M4e, M5e, M5e-C, and M6e-TC modules. It provides several pre-formed commands, as well as a raw message interface that can be used to generate any command. The source code is part of the developer’s kit to provide an example of the message format and CRC calculation.The executable was built using a Windows 2000 PC. If the host PC’s operating system is different, the executable should be rebuilt using Microsoft Visual C++ 6.0, or other compatible compiler. If building ArbSer on another platform, some work may be necessary to integrate the serial port properly.ArbSer provides a help message if it is called with no argument:C:\> ArbSerArbSer Version 3.2.0.Usage: ArbSer <baud> <COM port> <option>Default baud rate is 9600. To use 115200: ArbSer 115200 <options>Default COM port is COM1. To use COM3:   ArbSer <baud> -c3 <options>Only one option can be used at a time:-eraseApp – Erase application FW only (sectors 1-8).-genMsg – Generates a msg and prints it to console.-go – Start the application FW.-l5a MercuryE – Load the application FW into FLASH-l5f x.dat <addr> – Load Program file x.dat at FLASH address <addr>
166 Appendix B: Using the ArbSer Application-msg xx xx xx ... – Send properly formatted msg (appends SOH and CRC).-raw xx xx xx ... – Send raw hexadecimal msg (illegal msgs possible).-ver – Returns the version information.When using ArbSer, the serial port and baud rate can be changed from the default of COM1 and 9600 bps. Then, one of the options must be selected. The most useful ones are ‘-go’, ‘-msg’, and ‘-ver’. These commands provide the ability to exercise every feature of the modules.Reading a TagNow that the module is connected to the PC and is powered on, the ArbSer.exe program is used to communicate with it. Send the sequence of commands described in this section. The raw hexadecimal output sent through the serial port is shown following the ArbSer command. This is an example of the exact serial traffic sent to the Microprocessor.
Appendix B: Using the ArbSer Application 167Get Version CommandWhen the unit is first powered up, the boot loader is running. Verify that the module is alive by sending a Get Version command:C:\> ArbSer –ver< Equivalent to: FF 00 03 1D 0c >Valid message received: Data Length = 14 OpCode   = 03 Status   = 00 00 Data[000]  = 03 Data[001]  = 01 Data[002]  = 00 Data[003]  = 05 Data[004]  = FF Data[005]  = FF Data[006]  = FF Data[007]  = FF Data[008]  = 20 Data[009]  = 04 Data[010]  = 11 Data[011]  = 03 Data[012]  = 03 Data[013]  = 01 Data[014]  = 00 Data[015]  = 06 Data[016]  = 00
168 Appendix B: Using the ArbSer Application Data[017]  = 00 Data[018]  = 00 Data[019]  = 07 CRC     = 42EAThe module returns its version information. In the previous example, the version number shows the following: Boot loader version #3.1.5 Application FW build date: 11/03/2004 Application FW version #3.1.6 3 protocols enabled (EPC0, EPC1, ISO18000-6B).Boot Firmware CommandNext, send a Boot Firmware command:C:\> ArbSer –go< Equivalent to: FF 00 04 1D 0B >
Appendix B: Using the ArbSer Application 169Valid message received: Data Length = 14 OpCode   = 04 Status   = 00 00 Data[000]  = 03 Data[001]  = 01 Data[002]  = 00 Data[003]  = 05 Data[004]  = FF Data[005]  = FF Data[006]  = FF Data[007]  = FF Data[008]  = 20 Data[009]  = 04 Data[010]  = 11 Data[011]  = 03 Data[012]  = 03 Data[013]  = 01 Data[014]  = 00 Data[015]  = 06 Data[016]  = 00 Data[017]  = 00 Data[018]  = 00 Data[019]  = 07 CRC     = 4B6A
170 Appendix B: Using the ArbSer ApplicationThis returns the same version information as the -ver command previously documented. Now that the application FW has been started, the reader is ready to accept protocol commands. To read an EPC0 tag, place the tag about one foot away from the antenna. Then send the following series of commands.Set Current Region CommandBefore you can start reading tags with the M5e, M5e-C and M6e-TC, you must set the region in which the reader resides.For example, if the region is the European Union, using the Set Current Region command, set the region as follows:C:\> ArbSer –msg 01 97 02<Equivalent to: FF 01 97 02 4B BE>Valid message received:Data Length = 00OpCode = 93Status = 00 00CRC = 371A
Appendix B: Using the ArbSer Application 171Set Current Tag Protocol CommandWhen the application FW first starts, there is no default protocol loaded. Thus, the protocol to use must be specified. For this example, the protocol is set to EPC0 using the Set Current Tag Protocol command:C:\> ArbSer –msg 02 93 00 01< Equivalent to: FF 02 93 00 01 51 79 >Valid message received: Data Length = 00 OpCode   = 93 Status   = 00 00 CRC     = 371ASet Read TX Power CommandThe default read power setting for the modules is 26.5 dBm. This should be adequate to read the tag from 1 foot. If a different power setting is desired, it should be entered now. The following Set Read TX Power command sets the power level to 25.0 dBm (0x09C4):C:\> ArbSer –msg 02 92 09 C4< Equivalent to: FF 02 92 09 C4 FC E5 >Valid message received: Data Length = 00 OpCode   = 92 Status   = 00 00 CRC     = 273BSet Antenna Port CommandThe default antenna port configuration is a 2-port antenna, with TX on port 1 and RX on port 2. If a different configuration is being used, it should be changed before attempting to
172 Appendix B: Using the ArbSer Applicationread tags. For example, to use a one-port configuration that uses only port 1, use the Set Antenna Port command:C:\> ArbSer –msg 02 91 01 01< Equivalent to: FF 02 91 01 01 70 3B >Valid message received: Data Length = 00 OpCode   = 91 Status   = 00 00 CRC     = 1758Finally, the module is ready to execute a read command. The timeout for the read can be set anywhere from 0 ms to 65,536 ms. Using the Read Single Tag ID command, the timeout is set to 1 s, which is 1000 ms (0x03E8):
Appendix B: Using the ArbSer Application 173C:\> ArbSer –msg 02 21 03 E8< Equivalent to: FF 02 21 03 E8 D5 09 >Valid message received: Data Length = 0E OpCode   = 21 Status   = 00 00 Data[000]  = 12 Data[001]  = 34 Data[002]  = 56 Data[003]  = 78 Data[004]  = 9A Data[005]  = BC Data[006]  = DE Data[007]  = F0 Data[008]  = AA Data[009]  = BB Data[010]  = CC Data[011]  = DD Data[012]  = 23 Data[013]  = 79 CRC     = 2384The module should now return the tag ID of the tag. In this example, the 96-bit EPC0 tag ID is (0x12 34 56 78 9A BC DE F0 AA BB CC DD) with a tag ID CRC of 0x2379.
174 Appendix B: Using the ArbSer ApplicationUnexpected ResultsSometimes you do not get the results that you expected. The following sections explain some problems that can occur when the previously listed sequence of commands are used. The following sections explain some of the frequently encountered errors.Serial Communication Does Not WorkIf serial communications fails to work using the ArbSer command, check the following: The baud rate is correct.  If the baud rate of the boot loader or application FW was changed, then specify the current baud rate using ArbSer. For example, “ArbSer <baudrate> ...”. The correct COM port is being used.  ArbSer does not return an error if it is able to open the specified COM port. Currently, ArbSer works on COM1 to COM9. The commands are properly formed.  If no SOF byte (0xFF) is used, or an incorrect CRC or number of data elements is specified, then the Microprocessor does not respond to the message at all.  The module is properly connected and powered on.  The serial cable should not be a NULL modem cable. The PC serial port is working properly. An RS-232 line checker is helpful for this.A simple way to check that serial communications is working is to try sending a Get Version command. If a valid response is received, then the physical communication layer is intact and working properly. That is to say that the baud rate, COM port, and cables are all fine.Commands Return a Non-Zero Status CodeIf a command returns a non-zero status code, this is not always an error. However, if a non-zero code is received in response to a Set command, such as Set Current Tag Protocol, Set Read TX Power, or Set Antenna Port commands, it is likely that one of the following problems exists: The module is still executing the boot loader program.
Appendix B: Using the ArbSer Application 175Send a Boot Firmware command to verify that the application FW is running. If the boot loader is currently running, then a set command will return a 0x0101 status code, indicating an invalid OpCode. The parameter(s) to the set command are invalid. If an invalid parameter is sent, then a 0x0105 status code is returned, indicating an invalid parameter value. If the wrong number of data elements is used, then a 0x0100 status code (wrong number of data) is returned. This could be the result of an ill-formed command, or accidentally using the wrong OpCode.No Tag ID is Returned If the Read Tag ID Single command returns an error code of 0x0400 (no tag found), then most likely it is a set up related issue. Check the following items: The antenna is properly connected to the unit and configured using the Set Antenna Port command. The tag is the right protocol (that is EPC0) and that the protocol has been set using the Set Current Tag Protocol command. Try using a longer timeout, such as 30 seconds, and varying the tag’s location in relation to the antenna. It is also possible the tag may be erased or damaged. Without a second “known good” reader, it is difficult to tell if this is the case. If a “known good” tag is available, try to read it.
176 Appendix B: Using the ArbSer Application
Appendix C: Error Messages  177 Appendix C: Error MessagesThe following error codes were incorporated into the reader for help in locating errors.Common Error MessagesThe following table lists the common faults discussed in this section.FAULT_MSG_WRONG_NUMBER_OF_DATA – (100h)CauseIf the data length in any of the Host-to-M5e/M5e-Compact messages is less than or more than the number of arguments in the message, the reader returns this message.Fault Message CodeFAULT_MSG_WRONG_NUMBER_OF_DATA – (100h) 100hFAULT_INVALID_OPCODE – (101h) 101hFAULT_UNIMPLEMENTED_OPCODE – 102h 102hFAULT_MSG_POWER_TOO_HIGH – 103h 103hFAULT_MSG_INVALID_FREQ_RECEIVED (104h) 104hFAULT_MSG_INVALID_PARAMETER_VALUE - (105h) 105hFAULT_MSG_POWER_TOO_LOW - (106h) 106hFAULT_UNIMPLEMENTED_FEATURE - (109h) 109hFAULT_INVALID_BAUD_RATE - (10Ah) 10Ah
Common Error Messages178 Appendix C: Error MessagesSolutionMake sure the number of arguments matches the data length.FAULT_INVALID_OPCODE – (101h)CauseThe opCode received is invalid or not supported with the current version of code.SolutionCheck the documentation for the opCode the host sent and make sure it is supported.FAULT_UNIMPLEMENTED_OPCODE – 102hCauseSome of the reserved commands might return this error code.  This does not mean that they always will do this since ThingMagic reserves the right to modify those commands at anytime. SolutionCheck the documentation for the opCode the host sent to the reader and make sure it is supported.FAULT_MSG_POWER_TOO_HIGH – 103hCauseA message was sent to set the read or write power to a level that is higher than the current HW supports.
Common Error MessagesAppendix C: Error Messages 179SolutionCheck the HW specifications for the supported powers and insure that the level is not exceeded. The M5e 1 Watt units support power from 5 dBm to 30 dBm.The M5e-Compact units support power from 10 dBm to 23 dBm.FAULT_MSG_INVALID_FREQ_RECEIVED (104h)CauseA message was received by the reader to set the frequency outside the supported rangeSolutionMake sure the host does not set the frequency outside this range or any other locally supported ranges.FAULT_MSG_INVALID_PARAMETER_VALUE - (105h)CauseThe reader received a valid command with an unsupported or invalid value within this command. For example, currently the module supports two antennas, 1 and 2. If the module receives a message with an antenna value other than 1 or 2, it returns this error.SolutionMake sure the host sets all the values in a command according to the values published in this document.FAULT_MSG_POWER_TOO_LOW - (106h)CauseA message was received to set the read or write power to a level that is lower than the current HW supports.
Common Error Messages180 Appendix C: Error MessagesSolutionCheck the HW specifications for the supported powers and insure that level is not exceeded. The M5e supports powers between 5 and 30 dBm. The M5e-Compact units support power from 10 dBm to 23 dBm.FAULT_UNIMPLEMENTED_FEATURE - (109h)CauseAttempting to invoke a command not supported on this firmware or hardware.SolutionCheck the command being invoked against the documentation.FAULT_INVALID_BAUD_RATE - (10Ah)CauseWhen a Set Baud Rate (0x06h) command is issued for a rate that is not specified in the Baud Rate table, this error message is returned. SolutionCheck the table of specific baud rates and select a baud rate. Send the baud rate in the hex format. See Set Baud Rate (06h).
Bootloader FaultsAppendix C: Error Messages 181Bootloader FaultsThe following table lists the common faults discussed in this section.FAULT_BL_INVALID_IMAGE_CRC – 200hCauseWhen a Verify Image CRC (0x08), or Boot Firmware (0x02) command is issued, the reader checks the image stored in flash and returns this error if the calculated CRC is different than the one stored in flash.SolutionThe exact reason for the corruption could be that the image loaded in flash was corrupted during the transfer or corrupted for some other reason. To fix this problem, reload the application code in flash.FAULT_BL_INVALID_APP_END_ADDR – 201hCauseWhen a Verify Image CRC (0x08), or Boot Firmware (0x02) command is issued, the reader checks the image stored in flash and returns this error if the last word stored in flash does not have the correct address value.SolutionThe exact reason for the corruption could be that the image loaded in flash got corrupted during the transfer or, corrupted for some other reason. To fix this problem, reload the application code in flash.Fault Message CodeFAULT_BL_INVALID_IMAGE_CRC 200hFAULT_BL_INVALID_APP_END_ADDR 201h
FPGA Faults182 Appendix C: Error MessagesFPGA FaultsThe following table lists the common faults discussed in this section.FAULT_PROGRAM_ERASE_FAILED – 2E0hCauseWhen a boot firmware (0x02) is issued during an FPGA image load and the erase of the FPGA FlashROM pages failsSolutionPower cycle the module and reload the FPGA load application and FPGA image. If problem persists try a previous version of the FPGA Loag Image application with the same DAT file.FAULT_PROGRAM_FAILED – 2E1hCauseWhen a boot firmware (0x02) is issued during an FPGA image load and the programming of the FPGA FlashROM pages fails.SolutionPower cycle the module and reload the FPGA load application and FPGA image. If problem persists try a previous version of the FPGA Loag Image application with the same DAT file.Fault Message CodeFAULT_PROGRAM_ERASE_FAILED – 2E0h 2E0hFAULT_PROGRAM_FAILED – 2E1h 2E1hFAULT_PROGRAM_VERIFY_FAILED – 2E2h 2E2hFAULT_PROGRAM_OPERATION_FAILED – 2E3h 2E3hFAULT_PROGRAM_NOT_LOADED – 2E4h 2E4h
FPGA FaultsAppendix C: Error Messages 183FAULT_PROGRAM_VERIFY_FAILED – 2E2hCauseWhen a boot firmware (0x02) is issued during an FPGA image load and the verification of the FPGA FlashROM pages fails.SolutionPower cycle the module and reload the FPGA load application and FPGA image. If problem persists try a previous version of the FPGA Load Image application with the same DAT file.FAULT_PROGRAM_OPERATION_FAILED – 2E3hCauseWhen a boot firmware (0x02) is issued after the FPGA image is loaded and the verification of the FPGA version and testing of the 16-bit FPGA-ATMEL parallel interface fails.SolutionPower cycle the module and reload the FPGA load application and FPGA image. Check that the FPGA TM and TC version numbers start with 0x1234xxxx and 0x0010, respectively. If problem persists contact support@thingmagic.com.FAULT_PROGRAM_NOT_LOADED – 2E4hCauseWhen a boot firmware (0x02) is issued and the FPGA DAT file has not been loaded.SolutionPower cycle the module and reload the FPGA load application and FPGA image. If problem persists try a previous version of the FPGA Load Image application with the same DAT file.
Flash Faults184 Appendix C: Error MessagesFlash FaultsThe following table lists the common faults discussed in this section.FAULT_FLASH_BAD_ERASE_PASSWORD – 300hCauseA command was received to erase some part of the flash but the password supplied with the command was incorrect.SolutionMake sure that you have the correct password for the flash sector. Go to the Erase Flash Sector (07h) section for more information about the flash passwords and sectors.FAULT_FLASH_BAD_WRITE_PASSWORD – 301hCauseA command was received to write some part of the flash but the password supplied with the command was not correct.Fault Message CodeFAULT_FLASH_BAD_ERASE_PASSWORD – 300h 300hFAULT_FLASH_BAD_WRITE_PASSWORD – 301h 301hFAULT_FLASH_UNDEFINED_ERROR – 302h 302hFAULT_FLASH_ILLEGAL_SECTOR – 303h 303hFAULT_FLASH_WRITE_TO_NON_ERASED_AREA – 304h 304hFAULT_FLASH_WRITE_TO_ILLEGAL_SECTOR – 305h 305hFAULT_FLASH_VERIFY_FAILED – 306h 306h
Flash FaultsAppendix C: Error Messages 185SolutionMake sure that you have the correct password for the flash sector. Check the Write Flash Sector (0Dh) for more information about the flash passwords and sectors.FAULT_FLASH_UNDEFINED_ERROR – 302hCauseThis is an internal error and it is caused by a software problem in module.SolutionContact support at support@thingmagic.com.FAULT_FLASH_ILLEGAL_SECTOR – 303hCauseAn erase or write flash command was received with the sector value and password not matching.SolutionMake sure that you have the correct password for the flash sector. Go to Accessing the Flash for more information about the flash passwords and sectors.FAULT_FLASH_WRITE_TO_NON_ERASED_AREA – 304hCauseThe module received a write flash command to an area of flash that was not previously erased.SolutionErase that sector of flash and then, try and rewrite to it.
Flash Faults186 Appendix C: Error MessagesFAULT_FLASH_WRITE_TO_ILLEGAL_SECTOR – 305hCauseThe module received a write flash command to write across a sector boundary that is prohibited.SolutionIf the data spans two sectors, separate the data into two messages.FAULT_FLASH_VERIFY_FAILED – 306hCauseThe module received a write flash command that was unsuccessful because data being written to flash contained an uneven number of bytes.SolutionVerify that the data being sent is an even number of bytes.
Protocol FaultsAppendix C: Error Messages 187Protocol FaultsThe following table lists the common faults discussed in this section.Fault Message CodeFAULT_NO_TAGS_FOUND – (400h) 400hFAULT_NO_PROTOCOL_DEFINED – 401h 401hFAULT_INVALID_PROTOCOL_SPECIFIED – 402h 402hFAULT_WRITE_PASSED_LOCK_FAILED – 403h 403hFAULT_PROTOCOL_NO_DATA_READ – 404h 404hFAULT_AFE_NOT_ON – 405h 405hFAULT_PROTOCOL_WRITE_FAILED – 406h 406hFAULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407h 407hFAULT_PROTOCOL_INVALID_WRITE_DATA – 408h 408hFAULT_PROTOCOL_INVALID_ADDRESS – 409h 409hFAULT_GENERAL_TAG_ERROR – 40Ah 40AhFAULT_DATA_TOO_LARGE – 40Bh 40BhFAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch 40ChFAULT_PROTOCOL_KILL_FAILED - 40Eh 40EhFAULT_PROTOCOL_BIT_DECODING_FAILED - 40Fh 40FhFAULT_PROTOCOL_INVALID_EPC – 410h 410hFAULT_PROTOCOL_INVALID_NUM_DATA – 411h 411hFAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h 420hFAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC - 423h423hFAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h 424hFAULT_GEN2 PROTOCOL_INSUFFICIENT_POWER - 42Bh 42BhFAULT_GEN2 PROTOCOL_NON_SPECIFIC_ERROR - 42Fh 42FhFAULT_GEN2 PROTOCOL_UNKNOWN_ERROR - 430h 430h
Protocol Faults188 Appendix C: Error MessagesFAULT_NO_TAGS_FOUND – (400h)CauseA command was received (such as like read, write, or lock) but the operation failed. There are many reasons that can cause this error to occur. Here is a list of possible reasons that could be causing this error:  No tag in the RF field Read/write power too low Antenna not connected Tag is weak or deadSolutionMake sure there is a good tag in the field and all parameters are set up correctly. The best way to check this is to try few tags of the same type to rule out a weak tag. If none passed, then it could be SW configuration such as protocol value, antenna, and so forth, or a placement configuration like a tag location.FAULT_NO_PROTOCOL_DEFINED – 401hCauseA command was received to perform a protocol command but no protocol was initially set. The reader powers up with no protocols set.SolutionA Set Current Tag Protocol (63h) command must be sent followed by resending the desired command.FAULT_INVALID_PROTOCOL_SPECIFIED – 402hCauseA Set Current Tag Protocol (63h) command was received for a protocol value that is not supported with the current version of SW.
Protocol FaultsAppendix C: Error Messages 189SolutionThis value is invalid or this version of SW does not support the protocol value. Check the documentation for the correct values for the protocols in use.FAULT_WRITE_PASSED_LOCK_FAILED – 403hCauseDuring a Write Tag Data for ISO18000-6B or UCODE, if the lock fails, this error is returned. The write command passed but the lock did not. This could be a bad tag.SolutionTry to write a few other tags and make sure that they are placed in the RF field.FAULT_PROTOCOL_NO_DATA_READ – 404hCauseA Read Tag ID or Data command was sent but did not succeed.SolutionThe tag used has failed or does not have the correct CRC. Try to read a few others to check the HW/SW configuration.FAULT_AFE_NOT_ON – 405hCauseA command was received for an operation, like read or write, but the minimum required configuration has not been set.SolutionCheck that the region has been set, then rerun the command.
Protocol Faults190 Appendix C: Error MessagesFAULT_PROTOCOL_WRITE_FAILED – 406hCauseThis fault can occur when an operation such as write, lock, kill, set password, or initialize, fails. There are many reasons for failure.SolutionCheck that the tag is good and try another operation on a few more tags.FAULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407hCauseA command was received which is not supported by a protocol.SolutionCheck the documentation for the supported commands and protocols.FAULT_PROTOCOL_INVALID_WRITE_DATA – 408hCauseIn EPC0+, the first two bits determine the tag ID length. If the first two bits are 0b00, then the tag ID must be 96-bits. Otherwise the tag ID is 64 bits.SolutionMake sure that the first two bit have the correct values depending in the Tag ID length.FAULT_PROTOCOL_INVALID_ADDRESS – 409hCauseA command was received attempting to access an invalid address in the tag data address space.
Protocol FaultsAppendix C: Error Messages 191SolutionMake sure that the address specified is within the scope of the tag data address space and available for the specific operation. The protocol specifications contain information about the supported addresses.FAULT_GENERAL_TAG_ERROR – 40AhCauseThis error is used by the M5e GEN2 module. This fault can occur if the read, write, lock, or kill command fails. This error can be internal or functional.SolutionMake a note of the operations you were performing and contact ThingMagic at http://support.thingmagic.comFAULT_DATA_TOO_LARGE – 40BhCauseA command was received to Read Tag Data with a data value larger than expected or it is not the correct size.SolutionCheck the size of the data value in the message sent to the reader.FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40ChCauseAn incorrect kill password was received as part of the Kill Tag (26h) command. SolutionCheck the password.
Protocol Faults192 Appendix C: Error MessagesFAULT_PROTOCOL_KILL_FAILED - 40EhCauseAttempt to kill a tag failed for an unknown reasonSolutionCheck tag is in RF field and the kill password.FAULT_PROTOCOL_BIT_DECODING_FAILED - 40FhCauseAttempting to operate on a tag with an EPC length greater than the Maximum EPC length setting.SolutionCall Set Reader Configuration(9Ah) to set the Max EPC to 496 bits.FAULT_PROTOCOL_INVALID_EPC – 410hCauseThis error is used by the GEN2 module indicating an invalid EPC value has been specified for a Select operation. This fault can occur if the read, write, lock, or kill command fails. This error can be internal or functional.SolutionCheck the EPC value that is being passed in the command resulting in this error.FAULT_PROTOCOL_INVALID_NUM_DATA – 411hCauseThis error is used by the GEN2 module indicating invalid data has been specified for an operation. This fault can occur if the read, write, lock, or kill command fails.
Protocol FaultsAppendix C: Error Messages 193SolutionCheck the data that is being passed in the command resulting in this error.FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420hFAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC - 423hFAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424hFAULT_GEN2 PROTOCOL_INSUFFICIENT_POWER - 42BhFAULT_GEN2 PROTOCOL_NON_SPECIFIC_ERROR - 42FhFAULT_GEN2 PROTOCOL_UNKNOWN_ERROR - 430h
Analog Hardware Abstraction Layer Faults194 Appendix C: Error MessagesAnalog Hardware Abstraction Layer FaultsFAULT_AHAL_INVALID_FREQ – 500hCauseA command was received to set a frequency outside the specified range.For example, in North America the frequency range is from 902 MHz to 928 MHz.SolutionCheck the values you are trying to set and be sure that they fall within this range.FAULT_AHAL_INVALID_FREQ – 501hCauseWith LBT enabled an attempt was made to set the frequency to an occupied channel.SolutionTry a different channel.FAULT_AHAL_TRANSMITTER_ON – 502hCauseChecking antenna status while CW is on is not allowed.SolutionDo not perform antenna checking when CW is turned on.
Analog Hardware Abstraction Layer FaultsAppendix C: Error Messages 195FAULT_ANTENNA_NOT_CONNECTED – 503hCauseAn attempt was made to transmit on an antenna which did not pass the antenna detection when antenna detection was turned on.SolutionConnect a detectable antenna (antenna must have some DC resistance).FAULT_TEMPERATURE_EXCEED_LIMITS – 504hCauseThe module has exceeded the maximum or minimum operating temperature and will not allow an RF operation until it is back in range.SolutionTake steps to resolve thermal issues with module: Reduce duty cycle Add heat sink FAULT_LOW_RETURN_LOSS – 505hCauseThe module has detected a low return loss and has ended RF operation to avoid module damage.SolutionTake steps to resolve low return loss on receiver: Make sure antenna VSWR is within module specifications Make sure antennas are correctly attached before transmitting Check environment to ensure no occurrances of high signal reflection back at antennas.
Tag ID Buffer Faults196 Appendix C: Error MessagesTag ID Buffer FaultsThe following table lists the common faults discussed in this section.FAULT_TAG_ID_BUFFER_NOT_ENOUGH_TAGS_AVAILABLE – 600hCauseA command was received to get a certain number of tag ids from the tag id buffer. The reader contains less tag ids stored in its tag id buffer than the number the host is sending.SolutionSend a Get Tag ID Buffer command to ascertain how many tags are in the buffer. You can get the exact number of tags as long as they are less than or equal to the number returned by the previous command.FAULT_TAG_ID_BUFFER_FULL – 601hCauseThe tag id buffer is full.SolutionSend Clear Tag ID Buffer or Get Tag ID Buffer command with the number of tags to read, to get more space See Get Tag Buffer (29h) for more information.Fault Message CodeFAULT_TAG_ID_BUFFER_NOT_ENOUGH_TAGS_AVAILABLE – 600h 600hFAULT_TAG_ID_BUFFER_FULL – 601h 601hFAULT_TAG_ID_BUFFER_REPEATED_TAG_ID – 602h 602hFAULT_TAG_ID_BUFFER_NUM_TAG_TOO_LARGE – 603h 603h
Tag ID Buffer FaultsAppendix C: Error Messages 197FAULT_TAG_ID_BUFFER_REPEATED_TAG_ID – 602hCauseThe module has an internal error. One of the protocols is trying to add an existing TagID to the buffer.SolutionReport this problem to ThingMagic at http://support.thingmagic.com.FAULT_TAG_ID_BUFFER_NUM_TAG_TOO_LARGE – 603hCauseThe module received a request to retrieve more tags than is supported by the current version of the software.SolutionLocate the maximum number of supported tags in the TagID buffer in this document Get Tag Buffer (29h).
System Errors198 Appendix C: Error MessagesSystem ErrorsFAULT_SYSTEM_UNKNOWN_ERROR – 7F00hCauseThe error is internal.SolutionMake note of the operations you were executing and contact ThingMagic at http://support.thingmagic.com.FAULT_TM_ASSERT_FAILED – 7F01hCauseAn unexpected Internal Error has occurred.SolutionThis error will cause the module to switch back to Bootloader mode. When this occurs, make note of the operations you were executing, save FULL error response, and contact ThingMagic at support@thingmagic.com.
Appendix D: FPGA Support  199 Appendix D: FPGA SupportThis appendix explains how to create and update Field Programmable Gate Array (FPGA) images for the M6e-TC.Creating an FPGA Image DAT FileCreating an FPGA Image DAT file requires the use of an Actel programming environment. In the following instructions the use of Libero 8.4 is assumed. The process for other Libero versions or Actel programming environments may vary. This process assumes Verilog files have been pre-compiled and you are at the compiling stage.In order to create an FPGA image DAT file from STAPL output the following programs are required: Libero Designer - Verilog/VHDL complier to build the STAPL (.stp) file.  datgen.exe - Windows command line tool for converting the STAPL output to a .dat binary format. Follow these steps to build the DAT file:
Creating an FPGA Image DAT File200 Appendix D: FPGA Support1.    Generate the STAPL file - When generating output from Designer make sure to select the STAPL files option for the Output files to be generated as shown below.2.    Generate the DAT file - Once the *.stp file has been generated it can be fed into the datgen.exe utility to generate the .dat file. datgen must be run from the command line.
Creating an FPGA Image DAT FileAppendix D: FPGA Support 201Note:  Datgen.exe only seems to run on a local drive; operating datgen.exe from a network mapped drive may fail. Typical output, using the STAPL file: tm_fpga_top.stp file as its input, is shown below:C:\>datgen tm_fpga_top.stpDirectC Version 2.xCopyright (C) 2002 - 2007 Actel CorporationChecking STAPL file CRC value..Actual CRC = 7D55Reading STAPL file...Generating .dat files...Image size = 129680Data compression = 0Stapl Target ID = 3A121CFTool version = 1Map version = 1Core Support = 1FROM support = 0NVM support = 0NVM_Block0 support = 0NVM_Block1 support = 0NVM_Block2 support = 0NVM_Block3 support = 0NVM verifiy = 0Pass key support = 0AES key support = 0Core security Status = 0From Security Status = 0NVM_BLOCK0 Security Status = 0NVM_BLOCK1 Security Status = 0NVM_BLOCK2 Security Status = 0NVM_BLOCK3 Security Status = 0Image CRC = 244BDone.C:\>dir *.dat03/13/2009  02:15 PM           129,680 tm_fpga_top.dat1 File(s)        129,680 bytes0 Dir(s)  23,756,279,808 bytes free3.    The resulting tm_fpga_top.dat can now be loaded onto the M6e-TC using the process described in Loading an FPGA Image.
Creating an FPGA Image DAT File202 Appendix D: FPGA SupportWARNING!When loading an FPGA Image onto the M6e-TC, the Verification process checks the 16 most significant bits of the FPGA TM and TC version numbers. To pass, the TM and TC versions must start with 0x1234xxxx and 0x0010xxxx, respectively. When incrementing version numbers in the Verilog/VHDL files be sure to only change the 16 least significant bits.
Loading an FPGA ImageAppendix D: FPGA Support 203Loading an FPGA ImageThe ArbSer (see Appendix B: Using the ArbSer Application) program can also be used to load FPGA images. In order to load an FPGA image the following files are required: Arbser.exe - minimum version 3.2.0.  m6etc_fpga_mod.sim - FPGA load application image to be loaded into the M6e-TC which will be used to update the FPGA image defined by the FPGA Image file. FPGA Image file - FPGA image file in DAT format to be loaded into the M6e-TC FPGA. The following describes how to load an image onto the M6e-TC FPGA. These steps must be followed carefully. If FPGA Faults occur please follow the suggested solution and retry the image load.1.    Load the FPGA load application program into the M6e-TC using the following command:> arbser -l5a m6etc_fpga_mod.sim2.    Load the FPGA image file into flash within the application sector at address 0x8000. > arbser -l5f [fpgaimage.dat] 80003.    Initiate the image load. > arbser -goThis executes the FPGA application program and starts the FPGA programming process. The FPGA’s FlashROM is erased, the FPGA image is loaded and, finally, the image is verified (see Note below). This operation takes about three minutes to complete and should not be interrupted. On successful completion the FPGA version information is verified and write and read verify operations are performed to check the ATMEL <> FPGA interface. If these checks pass, the M6e-TC responds with status and version information similar to the response for the Get Version Command but with opcode=0x04 and the module returns to the Boot Loader mode.4.    Once the FPGA load has successfully completed the M6e-TC Application firmware must be reloaded using the following command:> arbser -l5a [M6e-TC App Firmware .sim]For FPGA version information use the Get Hardware Version (10h) command..
Loading an FPGA Image204 Appendix D: FPGA Support