Alvarion Technologies MICRO-25 Microbase station transceiver User Manual 4Motion System Manual

Alvarion Technologies Ltd. Microbase station transceiver 4Motion System Manual

Manual p1

4Motion®System ManualRelease Version: 3.0June 2010P/N 215697
Document History4Motion ii  System ManualDocument HistoryTopic Description Date IssuedFirst Release for GA July 2008Rate Limiting for the NPU Section 3.4.7.2Rate limits are configurable only by the vendor.May 2009Configuring ACLs Section 3.4.10Updated default ACLs. May 2009Configuring Performance Data Collection Section 3.4.14Added support for new counters groups, updated names.May 2009Configuring the Power Control Required C/N Level Parameters Section 3.9.4.2.2Updated Defaults for cqi, cdma, qam64-1by2, qam64-2by3, qam64-3by4, qam64-5by6.May 2009Managing the BS Keep-Alive Functionality Section 3.9.22Updated commands’ syntax. May 2009Managing the BS Idle Mode Parameters Section 3.9.23New feature May 2009Managing BS Services Added new parameters: paging-cycle, paging-offset, lm-traffic-idle-period, dl-def-rate.Updated range and default value for max-subburst.May 2009Managing Ranging Parameters Section 3.9.19The following tables were removed from operator CLI: Bandwidth Request, Handover Ranging, Initial Ranging, Periodic Ranging, Timing Correction.contbased-rsrvtimeout was removed from Ranging General table.May 2009Airframe General Parameters Sections  3.9.12.2.1,  3.9.12.3.1,  3.9.12.5.1Updated parameters:Removed: enable-ul-scrotation.Added: auto-diversity, auto-rx-enable.Corrected name: ul-duration.May 2009Airframe Cyclic Delay Parameters Section 3.9.12.2.4Updated descriptions. May 2009Airframe Linear Delay Parameters Previously Section 4.8.16.2.5Updated descriptions. May 2009
Document History4Motion iii  System ManualAirframe Mapping Parameters Previously Section 4.8.16.2.6Updated descriptions. May 2009Airframe Receive Parameters Previously Section 4.8.16.2.7Updated descriptions. May 2009Airframe Downlink Diversity Parameters Section 3.9.12.2.3Changed value range and default for the MIMO parameter.May 2009Airframe MIMO Parameters Sections  3.9.12.2.7,  3.9.12.3.4,  3.9.12.5.7New Airframe parameters table. May 2009Neighbor BS General Parameters Sections  3.9.9.2.1,  3.9.9.3.1,  3.9.9.7.1Updated parameters:Removed: restartcountucd-configchangecount and dcd-configchangecount must be set to 0.Added: paging-grp-id, nbr-strt-rng-codes.Updated range and description: preamble-idxMay 2009Service Mapping Rule R1 Profile ParametersRemoved: sdu-length, sdu-size.All possible values of datadeliverytype are supported (including rTVR and nRTVR).Updated descriptions of cir, mir, latency.Updated range for cir, mir.May 2009Service Mapping Rule R6 Profile Parameters,Updated range for cir, mir. May 2009Feedback Allocation Parameters Section 3.9.5Removed: pr-cdma, ert-poll-enable.Default value of ir-cdma changed from 20 to 2.Updated description of max-cqi.May 2009Trigger Setup Parameters Removed: hysteresismargin, timetotriggerUpdated description of avgduration-rssi.May 2009Neighbor BS Trigger Setup ParametersRemoved: hysteresismargin, timetotrigger May 2009Rate Adaptation Parameters (was previously Section 4.8.20)All Rate Adaptation parameters were removed.May 2009Scan Negotiation Parameters Section 3.9.8Removed: all parameters except enable-modify.May 2009Topic Description Date Issued
Document History4Motion iv  System ManualHandover Negotiation at SBS (was previously 4.8.12)All Handover Negotiation at SBS parameters were removed.May 2009UCD Parameters (was previously 4.8.15)All UCD parameters were removed. May 2009DCD Parameters (was previously 4.8.16)All DCD parameters were removed. May 2009Authentication Relay Parameters Section 3.9.14Removed: nonauth-macctrlratethrshld, nonauth-pduratethrshld Updated the default value of maxeaproundsthrshld to 100.Updated the default value of suspendedeapprocthrshld to 10000. Updated the description.Updated the default value of activemsthrshld to 1024.May 2009Handover Control Parameters Section 3.9.19All configurable (read-write) parameters were removed.A new read-only parameter added: CINRReuse.May 2009BS Management Alarm Thresholds (was previously 4.8.26)All BS Management Alarm Thresholds parameters were removed.May 2009BS Alarm Threshold Parameters Section 3.9.20Removed: dl-droppedpackets, unalloc-slots, dl-retransmissions, ul-retransmissions, dl-subburstdrop, ul-subburstdrop.Updated description, range and default for ul-mednoise, ul-99prcntnoise.Added: Be-exc-dl-drop-thr, rt-exc-dl-drop-thr, nrt-exc-dl-drop-thr, ugs-exc-dl-drop-thr, ert-exc-dl-drop-thr.May 2009Managing the Site General Information Section 3.4.16.7Added section on displaying the site general information.Address parameter value was changed to up to 70 characters.Removed: AsnName, Region.May 2009Managing the Unique Identifier Section 3.4.16.8Added section on displaying the site ID. May 2009Displaying the Vendor Identifier Section 3.4.16.9New feature. May 2009Topic Description Date Issued
Document History4Motion v System ManualAU Connectivity Parameters Sections  3.6.2.3,  3.6.3.3,  3.6.6.3Added new parameters: service-ip, service-mask, service-next-hop.Updated possible values of bearervlanid and the read-only InternalManagementVLANID parameters.May 2009Configuring Physical and IP Interfaces Section 3.4.2AU Fast Ethernet interfaces are not configurable.May 2009AAA Client Configuration Section 3.4.12.9.1Updated with new parameters/commands and additional changes related to support of multiple AAA clients and AAA Redundancy.In addition: Removed the auth-port and acct-port parameters. Added command for configuring the format of the Calling Station ID MAC Address.Added configuration rules for primary-serveraddr and alternate-serveraddr.Updated default and presence requirement for primary-serveraddr.Updated default and presence requirement for rad-sharedsecret.Updated description, default, possible values and presence requirement for src-intf.Added comment: If the bearer interface IP address is being modified after aaa-client configuration, you must  re-configure the src-intf parameter to "bearer" so that the aaa-client will attach itself to the new bearer interface IP address.May 2009Global RADIUS Parameters Configuration Section 3.4.12.9.2Added: alrmAaaSwitchoverRetryFailThrshld  May 2009PIU HW Version Section 3.4.16.1.2Updated parameter’s possible values. May 2009Displaying the Current Status of Shelf Components Section 3.11.1.2Added description of displayed details. May 2009Service Group Section 3.4.12.10.1srvc-grp (grp-alias) possible values changed to 1-30 characters,May 2009Topic Description Date Issued
Document History4Motion vi  System ManualService Profile Section 3.4.12.11.3.1profile-name possible values changed to 1-30 characters,May 2009Classification Rules Section 3.4.12.11.4.1clsf-rule <rulename> possible values changed to 1-30 characters,May 2009PHS Rules Section 3.4.12.12.1phs-rule <rulename> possible values changed to 1-30 characters,May 2009Bearer Plane QoS Marking Rules Section 3.4.12.7.1qos-alias possible values changed to 1-30 characters,media-type possible values changed to 1-30 characters,May 2009Log File Name Section 3.4.13.1.5file-name possible values changed to 1-50 characters,May 2009AU Maintenance VLAN ID Section 3.4.3New feature May 2009AU Connectivity Parameters Sections  3.6.2.3,  3.6.3.3,  3.6.6.3Added service interface parameters. May 2009Neighbor BS Triggers/Specific BS Triggers Sections  3.9.9.2.3,  3.9.9.7.4,  3.9.9.4Added new table: Neighbor BS Specific BS Triggers.Updated-added details on deleting Neighbor BS Triggers.May 2009Power Control Target Noise and Interference Level Parameters Sections  3.9.4.2.1,  3.9.4.3.1,  3.9.4.5.1Added: power-control-correction-factor. May 2009Managing Power Control Levels and Policies Section 3.9.4The following tables were removed:Open Loop Correction Policy,  Open Loop Correction Range,  Closed Loop - Unstable MS,  Closed Loop - MS in Network Entry,  Closed Loop Correction Range.May 2009GPS Position Parameters Section 3.4.16.2.5Added possible values details to Latitude and Longitude.May 2009GPS General Configuration Parameters Sections  3.4.16.2.2,  3.4.16.2.8Removed: AdaptorRequired May 2009GPS Clock Mode Was previously in sections  4.3.15.2.5,  4.3.15.2.11Removed May 2009Topic Description Date Issued
Document History4Motion vii  System ManualAU Properties Sections  3.6.2.1,  3.6.3.1,  3.6.6.1Updated possible values for required-type.Removed: required-ports, required-bandwidth (and the corresponding InstalledPorts and InstalledBandwidth).Updated options for port-3 power and port-4-power parameters (removed the NA option).May 2009Sector Parameters Section 3.10.1heading is not mandatory when creating a new sector. The default value is 0.May 2009Antennas Section 3.8heading is not mandatory when creating a new antenna. Limitation related to antenna heading vs. sector heading was removed).Removed: gain, altitude, beamwidth, electrical-azymuth-adjustment.Added: antenna-product-id.May 2009BS Bearer Interface Parameters Section 3.9.13Added: bearer-vlan.Updated possible values for linkusage-hardthrshld.May 2009Managing MSs for Specific MS Advanced Mode Data CollectionNew feature. May 2009Handover Negotiation at TBS ParameterThe default value of defaultactiontime was changed to 9.May 2009Power Control Maximum EIRP Section 3.9.4.2.2The default value for maxeirp was changed to -99.May 2009Neighbor Advertisement Parameters Section 3.9.6Removed: mininterval-normalload, mininterval-highload.May 2009IGMP Parameters Configurable only by the vendor. May 2009MIP Foreign Agent Parameters Configurable only by the vendor. May 2009Proxy-MIP Client Parameters Configurable only by the vendor. May 2009ASN Interface Parameters Section 3.4.12.1Configurable only by the vendor. Updated display format.May 2009Authenticator Function Parameters Section 3.4.12.2Configurable only by the vendor. Updated display format.May 2009Data Path Function Parameters Section 3.4.12.3Configurable only by the vendor. Updated display format.May 2009Context Function Parameters Section 3.4.12.4Configurable only by the vendor. Updated display format.May 2009Topic Description Date Issued
Document History4Motion viii  System ManualMS State Change Parameters Section 3.4.12.5Configurable only by the vendor. Updated display format.May 2009Connectivity Service Network (CSN) Parameters Section 3.4.12.6Configurable only by the vendor. Updated display format.May 2009Enabling/Disabling VLAN Service Interface Section 3.4.12.10.3Added default (disable). May 2009Service Flows Sections  3.4.12.11.3.3,  3.4.12.11.3.5Removed: ulSfQosSduSize, dlSfQosSduSize.Updated syntax of commands for better support of commands auto-completion.ul-unsol-intrvl not applicable for RTVR data delivery type.ulqos-trafficpriority and dlqos-trafficpriority not applicable for UGS.Updated range for ulqos-maxsustainedrate, dlqos-maxsustainedrate, ul-rsrv-rate-min, dl-rsrv-rate-min.May 2009Monitoring Software Components Removed details on counters-full and updated information is provided in the Performance Management document.May 2009Displaying Statistics for Physical and IP InterfacesRemoved details on counters-full and updated information is provided in the Performance Management document.May 2009System Log Files Sections  3.4.13.1.5,  3.11.2Corrected directory name to tftpboot/management/system_logs (added s at the end)May 2009Policy Framework Section 3.4.12.14New feature May 2009Power Feeders Configuration Section 3.4.16.3pfAuSlotNoDestination, pfAuPortNoDestination are optional.May 2009DHCP Server/Proxy Parameters Sections  3.4.12.10.4.2,  3.4.12.10.4.3.Added: Second DNS support (dnssrvr-addr2) May 2009Dry Contact Input Alarms Sections  3.4.16.4,  3.4.16.6Added alarmPolarity May 2009Displaying the Active Clear Timer and Event Rate Limit Section 3.4.15.2.6New command May 2009Topic Description Date Issued
Document History4Motion ix  System ManualODUs Sections  1.3.4,  2.1.3,  3.7.1.1,  3.7.1.2,  3.7.1.6,  3.7.2. Tables  1-3,  1-6,  1-10,  1-22.Added new ODUs: ODU-HP-2.3-WCS,  ODU-2340-2400-000N-36-1X1-N-0,  ODU-2480-2690-000N-38-4X2-N-0.Removed: 2x1 ODUs.Updated the list of ODU types in CLI (including types that are not available yet).May 2009ODU General Parameters Sections  3.7.1.2,  3.7.1.3,  3.7.1.6.Removed: heater-existence May 2009Antennas Table 1-39, Table 1-42Added antennas:ANT.2.3-2.7GHz, D/S,65°,16±0.5dBi, ANT.3.5GHz, D/S,65°,16±0.5dBiMay 2009Airframe Uplink Feedback Zone Parameters Section  3.9.12.2.4Updated limitation for subchannels. May 2009Service Mapping Rule R6 Profile ParametersUpdated range for mediaflowtype. May 2009Configuring General Service Mapping Rule ParametersUpdated description of the srvc parameter. May 2009Performance Data Collection Section 3.4.14, Table 3-5Updated syntax of commands for better support of commands auto-completion.May 2009Configuring Common Parameters of a Service Group Section 3.4.12.10.2Updated syntax of commands for better support of commands auto-completion.Updated description of dhcp-ownaddr.May 2009Enabling/Disabling VLAN Service Interface Section 3.4.12.10.3Updated syntax of commands for better support of commands auto-completion.May 2009Configuring the DHCP Server/Proxy/Relay Section 3.4.12.10.4Updated syntax of commands for better support of commands auto-completion.May 2009IP-IP Service Interface Parameters Sections  3.4.12.8.2.1,  3.4.12.8.3Updated syntax of commands for better support of commands auto-completion.May 2009Displaying Configuration Information for the Service Interface Section 3.4.12.8.6Updated May 2009Topic Description Date Issued
Document History4Motion x System ManualVLAN Service Interface Parameters Sections  3.4.12.8.2.2,Updated syntax of commands for better support of commands auto-completion.Updated possible values and description for vlan-id.Added mask for dflt-gw-ip.May 2009QinQ Service Interface Parameters Section 3.4.12.8.2.3Updated syntax of commands for better support of commands auto-completion.Updated possible values and description for vlan-id.May 2009ASN-GW Keep-Alive Parameters Section 3.4.12.14Updated syntax of commands for better support of commands auto-completion.May 2009Configuring Power Feeders Section 3.4.16.3.1Updated syntax of commands for better support of commands auto-completion.May 2009RF Frequency Section 3.9.10Updated possible values. May 2009General Neighbor BS Parameters Section 3.9.9.2.1Updated possible values. May 2009Bearer Interface IP Address Section 3.4.2.3.3Added comment: After changing the bearer IP address, save configuration and reboot to apply changed IP address on ASN and CSN interfaces.May 2009IP Connectivity Mode Section 3.4.1.1Added comment: You must save the configuration for a change in connectivity mode to take effect after next reset.May 2009Next Boot Mode Section 3.4.4.1Added comment: You must save the configuration for a change in boot mode to take effect after next reset.May 2009Restoring the Factory Default Configuration With Connectivity Section 3.4.5.4.7New feature. May 2009displaying Failures in Configuration Restore Operations Section 3.4.5.4.8New feature. May 2009Privilege Levels Sections  3.1.5.5,  3.1.6The highest privilege level available for users is 10.May 2009DGW Profile Sections 3.4.12.11.3.1,  3.4.12.11.3.3.1Added a note (parameters related to DGW profile are not applicable in current release).May 2009Topic Description Date Issued
Document History4Motion xi  System ManualPower Feeders Requirements Section 2.3.3.3Required only in configurations with 6 AUs where each AU is connected to 4 2.x GHz or 3.5 GHz 1x1 ODUs.May 2009Configuring the Properties of the Physical Interface Section 3.4.2.1.2Physical interfaces can be configured when the interface is enabled.May 2009Managing AUs Section 3.6Up to 6 AUs may be active (removed limitation on number of AUs that can provide services).May 2009Managing BSs Section 3.9Removed the requirement to explicitly configure at least one parameter in tables with no mandatory parameters.May 2009Apply command Table 3-28, Sections  3.9.4,  3.9.16,  3.9.19.Apply command not required for Power Control Levels and Policies, Control Traffic QoS Marking Rules and Ranging parameters, unless none of the BS General parameters was configured.May 2009BS General Parameters Section 3.9.3Added ul-def-rate, dl-def-rate. May 2009Commissioning-NPU Local Connectivity-External Management Interface Section 2.1.3.3No need to shut-down external interface before configuring IP parameters.May 2009Commissioning-Completing the Site Configuration Using AlvariSTAR-Equipment Configuration-AU Section 2.2.4.1Updated (only supported Type is AU 4x4 Modem, Ports and Bandwidth parameters were removed).May 2009Commissioning-Completing the Site Configuration Using AlvariSTAR-Equipment-Antenna Section 2.2.4.3Updated: Added Antenna Product Type, Number of Ports applicable only if Antenna Product Type is set to Empty, Heading is not mandatory.May 2009Commissioning-Completing the Site Configuration Using AlvariSTAR-BS Configuration Section 2.2.6Removed the requirement for clicking Apply on Radio Advanced screen and Connectivity Advanced screen.May 2009Commissioning-Completing the Site Configuration Using AlvariSTAR-ASNGW ConfigurationIt is not mandatory to define AAA client (the default client can be used).May 2009Topic Description Date Issued
Document History4Motion xii  System ManualCreating a Sector Association Entry Section 3.10.2.1Updated association rules (relation between antenna-type, auto-diversity and auto-rx-enable parameters.May 2009Changes in Site Configuration Section 2.1.3.4Reset is required only for a change in Connectivity Mode.June 2009Accessing the CLI from a Remote Terminal Section 3.1.2.2No need to disable/enable the interface when configuring an IP Address.June 2009Adding/Modifying Users Section 3.1.6.1.1Updated the command’s syntax. June 2009Displaying the IP connectivity Mode Section 3.4.1.2Updated display format. June 2009Managing VLAN Translation Section 3.4.2.1.3Updated ranges.VLAN Translation entry can be created also when VLAN Translation is disabled.June 2009Configuring IP Interfaces Section 3.4.2.3VLAN ID of Local Management Interface is configurable.It is not necessary to shut down an IP interface for configuring its parameters.June 2009Configuring a QoS Classification Rule Section 3.4.8.2.2IP address of local-management can also be used as host source IP address.June 2009Configuring Static Routes Section 3.4.9Added a note regarding automatically added/deleted kernel routes. June 2009Configuring ACLs in the Standard Mode Section 3.4.10.1.2Removed paragraph on Standard ACL 1 which was previously available by default.June 2009Configuring Permit/Deny Rules from/to a Specific Protocol and Source/Destination IP Addresses Section 3.4.10.1.3.1Any IANS value can be configured for the protocol-type parameter, including IP, OSPF and PIM.June 2009Attaching/De-attaching ACLs to/from an Interface Section 3.4.10.3Removed paragraph on Standard ACL 1 which was previously available by default.June 2009Enabling the Interface Configuration Mode Section 3.4.10.3.1By default, all traffic destined towards the AUs is denied and all traffic towards the NPU is permitted.June 2009Deleting Next-hop IP Address-Network ID Mappingsnw-id parameter is optional. June 2009Topic Description Date Issued
Document History4Motion xiii  System ManualManaging the Authenticator Function Section 3.4.12.2Updated descriptions for eapTimerTransfer and eapCounterTransferMax.June 2009Managing the Data Path Function Section 3.4.12.3Updated descriptions of dpTimerInitPathRegReq, dpCounterInitPathRegReqMax, dpTimerMsDeregReq, dpCounterMsDeregReqMax, dpTimerPathRegReq, dpCounterPathRegReqMax, dpTimerPathRegRsp, dpCounterPathRegRspMax.June 2009Managing the Context Function Section 3.4.12.4Updated descriptions of all parameters. June 2009Managing the MS State Change Functionality Section 3.4.12.5Updated descriptions of msscfnTimerMsscRsp, msscfnCounterMsscRspMax, msscfnTimerMsscDrctvReq, msscfnCounterMsscDrctvReqMax.June 2009Configuring Bearer Plane QoS Marking Rules Section 3.4.12.7Corrected value: Up to a maximum of 20 Bearer Plane QoS Marking Rules can be defined.June 2009Deleting Bearer Plane QoS Marking Rules Section 3.4.12.7.5"int_default" and "ext_default" Bearer Plane QoS Marking Rules cannot be deleted.June 2009Enabling the Service Interface Configuration Mode\Creating a Service Interface Section 3.4.12.8.1Updated the value of the Service Interface alias parameter (1-30 characters).June 2009Configuring Parameters for IP-IP Service Interface Section 3.4.12.8.2.1srcaddr is mandatory. The only allowed value is the Bearer IP Address.dstaddr is mandatory.Updated description of dstaddr.June 2009Configuring Parameters for VLAN Service Interface Section 3.4.12.8.2.2vlan-id and dflt-gw-ip are mandatory. June 2009Configuring Parameters for QinQ Service Interface Section 3.4.12.8.2.3vlan-id is mandatory. June 2009Topic Description Date Issued
Document History4Motion xiv  System ManualConfiguring the AAA Client Functionality Section 3.4.12.9rad-CallingStationId parameter added to AAA Client parameters config command (instead of config aaaserverMACFormat command added in a previous version of this release).June 2009Restoring Operation with the Primary Server Section 3.4.12.9.1.2Updated command syntax and description. June 2009Deleting the AAA Client Section 3.4.12.9.1.6“default” client cannot be deleted. June 2009Configuring DHCP Server Parameters Section 3.4.12.10.4.2.1No need to delete service group for updating pool-minaddr & pool-maxaddr values.Corrected range for lease-interval (24-4294967295).Added rules for pool-minaddr & pool-maxaddr.Added rules for renew-interval.June 2009Deleting a Service Group Section 3.4.12.10.9To delete a VLAN type service group, first execute the "no vlan-enable" command.June 2009Configuring Parameters for the Policy Framework Previously Section 4.3.11.17.2aaa-alias must be the alias of an active AAA client.June 2009Managing the ASN-GW Keep-Alive Functionality Section 3.4.12.14Updated description of the feature. June 2009Configuring ASN-GW Keep-Alive Parameters Section 3.4.12.14.1Added error condition.Updated range and default for rtx-time.June 2009Configuring BS Keep-Alive Parameters Section 3.9.22.1Added error condition. June 2009Configuring the SNMP Manager Section 3.4.15.1Clarified that each SNMP Manager entry is uniquely identified by the pair of values for the Read Community and Write Community.June 2009Configuring the Trap Manager Section 3.4.15.2Added note: A route to forward traps to a configured Trap Manager IP address must exist.June 2009Displaying the Trap Rate Limit Section 3.4.15.2.5Updated description. June 2009Topic Description Date Issued
Document History4Motion xv  System ManualConfiguring the Date and Time Section 3.4.16.2.3Corrected the presence of UTC to Optional. June 2009Configuring Power Feeders Section 3.4.16.3.1Added note on error condition. June 2009Displaying the Unique Identifier for the 4Motion Shelf Section 3.4.16.8.2Corrected command’s syntax. June 2009Displaying the Vendor Identifier Section 3.4.16.9Updated description. June 2009Displaying Location Information for the 4Motion ShelfThis section (previously Section 4.10.1.4) was removed (described in Section 3.4.16.7.2).June 2009Displaying the Unique Identifier for the 4Motion ShelfThis section (previously Section 4.10.1.5) was removed (described in Section 3.4.16.8.2).June 2009Enabling the Port Monitoring Session Section 3.12.2.1Updated command’s syntax. June 2009Disabling a Port Monitoring Session Section 3.12.2.1Updated command’s syntax.Updated descriptionJune 2009Upgrading the NPU: Step 2: Triggering Software DownloadAdded error condition (available memory). June 2009Upgrading the AU Step 3: Creating the AU-to-Image MappingRemoved error condition (regarding mapping the AU to an image that is not residing in the AU flash).June 2009Displaying the Card Types Installed in Shelf Slots 1 - 9 Section 3.11.1.1New June 2009ODU Names Table 1-6, ODU-2340-2400-000N-36-1X1-N changed to ODU-HP-2.3bJune 2009Configuring Bearer Plane QoS Marking Rules Section 3.4.12.7Updated description of the feature. June 2009Deleting Source Addresses Section 3.4.12.11.4.5.5Updated command syntax. June 2009Deleting Destination Addresses Section 3.4.12.11.4.6.5Updated command syntax. June 2009Topic Description Date Issued
Document History4Motion xvi  System ManualEnabling the Source Address Configuration Mode\ Creating a New Source Address Section 3.4.12.11.4.5.1Added Privilege Level definition. June 2009Displaying the Status of the Manual Backup Procedure Section 3.4.5.4.2Updated Privilege Level (10) June 2009Displaying the Automatic Backup Time Section 3.4.5.4.4Added to manual. June 2009Displaying Failures in Configuration Restore Operations Section 3.4.5.4.8Updated Privilege Level (10) June 2009Displaying the Currently Stored Backup Configuration Files Section 3.4.5.4.9Updated Privilege Level (10) June 2009Displaying Configuration Information for SNMP Managers Section 3.4.15.1.3Updated Privilege Level (10) June 2009Displaying Configuration Information for Trap Managers Section 3.4.15.2.4Updated Privilege Level (10) June 2009Displaying Status Information for HARQ Maximum Retransmissions Parameter  (was previously section 4.8.30)Removed. June 2009Configuring Power Control Target Noise and Interference Level Parameters Section 3.9.4.2.1Updated default value of pusc to -127. June 2009Specifying Configuration Parameters for the L3 Classification Rule Section 3.4.12.11.4.2Added consistency and configuration rules for iptos-low and iptos-high.June 2009Enabling the Source Port Configuration Mode\ Creating a New Source Port Section 3.4.12.11.4.7.1Added consistency rules for start-port and end-port.June 2009Enabling the Destination Port Configuration Mode\ Creating a New Destination Port Section 3.4.12.11.4.8.1Added consistency rules for start-port and end-port.June 2009Topic Description Date Issued
Document History4Motion xvii  System ManualEnabling Protocol Lists Section 3.4.12.11.4.4.2Added consistency rules-impact of enabling destination port range June 2009Enabling the Destination Port Range Section 3.4.12.11.4.8.2Added consistency rules-impact on parameters of IP protocol lists June 2009Enabling the Destination Port Range Section 3.4.12.11.4.7.2Added consistency rules-impact on parameters of IP protocol lists June 2009Configuring the Position Section 3.4.16.2.5Updated ranges for longitude and latitude. June 2009Managing Handover Negotiation at SBS ParametersThe previously removed section was brought back with one new parameter to support the Blackout Period feature.June 2009Configuring the AAA Client Functionality Section 3.4.12.9Removed all commands and parameters associated with AAA server redundancy.Only a single client (default) is supported.June 2009Configuring the Output Parameters for Bearer Plane QoS Marking Rules Section 3.4.12.7.2Added a note-for VLAN Service Interface only VLAN Priority marking is relevant.June 2009Managing Secure Shell (SSH) Parameters Section 3.1.7New section June 2009Using Miscellaneous Commands Section 3.1.5.4Update description of exit command. June 2009Managing the Session Section 3.1.8New section June 2009Managing Service Groups Section 3.4.12.10Added explanations on the different service group types.Added new type (VPWS-Mapped).Added acctInterimTmr parameter and updated range/default for acct parameter in IP Service Group configuration.Updated description for ms-loop.Changed structure/headings and added new sections for configuring VPWS service groups.Updated description of dhcp-ownaddr.June 2009Configuring Antenna Parameters Section 3.8.2Updated value range for latitude and longitude, updated default for latitude.June 2009Topic Description Date Issued
Document History4Motion xviii  System ManualMacro Outdoor BTS Sections  1.2.1,  1.3,  1.3.2 (new),  1.5.6,  1.5.7,  1.5.9,  1.5.10.2.1 (new),  1.5.10.2.2 (new),  1.5.10.2.3 (new),  2.4 (new).  3.1.1 (new)New product line June 2009Configuring the Site General Information for the 4Motion Shelf Section 3.4.16.7.1Removed ProductType (not configurable)  June 2009Displaying the Site General Information Parameters Section 3.4.16.7.2Product Type has several options. June 2009Replacing a PIU Section 2.3.10.4Updated procedure June 2009Output Alarms Section 3.4.16.5.1Corrected explanation of N.C. and N.O. terms.June 2009Displaying the Currently Stored Backup Configuration Files Section 3.4.5.4.9Added description of the file’s name format. June 2009Restoring the Configuration Defined in the Backup Configuration File Section 3.4.5.4.5Added description of the file’s name format. June 2009Downloading a Configuration File/Vendor Startup File from an External Server Section 3.4.5.2Updated section, added info related to Vendor Startup file and file name format.June 2009Displaying the Status of the last File Download Operations Section 3.4.5.3New section June 2009Configuring Service Parameters Updated range for paging-cycle, paging-offset and lm-traffic-idle-period.August 20094x2 ODU Installation Guidelines Section 2.1.4.2Updated August 2009Configuring R6 Profile Parameters Updated value range for cir and mir parameters.August 2009Configuring R1 Profile Parameters Updated value range for cir and mir parameters.August 2009Topic Description Date Issued
Document History4Motion xix  System ManualSpecifying Service Flow Configuration Parameters Section 3.4.12.11.3.3.2Updated value range for ulqos-maxsustainedrate, dlqos-maxsustainedrate, ul-rsrv-rate-min, dl-rsrv-rate-min.August 2009Configuring Airframe MIMO Parameters Section 3.9.12.2.7Updated default value of bcast-msgzone-loc. August 2009Managing the Policy Framework (was previously section 4.3.11.17)Removed August 2009Managing Handover Negotiation at SBS (was previously 4.8.12)Removed August 2009Configuring Alarm Threshold Parameters Section 3.9.20.1Updated value range and default for ul-mednoise and ul-99prcntnoise.August 2009Managing Service Interfaces Section 3.4.12.8Updated general description.Removed QinQ Service Interface.August 2009Default login ID Section 3.1Changed from root to admin, with privilege level 10.August 2009Configuring Service Flows Section 3.4.12.11.3.3Only IPv4CS service flows can be configured in the device.August 2009Configuring ACLs Section 3.4.10Added details of modified ACL 1. August 2009Configuring ODU Port Parameters Section 3.7.2.2Added warning - do not disable ODU ports August 2009Configuring Airframe General Parameters Section 3.9.12.2.1auto-diversity and auto-rx-enable are forced to true (setting to false will be ignored).August 2009Configuring Airframe Cyclic Delay Parameters Section 3.9.12.2.4Updated dependencies. The values are set by internal logic.August 2009Configuring Airframe Linear Delay Parameters Previously Section 4.8.16.2.5Updated dependencies. The values are set by vendor file.August 2009Configuring Airframe Mapping Parameters Previously Section 4.8.16.2.6Updated dependencies. The values are set by internal logic.August 2009Topic Description Date Issued
Document History4Motion xx  System ManualConfiguring Airframe Receive Parameters Previously Section 4.8.16.2.7The values are set by internal logic. August 2009Configuring Antenna Parameters Section 3.8.2Updated possible values and default for antenna-product-id.August 2009Configuring Airframe Uplink Feedback Zone Parameters Section 3.9.12.2.4Value of subchannels is set internally according to bandwidth.August 2009Configuring Airframe Downlink Data Zone Parameters Section 3.9.12.2.5Value of subchannels is set internally according to bandwidth.August 2009Configuring Airframe Uplink Data Zone Parameters Section 3.9.12.2.6Value of subchannels-number is set internally according to bandwidth. startallocation is hard-coded (value=0).August 2009Configuring Airframe MIMO Parameters Section 3.9.12.2.7bcast-msgzone-loc is hard coded (set to nonSTCzoneOnly).August 2009Configuring Ranging Parameters Section 3.9.19.2Updated valid values for start-of-rng-codes. August 2009Managing BS Feedback Allocation Parameters Section 3.9.5Updated valid values for ir-cdma.The value for max-cqi is set by vendor file. Updated default value according to bandwidth.August 2009Configuring Power Control Target Noise and Interference Level Parameters Section 3.9.4.2.1cqi-ack-ranging cannot be modified. August 2009Configuring the Power Control Maximum EIRP Section 3.9.4.2.2maxeirp cannot be modified. August 2009Configuring the Power Control Required C/N Level Parameters Section 3.9.4.2.2All parameters cannot be modified. August 2009Configuring Service Parameters max-subburst is not relevant. trgt-err-rate cannot be modified.August 2009Topic Description Date Issued
Document History4Motion xxi  System ManualConfiguring the Unique Identifier for the 4Motion Shelf Section 3.4.16.8.1A change in site identifier will take effect after reset.Special procedure needed when changing the site identifier of a device managed by AlvariSTAR.August 2009Managing the IP Connectivity Mode Section 3.4.1Added AU maintenance IP domain.Added note on VLAN operation mode of the ports (tagged/untagged).August 2009Configuring Physical and IP Interfaces Section 3.4.2Added AU maintenance IP domain. August 2009Configuring Parameters for VLAN Service Interface Section 3.4.12.8.2.2A Service Interface VLAN ID shall not conflict also with AU Maintenance VLAN.August 2009Configuring BS Keep-Alive Parameters Section 3.9.22.1Updated default values of tx-cnt and rtx-time. August 2009Managing Scheduler Parameters Section 3.9.24New feature August 2009Configuring AU Connectivity Section 3.6.2.3Updated description of service-ip. August 2009Chapter 2 - Installation Updated instruction for installing 4x2 ODUsUpdated instructions for installing GPS Receiver.Added Macro Outdoor BTS installation instructionsAugust 2009ODUs Tables  1-3,  1-6 (new),  1-6,  1-10,  1-11 (new),  1-16 (new), Section 3.7.1.1 (added note, removed tables of currently available ODUs)Updated ODUs August 2009Radio Standards Section 1.5.8Added FCC part 25 August 2009Managing Service Interfaces Section 3.4.12.8QinQ Service Interface is supported (for special needs)August 2009Configuring Service Profiles Section 3.4.12.11.3VLAN CS Service Flows can be configured for the Default Service ProfileAugust 2009Topic Description Date Issued
Document History4Motion xxii  System Manual1x1 ODU LEDs Table 2-3ETH connector is functional August 2009Configuring General Neighbor BS Parameters Section 3.9.9.2.1Updated range for frequency August 2009Configuring the RF Frequency Parameter Section 3.9.10.1Updated range for frequency August 2009Configuring Bearer Traffic QoS Marking Rule Parameters Section 3.9.16.2Updated range for srvcflow-datadeliverytype. August 2009Configuring/Modifying the VLAN ID for an IP Interface Section 3.4.2.3.5Added note that after changing the bearer interface VLAN ID the bearervlanid of all AUs must be changed to the same value.August 2009Restoring the Factory Default Configuration Section 3.4.5.4.6Added note-reset required. August 2009Restoring the Factory Default Configuration With Connectivity Section 3.4.5.4.7Added note-reset required. August 2009Deleting Service Flows Section 3.4.12.11.3.3.7Corrected range for flow-id August 2009Configuring ASN-GW Keep-Alive Parameters Section 3.4.12.14.1Corrected command syntax August 2009Configuring Logging Section 3.4.13Added note: Logging configuration reverts to default after NPU reset.August 2009Managing the BS Idle Mode Parameters Section 3.9.23Updated description of the feature. August 2009IF Cables Tables  2-1,  2-2Limitations/Max Length for 3.5 GHz units are the same as for other ODUsAugust 2009Commissioning Section 2.1No need to configure ACL August 2009Topic Description Date Issued
Document History4Motion xxiii  System ManualConfiguring Airftame Parameters Section 3.9.12.2Removed sections related to Cyclic Delay Parameters, Linear Delay Parameters, Mapping Parameters and Receive Parameters. In General Parameters, auto-diversity and auto-rx-enable were removed.Added notes regarding parameters that are not relevant (ignored) in Uplink Feedback Zone Parameters, Downlink Data Zone Parameters, Uplink Data Zone Parameters, MIMO Parameters. August 2009Restoring Default Values for Airframe Parameters Section 3.9.12.3Removed sections related to Cyclic Delay Parameters, Linear Delay Parameters, Mapping Parameters, Receive Parameters and Uplink Data Zone Parameters. In General Parameters, auto-diversity and auto-rx-enable were removed. Added a note that the command for restoring the default values for Uplink Data Zone parameters is not applicable for the current release.Added notes regarding parameters that are not relevant (ignored) in MIMO Parameters.August 2009Displaying Configuration Information for Airftame Parameters Section 3.9.12.5Removed sections related to Cyclic Delay Parameters, Linear Delay Parameters, Mapping Parameters and Receive Parameters.August 2009Managing BS Feedback Allocation Parameters Section 3.9.5Added a note related to max-cqi parameter that cannot be modified.August 2009Configuring Power Control Target Noise and Interference Level Parameters Section 3.9.4.2.1Added a note related to cqi-ack-ranging parameter that cannot be modified.August 2009Restoring the Default Values of Power Control Target Noise and Interference Level Parameters Section 3.9.4.3.1Added a note related to cqi-ack-ranging parameter that cannot be restored to default value.August 2009Topic Description Date Issued
Document History4Motion xxiv  System ManualManaging Power Control Levels Section 3.9.4Removed sections related to configuring or restoring the default value of Maximum EIRxP. Added a note that this command is not applicable for the current release. Updated the description for displaying configuration values of the parameter.Added a note regarding nilevels cqi-ack-ranging parameter that cannot be modified.Required C/N Levels are configurable.Updated default value for Required C/N Levels: ack, cqi, cdma.August 2009Configuring BS Service Parameters Added a note regarding parameters that are not relevant or cannot be modified.August 2009Restoring Default Values for BS Service ParametersAdded a note regarding parameters that are not relevant or cannot be modified.August 2009Managing AUs Section 3.6Removed sections related to configuring, restoring default values and displaying configured values of reserved parameters. Added a not that these commands are not applicable for current release.September 2009Configuring ODUs Section 3.7.1Removed sections related to configuring, restoring default values and displaying configured values of reserved parameters. Added a not that these commands are not applicable for current release.September 2009Managing BS Reserved Parameters Section 3.9.21Removed sections related to configuring, restoring default values and displaying configured values of reserved parameters. Added a not that these commands are not applicable for current release.September 2009Managing the IGMP Functionality Removed details, added a note that relevant show commands are not applicable since the feature is not supported in the current release.September 2009Managing the MIP-Foreign Agent FunctionalityRemoved details, added a note that relevant show command is not applicable since the feature is not supported in the current release.September 2009Managing the Proxy-MIP Client FunctionalityRemoved details, added a note that relevant show command is not applicable since the feature is not supported in the current release.September 2009Topic Description Date Issued
Document History4Motion xxv  System ManualConfiguring the 4Motion Shelf Section 3.4.16Updated descriptions of components. September 2009Configuring Bearer Plane QoS Marking Rules Section 3.4.12.7Updated general description September 2009Configuring Power Control Target Noise and Interference Level Parameters Section 3.9.4.2.1Updated range for pusc. September 2009Manual MS De-registration Section 3.5.1Updated-added the options to de-rergister am MS by its MSID (MAC address) and de-register all MSs served by a specified BS.October 2009Transferring Files from the NPU Flash to a TFTP Server Section 3.4.13.1.8New feature October 2009Creating a Collected System Logs File Section 3.4.13.1.7New feature October 2009Displaying System Files Section 3.11.2Added the command “show saved system logs”.October 2009Displaying MS Information Section 3.5.2New display option (“brief”). October 2009ODU Tx Power Control Range Tables  1-6,  1-8, Section 3.7.2.1,.Updated to 10 dB for all ODUs October 2009Commissioning Sections  2.1.3.2,  2.1.3.3,  2.1.4.Updated specified sections October 2009Accessing the CLI from a Remote Terminal Section 3.1.2.2Added details on creating IP level connectivity October 2009Using the History Feature Section 3.1.5.3Updated-up to 14 previously executed commands can be displayedOctober 2009Privilege Levels Sections  3.1.5.5,  3.1.6Correction-the lowest level is 1 October 2009Configuring Static Routes Section 3.4.9Updated description of default “Any Destination” route.October 2009Displaying IP Routes Section 3.4.9.3Added a note: IP routes connected to an interface that is shut down are not displayed.October 2009Topic Description Date Issued
Document History4Motion xxvi  System ManualAdding a Static Route Section 3.4.9.1Updated: ip_nexthop must be in the subnet of one of the NPU IP interfaces.October 2009Displaying the Temperature of the Shelf Section 3.11.1.3New command October 2009Service Flows-Configuring Uplink/Downlink Classification Rule Names Section 3.4.12.11.3.3.4.Added: If no classifier is associated with the service flow for one or both directions, it means any traffic.October 2009Managing VLAN Translation Section 3.4.2.1.3Updated description October 2009Configuring ACLs Section 3.4.10Updated description-priorities of ACLs October 2009Managing Global RADIUS Configuration Parameters Section 3.4.12.9.2Removed alrmAaaSwitchoverRetryFailThrshld.Added vlan-classf-bit-alignNovember 2009Configuring the DHCP Relay Option 82 Parameters Section 3.4.12.10.4.4.2Added two new options to Subopt1value and Subopt2valueNovember 2009Configuring the Next-hop IP Address-Network ID Mapping, Managing the IGMP Functionality, Managing the MIP-Foreign Agent Functionality, Managing the Proxy-MIP Client FunctionalityRemoved. November 2009Topic Description Date Issued
Document History4Motion xxvii  System ManualODU Types Table 1-3, Section 1.5.3Added new ODUs:ODU-2300-2400-000N-38-2X2-N-0ODU-2485-2690-000N-38-2X2-N-0ODU-2590-2690-000N-38-2x2-N-0ODU-3345-3400-000N-33-1x1-N-0ODU-3400-3600-000N-37-2x2-N-0ODU-3400-3600-000N-37-4x2-BF-N-0ODU-3650-3700-000N-22-1x1-N-0Added Beam Forming Support specifications to all 4x2 ODUs tables.Added ETSI compliance requirements for 2.5 GHz ODUs.February 2010ODUs Specifications Section 1.5.3Updated Power Consumption specifications February 20102.3-2.7 GHz DDP Antennas Table 1-38Added BS-EDT-DDP-ANT 2.3-2.7 (No RET support).February 2010Macro Outdoor Units Section  1.3.2New unit types with 2-channels AUs. February 2010Micro Outdoor BTS New product line. February 2010GPS for Macro BTS Sections  1.3.7.1,  1.5.10.4Added details on new GPS receiver, updated specifications (added Interface specs) of Timing GPS.February 2010Managing BS Services, Managing Service Mapping RulesRemoved February 2010Managing the BTS Load Balancing Parameters Section 3.4.11New feature February 2010Managing the BS ASN-GW Load Balancing Parameters Section 3.9.25New feature February 2010Airframe MIMO Parameters Sections  3.9.12.2.7,  3.9.12.3.4,  3.9.12.5.7Removed bcast-msgzone-loc February 2010Configuring the Airframe Downlink Diversity Mode Parameter Section 3.9.12.2.3Added description of supported modes.Added beamForming optionFebruary 2010Topic Description Date Issued
Document History4Motion xxviii  System ManualAirframe Dynamic Permutations Parameters Section 3.9.12Removed (changed to vendor parameters) February 2010Configuring Airframe General Parameters Section 3.9.12.2.1Updated value range for ul-duration and frame-offset. Added nbr-beam-forming.February 2010Configuring Airframe Map Zone Parameters Section 3.9.12.2.2Added RCID-Usage February 2010Configuring Airframe Uplink Feedback Zone Parameters Section 3.9.12.2.4Removed subchannels (changed to vendor parameter)February 2010Configuring Airframe Downlink Data Zone Parameters Section 3.9.12.2.5Removed subchannels (changed to vendor parameter)February 2010Configuring Airframe Uplink Data Zone Parameters Section 3.9.12.2.6Removed subchannels-number (changed to vendor parameter) and startallocation (obsolete-hard coded to 0).permbase is mandatory when creating a new BS.February 2010Restoring the Default Values of Airframe General Parameters Section 3.9.12.3.1Added nbr-beam-forming (new parameter) and frame-offsetFebruary 2010Restoring the Default Values of Airframe Map Zone Parameters Section 3.9.12.3.2Added RCID-Usage February 2010Displaying Configuration Information for Airframe General Parameters Section 3.9.12.5.1Added NeighborBeamForming February 2010Displaying Configuration Information for Airframe Map Zone Parameters Section 3.9.12.5.2Added RcidUsage February 2010Displaying Configuration Information for Airframe Uplink Feedback Zone Parameters Section 3.9.12.5.4Removed subchannels February 2010Displaying Configuration Information for Airframe Downlink Data Zone Parameters Section 3.9.12.5.5Removed subchannels February 2010Topic Description Date Issued
Document History4Motion xxix  System ManualDisplaying Configuration Information for Airframe Uplink Data Zone Parameters Section 3.9.12.5.6Removed subchannels-number and startallocation.February 2010Managing BS Feedback Allocation Parameter Section 3.9.5Removed max-cqi (changed to vendor parameter)February 2010Managing BS Bearer Interface Parameters Section 3.9.13Removed linkusage-hardthrshld and mtu (changed to vendor parameters). Added ASNGWStatus (read-only).February 2010Managing BS General Parameters Section 3.9.3Added dl-def-rate-for data.Changed dl-def-rate to dl-def-for-management and updated default value.Added deploymentFebruary 2010Configuring Alarm Threshold Parameters Section 3.9.20.1Updated descriptions and defaults of ul-mednoise and ul-99prcntnoise.February 2010Configuring Power Control Parameters Section 3.9.4.2Changed pusc to target-ni. Updated step size to 1. Removed cqi-ack-ranging.February 2010Managing Handover Negotiation at TBS ParametersRemoved. defaultactiontime is obsolete (calculated automatically), fastrangingalloc changed to vendor parameter)February 2010Configuring AU Parameters Section 3.6.2Added support for AU type au2x2 (2-ports AU).February 2010Managing the BS Idle Mode Parameters Section 3.9.23Removed idle-Mode-ms-initiated-for-ugs (changed to vendor parameter)February 2010Managing Software Upgrade Section 3.2Moved to Operation Chapter (was previously an Appendix)February 2010Managing AAA Client Configuration Section 3.4.12.9.1Added support for AAA server redundancy.src-intf can be configured to either the bearer or external-management IP interface.February 2010Configuring the DHCP Relay Option 82 Parameters Section 3.4.12.10.4.4.2Added new option to Subopt1value and Subopt2valueFebruary 2010Topic Description Date Issued
Document History4Motion xxx  System ManualMapping of Macro Outdoor BTS AUs to Slot # Table 3-1Corrected mapping February 2010Managing Neighbor BSs Appendix 3.9.9Removed Trigger Setup parameters. February 2010Managing Trigger Setup Parameters Removed February 2010Displaying Configuration and Status Information for ODU Ports Section 3.7.2.6Added new read-only parametersodu-status-maskRSSIFebruary 2010Managing Service Interfaces Section 3.4.12.8removed mtu (changed to vendor parameter) February 2010Configuring IP Interfaces Section 3.4.2.3removed mtu (changed to vendor parameter) February 2010Managing the Hot-Lining Feature Section 3.4.12.13New feature. February 2010Configuring BS Keep-Alive Parameters Section 3.9.22.1Corrected Possible Values range of rtx-cnt, Updated Default of rtx-time.February 2010configuring ASN-GW Keep-Alive Parameters Section 3.4.12.14.1Updated range and default for rtx-cnt, updated range for rtx-time.February 2010Configuring General Configuration Parameters for the GPS Section 3.4.16.2.2Updated default value for HoldoverTimeout February 2010Managing the Context Function Section 3.4.12.4Updated to reflect the ability to configure the ms-capacity-threshold parameter.February 2010Managing the Data Path Function Section 3.4.12.3Updated to reflect the ability to configure the throughput-threshold parameter.February 2010Configuring/Displaying the Daylight Saving Parameters Sections  3.4.16.2.4,  3.4.16.2.10New feature February 2010Creating a Sector Association Entry Section 3.10.2.1Updated configuration rules February 2010Sector Connections Schemes Appendix ANew section, replacing previous Antenna Configurations sectionFebruary 2010Topic Description Date Issued
Document History4Motion xxxi  System ManualConfiguring Parameters for IP-IP Service Interface Section 3.4.12.8.2.1Updated Description, Presence and Default Value for srcaddr and dstaddr.February 2010Configuring Parameters for VLAN Service Interface Section 3.4.12.8.2.2Updated Description, Presence and Default Value for vlan-id and dflt-gw-ip.February 2010Configuring DHCP Server Parameters Section 3.4.12.10.4.2.1Updated default value of opt60. February 2010Specifying DHCP Proxy Configuration Parameters Section 3.4.12.10.4.3.1Updated default value of opt60. February 2010Configuring the DHCP Relay Parameters Section 3.4.12.10.4.4.1Updated Description, Presence and Default Value of server-addr.February 2010Configuring Classification Rules Section 3.4.12.11.4Updated and corrected the sections related to L2 classifiers.February 2010Managing the Baseband Bandwidth Parameter Section 3.9.11A bandwidth of 7 MHz is not applicable for ODUs in the 2.x GHz band.February 2010Configuring Authentication Parameters Section 3.9.14.1Alarms associated with suspendedeapprocthrshld and maxeaproundsthrshld are not supportedFebruary 2010Configuring ODU Ports Section 3.7.2Tx power resolution updated to 1 dBm April 2010Operation and Administration of the Micro BTS Chapter  4New chapter April 2010Configuring Performance Data Collection Section 3.4.14Updated section content, updated supported counters groups.April 2010Managing MSs for Specific MS Advanced Mode Data CollectionRemoved (feature not supported) April 2010Monitoring Software Components Removed (display of real-time counters not supported by CLI)April 2010Displaying Statistics for Physical and IP InterfacesRemoved (display of real-time counters not supported by CLI)April 2010Managing Power Control Parameters Section 3.9.4Removed: power-control-correction-factorAdded: allowed-if-levelApril 2010Topic Description Date Issued
Document History4Motion xxxii  System ManualDisplaying the VLAN Translation Entries Section 3.4.2.1.7Updated command syntax April 2010Managing Beam Forming Parameter Section 3.9.26New feature April 2010Configuring Alarm Threshold Parameters Section 3.9.20.1Updated description and default value of ul-99prcntnoise.May 2010Configuring General Configuration Parameters for the GPS Section 3.4.16.2.2Added Lassen option to the Type parameter May 2010ODUs Section 1.5.3Updated all power consumption specifications May 2010Operating Humidity Section 1.5.9Updated specifications for outdoor units May 2010Macro Outdoor BTS Section 1.5.10.2Updated unit’s dimensions and weights May 2010ODUs Section 1.5.3Updated weights May 2010Mechanical and Electrical, Macro Indoor BTS Section 1.5.10.1Updated weights of Shelf, AVU, PIU, NPU, AUMay 2010Configuring Logging Section 3.4.13Updated severity levels for module level logging (Alert, Error and Info levels are supported)June 2010Displaying the Current Log Destination Section 3.4.13.1.4Updated display format June 2010Displaying the Current Status of Trace Destinations Section 3.12.1.1.3Updated display format June 2010Configuring the Unique Identifier Section 3.4.16.8.1Updated range for site id June 2010Testing Connectivity to an IP Interface Section 3.4.2.3.8New command (ping test) June 2010Resetting the system Section 3.3.2.1Updated command syntax and command modeJune 2010Topic Description Date Issued
Document History4Motion xxxiii  System ManualConfiguring Parameters for the PHS Rule Section 3.4.12.12.2Corrected definition for verify (in Possible Values)Displaying System-level Logs Section 3.4.13.1.3Updated command syntaxConfiguring the Position Section 3.4.16.2.5Updated command syntaxManaging Neighbor BSs, Section 3.9.9In General: Removed srvcsupport, added bsNeighborBsDlDataMIMOModeConfiguring Feedback Allocation Parameter Section 3.9.5.1In current release actual value of ir-cdma is always 2Configuring Airframe MIMO Parameters Section 3.9.12.2.7Limitations in functionality of first-zone-min-size and first-zone-max-sizeConfiguring Airframe Map Zone Parameters Section 3.9.12.2.2Updated description of majorgrps.Topic Description Date Issued
Legal Rights4Motion xxxiv  System ManualLe gal Rights© Copyright 2010 Alvarion Ltd. All rights reserved.The material contained herein is proprietary, privileged, and confidential and owned by Alvarion or its third party licensors. No disclosure thereof shall be made to third parties without the express written permission of Alvarion Ltd.Alvarion Ltd. reserves the right to alter the equipment specifications and descriptions in this publication without prior notice. No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty.Trade NamesAlvarion®, BreezeCOM®, WALKair®, WALKnet®, BreezeNET®, BreezeACCESS®, BreezeLINK®, BreezeMAX®, BreezeLITE®, BreezePHONE®, 4Motion®, and/or other products and/or services referenced here in are either registered trademarks, trademarks or service marks of Alvarion Ltd.All other names are or may be the trademarks of their respective owners.“WiMAX Forum” is a registered trademark of the WiMAX Forum. “WiMAX,” the WiMAX Forum logo, “WiMAX Forum Certified”, and the WiMAX Forum Certified logo are trademarks of the WiMAX Forum.Statem ent of ConditionsThe information contained in this manual is subject to change without notice. Alvarion Ltd. shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this manual or equipment supplied with it.Wa rranties a nd Discla ime rsAll Alvarion Ltd. (“Alvarion“) products purchased from Alvarion or through any of Alvarion's authorized resellers are subject to the following warranty and product liability terms and conditions.Exclusive Wa rranty(a) Alvarion warrants that the Product hardware it supplies and the tangible media on which any software is installed, under normal use and conditions, will be free from significant defects in materials and workmanship for a period of fourteen (14) months from the date of shipment of a given Product to Purchaser (the "Warranty Period"). Alvarion will, at its sole option and as Purchaser's sole remedy, repair or replace any defective Product in accordance with Alvarion' standard R&R procedure.
Legal Rights4Motion xxxv  System Manual(b) With respect to the Firmware, Alvarion warrants the correct functionality according to the attached documentation, for a period of fourteen (14) month from invoice date (the "Warranty Period")". During the Warranty Period, Alvarion may release to its Customers firmware updates, which include additional performance improvements and/or bug fixes, upon availability (the "Warranty"). Bug fixes, temporary patches and/or workarounds may be supplied as Firmware updates. Additional hardware, if required, to install or use Firmware updates must be purchased by the Customer. Alvarion will be obligated to support solely the two (2) most recent Software major releases. ALVARION SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY PURCHASER'S OR ANY THIRD PERSON'S MISUSE, NEGLIGENCE, IMPROPER INSTALLATION OR IMPROPER TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING OR OTHER HAZARD.Disclaime r(a) The Software is sold on an "AS IS" basis. Alvarion, its affiliates or its licensors MAKE NO WARRANTIES, WHATSOEVER, WHETHER EXPRESS OR IMPLIED, WITH RESPECT TO THE SOFTWARE AND THE ACCOMPANYING DOCUMENTATION. ALVARION SPECIFICALLY DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT WITH RESPECT TO THE SOFTWARE. UNITS OF PRODUCT (INCLUDING ALL THE SOFTWARE) DELIVERED TO PURCHASER HEREUNDER ARE NOT FAULT-TOLERANT AND ARE NOT DESIGNED, MANUFACTURED OR INTENDED FOR USE OR RESALE IN APPLICATIONS WHERE THE FAILURE, MALFUNCTION OR INACCURACY OF PRODUCTS CARRIES A RISK OF DEATH OR BODILY INJURY OR SEVERE PHYSICAL OR ENVIRONMENTAL DAMAGE ("HIGH RISK ACTIVITIES"). HIGH RISK ACTIVITIES MAY INCLUDE, BUT ARE NOT LIMITED TO, USE AS PART OF ON-LINE CONTROL SYSTEMS IN HAZARDOUS ENVIRONMENTS REQUIRING FAIL-SAFE PERFORMANCE, SUCH AS IN THE OPERATION OF NUCLEAR FACILITIES, AIRCRAFT NAVIGATION OR COMMUNICATION SYSTEMS, AIR TRAFFIC CONTROL, LIFE SUPPORT MACHINES, WEAPONS SYSTEMS OR OTHER APPLICATIONS REPRESENTING A SIMILAR DEGREE OF POTENTIAL HAZARD. ALVARION SPECIFICALLY DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR HIGH RISK ACTIVITIES.(b) PURCHASER'S SOLE REMEDY FOR BREACH OF THE EXPRESS WARRANTIES ABOVE SHALL BE REPLACEMENT OR REFUND OF THE PURCHASE PRICE AS SPECIFIED ABOVE, AT ALVARION'S OPTION. TO THE
Legal Rights4Motion xxxvi  System ManualFULLEST EXTENT ALLOWED BY LAW, THE WARRANTIES AND REMEDIES SET FORTH IN THIS AGREEMENT ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING BUT NOT LIMITED TO WARRANTIES, TERMS OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, SATISFACTORY QUALITY, CORRESPONDENCE WITH DESCRIPTION, NON-INFRINGEMENT, AND ACCURACY OF INFORMATION GENERATED. ALL OF WHICH ARE EXPRESSLY DISCLAIMED. ALVARION' WARRANTIES HEREIN RUN ONLY TO PURCHASER, AND ARE NOT EXTENDED TO ANY THIRD PARTIES. ALVARION NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS.Limitation of Lia bility(a) ALVARION SHALL NOT BE LIABLE TO THE PURCHASER OR TO ANY THIRD PARTY, FOR ANY LOSS OF PROFITS, LOSS OF USE, INTERRUPTION OF BUSINESS OR FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY KIND, WHETHER ARISING UNDER BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY OR OTHERWISE AND WHETHER BASED ON THIS AGREEMENT OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.(b) TO THE EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL THE LIABILITY FOR DAMAGES HEREUNDER OF ALVARION OR ITS EMPLOYEES OR AGENTS EXCEED THE PURCHASE PRICE PAID FOR THE PRODUCT BY PURCHASER, NOR SHALL THE AGGREGATE LIABILITY FOR DAMAGES TO ALL PARTIES REGARDING ANY PRODUCT EXCEED THE PURCHASE PRICE PAID FOR THAT PRODUCT BY THAT PARTY (EXCEPT IN THE CASE OF A BREACH OF A PARTY'S CONFIDENTIALITY OBLIGATIONS).Ra dio Frequency Inte rfere nc e State me ntThe Base Transceiver Station (BTS) equipment has been tested and found to comply with the limits for a class A digital device, pursuant to ETSI EN 301 489-1 rules and Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial, business and industrial environments. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user's own expense.
Legal Rights4Motion xxxvii  System ManualFCC Ra diat ion Ha zard Wa rning To comply with FCC RF exposure requirements in Section 1.1307 and 2.1091 of FCC Rules, the antenna used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 2 meter from all persons.R& T TE Com pliance  St atem entThis equipment complies with the appropriate essential requirements of Article 3 of the R&TTE Directive 1999/5/EC.Sa fe ty Conside rat ions - Ge ne ralFor the following safety considerations, "Instrument" means the BreezeMAX units' components and their cables.GroundingBTS chassis, Power Feeders and Outdoor Units are required to be bonded to protective grounding using the bonding stud or screw provided with each unit. Sa fe ty Conside rat ions - DC Pow e red Equipm ent  (BT S &  Pow e r Fe eder)Restricted Access Area: The DC powered equipment should only be installed in a Restricted Access Area.Installation Codes: The equipment must be installed according to the latest edition of the country national electrical codes. For North America, equipment must be installed in accordance with the US National Electrical Code and the Canadian Electrical Code.Overcurrent Protection: A readily accessible Listed branch circuit overcurrent protective device, rated 60A for the Macro BTS or 20A for the Power Feeder or 10A for the Micro BTS, must be incorporated in the building wiring.CAUTION: This equipment is designed to permit connection between the earthed conductor of the DC supply circuit and the grounding conductor at the equipment. See installation instructions.CAUTION ATTENTIONRisk of electric shock and energy hazard.Disconnecting one Power Interface Unit (PIU) disconnects only one PIU module. To isolate the BTS completely, disconnect both PIUsRisque de décharge électrique et d'electrocution. La déconnection d'un seul module d'alimentation (PIU) n'isole pas complètement la Station de Base. Pour cela, il faut impérativement débrancher les deux modules d'alimentation (PIU).
Legal Rights4Motion xxxviii  System ManualThe equipment must be connected directly to the DC Supply System grounding electrode conductor.All equipment in the immediate vicinity must be grounded in the same way, and not be grounded elsewhere.The DC supply system is to be local, i.e. within the same premises as the equipment.There shall be no disconnect device between the grounded circuit conductor of the DC source (return) and the point of connection of the grounding electrode conductor.Lithium  Batt er yThe battery on the NPU card is not intended for replacement.Ca ut ionTo avoid electrical shock, do not perform any servicing unless you are qualified to do so.Line  Volta geBefore connecting this instrument to the power line, make sure that the voltage of the power source matches the requirements of the instrument.Ra dioThe instrument transmits radio energy during normal operation. To avoid possible harmful exposure to this energy, do not stand or work for extended periods of time in front of its antenna. The long-term characteristics or the possible physiological effects of radio frequency electromagnetic fields have not been yet fully investigated.Outdoor U nits a nd Ant ennas I nsta llat ion a nd GroundingEnsure that outdoor units, antennas and supporting structures are properly installed to eliminate any physical hazard to either people or property. Make sure that the installation of the outdoor unit, antenna and cables is performed in accordance with all relevant national and local building and safety codes. Even where grounding is not mandatory according to applicable regulation and national codes, it is highly recommended to ensure that the outdoor unit and the antenna mast (when using external antenna) are grounded and suitable lightning protection devices are used so as to provide protection against voltage surges and static charges. In any event, Alvarion is not liable for any injury, damage or
Legal Rights4Motion xxxix  System Manualregulation violations associated with or caused by installation, grounding or lightning protection.Disposal of Ele ctronic  a nd Elec tric a l Wast eDisposal of Electronic and Electrical WastePursuant to the WEEE EU Directive electronic and electrical waste must not be disposed of with unsorted waste. Please contact your local recycling authority for disposal of this product.
Important Notice4Motion xl  System ManualImportant  N ot ic eThis user manual is delivered subject to the following conditions and restrictions:This manual contains proprietary information belonging to Alvarion Ltd. Such information is supplied solely for the purpose of assisting properly authorized users of the respective Alvarion products.No part of its contents may be used for any other purpose, disclosed to any person or firm or reproduced by any means, electronic and mechanical, without the express prior written permission of Alvarion Ltd.The text and graphics are for the purpose of illustration and reference only. The specifications on which they are based are subject to change without notice.The software described in this document is furnished under a license. The software may be used or copied only in accordance with the terms of that license.Information in this document is subject to change without notice. Corporate and individual names and data used in examples herein are fictitious unless otherwise noted.Alvarion Ltd. reserves the right to alter the equipment specifications and descriptions in this publication without prior notice. No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty. The information contained herein is merely descriptive in nature, and does not constitute an offer for the sale of the product described herein.Any changes or modifications of equipment, including opening of the equipment not expressly approved by Alvarion Ltd. will void equipment warranty and any repair thereafter shall be charged for. It could also void the user's authority to operate the equipment.Some of the equipment provided by Alvarion and specified in this manual, is manufactured and warranted by third parties. All such equipment must be installed and handled in full compliance with the instructions provided by such manufacturers as attached to this manual or provided thereafter by Alvarion or the manufacturers. Non-compliance with such instructions may result in serious
Important Notice4Motion xli  System Manualdamage and/or bodily harm and/or void the user's authority to operate the equipment and/or revoke the warranty provided by such manufacturer.
About This Manual4Motion xlii  System ManualAbout T his ManualThis manual describes the 4Motion solution, and details how to install, operate and manage the BTS system components.This manual is intended for technicians responsible for installing, setting and operating the 4Motion BTS equipment, and for system administrators responsible for managing the system.This manual contains the following chapters and appendices:Chapter 1 - System description: Describes the 4Motion BTS and its components.Chapter 2 - Installation: Describes how to install the BTS components.Chapter 3 - Commissioning: Describes how to configure basic parameters and validate units' operation.Chapter 4 - Operation and Administration Using the CLI: Describes how to use the Command Line Interface (CLI) for configuring parameters, checking system status and monitoring performance. Appendix A - Antenna Configurations: Describes the proposed antenna configurations that support the different available diversity scenarios.Appendix B - Software Upgrade: Describes how to load new software files using TFTP, and how to switch to a new software version in 4Motion units.Glossary: A listing of commonly used terms.
Contents4Motion xliii  System ManualContentsChapte r 1  - Syst em De scription .............................................................. 11.1 About WiMAX................................................................................................................31.2 4Motion Solution ..........................................................................................................41.2.1 4Motion Solution Highlights.................................................................................41.2.2 WiMAX Network Reference Model......................................................................61.3 The Base Transceiver Station ...................................................................................131.3.1 The Indoor Macro BTS......................................................................................141.3.2 The Macro Outdoor BTS ...................................................................................201.3.3 The Outdoor Micro BTS ....................................................................................211.3.4 ODUs for Macro (Indoor/Outdoor) BTS.............................................................211.3.5 Power Feeder....................................................................................................221.3.6 Antenna.............................................................................................................231.3.7 GPS...................................................................................................................231.4 Element Management Systems.................................................................................251.4.1 AlvariSTAR........................................................................................................251.5 Specifications .............................................................................................................271.5.1 Modem & Radio ................................................................................................271.5.2 Sensitivity (per channel)* ..................................................................................271.5.3 ODUs ................................................................................................................281.5.4 Micro Outdoor BTS ...........................................................................................401.5.5 AU - ODU Communication (Macro BTS)...........................................................411.5.6 Data Communication (Ethernet Interfaces).......................................................411.5.7 Configuration and Management........................................................................42
Contents4Motion xliv  System Manual1.5.8 Standards Compliance, General .......................................................................431.5.9 Environmental ...................................................................................................431.5.10 Mechanical and Electrical .................................................................................441.5.11 Antennas ...........................................................................................................51Chapte r 2  - Comm issioning of t he  Ma cro BT S ...................................... 5 72.1 Initial NPU Configuration...........................................................................................592.1.1 Introduction .......................................................................................................592.1.2 NPU Local Connectivity ....................................................................................592.1.3 Site Connectivity ...............................................................................................592.1.4 Static Route Definition.......................................................................................612.1.5 SNMP Manager Definition.................................................................................612.1.6 Mapping the AU Software Version ....................................................................622.1.7 Site ID Definition ...............................................................................................622.1.8 Saving the Configuration...................................................................................622.2 Completing the Site Configuration Using AlvariSTAR ...........................................632.2.1 Introduction .......................................................................................................632.2.2 Site Configuration..............................................................................................642.2.3 Connectivity Configuration (optional) ................................................................642.2.4 Equipment Configuration...................................................................................642.2.5 ASNGW Configuration ......................................................................................662.2.6 BS Configuration ...............................................................................................682.2.7 Site Sector Configuration ..................................................................................692.2.8 Apply All Changes.............................................................................................70Chapte r 3  - Operat ion and Administ ra t ion of t he Ma cro BTS............... 7 13.1 Using the Command Line Interface ..........................................................................733.1.1 Managing the Macro Outdoor BTS ...................................................................74
Contents4Motion xlv  System Manual3.1.2 Accessing the CLI .............................................................................................753.1.3 Command Modes..............................................................................................783.1.4 Interpreting the Command Syntax ....................................................................793.1.5 Using the CLI ....................................................................................................803.1.6 Managing Users and Privileges ........................................................................833.1.7 Managing Secure Shell (SSH) Parameters.......................................................923.1.8 Managing the Session.......................................................................................943.2 Managing Software Upgrade.....................................................................................993.2.1 Before You Start................................................................................................993.2.2 Upgrading the NPU ...........................................................................................993.2.3 Upgrading the AU............................................................................................1063.3 Shutting Down/Resetting the System ....................................................................1193.3.1 Shutting Down the System..............................................................................1193.3.2 Managing System Reset .................................................................................1203.4 NPU Configuration ...................................................................................................1223.4.1 Managing the IP Connectivity Mode ...............................................................1233.4.2 Configuring Physical and IP Interfaces ...........................................................1263.4.3 Managing the AU Maintenance VLAN ID........................................................1553.4.4 Managing the NPU Boot Mode .......................................................................1563.4.5 Managing the 4Motion Configuration File .......................................................1593.4.6 Batch-processing of CLI Commands ..............................................................1703.4.7 Configuring the CPU .......................................................................................1713.4.8 Configuring QoS Marking Rules......................................................................1773.4.9 Configuring Static Routes ...............................................................................1923.4.10 Configuring ACLs ............................................................................................1963.4.11 Managing the BTS Load Balancing Parameters .............................................227
Contents4Motion xlvi  System Manual3.4.12 Configuring the ASN-GW Functionality...........................................................2303.4.13 Configuring Logging ........................................................................................3853.4.14 Configuring Performance Data Collection.......................................................4023.4.15 Configuring the SNMP/Trap Manager.............................................................4063.4.16 Configuring the 4Motion Shelf.........................................................................4143.5 Managing MS in ASN-GW ........................................................................................4503.5.1 Manual MS De-registration .............................................................................4503.5.2 Displaying MS Information ..............................................................................4513.6 Managing AUs ..........................................................................................................4543.6.1 Enabling the AU Configuration Mode\Creating an AU Object.........................4553.6.2 Configuring AU Parameters ............................................................................4563.6.3 Restoring Default Values for AU Configuration Parameters ...........................4603.6.4 Terminating the AU Configuration Mode.........................................................4623.6.5 Deleting an AU Object.....................................................................................4623.6.6 Displaying Configuration and Status Information for AU Parameters .............4633.7 Managing ODUs........................................................................................................4693.7.1 Configuring ODUs ...........................................................................................4693.7.2 Configuring ODU Ports ...................................................................................4763.8 Managing Antennas .................................................................................................4853.8.1 Enabling the Antenna Configuration Mode\Creating an Antenna ...................4853.8.2 Configuring Antenna Parameters....................................................................4863.8.3 Restoring Default Values for Antenna Parameters .........................................4893.8.4 Terminating the Antenna Configuration Mode ................................................4903.8.5 Deleting an Antenna........................................................................................4903.8.6 Displaying Configuration Information for Antennas.........................................4913.9 Managing BSs...........................................................................................................493
Contents4Motion xlvii  System Manual3.9.1 Enabling the BS Configuration Mode\Creating a BS Object ...........................4963.9.2 Deleting a BS ..................................................................................................4973.9.3 Managing BS General Parameters .................................................................4983.9.4 Managing Power Control Levels .....................................................................5063.9.5 Managing BS Feedback Allocation Parameter ...............................................5193.9.6 Managing Neighbor Advertisement Parameters .............................................5213.9.7 Managing Triggers Parameters.......................................................................5243.9.8 Managing Scan Negotiation Parameters ........................................................5283.9.9 Managing Neighbor BSs .................................................................................5313.9.10 Managing the RF Frequency Parameter.........................................................5563.9.11 Managing the Baseband Bandwidth Parameter..............................................5583.9.12 Managing Airframe Structure Parameters.......................................................5613.9.13 Managing BS Bearer Interface Parameters ....................................................5893.9.14 Managing Authentication Relay Parameters...................................................5923.9.15 Displaying Status Information for Handover Control Parameters ...................5963.9.16 Managing Bearer Traffic QoS Marking Rules .................................................5983.9.17 Managing Control Traffic QoS Marking Rules.................................................6063.9.18 Managing ID-IP Mapping Parameters.............................................................6153.9.19 Managing Ranging Parameters ......................................................................6193.9.20 Managing Alarm Threshold Parameters .........................................................6233.9.21 Managing BS Reserved Parameters...............................................................6283.9.22 Managing the BS Keep-Alive Functionality .....................................................6283.9.23 Managing the BS Idle Mode Parameters ........................................................6323.9.24 Managing Scheduler Parameters....................................................................6343.9.25 Managing the BS ASN-GW Load Balancing Parameters ...............................639
Contents4Motion xlviii  System Manual3.9.26 Managing Beam Forming Parameter ..............................................................6423.10Managing Sectors....................................................................................................6463.10.1 Configuring Sector Parameters.......................................................................6463.10.2 Configuring Sector Association Entries...........................................................6553.11Monitoring HW and SW Components ....................................................................6603.11.1 Monitoring Hardware Components .................................................................6603.11.2 Displaying System Files ..................................................................................6673.12Troubleshooting ......................................................................................................6703.12.1 Configuring Tracing.........................................................................................6703.12.2 Configuring Port Monitoring ............................................................................678Chapte r 4  - Operat ion and Administrat ion of t he  M icro BTS  ............ 68 54.1 Micro BTS System Management.............................................................................6874.2 The Monitor Program ...............................................................................................6884.2.1 Accessing the Monitor Program ......................................................................6884.2.2 Using the Monitor Program .............................................................................6894.3 IP Addresses Configuration ....................................................................................6914.3.1 IP Address Configuration Restrictions ............................................................6914.3.2 IP Subnets.......................................................................................................6914.4 The Main Menu .........................................................................................................6924.5 BTS Menu..................................................................................................................6934.5.1 General ...........................................................................................................6934.5.2 Connectivity.....................................................................................................6944.5.3 Unit Control .....................................................................................................6964.5.4 Management ...................................................................................................7024.6 Sector Menu..............................................................................................................7064.6.1 Sector Definition..............................................................................................706
Contents4Motion xlix  System Manual4.6.2 Sector Association ..........................................................................................7064.7 BS Menu ....................................................................................................................7084.7.1 Add..................................................................................................................7084.7.2 Select ..............................................................................................................7114.8 Equipment Menu ......................................................................................................7354.8.1 AU ...................................................................................................................7354.8.2 Radio...............................................................................................................7364.8.3 Antenna...........................................................................................................7384.9 GPS Menu .................................................................................................................7404.9.1 General Configuration .....................................................................................7404.9.2 Inventory & Statuses .......................................................................................742Appe ndix  A - Se ctor Conne ctions Sc he mes  ...................................... 7 44A.1 Introduction ..............................................................................................................746A.2 Fourth Order Diversity, Beam Forming and MIMO................................................747A.3 Fourth Order Diversity, MIMO .................................................................................748A.3.1 Wide Double Dual slant Array .........................................................................748A.3.2 Narrow Dual Dual Slant Array .........................................................................749A.4 Second Order Diversity ...........................................................................................750A.4.1 Wide Double Single Slant Array (Space and Polarization Diversity)...............750A.4.2 Narrow Dual Slant Array (Polarization Diversity) ............................................751A.4.3 Wide Array, Vertical Polarization Antennas (Space Diversity) ........................752Glossary ...............................................................................................  91 0
1ChapterSystem Description
Chapter 1 - System Description4Motion 2 System ManualIn T his Cha pt e r:“About WiMAX” on page 3“4Motion Solution” on page 4“The Base Transceiver Station” on page 13“Element Management Systems” on page 25“Specifications” on page 27
Chapter 1 - System Description About WiMAX4Motion 3 System Manual1.1 About WiMAXEmanating from the broadband world and using all-IP architecture, mobile WiMAX is the leading technology for implementing personal broadband services. With huge market potential and affordable deployment costs, mobile WiMAX is on the verge of a major breakthrough. No other technology offers a full set of chargeable and differentiated voice, data, and premium video services in a variety of wireless fashions - fixed, portable and mobile - that increase revenue and reduce subscriber churn.WiMAX technology is the solution for many types of high-bandwidth applications at the same time across long distances and will enable service carriers to converge the all-IP-based network for triple-play services data, voice, and video.WiMAX with its QoS support, longer reach, and high data capacity is positioned for fixed broadband access applications in rural areas, particularly when distance is too large for DSL and cable, as well as in urban/suburban areas of developing countries. Among applications for residential are high speed Internet, Voice Over IP telephony and streaming video/online gaming with additional applications for enterprise such as Video conferencing, Video surveillance and secured Virtual Private Network (with need for high security). WiMAX technology allows covering applications with media content requesting more bandwidth.WiMAX allows portable and mobile access applications, with incorporation in notebook computers and PDAs, allowing for urban areas and cities to become “metro zones” for portable and mobile outdoor broadband wireless access. As such WiMAX is the natural complement to 3G networks by offering higher bandwidth and to Wi-Fi networks by offering broadband connectivity in larger areas.The WiMAX Forum is an organization of leading operators and communications component and equipment companies. The WiMAX Forum’s charter is to promote and certify the compatibility and interoperability of broadband wireless access equipment that conforms to the Institute for Electrical and Electronics Engineers (IEEE) 802.16 and ETSI HiperMAN standards. The ultimate goal of the WiMAX Forum is to accelerate the introduction of cost-effective broadband wireless access services into the marketplace. Standards-based, interoperable solutions enable economies of scale that, in turn, drive price and performance levels unachievable by proprietary approaches, making WiMAX Forum Certified products.
Chapter 1 - System Description 4Motion Solution4Motion 4 System Manual1.2 4Motion Solution1.2.1 4Motion Solution HighlightsLeveraging its extensive experience in Broadband Wireless Access (BWA) systems, leading technology and current favorable economics for broadband and mobile services, Alvarion's 4Motion mobile WiMAX solution represents the next evolution in communications.With 4Motion, Alvarion offers a diversified range of products and services for all operators. Integrating the most advanced and adaptive radio management and control technologies, 4Motion optimizes usage of the operator's spectrum and network resources. At the same time, the solution supports the most stringent quality of service (QoS) requirements for next-generation applications such as video and gaming.As a mobile solution, 4Motion network can be efficiently integrated with existing networks, including 3G, DSL, satellite, and cable, to provide multiple service applications.4Motion enables operators and their customers to address the following consumer and enterprise market segments: “Best effort" fixed broadband access (DSL equivalent)Portable broadband access"Personal broadband" (handheld) accessMobile broadband (including full handover and roaming support)4Motion supports the following services:IP-based and Ethernet-based services (e.g. VoIP, video streaming, gaming)QoS and application-based prioritization and de-prioritization4Motion is designed as an end-to-end solution based on the following elements:
Chapter 1 - System Description 4Motion Solution4Motion 5 System ManualBTS (Base Transceiver Station) equipment with an optional localized access service network gateway (ASN-GW):»Indoor modular Macro BTS.»All-outdoor modular Macro BTS.»The all-outdoor single sector Micro BTSOptional centralized, fully integrated ASN-GW, which may be offered as a part of an end-to-end solution that includes third-party partners' equipmentAAA servers provided by either Alvarion or its leading WiMAX partnersAlvariSTAR Element management system supporting NMS and OSS systemsCustomer premises equipment and handsetsFigure 1-1 illustrates the entire service provider environment and 4Motion solution elements within the radio access network, core network and subscriber environment.Figure 1-1: 4Motion Solution Elements
Chapter 1 - System Description 4Motion Solution4Motion 6 System ManualAlvarion believes that compliance with standard-driven open architecture protects the infrastructure investment, and opens the system to a variety of fully interoperable end-user devices. As such, 4Motion is designed with open architecture and interfaces according to the WiMAX Forum networking working group (NWG) profile C, which supports openness and enables flat as well as hierarchical topologies. In addition, by keeping the radio resource management functionality in the Base Transceiver Station only, Profile C delivers a faster, optimized handover mechanism.1.2.2 WiMAX  Net w ork Reference M odelFigure 1-2 and Figure 1-3 show the basic mobile WiMAX network architecture, with a single ASN-GW and with multiple ASN-GWs, as defined by the WiMAX Forum NWG.Figure 1-2: Mobile WiMAX Network Reference Model
Chapter 1 - System Description 4Motion Solution4Motion 7 System Manual The various components and entities involved in the networking architecture are:1.2.2.1 Access Service Network (ASN)An ASN is defined as a complete set of network functions needed to provide radio access to a WiMAX subscriber. The ASN provides the following mandatory functions:WiMAX Layer-2 (L2) connectivity with WiMAX mobile station (MS) Transfer of AAA messages to the WiMAX subscriber's home network service provider (H-NSP) for authentication, authorization and session accounting for subscriber sessionsNetwork discovery and selection of the WiMAX subscriber's preferred NSPRelay functionality for establishing Layer-3 (L3) connectivity with a WiMAX MS (i.e. IP address allocation)Radio resource managementASN-CSN tunnelingASN anchored mobilityFigure 1-3: ASN Reference Model containing Multiple ASN-GWs
Chapter 1 - System Description 4Motion Solution4Motion 8 System ManualAn ASN is comprised of network elements such as one or more base transceiver stations and one or more ASN gateways. An ASN may be shared by more than one connectivity service network (CSN).1.2.2.2 Connectivity Service Network (CSN)A CSN is defined as a set of network functions that provide IP connectivity services to WiMAX subscribers. A CSN may offer the following functions:MS IP address and endpoint parameter allocation for user sessionsInternet accessAAA proxy or serverPolicy and admission control based on user subscription profilesASN-CSN tunneling supportWiMAX subscriber billing and inter-operator settlementWiMAX services such as location-based services, connectivity for peer-to-peer services, provisioning, authorization and/or connectivity to IP multimedia services, and facilities to support lawful intercept services such as those compliant with Communications Assistance Law Enforcement Act (CALEA) proceduresA CSN is comprised of network elements such as routers, proxy/servers, user databases, and inter-working gateway devices.1.2.2.3 Network Access Provider (NAP)An NAP is a business entity that provides WiMAX radio access infrastructure to one or more WiMAX network service providers (NSPs). A NAP implements this infrastructure using one or more ASNs.1.2.2.4 Network Service Provider (NSP)An NSP is a business entity that provides IP connectivity and WiMAX services to WiMAX subscribers compliant with the established service level agreement. The NSP concept is an extension of the Internet service provider (ISP) concept, providing network services beyond Internet access. To provide these services, an NSP establishes contractual agreements with one or more NAPs. An NSP may also establish roaming agreements with other NSPs and contractual agreements with
Chapter 1 - System Description 4Motion Solution4Motion 9 System Manualthird-party application providers (e.g. ASP, ISP) for the delivery of WiMAX services to subscribers. From a WiMAX subscriber standpoint, an NSP may be classified as a home or visited NSP.1.2.2.5 Base Station (BS)The WiMAX BS is an entity that implements the WiMAX MAC and PHY in compliance with the IEEE 802.16e standard. A BS operates on one frequency assignment, and incorporates scheduler functions for uplink and downlink resources.The basic functionality of the BS includes:IEEE 802.16e OFDMA PHY/MAC entityR6 and R8 functionality according to NWG definitions Extensible Authentication Protocol (EAP) relayControl message authenticationUser traffic authentication and encryptionHandover managementQoS service flow management entity1.2.2.6 ASN Gateway (ASN-GW)The ASN-GW is a network entity that acts as a gateway between the ASN and CSN. The ASN functions hosted in an ASN-GW may be viewed as consisting of two groups - the decision point (DP) and enforcement point (EP). The EP includes bearer plane functions, and the DP includes non-bearer plane functions.The basic DP functionality of the ASN-GW includes:Implementation of EAP Authenticator and AAA clientTermination of RADIUS protocol against the selected CSN AAA server (home or visited AAA server) for MS authentication and per-MS policy profile retrieval Storage of the MS policy profileGeneration of authentication key material
Chapter 1 - System Description 4Motion Solution4Motion 10  System ManualQoS service flow authorization entityAAA accounting clientThe basic EP functionality of the ASN-GW includes:Classification of downlink data into generic routing encapsulation (GRE) tunnelsPacket header suppression functionalityDHCP functionalityHandover functionalityThe WIMAX Forum NWG has adopted two different approaches for ASN architecture - centralized and distributed: In the centralized approach there is at least one central ASN-GW, and the NPU operates in transparent mode, as shown in Figure 1-4. Figure 1-4: Centralized Network Reference Model
Chapter 1 - System Description 4Motion Solution4Motion 11  System ManualIn the distributed approach, the NPU operates in ASN-GW mode, as shown in Figure 1-5. Alvarion believes in providing operators with the flexibility to select the mobile WiMAX network topology that best suits their needs and existing network architecture. Therefore, 4Motion is designed to support both distributed and centralized topology approaches according to WiMAX Forum NWG profile C.1.2.2.7 Reference PointsReference point R1 consists of the protocols and procedures between the MS and ASN as per the air-interface (PHY and MAC) specifications (IEEE 802.16e).Reference point R2 consists of protocols and procedures between the MS and CSN associated with authentication, services authorization and IP host configuration management. This reference point is logical in that it does not reflect a direct protocol interface between the MS and CSN. The authentication part of reference point R2 runs between the MS and CSN operated by the home NSP, however, the ASN and CSN operated by the visited NSP may partially process the aforementioned procedures and mechanisms. Reference point R2 might support IP host configuration management running between the MS and CSN (operated by either the home NSP or visited NSP).Figure 1-5: Distributed Network Reference Model
Chapter 1 - System Description 4Motion Solution4Motion 12  System ManualReference point R3 consists of the set of control plane protocols between the ASN and CSN to support AAA, policy enforcement and mobility management capabilities. It also encompasses the bearer plane methods (e.g. tunneling) to transfer user data between the ASN and CSN.Reference point R4 consists of the set of control and bearer plane protocols originating/terminating in various functional entities of an ASN that coordinate MS mobility between ASNs and ASN-GWs. R4 is the only interoperable reference point between similar or heterogeneous ASNs.Reference point R5 consists of the set of control plane and bearer plane protocols for internetworking between the CSN operated by the home NSP and that operated by a visited NSP.Reference point R6 consists of the set of control and bearer plane protocols for communication between the BS and ASN-GW. The bearer plane consists of an intra-ASN data path between the BS and ASN gateway. The control plane includes protocols for data path establishment, modification and release control in accordance with the MS mobility events.Reference point R8 consists of the set of control plane message flows and optional bearer plane data flows between the base stations to ensure a fast and seamless handover. The bearer plane consists of protocols that allow data transfer between base stations involved in the handover of a certain MS. It is important to note that all reference points are logical and do not necessarily imply a physical or even direct connection. For instance, the R4 reference point between ASN-GWs might be implemented across the NAP internal transport IP network, in which case R4 traffic might traverse several routers from the source to the destination ASN-GW.
Chapter 1 - System Description The Base Transceiver Station4Motion 13  System Manual1.3 T he Base Transceive r St ationThe 4Motion solution features a multi-carrier, high-power Base Transceiver Station (BTS). Designed for high availability and redundancy, it utilizes a central networking and management architecture, and a range of diversity schemes. The BTS main features include:R1 support - 802.16e interface handling (e.g. PHY, MAC, CS, Scheduler, ARQ) and processes such as handover, power control and network entry R6 support - communication with ASN-GWEAP proxy in ASN-GW modeHandover triggering for mobility tunnel establishment - R6 (GRE tunnel)Local QoS PEP for traffic via air interface (or SFM) and admission controlHand-Over (HO) control functionRadio resource management agentKey generation (TEK, KEK) and traffic encryptionThe 4Motion Base Transceiver Station equipment includes:The indoor modular Macro BTS.The all-outdoor modular Macro BTS.The all-outdoor single sector Micro BTS.Outdoor Radio Units.GPS ReceiverPower-Feeder (optional for the indoor Macro BTS).
Chapter 1 - System Description The Base Transceiver Station4Motion 14  System Manual1.3.1 T he I ndoor Macro BT S1.3.1.1 The BreezeMAX ShelfThe BreezeMAX shelf is an indoor -48 VDC powered 8U cPCI PICMG 2.x standard shelf prepared for installation in a 19" or 21" (ETSI) rack. This chassis has a total of nine double-Euro (6U high) slots and six single-Euro (3U high) slots. All the modules are hot swappable, and high availability can be provided through multiple redundancy schemes.The shelf modules are:Figure 1-6: BreezeMAX Shelf (with all modules installed)Table 1-1: BreezeMAX Shelf ModulesModule DescriptionPIU 3U high power interface unit, 1+1 redundancy, -48VDC, protection, filtersPSU 3U high power supply unit, up to 3+1 redundancyNPU 6U high network processing unit with optional ASN-GW functionality, hardware ready for 1+1 redundancy (NPU redundancy is not supported in the current release), 1000/100 Base-T main network interface, 1000/100 Base-T cascade interface and 100/10 Base-T out-of-band management interface
Chapter 1 - System Description The Base Transceiver Station4Motion 15  System ManualThe six single-Euro slots are intended for one or two redundant Power Interface Units (PIUs) and up to four redundant Power Supply Units (PSUs). One of the double Euro slots (Slot 5) is dedicated to the NPU module, with interfaces for network backhaul, in-band and out-of-band (OOB) management connections. Another double-Euro slot (Slot 6) is reserved for an optional redundant NPU (the shelf is HW-ready for NPU redundancy). The remaining seven double-Euro slots (1-4, 7-9) are dedicated for Access Unit (AU) modules, thereby enabling various network topologies with up to 6 simultaneously operational AUs, and future redundancy configurations. In addition, the shelf contains an Air Ventilation Unit (AVU).1.3.1.2 NPUThe Network Processing Unit is the controller of the Base Transceiver Station. Serving as the central processing unit that manages the BTS components, the NPU aggregates traffic to/from the AU modules, and transfers it to/from the IP backbone through a dedicated Gigabit/Fast Ethernet interface. In addition, the NPU can be operated in ASN-GW mode, in which case it also implements ASN-GW functionality.When operating in ASN-GW mode, the NPU implements the R3 reference point toward the CSN, R4 reference point toward other ASN-GWs, and R6 reference point toward AU/BSs. The R8 reference point traffic is transparently relayed between AU/BSs (intra- or inter-BTS). When operating in transparent mode, the NPU transparently relays R6 and R8 reference-point traffic between AU/BSs (intra- or inter-BTS). The BreezeMAX shelf is hardware-ready for 1+1 NPU card redundancy. The NPU main functions, when operating in transparent mode, are: Aggregate backbone Ethernet connectivity for user and control traffic Aggregate backbone Ethernet connectivity for management traffic (in-band or out-of-band)Connection to a cascaded shelf (future feature)AU 6U high access unit, 4-channel, 802.16e MAC-modem-baseband IF cardAVU 2U high air ventilation unit, 9+1 redundancy fans with alarm controlTable 1-1: BreezeMAX Shelf ModulesModule Description
Chapter 1 - System Description The Base Transceiver Station4Motion 16  System ManualL2 switch forwarding capabilitiesInternal and external traffic VLAN encapsulationQoS markingOverall operation, control and shelf management, including AU diagnostics and control, PSU monitoring, AVU management and redundancy supportLocal and remote extensive management support via CLI (Telnet, SSH) and SNMP, including software download, fault and performance managementAlarm management, including external alarm inputs and activation of external devicesSynchronization, including GPS receiver interface, clock and IF reference generation and distribution to the shelf modules, and holdover handling Security functionalities such as rate limiting and access control listsWhen operating in ASN-GW mode, the following additional ASN-GW functions are supported: EAP authenticatorRADIUS AAA clientAAA accounting clientMS policy profile storageQoS service flow authorizationClassification of downlink data into service flowsPacket header suppression functionalityMultiple service provider support (multihost) for improved security and wholesale modelDHCP functionality - internal server, DHCP proxy, DHCP relay (with Option 82 support)
Chapter 1 - System Description The Base Transceiver Station4Motion 17  System ManualHandover functionalityGRE encapsulation/decapsulationIP-in-IP encapsulation/decapsulationTransparent VLAN (single tag) and QinQ (dual tag) encapsulationFragmentation/reassemblyR4/R6/R3 interfaces implementationKeep-alive signaling towards the relevant BSs and other ASN-GWs for enhanced management of service availabilityWhen several shelves are collocated, the NPU cascade interface can be used for shelf interconnection. In this architecture, the NPU that is directly connected to the backhaul implements a layer-2 connection toward the NPUs in the cascaded shelves. Bearer, control and management traffic is sent over the cascade connection. Synchronization and GPS backup power are sent toward the NPUs in the cascaded shelves through the GPS/SYNC ports.GPS synchronization cascading will be implemented in a future release.1.3.1.3 AUThe Access Unit module performs the WiMAX/IEEE 802.16e BS function according to the NWG Profile C definitions via digital signal processors (DSPs) and field-programmable gate array (FPGA) technology. The AU module is designed to support high-traffic throughput and enable diversity, MIMO and AAS, thereby extending capacity and range. The AU implements the following functionality:802.16e multi-channel OFDMA PHYUp to four-channel support (Tx/Rx)Diversity and future AAS Flexible channel bandwidth - up to 20 MHzFlexible FFT size - up to 2048 points
Chapter 1 - System Description The Base Transceiver Station4Motion 18  System ManualWide variety of reuse patternsAdvanced channel coding (CTC)HARQRate adaptationHigh-performance CDMA detectorIF interface to RF ODUMAC-PHY interfaceLink management (network entry, basic capabilities negotiation, authentication and registration, connection management)Fragmentation/ reassemblyQoS PEP for air interface trafficQoS DSCP markingScheduling - connections quota computation for all data delivery types Frame/burst buildingPower saveHandover managementPower controlR1/R6/R8 functionalityData path mapping between R6 (GRE) and 802.16e interfacesTraffic authentication and encryptionAuthentication relay Security key receiver
Chapter 1 - System Description The Base Transceiver Station4Motion 19  System ManualContext client/server ID to IP address resolution for ASN entitiesIP and Ethernet convergence sublayersKeep-alive signaling towards the relevant ASN-GWs for enhanced management of service availabilityThe AU design is based on Alvarion's programmable, off-the-shelf, cutting-edge components, in order to provide a future-proof solution with excellent cost and performance.The AU card interfaces with the NPU card for R6/R8 functionality, as well as control, synchronization and management between the NPU and AU.The AU implements four receive and transmit channels, each of them is HW-ready for up to 20 MHz bandwidth.1.3.1.4 PIUThe single-Euro Power Interface Unit module serves as the interface between the DC power source and both the PSU modules and external ODU radio transceivers.The PIU filters and stabilizes the input power, and protects the system from power problems such as over-voltage, surge pulses, reverse polarity connection, and short circuits. It filters high-frequency interference (radiated emissions) and low-frequency interference (conducted emissions) at the external power source. Each shelf contains two slots for optional 1+1 PIU redundancy. One PIU is sufficient to support a fully populated shelf, and two modules provide redundant power feeding (i.e. from two input sources), while avoiding current flow between the two input sources.1.3.1.5 PSUThe single-Euro Power Supply Unit module is a -48 VDC power supply unit that generates low-voltage DC output to comply with PICMG 2.x standard requirements. Each shelf can contain up to four PSU modules supporting N+1 redundancy configuration scheme.Table 1-2 displays the number of PSU modules (excluding redundant units) required for various Base Station configurations without NPU redundancy (one NPU):
Chapter 1 - System Description The Base Transceiver Station4Motion 20  System Manual1.3.1.6 AVUThe 2U-high AVU includes a 1U-high integral chamber for inlet airflow and a 1U-high fan tray with an internal alarm module. To support high availability, the fan tray includes 10 brushless fans (9 fans are sufficient for cooling a fully-loaded shelf). Fan failure is indicated by both the front panel LEDs and a trap sent to the management system. To further support high availability, the chassis may operate without the hot-swappable fan tray for up to 10 minutes until the AVU is replaced.1.3.2 T he M acro Out door BTSThe Macro Outdoor BTS is a modular scalable and reliable all-outdoor platform enabling extended and flexible installation capabilities while sustaining all the features and capabilities of the 4Motion solution.The All-Outdoor Macro BTS portfolio includes the following system elements:NAU (Network Access Unit): A full-size enclosure containing NPU and AU cards.DAU (Dual Access Unit): A full-size enclosure containing two AU cards.SAU (Single Access Unit): A half-size enclosure containing one AU card.The full-size enclosure is similar to the enclosure of the 4x2 ODUs (see Section 1.3.4), supporting flexible mounting options for system components, including back-to-back and side-by-side mounting. The units are available with either full (4-channels) AUs or with 2-channels AUs.The modular architecture and different unit types enable building a variety of configurations using up to six AUs with either 2 or 4 channels, addressing a pay-as-you-grow deployment. The functionality is the same as described for the NPU (see Section 1.3.1.2) and AU (see Section 1.3.1.3) cards of the Indoor Macro BTS, with a few minor exceptions.Table 1-2: PSU Requirements, Configurations with one NPU (excluding PSU redundancy)Number of AUs Minimum Required Number of PSUs1 - 4 25 - 6 3
Chapter 1 - System Description The Base Transceiver Station4Motion 21  System Manual1.3.3 T he Outdoor Mic ro BTSMicro Outdoor BTS is a full-outdoor small form factor WiMAX Base Transceiver Station. The Micro Outdoor BTS complements Macro BTS deployments providing white spots coverage, cell extension and capacity boost. It provides excellent cost/performance in addressing low dense population areas (rural & suburban). It also provides an effective solution for installation constrained areas through light-pole, roof-top or wall mount options. The Micro BTS comprises a single BS and two integrated radios connected to an external dual-slant antenna. The functionality of the Micro BTS is very similar to that of a two-channel NAU unit (an NPU with a single two-channel AU) operating with an external ASN-GW (Centralized architecture).Micro BTS systems are currently available in the 2.5 GHz and 3.5 GHz bands.1.3.4 ODU s for M ac ro (Indoor/Outdoor) BTSThe outdoor unit (ODU) is a high-power, multi-carrier radio unit that connects to one or more external antennas. It is designed to provide high system gain and interference robustness utilizing high transmit power and low noise figure. It is HW-ready for supporting a bandwidth of up to 20 MHz for the 4x2 ODUs and 30 MHz for the 2x2 ODUs, enabling future options such as increased capacity through the use of a multiplexer or wider frequency channels.The following ODU port configurations will be available:1x1(1Rx by 1 Tx): One receive port, one transmit port (one Tx/Rx interface)2x2 (2Rx by 2Tx): Two receive ports, two transmit ports (two Tx/Rx interfaces)4x2 (4Rx by 2Tx): Four receive ports, two transmit ports (two Tx/Rx interfaces, two Rx only interfaces)The wide range of ODU types will enable efficient utilization of various second and fourth order transmit and receive diversity schemes. Some of the 4x2 and all 2x2 ODUs support Beam Forming capabilities for enhanced performance.The following table provides details on the currently available ODUs following the WiMAX Forum’s definitions:
Chapter 1 - System Description The Base Transceiver Station4Motion 22  System Manual1.3.5 Pow er Fee derThe PIU of the indoor Macro BTS can support a maximum current of 58 A (@-40.5 VDC). In certain installations with a relatively high number of ODUs this current may not be sufficient to power the shelf and all the ODUs. In such installations the ODU Power Feeder is used as an additional power source providing power (-48 VDC) to ODUs. It transfers transparently all signals between the AU and the ODU, while injecting DC power received from an external source. Each ODU Power Table 1-3: ODU TypesBand (GHz)ODU Frequency Range (MHz)ODU Port ConfigurationODU Bandwidth (MHz)ODU Max Tx Power (dBm)BF Support2.3 2300-2360 1Rx by 1Tx Up to 10 36 No2340-2400 1Rx by 1Tx Up to 10 36 No2305 - 2317, 2348 - 2360 (includes WCS filter)1Rx by 1Tx Up to 10 36 No2300-2400 2Rx by 2Tx Up to 30 38 Yes2.5 2496-2602 (band A) 1Rx by 1Tx Up to 10 36 No2590-2690 (band B) 1Rx by 1Tx Up to 10 36 No2485-2690 2Rx by 2TX Up to 30 38 Yes2496-2602 (band A) 4Rx by 2Tx Up to 20 38 No2590-2690 (band B) 4Rx by 2Tx Up to 20 38 No2485-2690  4Rx by 2Tx Up to 20 38 Yes2560-2570 4Rx by 2Tx Up to 10 37 No3.3 3300-3355 1Rx by 1 Tx Up to 14 32 No3345-3400 1Rx by 1Tx Up to 14 33 No3.5 3400-3455 1Rx by 1Tx Up to 14 34 No3445-3500 1Rx by 1Tx Up to 14 34 No3500-3555 1Rx by 1Tx Up to 14 34 No3545-3600 1Rx by 1Tx Up to 14 34 No3400-3600 2Rx by 2Tx Up to 30 37 Yes3400-3600 4Rx by 2Tx Up to 20 37 No3400-3600 4Rx by 2Tx Up to 20 37 Yes3.6 3650-3700 1Rx by 1Tx Up to 14 22 No3600-3800 4Rx by 2Tx Up to 20 36 Yes
Chapter 1 - System Description The Base Transceiver Station4Motion 23  System ManualFeeder unit can serve up to four ODUs. Up to three ODU Power Feeder units can be installed in a 1U high Power Feeder panel.1.3.6 Ant ennaIn the 4Motion architecture, the antenna is approached as an independent element. This provides the operator with the flexibility to select the antennas source according to its supplier policy. To ensure the availability of antennas that complement the 4Motion solution, Alvarion works closely with several antenna suppliers to ensure availability of antennas that comply with its requirements.In cases where the operator prefers other antenna vendors, Alvarion can provide a recommended antenna specification based on the required antennas types.For more information on recommended antenna configurations and required antennas refer to “Sector Connections Schemes” on page 744.1.3.7 GPSGPS is used to synchronize the air link frames of Intra-site and Inter-site located Base Transceiver Stations to ensure that in all Base Stations the air frame will start at the same time, and that all Base Stations will switch from transmit (downlink) to receive (uplink) at the same time. This synchronization is necessary to prevent Intra-site and Inter-site interference and Base stations saturation (assuming that all Base Stations are operating with the same frame size and with the same DL/UL ratio).In order for the system to be synchronized, the GPS have to first acquire at least 4 satellites. After that the GPS reception can be reduced to 1 satellite. If no satellite is received the BTS will go to holdover state where internal clock is provided to synchronize the BTS.1.3.7.1 Outdoor GPS Receiver for the Macro BTSThe all-outdoor GPS Receiver is a pole mountable GPS receiver and antenna in a single environmentally protected enclosure. The receiver is powered from the NPU, and it can be installed at a distance of up to 100m from the NPU. In the BMAX-Timing GPS-OGR model, a special adaptor cable is required between the GPS cable and the NPU. When available, no adaptor cable will be required for the BMAX-4M-GPS.1.3.7.2 GPS Antenna Kit for the Micro BTSThe Micro BTS includes an internal GPS receiver with hold over mechanism in case GPS is lost or satellites synchronization was not reached.
Chapter 1 - System Description The Base Transceiver Station4Motion 24  System ManualAlvarion offers the miniature GPS antenna that can be installed at a distance of up to 3m from the BTS.
Chapter 1 - System Description Element Management Systems4Motion 25  System Manual1.4 Element M a na ge ment SystemsThe end-to-end IP-based architecture of the system enables full management of all components, using standard management tools. An SNMP agent in the NPU implements proprietary MIBs for remote setting of operational modes and parameters of the Base Transceiver Station equipment. Security features incorporated in the equipment restrict the access for management purposes.Alvarion offers the following management tool:1.4.1 AlvariSTARAlvariSTAR is a comprehensive carrier-class Element Management System (EMS) for Alvarion’s Broadband Wireless Access systems. AlvariSTAR is designed for today's most advanced Network Operation Centers (NOCs), providing the network Operation, Administration and Maintenance (OA&M) staff and managers with all the network surveillance, monitoring and configuration and service provisioning capabilities required to effectively manage the network while keeping the resources and expenses at a minimum.AlvariSTAR offers the network's OA&M staff with a unified, scalable and distributable management system. Utilizing distributed client-server architecture, the user is provided with a robust, scalable and fully redundant management system in which all single points of failure can be avoided.AlvariSTAR provides the following management functionality:Device DiscoveryDevice InventoryTopologyFault ManagementConfiguration ManagementService ManagementData CollectionPerformance Monitoring
Chapter 1 - System Description Element Management Systems4Motion 26  System ManualDevice embedded software upgradeBTS duplication and template-based configuration modification of multiple BTS simultaneously.Security ManagementEvent Forwarding to other Network Management Systems.
Chapter 1 - System Description Specifications4Motion 27  System Manual1.5 Spe cifications1.5.1 Modem  &  Ra dio1.5.2 Sensit ivity (per channel)** For second order receive diversity configurations sensitivity is improved by 3 dB.For fourth order receive diversity configurations sensitivity is improved by 6 dB.Table 1-4: General Modem & Radio SpecificationsItem DescriptionOperation Mode TDDChannel Bandwidth 5 MHz7 MHz (not applicable for the 2.x GHz band)10 MHzCentral Frequency Resolution 0.125 MHz (actual configurable frequencies depend on the local radio regulations and allocated spectrum)Modulation OFDM modulation, 1024/512 FFT points;  QPSK, QAM16, QAM64Access Method OFDMAFEC Convolutional Turbo Coding: 1/2, 2/3, 3/4, 5/6Table 1-5: Per Channel Sensitivity, AWGN @ PER=1%Modulation & CodingSensitivity (dBm),  5 MHz BandwidthSensitivity (dBm), 7 MHz BandwidthSensitivity (dBm),  10 MHz BandwidthQPSK 1/2 -97.3 -95.8 -94.2QPSK 3/4 -94.9 -93.4 -91.816QAM 1/2 -92.2 -90.7 -89.116QAM 3/4 -88.3 -86.8 -85.264QAM1/2 -86.8 -85.3 -83.764QAM2/3 -83.0 -81.5 -79.964QAM3/4 -82.2 -80.7 -79.164QAM5/6 -81.0 -79.5 -77.9
Chapter 1 - System Description Specifications4Motion 28  System Manual1.5.3 ODUs1.5.3.1 2.3 GHz Band1.5.3.1.1 2.3 GHz Band 1x1 ODUsTable 1-6: 2.3 GHz Band 1x1 ODUs SpecificationsItem DescriptionFrequency Band ODU-HP-2.3: 2300-2360 MHzODU-HP-2.3-WCS: 2305 - 2317, 2348 - 2360 MHz (includes WCS filter)ODU-HP-2.3b: 2340-2400 MHzPorts Configuration 1x1 (1Rx, 1Tx)Bandwidth Support  Up to 10 MHz, 5 & 10 MHz SAW filtersMaximum Tx Power) 36 dBmTx Power Control Range 10 dB, in 1 dB stepsTx Power Accuracy +/- 1 dBMaximum Input Power @ antenna port  -60 dBm before saturation, -8 dBm before damageNoise Figure 4.6 dB typical, 6.0 dB maximumDimension ODU-HP-2.3-WCS: 329 x 157 x 209 mmOther ODUs: 329 x 157 x 169 mmWeight ODU-HP-2.3-WCS: 8.6 KgOther ODUs: 6.1 KgConnectors ANT: N-Type jack, 50 Ohm, lightning protectedIF: TNC jack, 50 Ohm, lightning protectedPower Source -40.5 to -60 VDC over the IF cable Power Consumption Transmit - 90W maximumReceive - 20W maximum
Chapter 1 - System Description Specifications4Motion 29  System Manual1.5.3.1.2 2.3 GHz Band 2x2 ODU* With the optional external WCS filter, the frequency range is 2305-2315, 2350-2360 MHz, and Tx power is reduced by 1 dB.Table 1-7: 2.3 GHz Band 2x2 ODU SpecificationsItem DescriptionFrequency Band ODU-2300-2400-000N-38-2X2-N-0: 2300-2400 MHz* Ports Configuration 2x2 (2Rx, 2Tx)Bandwidth Support  Up to 30 MHzBeam Forming Support YesMaximum Tx Power) 38 dBm* Tx Power Control Range 10 dB, in 1 dB stepsTx Power Accuracy +/- 1 dBMaximum Input Power @ antenna port -60 dBm before saturation, -8 dBm before damageNoise Figure 4.5 dB typical, 5.5 dB maximumDimension 420 x 340 x 270 mmWeight 17 KgConnectors ANT: 2 x N-Type jack, 50 Ohm, lightning protectedIF: 2 x TNC jack, 50 Ohm, lightning protectedPower Source -40.5 to -60 VDC over the IF cable Power Consumption Transmit - 180W maximumReceive - 40W maximum
Chapter 1 - System Description Specifications4Motion 30  System Manual1.5.3.2 2.5 GHz Band1.5.3.2.1 2.5 GHz Band 1x1 ODUsTable 1-8: 2.5 GHz Band 1x1 ODUs SpecificationsItem DescriptionFrequency Band ODU-HP-2.5A: 2496-2602 MHz (Band A)ODU-HP-2.5B: 2590-2690 MHz (Band B)Ports Configuration 1x1 (1Rx, 1Tx)Bandwidth Support  Up to 10 MHzMaximum Tx Power) 36 dBmTx Power Control Range 10 dB, in 1 dB stepsTx Power Accuracy +/- 1 dBMaximum Input Power @ antenna port -60 dBm before saturation, -8 dBm before damageNoise Figure 4.6 dB typical, 6.0 dB maximumDimension 329 x 157 x 209 mmWeight 6.1 KgConnectors ANT: N-Type jack, 50 Ohm, lightning protectedIF: TNC jack, 50 Ohm, lightning protectedPower Source -40.5 to -60 VDC over the IF cable Power Consumption Transmit - 90W maximumReceive - 20W maximum
Chapter 1 - System Description Specifications4Motion 31  System Manual1.5.3.2.2 2.5 GHz Band 2x2 ODUsTable 1-9: 2.5 GHz Band 2x2 ODUs SpecificationsItem DescriptionFrequency Band ODU-2485-2690-000N-38-2X2-N-0: 2485-2690 MHzPorts Configuration 2x2 (2Rx, 2Tx)Bandwidth Support  Up to 30 MHzBeam Forming Support YesMaximum Tx Power) 38 dBmTx Power Control Range 10 dB, in 1 dB stepsTx Power Accuracy +/- 1 dBMaximum Input Power @ antenna port -60 dBm before saturation, -8 dBm before damageNoise Figure 4.5 dB typical, 5.5 dB maximumDimension 420 x 340 x 270 mmWeight 17 KgConnectors ANT: 2 x N-Type jack, 50 Ohm, lightning protectedIF: 2 x TNC jack, 50 Ohm, lightning protectedPower Source -40.5 to -60 VDC over the IF cable Power Consumption Transmit - 180W maximumReceive - 40W maximum
Chapter 1 - System Description Specifications4Motion 32  System Manual1.5.3.2.3 2.5 GHz Band 4x2 ODUs1.5.3.2.4 Compliance with ETSI RegulationsFor compliance with ETSI regulations for the 2.5 GHz Band A such as limiting the Tx power to a maximum of 33dBm, one of the following must be done:1Use a suitable external filter.2Configure the required ODU type as follows:aIf you use ODU-2496-2602-000-N-38-4x2-N-0: Configure oDU24962602000N334by2EtsiNO as the required type. This will create a “virtual” ODU supporting the frequency range 2496-2602 MHz with a Table 1-10: 2.5 GHz Band 4x2 ODUs SpecificationsItem DescriptionFrequency Band ODU-2496-2602-000N-38-4x2-N-0: 2496-2602 MHz (Band A)ODU-2590-2690-000N-38-4x2-N-0: 2590-2690 MHz (Band B)ODU-2485-2690-000N-38-4X2-N-0: 2485-2690 MHz ODU-2560-2570-000N-37-4X2-N-0: 2560-2570 MHzPorts Configuration 4x2 (4Rx, 2Tx)Bandwidth Support  Up to 20 MHzBeam Forming Support ODU-2485-2690-000N-38-4X2-N-0Maximum Tx Power) 38 dBmFor ODU-2560-2570-000N-37-4X2-N-0: 37 dBm.Tx Power Control Range 10 dB, in 1 dB stepsTx Power Accuracy +/- 1 dBMaximum Input Power @ antenna port -60 dBm before saturation, -8 dBm before damageNoise Figure 4.5 dB typical, 5.5 dB maximumDimension 420 x 340 x 270 mmWeight 17 KgConnectors ANT: 4 x N-Type jack, 50 Ohm, lightning protectedIF: 4 x TNC jack, 50 Ohm, lightning protectedPower Source -40.5 to -60 VDC over the IF cable Power Consumption Transmit - 180W maximumReceive - 50W maximum
Chapter 1 - System Description Specifications4Motion 33  System Manualmaximum Tx power of 33 dBm and without support of beam forming capability.bIf you use ODU-2485-2690-000-N-38-4x2-N-0: Configure oDU24962602000N334by2EtsiBFN0 as the required type. This will create a “virtual” ODU supporting the frequency range 2496-2602 MHz with a maximum Tx power of 33 dBm and support of beam forming capability.cIf you use ODU-2485-2690-000-N-38-2x2-N-0: Configure oDU24962602000N332by2EtsiBFN0 as the required type. This will create a “virtual” ODU supporting the frequency range 2496-2602 MHz with a maximum Tx power of 33 dBm and support of beam forming capability.
Chapter 1 - System Description Specifications4Motion 34  System Manual1.5.3.3 3.3 GHz Band1.5.3.3.1 3.3 GHz Band 1x1 ODUsTable 1-11: 3.3 GHz Band 1x1 ODUs SpecificationsItem DescriptionFrequency Band ODU-3300-3355-000N-32-1x1-N-0: 3300-3355 MHzODU-3345-3400-000N-33-1x1-N-0: 3345-3400 MHzPorts Configuration 1x1 (1Rx, 1Tx)Bandwidth Support  Up to 14 MHzMaximum Tx Power 32 dBmTx Power Control Range 10 dB, in 1 dB stepsTx Power Accuracy +/- 1 dBMaximum Input Power @ antenna port -60 dBm before saturation, -8 dBm before damageNoise Figure 4.5 dB typical, 5.5 dB maximumDimension 329 x 157 x 169 mmWeight 6.1 KgConnectors ANT: N-Type jack, 50 Ohm, lightning protectedIF: TNC jack, 50 Ohm, lightning protectedPower Source -40.5 to -60 VDC over the IF cable Power Consumption Transmit - 90W maximumReceive - 20W maximum
Chapter 1 - System Description Specifications4Motion 35  System Manual1.5.3.4 3.5 GHz Band1.5.3.4.1 3.5 GHz Band 1x1 ODUsTable 1-12: 3.5 GHz Band 1x1 ODUs SpecificationsItem DescriptionFrequency Band ODU-HP-TDD-3.4a: 3400-3455 MHzODU-HP-TDD-3.4b: 3445-3500 MHzODU-HP-TDD-3.5a: 3500-3555 MHzODU-HP-TDD-3.5b: 3545-3600 MHzPorts Configuration 1x1 (1Rx, 1Tx)Bandwidth Support  Up to 14 MHzMaximum Tx Power 34 dBmTx Power Control Range 10 dB, in 1 dB stepsTx Power Accuracy +/- 1 dBMaximum Input Power @ antenna port -60 dBm before saturation, -8 dBm before damageNoise Figure 4.5 dB typical, 5.5 dB maximumDimension 329 x 157 x 169 mmWeight 6.1 KgConnectors ANT: N-Type jack, 50 Ohm, lightning protectedIF: TNC jack, 50 Ohm, lightning protectedPower Source -40.5 to -60 VDC over the IF cable Power Consumption Transmit - 90W maximumReceive - 20W maximum
Chapter 1 - System Description Specifications4Motion 36  System Manual1.5.3.4.2 3.5 GHz Band 2x2 ODUsTable 1-13: 3.5 GHz Band 2x2 ODUs SpecificationsItem DescriptionFrequency Band ODU-3400-3600-000N-37-2x2-N-0: 3400-3600 MHzPorts Configuration 2x2 (2Rx, 2Tx)Bandwidth Support  Up to 30 MHzBeam Forming Support YesMaximum Tx Power) 37 dBmTx Power Control Range 10 dB, in 1 dB stepsTx Power Accuracy +/- 1 dBMaximum Input Power @ antenna port -60 dBm before saturation, -8 dBm before damageNoise Figure 4.5 dB typical, 5.5 dB maximumDimension 420 x 340 x 270 mmWeight 17 KgConnectors ANT: 2 x N-Type jack, 50 Ohm, lightning protectedIF: 2 x TNC jack, 50 Ohm, lightning protectedPower Source -40.5 to -60 VDC over the IF cable Power Consumption Transmit - 180W maximumReceive - 40W maximum
Chapter 1 - System Description Specifications4Motion 37  System Manual1.5.3.4.3 3.5 GHz Band 4x2 ODUsTable 1-14: 3.5 GHz Band 4x2 ODUs SpecificationsItem DescriptionFrequency Band ODU-3400-3600-000N-37-4x2-N-0: 3400-3600 MHzODU-3400-3600-000N-37-4x2-BF-N-0: 3400-3600 MHzPorts Configuration 4x2 (4Rx, 2Tx)Bandwidth Support  Up to 20 MHzBeam Forming Support ODU-3400-3600-000N-37-4x2-BF-N-0Maximum Tx Power) ODU-3400-3600-000N-37-4x2-N-0: 37 dBmODU-3400-3600-000N-37-4x2-BF-N-0: 37 dBmTx Power Control Range 10 dB, in 1 dB stepsTx Power Accuracy +/- 1 dBMaximum Input Power @ antenna port -60 dBm before saturation, -8 dBm before damageNoise Figure 4.5 dB typical, 5.5 dB maximumDimension 420 x 340 x 270 mmWeight 17 KgConnectors ANT: 4 x N-Type jack, 50 Ohm, lightning protectedIF: 4 x TNC jack, 50 Ohm, lightning protectedPower Source -40.5 to -60 VDC over the IF cable Power Consumption Transmit - 180W maximumReceive - 50W maximum
Chapter 1 - System Description Specifications4Motion 38  System Manual1.5.3.5 3.6 GHz Band1.5.3.5.1 3.6 GHz Band 1x1 ODUTable 1-15: 3.6 GHz Band 1x1 ODU SpecificationsItem DescriptionFrequency Band ODU-3650-3700-000N-22-1x1-N-0: 3650-3700 MHzPorts Configuration 1x1 (1Rx, 1Tx)Bandwidth Support  Up to 14 MHzMaximum Tx Power 22 dBmTx Power Control Range 10 dB, in 1 dB stepsTx Power Accuracy +/- 1 dBMaximum Input Power @ antenna port -60 dBm before saturation, -8 dBm before damageNoise Figure 4.5 dB typical, 5.5 dB maximumDimension 315 x 157 x 86 mmWeight 2.9 KgConnectors ANT: N-Type jack, 50 Ohm, lightning protectedIF: TNC jack, 50 Ohm, lightning protectedPower Source -40.5 to -60 VDC over the IF cable Power Consumption Transmit - 32W maximumReceive - 13W maximum
Chapter 1 - System Description Specifications4Motion 39  System Manual1.5.3.5.2 3.6 GHz Band 4x2 ODUTable 1-16: 3.6 GHz Band 4x2 ODU SpecificationsItem DescriptionFrequency Band ODU-3600-3800-000N-36-4x2-N-0: 3600-3800 MHzPorts Configuration 4x2 (4Rx, 2Tx)Bandwidth Support  Up to 20 MHzBeam Forming Support YesMaximum Tx Power) 36 dBmTx Power Control Range 10 dB, in 1 dB stepsTx Power Accuracy +/- 1 dBMaximum Input Power @ antenna port -60 dBm before saturation, -8 dBm before damageNoise Figure 4.5 dB typical, 5.5 dB maximumDimension 420 x 340 x 270 mmWeight 17 KgConnectors ANT: 4 x N-Type jack, 50 Ohm, lightning protectedIF: 4 x TNC jack, 50 Ohm, lightning protectedPower Source -40.5 to -60 VDC over the IF cable Power Consumption Transmit - 180W maximumReceive - 50W maximum
Chapter 1 - System Description Specifications4Motion 40  System Manual1.5.4 Micro Out door BTSTable 1-17: Micro Outdoor BTS SpecificationsItem DescriptionFrequency 2.5 GHz Band: 2485-2690 MHz3.5 GHz Band: 3400-3600 MHzBandwidth Support Up to 20 MHzMaximum Tx Power 36 dBmTx Power Control Range 10 dB, in 1 dB stepsTx Power Accuracy +/- 1 dBMax. Input Power (at antenna port)-40 dBm before saturation-10 dBm before damageDimensions (H x W x D) 511 x 280 x 216 mmWeight (kg) 17.5Power Source -40.5 to -60 VDCConnectors PWR: SAMTEC Mini Fit 6 pins.DATA: RJ-45, lightning protected. Supports Ethernet+PoE Out.GPS: TNC jack, 50 ohm, lightning protected.MON: 3-pin low profile jackANT: 2 x N-Type jack, 50 Ohm, lightning protected.Power Consumption Average:180WPeak: 255W
Chapter 1 - System Description Specifications4Motion 41  System Manual1.5.5 AU - ODU Com munic ation (Macro BTS)1.5.6 Data Comm unic ation (Etherne t I nt erfaces)Table 1-18: AU - ODU CommunicationItem Description IF Frequency Tx: 240 MHzRx: 140 MHzRef Synchronization Frequency 64 MHzBi-Directional Control Frequency 14 MHzIF cable Impedance 50 OhmMaximum IF cable Attenuation  10 dB @ 240 MHz7.5 dB @ 140 MHz8 dB @ 64 MHzMinimum IF cable Shielding Effectiveness 90 dB in the 10-300 MHz bandMaximum IF cable Return Loss 20 dB in the 10-300 MHz bandMaximum IF cable DC Resistance 1x1 ODUs, 2.x GHz 4x2 ODUs: 1.5 Ohm3.x GHz 4x2 ODUs: 1 OhmTable 1-19: Data Communication (Ethernet Interfaces)Item DescriptionStandard Compliance IEEE 802.3 CSMA/CDMacro BTS  NPU Data Port  10/100/1000 Mbps, Full Duplex with Auto NegotiationNPU Management Port  10/100 Mbps, Half/Full Duplex with Auto NegotiationNPU Cascade Port (not applicable for NAU)100/1000 Mbps, Full Duplex with Auto NegotiationAU Calibration Port (not applicable for Macro Outdoor BTS components, not used in current release)10/100 Mbps, Half/Full Duplex with Auto NegotiationMicro BTS Data Port 10/100 Mbps, Half/Full Duplex with Auto Negotiation
Chapter 1 - System Description Specifications4Motion 42  System Manual1.5.7 Configurat ion and ManagementTable 1-20: Configuration and ManagementItem DescriptionOut Of Band (OOB) Management(For Micro only Monitor port is applicable)Telnet via Management portSSH via Management portSNMP via Management portTelnet via Cascade port (not applicable for NAU)SSH via Cascade port (not applicable for NAU)SNMP via Cascade port (not applicable for NAU)Monitor port (serial interface)In Band (IB) Management via Data Port SNMP Tel ne tSSHSNMP Agents SNMP Ver. 2 clientMIB II (RFC 1213), Private MIBsSoftware Upgrade Using TFTP Configuration Upload/Download Using TFTP
Chapter 1 - System Description Specifications4Motion 43  System Manual1.5.8 Standards Complia nc e, Genera l1.5.9 EnvironmentalTable 1-21: Standards Compliance, GeneralType StandardEMC ETSI EN 301 489-1/4FCC Part 15Safety  EN60950-1UL 60950-1Environmental  ETS 300 019:Part 2-1 T 1.2 & part 2-2 T 2.3 for indoor & outdoorPart 2-3 T 3.2 for indoorPart 2-4 T 4.1E for outdoorRadio  ETSI EN 302 326ETSI EN 302 544FCC part 15, part 27, part 25Table 1-22: Environmental SpecificationsType Unit DetailsOperating TemperatureOutdoor units AU-ODU-HP-2.3-WCS: -52°C to 55°CAll other ODUs, Micro Outdoor BTS and Macro Outdoor BTS units: -40°C to 55°COutdoor GPS Receiver and Antennas: -40°C to 85°CIndoor equipment 0°C to 40°COperating HumidityOutdoor units 5%-95%, weather protectedIndoor equipment 5%-95% non condensing
Chapter 1 - System Description Specifications4Motion 44  System Manual1.5.1 0 Me chanical a nd Electric al1U = 44.45 mm (1.75”).1HP = 5.08 mm (0.2”)
Chapter 1 - System Description Specifications4Motion 45  System Manual1.5.10.1 Macro Indoor BTS1.5.10.1.1 BreezeMAX Shelf1.5.10.1.2 AVU1.5.10.1.3 PIU1.5.10.1.4 PSUTable 1-23: BreezeMAX Shelf, Mechanical & Electrical SpecificationsItem DescriptionDimensions 8U ETSI type shelf, 8U x 43.2 x 24 cmWeight 6.5 Kg (including AVU)Table 1-24: AVU, Mechanical & Electrical SpecificationsItem DescriptionDimensions 2U x 84HP x 16 cmWeight 1.64 KgPower Consumption 40W maximum, 23W typicalTable 1-25: PIU, Mechanical & Electrical SpecificationsItem DescriptionDimensions 3U x 5HP x 16 cmWeight 0.35 KgPower Source -40.5 to -60 VDCPower Dissipation 35W maximum (active PIU)Maximum Supplied Current 58A-48V Connector 5 pin/40A D-Type plugTable 1-26: PSU, Mechanical & Electrical SpecificationsItem DescriptionDimensions 3U x 5HP x 16 cmWeight 0.7 KgPower Output 300W maximum output powerEfficiency: 80% minimum
Chapter 1 - System Description Specifications4Motion 46  System Manual1.5.10.1.5 NPU1.5.10.1.6 AUTable 1-27: NPU, Mechanical & Electrical SpecificationsItem DescriptionDimensions 6U x 7HP x 16 cmWeight 0.55 KgPower Consumption 68W maximum, 61W typicalConnectors DATA 100/1000Base-T (RJ-45) with 2 embedded LEDsMGMT 10/100Base-T (RJ-45) with 2 embedded LEDsGPS/SYNC IN 15-pin micro D-Type jackGPS/SYNC OUT 15-pin micro D-Type jackCSCD 100/1000Base-T (RJ-45) with 2 embedded LEDsALRM IN/OUT 25-pin micro D-Type jackMON 3-pin low profile jackTable 1-28: AU, Mechanical & Electrical SpecificationsItem DescriptionDimensions 6U x 7HP x 16 cmWeight 0.95 KgPower Consumption 74W maximum, 66W typicalConnectors ODU1 - ODU4 4 x TNC jack, lightning protectedCAL UNIT 10/100Base-T (RJ-45) with 2 embedded LEDs
Chapter 1 - System Description Specifications4Motion 47  System Manual1.5.10.2 Macro Outdoor BTS1.5.10.2.1 NAU1.5.10.2.2 SAUTable 1-29: NAU, Mechanical & Electrical SpecificationsItem DescriptionDimensions 420 x 340 x 270 mmWeight 17 Kg (excluding mounting kit)Power Source -40.5 to -60 VDCPower Consumption 140W maximumNPU Connectors DATA RJ-45, lightning protectedMNG RJ-45, lightning protectedGPS RJ-45, lightning protectedETH (x5) 5 x RJ-45, lightning protectedSYNC (x3) 3 x RJ-45, lightning protectedAU Connectors POWER SAMTEC Mini Fit 6 pinsIF1-IF4 4 x TNC jack, lightning protectedSYNC -ETH RJ-45, lightning protected (not used)MON RJ-45, lightning protectedTable 1-30: SAU, Mechanical & Electrical SpecificationsItem DescriptionDimensions 420 x 340 x 135 mmWeight 8.5 Kg (excluding mounting kit)Power Source -40.5 to -60 VDCPower Consumption 75W maximumConnectors POWER SAMTEC Mini Fit 6 pinsIF1-IF4 4 x TNC jack, lightning protectedSYNC RJ-45, lightning protectedETH RJ-45, lightning protectedMON Not used
Chapter 1 - System Description Specifications4Motion 48  System Manual1.5.10.2.3 DAU* Master AU is with a SYNC connector (in the Slave AU there is no SYNC connector)1.5.10.3 High-Power AC/DC Power Supply for Micro BTSTable 1-31: DAU, Mechanical & Electrical SpecificationsItem DescriptionDimensions 420 x 340 x 270 mmWeight 17 Kg (excluding mounting kit)Power Source -40.5 to -60 VDCPower Consumption 150W maximumMaster* AU ConnectorsPOWER SAMTEC Mini Fit 6 pinsIF1-IF4 4 x TNC jack, lightning protectedSYNC RJ-45, lightning protectedETH RJ-45, lightning protectedMON Not usedSlave* AU ConnectorsPOWER SAMTEC Mini Fit 6 pinsIF1-IF4 4 x TNC jack, lightning protectedSYNC -ETH RJ-45, lightning protectedMON Not usedTable 1-32: High-Power AC/DC Power Supply SpecificationsItem DescriptionInput Voltage 90 ~ 132 / 180 ~ 264 VAC (selection by switch), 47 ~ 63 Hz.Input AC Current (typical) 8A/115 VAC, 3.2A/230VACEfficiency 89% typicalOutput Voltage 54 VDCOutput Current Up to 10ADimensions (H x W x D) 110 x 303 x 240 mmWeight 4.75 kg
Chapter 1 - System Description Specifications4Motion 49  System Manual1.5.10.4 GPS Receiver for Macro BTS1.5.10.4.1 BMAX-Timing GPS-OGR Specifications1.5.10.4.2 BMAX-4M-GPS Specifications1.5.10.5 GPS Antenna Kit for Micro BTS1.5.10.6 ODU Power FeederTable 1-33: BMAX-Timing GPS-OGR GPS Receiver, Mechanical & Electrical SpecificationsItem DescriptionDimensions Tubular enclosure, 15.5 D x 12.7 H cmWeight 0.363 KgPower Source 12 VDC from the NPUPower Consumption 6W maximumConnector 12-pin round plugTable 1-34: BMAX-4M-GPS Receiver, Mechanical & Electrical SpecificationsItem DescriptionDimensions 8.8 x 10.4 x 16 cm Weight 0.38 KgPower Source 12 VDC from the NPUPower Consumption 2W maximumConnector RJ-45Table 1-35: GPS Antenna Kit for Micro BTS SpecificationsItem DescriptionBasic Miniature Antenna 21 mm high, 60 mm diameter, 50 g, ¾” thru-hole or bracket mount, ROHS compliant, IP 67.28 dB gain, power consumption 15 mA max. @ 3.3 VDC. Cable length (RG-6) up to 3m. Table 1-36: ODU Power Feeder, Mechanical & Electrical SpecificationsItem DescriptionDimensions 15.7 x 14.6 x 3.17 cmWeight 0.6 Kg
Chapter 1 - System Description Specifications4Motion 50  System ManualPower Source -40.5 to -60 VDCPower Dissipation 2W per channelConnectors ODU 1 - ODU 4 4 x TNC jack, lightning protectedIDU 1 - IDU 4 4 x TNC jack, lightning protectedPower 3 pin/20A D-Type plugTable 1-36: ODU Power Feeder, Mechanical & Electrical SpecificationsItem Description
Chapter 1 - System Description Specifications4Motion 51  System Manual1.5.1 1 Antennas1.5.11.1 2.x GHz AntennasTable 1-37: BS-RET-DP-ANT 2.3-2.7 SpecificationsItem DescriptionFrequency Band (MHz) 2300-2700Number of Elements 2Polarization Linear, +/-45°Gain (dB) 17.3 @ 2.4 GHz 18 @ 2.6 GHzAzimuth Beamwidth (degrees) 65Elevation Beamwidth (degrees) 6.5Elevation Side Lobe Level (dB) <-18Maximum Power (W) 250Cross-polarization Discrimination (dB) >15Front-to-Back Ratio (dB) >30Electrical Downtilt Range (degrees) 0-10Remote Electrical Downtilt Support Internal motor, AISG version 2 compliantIsolation Between Ports (dB) >30Return Loss (dB) >15RF Interface Impedance (Ohm) 50RF Connectors 2 x N-Type jackRET Connector 8-pin IEC 60130-9Dimensions (mm) 1060 x 126 x 69Weight (Kg) 6Wind Load (Kg) 0.24 @ 160 km/hMaximum Wind Velocity (km/h) 200
Chapter 1 - System Description Specifications4Motion 52  System ManualTable 1-38: BS-RET-DDP-ANT 2.3-2.7 and BS-EDT-DDP-ANT 2.3-2.7 SpecificationsItem DescriptionFrequency Band (MHz) 2300-2700Number of Elements 4Polarization Linear, 2 x +/-45°Gain (dB) 17.3 @ 2.4 GHz 18 @ 2.6 GHzAzimuth Beamwidth (degrees) 65Elevation Beamwidth (degrees) 6.5Elevation Side Lobe Level (dB) <-18Maximum Power (W) 250Cross-polarization Discrimination (dB) >15Front-to-Back Ratio (dB) >30Electrical Downtilt Range (degrees) 0-10Remote Electrical Downtilt Support BS-RET-DDP-ANT 2.3-2.7: Internal motor, AISG version 2 compliantBS-EDT-DDP-ANT 2.3-2.7: NoneIsolation Between Ports (dB) >30Return Loss (dB) >15RF Interface Impedance (Ohm) 50RF Connectors 4 x N-Type jackRET Connector 8-pin IEC 60130-9Dimensions (mm) 1070 x 300 x 110Weight (Kg) 13Wind Load (Kg) 0.48 @ 160 km/hMaximum Wind Velocity (km/h) 200
Chapter 1 - System Description Specifications4Motion 53  System ManualTable 1-39: ANT.2.3-2.7GHz, D/S,65°,16±0.5dBi SpecificationsItem DescriptionFrequency Band (MHz) 2300-2700Number of Elements 2Polarization Linear, +/-45°Gain (dB) 16 +/- 0.5Azimuth Beamwidth (degrees) 65 +/-5Elevation Beamwidth (degrees) 8 +/-2Elevation Side Lobe Level (dB) <-18Maximum Power (W) 50Cross-polarization Discrimination (dB) -15Front-to-Back Ratio (dB) >28Isolation Between Ports (dB) >25RF Interface Impedance (Ohm) 50RF Connectors 2 x N-Type jacksMechanical Downtilt Range (degrees) 0-15Dimensions (mm) 711 x 171 x 90Weight (Kg) 2.6Maximum Wind Velocity (km/h) Survival: 200Operation: 160Regulatory Compliance ETSI EN 302 326-3 V1.2.1 class CSRoHS Compliance
Chapter 1 - System Description Specifications4Motion 54  System Manual1.5.11.2 3.5 GHz AntennasTable 1-40: BS-RET-DP-ANT 3.3-3.8 SpecificationsItem DescriptionFrequency Band (MHz) 3300-3800Number of Elements 2Polarization Linear, +/-45°Gain (dB) 18Azimuth Beamwidth (degrees) 65Elevation Beamwidth (degrees) 6.5Elevation Side Lobe Level (dB) <-18Maximum Power (W) 200Cross-polarization Discrimination (dB) >15Front-to-Back Ratio (dB) >30Electrical Downtilt Range (degrees) 0-10Remote Electrical Downtilt Support Internal motor, AISG version 2 compliantIsolation Between Ports (dB) >30Return Loss (dB) >15RF Interface Impedance (Ohm) 50RF Connectors 2 x N-Type jackRET Connector 8-pin IEC 60130-9Dimensions (mm) 760 x 126 x 69Weight (Kg) 4.5Wind Load (Kg) 0.17@ 160 km/hMaximum Wind Velocity (km/h) 200
Chapter 1 - System Description Specifications4Motion 55  System ManualTable 1-41: BS-RET-DDP-ANT 3.3-3.8 SpecificationsItem DescriptionFrequency Band (MHz) 3300-3800Number of Elements 4Polarization Linear, 2 x +/-45°Gain (dB) 18Azimuth Beamwidth (degrees) 65Elevation Beamwidth (degrees) 6.5Elevation Side Lobe Level (dB) <-18Maximum Power (W) 200Cross-polarization Discrimination (dB) >15Front-to-Back Ratio (dB) >30Electrical Downtilt Range (degrees) 0-10Remote Electrical Downtilt Support Internal motor, AISG version 2 compliantIsolation Between Ports (dB) >30Return Loss (dB) >15RF Interface Impedance (Ohm) 50RF Connectors 4 x N-Type jackRET Connector 8-pin IEC 60130-9Dimensions (mm) 750 x 300 x 110Weight (Kg) 10.5Wind Load (Kg) 0.34 @ 160 km/hMaximum Wind Velocity (km/h) 200
Chapter 1 - System Description Specifications4Motion 56  System ManualTable 1-42: ANT.3.5GHz, D/S,65°,16±0.5dBi SpecificationsItem DescriptionFrequency Band (MHz) 3300-3800Number of Elements 2Polarization Linear, +/-45°Gain (dB) 16 +/- 0.5Azimuth Beamwidth (degrees) 65 +/-5Elevation Beamwidth (degrees) 6 +/-1Elevation Side Lobe Level (dB) <-14Maximum Power (W) 50Cross-polarization Discrimination (dB) -15Front-to-Back Ratio (dB) >25Isolation Between Ports (dB) >25RF Interface Impedance (Ohm) 50RF Connectors 2 x N-Type jacksMechanical Downtilt Range (degrees) 0-15Dimensions (mm) 711 x 171 x 90Weight (Kg) 2.6Maximum Wind Velocity (km/h) Survival: 200Operation: 160Regulatory Compliance RoHS Compliance
2ChapterCommissioning of the Macro BTS
Chapter 2 - Commissioning of the Macro BTS4Motion 58  System ManualIn T his Cha pt e r:“Initial NPU Configuration” on page 59“Completing the Site Configuration Using AlvariSTAR” on page 63
Chapter 2 - Commissioning of the Macro BTS Initial NPU Configuration4Motion 59  System Manual2.1 Initial NPU Configuration2.1.1 I ntroduct ionAfter completing the installation process, as described in the preceding chapter, some basic NPU parameters must be configured locally using the CLI via the MON port of the NPU.Refer to “Using the Command Line Interface” on page 73 for information on how to access the CLI either via the MON port or via Telnet and how to use it.The following sections describe the minimum mandatory configuration actions required to allow remote configuration of the site and to enable discovery by the EMS system:1”NPU Local Connectivity”2”Site Connectivity”3”Static Route Definition”4”SNMP Manager Definition”5”Mapping the AU Software Version”6”Site ID Definition””Saving the Configuration”2.1.2 NPU Loca l Connectivit yRefer to “Accessing the CLI from a Local Terminal” on page 75 for details on connecting locally to the NPU. Clear existing site configuration (must be executed for "used” NPUs). Restore to factory default and reboot using the following command: npu# restore-factory-defaultThe system will reset automatically.2.1.3 Sit e Connect ivity2.1.3.1 Connectivity ModeThe connectivity mode determines how traffic is to be routed between the NPU and the BSs, AAA server and external Management System servers.
Chapter 2 - Commissioning of the Macro BTS Initial NPU Configuration4Motion 60  System ManualThe default connectivity mode is In-Band (IB) via the Data port. Alternatively, the NPU can be managed Out-Of-Band (OOB) via the dedicated Management port.To view the current and configured connectivity mode, use the command:  npu# show connectivity modeTo change the connectivity mode to Out-Of-Band, use the command: npu(config)# connectivity mode outband (for details refer to “Configuring the IP Connectivity Mode” on page 125).2.1.3.2 VLANs Translation (Inband Connectivity Mode)The Data port operates in VLAN-aware bridging mode (tagged-trunk mode). The values configured for VLAN ID(s) used on this port are the VLAN IDs used internally. These are the VLAN ID for the bearer IP interface (the default is 11) and, in In-Band Connectivity mode, the VLAN ID of the external-management IP interface (the default is 12).When using In-Band connectivity via the Data port, if the value of the VLAN ID used for management in the backbone differs from the value configured for the external-management interface, the external-management VLAN ID should be translated accordingly. It is recommended to configure also VLAN translation for the bearer interface. To enable VLAN translation and configure the required VLANs translation, run the following commands (the examples are for backhaul Data VLAN ID 30 and Management VLAN ID 31, assuming the default VLAN IDs for external-management and bearer interfaces):1Enable the Data port configuration mode (for details refer to “Enabling the Interface Configuration Mode” on page 129): npu(config)# interface gigabitethernet 0/102Enable VLAN translation (for details refer to “Enabling/Disabling VLAN Translation” on page 136): npu(config-if)# vlan mapping enable3Translate external-management VLAN 12 to the backhaul management VLAN 31: npu(config-if)# vlan mapping 12 31 (for details refer to “Creating a VLAN Translation Entry” on page 137)4Translate data VLAN 11 to the backhaul data VLAN 30:  npu(config-if)# vlan mapping 11 30 5Exit the interface configuration mode: npu(config-if)# exit6To view the VLAN mapping parameters, run the command: npu# show interface gigabitethernet 0/10 vlan mapping
Chapter 2 - Commissioning of the Macro BTS Initial NPU Configuration4Motion 61  System Manual2.1.3.3 External Management InterfaceTo configure the necessary parameters of the External Management interface used for connectivity with the EMS system, run the following commands:1Enable the External Management interface configuration mode (for details refer to “Enabling the Interface Configuration Mode” on page 129):  npu(config)# interface external-mgmt (there is no need to shut down the interface for configuring its parameters)2Configure the IP address (x.x.x.x) and subnet mask (y.y.y.y). For details refer to “Assigning an IP address to an interface” on page 146: npu(config-if)# ip address x.x.x.x y.y.y.y 3Exit the interface configuration mode: npu(config-if)# exit4Exit the configuration mode: npu(config)# exit2.1.3.4 Save and Apply Changes in Site Connectivity Configuration1Save the configuration: npu# write (otherwise, after the next time reset you will lose the configuration changes).2If you changed the Connectivity Mode, reset the system to apply the changes: npu# reset2.1.4 Static  Rout e DefinitionStatic Route must be configured whenever the EMS server and the NPU are on different subnets. For more details refer to “Adding a Static Route” on page 193.Run the following command: npu(config)# "ip route x.x.x.x y.y.y.y z.z.z.z"  (x.x.x.x y.y.y.y is the network segment of the EMS server, z.z.z.z is the next-hop IP address that should be in the segment of the external-management interface.2.1.5 SNMP Mana ge r Definit ionTo define the communities to be used by the SNMP manager, run the command:  npu(config)# snmp-mgr ReadCommunity public ReadWriteCommunity private. For more details refer to “Adding an SNMP Manager” on page 406.For proper operation of the manager you should configure also the Trap Manager parameters and enable sending traps to the defined Trap Manager (this can also be done later via the management system):1npu(config)# trap-mgr ip-source x.x.x.x port 162 TrapCommunity public (x.x.x.x is the IP address of the EMS server). For more details refer to “Adding/Modifying a Trap Manager entry” on page 409
Chapter 2 - Commissioning of the Macro BTS Initial NPU Configuration4Motion 62  System Manual2npu(config)# trap-mgr enable ip-source x.x.x.xNote that if the management system is behind a NAT router, the NAT Outside IP address (the IP of the router’s interface connected in the direction of the managed device LAN) must be defined in the device as a Trap Manager, with traps sending enabled. In the NAT router, Port Forwarding (NAT Traversal) must be configured for UDP and TCP ports 161 and 162 from Outside IP (connected to the managed device’s LAN) to Inside IP (connected to the management system’s LAN).2.1.6 Ma pping the AU Softw a re VersionTo define the software version to be used by all AUs run the command: npu(config)# map au default <image name>, where image name is the required AU software version (to view the AU software versions available in the NPU run the command npu# show au image repository).2.1.7 Sit e ID De finitionTo define the site ID (Site Number): npu(config)# site identifier x  (x is the unique site identifier, a number in the range from 1 to 999999)For more details refer to “Configuring the Unique Identifier for the 4Motion Shelf” on page 447.2.1.8 Saving the  ConfigurationTo save the configuration run the command: npu# write (otherwise, after the next time reset you will lose the configuration changes).
Chapter 2 - Commissioning of the Macro BTS Completing the Site Configuration Using AlvariSTAR4Motion 63  System Manual2.2 Completing t he Site Configurat ion Using Alva riSTAR2.2.1 I ntroduct ionAfter completion of the initial configuration you should be able to manage the new Site using AlvariSTAR and continue configuring (at least) all mandatory parameters to enable the necessary services.For details on how to use AlvariSTAR for managing 4Motion sites refer to the AlvariSTAR and 4Motion Device Manager User Manuals.Verify that the Site is included in the list of devices that can be managed by AlvariSTAR. It can be added to the list of managed devices either through the Equipment Manager (by creating a New managed device) or through the Managed Network window (by inclusion in a range to be discovered and activation of the Network Scan Task from the Task Manager).To complete the minimal configuration, open the Site’s Device Manager from the Equipment Manager and perform the following configuration steps:1“Site Configuration” on page 642“Connectivity Configuration (optional)” on page 643“Equipment Configuration” on page 644“ASNGW Configuration” on page 66 (only for Distributed ASNGW topology)5“BS Configuration” on page 686“Site Sector Configuration” on page 697“Apply All Changes” on page 70NOTEThe following sections list the minimum actions that must be performed for completing basic configuration of the Site. Additional parameters may also be configured in order to complete the entire configuration of the Site.After configuring the mandatory parameters in each screen, click on the Apply button. Click Apply even if you did not change any of the screen’s default parameters.In some of the screens in the following sections there are no mandatory parameters but still you must click on the Apply button to activate the default values.
Chapter 2 - Commissioning of the Macro BTS Completing the Site Configuration Using AlvariSTAR4Motion 64  System Manual2.2.2 Sit e Configuration2.2.2.1 General TabASN Topology - the default is Distributed ASNGW. If you change it to Centralized ASNGW click Apply for the device to accept the change.2.2.3 Connec tivit y Configurat ion (optional)2.2.3.1 IP Interface ScreenConfigure the IP address of the Bearer interface:1Change the IP and/or any other parameter value, except VLAN ID.2Click on Apply to accept the changes.2.2.3.2 IP Routing ScreenThe IP Routing screen is used to define the static routes for traffic originating from the NPU.The static route for management traffic was already configured (see “Static Route Definition” on page 61). If necessary (depending on your specific backhaul network) you may configure additional static route(s) for Bearer Traffic and/or Control Traffic. If additional static routes were defined (or if you made any changes in the already configured static route), click on the Apply button.2.2.4 Equipment Configuration2.2.4.1 AUAU entities must be created for all installed AUs (you may create an AU entity also for AUs that are not installed yet).1Right click on the AU node in the Navigation Pane and select Create. The New AU definition window will open. You can also double-click on an empty slot in the Site Equipment View Page to open the New AU window for the selected slot.To create a new AU entity:
Chapter 2 - Commissioning of the Macro BTS Completing the Site Configuration Using AlvariSTAR4Motion 65  System Manual2In the New AU definition window, define the following:»AU number (AU Slot)»Type (in current release only AU 4x4 Modem is applicable)3Click Apply.4Repeat the process for all required AU entities.2.2.4.2 ODUODU entities must be created for all installed ODUs (you may create an ODU entity also for ODUs that are not installed yet).1Right click on the ODU node in the Navigation Pane and select Create. The New ODU definition window will open.2In the New ODU definition window, define the following:»ODU number »ODU Type3Click Apply.4In the ODU General screen of the applicable ODU, in the Ports Configuration section, configure the Tx Power for the relevant Tx/Rx port(s). Click on the Apply button for the device the accept the configuration. 5Repeat the process for all required ODU entities.2.2.4.3 AntennaAntenna entities must be created for all installed and connected antennas (you may create an Antenna entity also for antennas that are not installed/connected yet).1In the Antenna screen, click on the Add New Antenna button.2In the Antenna Parameters section, define Antenna Product TypeTo create a new ODU entity:To create a new Antenna entity:
Chapter 2 - Commissioning of the Macro BTS Completing the Site Configuration Using AlvariSTAR4Motion 66  System Manual3Click Apply.4Repeat the process for all required Antenna entities.2.2.4.4 GPSThe default GPS Type is Trimble. If there is no GPS, the value should be changed to None.Click Apply for the device to accept the change.2.2.5 ASN GW Configuration2.2.5.1 AAA Screen1Configure the following mandatory parameters:»Primary Server IP Address»RADIUS Shared Secret»ASNGW NAS ID2Click Apply for the device to accept the configuration.2.2.5.2 Service Screen2.2.5.2.1 Service Interface TabAt least one Service Interface for data must be defined. If a dedicated management station for CPEs is being used, a suitable Service Interface for management must also be defined.1Click on the Add Service Interface button and configure the following mandatory parameters:»Service Interface Name»Type»Tunnel Destination IP (IP-in-IP Service Interface)»Service VLAN ID (VLAN Service Interface)»Default Gateway IP Address (VLAN Service Interface)NOTEASNGW screens are available only for Distributed ASNGW topology (see also “Site Configuration” on page 64.
Chapter 2 - Commissioning of the Macro BTS Completing the Site Configuration Using AlvariSTAR4Motion 67  System Manual2Click Apply for the device to accept the configuration.2.2.5.2.2 Service Groups TabAt least one Service Group associated with a defined Service Interface for data must be defined. If a dedicated management station for CPEs is being used, a suitable Service Group associated with the defined Service Interface for management must also be defined.1Click on the Add Service Group button and configure at least the following mandatory parameters:»Name»Type»Service Interface Name»DHCP Function Mode»DHCP Own IP Address»External DHCP Server IP Address (Relay mode)»IP Address Pool From (Server mode)»IP Address Pool To (Server mode)»Subnet Mask (Server mode)»DNS Server IP Address (Proxy mode)2Click Apply for the device to accept the configuration.2.2.5.3 SFA Screen -Classification Rules TabCreate the necessary Classification Rule(s) according to the relevant type of traffic, and click Apply.2.2.5.4 Service Profiles At least one Service Profile must be defined and associated with an already defined Service Group.1Right-click on the Service Profile node and select Create. The New Service Profile window is displayed.2Define the Name of the New Service Profile and click Apply.
Chapter 2 - Commissioning of the Macro BTS Completing the Site Configuration Using AlvariSTAR4Motion 68  System Manual3The new Service Profile added to the list of available Service Profiles in the navigation tree. Select it to continue the configuration process.4Click Add in the Service Flow area.5Configure the applicable general parameters of the Service Flow.6Configure the applicable QoS parameters of Service Flow for UL and DL (for Data delivery type=BE it will be Maximum Sustained Traffic Rate and Traffic Priority)7Associate this Service Flow with previously created Classification Rule(s).8Change the Profile Status to Enable9Click Apply for the device to accept the configuration.2.2.6 BS Configuration2.2.6.1 Creating a New BS Entity1Right click on the BS level entry in the Navigation Pane. The New BS definition window will open.2In the New BS definition window, define the following:»BS ID LSB»Operator ID3Click Apply.4Complete the BS configuration as described in the following sections.2.2.6.2 Radio2.2.6.2.1 Basic Screen2.2.6.2.1.1 General Tab1Configure the following mandatory parameters:»Name»Bandwidth»Center FrequencyTo create a new BS entity:
Chapter 2 - Commissioning of the Macro BTS Completing the Site Configuration Using AlvariSTAR4Motion 69  System Manual2Click Apply for the device to accept the configuration.3You will be prompted to properly configure some additional parameters.4Click Apply for the device to accept the configuration.5Select the Radio Advanced screen and click Apply to complete the configuration.2.2.6.3 R6/R8 Bearer Interface2.2.6.3.1 Bearer Tab1Configure the following mandatory parameters:»IP Address»IP Subnet Mask»Default Gateway2Enable/Disable ASN-GW Pools2.2.6.3.2 Authentication Tab1Configure the mandatory Default Authenticator IP Address parameter.2Click Apply for the device to accept the configuration.2.2.7 Sit e Se ctor Configuration1Right click on the Site Sector level entry in the Navigation Pane. The New Site Sector definition window will open.2In the New Site Sector definition window, define the Site Sector Number3Click Apply.To create a new Site Sector entity:
Chapter 2 - Commissioning of the Macro BTS Completing the Site Configuration Using AlvariSTAR4Motion 70  System Manual4At least one Site Sector Association must be defined for each Site Sector. Click on the Add Sector Association button and configure all the parameters in the applicable line of the Sector site Association table:»BS ID LSB»AU Slot Number»AU Port Number»ODU Number»ODU Port Number»Antenna Number»Antenna Port Number5Click Apply for the device to accept the configuration.2.2.8 Apply All ChangesIf you changed any of the parameters that are applied only after reset of the NPU such as ASN Topology or Configured GPS Type (indicated by a pop-up message after applying the change), you must reset the NPU (in the NPU screen select the Reset option in the Shutdown Operation parameter). This will cause also automatic reset of all AUsTo fully apply all the Site Sector configuration changes, reset all the relevant AUs (in the Control tab of each applicable AU screen select the Reset option in the Shutdown Operation parameter). It is not necessary to reset each of the AUs if you reset the NPU.
3ChapterOperation and Administration of the Macro BTS
Chapter 3 - Operation and Administration of the Macro BTS4Motion 72  System ManualIn T his Cha pt e r:“Using the Command Line Interface” on page 73“Managing Software Upgrade” on page 99“Shutting Down/Resetting the System” on page 119“NPU Configuration” on page 122“Managing MS in ASN-GW” on page 450“Managing AUs” on page 454“Managing ODUs” on page 469“Managing Antennas” on page 485“Managing BSs” on page 493“Managing Sectors” on page 646“Monitoring HW and SW Components” on page 660“Troubleshooting” on page 670
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 73  System Manual3.1 Using t he  Com mand Line Interfa c eAll 4Motion system components are managed via the NPU module. The AU is not accessed directly: any configuration change or status enquiry is sent to the NPU that communicates with other system components.The following system management options are available:Accessing the Command Line Interface (CLI) locally via the MON portUsing Telnet/Secure Shell (SSH) to access the CLIThe CLI is a configuration and management tool that you can use to configure and operate the 4Motion system, either locally or remotely, via Telnet/SSH. The following are some administrative procedures to be executed using the CLI:Specifying the boot mode to be used at the next system resetSelecting the connectivity modeShutting down/resetting 4MotionConfiguring and operating 4MotionMonitoring hardware and software componentsExecuting debug proceduresExecuting software upgrade proceduresThis section provides information about:“Accessing the CLI” on page 75“Command Modes” on page 78“Interpreting the Command Syntax” on page 79“Using the CLI” on page 80“Managing Users and Privileges” on page 83
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 74  System Manual“Managing Secure Shell (SSH) Parameters” on page 92“Managing the Session” on page 943.1.1 Ma na ging the M acro Out door BTSThe following section describe the CLI when using it to manage the Indoor Macro BTS equipment. The same CLI is used also to manage the Macro Outdoor BTS equipment, with the following changes:3.1.1.1 CSCD Port and Local ManagementThere is no CSCD port in the Macro Outdoor BTS. Local Management may be supported only on the Management port (in in-band or unified connectivity mode). It should be noted that local management will be blocked if connectivity mode is set to out-of-band.3.1.1.2 Management PortIn the Macro Outdoor BTS the management port is marked MNG, while in the Indoor BTS it is marked MGMT. All references to MGMT port are applicable to the MNG port of the Macro Outdoor BTS.3.1.1.3 AVU, PIU and PSUAVU and its Fans, PIUs and PSUs do not exist in the Macro Outdoor BTS. These shelf components cannot be manage and the status of all the following is indicated as existing and healthy:2 PIUs4 PSUsAVU10 AVU Fans3.1.1.4 Alarm In/Out Connectors and Dry-Contacts ManagementAlarm In-Out connectors do not exist in the Macro Outdoor BTS. All commands related to dry-contact in/out are not applicable.3.1.1.5 Power FeederPower Feeders are not applicable for the Macro Outdoor BTS
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 75  System Manual3.1.1.6 AUsUp to a maximum of six AUs can be supported in the Macro Outdoor BTS. The following table details the mapping of Macro Outdoor BTS AUs to Slot numbers:3.1.1.7 ODUs and AntennasUp to a maximum of 24 ODUs and 24 Antennas can be defined for the Macro Outdoor BTS.3.1.2 Accessing t he  CLIYou can access the CLI, locally, via an ANSI ASCII terminal or PC that is connected via the DATA port of the NPU. You can also use Telnet/SSH to remotely access the CLI.This section describes the procedures for:“Accessing the CLI from a Local Terminal” on page 75“Accessing the CLI From a Remote Terminal” on page 763.1.2.1 Accessing the CLI from a Local Terminal1Use the MON cable to connect the MON connector of the NPU to the COM port of your ASCII ANSI terminal or PC.2Run a terminal emulation program, such as HyperTerminal™.3Set the communication parameters listed in the following table:Table 3-1: Mapping of Macro Outdoor BTS AUs to Slot #AU Slot #AU of NAU 7SAU 1Master AU of DAU 1 3 (This is the AU with the Sync connector)Slave AU of DAU 1 2Master AU of DAU 2 9 (This is the AU with the Sync connector)Slave AU of DAU 2 8To access the CLI via the MON connector:
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 76  System Manual4The login prompt is displayed. (Press Enter if the login prompt is not displayed.) Enter your login ID and password to log in to the CLI.After you provide your login information, the following command prompt is displayed:npu#This is the global command mode. For more information about different command modes, refer to Section 3.1.3.3.1.2.2 Accessing the CLI From a Remote TerminalThe procedure for accessing the CLI from a remote terminal differs with respect to the IP connectivity mode. The Ethernet port and IP interface you are required to configure for enabling remote connectivity is different for each connectivity mode. For more information about connectivity modes, and Ethernet ports and IP interface used for operating the 4Motion system, refer “Managing the IP Connectivity Mode” on page 123.Table 3-2: COM Port ConfigurationParameter ValueBaud rate 115200Data bits 8Stop bits 1Parity NoneFlow control Xon/XoffPort Connected COM portNOTEThe default login ID and password are:Login ID: adminPassword: admin123To access the CLI from a remote terminal, execute the following procedure:
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 77  System Manual1Assign an IP address to the external-management interface. For this, execute the following procedure. (Refer Table 3-9 for more information about the IP interface to be configured for the connectivity mode you have selected). aRun the following command to enable the interface connectivity mode for the external-management interface:npu(config)# interface external-mgmtbRun the following command to assign an IP address to this interface:npu(config-if)# ip address <ip-address> <subnet-mask>2Connect the Ethernet cable to the DATA connector on the front panel of the NPU. (Refer Table 3-9 for more information about the Ethernet port to be used for the connectivity mode you have selected). 3To enable exchange of packets, create IP-level connectivity between the remote machine and the external-management interface. Typically, the DATA port should be connected to a switch port operating in trunk mode, and the remote machine is connected to another port of the same switch that is configured to operate in access mode with the external-management VLAN ID (default is 12).4From the remote terminal, execute the following command to use Telnet/SSH to access the IP address of the external-management interface:telnet <ip address of external-management interface>ssh <ip address of external-management interface>Refer to “Managing Secure Shell (SSH) Parameters” on page 92 for details on managing SSH parameter.5At the prompt, enter your login ID and password.IMPORTANTThe in-band connectivity mode is the default connectivity mode; the DATA port and external-management VLAN are the default Ethernet port and IP interface that are configured for the in-band connectivity mode. The following procedure can be used for accessing the CLI when the in-band connectivity mode is selected. This procedure is identical for all other connectivity modes. However, the Ethernet port, VLAN, and IP interface to be configured will differ for the out-of-band and unified connectivity modes, as listed in Table 3-9.
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 78  System ManualAfter you provide your login information, the following command prompt is displayed:npu#This is the global command mode. For more information about different command modes, refer to Section 3.1.3.3.1.3 Com mand M odesThe CLI provides a number of command modes, some of which are listed in the following table for executing different types of commands:The following table lists the commands to be executed for entering/exiting a particular command mode:NOTEThe default login ID and password are:Login ID: adminPassword: admin123Table 3-3: CLI Command ModesMode Used for... Command PromptGlobal configuration mode Executing all configuration commandsnpu(config)#Global command mode Executing all other commands such as show and delete commandsnpu#Interface configuration mode Executing all commands for configuring physical and IP interfaces.npu(config-if)#Standard/extended ACL mode Executing commands for configuring standard and extended ACLsnpu(config-std-nacl)# npu(config-ext-nacl)# Table 3-4: Commands to Enter/Exit a Command ModeTo... Run the Command... The Command Mode is Now...Enter the global configuration modenpu# config terminal npu(config)#
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 79  System Manual3.1.4 Interpreting t he Command SyntaxThe following table lists the conventions used in the command syntax for all 4Motion commands:Enter the interface configuration modenpu(config)# interface {<interface-type> <interface-id> |internal-mgmt |external-mgmt | bearer | local-mgmt | npu-host | all-au}npu(config-if)# Exit the configuration mode and enter the global command mode.npu(config)# endnpu (config-if)# endnpu#npu#Exit the current configuration mode by one levelnpu (config-if)# exit npu(config)#Table 3-5: Conventions Used in the 4Motion Command SyntaxConvention Description Example{ } Indicates that the parameters enclosed in these brackets are mandatory, and only one of these parameters should be specified.npu(config)# limit {cpu | memory} ([softlimit <limit>]  [hardlimit <limit>])This command is used for specifying the soft and hard limits for memory and CPU utilization. The cpu/memory parameters are enclosed within {} brackets, indicating that their presence is mandatory, and that only one of these parameters is required. ( ) Indicates that one or all parameters enclosed within these brackets are optional. However, the presence of at least one parameter is required to successfully execute this command.npu(config)# limit {cpu | memory} ([softlimit <limit>] [hardlimit <limit>])This command is used for specifying the soft and hard limits for memory and CPU utilization. The softlimit and hardlimit parameters are enclosed within () brackets, indicating that you are required to specify the value of at least one of these parameters to successfully execute this command.Table 3-4: Commands to Enter/Exit a Command Mode
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 80  System Manual3.1.5 Using the CLITo help you use the CLI, this section provides information about:“Using Control Characters” on page 81“Using the CLI Help” on page 81“Using the History Feature” on page 82[ ] Indicates that the parameter enclosed within these brackets is optional.npu(config)# reboot from shadow [<shadow image name>]This command is used to reboot the system with the shadow image. The shadow image name parameter is enclosed with the [ ] brackets, indicating that it is optional. If you do not specify the value of this parameter, the system automatically boots up with the last downloaded shadow image.< > Indicates that the parameter is mandatory and requires a user-defined value (and not a discrete value).npu(config)# load to shadow <shadow image name>This command is used to load the system with a particular shadow image. It is mandatory to specify a value for the shadow image name parameter; otherwise an error is raised by the system. The value of this parameter is not a discrete value; you are required to specify a value for this parameter.| Indicates the OR conditional operator that is used between two or more parameters. The presence of this parameter indicates that only one of the parameters separated by the I conditional parameter should be specified in the command.npu(config)# pm-group enable npu {R6InterfaceTotal | R6InterfaceBs | ProvisionedQOS | R3Interface | LoadBalancing | InitialNe | ServiceFlow}This command is used to specify the group for which performance data collection and storage is to be enabled. The | conditional operator indicates that only one parameter should be specified.NOTEIn this document, all discrete values are specified in boldface, and all user-defined values are not bold.Table 3-5: Conventions Used in the 4Motion Command Syntax
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 81  System Manual“Using Miscellaneous Commands” on page 82“Privilege Levels” on page 823.1.5.1 Using Control CharactersControl characters refer to special characters that you can use to recall or modify previously-executed commands. The following table lists the control characters to be used for executing commands on the CLI:3.1.5.2 Using the CLI HelpThe CLI provides help that you can access while using the CLI. Execute the following command to obtain help for a specific command:help [“<text>”]Specify the command name as the parameter to view help for this command. For example, to obtain help for the show resource limits command, run the following command:npu# help “show resource limits”The help for the show resource limits command is displayed. Table 3-6: Control Characters for Using the CLIPress To...Up/Down arrow keys Scroll the previously executed CLI commands. Press Enter if you want to select and execute a particular command.Right/Left arrow keys Navigate to the right/left of the selected character in a command.Home key Navigate to the first character of a command.End key Navigate to the last character of a command.Backspace key Delete the characters of a command.TAB key Prompt the CLI to complete the command for which you have specified a token command. Remember that the CLI that is the nearest match to the token command that you have specified is displayed.? key View the list of commands available in the current mode. If you press ? after a command, a list of parameters available for that command is displayed.
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 82  System ManualIf you do not provide the command name as the parameter, all commands that can be executed in the current command mode are displayed.3.1.5.3 Using the History FeatureThe history feature of the CLI maintains a sequential list of all previously executed commands. The following table lists the commands that you can run to access, edit or execute a command from the command history list:3.1.5.4 Using Miscellaneous CommandsThe following table lists other miscellaneous commands that you can execute in any mode while using the CLI:3.1.5.5 Privilege LevelsAll commands that can be executed using the CLI are assigned privilege levels between 1 and 10, where 1 is the lowest, and 10 is the highest. In addition, each user is assigned a privilege level; the user can access only those commands for which the privilege level is the same or lower than the user’s privilege level. The default user, admin, is assigned privilege level 10. However, if you are logging in as admin, you can execute certain additional commands for managing users and enabling passwords for privilege levels. For more information about managing users and privileges, refer to Section 3.1.6.Table 3-7: Commands for Using the History FeatureRun the command... To...show history Obtain a list of previously executed commands (up to 14).!! Execute the last command displayed in the list of previously executed commands.!<n> Execute the nth command in the list of previously-executed commands. !<string> Execute the most recent command in the CLI history that starts with the string entered as the value for the string parameter.Table 3-8: Miscellaneous CommandsEnter the command... To...exit Exit the current configuration mode. In global command mode this command will cause termination of the session. clear screen Clear the screen.
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 83  System Manual3.1.6 Ma na ging Use rs and Privile ge sTo enable multi-level access to the CLI, you can create and manage multiple users, and assign privilege levels for each user. The privilege level determines whether a user is authorized to execute a particular command. The privilege level is pre-configured for each command, and can be between 1 and 10, where 1 is the lowest and 10 is the highest. The user can execute all commands for which the privilege level is equal to or lower than the default privilege level assigned to the user.You can also configure passwords for each privilege level. Users with lower privilege levels can enter this password to enable higher privilege levels.This section describes the commands for:“Managing Users” on page 83“Managing Privileges” on page 86“Enabling/Disabling Higher Privilege Levels” on page 88“Displaying Active Users” on page 90“Displaying All Users” on page 91“Displaying the Privilege Level” on page 913.1.6.1 Managing UsersYou can add/modify/delete one or more users for accessing the CLI either through a local or remote terminal.This section describes the commands for:“Adding/Modifying Users” on page 84IMPORTANTBy default, the privilege level of users logging in with admin privileges is 10. However, the admin user can execute some additional commands for adding users and enabling passwords for different privilege levels. IMPORTANTOnly users who have logged in as admin can add/modify/delete users.
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 84  System Manual“Deleting a User” on page 853.1.6.1.1 Adding/Modifying UsersTo add/modify a user, and assign a username, password, and privilege level, run the following command:npu(config)# username <user-name> password <passwd> privilege <1-10>IMPORTANTOnly users who have logged in as admin can execute this task.IMPORTANTAn error may occur if:You are not logged in as the admin.The username or password that you have specified is more than 20 characters.The privilege level that you have specified is not within the range, 1-10.Command Syntaxnpu(config)# username <user-name> password <passwd> privilege <1-10>Privilege Level10Syntax Description Parameter Description Presence Default ValuePossible Valuesusername <user-name>Indicates the user name of the user to be added.Mandatory N/A String (up to 20 characters and case-sensitive)password <passwd>Indicates the password to be assigned to the user to be added.Optional passwordString (up to 20 characters and case-sensitive)
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 85  System Manual3.1.6.1.2 Deleting a UserTo delete a user, run the following command:npu(config)# no user <username>privilege <1-10> Indicates the privilege level to be assigned to a user. The user will be permitted to execute all commands for which the privilege level is equal to or lower than the value of this parameter.Mandatory N/A 1-10Command ModesGlobal configuration modeIMPORTANTOnly users who have logged in as admin can execute this task.IMPORTANTAn error may occur if:You are not logged in as admin user.The username that you have specified does not exist. Remember that user names are case-sensitive.You are trying to delete an active user or the admin user. Command Syntaxnpu(config)# no user <username>Privilege Level10
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 86  System Manual3.1.6.2 Managing PrivilegesTo enable users to execute commands that require a higher privilege level (than their currently configured default level), you can configure a password for each privilege level. Other users can then use the password you have specified to enable a higher privilege level. This section describes the commands for:“Assigning a Password for a Privilege Level” on page 86“Deleting a Password for a Privilege Level” on page 873.1.6.2.1 Assigning a Password for a Privilege LevelTo assign a password for a privilege level, run the following command:npu(config)# enable password  [Level <1-10>] <password> Syntax Description Parameter Description Presence Default ValuePossible Valuesusername <name>Indicates the username of the user to be deleted.Mandatory N/A String (upto 20 characters and case-sensitive)Command ModesGlobal configuration modeIMPORTANTOnly users who have logged in as admin can assign or delete passwords for any privilege level.IMPORTANTOnly users who have logged in as admin can execute this command.IMPORTANTAfter you execute this command, any user can use this password to enable the (higher) privilege level for which you have configured the password. For more information about using passwords for enabling higher privilege levels, refer Section 3.1.6.3.
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 87  System Manual3.1.6.2.2 Deleting a Password for a Privilege LevelTo delete a password for a privilege level, run the following command:npu(config)# no enable password [Level <1-10>]IMPORTANTAn error may occur if:You are trying to configure a password for a privilege level that is higher than your default privilege level.  The password that you have specified is more than 20 characters.The privilege level that you have specified is not within the range, 1-10.Command Syntaxnpu(config)# enable password  [Level <1-10>] <password>Privilege Level10Syntax Description Parameter Description Presence Default ValuePossible Values[Level <1-10>] Indicates the privilege level for which a password is to be enabled.Optional 10 1-10<password> Denotes the password to be assigned for the current privilege level.Mandatory N/A String (up to 20 characters and case-sensitive)Command ModesGlobal configuration modeIMPORTANTOnly users who have logged in as admin can execute this command.
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 88  System Manual3.1.6.3 Enabling/Disabling Higher Privilege LevelsYou can execute commands that require higher privilege levels. If the admin user has configured a password for that level, you can use that password to enable higher privilege levels.For example, if your privilege level is 1, you can provide the password configured for privilege level 10 to execute all commands that require privilege level 10.This section describes the commands for:“Enabling a Higher Privilege Level” on page 89“Returning to the Default Privilege Level” on page 90IMPORTANTAn error may occur if:The privilege level that you have specified is not within the range, 1-10.You are trying to delete a password for a privilege level that is higher than your default privilege level.Command Syntaxnpu(config)# no enable password [Level <1-10>]Privilege Level10Syntax Description Parameter Description Presence Default ValuePossible Values[Level <1-10>] Indicates the privilege level for which a password is to be disabled.Optional 10 1-10Command SyntaxGlobal configuration mode
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 89  System Manual3.1.6.3.1 Enabling a Higher Privilege Level1Log in to the CLI.2Run the following command to specify the privilege level and password:npu(config)# enable [Level <1-10>]3At the password prompt, specify the password configured for the privilege level that you have specified.If you specify the correct password, you are logged in to the CLI with the privilege level that you had specified. You can now execute all commands that require the current privilege level.You can, at any time, return to your default privilege level. For details, refer Section 3.1.6.3.2.To enable a higher privilege level:NOTEYou can display your current privilege level, using the following command:npu# show privilege NOTEAn error may occur if:You have specified an incorrect password. Remember that all passwords are case-sensitive.No password is not configured for the privilege level you are trying to access.Command Syntaxnpu(config)# enable [Level <1-10>]Privilege Level10
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 90  System Manual3.1.6.3.2 Returning to the Default Privilege LevelRun the following command to disable the current privilege level, and return to your default privilege level:npu(config)# disable [Level <1-10>]After you run this command, you automatically return to your default privilege level. You can display your current privilege level, using the following command:npu# show privilege 3.1.6.4 Displaying Active UsersTo display all active users, run the following command:npu# show usersSyntax Description Parameter Description Presence Default ValuePossible Values[Level <1-10>] Indicates the privilege level you want to enable.Mandatory N/A 1-10Command ModesGlobal configuration modeCommand Syntaxnpu(config)# disable [Level <1-10>]Privilege Level1Syntax Description Parameter Description Presence Default ValuePossible Values[Level <1-10>] Indicates the privilege level you want to disable.Mandatory N/A 1-10Command ModesGlobal command mode
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 91  System Manual3.1.6.5 Displaying All UsersTo display all users, run the following command:npu# listuser3.1.6.6 Displaying the Privilege LevelTo display your current privilege level, run the following command:npu# show privilegeCommand Syntaxnpu# show usersPrivilege Level1Display FormatLine     User                 Peer Address0 con     <user name>         <value>Command SyntaxGlobal command modeCommand Syntaxnpu# listuserPrivilege Level1Display FormatUser        ModeUser 1      <value>User 2      <value>User 3      <value>Command SyntaxGlobal command mode
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 92  System Manual3.1.7 Ma na ging Se cure Shell (SSH) Pa ram et ersThe SSH parameters define the parameters used for establishing remote secure access to the device using SSH protocol rather than the plaintext-based insecure Telnet protocol.This section includes:“Configuring SSH Parameters” on page 92“Restoring the Default Values of SSH Parameters” on page 93“Displaying the SSH Parameters” on page 943.1.7.1 Configuring SSH ParametersTo configure SSH parameters, run the following command:npu(config)# ip ssh {version compatibility | cipher ([des-cbc] [3des-cbc]) |  auth ([hmac-md5] [hmac-sha1]) }Command Syntaxnpu# show privilegePrivilege Level1Display FormatCurrent privilege level is <value>Command SyntaxGlobal command modeCommand Syntaxnpu(config)# ip ssh {version compatibility | cipher ([des-cbc] [3des-cbc]) |  auth ([hmac-md5] [hmac-sha1]) }Privilege Level10
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 93  System Manual3.1.7.2 Restoring the Default Values of SSH ParametersTo restore the default value of one or more SSH parameters, run the following command:npu(config)# no ip ssh {version compatibility | cipher ([des-cbc] [3des-cbc]) |  auth ([hmac-md5] [hmac-sha1]) }.To restore the default values of all SSH parameters run the following command:npu(config)# no ip sshSyntax Description Parameter Description Presence Default ValuePossible Valuesversion compatibilityThe SSH version that can be used: The default is SSH version 2. The command npu(config)# ip ssh version compatibility enables compatibility with both SSH version 1 and SSH version 2.Optional SSH2 version compatibilitycipher ([des-cbc] [3des-cbc])The encryption algorithm used by the SSH protocol: DES-CCBC or 3DES-CBC.Optional des-cbc des-cbc3des-cbcauth ([hmac-md5] [hmac-sha1])The authentication mechanism used by the SSH protocol: HMAC-MD5 or HMAC-SHA1.OPtional hmac-sha1hmac-md5hmac-sha1Command ModesGlobal configuration modeCommand Syntaxnpu(config)# no ip ssh {version compatibility | cipher ([des-cbc] [3des-cbc]) |  auth ([hmac-md5] [hmac-sha1]) }Privilege Level10Command ModesGlobal configuration mode
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 94  System Manual3.1.7.3 Displaying the SSH ParametersTo display the current configuration of the SSH parameters, run the following command:npu# show ip ssh 3.1.8 Ma na ging the SessionThis section includes:“Locking the Session” on page 94“Managing the Session Timeout” on page 953.1.8.1 Locking the SessionTo lock the session, run the following command:npu# lockThis will prevent unauthorized persons from using the CLI without terminationg the session. The following message will be displayed:CLI console lockedEnter Password to unlock the console:Command Syntaxnpu# show ip sshPrivilege Level1Display FormatVersion          : <value>Cipher Algorithm : <value>Authentication   : <value>Command ModesGlobal command mode
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 95  System ManualTo resume the session, you must enter the password used for initiating it.3.1.8.2 Managing the Session TimeoutThe session timeout parameter defines the maximum allowed inactivity time after which the session will be terminated automatically. The default timeout is 1800 seconds. You can define a different value for the current Telnet/SSH session. You can also change the timeout value for the MON port sessions, that will apply also to future sessions via the MON port.This section includes:“Enabling the Line Configuration Mode” on page 95“Configuring the Session Timeout” on page 96“Restoring the Default Value of the Session Timeout” on page 97“Displaying a Session Timeout” on page 973.1.8.2.1 Enabling the Line Configuration ModeTo enable the line configuration mode, run the following command:npu(config)# line {console | vty}After enabling the line configuration mode you can execute any of the following tasks:Command Syntaxnpu# lockPrivilege Level10Command ModesGlobal command modeIMPORTANTAn error will occur if you select console when using Telnet/SSH or vice versa. In this case the following error message will be displayed:Cannot configure for other terminals
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 96  System Manual“Configuring the Session Timeout” on page 96“Restoring the Default Value of the Session Timeout” on page 973.1.8.2.2 Configuring the Session TimeoutTo configure the session timeout, run the following command:npu(config-line)# exec-timeout <integer (1-18000)>Command Syntaxnpu(config)# line {console | vty}Privilege Level10Syntax Description Parameter Description Presence Default ValuePossible Valuesconsole | vty The terminal running the session to be managed:Select console if you are connected via the MON port.Select vty if you are connected via Telnet/SSH.Mandatory N/A consolevtyCommand ModesGlobal configuration modeIMPORTANTFor Telnet/SSH sessions, the modified timeout is applicable only for the current session. Whenever you start a new session the default timeout (1800 seconds) will apply. Command Syntaxnpu(config-line)# exec-timeout <integer (1-18000)>Privilege Level10
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 97  System Manual3.1.8.2.3 Restoring the Default Value of the Session TimeoutTo restore the default value of 1800 seconds for the current session timeout, run the following command:npu(config-line)# no exec-timeout3.1.8.2.4 Displaying a Session TimeoutTo display the current configuration of a session timeout, run the following command:npu# show line {console | vty <line>} Syntax Description Parameter Description Presence Default ValuePossible Values<integer (1-18000)>The session timeout, in seconds.Mandatory N/A 1-18000 (seconds)Command ModesLine configuration modeCommand Syntaxnpu(config-line)# no exec-timeoutPrivilege Level10Command ModesLine configuration modeCommand Syntaxnpu# show line {console | vty <line>}Privilege Level1
Chapter 3 - Operation and Administration of the Macro BTS Using the Command Line Interface4Motion 98  System ManualSyntax Description Parameter Description Presence Default ValuePossible Valuesconsole | vty <line>The session for which the timeout should be displayed:console: a session via the MON port (even if there is currently no active session via the MON port).vty #: An active Telnet/SSH session number #. To view currently active sessions refer to Section 3.1.6.4.Mandatory N/A consolevty #, where # is the number of a currently active Telnet/SSH session.Display FormatCurrent Session Timeout (in secs) = <value>Command ModesGlobal command mode
Chapter 3 - Operation and Administration of the Macro BTS Managing Software Upgrade4Motion 99  System Manual3.2 Mana ging Softw are  UpgradeThis section includes:“Before You Start” on page 99“Upgrading the NPU” on page 99“Upgrading the AU” on page 1063.2.1 Before You St artTo load new NPU/AU software files to the unit's flash memory, you are required to execute a simple loading procedure using a TFTP application. Before performing the upgrade procedure, ensure that you have the most recent instructions, and that the correct software files are available on your computer. The NPU flash stores two NPU software files (Operational and Shadow) and three AU software files. When you download a new NPU software file to the NPU flash, the shadow file is overwritten with the newly downloaded file. When loading a new AU software file, the oldest file among the AU software files that are not mapped to any AU slot is overwritten. If all AU software files in the NPU flash are mapped to AU slots - a new AU SW file cannot be loaded.3.2.2 Upgra ding t he  NPUTo upgrade the NPU, first configure the TFTP server that you want to use for the software version download, and then download the image to the NPU flash. You can then reboot the NPU with the downloaded image. After you have tested and verified that the NPU is functioning properly with the shadow image, you can make the shadow image as the operational image.NOTETo view the current NPU software files, refer to “Displaying the Operational, Shadow, and Running Versions” on page 103.To view the current AU software files, refer to “Displaying Images Residing in the Flash” on page 118. To view which files are mapped to AU slot(s), refer to “Displaying the AU-to-Image Mapping” on page 115.
Chapter 3 - Operation and Administration of the Macro BTS Managing Software Upgrade4Motion 100  System Manual3.2.2.1 Executing the Upgrade Procedure“Step 1: Configuring the TFTP Server”“Step 2: Triggering Software Download”“Step 3: Resetting and Booting the NPU Using the Shadow Image”“Step 4: Making the Shadow Version Operational”3.2.2.1.1 Step 1: Configuring the TFTP ServerTo initiate the NPU software upgrade procedure, start with configuring the TFTP server to be used for the software version download. To configure the TFTP server, run the following command:npu(config)# software version server <server ip>NOTEThe operational image is the default image used for rebooting the NPU after system reset. The shadow image is the downloaded image that you can use to boot up the NPU. However, the next time the system is reset, it is the operational image that is used to boot up the NPU.To execute the upgrade procedure:IMPORTANTAn error may occur if you execute this command when another software download is already in progress.Command Syntaxnpu(config)# software version server <server ip>Syntax Description Parameter Description Presence Default ValuePossible Values<server ip> Denotes the IP address of the TFTP server to be used for the software version download.Mandatory N/A Valid IP address

Navigation menu