GuangZhou Walkera Technology DEVO12E 2.4GHz Transmitter User Manual DEVO 12E manual 1

GuangZhou Walkera Technology Co., Ltd 2.4GHz Transmitter DEVO 12E manual 1

Users Manual part 3 of 11

Download: GuangZhou Walkera Technology DEVO12E 2.4GHz Transmitter User Manual DEVO 12E manual 1
Mirror Download [FCC.gov]GuangZhou Walkera Technology DEVO12E 2.4GHz Transmitter User Manual DEVO 12E manual 1
Document ID2246008
Application IDvhhzY35Of3si6HJEbqniHA==
Document DescriptionUsers Manual part 3 of 11
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize267.44kB (3343007 bits)
Date Submitted2014-04-18 00:00:00
Date Available2014-04-18 00:00:00
Creation Date2014-04-15 17:30:33
Producing SoftwareAcrobat Distiller 10.1.8 (Windows)
Document Lastmod2014-04-15 17:30:33
Document TitleDEVO-12E manual 1.pdf
Document CreatorPScript5.dll Version 5.2.2
Document Author: Frank

cleUethion
Welcome to use the DEVO 12E transmitter
DEVD 1 2E
Press ENT to transmit, “Transmitting ...... " appears in the interface.
0r press EXT to exit.Press EXT to exit after another DEVO 12E
received the data.
Model Transmit
J‘ or um“: 1
No. 1
Transmitting- - - -
(2) Model receiving
Press ENT to enter Main Menu and press UP or DN to select Model Menu. Press ENT to get Model Menu
and press UP or DN to select Model Receiving, continue to press ENT to enter Model Receive setting interface
An enquiry information “Are you sure?" will be shown as below Illustration.
Press ENT to receive'
llll Model Receive "Connecting ..." and
“Receiving . " will be shown
_ in series in the interface. The
C°""ec""9 ' ' ' ' information of “Received” with
the model name will be shown
after receiving is finished. Or
press EXT to exit.
Model Receive
Model Receive
Are you sure?
Press UP or DN to choose Model Receive Ellll Model Receive
the save position. an enquiry V1 Model 1 I
information “Are you sure?"
is shown after press ENT. 2 "¢ Model 2 Model1
:gassoEed'il" to save or press 3 »—§ Model 3 Are you sure?
' 4 ’—§ Model 4
2.5 Model reset
All the model data can be restored to factory settings via Model Reset.
Press the ENT to enter Main Menu and press UP or DN to select Model Reset [W
Model Menu. Press ENT to get Model Menu and press UP or DN to
select Model Reset, press ENT to enter Model Reset setting interface.
lt is possible to store up to 30 models data in the model list of DEVO ‘M “é Model 1
12E equipment. There are two methods to reset the model data: batch 2 ’-§ Model 2
reset and single reset. 3 ,_§ Model 3
Batch reset: press UP or DN to select All Models, an enquiry information"are you sure?" will he appears in
the interface. Press ENT to reset all models, or press EXT to exit.
Model Reset ul|l| Model Reset
llll Single reset: Press UP or DN
I to choose the model you want
MM... All
No. 1
Model 1
Are you sure?
to restore, “Are you sure?" will
appear after press ENT. Press
ENT to reset or press EXT to
exit.
Model All
Are you sure?
2.6 Type Select
This device offersthree model types menu. They are Helicopter, Airplane and Glider respectively.
Press ENT to enter Main Menu and press UP or DN to select Model Type Select
~/ Helicopter
Menu. Press ENT to enter and press UP or DN to select Type Select
and press ENT to enter setting interface.
Press “ENT" button to get Helicopter, Airplane and Glider selections Airplane. . 4
and press UP or DN to select and press ENT to confirm, then press Girl
| el'
EXT to exit.
DEvo 12E717
deUethion
DEVD 12E
Welcome to use the DEVO 12E transmitter
2.7 Trim System
Trim System is able to finely tune the following six items, respectively: Elevator, Aileron, Rudder, Throttle,
Left Trim and Right Trim. The trim range is divided into 20 grades (factory default is set at 4). It is convenient
to subtly modify the pitch by adjusting the trim range.
Trim System :jiii
Press ENT to enter Main Menu and press UP or DN to select Model Elevator I
Menu. Press ENT to enter and press UP or DN to select Trim System.
press ENT to enter setting interface. m
Press UP or DN to select the trim which will set, press R to increase Aileron
the trim value and press L to decrease. 4/20
Trim System
For elevator, aileron, and rudder, there are two more options: Normal
Elevator and Limited, press R or L you can change the setup. "Normal" means
the trim is always working although the corresponding stick stays
anywhere. “Limited” means the trim is out of working when the
corresponding stick is at maximum position.
m Press EXT to exit after finished.
Aileron
2.8 Stick Position Switch
According to the following setting, the SWitch can be used as a switch. The turn-on or turn-off position at which
stick stays can also be set‘table.
Method for setting:
Press the ENT to enter Main Menu and press UP or DN to select Model S1i0k Position SW---
SWitch
Menu. Press ENT to get Model Menu and press UP or DN to select
Stick Position Switch, press ENT to enter Stick Position Switch setting
interface.
There are four options under the Stick postion switch: SPSO, SPSt,
SPSZ.SPS3. Press R or L to choose the switch you want to define.
Press UP or DN to inhibit channel in naVigation mark, and press R to expand the menu.The channel includes
four items: Elevator. Aileron. Throttle and Rudder. The factory default is Inhibit. Take Elevator for example.
Stick Position SW...
”” Slim Position SW'" Press R or L to choose the
Switch I Position Elevator as stick, then Press
SPSO SW UP or DN to move nagivation
Ch I " mark to value of position. It's
anne possible to adjust the stick
m Up position via pressing R or L.
Press UP or DN to navigate the OPEN setting. press R or L to change the direction of the channel stick.
Press UP or DN to navigate
Stick Position SW... ul||| Stick Position SW... ull|l the STATUS which can check
Position Status “ the sketch map of the stick
001., On OPEN/CLOSE direction.
On I K \ Check if it was set correctly.
K Jon I Afterfinished the setting, press
“ EXT to exit.
2.9 Device select
This setting can help you configure various functional SWitches, or adjust levers. It includes Flight Main Switch,
Flight Extra Switch, Stunt Trim, Hold Switch, Hovering Pitch. Hovering throttle.
DEVD 12E7’IB
oieUeniion
Welcome to use the DEVO 12E transmitter
DEVO ‘i EE
Press ENT to enter Main Menu, press UP or DN to move navigation D
evice Select
mark to select Model menu. Press ENT to enter Model menu function. —EHH
Press UP or DN to Device select Option. Press ENT to DeVice select Flight Main Switch I
Option interface.
Flight Extra Switch
Inhibit
(1) Flight Main Switch:
Press UP or DN to move navigation mark to Flight Main Switch and
press R or L to select the desired switch. The factory default setting
is FMOD SWitch.
(2) Flight Extra Switch:
Press UP or DN to move navigation mark to Flight Extra Switch and press R or L to select the desired sWitch.
The factory default setting is Inhibit.
(3) Stunt Trimt:
There are two modes: Common and Flight Mode. In Common Mode all the trim values. which various sticks
are corresponding to, put equall effect on all the flight modesln Flight Mode. the trim value, each of which
stick is corresponding to, puts independent effect on the corresponding stick. The factory default setting is
Common.
Press UP or DN to choose the Stunt trim, press R or L to select “Common"or "Flight Mode", the factory default
setting is "Common".
(4) Hold Switch: Refer to “(1) Flight Main switch"
(5) Hovering pitch: Refer to “(1) Flight Main switch"
(6) Hovering throttle: Refer to “(1) Flight Main switch"
After finishing the setting, press EXT to exit.
2.10 Device Output
Device output can set up the output switches respectively. It can also activate. inhibit or use otherfunctions.There
are eight items in total: FMOD SWitch, MIX switch,ELEV DIR SWitch, AILE D/R switch, RUDD D/R switch,GEAR
switch, SPSO, SPS1, SPSZ, SPS3, left trim, right trim, AUX4 KB, AUX5 KB, AUX6 KB, AUX7 KB.
Setting: Devtce Output u i I II
Press ENT to enter main menu, press UP or DN to move navigation G
mark to Model Menu. Press ENT to enter Model Menu. Press UP or ear
DN to select Output DeVice and press ENT to enter Output Device m
interface. F nct'on
u i
There are 7 settings Gear, AUX2, AUXS, AUX4, AUX5, AUX6, AUX7. Active
(1) Gear
Press UP or ON in output interface can change the gear switch. It includes FMOD, MIX ,ELEV D/R, AILE
D/R,RUDD D/R, GEAR, SPSO, SPS1, SPSZ, SPS3, Left trim, Right trim, AUX4 KB, AUX5 KB, AUX6 KB,
AUX7 KB. Press R or L to select the setting SWitch, The default setting is GEAR SW.
DeVice Output : i i ii
Gear Press UP or UN to select Function Setting after you select the switch,
Press R or L can enter the interface of Gear Inhibit. Active, Gyro,
GEAR SW Governor and Pitch . The default setting is Active. You can continue
FunCtion to set other items after finishing.
DeVice Output
(2) AUX 2
Press UP or DN to enter the AUXZ interfacePress R or L can change AUXZ
the AUX2 switch. it includes FMOD, MIX, ELEV D/R, AILE D/R, RUDD m I
D/R, GEAR, spso, SPS1, SPSZ, SPS3, Left mm, Right trim, AUX4 Fume"
KB, AUX5 KB, AUX6 KB, AUX7 KBThe default setting is FMOD SWitch.
Gyro
DEVD 1EE7’IB
oleUention
DEVD 1 2E Welcome to use the DEVO 12E transmitter
Press UP or DN to select the Function Setting. press R or L to choose
the switch, it inculdes Inhibit, Active, Gyro, Governor and Pitch the
Device Output ill I
default setting is Gyro. You can continue to set others items after AUXZ
finishing. FMOD SW I
Function
DeVIce Output u i | ||
AUX3 (3) Auxs —
RUDD DIR I Press UP or DN to enter AUX3 interface. Press R or L can change
. the AUX3 switch. It includes RUDD DIR, GEAR, SPSO,SPS1, SPSZ,
Fund'on SPSS, Left trim, Right trim,AUX4 KB, AUX5 KB, AUXS KB,AUX7 KB.
Gyro The default setting is RUDD D/R switch.
Device Output
Press UP or DN to move navigation mark to Funtion Setting. Press
R or L to desired item.The optional items are Inhibit, Active, Gyro, AUX3
Governor and Pitch. The factory default is Gyro. Continue to set up RUDD DIR I
other items after setting finished. Function
(5) AUX4, AUXS, AUXS, AUX7 settings please refers to AUXS settings. AUX4 default setting is AUX4 KB;
AUXS default setting is AUXS KB: AUXS default setting is AUXS KB: AU><7 default setting is AUX7 KB.
After finishing the setting, press EXT to exit.
2.11 Swash Type
The swash type is grouped into six options: 1 Servo Normal, 2 Servos 180°, 3 Servos 120°,3 Servos 140“, 3
Servos 90° and 4 Servos 90°.
Swash Type a i i ii
Press ENT to enter Main Menu, press UP or DN to move navigation
mark to Model Menu. Press ENT to enter Model Menu. Press UP or
UN to select Swash Type and press ENT to enter Swash Type interface. 2 Servos 130°
Press UP or DN to choose the required "Swash type", press ENT to 3 Servos 120°
confirm, the corresponding items will have the"«/" mark in front of the 3 Servos 140“
items. Press EXT to exit after finishing.
2.12 Power Amplifier
The transmission output power of DEVO 12E is adjustable. It is divided into six grades from small to big.
The lower the transmission output power transmits, the shorter the radio range is, and the longer the stand-
by time will be, the higher the transmission output power, the farer the radio range, and the shorter the stand-
by time. Choose the appropriate transmission output power according to the actual situation.
Press ENT to enter Main Menu, press UP or DN to move navigation mark to Model Menu. Press ENT to
enter Model Menu. Press UP or DN to select PowerAmplifier and press ENT to enter PowerAmplifier interface.
PowerAmplifier ul||| Press UP or DN to choose the desired output power value. Press
V +20 dBm ENT to confirm then the corresponding items will have "¢"mark in
front of the items.
+15 dBm
+10dBm T I I I I Grades Grade 5 Grade4 Grade3 Grade2 Grade1
*5 dBm zodem 15dBm 10dBm 5dBm OdBm -5dBm
After the setting, press EXT to exit
2.13 Fixed ID
This setting will bind DEVO 12E with its receiver in a unique corresponding relationship. It Will greatly speed
up the time of automatic binding when DEVO 12E power on.
DEVD 1 EE 720
oleUention
DEVD 1 EE
Welcome to use the DEVO 12E transmitter
(1) Setting for fixed ID
The setting for fixed ID should be under the status that automatic ID binding is successfully finished. Below
is the setting method.
Press ENT to enter Main Menu, press UP or DN to move navigation mark to Model Menu. Press ENT to
enter Model Menu. Press UP or DN to select Fixed ID and press ENT to enter Fixed ID setting interface.
Fixed ID IIII Fixed ID
I I I I If you want to activate the fixed
ID setting, press R or L to
change the status from off to
Status “ Status “ on. A series of random digits
will be shown below after
ID Code 326186 changing to on.
Fixed ID DIIII
Press UP or DN to choose the ID code setting, press R or L to coose Status On
the words or number. press UP or DN moves to the next code setting
. there are 6 words can be set to ID code.
ID Code E26186
Press ENT after the new ID has been set An inquiry interface of “Are you sure?" pop up. “ID Code Matching
.. Will be shown after
press ENT. After matching,
the interface will be returned
to Model Menu. Fixed ID
Fixed ID EIIII Fixed ID
ID Match - - - -
Are you sure?
(2) Fixed ID cancellation
Insert the assorted BIND PLUG into the output terminal of BATT before the receiver power on. and then plug
5V DC power into other output terminal. The red light of receiver Will flash slowly. This means the fixed ID
code has been cancelled. Pull out bind plugDEVO 12E also need to make relative cancellation and revision
after the fixed ID in receiver is cleared out.
In the main interface press the ENT to enter Model Menu and then
press UP or DN to move the navigational mark to select Model Menu. A
Press ENT to enter Model Menu. Press UP or DN to select Fixed ID H
code and push ENT to enter the Fixed ID code interfacePress UP
M 7
or DN to select STATUS option. Press R or L to change the status
to off. Then press EXT to exit.
2.14 Sensor setting
Setting method: press ENT enter to the Main Menu. Press UP or DN to select the Model Menu. Press ENT
enter to Model Menu. Press UP or DN to select sensor press ENT enter to the sensor setting interface. See
the Illustration.
Sensor Setting II I I
sens” Slams Press R or L to select Activate or Inhibit (the default setting is Inhibit),
m such as press Activate will includes No Signal Warning,Voltage
sensor,Temperature sensor,GPS receiver setting etc.
DEVD ’I BE iE’I
(JeUethion
DEVO 12E
Welcome to use the DEVO 12E transmitter
(1) N0 Signal Warning Sensor Setting
Press UP or DN to make the navigation mark to choose “No Signal
Warning". Press R or L to choose " Inhibit" or “Active"(default setting
is" inhibit“). If you choose “Active", the Radio will alarm when telemetry
signal lost. Picture as right:
Sensor Status
Active
No Signal Warning
There are 3 different types of voltage can be measured.lt includes Internal 5V,External V1 and V2 which can
be monitored two different external voltage(i.e. battery) respectively.0nce the measured voltage is lower than
the setting value, the Radio will alarm.
(2) Voltage setting
(2.1) Receiver 5V(|nternal) PFV(Power Feeding Voltage) Alarmed value can be setted as 3 6-
Voltage setting: press R or L to activate the 5V, the alarm interface will appear in the interface , please refer
to the lllustration.
Voltage H l l Voltage
H" Press UP or DN to select the
internal; 5v I lnternal: 5v I Alarm Voltage setting,press
m Active R or L to set the value. The
Alarm Voltage range is 3.6-6V. you can
continue to set other items
after you finished.
(2.2) External V1
Press UP or DN enter to External V1 setting interface. Press R or L to activate the V1, the details refers to
the lllustration.
Voltage m. Voltage
Press UP or DN to select the
External: V1 External: V1 Alarm Voltage setting. Press
m Active R or L to set the value. The
Alarm Voltage setting range is 0.2~99.9V.
Alarm Voltage you can continue to set other
0.2 V items after you finished.
(2.3) External: V2 setting can refer to External V1 setting.
Press EXT back to sensor setting interface after you finished.
(3) Temperature sensor
The temperature sensor can measure up to 4 different lemperature(i.e.motors).You can choose Celsius or
Fahrenheit.The alarmed value can be setted to 4 different temperature.0nce the measured value is higher
than the setting value,the radio will alarm.The Alarm Temperature value can be setted as -20-220‘C or -
4.0~428.0” F.
Temperature in I
Temperature Setting: W
Unit I
In the “Sensor Setting“interface, press UP or DN to make the navigation ‘
mark to choose “Temperature Sensor". and press ENT to enter T1 Inh'b‘t
“Temperature Sensor"setting interface. See the illustration.
T2 Inhibit
(3.1) Unit
Press UP or DN to make the navigation mark to choose “Unit"setling item,and press R or L to choose Unit,
two kinds of Unit:CeIsius and Fahrenheit.
(3.2) Alarm Temperature settings
Press UP or DN select the T1 ,Press R or L to Active the setting. Inhibit Will change to Active and Alarm
temperature Will be shown. If you choose Inhibit, the Alarm temperature value won't be shown.
DEVD 1 BE 7 22
oleUention
Welcome to use the DEVO 12E transmitter
DEVC] 1 2E
Press UP or DN to select “Alarm"setting, press R or l_1o set the alarm
T t . . .
w temperature value. Press UP or DN to set other Items after finishing
Unit Celsms the setting.
T1 Active
Alarm _ (3 3) T2, T3, T4 setting
T2 Inhibit Refer to the step of “(3.2)T1".
(4) GPS setting GPS Setting a l | II
There are 4 items including Altitude Type,Speed Unit, Date Type and Altitude TYli’e
Time Zone in the GPS receiver setting interface. Absolute
Press UP or DN to select the Sensor setting interface to enter the Speed Unit
GPS setting interface Knots
(4.1) Altitude Type
Press UP or DN to select the Altitude type on the GPS setting interface and it's Absolute and Relative.
(42) Speed Unit GPS Setting all“ GPS Setting Di...
Press UP or UN to select the Altitude Type I Altitude Type I
Speed Unit on the GPS setting _
interface and it includes knots Relative Relative
and km/h and relative. Select Speed Unit SPEEG Unit
(4.3) Date Type
Press UP or DN to select the Date Type on the GPS setting interface and it includes DD-MM-YY,MM-DD-
YY and YYVMMVDD. Select the desired item.
GPS Setting :llll GPS Setting DH“ (44) Time Zone
Date Type Date Type
Press UP or DN to select the
DD-MM- DD’MM’YY Time Zone , pressRorLto
Time Zone Time Zone set the desired Time Zone.
UTC+08:00 UTC+08:DD
3.0 Functi Menu
Function Menu can help you custom adjustments for the selected models. The rnenu include items such as
Reverse Switch, Travel Adjust, Sub Trim, Dual Rate and Exponential. Throttle Hold, Throttle Curve, Mix to
Throttle.Gyro Sensor. Governor.Tail Curve. Dual Pitch Swash Mix .Pitch Curve, Program MlX, Monito ,Fail
Safe, Sensor view, Trainer and Timer.
3.1 Reverse Switch
Press ENT to enter Main Menu; Press UP or DN to move the navigation
mark to Function Menu. And press ENT to enter Function Menu, Press
UP or DN to choose Reverse Switch and Press ENT to enter into
Reverse SWitch interface.
Reverse Switch
Elevator
Aileron
Press UP or DN to move navigation mark to ELE(taKe Elevator for
example). Press R or L to shift the status between nomal and reverse.
These are two status for option. And the default setting is Normal.
All Channels Reverse Switch like: Aileron, Throttle, Rudder, Gear,
Pitch, AUX2, AUX3, AUXA, AUX5, AUX6 and AUX7 can be referred
to the way of ELEV Reverse Switch. And press EXT to exit after
finishing setting.
Reverse Switch
Elevator
Reverse
Aileron
Normal
DEVD ‘l EE 723
oleUention
DEVD 1 EE Welcome to use the DEVO 12E transmitter
3.2 Travel Adjust
Press ENT to enter into Main Menu. Press UP or DN to move naVigation mark to select item Function Menu.
Press ENT to enter Function Menu. Press UP or DN to select Travel Ajust, Press ENT to enter Travel Adjust
interface, as below illustration. It shows the Travel Adjust status of one channel:
Travel Adjust Take ELEV for example, Press UP or DN to move navigation to
— desired item Elevation of U. Press R or L to increase or decrease
Elevator the servo travel range. The adjustment range is from 0.0% to 150.0%.
The factory default is 100.0%.
Press UP or DN to move navigation mark to deSired item D of ELEV.
D100.0% Press R or L to increase or decrease the servo travel range. The
range is from 0.0% to 150.0%. The tactory default is 100.0%.
All other channel’s Travel Adjust like Aileron, Throttle, Rudder, Gear, Pitch, AUXZ, AUX3, AUX4, AUXS, AUXG
and AUX7 can be referred to ELEV travel Ajust. Press EXT to exit after setting finished.
3.3 Sub Trim
Sub Trim can move the neutral point of the servo. But we advise you to mechanically adjust the servo bell
crank it offset is far away from the neutral point of servo, because excessive usage ofthe sub trim may damage
the servo.
Setting method: SUb Trim :Iiii
_ Elevator I
Press ENT to enter Main Menu, Press UP or DN to move the navigation
mark to select item Function Menu. Press ENT to enter Function Menu, ' °
Press UP or DN to select Sub trim. and press ENT to enter Sub Trim Aileron
interface. 013%
The interface show the items and the channels which are adjustable. Press R or L to change theI neutral
point of Servos. The lactory default is 0.0%. Press UP or DN to choose desired items The range as below:
Channel name Adjustment range Channel name Adjustment range
Elevator 062.5% ~ U62.5% -62.5% ~+62 5%
Aileron R62.5% ~ L62.5% AUX3 -62.5% ~+GZ 5%
Throttle L62.5% - H62.5% AUX4 -62.5"/o ~ +62.5%
Rudder R62.5% ~ L62.5% AUX5 -62.5% ~ +62.5%
Gear -62.5% ~ +62.5% AUXG -62.5"/e ~ +62.5°/o
Pitch L62.5% ~ H62.5% AUX7 -62.5% ~ +62.5%
Press EXT to exit after adjustment finished.
3.4 Dual rate and Exponential
After this function is set up, it is possible tor D/R switches to control the dual rates of elevator, aileron and
rudder, respectively. The setting range is covered from 0% to 125%. Under the help with exponential curve
adjustment, it is possible to make both customized setting and automatic setting. The switch between Dual
rate and Exponential can be performed via pushing or pulling the Flight Mode Lever.
Setting method: Dual Rate and EX... [Hll
Press ENT to enter Main Menu Press UP or DN to move navi ' Channel V ’ . I
. gation
mark to desired item Function Menu Press ENT to enter Function m
Menu, press UP or DN to choose Dual rate and Exponential, Press Position
ENT to enter DIR and Exponential interface. Pos 0 J
DEVC} 1 2E 724
cieUeniion
Welcome to use the DEVO 12E transmitter
DEVD 4 2E
(1) Channel selection
Press UP or UN to move navigation mark of Channel, Press R or L to set up channels containing Elevator,
Aileron and Rudder. Choose the desired channel for setting.
(2) Position selection
Press UP or DN to move navigation mark to desired item Position
In the manual mode, the function of Dual rate and Exponential
will be executed by the corresponding D/R sWitch among P050
and Post . Take the item Elevator at channel as an example.
It's possible to shift between Post) and Post via pushing or
pulling the D/R sWitch
Dual Rate and EX... Ellll (3) Dual rate adjustment
Position . . .
P05 0 Press UP or DN to move the naVigation mark to desired item Dual
Rate. It’s possible to change the dural rate value of Postion via
Dual Rate pressing R or L and the corresponding value curve in the right top
100% of interface Will be changed accordingly. The factory default is 100%.
(4) Exponential Dual Rate and EX...
Press UP or UN to select Exponential item of navigation mark. It's Dual Rate
possible to change Dual Rate and Exponential value in Pos when 100%
pressing R or L to change the value. There are;100% and Line
three adjustment. At the same time. the corresponding curve Will be
changed and shown at the right graph.
Exponential
(5) Automatic setting
Under working with Flight Mode, it's possible to switch between the Dual Rate and Exponential, which are
set in above"(3) Dual Rate adjustment" and "(4) Exponential adjustment", respectively.
: Flight Mode The setttings for Normal Mode, Stunt 1, Stunt 2, Stunt 3, Stunt
.7 : 4 and Throttle Hold are available. But for Stunt 3 and Stunt
“ I i n i 4, Flight Mode Extra SWitch at DeVice Select in Mode Menu
a should be activated(Refer to "2.9 Device Select"), and Throttle
s: Hold in Function Menu should be set as Active(Refer to "3.5
e Throttle Hold" below).
‘ e ‘
(5.1) Normal Flight Mode setting:
Press UP or DN in the navigation mark of Dual rate and Exponential Dual Rate and EX"-
to select the desired item Normal Flight. Press R or i. to set the position Normal Mode
and the Switch. Only the DIR switch control is valid When Switch is
selected, under the Flight Mode, it’s possible for Pos lo SWitch the m
dual rate and exponential, which are set in above(3) and (4)Exponential Stunt 1
adjustment. The settings for Swtich, PosO, Pos’l, P052 . Pos3, Pos4 SWitch
and P055 are valid.
(5.2) The setting for Stuntt, Stunt2. Stunt3. Stunt4 and Throttle Hold can be set up according to above Normal
Flight Setting.
Press EXT to exit after finishing the setting.
3.5 Throttle Hold
If this function is set. the switch will be exectuted by hold switch. The setting value of throttle hold is ranged
from 720.0750.0% the default setting is Inhibit.
DEVO ’l EE 725
oleUenlion
DEVD 1 EE Welcome to use the DEVO 12E transmitter
Setting method:
Press ENT to enter Main Menu. Press UP or DN to move navigation mark to select Function Menu. Press
ENT to enter Function Menu. Press UP or DN to select Throttle Hold. Press ENT to enter Throttle Hold
interface. as below illustration'
Throttle Hold
Hold Status
Throttle HOId Press R or L to activate
Hold Status Throttle Hold function, and
expansion list will be shown
m as Throttle hold status. Hold
Hold Position position Throttle Stick and
_ 50% Hold SWitch.
(1) There are two items under Throttle Hold Status: Active and Inhibit. The factory default setting is Inhibit.
(2) Hold Position
In the Throttle Hold interface. press UP or DN to make the NaVigation mark to choose "Hold Position" setting
options. Press R or L to change data. the minimum value is -20.0%; the maximum value is +50.0%.
(3) Throttle Stick
Throttle Hold
on the interface "Throttle hold". choosing the Throttle Stick by button —
UP or DN. press R or L. the expansion list Will be shown as Inhibit Throttle Stmk
and Active. default setting is Inhibit. if turning Active. menu "amount m
decrease" Will be seen. you can set it by button UP or DN. data
changes will be vontrolled by R or L. the minimum is 0.0% and the C‘” P°5“‘°"
maximum is 100.0%.
(3) Throttle Switch setting
Throttle Hold :iiii
W It's invalid for setting. the factory default is RUDD DIR which Will be
shown in the status item. When the Throttle Hold switch is on. data
RUDD D/R under the Throttle Hold can not be amended until Throttle Hold sWitch
Status I to be off. and the hold status is changed.
“ Press EXT to exit after setting up finished.
3.6 Throttle Curve
Throttle curve are adjusted through seven points. which of all the flight modes can be respectively set. The
flight mode include Normal Flight. Stunt 1. Stunt 2. Stunt 3 and Stunt 4 while Flight Modes Extra SWitch in
Device Select should be activated(Refer to "2.9 Device Select").
Press ENT to enter main menu. Press UP or UN to move navigation mark to select Function Menu. Press
ENT to enter Function Menu. Press UP or DN to select Throttle Curve. Press ENT to enter Throttle Curve
interfaceThe enquiry dropdown
ls shown"A|l servos hold?" If Throttle CW9 ”H” “mm Curve :iiii
select OK. all the servos will Fugm Mode ._0_ _ 0.0 I
be locked at the current status. All Servos Hold?
if click Cancel. all the servos m
will be unlocked at the current OK Cancel Exponential
status. Ofl
nus—no
(i) Flight Mode
There are total five flight modes: Normal Flight. Stunt 1. Stunt 2. Stunt 3 and Stunt 4. The Curve of which
can be respectively set in their corresponding flight mode. The setting method is to press UP or DN to select
Flight Mode in Throttle Curve interface. The corresponding flight mode Will be shown when the Flight Mode
switch shifts via pushing or pulling the Flight Mode Switch. And the exponential can be adjusted after Flight
Mode is selected.
DEVD 1 BE 7 26

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Frank
Create Date                     : 2014:04:15 17:30:33-07:00
Modify Date                     : 2014:04:15 17:30:33-07:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2014:04:15 15:32:04+08:00
Format                          : application/pdf
Creator                         : Frank
Title                           : DEVO-12E manual 1.pdf
Producer                        : Acrobat Distiller 10.1.8 (Windows)
Document ID                     : uuid:606d2b5d-e99e-4720-850d-09cca6a684f7
Instance ID                     : uuid:b9ec3f56-2862-4af0-be64-daddfbbff56e
Page Count                      : 10
EXIF Metadata provided by EXIF.tools
FCC ID Filing: S29DEVO12E

Navigation menu