GuangZhou Walkera Technology DEVO12E 2.4GHz Transmitter User Manual DEVO 12E manual 1
GuangZhou Walkera Technology Co., Ltd 2.4GHz Transmitter DEVO 12E manual 1
Contents
- 1. Users Manual part 1 of 11
- 2. Users Manual part 2 of 11
- 3. Users Manual part 3 of 11
- 4. Users Manual part 4 of 11
- 5. Users Manual part 5 of 11
- 6. Users Manual part 6 of 11
- 7. Users Manual part 7 of 11
- 8. Users Manual part 8 of 11
- 9. Users Manual part 9 of 11
- 10. Users Manual part 10 of 11
- 11. Users Manual part 11 of 11
Users Manual part 7 of 11
oleUethion DEVC} 1 EE Welcome to use the DEVO 12E transmitter (4.1) Point set'ting Press UP or BM in Throttle Curve interface to select Points setting. Press R to expand a list including seven points "Point-L". “Point-1". “Point— Point-M“. “Point-3". Throttle Curve uiiii Throttle Curve :Iiii “Point- and "Point-H". Press Point °-.”. °S Point R or L to select the point you want to adjust. I m ‘ Status . . LliMéAFi Inh'b" (4.2) Status setting Press UP or DN to move navigation mark to Status and press R or Throttle Curve PW“ L to choose inhibit or Active. Select Inhibit if keeping the current Point- M value(lhe default setting is inhibit). Select Active for changing the Status above points' value. Note: After select point L or PointrH. the status setting won't be display. Lizrtliéii (4.3) Output setting There is a expand item “Output" after select Status Active. press UP or DN to select Output setting. press R or L to increase ordecrease. respectively. the output value. The adjustable range is from 0.0% to 100.0%. The curve graph in right will be change accordingly. Throttle Curve Output 5 A Throttle Stick Inhibit Li' iMiA'H I (5) Throttle Stick setting The sWitch between Pos 1 and P05 0 can be freely realized through throttle stick after the below amount has been set up. The below set amount is the position of throttle stick as well as the switch point. Throttle Curve llll 09., 0 LiéMthi-i I Output 50.0% Throttle Stick Throttle Stick setting: Press UP or DN to select Throttle Stick seting. Press L to decrease the amount with a lower limit of 0.0% or lnhibit. Press R to increase the amount with an upper limit of 100.0%. (6) Switch Selection When the item Throttle Stick is set in Inhibit. it is possible to switch between Pos 0 and Pos 1 by Switch. Press UP or DN to select “Switch". Press ENT to enter Switch interface. press UP or DN to choose desired item. Press ENT to confirm. the desired item whose left side will be changed into “1" from “"0. If two or more items are selected. the item And should be selected. w SWitch Ell“ whose left side should be Throttle Stick .1 —I changed into “1" from “0" Inhibit © Flight Mode0 Press EXT afler finished it. Switch © Flight Mode1 © Flight Mode 2 3.7 Differential If want to use this function. Flaperon. Delta. or 4-Aileron should be previously selected in Wing Type of Model Menu. Refer to “2.11 Wing Type". DEVC} 1 BE 757 oleUention DEVD ‘l EE Welcome to use the DEVO 12E transmitter (1)Aileron differential setting Press ENT to enter Main menu: press UP or DN to choose Function menu. Press ENT to enter Function menu; press UP or DN to choose Differential. press ENT to enter interface of Differential, illustration as below. Differential llll Mounting servos in left and right ailerons are a must if using this function. The following interface will be shown after Flaperon, Delta, or 4-Aileron selected in Wing Type. Refer to “2.11 Wing Type“. (1.1) Channel Current setting channel is Aileron. System default can 0% not be set. (1.2) Setting for Pos 0 Press UP or DN to choose Pos 0, press R or L to increase or decrease differential value, respectively. The adjustable range is i 100%. Differential Ellll Differential (1.3) Setting for Pos 1 Pos 0 Pos 0 Press UP or DN to choose 0% Post. press R-or L to-increase or decrease differential value, Pos 1 P95 1 respectively. The adjustable 0% range is :t 100%. (1.4) SWitch selection It is possible to sWitch by Setting Switch when differential is in use. Press UP or DN to choose Switch, press ENT to enter interface of Switch selection, press UP or DN to choose desired item. Press ENT to confirm. the desired item whose left side will be changed into “1" from ‘".0 If two or more items are selected, the item And should be Differential ullll SWitch :iiii should be changed into “1" . from “0". Press EXT after 0% © FlightModeO © Flight Mode 1 In. I ©FiigmMode2 finished it. SWitch (2) Rudder differential setting V—Tail should be previously set in Wing Type of Model Menu if the rudder differential function is activated. Refer to “2.11 Wing Type". And then the following interface will be shown: DifferentiaI [W (2.1) Setting for Pos 0 Channel Press UP 0r DN to choose Pos 0, press R or L to increase or decrease differential value, respectively, the value With a range of: 100%. (2.2) Setting for Pos 1 Pos 0 o Press UP or DN to choose Pos’l, press R or L to increase or decrease 0/° differential value, respectively, the value With a range of: 100%. (2.3) SWitch selection It is possible to sWitch by Setting Switch when differential is in use. Press UP or DN to choose Switch, press ENT to enter interface of Switch selection, press UP or DN to choose desired item. Press ENT to confirm, the desired item whose left side will be changed into “1" from ”'0'. If two or more items are selected. _ the item And should be D'flerem‘a' Illi SWitch :Illl should be changed into “1" _ from “".0 Press EXT after 0% © FlIghtModeO © Flight Mode 1 finished it. SWitch m © Flight Mode 2 DEVD 1 EE 7 58 oleUeniion DEVD 1 EE Welcome to use the DEVO 12E transmitter (3) Flap differential setting It should be previously set the flap dual channel function in Wing Type of Model Menu (refer to “2.11 Wing Type") in order to activate the menu of Flap Differential. (3.1) Setting for Pos 0 Press UP or DN to choose Pos 0, press R or L to increase or decrease Channel differential value. respectively. The adjustable range is i 100%. m (3.2) Setting for Pos 1 P05 0 Press UP or DN to choose P051, press R or L to increase or decrease 0% differential value. respectively. The adjustable range is i 100%. Differential : i i ii (3.3) SWitch selection It is possible to SWitch by Setting Switch when differential is in use. Press UP or DN to choose Switch, press ENT to enter interface of Switch selection, press UP or DN to choose desired item. Press ENT to confirm, the desired item whose left side will be changed into “1" from ”"0. If two or more items are selected. the item And should be Difleren‘W Iiii SWitch :Iiii should be changed into “1" ‘ from “"0. Press EXT after 0% © FlIghtModeo finished it. SWitch © Flight Mode 1 Iza- I © This function can adjust the parameters of the two servos which are used in the dual channels. It should be previously activated one of these wing types of Flaperon, Delta. 4rAileron, and VaTail in Wing Type at Model Menu. Refer to “2.11 Wing Type". 3.8 Balance Balance u i | i | Setting method: Channel Press ENT to enter Main Menu. press UP or DN to choose Function. Press ENT to enter Function menu, press UP or DN to choose Balance. Press ENT to enter interlace 0' Balance setting, picture as right: (1) Channel: current setting channel is Aileron. System default can not be set. Balance Ht) (2) Point parameter adjustment Point < Right i Point< Right Setting: Press UP or DN to choose “Point< Right“. It need to adjust the value. press L (0% means no adjusting). A minus value means the amending direction is downward: press R to adjust value(0% means no adjusting) A plus value means the amending direction is upward. The adjustable range is :100%. Point-Right Setting: Press UP or DN to choose “Point-Right". Press R or L to Inhibit or Active. If need to adjust please Active it There will be expanded value adjustment item. Press UP or DN to choose “0%" It need to adjust the value, press L (0% means no adjusting). A minus value means the amending direction is downward; press R to adjust value (0% means no adjusting). A plus Balance aliii Balance DH” value means the amending Point- Right Point _ Right direction is upward. The I I Active Press UP or DN. there will be setting for Point-1. Point-2, Point-3. Point-Left. Point>Left, refer to the setting method as above. Press EXT after finished it. adjustable range is 100%. m DEVD 1 EE 7 EB cJeUention DEVD 1 2E Welcome to use the DEVO 12E transmitter 3.9 Gyro Sensor This function offers the gain adjustment for gyro sensor, which can be manually set through DIR SWitches or Flight mode switch. and also is possible to be automatically switched among various gains through flight mode switch (The flight rnode should be activated. Refer to “2.9 Device Select"). Setting method: (3er Sensor Press ENT to enter Main menu; Press UP or DN to choose Function menu. Press ENT to enter Function menu; Press UP or DN to choose Gyro Sensor setting, press ENT to enter the setting interface of Gyro m Sensor setting. Mode Channel (1) Manual Setting AUX2 (1.1) Manual Setting: Under Gyro setting interface, press UP or DN to choose Mode, press R or L to select Manual setting or Automatic Setting (Automatic setting can be activated if Flight mode is act, refer to “2.9 Device selection"). Choose “Manual Setting" (1.2) Channel: The default setting is AUX 2. It is possible to alter into other channels in the interface of Device Output (Refer to “2.10 DeVice Output"). Gyro Sensor (1.3) SWitch selection: Under Gyro setting interface, press UP or UN to choose Switch, press SWilCh R or L to expand into six articles: FMOD SW, MIX SW, ELEV DIR, ELEV DIR AILE DIR, and RUDD DIR, GEAR SW. Choose the desired swnch for Manual control. Statu 5 Pos 0 (1.4) Sensitivity Setting If choose 3 switches.there are “position 0","position 1" and “position 2". then set the sensitivity individually: If choose 2 switches,there are “position 0" and "position 1" , then set the sensitivity individually. Gyro Sensor ii i l Status (1.4.1) Status: m I Turn the setting gyro control switch,the status items will display the p03 0 current switch status position. 50.0% (1.4.2) Pos 0: Press UP or DN to move the navigational mark to Pos 0 and press R or L to increase or decrease, respectively, the value.lf the gyro used has two modes of NOR and AVCS, NOR will be activated when the value is less than 50.0%. In NOR mode. the smaller the value is. the bigger the gyro sensor sensitivity will be. The factory setting is 50.0%. (1.4.3) “Pos 1"," Pos 2" are the same setting way as above “Pos 0". (2) Automatic setting Gyro Sensor (2.1 ) Automatic Setting: Mode Under Gyro setting interface, press UP or DN to choose Mode, press m I R or L to select Manual setting or Automatic Setting. Choose “Automatic Setting" Channel (2.2) Channel: The default setting is AUX 2. It is possible to alter into other channels in the interface of Device Output (Refer to “2.10 DeVice Output"). AUX2 DEVD 1 EE 7 5D (JeUention Welcome to use the DEVO 12E transmitter DEVC] 1 2E (2.3) SWitch: The switch function isn‘t available under Automatic setting. (2.4) Status: Turn the Flight Mode Switch, the status display present flight mode position.There are “Flight Mode 0",“Flight Mode 1",“Flight Mode 2", "Flight Mode 'Flight Mode 4" sets. For Flight Mode 3 and Flight Mode 4, Flight Mode Extra Switch should be activated in Device Select (Refer to "2.9 Device Select“). (2.5) Flight Mode 0: Press UP or DN to select Flight Mode 0, press R or i. can increase or decrease the value individually lfthe gyro used has two modes of Flight Mode 0 NOR and AVCS, NOR Will be activated when the value is less than 50.0%. In NOR mode, the smaller the value is, the bigger the gyro sensor sensitivity Will be. The factory setting is 50.0%. (2.6) Flight mode 1, Flight mode 2, Flight mode 3, Flight mode 4 settings refer to “Flight Mode 0". (3er Sensor Flight Mode 1 50.0% After finishing the set, press EXT to exit. 3.10 Governor Before setup this function, "Governof' should be set and activated in “Device output" interface. (Refer to 2.10 Device Output) The control proportion of governor can be separately set in various flight modes. For the absolute revolution amount, please set in external governor. The amount shown in DEVO 12E governor is just a percentage for reference. The actual revolution should be read in the external governor. Press “ENT" to enter the “Main menu“ interface; Press “UP or UN" to Governor make the navigation mark to select "Function menu“. Press "ENT" to “Funcation menu", Press UPor DN to choose “Governor" then press Status ENT to enter the Governor setting interface. which display the options of Status and channels;Press UP or DN, there are options of “Flight Channel Mode 0“, "Flight Mode 1", "Flight Mode 2", “Flight Mode 3" , ”Flight AUX3 Mode 4" and so on. (1) Status Turn the Flight Mode SWitch”, the status display present flight mode position.There are “Flight Mode O“,“Flight Mode 1",“Flight Mode 2", "Flight Mode 3", "Flight Mode 4" sets. For Flight Mode 3 and Flight Mode 4, Flight Mode Extra Switch should be activated in Device Select (Refer to "2.9 Device Select"). (2) Channel: The setted channels will display in “2.10 DeVIce output" (refer to 2.10 DeVice Output) (3) Flight Mode 0 Governor Press “UP or DN" to make the naVIgation choose the “Flight Mode Flight Mode 0 0"set, press R or L to increase or decrease the value.The factory o default value is 0%, adjustable range 1125%. Flight Mode 1 (4) Flight mode 1, Flight mode 2, Flight mode 3, Flight mode 4 settings 0% refer to “Flight Mode 0". Press EXT to exit after finished. 3.11 Aileron to Rudder Mix This function is possible to execute the mix of aileron to rudder, which is controlled by switch. Aileron to Rudder... :iiii Setting method: Pos 0 Lefl . Press ENT enter to Main menu, press UP or DN to select Function menu. Press ENT enter to Function menu. Press UP or DN select P05 0 Right Aile-ron-toRudder Mix, press ENT to enter Aileron to Rudder Mix 0% setting Interface. DEVD ’l BE 761 cleUention DEVO 1 EE Welcome to use the DEVO 12E transmitter (1) Pos 0 Setting leftward setting Press UP or DN to move the Navigation mark to select "Pos 0 Left" setting options Press R or L to change mix value of Rudder when moving the aileron stick leftward. it is possible to change the mix direction via changing the plus or minus sign before the value. The adiustable mix is :125% (2) Pos 0 Setting rightward setting Press UP or DN to move the Navigation mark to select "Pos 0 Right" setting options Press R or L to change mix value of Rudder when moving the aileron stick rightward. It is possible to change the mix direction via changing the plus or minus sign before the value. The adiustable mix is :125% (3) Pos 1 setting, the setting is same as above. (4) Throttle stick setting The switch between Pos 0 and Fos 1 can be realized by setting the position of throttle stick. Press UP or DN of Throttle Stick to set the position amount of throttle stick. The default setting is Inhibit. The adjustable range is 0.071000%. (5) Switch setting The sWitch will display the current switch position. Press UP or UN to choose SWitch, press ENT to enter interface of Switch selection, press UP or DN to choose desired item. Press ENT to confirm, the desired item $2222.}iiioi'fi‘irflf’i w Swrcn two or more items are Throttle Stick selected, the item And should . . . be selected, whose left side Inh'b" © thm Mode 0 should be changed into “1" SW‘tCh © Flight Mode 1 from “0". Press EXT after m @ Flight Mode 2 finished it. 3.12 Elevator to flap mix This function is used to execute the mix of elevator to flap. Press ENT enter to main menu,press UP or DN to select function menu. Press ENT to enter to function menu. Press UP or DN to select Elevator to flap mix.press ENT to enter to Elevator to flap mix setting interface. Elevator to Flap... Ellll (1) Pos 0 UP setting Pos 0 Up 0"/ Press UP or DN to move the navigational mark to select item Pos 0 UP, press R or L upward mix value of Elevator to flap mix will be p03 0 Down changed. The mix direction will be revised by changing the sign of 0% plus or minus before the value. The adiustable range is 1125%. (2) Pos 0 Down setting Press UP or DN to move the navigational mark to select item Pos 0 Down, press R or L downward mix value of Elevator to flap mix Will be changed. The mix direction will be revised by changing the sign of plus or minus before the value. The adiustable range is 1125%. (3) Pos 1 setting. the setting is same as above. (4) Throttle stick setting The switch between Pos 0 and F05 1 can be realized by setting the position of throttle stick. Press UP or DN of Throttle Stick to set the position amount of throttle stick. The default setting is Inhibit. The adjustable range is 0.071000%. DEVD 1 2E 7 62 oieUeniion DEVU 1 EE Welcome to use the DEVO 12E transmitter (5) Switch setting The SWitch will display the current switch position. Press UP or DN to choose SWitch. press ENT to enter interface of Switch selection. press UP or DN to choose desired item. Press ENT to confirm. the desired item whose left side will be . changed into “1.. from 0 If Elevatorto Flap... uliii Swnch :liii two or more items are Throttle Stick selected. the item And should . . . be selected, whose left side Inh'b" © thm Mode 0 should be changed into “1" SW“°h @ Flight Mode 1 "0'“ “0"- Press EXT after W © FlightMode2 finished it. 3.13 Rudder to Aileron/Elevator Mix This function is used to execute the mix of Rudder to Aileron/Elevator .It will help eliminate waver or shake caused by rudder stick operation. Rudder to Aileron... Press ENT to enter Main Menu. press UP or DN to make the navigation Elevator P05 0 LBfi I mark to choose “Function Menu". Press ENT to enter “Function Menu". then press UP or DN to choose ‘I‘Rudder to Aileron/Elevator-Mix" and Elevator Pos 0 Right press ENT to enter “Rudder to Aileron/Elevator Mix" setting interface. Setting method: 0% (1) Elevator setting (1.1) Elevator Pos 0 Leftward setting Press UP or DN to make the naVigation mark to select “Elevator Pos 0 Left setting" item. and press R or L to change the value and the Elevator mix amount when operating Rudder leftward .The mix direction Will be revised by changing the Sign of plus or minus before the value.The adjustable range is 1125%. (1.2) Elevator Pos 0 Rightward setting Press UP or DN to make the naVigation mark to select “Elevator Pos 0 Right setting" item. and press R or L to change the value and the Elevator mix amount when operating Rudder rightward .The mix direction will be revised by changing the sign of plus or minus before the value.The adjustable range is 112570. (1.3) Elevator Pos 1 setting: refer to “1.1 Elevator Pos 0" setting. (2) Aileron setting (2.1) Pos 0 setting: refer to “1.1 Elevator Pos 0"setting. (2.2) Pos 1 setting: refer to “1.1 Elevator Pos 0"setting. (3) Throttle stick setting The Switch between Pos 0 and Pos 1 can be realized by the position of Throttle Stick.then press R or L to change the value or Inhibit.Change the value to set the Thottle Stick position.The default setting is “Inhibit".the adjustable range is from 0.0 to 100.0%. (4) Switch setting The sWitch will display the current switch position. Press UP or UN to choose SWitch. press ENT to enter interface of Switch selection. press UP or DN to choose desired item. Press ENT to confirm. the desired item whose left side will be _ > changed into “1" from If Rudder toAileron... Iiii Swttch Iiii two or more items are Throttle Stick selected. the item And should be selected. whose left side Inh'b" © Flight Mode 0 should be changed into “1" SW‘tCh © Flight Mode 1 from “0". Press EXT after E Q) Flight Mode 2 finished it. DEVD 1 EE 763 JeUethion DEVD 4 2E Welcome to use the DEVO 12E transmitter 3.14 Flap System This function can modify some effects on elevator.lt is possible to set 3 status of elevator and 3 status of flap system,respectively.through 3rway flap control swtch. Setting method: Flap System nllll Press ENT to enter Main Menu ,press UP or DN to make the navigation Elevator 0: Normal I mark to choose “Function Menu“. press ENT to enter Function Menu. Press UP or DN to choose “Flap System" and then ENT to enter its setting interface Elevator 1: Midpoint 0% (1) Elevator setting There are 3 options:0:Normal:1 :Midpoint and 2:Land. (1.1) Elevator 0:Normal position Press UP or DN to make the navigation mark to choose “Elevator 0:Normal", and press R or L to change the elevator mix amount It is possible to change the direction by altering U or D before the amount. The default setting is 0%, and the adjustable range is U125% - D125%. (1.2) Midpoint pcsition:Please refer to “‘l .1 Elevator 0:Normal"setting (1.3) Land position: Please refer to “1 .1 Elevator 0:Normal"setting (2) Flap setting:the setting for flap is same as elevator. Flap System iiii (3) Status - .. .. Status Press UP or DN to make the navigation mark to choose Status , then Vibrating the flap switch(refer to 2.9 Device select) will display current m I ”WW" Throttle Stick lnhlblt (4) Auto land Flap System [W (4.1) Throttle stick setting Status . Press UP or DN to make the navigation mark to choose“Throttle stick" 0* Normal item. and press R or L to change value or Inhibit. It is possible to set Throttle Stick the position when changing the value.The default setting is “Inhibit“,and m ad)ustable range is from 0.0 to 100.0%. (4.2) Flight mode 0 setting It is possible to set a certain flight mode switch automaticly after automatic land.When do this, you must come to “Wing type" setting interface under the Model Menu and make correspond Wing type setting.Refer to 2.11 Wing type. Flap System a l I II Press UP or DN to make the navigation mark to choose “Flight mode Flight Mode 0 ()"item.and press R or L to 3 options: 0:Normal;’l:Midpointand 2:Land.lt is Mannul control when choose "Switch", but Automatic control when m choose Flight mode SWitch position. Flight Mode 1 Switch (4.3) Flight mode 1 setting:refer to "(4.2)Flight mode 0 setting" (4.4) Flight mode 2 setting: refer to “(4.2)F|ight mode 0 setting" (4.5) Flight mode 3 setting: refer to “(4.2)F|ight mode 0 setting" (4.6) Flight mode 4 setting: refer to “(4.2)F|ight mode 0 setting" Press EXT to exit after finished. DEVD 1 EE 7 EA oieUeniion DEVU 1 EE Welcome to use the DEVO 12E transmitter 3.15 Aileron to Flap Mix The function aims at mixing flap when operating aileron stick. and can set SWitch. The flap dual channels should also be previously activated at Wing Type in Mode Menu(refer to"2.11 Wing Type") Semng mew“ Aileron to Flap Mix Di... Press ENT to enter Main Menu ,press UP or DN to make the Post) Left I naVigation mark to choose “Function Menu", press ENT to enter Function Menu. Press UP or DN to choose “Aileron to Flap Mix" and then ENT to enter its setting interface. Pos 0 Right (1) Pos 0 to left setting 0 A) Press UP or UN to make navigation mark to select “Pos 0 to left setting",press R or L to change the leftward mix value ofAileron to Flapthe mix direction will be reVised by changing the sign of plus or minus before the value,the adjustable range is :125%. (2) Pos 0 to right setting press UP or DN to make navigation mark to select “Pos 0 to right setting“. press R or L to change the rightward mix value ofAilren to Flap, the mix direction Will be revised by changing the sign of plus or minus before the value.the adjustable range is 1125%. (3) Pos ‘l to left setting: refer above "(1) cos 0 to left setting" (4) Pos ‘l to right setting: refer above“(2) pos 0 to right setting" (5) Throttle stick setting The switch between Pos 0 and Pos 1 can be realized by setting the position of throttle stick. Press UP or DN to make navigation mark select "throttle slick setting". press R or L to change the value or inhabit. Change value can set throttle stick postion.The default setting is "inhabit". The adjustable range is from 0.0% to 100 0% (6) Switch setting The sWitch will display the current switch position. Press UP or DN to choose SWitch, press ENT to enter interface of SWItch selection, press UP or DN to choose desired item. Press ENT to confirm, the desired item whose left side will be changed into “1" from “0“. If two or more items are selected, the item And should be selected, whose left side should be changed into “1" from “0". Press EXT after finished it. Aileron to Flap Mix Throttle Stick Inhibit © Flight Mode 0 © Flight Mode 1 © Flight Mode 2 3.16 Pitch Curve Pitch Curve can be adjusted via seven points. Pitch Curves of Pos 0 and Pos 1 can be set, respectively. The item Pitch should be preVIously set in DeVIce Output at Model Menu (Refer to "2.10 DeVIce Output"). Setting method: Press ENT to enter Main Menu, Press UP or DN to move navigation mark to select Function Menu. Press ENT to enter Function Menu. Press UP or UN to select Pitch Curve, Press ENT to enter Pitch Curve interface. A dropdown menu with "All Servos Hold?" Will pop up. select Ok for locking all the current statuses of servos, and select Cancel for unlocking the current statuses. And the Pitch Curve "“l P'mh Curve ”ll“ interface will show the current Channel 499' 12D I used channel and the current All Servos Hold? position statuses of switches. m OK Cancel Position P05 0 Lt 2ivié it :1 DEVD 1 2E 785 JeUention Welcome to use the DEVO 12E transmitter DEVO 1 2E Pitch Curve — (1) Position selection Channel AUX2 Press UP or BM in the “Pitch Curve" setting interface to select Position “Position", press R or L to select the item you want to set in the list with Pos 0 and Pos 1. m L1 2M3 iii (2) Exponential setting Pl'Ch CUP/e :IIII Press UP or DN in the “Pitch Curve" setting interface to select Position “Exponential“ setting. Press R or L to set “0ft" or "On". Select On for Pos 0 smooth changes, and Off for changes in the form of fold ling in pitch Exponenjiai curve, respectively. - . _ d m:- h m“. (3) Curve setting Including “Point" and “Output (3.1) Point setting Press UP or BM in Pitch Curve interface to select Points setting. Press R to expand a list including seven pint-1", Point-3", 'and “PointeH'! Press Point ' - - Faint R or L to select the point you want to adjust. Pitch Curve Pitch Curve LiiMédH pjtch Curve (3.2) Status setting Pt— Press UP or DN to move navigation mark to Status and press R or 0‘” L to choose Inhibit or Active. Select Inhibit if keeping the current Point- 1 value(the default setting is Inhibit). Select Active tor changing the Status above points' value. m L) 2mm Note: After select point -L or Point-H, the status setting won't be display. (3.3) Output setting Pitch Curve Output Throttle Stick Inhibit There is a expand item “Output" after select Status Active, press UP or DN to select Output setting, press R or L to increase ordecrease, respectively, the output value. The adjustable range is HOW/u. LizMélfi I (4) Throttle Stick setting The swnch between Pos 1 and Pos 0 can be freely realized through throttle stick after the below amount has been set up. The below set amount is the position of throttle stick as well as the swrtch point. Pitch Curve Outpuj Throttle Stick setting: Press UP or DN to select Throttle Stick seting, -67“/ Press R or L to increase or decrease, respectively. The adjustable a range is from 0.0% to 100.0%. Choose Inhibit and the throttle stick Throttle Stick ! will not be set as a swnch. L1 2M3 Air DEVD 1 EE 7 SE
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 10 Producer : GPL Ghostscript 8.15 Create Date : 2014:04:15 15:23:32 Modify Date : 2014:04:15 15:23:32 Title : DEVO-12E manual 1.pdf Creator : PScript5.dll Version 5.2.2 Author : FrankEXIF Metadata provided by EXIF.tools