Tools needed to install your Switch
Slotted/Phillips Screwdriver Electrical Tape Pliers
Pencil Cutters Ruler
Line up tabs and
press in sides one
at a time to attach
Push in
side at tab
to release
Changing the color of your Switch:
Your switch includes three color options. The switch ships with the White
frame attached. To change color of frame, proceed as follows:
INSTALLING YOUR SWITCH
NOTE: Use check boxes when Steps are completed.
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power is off
before wiring!
Step 1
To rnillo Terminal
Rojo Marcado (RD)
BK
RD
YL/RD
4
3
2
1
To rnillo terminal Negro
marcado (BK)
To rnillo terminal Amarillo/Rojo
marcado (YL/RD)
Etiqueta terminal:
Sólo use esta terminal para
aplicaciones de 3-Vías o más.
Para aplicaciones unipolares,
no quite esta etiqueta.
Single Pole Wiring Application:
Step 4
• Makesurethattheendsofthewiresfromthewallboxare
straight (cut if necessary).
• Removeinsulationfromeachwireinthewallboxasshown.
• Single-PoleApplication,gotoStep4.
Step 3 Preparing and connecting wires:
5/8"
(1.6 cm) Strip Gage
(measure bare
wire here)
Cut
(if necessary)
Carga
Fase (Negro)
Línea
120 VCA, 60Hz
Neutro (Blanco)
Negro
Blanco
Verde
a tierra
Interruptor
Sólo use esta terminal para aplicaciones de 3-Vías o más.
Para aplicaciones unipolares no quite esta etiqueta.
BK
RD YL/RD
WH
Leviton’s Vizia RF +™ Z-Wave
®
components are designed to communicate
with each other via Radio Frequency (RF) to provide remote control of
your lighting. Using RF technology allows Leviton to provide the greatest
signal integrity possible. Each module in Leviton’s Vizia RF +™ component
line is a Z-Wave
®
enabled device. In a Z-Wave
®
network, each device is
designed to act as a router. These routers will re-transmit the RF signal
from one device to another until the intended device is reached. This
ensures that the signal is received by its intended device by routing the
signal around obstacles and radio dead spots. The Scene Capable Combo
Switch is compatible with any Z-Wave
®
enabled network, regardless of
the manufacturer and can also be used with other devices displaying the
Z-Wave
®
logo.
CAUTION:
Remember to exercise common sense when using the Timer features of
your Remote – especially when scheduling unattended devices. There
can be some unexpected consequences if not used with care. DO NOT
USE the remote for the control of high power heating appliances such
as portable heaters. This device will not control lighting that is used with
electronic low-voltage and high frequency power supply transformers, nor
high pressure discharge lamps (HID lighting). This includes mercury-vapor,
sodium vapor and metal halide lamps.
• SwitchON/OFF
• SceneCapable
• ON/OFFLED
• Twowaycommunication
• RFreliability
• Easeofinstallation–Nonewwiring
• CompatiblewithotherZ-Wave® enabled devices
FEATURES
INTRODUCTION
For non-standard wiring applications,
refer to Wire Nut and Connector Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIRE CONNECTOR / # OF COND. COMBINATION CHART
WIRING COMBO SWITCH:
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenswitchlead.
• LineHotwallboxwiretoBlackswitchlead.
• LineNeutralwallboxwiretoWhitedimmerlead.
• Load1wallboxwiretoRedswitchlead.
• Load2wallboxwiretoBlueswitchlead.
• Proceed to Step 5.
WARNINGS AND CAUTIONS:
• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.
• Ifyouareunsureaboutanypartoftheseinstructions,consultanelectrician.
• ViziaRF+™electroniccomboswitchesarenotcompatiblewithstandard3-wayor4-wayswitches.TheymustbeusedwithcompatibleViziaRF+™controllers.
WARNINGS AND CAUTIONS:
• Recommendedminimumwallboxdepthis2-1/2".
• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingxture.
• Usethisdeviceonlywithcopperorcoppercladwire.
DI-000-VRCS2-02A-X1-BETA
Identifying your wiring application (most common):
Step 2
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
1
5. Load
2
2
4
1
5
3
NOTE: If the wiring in your wall box does
notresembleanyofthesecongurations,
consultaqualiedelectrician.
• Restorepoweratcircuitbreakerorfuse.
• PresspaduntillocatorlightisOFF.Lights
shouldturnON.
If lights do not turn ON, refer to the
TROUBLESHOOTING section.
Testing your Switch prior to mounting
in wall box:
Step 5
• Positionallwirestoprovideroominoutletwallboxfordevice.
• Ensurethattheword“TOP”isfacingupondevicestrap.
• Partiallyscrewinmountingscrewsinwallboxmountingholes.
NOTE: Dress wires with a bend as shown in diagram in order to
relieve stress when mounting device.
Switch Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Step 6
Installation may now be completed by tightening
mounting screws into wall box. attach wallplate.
Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
Step 7
DI-000-VRCS2-02A-X1-BETA
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,
at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, N.Y. 11747. This warranty excludes and there is disclaimed liability for labor for
removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied
warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Programmer/Controller
Cat. No. VRCPG
NOTE: Programmer/Controller must be in close
proximity to switch when including in the network.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.viziarfplus.com
Protected under U.S. Patent Number 6,388,399 and patents pending
and licensed under U.S. Patents Numbers 5,905,442, and 5,982,103
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttofollowingtwo
conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation
of the device.
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigital
Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuseris
encouraged to try to correct the interference by one or more of the following measures:
• ReorientorrelocatethereceivingAntenna.
• Increasetheseparationbetweentheequipmentandthereceiver.
• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhich
the receiver is connected.
• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.
FCC CAUTION:AnychangesormodicationsnotexpresslyapprovedbyLeviton
Manufacturing Co., Inc., could void the user's authority to operate the equipment.
FCC COMPLIANCE STATEMENT
NOTE:ThelocatorlightwillilluminatewhentheloadisintheOFFposition
to facilitate access in the dark.
Push Pad (Default settings)
Turn ON from OFF position:
Tap–LightsturnON.
Turn OFF from ON position:
Tap–LightsturnOFF.
If there is a power outage, when the power is restored, the lights will return
to the last setting before the power interruption.
Cleaning: Clean with a damp cloth. DO NOT use chemical cleaners.
OPERATION
TROUBLESHOOTING
• LightsFlickering
- Lamp has a bad connection.
-
Wiresnotsecuredrmlywithwireconnectorsof
switch.
• LightdoesnotturnONandLocatorLEDdoesnotturnON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
• Remotedoesnotoperatelights
- Ensure that total wire length does not exceed 300 ft (90 m).
Step 9 Excluding Switch from Z-Wave® Network:
NOTE: It is very important to accurately Exclude devices from the network
when moving or removing a device from a Z-Wave® network. This ensures
that all information has been removed from your Primary Programmer/
Controller's information table and is not counted on to be part of the mesh
network.
A) If using a Leviton Z-Wave®Programmer/Controller,Cat.No.VRCPG,
press the Menu button and scroll down to System Setup. Press the
center button to select System Setup Menu. Choose Advanced Settings.
Press the center button to select Network.
B) While standing close to the switch (approximately 1 foot), press the
center button to <Exclude> device from the network.
C) While the Programmer/Controller is in the Exclusion mode and the
locatorLEDisONonthecomboswitch,pressthepushpadtoturn
on the switch. The Programmer/Controller will verify Exclusion and the
locatorLEDwillturnOFF.
If the switch is flashing Amber while in the Exclusion mode, the
Programmer/Controller is still trying to communicate with the switch.
Wait until the device stops flashing, then press the push pad.
Factory Default:
If your switch is not responding, or you are unable to control it after you have
tried to Include/Exclude it multiple times, it may be necessary to reset the
switch to its original factory settings. To accomplish this, proceed as follows:
• PressandholdbothbuttonsuntilthelocatorLED’sturnamber.LED’swill
continue to flash once every second. While standing close to the combo
switch (approximately 1 foot), press the center button to <Exclude>
device from network or primary remote.
CAUTION:SETTINGADEVICETOAFACTORYDEFAULTDOES
NOTEXCLUDETHATDEVICEFROMANETWORK.THEEXCLUSION
PROCEDUREMUSTSTILLBEFOLLOWEDTOREMOVETHEDEVICE
FROMTHEPRIMARYCONTROLLER’SINFORMATIONTABLE.FAILURE
TODOSOMAYRESULTINSYSTEMTHATISSLOWTORESPOND,OR
MAYFAILTORESPONDTOSOMEDEVICES.
Step 8 Including Combo Switch into Z-Wave® Network:
NOTES:
• Ifusinganon-LevitonProgrammer/Controller,refertothe
Programmer/Controller instruction sheet for Including a device.
• IfusingVRCPGinstallchecklistgodirectlytostepB.
A)
If using a Leviton Z-Wave®Programmer/Controller,Cat.No.VRCPG,
press the Menu button and scroll down to System Setup. Press
the center button to select System Setup Menu. Choose Advanced
Settings. Press the center button to select Network.
B) Press and hold both buttons until the locator LED’s turn amber.
Release buttons and locator LED’s should blink amber. LED’s will
continue to flash once every second.
C) While standing close to the combo switch (approximately 1 foot),
press the center button to <Include> device in the network. Device
will include as a controller.
NOTE:Thisistherststepoftheinclusionprocess.Onceyour
combo switch has been included as a controller, next include each
switch as a standard switch device following steps D-F below.
NOTE:Onlyonedevicemaybeincludedatatime.DO NOT put
multiple devices into the Inclusion mode at any time.
D) While the Programmer/Controller is in the Inclusion mode and the
LocatorLEDisONontheswitch,pressthepushpadtoturnon
the switch. The Programmer/Controller will verify inclusion and the
LocatorLEDwillturnOFF.
If the switch is flashing Amber while in the Inclusion mode, the
Programmer/Controller is still trying to communicate with the switch.
Wait until the device stops flashing, then press the push pad.
NOTE: If the Locator LED on the switch turns solid Red while
including, there has been a communication error. Refer to
Troubleshooting section.
E) The Primary Programmer/Controller will assign a node ID number
(Name) for each switch in the device.
NOTE: This ID number (Name) will be stored in the controller to be
used for future reference.
NOTE: You may name or edit your device at this time.
F) The switch is now installed in the network.
NOTE: If the switch has been successfully Included in the network
andtheusertriestoIncludeitagainwithoutrstexcludingitfromthe
network,theswitchwillretaintherstnodeIDithadreceivedandignore
the second.
1 ON
2 ON
3 ON
4 ON
OFF
OFF
OFF
OFF
Programmer/Controller
Cat. No. VRCPG
Menu
Button
Center
Button
© 2009 Leviton Mfg. Co., Inc.
Push Pads
Locator
Lights
Step 8 cont’d
ARTWORK PRINT SPECIFICATIONS
FOLD SCHEME / BINDERY DIAGRAM
PART NUMBER REV DESCRIPTION
Line Screen:
Angle:
Resolution:
Offset Flexo
Other
Body Material:
Bindery
Thickness:
Trim
Perfect Bind
Die cut Saddle Stitch
Drill
Fold
The information in this document is the exclusive PROPRIETARY property of LEVITON MANUFACTURING COMPANY, INC. It is disclosed
with the understanding that acceptance or review by the recipient constitues an undertaking by the recipient. (1) to hold this information in strict
confidence, and (2) not to disclose, duplicate, copy, modify or use the information for any pupose other than that for which disclosed.
© 2009 Leviton Mfg. Co., Inc.
Unpublished, All Rights Reserved
PlantApprovals:
ARN: Pilot Rev:ECO Number:
Artwork Release Date:
Artwork Print Specification Sheet Rev A04.eps
PMCQA
Artist:
Notes:
Other
Cust Other
S & A
Mktg Eng
FOR LEVITON USE ONLY
SPECIFICATIONS :
PROCESS :
MANUAL INTERIORS / BINDERY / FOLD SCHEME :
COMMENTS :
For manuals - designates cover specifications
Dimensions:
Material:
Thickness:
Finish:
:
Spot
CMYK
1:
4:
3:
2:
Color(s):over
1:
4:
3:
2:
Fonts:
Spot
CMYK
1:
4:
3:
2:
Color(s):over
1:
4:
3:
2:
Fonts:
Fold Line
Die Cut Punch/Drill Hole
Glue
Kiss Cut Cellophane
Fold Line
Perforate
Die Cut
Die Line Key:
2.3"
4.25"
14.0"
8.5"
Part No.
(This panel) Part No.
(This panel)
DI-000-VRSC2-02A-X1-BETA
8.5" x 14"
40 lb. BlackHelvetica
11
Instruction sheet
08 J. Tang
H. Sanchez
M. Crandall
B. Hamlitsch
P. Patel
A. Mancuso
V. LoNigro
1448

Navigation menu