Psion WLPC24H User Manual 2 install

Psion Inc 2 install

response to FCC correspondence 15472

Chapter 2: Installation Requirements
Maintenance
18 Teklogix 9150 Wireless Gateway User Manual
Refer to Chapter 7:Specifications” for a more detailed description of environmen-
tal requirements. Keep in mind that the long term stability of this equipment will
be enhanced if the environmental conditions are less severe than those listed in
this manual.
2.1.2 Maintenance
The 9150 has no internal option switches and does not require physical access; all
configuration settings are done remotely (see Chapter 3: “9150 Main Configura-
tion”). Environmental and radio communication considerations do still apply.
2.1.3 Power And Antenna Cables
To prevent accidental disconnection and stress on the 9150, antenna and power
cables should be secured within 30 cm of the unit. Secure the cables with ties to
the cable tie mounts on the 9150 (see Figure 2.1 on page 17). A single phase power
outlet (range 100 to 240 V A C r a t ed 1.0A mi ni mu m ) should be installed within one
metre (3.1 feet) of the 9150. The 9150 automatically adjusts to input within that
power range. The power cable is removable and is available in the power type spe-
cific to your location.
Warning: To avoid electric shock, the power cord protective grounding
conductor must always be connected to ground.
There are several omnidirectional antennas available from Teklogix. The type of
antenna required for each installation depends on the coverage requirements and
the frequencies used. Generally, a site survey determines the appropriate antenna.
Teklogix can also provide special, directional antennas. Consult Teklogix service
personnel for more information.
Warning: Equipment requires professional installation. The antennas
MobileMark model No. OD12-2400 and CONIFER Model
No. 26T-2400F are exclusively for fixed, point-to-point operation.
Installer is responsible for ensuring that the system is used for
fixed, point-to-point operation only. The maximum output power
from the radio transmitter is 15.2 dBm.
Teklogix 9150 Wireless Gateway User Manual 19
Chapter 2: Installation Requirements
Power And Antenna Cables
Warning: Never operate the 9150 without a suitable antenna or a dummy load.
Connection to Outdoor Antenna: Outdoor antenna to be earthed in
accordance with International Standard EN 50083-1 (1993),
“Cabled Distribution Systems for Television and Sound Signals -
Safety Requirements”. The antenna must be installed by a
qualified service person and installed according to local electrical
installation codes. The antenna should be located such that it is
always at least 20 cm away from the user and other people
working in the area.
Warning: For RF safety considerations, users are not allowed to approach
close to the antenna.
Teklogix supplies the coaxial cable required to connect the 9150 to the antenna.
When determining the location of the antenna, the coverage requirements
of the antenna are considered in conjunction with the environmental requirements of
the 9150.
The coaxial cable must be routed and secured using wire anchors and/or coaxial nail
clips. A few extra inches of cable are required near the antenna and the 9150 to
make disconnection easier.

Navigation menu