Japan Radio Co NKE2632 Solid State S-Band Marine Radar User Manual Installation Manual Part 3

Japan Radio Co Ltd. Solid State S-Band Marine Radar Installation Manual Part 3

Installation Manual Part 3

 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-30   2)  Install the Monitor Unit to the Display Unit Mount Kit with screws. Screws are attached to the Monitor Unit. Screw: M5x14SUS + Spring washer + Washer (included in CWA-245/CWA-246/CWB-1594/CWB-1595) Number of screw point: 26inch Monitor Unit(NWZ-208/NWZ-208-TP) - 10 points                       19inch Monitor Unit(NWZ-207/NWZ-207-TP) - 6 points   Do not install in a position to close the vents of the monitor.  In case of the 26inch Monitor Unit 3)  Remove the rear panel for wiring. Remove  4)  Insert the screw covers into the top and bottom spaces on the monitor.                     Monitor unit(26inch) NWZ-208/NWZ-208-TP         Monitor unit(19inch) NWZ-207/NWZ-207-TP Installation of Monitor Unit ends above.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-31   3.4.2   Installation of Operation Unit (NCE-5625/CWB-1593/NCE-5605) 3.4.2.1 Installation of Keyboard Operation Unit (NCE-5625) 1)  Remove the 4 screw covers from the KOPU-Keyboard Operation Unit by pushing the inside of the cover.   Do not remove the cover using a flat blade screwdriver. Because there is a possibility that the cover is damaged.   2)  Insert the W64: H-7ZCNA4187cable (included in the CMD-1106 in the NCE-5625) to the J642 connecter.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-32   3)  Install the KOPU to the Display Unit Mount Kit. Screw: M5x14SUS + Spring washer + Washer (included in CWA-245/CWA-246/CWB-1596)   4)  Insert the 4 screw covers into the original positions.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-33   3.4.2.2 Installation of Large Tray (CWB-1593) 1)  Remove the 4 screw covers from the Large Tray by pushing the inside of the cover.   Do not remove the cover using a flat blade screwdriver. Because there is a possibility that the cover is damaged.    2)  Install the Large Tray to the frame (CWA-245/CWA-246/CWB-1596). Screw: M5x14SUS + Spring washer + Washer (included in CWA-245/CWA-246/CWB-1596)  3)  Insert the 4 screw covers into the original positions.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-34   3.4.2.3 Installation of Trackball Operation Unit (NCE-5605) 1)  Connect the W61: H-7ZCNA4151(included in CML-901) with the TOPU-Trackball Operation Unit. After connecting, guide the cable in the groove.  2)  Remove the 2 screw covers from the TOPU.    Remove the screw covers by pushing the inside of the cover.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-35   3)  Install the TOPU bracket (MTV305174 included in TOPU) to the frame (CWA-245/CWA-246/CWB-1596).   Screw: NC3x8BS (included in CWA-245/CWA-246/CWB-1596)  4)  In case of installation of Keyboard Operation Unit. Connect the W64: H-7ZCNA4187 cable (connected with Chapter 3.4.2.1 Installation of Keyboard Operation Unit) to J614 connector on TOPU.  5)  Insert the TOPU as shown in the figure below. And Install the TOPU to the Frame. The W61: H-7ZCNA4151 cable through the hole in the bottom of the frame.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-36   3.4.3   Installation of Central Control Unit (NDC-1590) 1)  Remove the 4 screws of the front cover.    2)  Remove the 2 screws that hold the upper shelf, and remove the shelf. And then draw out forward and take out the upper shelf.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-37   3)  Install the CCU to the shelf. Refer to the figure below.   4)  Insert the shelf installed CCU. And screw the shelf to the frame.    Make sure the shelf is not floating.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-38   3.4.4   Installation of Power Supply Unit (NBD-913) 1)  Remove the 2 screws that hold the lower shelf, and remove the shelf. And then draw out forward and take out the lower shelf.   2)  Install the PSU-Power Supply Unit to the shelf. Refer to the figure below.   3)  Insert the shelf installed PSU. And screw the shelf to the Frame.    Make sure the shelf is not floating.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-39   3.4.5   Installation of Relay Terminal (CQD-2312) Attach the CQD-2312 Relay Terminal for distribute the AC/DC power. When the NQA-2443 Sensor LAN SW or UPS, has been arranged, install the SENSOR LAN SW and UPS before installing the Relay Terminal. For install the Relay Terminal, refer to the following procedure.  -3.5.3 Installation of Sensor LAN Unit -3.5.4 Installation of UPS  1)  Remove the 2 screws fixed to Display Unit Mount Kit(CWA-245/246). Refer to figure below for screw position.   2)  Fix the bracket for relay terminal mount(MTB409517) to Display Unit Mount Kit(CWA-245/246) use the screws removed in the previous section
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-40   3)  Attach the Relay terminal(H-7JTNA4061) to the DIN rail. Refer to figure below.   4)  Make sure that Relay terminal is fixed as shown in the figure below.  The installation of Relay terminal ends above
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-41   3.4.6   Connection of cables between unit 3.4.6.1 Wiring diagram OptionOption wiringStandard wiring NWZ-208MNUDVIRGB_inUSBRGB_outDC ACNDC-1590CCUJ4101DVI-MNUJ4118USB_TPJ4202SER-OPUJ4201USB-OPUJ4203RIFJ4204PSU-CONTJ4301PWR-PSUJ4205RGB-OUTNBD-913PSUJ53CONTJ52OUTJ51DC_SC OUTJ50AC_SC OUTNCE-5605TOPUNCE-5625KOPUNQE-1143JBJ831RIFJ8100DC24VJ601OPUJ614KOPUJ642KOPUJ8111LANJ839DCTB838AC MTRTB840DC MTRJ4117LAN1J4122LAN2J4115RADARNQA-2443Sensor LAN SWP90DC24VW71 7ZCNA4147W73 7ZCNA4149J8112LANW64 7ZCNA4187W61 7ZCNA4151W75 BSUABFC210IVW83KB-STP-01LB W53 7ZCNA4156AW51 7ZCNA4154W841 7ZCNA4164W853 7ZCNA4160W85 KB-STP-01LB J83748VW8517ZCNA4158ME-MAX-NEF/QUINT20AQUINT-BAT/24DC/3.4AHQUINT-DC-UPS/24DC/20QUINT-PS/1AC/24DC/20TB1AC DCJMR-9200 series wiring Fig 3-22: JMR-9200Series/JAN-9201/JAN-9202 Wiring Diagram OptionOption wiringStandard wiring NWZ-207MNUDVIRGB_inUSBRGB_outDCNDC-1590CCUJ4101DVI-MNUJ4118USB_TPJ4202SER-OPUJ4201USB-OPUJ4203RIFJ4204PSU-CONTJ4301PWR-PSUJ4205RGB-OUTNBD-913PSUJ53CONTJ52OUTJ51DC_SC OUTJ50AC_SC OUTNCE-5605TOPUNCE-5625KOPUNQE-1143JBJ831RIFJ8100DC24VJ601OPUJ614KOPUJ642KOPUJ8111LANJ839DCTB838AC MTRTB840DC MTRJ4117LAN1J4122LAN2J4115RADARNQA-2443Sensor LAN SWP90DC24VW71 7ZCNA4147W73 7ZCNA4149J8112LANW64 7ZCNA4187W61 7ZCNA4151W75 BSUABFC210IVW83KB-STP-01LB W53 7ZCNA4156AW51 7ZCNA4154W841 7ZCNA4164W853 7ZCNA4160W85 KB-STP-01LB J83748VW8517ZCNA4158ME-MAX-NEF/QUINT20AQUINT-BAT/24DC/3.4AHQUINT-DC-UPS/24DC/20QUINT-PS/1AC/24DC/20TB1AC DCJMR-7200 series wiring Fig 3-23: JMR-7200Series/JAN-7201/JAN-7202 Wiring Diagram
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-42   3.4.6.2 Wiring of standalone type 1)  Attach the cable tie base(ANP-1, ANP-2) and nylon clip (AB-10N) to the 12 position shown in the figure below. Cable tie base A B E Cable tie typeANP-1 20 20 7 T30RANP-2 25 30 8.2 T50R Fig 3-24:Cable tie base ANP-1 and ANP-2  ABCφDφD1ETScrewAB-10N 6.3 9.5 4.8 16 4.3 15.9 1.1 M4×10CableAB-10NCable tieM4X10BS Fig 3-25 Nylon Clip AB-10N Use the nylon clip as a clamp base. Refer to the above diagram.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-43                             Top of the right-hand side10ANP-2
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-44   2)  Connect the cable with the following procedure. ●For option wiring, refer to 3.5 Installation of Option Equipment.  W71:H-7ZCNA4147(included in CML-901)  Connect the DVI connector on the Monitor unit and the J4101 connector on the CCU with W71: H-7ZCNA4147 cable.  Be careful when connecting because it is easy to break the connection terminal of the DVI connector.   Wire the cable to pass through the nylon clip No.1 and the cable tie base No.9 and 11.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-45   3) W73:H-7ZCNA4149(included in CML-901)  Connect the DC power connector on the monitor unit and the P52 connector on the PSU with W73: H-7ZCNA4149 cable.  ●Wiring to DC power connector on the Monitor +: red(label: +24V) -: black(label:24VE) The polarities of the terminals are described near the connector.   The 26inch monitor unit DC power connector has 4 terminals. But only use pins No.2 and No.3.  Wire the cable to pass through the nylon clip No.4, 5 and the cable tie base No.10 and 12. Top of the right-hand side10ANP-2
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-46   4) W53:H-7ZCNA4156A(CML-901)  First, attach the ferrite core FL1:GTFC23-11-14 (included in CML-901) to the position shown in the figure above. After that, fix in the cable tie (included in CML-901). Second, Connect the J4301 connector on the CCU and the P52 connector on the PSU with the W53: H-7ZCNA4156A cable. Wire the cable to pass through the nylon clip No.5 and 6.            5) W51:H-7ZCNA4154(CML-901)  Connect the J4204 connector on the CCU and the P53 connector on the PSU with the W51: H-7ZCNA4154 cable.   Wire the cable to pass through the nylon clip No.4, 5 and 6.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-47   6) W61:H-7ZCNA4151(CML-901)  Connect the J601 connector on the TOPU and the J4201 connector on the CCU with the W61: H-7ZCNA4151 cable. TOPU J601 Connector  Wire the cable to pass through the nylon clip No.4 and the cable tie base No.10.              7) W90/91:H-7ZCNA4214(CML-901)  Connect the FG terminal of the CCU/PSU and the frame with the W90/W91: H-7ZCNA4214 cable. Y terminal  :Frame side Round terminal  :CCU/PSU FG terminal
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-48   8)  When installing touch panel unit(NWZ-208-TP, NWZ-207-TP) Connect the USB-B connector on the monitor unit and J4118 USB-A connector on the CCU with CML-839 W75:BSUABFC201IV cable.     Wire the cable to pass through the nylon clip No.1 and the cable tie base 9 and 11.  26inch touch panel monitor unit    19inch touch panel monitor unit
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-49   9)  Fasten the cable using the T30R/T50R cable tie to the cable tie base. ANP-1: Use the T30R ANP-2: Use the T50R AB-10N: No.1 – Use the T30R      No.4,5,6 – Use the T50R Use the nylon clip as a clamp base. Do not use through the cable. If installing the Option unit, should fasten the cable after installed the option unit. Be careful so that the cables are not stretched. Fold in the cable length is left over. Don't forget the screw lock of the connector H-7ZCNA4147/4149/4154/4156A, because these connectors are screw locking type connector.  10) Install the front cover and rear cover.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-50   3.4.6.3 Wiring of Desktop type 1)  Connect the cable with the following wiring diagram and procedure. ●For option wiring, refer to 3.5 Installation of Option Equipment.  W72:H-7ZCNA4148(CML-901-F)  Connect the DVI connector on the Monitor unit and the J4101 connector on the CCU with W71: H-7ZCNA4148 cable.    Be careful when connecting because it is easy to break the connection terminal of the DVI connector.   2) W74:H-7ZCNA4150(CML-901-F)  Connect the DC power connector on the Monitor unit and the P52 connector on the PSU with W74: H-7ZCNA4150 cable.  ●Wiring to DC power connector on the Monitor +: red(label: +24V) - : black(label:-24V)  The polarities of the terminals are described near the connector.   The 26inch monitor unit DC power connector has 4 terminals. But only use pins No.2 and No.3.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-51   3) W54:H-7ZCNA4157A(CML-901-F)  First, attach the ferrite core FL1:GTFC23-11-14 (included in CML-901-F) to the position shown in the figure above. After that, fix the ferrite core with cable tie (included in CML-901-F). Second, Connect the J4301 connector on the CCU and the P52 connector on the PSU with the W54: H-7ZCNA4157A cable.                      4) W52:H-7ZCNA4155(CML-901-F)   Connect the J4204 connector on the CCU and the P53 connector on the PSU with the W52: H-7ZCNA4155 cable.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-52   5) W62:H-7ZCNA4152(CML-901-F)  Connect the J601 connector on the TOPU and the J4201 connector on the CCU with the W62: H-7ZCNA4152 cable. TOPU J601 Connector  6)  When installing touch panel unit(NWZ-208-TP, NWZ-207-TP) Connect the USB-B connector on the monitor unit and J4118 USB-A connector on the CCU with CML-839 W75:BSUABFC201IV cable.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-53   3.4.7   Wiring for Relay Terminal CQD-2312 Relay Terminal distribute the AC/DC power to the each unit. Wire rod for distribute is attached to the Relay terminal. Process the cable. Refer to the following procedure.  3.4.7.1 Processing of wire rod 1)  NBD-913 Power Supply Unit – wire rod for AC power Cut the 2-core vinyl cab tire cable(VCT-2C-70/0.32) to length of the following. Remainder of this cable is not required. Please dispose it.   2)  NBD-913 Power Supply Unit – wire rod for DC power Cut the white vinyl cable(250V-HV-37/0.26(9)) and black vinyl cable(250V-HV-37/0.26-(0)) to length of the following.    Remainder of this cable to be used as AC/DC power cable for option unit(Serial LAN interface circuit, Sensor LAN SW, UPS). Process to cut so as not to waste. Do not dispose until all wiring is complete.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-54   When CMH-2370 Serial LAN interface circuit is arranged 3)  CMH-2370 Serial LAN interface circuit - wire rod for DC power   Cut the white vinyl cable(250V-HV-37/0.26(9)) and black vinyl cable(250V-HV-37/0.26-(0)) to length of the following. This cable is remainder of previous section.   Remainder of this cable to be used as AC/DC power cable for option unit(Serial LAN interface circuit, Sensor LAN SW, UPS). Process to cut so as not to waste. Do not dispose until all wiring is complete.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-55   When NQA-2443 SENSOR LAN SW is arranged 4)  CMH-2370 Serial LAN interface circuit - wire rod for DC power   Cut the white vinyl cable(250V-HV-37/0.26(9)) and black vinyl cable(250V-HV-37/0.26-(0)) to length of the following. This cable is remainder of previous section.   Remainder of this cable to be used as AC/DC power cable for option unit(Serial LAN interface circuit, Sensor LAN SW, UPS). Process to cut so as not to waste. Do not dispose until all wiring is complete.  In case of the 26inch Display Unit Mount Kit(CWA-246)   In case of the 19inch Display Unit Mount Kit(CWA-245)
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-56   When UPS is arranged 5)  UPS - wire rod for DC power output CMH-2370 Serial LAN interface circuit - wire rod for DC power   Cut the white vinyl cable(250V-HV-37/0.26(9)) and black vinyl cable(250V-HV-37/0.26-(0)) to length of the following. This cable is remainder of previous section   Remainder of this cable to be used as AC/DC power cable for option unit(Serial LAN interface circuit, Sensor LAN SW, UPS). Process to cut so as not to waste. Do not dispose until all wiring is complete.    6)  UPS - wire rod for AC power input Cut the 3-core vinyl cab tire cable cable(250V-HV-37/0.26(9)) and black vinyl cable(250V-HV-37/0.26-(0)) to length of the following. Crimp the crimp terminal to white cable at terminal block side. Remainder of this cable is not required. Please dispose it.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-57   3.4.7.2 Connection of Unit and Relay Terminal Connect Relay terminal and each unit(NBD-913 Power Supply Unit, CMH-2370 Serial LAN interface circuit, NQA-2443 SENSOR LAN SW, UPS). Use a wire obtained by processing in the previous section   CQD-2312 Relay Terminal Wiring diagram  1)  Wiring to the NBD-913 Power Supply Unit -  Wire the 2-core vinyl cab tire cable(VCT-2C-70/0.32) 550mm to the terminal block(TB1) L and N on NBD-913 Power Supply Unit.      L,U : White    N,V : Black  -  Wire the white vinyl cable(250V-HV-37/0.26(9)) and black vinyl cable(250V-HV-37/0.26-(0)) was cut to 700mm to the terminal block(TB1) + and – on NBD-913 Power Supply Unit.   + : White, - : Black  Wire the cable to pass through the nylon clip No.3.
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-58   2)  When NQA-2443 SENSOR LAN SW is arranged -  Refer to the 3.5.3 Installation of Sensor LAN Unit for procedure of the installation. -  Wire the white vinyl cable(250V-HV-37/0.26(9)) and black vinyl cable(250V-HV-37/0.26-(0)) to the terminal block(P90) + and – on NQA-2443 Power Supply Unit. + : White, - : Black  - Cable length CWA-245 19inch Display Unit Mount Kit - 500mm CWA-246 26inch Display Unit Mount Kit - 1200mm   When fix the cable, keep extra length so that there is no stress to terminal block(P90) for power supply to the NQA-2443 SENSOR LAN SW.  When 26inch Display Unit Mount Kit(CWA-246) is arranged -  Attach the cable tie base ANP-2 to the position of No.13, No.14, No.15 and No.16. And wire the cable. (Refer to figure below) -  Fix the power supply cable of NQA-2443 SENSOR LAN SW to the ANP-2    by use the cable tie;T50R   When 19inch Display Unit Mount Kit(CWA-245) is arranged -  Attach the cable tie base ANP-2 to the position of No.13. And wire the cable.(refer to figure below)
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-59   Wiring to the CQD-2312 Relay Terminal(Common in CWA-245 and CWA-246) At the terminal block side, wire the cable to the position surrounded by the circle in the figure below.     3)  When UPS is arranged -  Refer to the 3.5.4 Installation of UPS for procedure of the installation. -  Wire the 3-core vinyl cab tire cable cable(250V-HV-37/0.26(9)) 1000mm to the terminal block L,E and N on the ME-MAX-NEF/QUIT20. L : Red,    E : White,    N : Black -  Wire the white vinyl cable(250V-HV-37/0.26(9)) 900mm and black vinyl cable(250V-HV-37/0.26-(0)) 900mm to the output terminal block + and – on QUINT-DC-UPS/24DC/20. + : White    - : Black  -  Attach the cable tie base ANP-2 to the position of No.13 and No.14. And wire the cable.(refer to figure above)
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-60   -  At the terminal block side, wire the cable to the position surrounded by the circle in the figure below. AC-U : Red (VCT-3C-45/0.32) AC-V : Black (VCT-3C-45/0.32) DC+  : White (250V-HV-37/0.26-(9)) DC-  : Black(250V-HV-37/0.26-(0))    Fix the crimped white cable to the thumbscrew.(Refer to figure below)   Bottom view(Left hand side)
 3 Installation of Display Unit > 3.4 Installation of Standard Equipment 3-61   4)  When CMH-2370 Serial LAN interface circuit is arranged -  Refer to the 3.5.1.1 Installation of Serial LAN Interface Circuit (SLC) and 3.5.1.5 Installation of JB for procedure of the installation. -  Wire the white vinyl cable(250V-HV-37/0.26(9)) 700mm and black vinyl cable(250V-HV-37/0.26-(0)) 700mm to the terminal block(J8100) 24V+ and 24V GND on CMH-2370 Serial LAN interface circuit. 24V+ : White    24V GND : Black      When coil is attached to the CMH-2370 Serial LAN interface circuit, Refe to the 3.5.1.5 Installation of JB. And connect the power cable through the coil.  -  At the terminal block side, wire the cable to the position surrounded by the circle in the figure below. DC+ : White DC- : Black   procedure of the main power supply connection, refer to the 3.13 Initialization for the specified model Initialization for the specified model.    Before connecting the inboard power, please have finished all the necessary connections.
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-62   3.5   Installation of Option Equipment 3.5.1   Installation of Junction Box NQE-1143 Junction Box(JB) consists of interface boards that corresponds with the suffix. Type of JB is shown in the table below. The suffix is defined by the initials of the board from left when viewed from the front of the JB. Initials of the board not installing are omitted.      Therefore, the type of JB :「NQE-1143-SAGR」is shown that JB consists of SLC, AOC, GIF and RIF.
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-63   ■Installation Procedure Refer to the figure below. Skip the Installation procedure of the not installing board.    ■Board installing parts Install the boards using MPTG32506 attached to the JB frame.
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-64   3.5.1.1 Installation of Serial LAN Interface Circuit (SLC) 1) Install the SLC to the position shown in the figure below using the 5 pan head screws (BSNC03006B) from MPTG32506.  2) Install the shield case to the position shown in the figure below using the 4 pan head screws (BSNC03006B) from MPTG32506.   Shiled caseSLCShiled case2)1)PC810Pan head screwSLC
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-65   ●When installing the two SLC to a junction box 1)  Replace the hex spacer in JB shown in the figure below.   The hex spacer of the rightmost column is reuse.  2)  Install the SLC#2 to the position shown in the figure below using the 9 pan head screws (BSNC03006B) from MPTG32506.  ■Installation of the attachment of the SLC Note: If the coil with cable is not included, there is no need for the following procedure.  1) If the cable with coil in the figure below is included with the SLC,connect the coils to the P8100 terminal block plug on the SLC.  SLC  SLC#2
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-66   2) Fix the pair of coils to the cable tie base. Refer to figure for fixing the coil. In case of SLC#2, attach as well another pair.   3) Wire the cable, refer to wiring figure below.
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-67   3.5.1.2 Installation of Analog Option Circuit (AOC) 1)  Install the SLC(PC810) to the position shown in the figure below using the 5 pan head screws (BSNC03006B) from MPTG32506.  2)  Install the shield case to the position shown in the figure below using the 4 hex spacers (BRBP06403) from MPTG32506.  3)  Install the AOC(PC840) to the position shown in the figure below using the 4 pan head screws (BSNC03006B) from MPTG32506.   SLC AOC
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-68   3.5.1.3 Installation of Radar Interface Circuit (RIF) 1) Install the RIF(PC830) to the position shown in the figure below using the 6 pan head screws (BSNC03006B) from MPTG32506. Refer to Chapter 3.5.2 Connection of Display Unit and RIF for wiring.     RIF
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-69   3.5.1.4 Installation of Gyro Interface Circuit (GIF) 1)  If there is the SLC(Left), W82:FF12-10N046XXA FFC cable(included in CMJ-554) should connect to the J8115 connector on the SLC SS side. And lock the FFC connector.  Note insufficient insertion and inserted diagonally. Make sure that the FFC connector is locked.  2)  Install the GIF(PC820) to the position shown in the figure below using the 6 pan head screws (BSNC03006B) from MPTG32506.  3)  Connect the W82: FF12-10N046XXA FFC cable to the J821 connector on GIF. And lock the FFC connector.   Note insufficient insertion and inserted diagonally. Make sure that the FFC connector is locked.  4)  Connect the W81: CP010391-20 ribbon cable(included in CMJ-554) to the J822 connector on the GIF. And connect the W81 cable another end to the J835 connector on the RIF(PC830). AR1C1C10C11C12C14C15C16C17C18C19C2C200C201C202C21C22C23C24C25C26C27C28C29C3C30C32C34C35C36C37C38C39C41C42C43C44C45C46C47C48C49 C50 C51C52C53C54C55C56C57C58C60C61C62C63C64C65C66 C67C68C69C71C72C73C74C75C76C77 C78C79C8C80C81C82C83C9CD1CD10CD11CD12CD13CD14CD15CD16 CD17CD18CD19CD2CD25 CD26CD27CD3CD30CD32CD33CD34CD35CD36CD37CD38CD39CD4CD40CD42CD43CD44CD45CD46CD47CD5CD54CD59CD6CD7CD8CD9F1 F2 F3 F4FL1FL2FL3FL5FL6FL7FL8IC1IC10IC11IC13IC14IC15IC3IC4IC5IC6IC7IC8IC9J23J821J822J823MP1PHT2PHT3 PHT4PHT5 PHT6PHT7PHT8PHT9PS1R1R10R103R104R105R106R107R11R114R116R117R118R12R120R122R123R124R125R126R13R14R15R16R17R18R19R2R20R200R201R202R203R204R205R206R207R208R209R21R210R22R23R24R27R3R34R36R37R39R4R40R401R402R403R43R44R45R46R47R48R49R5R50R501R502R51R52R53R56 R57R58R59R6R60R61R62R63R64R65R66R67R68R69R7R70R71R72R73R74R75R76R77R78R79R8R80R81R82R83R84R85R86R87R88R89R9R90R91R92R93R94R95R96R97R98S1S2 S3S4TB1TB10TB19TB2TB3TB4TB401TB402TB403TP1TP10TP100TP11 TP12TP13TP14TP15TP16TP17TP18TP19TP2TP20 TP21TP22 TP23TP24 T P25TP26TP27TP28TP29 TP3TP30TP31TP32TP33TP34TP35TP36TP4TP5TP6TP7 TP8TR1TR4TR5TR6TR7TR8TR9XU1
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-70   3.5.1.5 Installation of JB 1)  Tighten the 2 screws(M5x10SUS + Spring washer + Washer) to the frame loosely.   2)  Hook the JB to the frame with the 2 screws.   3)  Install the JB to the frame.
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-71   4)  Connect the FG terminal of the JB to the frame. Y terminal  :Frame side Round terminal  :JB FG side    5)  If the SLC is installed to the JB, connect the 24VDC power supply line to the reference to the figure below.  ■If the coil and connection terminal is attached to the JB. There is a need to supply 24VDC through the coil. Please be wired to the following procedure. Step1: Crimp the 2 connection terminals (blue) to the DC power cable(24VDC line and GND). Connection terminals have been attached to the JB. If the second SLC is installed to the JB, crimp the connection terminal as well.     B W t L φd φD G H TOOL BODY No. DIES No.NA10NA3N10 12N3 12WIRE RANGEAWGSTRANDEDmm22.0 14.0NH12NH32TOOL No.TMEDN 630820-MA 6.35 10.3 0.8 22.0 2.55 4.5 6.4 10.0HAND TOOL No.DIMENSIONS mmPART NUMBER
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-72   Step2: Connect the connection terminal (crimped in step1) to the JB side connection terminal(red).  ●The polarity of the DC power cable of SLC +: white - : black   Step3: Please fix the DC power cable of SLC to the JB using the cable tie.    ■If the coil and connection terminal are included with the JB Please connect the DC24V supply line directly to the P8100. ●Terminal Assign of P8100 Terminal number 1:+24VDC (labeled with “24V”) Terminal number 2:GND (labeled with “GND”)
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-73   3.5.2   Connection of Display Unit and RIF 3.5.2.1 Connection for standalone type If the RIF is incorporated JB, connect the RIF and CCU. Either a cable is arranged by the scanner unit.  ・ CML-836-AC ・ CML-836-DC  ●When CML-836-AC has been arranged W841:H-7ZCNA4164(included in CML-836-AC) Connect the J831 connector on the RIF to the J4203 on CCU by W841: H-7ZCNA4164.  Wire the cable to pass through the nylon clip No.5 and 6.
 3 Installation of Display Unit > 3.5 Installation of Option Equipment 3-74   W851:7ZCNA4158(included in CML-836-AC) ・Connect the W851 cable connector labeled “P50” to the J50 connector on the PSU. ・Connect the cable labeled “P837” in the W851 cable to the J837 connector on the RIF.   ・Connect the terminal labeled “U” in the W851 to the TB838 U terminal on the RIF. ・Connect the terminal labeled “V” in the W851 to the TB838 V terminal on the RIF. ・Co-tighten the terminal labeled “FG” in the W851 cable and FG connection screw on the RIF.  Wire the cable to pass through the nylon clip No.6.  ●When CML-836-DC has been arranged   W841:H-7ZCNA4164(included in CML-836-DC) Connect the J831 connector on the RIF to the J4203 on CCU by W841: H-7ZCNA4164.  Wire the cable to pass through the nylon clip No.5 and 6.

Navigation menu